COLLEGE OF AGRICULTURAL ENGINEERING JAWAHARLAL NEHRU KRISHI VISHWA VIDYALAYA, JABALPUR TENDER NOTICE Sealed tenders are invited from manufacturers/Authorized dealers /Suppliers/Agents for supply of Laboratory, electronics, mechanical instruments, equipments, Workshop tools, Cooling device and audio video equipment etc. are invited for RKVY Project. Tender forms with details, terms and condition for supply can be down loaded from the JNKVV website www.jnkvv.nic.in. Last date of submission 05/01/2015 Dean Agricultural Engineering FACULTY OF AGRICULTURAL ENGINEERING JAWAHARLAL NEHRU KRISHI VISHWA VIDYALAYA, JABALPUR TENDER DOCUMENT TERMS & CONDITONS 1. Only the manufactures/authorized dealers/Publishers/Suppliers/Agents need submit the tender. The authorized dealers should furnish a copy of the current certificate from the Manufactures for their dealership. 2. No person or Firm shall submit more than one tender for the same item. 3. A broad-based specification of equipment is given in Annexure. The tenders should also take note of the remarks, if any given therein. 4. (a) Tender must be submitted in sealed cover to the Dean, College of Agricultural Engineering, JNKVV, Jabalpur-482004 (M.P.) by Registered post or delivered personally so as to reach on or before 05-01 /2015 by 3.00 PM (b) Belated tenders due to postal delay or any other reason will be rejected. (c) The tender in for EACH item should be sent SEPARATELY. The outer cover of the sealed envelope should be superscripted. ‘TENDER FOR AGRICULTURAL ENGINEERING (Name of the equipment with Serial No. ) 05-01-2015 due on (d) IF OFFERS FOR MORE THAN ONE ITEM ARE CLUBBED TOGETHER, THE TENDER WILL BE REJECTED. (e) The tender offers should have a validity of 90 days or more from the due date for the rates quoted. (f) The tender will be opened on 05-01-2015 at 3.30 PM in the office of the undersigned in the presence of the authorized representative of tenders. They should bring proper authority letters. (g) J.N. Krishi Vishwa Vidyalaya; reserve the right to extend the due date and or the date of opening the tenders. 5. The rate quoted should be for delivery at College of Agricultural Engineering, JNKVV, Jabalpur. The rate quoted should be inclusive of Packing and forwarding charges, loading/unloading/handling charges, freight full risk coverage, insurance installation charges etc. & the AMC charges for next two years from the date of installation of the supplied instruments/equipments. a) The price offered for individual items should invariably be in Indian Currency. The Firms are requested to convent the prices into Indian Rupees if they are offering goods. Prices for accessories if any are quoted separately. b) Excise duty, sales tax (with and without concessional certificate) VAT and other levees, if any, should be shown separately, and the total price of each item should be worked out incorporating the same. c) Any other charges, such as technical service charges, cost of training, installation charges etc. if any should be shown separately for each item and sub-item. d) Breakup of the prices for the main item and its sub-item should be given separately. This is necessary to workout prices of a desired configuration. 6. The tender should be accompanied by detailed printed technical literature, specification, make and model No. of each item and each sub-item quoted in the tender, otherwise offer shall be rejected. 7. If asked by JNKVV, the tenderer will have to arrange a demonstration of the equipments/system at JNKVV, Jabalpur without any charge of obligations. 8. All losses during transit will have to be made by the tenderer at his own cost within period of 15 days. 9. The tenderer must guarantee satisfactory functioning of the equipment/system and free service including free replacement of parts for a period of at-least one year from the successful and satisfactory installation of the equipment. 10. The tender must be accompanied by Earnest money deposit for each item, as mentioned in the form of crossed bank draft drawn on a nationalized bank, made infavour of J.N. Krishi Vishwa Vidyalaya, Jabalpur. Without the DD of earnest money deposit the offers are likely to be rejected. 