10 HP dc MOTOR WITH VARIAC , Volt , Ampare

advertisement
COLLEGE OF AGRICULTURAL ENGINEERING
JAWAHARLAL NEHRU KRISHI VISHWA VIDYALAYA, JABALPUR
TENDER NOTICE
Sealed tenders are invited from manufacturers/Authorized dealers /Suppliers/Agents for
supply of Laboratory, electronics, mechanical instruments, equipments, Workshop tools, Cooling device
and audio video equipment etc. are invited for RKVY Project. Tender forms with details, terms and
condition for supply can be down loaded from the JNKVV website www.jnkvv.nic.in. Last date of
submission 05/01/2015
Dean
Agricultural Engineering
FACULTY OF AGRICULTURAL ENGINEERING
JAWAHARLAL NEHRU KRISHI VISHWA VIDYALAYA, JABALPUR
TENDER DOCUMENT
TERMS & CONDITONS
1. Only the manufactures/authorized dealers/Publishers/Suppliers/Agents need submit the
tender. The authorized dealers should furnish a copy of the current certificate from the
Manufactures for their dealership.
2. No person or Firm shall submit more than one tender for the same item.
3. A broad-based specification of equipment is given in Annexure. The tenders should also take
note of the remarks, if any given therein.
4.
(a) Tender must be submitted in sealed cover to the Dean, College of Agricultural
Engineering, JNKVV, Jabalpur-482004 (M.P.) by Registered post or delivered
personally so as to reach on or before 05-01 /2015 by 3.00 PM
(b) Belated tenders due to postal delay or any other reason will be rejected.
(c) The tender in for EACH item should be sent SEPARATELY. The outer cover of the
sealed envelope should be superscripted. ‘TENDER FOR AGRICULTURAL
ENGINEERING (Name of the equipment with Serial No. ) 05-01-2015 due on
(d) IF OFFERS FOR MORE THAN ONE ITEM ARE CLUBBED TOGETHER, THE TENDER WILL
BE REJECTED.
(e) The tender offers should have a validity of 90 days or more from the due date for
the rates quoted.
(f) The tender will be opened on 05-01-2015 at 3.30 PM in the office of the
undersigned in the presence of the authorized representative of tenders. They
should bring proper authority letters.
(g) J.N. Krishi Vishwa Vidyalaya; reserve the right to extend the due date and or the
date of opening the tenders.
5. The rate quoted should be for delivery at College of Agricultural Engineering, JNKVV,
Jabalpur. The rate quoted should be inclusive of Packing and forwarding charges,
loading/unloading/handling charges, freight full risk coverage, insurance installation charges
etc. & the AMC charges for next two years from the date of installation of the supplied
instruments/equipments.
a) The price offered for individual items should invariably be in Indian Currency. The Firms are
requested to convent the prices into Indian Rupees if they are offering goods. Prices for
accessories if any are quoted separately.
b) Excise duty, sales tax (with and without concessional certificate) VAT and other levees, if
any, should be shown separately, and the total price of each item should be worked out
incorporating the same.
c) Any other charges, such as technical service charges, cost of training, installation charges
etc. if any should be shown separately for each item and sub-item.
d) Breakup of the prices for the main item and its sub-item should be given separately. This is
necessary to workout prices of a desired configuration.
6. The tender should be accompanied by detailed printed technical literature, specification,
make and model No. of each item and each sub-item quoted in the tender, otherwise offer
shall be rejected.
7. If asked by JNKVV, the tenderer will have to arrange a demonstration of the
equipments/system at JNKVV, Jabalpur without any charge of obligations.
8. All losses during transit will have to be made by the tenderer at his own cost within period of
15 days.
9. The tenderer must guarantee satisfactory functioning of the equipment/system and free
service including free replacement of parts for a period of at-least one year from the
successful and satisfactory installation of the equipment.
10. The tender must be accompanied by Earnest money deposit for each item, as mentioned in
the form of crossed bank draft drawn on a nationalized bank, made infavour of J.N. Krishi
Vishwa Vidyalaya, Jabalpur. Without the DD of earnest money deposit the offers are likely to
be rejected.
11.
(a) The standard terms and conditions of payment acceptable to JNKVV, are payment
in full only after the contract is effected in full and to be satisfaction of JNKVV
authorities.
