Analisis Fisikokimia Spektroskopi Inframerah Infrared (IR) Spectroscopy Harrizul Rivai HP. 081363049858 Email: harrizul@yahoo.co.id Bahan kuliah tersedia di: • http://redpoll.pharmacy.ualberta.ca • http://www.pharmacy.ualberta.ca/pharm325/ Spektrum Elektromagnetik Spektrum Elektromagnetik 106 106 109 1012 Radio 500 109 Microwave 200 1012 Infrared 1 Visible 10-3 1015 Ultraviolet l (nm) 1018 X-ray 1021 Cosmic Hz Jenis-jenis Inframerah (Infrared) • Near Infrared (Inframerah Dekat) – Panjang gelombang 1-3 mm – digunakan dalam analisis partikel • Middle Infrared (Inframerah Tengah) – Panjang gelombang 3-50 mm – digunakan terutama dalam karakterisasi senyawa organik • Far Infrared (Inframerah Jauh) – Panjang gelombang 50-1000 m m – tidak digunakan dalam analisis kimia Penggunaan IR dalam kehidupan sehari-hari Thermal Imaging (Thermography) Penggunaan IR dalam kehidupan sehari-hari Night Vision Goggles Spektroskopi Inframerah aspirin Prinsip-prinsip Spektroskopi IR • Spektroskopi IR mengukur energi panas atau energi termal dalam suatu molekul • Spektroskopi IR mengukur absorpsi cahaya yang disebabkan oleh vibrasi regangan atau tekukan ikatan dalam molekul. • Energi IR bersesuaian dengan energi regangan ikatan dalam molekul • Jenis ikatan yang berbeda menyerap pada energi (frekuensi) sinar IR yang berbeda Prinsip-prinsip Spektroskopi IR hn Energi Rendah Energi Tinggi Vibrasi molekuler • • • Posisi relatif suatu atom dengan atom lainnya dalam suatu molekul selalu berubah-ubah akibat dari gerakan vibrasi. Untuk molekul dwi-atom atau tri-atom, vibrasi berhubungan dengan energi absorbsi, namun tuk poliatom, vibrasi tidak mudah diperkirakan karena banyaknya pusat vibrasi yang berinteraksi. Vibrasi molekul ada 2: 1. Vibrasi ulur (stretching) 2. Vibrasi Tekuk (bending vibrations) scisoring (vibrasi gunting), rocking (vibrasi goyang), wagging (vibrasi kibasan) dan twisting (vibrasi pelintir). Vibrasi ulur (Stretching Vibration) Simetri (~ 2853 cm-1) Tak Simetri (~ 2926 cm-1) Pada vibrasi ini terjadi perubahan terus menerus dari jarak antara 2 atom di dalam suatu molekul (konstanta vibrasi antara dua atom sepanjang sumbu ikatan). Contoh : -CH3, -CH2-, -NO2, -NH2, dan anhidrida. Vibrasi Tekuk (bending vibration) • Terjadi perubahan sudut antara dua ikatan kimia. Ada 2 jenis vibrasi tekuk : a. Tekuk dalam bidang (in-plane bending) scissoring (gunting) dan rocking (goyang) b. Tekuk keluar bidang (out-of-plane bending) wagging (kibasan) dan twisting (pelintir) • Keempat vibrasi tersebut hanya mungkin bagi molekul yang memiliki lebih dari dua atom. (~ 720 cm-1) (~ 1450 cm-1) (~ 1250 cm-1) (~ 1250 cm-1) Jenis-jenis Vibrasi Molekular Symmetric Stretch Asymmetric Stretch Wagging Jenis-jenis Vibrasi Molekular Rocking Twisting Scissoring Simetric stretching Asimetric stretching Scissoring Wagging Rocking Twisting Vibrasi Khas IR UV vs. IR • IR has narrower peaks relative to UV • IR yields more information than UV • IR allows you to collect data on solids, liquids and gases • UV is more quantitative than IR • UV spectra are easier/faster to collect • UV samples are easier to prepare • UV spectrometers are cheaper Absorbance IR vs. UV 230 240 250 260 270 280 290 A Modern FTIR instrument FT = Fourier Transfrom FTIR Schematic 50% beamsplitter path “b” fixed mirror moving mirror path “a” a b x j- stop detector sample source IR Sample Preparation • Most flexible system for analyzing all 3 states of matter (solid, liquid, gas) • “Neat” (analysis of liquids/oils) • Pellet (analysis of solids) • Thin Cell (analysis of dissolved solid samples - solutions) • Long Cell (analysis of gases) Preparing a “Neat” IR Sample Preparing a KBr Disk Apparatus for KBr Disk Pressed Disk Preparation • Use powdered, dry KBr, KI, CsI • Mix reagent with KBr in 1:10 ratio • Grind material to 2 m diameter using agate mortar or vibrating ball mill (Wig-L-Bug amalgamator) • Place into die and press to 30 tons/in2 using hand press or wrench + nut • Remove carefully, handle with gloves IR Liquid Sample Cell IR Gas Sample “Cell” Analyzing IR Spectra • Look for C=O peak (1820-1660 cm-1) • If C=O check for OH (3400-2400 cm-1) – indicates carboxylic acid • If C=O check for NH (3500 cm-1) – indicates amide • If C=O check for C-O (1300-1000 cm-1) – indicates ester • If no OH, NH or C-O then ketone Analyzing IR Spectra • If no C=O check for OH (3600-3300 cm-1) – indicates alcohol • If no C=O check for NH (3500 cm-1) – indicates amine • If no C=O & no OH check C-O (1300 cm-1) – indicates ether • Look for C=C (1650-1450 cm-1) then aromatic IR Characteristic Vibrations Sample IR Spectrum #1 A - CO-OH stretch (3000) B - CH stretch (2800) C - C=O ester (1757) D - C=O carboxy (1690) E - C=C aromatic (1608) F - C=C aromatic (1460) Sample IR Spectrum #2 C B O C CH3 A Acetophenone A) C=O (1730) B) C=C aromatic (1590) C) C-H aromatic (3050) Applications • Qualitative “fingerprint” check for identification of drugs • Used for screening compounds and rapid identification of C=O groups • Can be used to characterize samples in solid states (creams and tablets) • Can detect different crystal isoforms (polymorphs) • Water content measurement Applications • Analysis of urine and other biofluids (urea, creatinine, protein) Applications • Used in non-invasive measurement of glucose Applications of Near IR (NIR) • Quality control of pharmaceutical formulations • Determination of particle size • Determination of blend uniformity • Determination or identification of polymorphic drugs