11. (a) The standard terms and conditions of payment acceptable to JNKVV, are payment in full only after the contract is effected in full and to be satisfaction of JNKVV authorities. (b) In special cases, payment in advance or payment through a bank against the document or payment by opening irrevocable letter of credit with a bank or any other mode of payment may be considered by JNKVV provided in such cases the tenderer furnished as unconditional Bank Guarantee for the full amount to JNKVV with an agreement that in cases of any loss, incomplete supply, delay or breach of contract in any manner, the JNKVV can recover full amount from the supplier through this Bank Guarantee. (c) The tenderer should make it clear in the offer as to whether payment terms 11 (a) or 11 (b) both is acceptable to the tenderer else the tender offer is liable for rejection. 12. (a) If so desired by JNKVV, the tenderer shall have to enter into an agreement. (b) Any deviation, or non-compliance of the terms and conditions by the tenderer shall be considered as a breach of contract and JNKVV reserve the right to forfeit the amount of earnest money and or security deposit in part or in full and to take actions as per legal arrangement. 13. Should there arise any dispute, the Vice-Chancellor, JNKVV, Jabalpur shall be the sole Arbitrator, whose decision in the matter shall be final and binding. J.N.Krishi Vishwa Vidyalaya reserve the right to accept or reject any or all offers in full or in part without assigning any reason (s) therefore. It also reserves the right to place an order wholly or in part with one or more than one firm as they may be convenient to JNKVV. 14. The tenderer shall have to give an undertaking that the terms and conditions as mentioned above of this tender are acceptable to the tenderer. Note: The details of tender documents can be obtained in website http:www.jnkvv.nic.in. The tender document can also be downloaded from JNKVV website, which will be acceptable only deposited along with IPO/DD ₹ 500/- (Non refundable) in favour of Dean, College of Agricultural Engineering, JNKVV, Jabalpur payable at Jabalpur up to 05-01-2015 Dean Agricultural Engineering Department of Farm Machinery and Power Energy RKVY Project Specifications for different Items 1 Equipment / Approximate Specification Instrument required Lathe Machine 1. Size of machine (Length) = 7 feet Rs. EMD Rs 2. Width of bed, mm = 320-325mm 2000/ 3. Height of center mm= 267 mm 4. Spindle bore mm 54 minimum 5. Swing over bed, mm – 450-480 6. Swing over slide max 7. Admit between center = 900-1000 minimum 8. Equipped with Electric motor 2hp (company name), cluck different size, switches spanner, Elenkey set complete, clutch plate with appropriate cluck, center adopter, MT-3 /4,Dead center 2 No, 4 way tool post and key, change gear set for mm & Inch thread, steady & follow rest, and other accessories. 2 3. Spot welding machine Rs.500’ Shaping Machine Pedestal type spot welding machine, weldiability 34-14 SWG (0.23 to 2.003 mm) with all accessories. 1)Shaping machine (All Geared Type) Length of ram stroke: 660mm Rs.3000/ Length of ram: 1225mm Width of ram: 300mm Max. Distance from table to ram: 450mm Min. Distance from table to ram: 50mm Vertical travel of tool slide: 140mm Swiveling range to tool on either side: 60 degree Table size: 610 X 380 mm Horizontal travel of table : 600mm Vertical Travel of table:350 mm Nos. of speeds:4(With essential accessories) 4 Dynamometer (25 kw ) for testing engines of self propelled machines with accessories Computer based engine test rig for test of various engines used in self propelled agricultural machinery EMD Rs 10000/ Torque Measurement: With Load Cell, Output : 4 - 20 mA. Engine : 4 stroke diesel engine of 25 kW capacity, Dynamometer : The Engine is coupled with matching Eddy current dynamometer and capable to couple with 4 stroke diesel engine, 2 stroke petrol engine PƟ & PV Plot : i) Piezo Sensor : 1 No. for combustion pressure. ii) Spark Sensor : 1 No. iii) Piezo Amplifier : 1 No. iv) Crank angle sensor with TDC marker : 1 