(b) In special cases, payment in advance or payment through a bank against the
document or payment by opening irrevocable letter of credit with a bank or any
other mode of payment may be considered by JNKVV provided in such cases the
tenderer furnished as unconditional Bank Guarantee for the full amount to JNKVV
with an agreement that in cases of any loss, incomplete supply, delay or breach of
contract in any manner, the JNKVV can recover full amount from the supplier
through this Bank Guarantee.
(c) The tenderer should make it clear in the offer as to whether payment terms 11 (a) or
11 (b) both is acceptable to the tenderer else the tender offer is liable for rejection.
12.
(a) If so desired by JNKVV, the tenderer shall have to enter into an agreement.
(b) Any deviation, or non-compliance of the terms and conditions by the tenderer shall
be considered as a breach of contract and JNKVV reserve the right to forfeit the
amount of earnest money and or security deposit in part or in full and to take
actions as per legal arrangement.
13. Should there arise any dispute, the Vice-Chancellor, JNKVV, Jabalpur shall be the sole
Arbitrator, whose decision in the matter shall be final and binding.
J.N.Krishi Vishwa Vidyalaya reserve the right to accept or reject any or all offers in full or in
part without assigning any reason (s) therefore. It also reserves the right to place an order
wholly or in part with one or more than one firm as they may be convenient to JNKVV.
14. The tenderer shall have to give an undertaking that the terms and conditions as mentioned
above of this tender are acceptable to the tenderer.
Note: The details of tender documents can be obtained in website http:www.jnkvv.nic.in.
The tender document can also be downloaded from JNKVV website, which will be
acceptable only deposited along with IPO/DD ₹ 500/- (Non refundable) in favour of Dean,
College of Agricultural Engineering, JNKVV, Jabalpur payable at Jabalpur up to 05-01-2015
Dean
Agricultural Engineering
Department of Farm Machinery and Power Energy
RKVY Project
Specifications for different Items
1
Equipment
/ Approximate Specification
Instrument
required
Lathe Machine 1. Size of machine (Length) = 7 feet
Rs. EMD Rs
2. Width of bed, mm = 320-325mm
2000/
3. Height of center mm= 267 mm
4. Spindle bore mm 54 minimum
5. Swing over bed, mm – 450-480
6. Swing over slide max
7. Admit between center = 900-1000 minimum
8. Equipped with Electric motor 2hp (company name), cluck different size, switches
spanner, Elenkey set complete, clutch plate with appropriate cluck, center adopter, MT-3
/4,Dead center 2 No, 4 way tool post and key, change gear set for mm & Inch thread,
steady & follow rest, and other accessories.
2
3.
Spot welding
machine
Rs.500’
Shaping
Machine
Pedestal type spot welding machine, weldiability 34-14 SWG (0.23 to 2.003 mm) with all
accessories.
1)Shaping machine (All Geared Type)
Length of ram stroke: 660mm
Rs.3000/
Length of ram: 1225mm
Width of ram: 300mm
Max. Distance from table to ram: 450mm
Min. Distance from table to ram: 50mm
Vertical travel of tool slide: 140mm
Swiveling range to tool on either side: 60 degree
Table size: 610 X 380 mm
Horizontal travel of table : 600mm
Vertical Travel of table:350 mm
Nos. of speeds:4(With essential accessories)
4
Dynamometer
(25 kw ) for
testing engines
of self propelled
machines with
accessories
Computer based engine test rig for test of various engines used in self propelled
agricultural machinery
EMD Rs 10000/
Torque Measurement: With Load Cell, Output : 4 - 20 mA.
Engine : 4 stroke diesel engine of 25 kW capacity,
Dynamometer : The Engine is coupled with matching Eddy current dynamometer and
capable to couple with 4 stroke diesel engine, 2 stroke petrol engine
PƟ & PV Plot :
i) Piezo Sensor : 1 No. for combustion pressure.
ii) Spark Sensor : 1 No.
iii) Piezo Amplifier : 1 No.
iv) Crank angle sensor with TDC marker : 1 No.
v) Temp. Transmitter : 6 Nos. with Sensors.
vi) ADC Card : 1 No. with Complete Inter Facing.
Software: A Powerful software for studying different characteristics of I.C. engine (diesel and
petrol) e.g. Brake Power Vs Speed & Load, Heat Converted to Brake Power, heat goes to
exhaust gasses & heat unaccounted.
