Unidentified Gas

advertisement
Allocation of Unidentified Gas Statement
16th May 2011
Outline
• Introductions
• Presentation of the AUGS
• High level plan
• Consultations/presenting to industry
• Allocation of Unidentified Gas
• Understanding of the problem
• Proposed methodology
• Summary / Q&A
• Future Meetings
• AOB
What is GL?
GL is a world class technical
assurance and consulting company and
leading ship classification society.
Three business areas:
•Maritime Services
•Renewables – GL Garrad Hassan
•Oil And Gas – GL Noble Denton
GL Noble Denton - Our Heritage
Originally formed as the Research and
Development Group of British Gas
With the re-structuring of British Gas our
name changed to BG Technology and
acquired Transco Engineering Services &
Transco Technical Training in 1997
In 2001 we acquired Risx and Stoner
Associates Inc. and became Advantica
In 2007 Advantica was acquired by
Germanischer Lloyd
GL Noble Denton has become a leading global advisor
to the Oil & Gas industry
Oil & Gas assets
3,000 Employees in
35 Countries
Poland Russia
Kasachstan
Italy
MOPU
MODU
Norway
Offshore Structures
Pipelines
Trinidad
Peru
Brazil
Onshore Facilities
Tunisia
Libya
Egypt
Saudi Arabia
Kuwait
Subsea Installations
GL Noble Denton comprises experts from:
China
Korea
Thailand
Philippines
Vietnam
Singapore
UK
Germany
Canada
USA
Mexico
Oman
India
UAE Pakistan
Qatar
Malaysia
Iran
Bahrain
Brunei
Indonesia
Australia
Competencies along the whole asset life cycle
Technical Assurance
 Verification, Certification and
Classification
 Industrial Inspection
Advanced Engineering & Consulting
 Adv. Analysis & Eng. Consulting
 Field Development Planning
 Testing Services
 Asset Integrity Mgmt / Optimization
 Safety & Risk
 Software Solutions
Marine Consulting & Operations
 Marine Warranty
 Marine Consulting, Vetting &
Surveys, Marine Operations
 Marine Casualty Investigation
 Dynamic Positioning
Project Execution
 Project Management
 Design
 Transportation & Installation
 Due Diligence
 Construction Monitoring
Conflicts of Interest
• GL Noble Denton is independent of all UK industry bodies
• GL Noble Denton have not previously been involved with this particular unidentified
gas problem
• One of our core values is to be “the most respected international technical advisor
and trusted partner” for all our clients
• Our objectives are simple – to devise a methodology that is unbiased, meets the
requirements of the industry bodies and is approved by the UNCC
Overview of Project Plan
High Level Plan
Presenting to the UNCC
The AUGS covers
• Adherence to AUGE Guidelines terms of reference
• Proposed topics for unidentified gas and their status
• Data provision status/issues
• AUGE Methodology
•
•
•
•
•
Reasoning
Assumptions
Data Used
Issues/recommendations going forward
For incomplete aspects of the methodology (e.g. pending data) the AUGS contains details of
the remaining steps to complete it
• Consultation questions and responses as appropriate
Reporting Progress
• Primarily through the main UNCC presentations and publications of AUGS
• There is also visibility of activities from data requests and responses to consultation
questions
• In addition, brief progress reports will be provided via JO website
Consultations
Industry Bodies
issues/questions
Industry Bodies
issues/questions
GL Noble Denton
GL Noble Denton
present answers via
• AUGS
• Industry meetings
• JO website
• Collate
• Compare vs criteria
• Investigate / assess
• Generate responses
• Update methodology
• Update AUGS
Questions/issues can be raised via AUGE@gl-group.com
Unidentified Gas – The Problem
Unidentified Gas – Understanding of the Problem
The AUGE
• Robust and repeatable algorithm
• Estimates of Unidentified Gas that are
• Accurate
• Unbiased
• Unidentified Gas estimation is the core of the consultation/publication process
Unidentified Gas – Statement of the Problem
UK gas market sectors
• Daily Metered (DM)
• Non-Daily Metered Larger Supply Points (NDM LSP)
• Smaller Supply Points (SSP)
• Threshold between SSP and LSP is 73,200kWh pa
Unidentified Gas – Statement of the Problem
Additional factors:
• LDZ Shrinkage
• Leakage
• Own Use Gas
• Transporter-Responsible Theft
• Unidentified Gas
• Both unknown, both have to be estimated
Unidentified Gas – Statement of the Problem
Unidentified Gas
• Unregistered and Shipperless sites
• Independent Gas Transporter CSEP Setup and Registration Delays