No. v) Temp. Transmitter : 6 Nos. with Sensors. vi) ADC Card : 1 No. with Complete Inter Facing. Software: A Powerful software for studying different characteristics of I.C. engine (diesel and petrol) e.g. Brake Power Vs Speed & Load, Heat Converted to Brake Power, heat goes to exhaust gasses & heat unaccounted. Computer: Intel core i5-2500 processor, 3.30 GHz, 6M cache, 4 cores/4 threads, Intel stable image platform program (SIPP), Chipset : Intel Q65 OEM mothercards,1, Memory: 2 GB 1066 Mhz DDR3 RAM with 8 GB expandability, Hard disk drive: 320 GB or more 7200 RPM Serial ATA HDD, Monitor: 18.5” wide TFT Digital color monitor, 104 Key boards, optical mouse, Windows 7 Professional pre-loaded, Preloaded software : Norton or McAfee or e Trust or e-scan or Quick Heal Antivirus (latest version), 3 years comprehensive H/W warranty, 6 USB ports etc. complete with HP Laserjet M1136 Printer Fuel Measuring Device: Fuel flow Sensor for fuel metering. Fuel tank mounted on sturdy iron stand, burette tube, three way cock, connecting tube & a stop clock. Calorimeter: Shell & Tube Heat Exchanger to measure the heat goes through exhaust gases. 5 Engine/machine eddy current /electronic/hydra 1. ulic/mechanical; (8-10 kw ) for testing engines of self propelled machines and farm machineries with accessories Rs 10000/ 2. Air Intake Measurement: Air Intake reservoir of size 0.3 x 0.3 x 0.5 m. with orifice plate, U-Tube manometer of 0.5 m height. With all set-up Specification sheet for 8-10 HP dynamometer Eddy current dynamometer (Water Cooled) Rated absorption Power = 6 KW / 8 HP or 13.4/10 HP Maximum torque = 70 Nm Maximum Torque at Speed = 1500 RPM Maximum speed = 12000 RPM Torque measurement precision = ± 0.25 FS%, 0.1 Nm resolution Speed measurement precision = ± 0.5 FS %, 1RPM resolution The direction of rotation both Clockwise & Anti Clockwise. Reaction type Torque Sensor to measure Torque, having 2 mV/V output. 60 - Tooth wheel with magnetic pick up sensor to measure speed. Torque calibrating arms. Magnetic heavy duty water strainer filter. Water flow switch MS Shaft guard, Openable with hinges. Dynamometer Controller PC Based Dynamometer Data Acquisition & Control system, Floor standing control panel PC Based Control Panel, consisting of: Dynamometer Control Circuit Constant Speed Mode – N. Constant Torque Mode – T. N / T Mode Selector switch. Interlock with Temp Sensor & Water Flow switch, Wiring, Terminals, connector, Mains isolator. PC based set up, PCI Card with necessary Digital & Analogue inputs & outputs, Engine TEST software developed using National Instruments LAB VIEW, Facility to View / Print observation table and save the acquired data of Torque (Nm) & Speed (RPM), Mechanical Power of Engine, Temp Measurement Data in Tables & Graphs for Torque Speed, Power - Speed, Power - Torque, Temp – Torque or Custom Curves, etc. in MS Excel format. Torque, Speed, HP/KW, All temperature parameters, would be displayed on monitor & stored in tabular & graph formats in MS Excel. Auto / Manual selector switch. (Manual Mode is redundant to Auto Mode. In case PC system for Auto mode fails, Dynamometer still can be operated in Manual mode) Manual Dynamometer controller with following controls: Load Potentiometer: 10 turn helical with dial to control Dynamometer in Manual Mode. Digital RPM Meter to read motor RPM, in Manual Mode. Digital Torque Meter calibrated to read Nm in Manual Mode. Digital Power Meter to read Engine Power in KW/ HP. SPAN, NULL & RESPONSE presets for Torque Indicator. PID Temperature Indicator Controller to indicate Engine Inlet & Outlet water Temperature. Oil Temperature, Dynamometer Water Outlet Temp (All 0 - 400ºC), Exhaust Gas Temp (0 - 1000ºC) – 5 Nos. Temp Indicators with Temp Sensors with PT 100 Type sensors. Annunciators to indicate Faults – Dynamometer Water High Temp, Engine Temp High, Oil High Temp, Low water flow. Tower Lamps for visual indication of System Start, Test Start & Systems Stop. 1. Cable loom with conduit of 15 Mtr length: Cable loom consist Shielded Control cables for Torque sensor, Speed sensor, Temp & Pressure sensors & Dynamometer Control, with Male-female round type connectors with flexible conduit of length of 15 Mtr. 4. Engine starting system: The Engine starting system is mounted on non drive end of Eddy Current Dynamometer. When operator presses Engine by START Push button, on control panel, the starter motor gets engaged with starting wheel, which rotates Engine to start. Once engine is started, START button should be released. Both Battery & Cables for Engine starting is included in the scope of supply. 