Computer: Intel core i5-2500 processor, 3.30 GHz, 6M cache, 4 cores/4 threads, Intel stable
image platform program (SIPP), Chipset : Intel Q65 OEM mothercards,1, Memory: 2 GB 1066
Mhz DDR3 RAM with 8 GB expandability, Hard disk drive: 320 GB or more 7200 RPM
Serial ATA HDD, Monitor: 18.5” wide TFT Digital color monitor, 104 Key boards, optical
mouse, Windows 7 Professional pre-loaded, Preloaded software : Norton or McAfee or e Trust
or e-scan or Quick Heal Antivirus (latest version), 3 years comprehensive H/W warranty, 6
USB ports etc. complete with HP Laserjet M1136 Printer
Fuel Measuring Device: Fuel flow Sensor for fuel metering.
Fuel tank mounted on sturdy iron stand, burette tube, three way cock, connecting
tube & a stop clock.
Calorimeter: Shell & Tube Heat Exchanger to measure the heat goes through
exhaust gases.
5
Engine/machine
eddy current
/electronic/hydra 1.
ulic/mechanical;
(8-10 kw ) for
testing engines
of self propelled
machines and
farm machineries
with accessories
Rs 10000/
2.
Air Intake Measurement: Air Intake reservoir of size 0.3 x 0.3 x 0.5 m. with orifice
plate,
U-Tube manometer of 0.5 m height.
With all set-up
Specification sheet for 8-10 HP dynamometer
Eddy current dynamometer (Water Cooled)
 Rated absorption Power = 6 KW / 8 HP or 13.4/10 HP
 Maximum torque = 70 Nm
 Maximum Torque at Speed = 1500 RPM
 Maximum speed = 12000 RPM
 Torque measurement precision = ± 0.25 FS%, 0.1 Nm resolution
 Speed measurement precision = ± 0.5 FS %, 1RPM resolution
 The direction of rotation both Clockwise & Anti Clockwise.
 Reaction type Torque Sensor to measure Torque, having 2 mV/V output.
 60 - Tooth wheel with magnetic pick up sensor to measure speed.
 Torque calibrating arms.
 Magnetic heavy duty water strainer filter.
 Water flow switch
 MS Shaft guard, Openable with hinges.
Dynamometer Controller
PC Based Dynamometer Data Acquisition & Control system, Floor standing
control panel PC Based Control Panel, consisting of:
 Dynamometer Control Circuit
 Constant Speed Mode – N.
 Constant Torque Mode – T.
 N / T Mode Selector switch.
 Interlock with Temp Sensor & Water Flow switch, Wiring, Terminals,
connector, Mains isolator.
 PC based set up, PCI Card with necessary Digital & Analogue inputs &
outputs, Engine TEST software developed using National Instruments
LAB VIEW, Facility to View / Print observation table and save the
acquired data of Torque (Nm) & Speed (RPM), Mechanical Power of
Engine, Temp Measurement Data in Tables & Graphs for Torque Speed, Power - Speed, Power - Torque, Temp – Torque or Custom
Curves, etc. in MS Excel format.
 Torque, Speed, HP/KW, All temperature parameters, would be displayed
on monitor & stored in tabular & graph formats in MS Excel.
 Auto / Manual selector switch. (Manual Mode is redundant to Auto
Mode. In case PC system for Auto mode fails, Dynamometer still can
be operated in Manual mode)
 Manual Dynamometer controller with following controls:
 Load Potentiometer: 10 turn helical with dial to control
Dynamometer in Manual Mode.
 Digital RPM Meter to read motor RPM, in Manual Mode.
 Digital Torque Meter calibrated to read Nm in Manual Mode.
 Digital Power Meter to read Engine Power in KW/ HP.
 SPAN, NULL & RESPONSE presets for Torque Indicator.
 PID Temperature Indicator Controller to indicate Engine Inlet & Outlet
water Temperature. Oil Temperature, Dynamometer Water Outlet Temp
(All 0 - 400ºC), Exhaust Gas Temp (0 - 1000ºC) – 5 Nos. Temp
Indicators with Temp Sensors with PT 100 Type sensors.
 Annunciators to indicate Faults – Dynamometer Water High Temp,
Engine Temp High, Oil High Temp, Low water flow.
