» » » » » Propeller Type Fan Size 100 – 400 MBH 80% Thermal Efficiency Natural or LP Gas 10 Year Warranty on Heat Exchanger, Burners, and Flue Collector » ODP Motors Standard, TE Optional » Adjustable Power Venter Assembly ˃ Allows Greater Venting Flexibility. Can be rotated up to 90 Degrees in Each Direction. » Heavy Duty Fan Guard ˃ OSHA Type Optional » Easy Access to High Limit Control and Pilot Access » All Controls are Accessible without Removing Side Jacket Panels » Same Components as the GHND/GHPD Except the Propeller Assembly is Replaced with a Centrifugal Blower Assembly » Size 100 - 400 MBH » 80% Thermal Efficiency » Belt Guard is Standard » Double Blowers with Single Shaft Utilized on Units Size 300 - 400 MBH » 4 Point Suspension » Blower Allows Unit to Handle Greater Static » Lower Operating Noise Separated Combustion Units » Propeller Style Unit Heater Designed for Dusty, Dirty, Mildly Corrosive Environments and Areas of High Humidity and Slight Negative Pressures » Separates the Unit’s Combustion Process from the Environment in Which the Unit is Installed by Taking Combustion Air from Outside the Contaminated Space » Sizes Ranging from 100 - 400 MBH » 80% Thermal Efficiency » 1 Year Warranty on Heat Exchangers, Burners and Flue Collectors » Power Venter Assembly Draws in the Outside Combustion Air and Discharges Flue Gas » Hinged Bottom Door Allows for Complete Access to Burners and Controls » Same Components as the GAND/GAPD Except the Propeller Assembly is Replaced with a Centrifugal Blower » Available in Sizes 100 - 400 MBH » 80% Thermal Efficiency » Belt Guard is Standard » 1 Year Warranty on Heat Exchanger, Burners and Flue Collector » Double Blowers with Single Shaft Utilized on Units Size 300 - 400 MBH » 4 Point Suspension » Blower allows unit to handle greater static » Lower Operating Noise Indoor Duct Furnaces Side Access Burner Drawer Sizes Ranging from 100 - 400 MBH 30 - 80 ° F Temperature Rise 80% Thermal Efficiency 409 Stainless Steel Heat Exchanger Recommended when Installed Downstream of Cooling Coil » High Limit Accessible Through Side of Unit. Located Below 4x4 Junction Box » 1 Year Warranty on Heat Exchanger, Burners, and Draft Diverter » » » » » Bottom Access Burner Drawer 30 - 80 ° F Temperature Rise 80% Efficient Same Features as Side Access Models Air Flow Baffle Required to Direct Air to the Bottom of Heat Exchanger Where the Highest Amount of Heat Transfer is Occurring » 1 Year Warranty on Heat Exchanger, Burners, and Draft Diverter » High Limit has Spring Loaded Assembly to Insure Contact with Heat Exchanger Header » » » » » » Same Components as the GAND/GAPD Except the Supply Air Fan is Removed from the Unit » Sizes Ranging from 100 to 400 MBH » 20 - 90 ° F Temperature Rise » 80% Thermal Efficiency. » 1 Year Warranty on Heat Exchanger, Burners, and Flue Collectors » 4 Point Suspension » Bottom Access Only to Burner Drawer » ETL Certified for Residential Garage Installations » Sizes Ranging from 30 to 120 MBH » Low Profile Design Ideal for Low Clearance Installations » Over 82% Thermal Efficiency » Heavy Duty OSHA Fan Guard » Single Burner Design » LED Diagnostic Control Board » Open Drip Proof Motor Standard » 10 Year Heat Exchanger Warranty » Field Convertible to Separated Combustion » Gas Conversion Kit Included » Sizes from 150 to 400 MBH » 83% Thermal efficiency » Interior Baffles Aid in Heat Transfer and Increase Outlet Velocity for Increased Throw Delivery » Isolated Control Panel for Service Convenience » Multiple In-Shot Burner Design » Direct Spark Ignition » Thermostat wires to an exterior terminal strip located under the control cabinet access door for ease of installation » Tubular Heat Exchanger for Long Life. » 10 Year Heat Exchanger