5. Throttle Actuator: Normally engines are tested at different speeds. One end of the throttle actuator cable is connected to engine throttle point and another end of throttle cable is connected to throttle actuator. The throttle actuator is to be mounted near to engine. From control panel the operator can vary engine speed by turning throttle demand Potentiometer (i.e. 25%, 50% etc). Once Engine is started, the operator can increase or decrease the engine speed by potentiometer in Manual Mode, Where as Engine speed would be controlled thru software when system is in Auto mode. 6. Shut down actuator: The Engine would be turned off automatically by pressing Engine OFF switch on control panel. Pneumatic supply line of constant 5 Bar, 75 PSI pressure is to be connected to Engine shutdown actuator. When operator presses the shut down switch from control panel, the cable connected to engine via shut down actuator is pulled pneumatically from shut down actuator, which is mounted on stand near engine. 7. T’ slot bed for engine mounting with mechanical jacks: Length & Width is adjustable by T slotted fabricated bed & Height is adjusted by Mechanical jacks, with anti vibration pads, Cardan shaft between Engine & Dynamometer with Shaft guard, Engine mounting fixture, to mount Engine. 8. 6 Instran/ UTM Rs.5000/ 7. Data logger EmD: Rs 5000/ 8 9 10 Plate form type digital balance EMD Rs. 500 Weighing machine 1 kg EMD Rs 1000/ Digital Load cell with indicator EMD Rs. 2000 Gravimetric Fuel Consumption unit: A Specially designed High Speed & high accuracy load cell signal conditioning board directly provides digital readings for weight to the micro-controller. The programmed micro-controller then takes care of operating the solenoid valves to control the measurement processes. The Controller has facility of Digital Calibration by means of Key-pad and Display. All the Functions during Measurement, Fill-up or in case of any failure are taken care of by the Microcontroller of the instrument In-built Calibration facility. Maximum & minimum Fill-up level setting with weight of Fuel. High Accuracy Load Transmitter for sensing the weight. 4 ½ digit display for Measured Quantity with a resolution of 0.1 for weight & time and 1 for Revolution Digital Timer Display 4 digits for displaying the parameter being processed. Digital Display for selection of parameter. Digital display for showing current Flow rate. The Flow rate averaging time is user settable. This display is continuously updated during measurement being carried out. The Flow rate display has a Lease count of 1 gm/Sec Unique TARE & SET Calibration facility. 3 modes of operation are provided viz. Time Base, Quantity Base & Revolution Base. Overall Accuracy is within 0.3 % of selected Range. (1500 gm) Continuous measurement of average fuel consumption Capacity: 3 Kg/h. Instran/UTM Microprocessor based universal testing machine 10 Tonn capacity with pc, Printer and software. Complete with tension, compression & Transverse attachment (With essential accessories) Data logger having up to 8 to 15 output/inputs points/Channel. With the external storage device up to 10 GB. The data logger should be included with the various sensor of temperature having range 0 to more than 300OC, flow of water/liquid and air, humidity, speed/rpm, pressure of liquids/water, wind speed and another sensor to monitor the performance of biomass furnaces (0 to more than 15000C ) etc having high accuracy of measurement/sensing. The proposed sensor of the data logger should be operate from very small quantity of parameters to the large. The data logger should be easily interface to the computer in online mode