 Tower Lamps for visual indication of System Start, Test Start &
Systems Stop.
1. Cable loom with conduit of 15 Mtr length: Cable loom consist Shielded
Control cables for Torque sensor, Speed sensor, Temp & Pressure sensors &
Dynamometer Control, with Male-female round type connectors with flexible
conduit of length of 15 Mtr.
4.
Engine starting system: The Engine starting system is mounted on non drive
end of Eddy Current Dynamometer. When operator presses Engine by START Push
button, on control panel, the starter motor gets engaged with starting wheel, which rotates
Engine to start. Once engine is started, START button should be released. Both Battery &
Cables for Engine starting is included in the scope of supply.
5.
Throttle Actuator: Normally engines are tested at different speeds. One end of
the throttle actuator cable is connected to engine throttle point and another end of throttle
cable is connected to throttle actuator. The throttle actuator is to be mounted near to
engine. From control panel the operator can vary engine speed by turning throttle demand
Potentiometer (i.e. 25%, 50% etc). Once Engine is started, the operator can increase or
decrease the engine speed by potentiometer in Manual Mode, Where as Engine speed
would be controlled thru
software when system is in Auto mode.
6.
Shut down actuator: The Engine would be turned off automatically by pressing
Engine OFF switch on control panel. Pneumatic supply line of constant 5 Bar, 75 PSI
pressure is to be connected to Engine shutdown actuator. When operator presses the shut
down switch from control panel, the cable connected to engine via shut down actuator is
pulled pneumatically from shut down actuator, which is mounted on stand near engine.
7.
T’ slot bed for engine mounting with mechanical jacks: Length & Width is
adjustable by T slotted fabricated bed & Height is adjusted by Mechanical jacks, with
anti vibration pads, Cardan shaft between Engine & Dynamometer with Shaft guard,
Engine mounting fixture, to mount Engine.
8.
6
Instran/ UTM
Rs.5000/
7.
Data logger
EmD: Rs 5000/
8
9
10
Plate form type
digital balance
EMD Rs. 500
Weighing
machine 1 kg
EMD Rs 1000/
Digital Load
cell with
indicator
EMD Rs. 2000
Gravimetric Fuel Consumption unit:
A Specially designed High Speed & high accuracy load cell signal conditioning
board directly provides digital readings for weight to the micro-controller. The
programmed micro-controller then takes care of operating the solenoid valves to
control the measurement processes.
 The Controller has facility of Digital Calibration by means of Key-pad and
Display.
 All the Functions during Measurement, Fill-up or in case of any failure are taken
care of by the Microcontroller of the instrument
 In-built Calibration facility.
 Maximum & minimum Fill-up level setting with weight of Fuel.
 High Accuracy Load Transmitter for sensing the weight.
 4 ½ digit display for Measured Quantity with a resolution of 0.1 for weight &
time and 1 for Revolution
 Digital Timer Display 4 digits for displaying the parameter being processed.
 Digital Display for selection of parameter.
 Digital display for showing current Flow rate. The Flow rate averaging time is
user settable. This display is continuously updated during measurement being
carried out. The Flow rate display has a Lease count of 1 gm/Sec
 Unique TARE & SET Calibration facility.
 3 modes of operation are provided viz. Time Base, Quantity Base & Revolution
Base.
 Overall Accuracy is within 0.3 % of selected Range. (1500 gm)
 Continuous measurement of average fuel consumption
 Capacity: 3 Kg/h.
Instran/UTM Microprocessor based universal testing machine 10 Tonn capacity with pc,
Printer and software. Complete with tension, compression & Transverse attachment
(With essential accessories)

Data logger having up to 8 to 15 output/inputs points/Channel. With the external storage
device up to 10 GB. The data logger should be included with the various sensor of
temperature having range 0 to more than 300OC, flow of water/liquid and air, humidity,
speed/rpm, pressure of liquids/water, wind speed and another sensor to monitor the
performance of biomass furnaces (0 to more than 15000C ) etc having high accuracy of
measurement/sensing. The proposed sensor of the data logger should be operate from
very small quantity of parameters to the large. The data logger should be easily interface
to the computer in online mode or data collected in off line mode.