Warranty » (19) Sizes 18 - 360 MBH » OSHA Fan Guard Standard on 18 – 48 MBH = Residential Certified » Available for use with Steam or Hot Water » Coil Connections on Top and Bottom of Unit » Coil Constructed of Copper Tubes with Aluminum Fins » Factory Tested at 200 PSI » Totally Enclosed Fan Motor Standard, Explosion Proof Motor Optional » 1 Year Warranty » » » » » » (4) Sizes 8 - 36 MBH Hot Water Only Coil Connections on Side of Unit OSHA Fan Guard is Standard Residential Certified Coil Constructed of Copper Tubes with Aluminum Fins » Factory Tested at 200 PSI » Totally Enclosed Fan Motor Standard, Explosion Proof Motor Optional » 1 Year Warranty » (15) Sizes 41-705 MBH » Available in Steam or Hot Water » Coil Connections on Top and Bottom of Unit » Copper Coil with Aluminum Fins Mechanically Bonded to the Tubes » Coils are Tested at 375 PSI » Threaded Steel Pipe Coil Connections » Totally Enclosed Fan Motor Standard, Explosion Proof Motor Optional » 1 Year Warranty » Model “GR” Option “G”– Gravity Vented Outdoor » Model “GR” Option “P”– Power Vented Outdoor » Model “GG” – Power Vented Indoor » Model “GX” – Separated Combustion Indoor » Model “AH” Air Handler » Consists of Individual Pre-Engineered Modules Arranged to Address Your Individual Applications » Trane GR Duct Furnaces are Available in Two Types. ˃ Standard Temperature Rise (20°- 60°F) ˃ High Temperature Rise (60°- 90°F) » GG/GX 30°- 80° Rise Only » Furnace Type Also Determines the Unit Access Side (Left or Right) Based on the Direction of Airflow Through the Unit. Duct Furnace Heat Exchangers are Available in 3 Types of Steel Aluminized Steel 409 Stainless Steel 321 Stainless Steel » Stainless Steel Packages: Provides a Total Package Protection by Including 409 SS Burners and Flue Collector » A Full Range of Gas Controls, Including: » Single Stage » Two Stage » Electronic Modulation ˃ Room Sensing ˃ Duct Sensing (W/, W/O Rm. O/R) ˃ Others, Including 4-20 mA & 0-10 VDC Controls and Multi-Furnace Staging » Factory Installed Coils ˃ ˃ ˃ ˃ Direct Expansion (DX) Chilled Water Steam Hot water » Draw Through Design Maximizes Coil Efficiencies » Full Size ASHRAE 62 Compliant Drain Pan » 4 Row & 6 Row, Single or Dual Circuit » Cooling Coil 1,000-6,300 CFM Range* » 3-30 Tons, But There is Flexibility. When in Doubt, Call! » Standard Left Hand Access, Right Hand Optional » Multiple Gas and Air Control Options » 1” Matte Face Insulation » Economizer Control Door Safety Interlock Ship Loose Parts List Totally Enclosed (TE) Premium Efficiency (PETE) » Open Drip Proof (ODP) » Premium Efficiency (PEODP) » Indicates ˃ Use of Outside and / or Return Air ˃ Use of an Air Hood (Shipped Separately) » Twenty Air Control Options Available » Options Range From Simple Two-Position Dampers (Open & Closed) to Various Modulating Controls to ASHRAE Cycles I, II & III » Other Options Available Including Enthalpy Controlled Economizer, Pressure Sensing & CO2 Monitoring » Refer the Catalog For Full Descriptions of the Air Control and Damper Arrangements » » » » » Low Leak Damper 409 SS Furnace Drip Pan High Altitude Derate Input Derate Evaporative Cooler ˃ 12” CELdek® Media ˃ 8” & 12“ GLASdek ® Media » » » » » Clogged Filter Switch Manual Blower Switch Firestat (Supply and / or Return) Freezestat (Time Delayed) Ambient Lockout » Interlock Relays (Specify Purpose) » Moisture Eliminators » Horizontal Return » Status Lamps » Double Wall Construction » Service Convenience Package » High / Low Gas Pressure Switch » Filters (TA, WA & Pleated) » Through the Base Utility Penetrations » » » » » » High Pressure Regulators Time Clocks GFI Convenience Outlet Thermostats DuctStats Disconnect Switches » Evaporative Cooler ˃ Fill & Drain Kit ˃ Freezestat » Remote Control Panel