or data collected in off line mode. Digital balance plate form type, capacity 200kg, least count Least count 0.001 gram 125 kg, 500 kg, 1 -, 4 tonne with Beam and diaphragm combination. Tension, compression and bi-directional options. Maximum error in axial force component measurement is limited to 0.25% within a 3° angle swept through 360° around the load cell axis. Its various end-fixing options are all inert and easily modified for direct inclusion in mechanical assemblies. Integral 4 to 20mA or ±10V output amplifiers can be fitted as an option. Other specifications Parameter Value Unit Non-linearity - Terminal ±0.05 % RL 11 Sound level meter EMD: Rs.3000/ Hysteresis ±0.05 % RL Creep - 20 minutes ±0.05 % AL Repeatability ±0.02 % RL Rated output - Rationalized 2.0 mV/V Rationalization tolerance (applies to single direction calibrations) ±0.1 % RL Output symmetry ±0.3 % AO Zero load output ±4 % RL Temperature effect on rated output per ºC ±0.002 % AL with capable rod ends and suitable for indicator as specification below: power source 6V sealed lead rechargeable battery bridged supply 5V dc fixed, calibration check internal shunt resistor, accuracy ±0.02 % Features: Precision Type 2 instrument, Measurement range: 30 to 140 dBa, Response modes: Fast, slow, Frequency weighting:, A, C, Displays SPL, Maximum SPL. Includes: WS-7 wind screen, 56-990 calibrator Adopter, 56-533 storage case.(With essential accessories) 12 Vibration Meter computerized human/ machine a) TECHNICAL SPECIFICATIONS: (1) S. NO 1 Mechanical vibration meter 4 Requirements Mechanical vibration meter with triaxial magnetic base piezoelectric accelerometer to measure vibration in three mutually perpendicular axis (X, Y and Z) Measurement of Acceleration, Velocity and Displacement Suitable for measurement of vibrations on Agricultural Machines Measuring range: 5 6 7 8 Acceleration – 0.03 to /10 mm/sec2 Velocity – 0.03 to 10mm/sec Displacement – 0.003 to / 10 mm Frequency Range : 9 10 11 12 14 Acceleration – 0.3 to 15 kHz Velocity – 0.3 to 15 kHz Displacement – 3 Hz to 1 kHz Display - 4 Digit, 7 Seg LCD at least 10 mm character Height Mode of Display - True RMS and equivalent peak for displacement, velocity and Accuracy - ± 2 % 15 Power supply 16 Calibration – Self Calibration Check & External Calibration clip EMD: Rs.10000/ 2 3 13 b) Triaxial Charge Accelerometer X 0.981 9.62 Y 1.007 Z 0.99 9 Axis pC/m s-2 Reference Sensitivity t 159.2 Hz 9.87 (w = 1000s’). 9.80 pC/g RMS AND 240C Lower Determined by the frequency limit amplifier used Upper frequency 12 12 12 kHz limit (+ 10%) Mounted 40 40 40 kHz Reson ance Frequency Transverse 3.4 3.6 1.6 % Sensitivity re reference Sensitivity (at 30 Hz, 100 ms-2) Transverse 14 14 14 kHz Resonance Frequency Resonance 34.1 34.4 32.7 kHz frequency Quality factor 352 349 9 @ f rse -2.1 -2.0 -2.1 %/de Amplitude c slope Measuring ± 10 kms-2 peak (± 1000 range : a peak) Max, operational stock Max. 5 kms-2 peak (500 g continuous peak) sinusoidal Electrical Capacitance of transducer (exc. Cable) 1000pF Insulation Resistance sensing elements > 20 Gohm Mechanical Case Material Titanium ASTM Grade 2 Sensing Element Piezoelectric, Type PZ 23 Construction Sealing Weight Electrical connectors Delta Shear Sealed 55 gram 3 x 10 – 32 UNF – 2A Mounting Thread 10-32 UNF -2B Mounting surface < 3 um Flatness Mounting Torque Max. 3.5 Nm Accessories:- Accelerometer cable, double screened for extra EMC protection. 13. Digital Cone Penetrometer EMD Rs. 2000 14 Harpenden Anthrop meter and skin fold caliper Technical Specifications for Digital Cone Penetrometer Meter with Data Logger with GPS Measuring Range: 0–18in (0–45 cm), 0–1,000 PSI (0–7,000 kPa) Measurement Units: Cone Index (PSI or kPa) Resolution: 1in (2.5 cm), 5 PSI (35 kPa) Accuracy: ± 0.5in (1.25 cm) Depth, ±15 PSI (103 kPa) Pressure Battery/Life: 4 AAA alkaline batteries; approximately 12-month life Display (Build-in GPS): GPS measurement system Numbers of Memory : 579 profiles with GPS Built-in data logger and RS-232 port allows Includes software and PC cable for data downloads Carrying case Direct and accurate reading to the nearest