Digital balance plate form type, capacity 200kg, least count
Least count 0.001 gram
125 kg, 500 kg, 1 -, 4 tonne with Beam and diaphragm combination. Tension,
compression and bi-directional options. Maximum error in axial force component
measurement is limited to 0.25% within a 3° angle swept through 360° around the load
cell axis. Its various end-fixing options are all inert and easily modified for direct
inclusion in mechanical assemblies. Integral
4 to 20mA or ±10V output amplifiers can be fitted as an option. Other specifications
Parameter Value Unit
Non-linearity - Terminal ±0.05 % RL
11
Sound level
meter
EMD: Rs.3000/
Hysteresis ±0.05 % RL
Creep - 20 minutes ±0.05 % AL
Repeatability ±0.02 % RL
Rated output - Rationalized 2.0 mV/V
Rationalization tolerance (applies to single direction calibrations) ±0.1 % RL
Output symmetry ±0.3 % AO
Zero load output ±4 % RL
Temperature effect on rated output per ºC ±0.002 % AL
with capable rod ends and suitable for indicator as specification below: power source 6V
sealed lead rechargeable battery bridged supply 5V dc fixed, calibration check internal
shunt resistor, accuracy ±0.02 %
Features:
Precision Type 2 instrument, Measurement range: 30 to 140 dBa, Response modes: Fast,
slow, Frequency weighting:, A, C, Displays SPL, Maximum SPL.
Includes: WS-7 wind screen, 56-990 calibrator Adopter, 56-533 storage case.(With
essential accessories)
12
Vibration
Meter
computerized
human/
machine
a) TECHNICAL SPECIFICATIONS:
(1)
S. NO
1
Mechanical vibration meter
4
Requirements
Mechanical vibration meter with triaxial magnetic base piezoelectric
accelerometer to measure
vibration in three mutually
perpendicular axis (X, Y and Z)
Measurement of Acceleration,
Velocity and Displacement
Suitable for measurement of vibrations
on Agricultural Machines
Measuring range:
5
6
7
8
Acceleration – 0.03 to /10 mm/sec2
Velocity – 0.03 to 10mm/sec
Displacement – 0.003 to / 10 mm
Frequency Range :
9
10
11
12
14
Acceleration – 0.3 to 15 kHz
Velocity – 0.3 to 15 kHz
Displacement – 3 Hz to 1 kHz
Display - 4 Digit, 7 Seg LCD at
least 10 mm character Height
Mode of Display - True RMS and
equivalent peak for displacement,
velocity and
Accuracy - ± 2 %
15
Power supply
16
Calibration – Self Calibration Check &
External Calibration clip
EMD:
Rs.10000/
2
3
13
b) Triaxial Charge Accelerometer
X
0.981
9.62
Y
1.007
Z
0.99
9
Axis
pC/m
s-2
Reference
Sensitivity
t 159.2 Hz
9.87
(w = 1000s’).
9.80 pC/g
RMS
AND 240C
Lower
Determined by the
frequency limit amplifier used
Upper frequency 12
12
12
kHz
limit (+ 10%)
Mounted
40
40
40
kHz
Reson
ance Frequency
Transverse
3.4
3.6
1.6
%
Sensitivity re
reference
Sensitivity
(at 30
Hz, 100 ms-2)
Transverse
14
14
14
kHz
Resonance
Frequency
Resonance
34.1
34.4 32.7
kHz
frequency
Quality factor 352
349 9
@ f rse
-2.1
-2.0 -2.1
%/de
Amplitude
c
slope
Measuring
± 10 kms-2 peak (± 1000
range :
a peak)
Max,
operational
stock
Max.
5 kms-2 peak (500 g
continuous
peak)
sinusoidal
Electrical
Capacitance of transducer (exc. Cable)
1000pF
Insulation Resistance sensing elements
> 20 Gohm
Mechanical
Case Material
Titanium ASTM
Grade 2
Sensing Element
Piezoelectric, Type
PZ 23
Construction
Sealing
Weight
Electrical connectors
Delta Shear
Sealed
55 gram
3 x 10 – 32 UNF
– 2A
Mounting Thread
10-32 UNF -2B
Mounting surface
< 3 um
Flatness
Mounting Torque
Max. 3.5 Nm
Accessories:- Accelerometer cable, double screened for extra EMC protection.
13.