• Corrections to the shrinkage estimate
• Shipper-responsible theft
• Potential additional sources of Unidentified Gas
• LDZ offtake meter errors
• Supply point meter errors
• These only apply if there is a long-term metering bias
Unidentified Gas – Statement of the Problem
Calculation of Unidentified Gas
• Understand process flow
• Location of UG at each stage of the calculation
• Calculate UG at optimal process stage
• Directly
• By subtraction
• Time frame covered by individual UG calculations
• Daily (aggregate results to annual level for UNC table)
• Monthly (aggregate results to annual level for UNC table)
• Annual
Unidentified Gas – Statement of the Problem
Previous UNC Modification Proposals
• 194/194A
• Gave framework for quantifying Unidentified Gas
• Relied on set percentages of RbD or set values
• 228/228A
• Populated framework with set percentages (228) or set values (228A)
• No provision for year-on-year updates at this stage
• Potential areas for improvement
• Both carry assumption that all or most of RbD is Unidentified Gas
• Recognition of allocation algorithm error
Unidentified Gas – Statement of the Problem
• The AUGE is independent and impartial
• Modification 229 allows UG estimates to be updated every year
• No UNC amendments required
• Estimates from the AUGE circulated and agreed prior to implementation
Unidentified Gas – The Solution
Unidentified Gas – The Solution
Daily Allocation Process
• Based on End User Categories
• Trained on metered data
• Minimum 3900 Small NDM, 1600 Large NDM supply points
• 2010 analysis actually used a total of 12715 supply points
• Estimates raw (metered demand) – i.e. no Unidentified Gas
• Scaled up to meet LDZ load (minus Shrinkage and DM load)
• Scaling process introduces Unidentified Gas
• Value unknown
• Split between EUCs by AQ
Unidentified Gas – The Solution
Composition of allocation estimate
• Actual EUC load
• Model error (can be positive or negative)
• Unidentified Gas (always positive)
• Each EUC total known, but composition unknown
Unidentified Gas – The Solution
Final calculation steps
• Aggregate to SSP and NDM LSP level
• SSP corresponds to one EUC
• NDM LSP is the sum of the remaining EUCs
• This is the basis for initial (deemed) load allocation
• Actual NDM LSP (monthly) meter reads become available
• Apply Reconciliation by Difference
•
•
•
•
NDM LSP load now accurate
Model error eliminated
SSP allocation is now actual SSP load plus Unidentified Gas
SSP/UG split unknown
Unidentified Gas – The Solution
Allocation Composition - Individual EUCs
350
300
TWh
250
200
150
100
50
0
1
2
3
4
5
6
7
8
9
EUC
EUC Load
Model Error + Unidentified Gas
Allocation Composition - Post RbD
350
300
300
250
250
200
200
TWh
TWh
Allocation Composition - By Sector
350
150
150
100
100
50
50
0
0
SSP
EUC Load
LSP NDM
Model Error + Unidentified Gas
SSP
LSP NDM
EUC Load
Unidentified Gas
Unidentified Gas – The Solution
Unidentified Gas Estimation
• Location known, UG accumulated into one figure
• Estimate should now be made
• Recommended approach – calculate each component directly
• Calculation granularity is part of analysis
Unidentified Gas – Individual Elements
Unidentified Gas – Data Requirements
•
•
•
•
•
•
Site AQs (for all DM, LSP and SSP sites)
Actual daily loads (DM sites)
Profiled daily loads (from meter reads for LSP NDM sites)
Deemed daily loads (LSP NDM and SSP sites)
RbD quantities
LDZ Shrinkage (calculated)
Plus data for
•
•
•
•
Unregistered and shipperless sites
IGT CSEP setup and registration delays
LDZ shrinkage initial and final estimates
Theft (including information on anti-theft initiatives)
Unidentified Gas – Unregistered/Shipperless Sites
• Unregistered Sites
• Opening meter reading taken when site is registered
• If this is not zero, Unregistered gas has been taken
• Shipperless Sites
•
•
•
•
Closing meter reading taken when site is unregistered
Opening meter reading taken when site is registered
If they differ, Shipperless gas has been taken
This gets assigned to SSP sector via RbD
• Potential impact of Mod 369
Unidentified Gas – Unregistered/Shipperless Sites
• Unregistered Sites – Shipper Activity/Orphaned
•
•
•
•
•
Data has been requested splitting these into “meter”/”no meter” categories
Determine proportion with meter that actually flow gas before they are registered
Analyse all opening meter readings to derive percentage non-zero