millimeter, range 50 to 570 mm, sliding member operating via miniature ball- bearing, carrying case, complete with straight and recurred branches, a spare counter and beam extension for the measuring of height up to 2 mtrs. EMD RS..1000/ 15 16 17 Ergo kit EMD Rs. 3000 Oxygen Consumption instruments EMD Rs. 4000 Pollard system for electro cardiac graphics and stationery Equipped with different accessories range 0.1 10 lit/min Vo2 Batteries , portable Multiple interfaces dual heart rate processing algorithms, 32 entry data history. (With essential accessories) The dynamics and stationery system of heart rate measurement equipment with computer analysis systems. EMD Rs 5000/ 18 Trade Mill EMD Rs .2000/ 0-12% elevation and 20 kmph speed and programmable. Technical data : motor-3 Hp continuous duty, Running surface- 150 x 50 cm, Running belt – 2 ply, Speed- 1- 20 km/h ( adjustable in increments of 0.1 km/h), Inclination- 0-12 % ( adjusted in 1% increments), Console : 19 Bicycle meter EMD Display – time, distance, speed, inclination, pace, calories, pulse, display of course profile with LCD, Training programs: 20, 4 direct selection buttons for speed. Features: Heart rate measurement, chest strap incl., PC interfaces. Extras: transport wheel ergo Manually programmable, inbuilt HR rate control programme, breaking power up to 600W, colour screen, inbuilt memory and performance test and computer and USB interface, class I safety features with international standard, weight less than 50 kg and carrying capacity 150 Kg Rs1000/ 20 Computerized human energy measurement system with telemetry EMD: Rs.10000/ Flow meter Flow range: Ventilation Range: Accuracy: Resolution: Gas Analyzer Type Range Response time: Accuracy: Gas Sampling Bi-directional digital turbine 28mm diameter 0-2 0-300 4 Oxygen GFC 7-24% 02 <120 msec per 90% FS 0.02% 02 Carbon Dioxide NDIR 0-8% CO2 <120 msec per 90% FS 0.01% CO2 Nafion Breath by Breath 21 Fuel consumption measurement Device With indicator EMD Rs 2000/ 22 Carbon pollution monitor EMD: Rs. 4000/ Rotary Torque Sensor with data logger 23 Type: Expired gas drying: Heart Rate Monitor Wireless double electrode (Polar) Transmitter and receiver Unit Memory: 16,000 breaths Display: LCD 2 lines x 16 characters Keyboard, Serial port/USB Thermometers: Barometers: Battery Type: Battery Autonomy: ~ 6 hours minimum Transmission distance: Minimum l000 m Note: The equipment should include the main unit with cables, 2 turbines, 3 face masks (S, M, L adult), 3 rechargeable batteries, 2 sampling lines, Polar heart rate belt, 2 head caps, user’s manual and adult harness Windows based system software c Measurement range 5 to 1000 ml, digital display, suitable to fit to fuel supply tube. Accuracy 1% it works for instant fuel consumption at any conditions. Measurement of CO, Co2 No, So2 etc levels for Indoor air quality monitoring (With essential accessories With sensors 100 Nm, 500Nm, 1000Nm, 1500Nm, least count 0.02 to 0.2 Nm, Data logger (with Strain soft software and PC based data logging in excel format) for 4 channels additional accessories like portable data logger 4 channel based battery Nafion RS 0-5 53-106 NI- 24 EMD: Rs.5000/ Torque pick up with indicator Rs.10000/ 25 Non – contact photo tachometers EMD : Rs 2000/ 26 Test rig for manually operated sprayers EMD Rs. 1000 operated(With essential accessories) Torque sensor: Torque sensor with non contact type data transmission, digital torque data (USB) up to 1000 Nm, Keyway shaft, rotational / static measurement, Bi-directional measurement, Battery operated, Calibration certificate, RS 232, Digital data, speed and power output Torque Indicator: Non Contact type digital indicator above torque sensor, operational temperature range 0 to 45 degree centigrade, battery life 12 hours, auto power off, RS 232 output, Rechargeable battery with battery charger, complete with all accessories, including mounting kit and carrying case. (With essential accessories) Photo tachometers Specification: Range (rpm): 5 to 99,999, Accuracy: ± (0.05% rdg + 1d), Sampling Time: 1 sec> 60 rpm, Resolution: 0.1 rpm (0.5 to 999.9 rpm); 1 rpm (>1000rpm), Features: Large 5 digit LCD display is easy to read Built-in memory recalls last MAX/MIN value stored, Auto ranging with 0.05% accuracy, Non contact measurements from 5 to 99,999 rpm, User reflective marker on object to be measured and integral light beam or accurate readings updated point every second, 2 to 6 inches (50 to 150 mm) measurement distance (depending on ambient light) Complete with 23” reflective tape, four AA batteries and case(With essential accessories) This system is designed to conduct performance testing of manually operated sprayers as per IS 10134-1994 facility of testing. Stirrup type sprayer. Foot and Rocker sprayer and Knap sack sprayer. Auto miser sprayer .By changing the drive linkage mechanism is provided alternately. DESCRIPTION & SPECIFICATION.:1) Strong and sturdy fabricated frame structure made out of M.S channels and plates to give sufficient rigidity to the machine. 2) Drive motor 2 H.P, 1440 RPM coupled with warm reduction gear box 20:1 ratio to provide drive to the test sprayer. 3) Adjustable eccentric mechanism fitted on gear box out put shaft with max. Stroke adjustment up to 150 mm. 4) Adjustable linkage with ball joints and guide bushes suitable for transferring rotary motion motor to oscillating one of sprayer handle. 5) Discharge collecting pipe 6 mm ID and @ 800 mm length provided with pressure gauge, pressure regulator and @ 2 m of flexible pipe for connecting to pump discharge port and sump tank. 6) Digital flow rate timer to measure collective discharge of test sprayer for one minute with return valve to sump tank. Range: - 0 - 5 LPM. 7) Electrical panel comprises ofi) A.C. variable speed drive for 5 H.P motor. Other electrical accessories such as contactors, push buttons, MCB etc. 27 Test rig for This system is designed to conduct performance and endurance testing of hydraulic power operated power sprayers as per IS 11313:2007 facility of testing. sprayers EMD Rs. 1000 DESCRIPTION & SPECIFICATION.:- 28 Spectrometer EMD Rs. 10000 8) Strong and sturdy fabricated frame structure made out of M.S channels and plates to give sufficient rigidity to the machine. 9) Drive motor 2 H.P, 1440 RPM coupled with warm reduction gear box 20:1 ratio to provide drive to the test sprayer.3)The drive motor is mounted on swinging filed dynamometer so that torque consumed is indicated on the panel suitable flexible coupling attachment is provided for connecting this motor to test pump.4) Discharge collecting pipe 10 mm ID and @ 800 mm length provided with pressure gauge, pressure regulator and @ 2 m of flexible pipe for connecting to pump discharge port and sump tank.5)Digital flow rate timer to measure collective discharge of test sprayer for one minute with return valve to sump tank. Range: - 0 - 10 LPM.6)Electrical panel comprises ofii) A.C. variable speed drive for 5 H.P motor, Digital torque indicator. Range: - 0 - 20 N-m., Digital Pressure iii) indicator.Range: - 0 -10 kg/cm2 I 3)Digital preset timer.Range: -0 - 99.9 hrs. ii)Other electrical accessories such as contactors, push buttons, MCB etc. Specifications Spark System o o o o 29 30 31 Crane scale EMD Rs 1000/ 10 hp Dc motor along with control panel EMD Rs 2000/ Multimedia I-station RS 2000/. Easily accessible sample stand Designed for easy cleaning Argon Flushed Tungsten electrode Software Operation o User friendly menu driven software o Factory calibrated o User configurable alloy standardization o Facility of delete bad RUNS o Display of mean and SD/RSD o Pot report generating facility Electrical Requirements o 170 to 270 VAC, 50 Hz o In built voltage stabilizer Control and Data Processing o Contains built in Pentium PC o Windows XP/7/8 (all versions) based Software o Portable Pen Ram Drive o USB Port Source o Regulated excitation source o Fully computer controlled Unipolar discharge Capacity: 3 ton, Accuracy 1 kg, (With essential accessories) 10 HP dc MOTOR WITH VARIAC , Volt , Ampare, RPM Regulators/control panel/1500 rpm/ 220 volt/440 armature and switches etc. Wireless microphone : Frequency range : 740MHz ̴752 MHz , RF Output: 10 mW Speaker : 2x 60 W speaker with woofers and tweeters, , Frequency range: 40 Hz ̴ 20 KHz, output 60 W RPM/ 160 W peak, weight 3.5 Kg. Gooseneck microphone: Frequency response : 150 Hz ̴ 17 KHz, Software: Description: Electric lecturer stand/ electric board KPS S/W using for class and presentation, Operation system: Microsoft windows 2000, windows XP, Windows XP, Windows Vista, Windows 7/8; Hard disk: Over 160 GB. 33 Cutting force measurement device for field crops Disc: 40 cm, blade mounting device, blade set with varying angles, Control panel with VFD for RPM optimization, motor 1 hp. EMD. Rs 3000/ 34 Operational sound reinforcement solution This is an attractive public address podium that features an all in one design. It has a built-in 60 Amplifier, 60 W column speaker with one tweeter and three woofers. Flexible gooseneck microphone and lamp are provided as well. Number of input and output connections make it easy to expand its capacity. Available in white or black finish, wooden top and steel bottom; goose neck MIC .EMD Rs. 3000/ 35 Cooling device Rs.3000/ 1.5 ton split type Air conditioner with fitting and stabilizers (including installation) Power: 5-star rating 36 Tractor 35-40 hp General specifications EMD: Rs. 5000/ HP Category -35-40 HP Type – 4 stroke, Direct injection, Diesel engine No. of cylinders – 3 Bore and stroke – 100 x 116 mm Displacement – 2734 cc Rated Engine speed – 1800 rev/min Air cleaner – 3-stage oil bath type Cooling system – water cooled with no loss tank Transmission Clutch – standard, single dry disc friction plate – 280 mm dia. 11” Optional No of gears – 8 forward, 2 reverse speeds PTO Speed- Standard-1000 rpm Optional – 540 rpm Tyres – Standard Brake type - Standard - Dry Disc type Brakes Optional - Oil Immersed Brakes Steering type -Standard - Mechanical Steering with Heavy Duty single drop arm for better maneuverability & comfort to operator Hydraulics - Live Hydraulics • Position control: To hold lower links at any desired height • Automatic draft control: To maintain uniform draft • Mix Control: For optimum field output Lifting Capacity - Standard 3 point linkage Category-I suitable for Category-II type implement pins. 37 Notebook/ Laptop EMD=1,000/- Notebook OS Operating system Windows 8.1 64 bit PROCESSOR Processor Intel® Core™ i5-4210U with Intel HD Graphics 4400 (1.7 GHz, 3 MB cache, 2 cores) MEMORY Memory, standard 4 GB 1600 MHz, DDR3L SDRAM (1 x 4 GB) STORAGE Hard drive description 1 TB 5400, rpm SATA GRAPHICS Graphics Intel HD Graphics 4400 DISPLAY Display 13.3" diagonal HD anti-glare WLED-backlit (1366 x 768) Display size (diagonal) 13.3" CONNECTIVITY Wireless 802.11b/g/n (1x1) and Bluetooth® 4.0 combo Expansion slots 1 multi-format SD media card reader Network interface Integrated 10/100 BASE-T Ethernet LAN PORTS/SLOTS Ports 2 USB 3.0; 1 USB 2.0; 1 HDMI; 1 RJ-45; 1 headphone/microphone combo INPUT Webcam TrueVision HD Webcam (front-facing) with integrated dual array digital microphone Keyboard Full-size island-style keyboard Pointing device Imagepad with multi-touch gesture support AUDIO Audio features BeatsAudio™ with 2 speakers POWER Power supply type 65 W EM AC power adapter Battery type 3-cell, 43.5 Wh Li-ion SECURITY Security management Kensington MicroSaver lock slot; Power-on password; Accepts third-party security lock devices WARRANTY Warranty 1-year on-site Terms and Condition: Taxes Transportation Other charges SUCH AS OCTROI, INSURANCES, INSTALLATION, MOUNTING , WIRING, COMMISSIONING ETC WILL BE DONE BY THE SUPPLIER TIN /PAN NO. Validity Delivery Warranty Mode of Payment FOR Please give the following details After delivery and successful installation JABALPUR, M.P. Details of Registration of the firm Details of location of the firm & its service centres Enclosure No. Enclosure NO. Details of after sales service where ever applicable Enclosure NO. Documentary evidence of being an authorized representative/supplier and dealer Catalogues showing the technological core competence Details of EMD Details of some esteemed customers and their testimonials Any other document as may be necessary as per tender Enclosure NO. Enclosure NO. Enclosure NO. Enclosure NO. Enclosure NO.