Apply this proportion to “meter” group
All sites in this group are more than 12 months old, hence unregistered consumption = AQ
• Unregistered Sites – Sites Created <12 Months
• Proportion flowing gas the same as for Shipper Activity/Orphaned sites
• Assume that rates of new sites getting MPRNs and sites with MPRNs becoming registered
are both steady
• Sites will, on average, have been taking gas for half the time period in question
• Report currently semi-monthly, hence average time taking gas is one month
Unidentified Gas – Unregistered/Shipperless Sites
• Shipperless Sites – Passed To Shipper
• Only sites visited after being shipperless for more than 12 months are reported
• More sites will have been shipperless for less than 12 months
- those flowing gas are still contributing to Unidentified Gas
• Relevant data requested from Xoserve
- all shipperless sites (including <12 months)
- all >12 month sites visited (not just those found to be flowing gas)
• Calculate “still flowing gas” rate from site visit data
• Apply to <12 month sites
• Carry out final calculation
- all >12 month sites in report have been flowing gas for full 12 months
- the <12 months sites still flowing gas will have been doing so for an average of 6 months
• Shipperless Sites – Shipper Specific Report
• Calculations as above
Unidentified Gas – Unregistered/Shipperless Sites
• No Activity
• Sites currently being processed
• These will end up in one of the other categories
• Split between those categories pro-rata before calculations carried out
• Legitimately Unregistered
• These sites are believed to have no meter
• Hence they do no contribute to Unidentified Gas
Unidentified Gas – IGT CSEP Registration Delays
• Within CSEPs, sites cannot take gas without being registered
• UG from this source comes from unregistered CSEPs only
• Entire network not registered on Xoserve system
• Regular meetings held with IGTs
• Report on statistics
• 32000 CSEPs
• Approximately 1200 are currently unregistered
• Down from 3000 in 2009
• Get average CSEP composition from known (registered) CSEPs
• Apply to unknown population to estimate consumption
Unidentified Gas – Shipper-Responsible Theft
• Data available for
• Detected theft
• Alleged theft
• These are high and low limits for true theft
• Two-yearly meter inspections ensure that unknown theft (ie theft that exists but has
never been alleged) is limited
• Changes in theft detection rates when shipper initiatives take place can be used to
estimate likely value of true theft between upper and lower limits
• It is recognised that true theft is very difficult to pinpoint
• Final value will be one agreed to be reasonable by all parties
Unidentified Gas – Shrinkage Error
• Difference between initial estimate and final estimate of shrinkage
• Can be positive or negative
• Shrinkage calculated as defined in UNC
• Most accurate models available are used
• National Leakage Tests
• Own Use Gas model
• Standard Theft assumptions
• Final shrinkage values recalculated after the event and RbD credited
• Hence error of initial (pre-year) estimate already accounted for in process
Unidentified Gas – Meter Error
Metering takes place
• At LDZ offtakes
• At Supply Meter Points
• DMs – daily
• NDM LSP – usually monthly
• SSP – less frequently
• Meter errors only have an impact over time if they carry a long term aggregate bias
• Potential effects can be positive or negative
• If present, this is a correction to RbD rather than Unidentified Gas
Unidentified Gas – Meter Error
• SSP meters use a rubber diaphragm
• These can warp over time
• They are set up to be unbiased on average over their 20-year lifespan
• SSP metering does not affect Unidentified Gas calculation anyway
• LSP and larger meters use metal components
• Regular maintenance
• No warping over time
• Therefore no long-term bias from this source
• Meter error can be discounted from analysis
• Backs up conclusions drawn in previous UNC Mods
Unidentified Gas – Unknown Sites
• Sites that are taking gas that
• Are not registered with a shipper
• Do not even have a MPRN
• These are unknown to the Xoserve system
• Data has been requested on this subject
Summary – Q/A
• Any other areas of UG to consider?
• Clarifications/Questions?
• Can raise further questions/issues post meeting via AUGE@gl-group.com
Thank you for your attention
Download