Digital Cone
Penetrometer
EMD Rs. 2000
14
Harpenden
Anthrop meter
and skin fold
caliper
Technical Specifications for Digital Cone Penetrometer Meter with Data Logger
with GPS
Measuring Range: 0–18in (0–45 cm), 0–1,000 PSI (0–7,000 kPa)
Measurement Units: Cone Index (PSI or kPa)
Resolution: 1in (2.5 cm), 5 PSI (35 kPa)
Accuracy: ± 0.5in (1.25 cm) Depth, ±15 PSI (103 kPa) Pressure
Battery/Life: 4 AAA alkaline batteries; approximately 12-month life
Display (Build-in GPS): GPS measurement system
Numbers of Memory : 579 profiles with GPS
Built-in data logger and RS-232 port allows
Includes software and PC cable for data downloads
Carrying case
Direct and accurate reading to the nearest millimeter, range 50 to 570 mm, sliding
member operating via miniature ball- bearing, carrying case, complete with straight and
recurred branches, a spare counter and beam extension for the measuring of height up to
2 mtrs.
EMD
RS..1000/
15
16
17
Ergo kit
EMD Rs. 3000
Oxygen
Consumption
instruments
EMD Rs. 4000
Pollard system
for electro
cardiac
graphics and
stationery
Equipped with different accessories
range 0.1 10 lit/min Vo2 Batteries , portable
Multiple interfaces dual heart rate processing algorithms, 32 entry data history. (With
essential accessories) The dynamics and stationery system of heart rate measurement
equipment with computer analysis systems.
EMD Rs 5000/
18
Trade Mill
EMD Rs .2000/
0-12% elevation and 20 kmph speed and programmable. Technical data : motor-3 Hp
continuous duty, Running surface- 150 x 50 cm, Running belt – 2 ply, Speed- 1- 20 km/h
( adjustable in increments of 0.1 km/h), Inclination- 0-12 % ( adjusted in 1% increments),
Console :
19
Bicycle
meter
EMD
Display – time, distance, speed, inclination, pace, calories, pulse, display of course
profile with LCD, Training programs: 20, 4 direct selection buttons for speed. Features:
Heart rate measurement, chest strap incl., PC interfaces. Extras: transport wheel
ergo Manually programmable, inbuilt HR rate control programme, breaking power up to
600W, colour screen, inbuilt memory and performance test and computer and USB
interface, class I safety features with international standard, weight less than 50 kg and
carrying capacity 150 Kg
Rs1000/
20
Computerized
human energy
measurement
system with
telemetry
EMD: Rs.10000/
Flow meter
Flow range:
Ventilation Range:
Accuracy:
Resolution:
Gas Analyzer
Type
Range
Response time:
Accuracy:
Gas Sampling
Bi-directional digital turbine 28mm diameter
0-2
0-300
4
Oxygen
GFC
7-24% 02
<120 msec per 90% FS
0.02% 02
Carbon Dioxide
NDIR
0-8% CO2
<120 msec per 90% FS
0.01% CO2
Nafion
Breath by Breath
21
Fuel
consumption
measurement
Device With
indicator
EMD Rs 2000/
22
Carbon pollution
monitor
EMD: Rs.
4000/
Rotary Torque
Sensor with data
logger
23
Type:
Expired gas drying:
Heart Rate Monitor
Wireless double electrode (Polar)
Transmitter and receiver Unit
Memory:
16,000 breaths
Display:
LCD 2 lines x 16 characters
Keyboard, Serial port/USB
Thermometers:
Barometers:
Battery Type:
Battery Autonomy:
~ 6 hours minimum
Transmission distance:
Minimum l000 m
Note: The equipment should include the main unit with cables, 2 turbines, 3 face masks
(S, M, L adult), 3 rechargeable batteries, 2 sampling lines, Polar heart rate belt, 2 head
caps, user’s manual and adult harness Windows based system software c
Measurement range 5 to 1000 ml, digital display, suitable to fit to fuel supply tube.
Accuracy 1% it works for instant fuel consumption at any conditions.
Measurement of CO, Co2 No, So2 etc levels for Indoor air quality monitoring (With
essential accessories
With sensors 100 Nm, 500Nm, 1000Nm, 1500Nm, least count 0.02 to 0.2 Nm, Data
logger (with Strain soft software and PC based data logging in excel format) for 4
channels additional accessories like portable data logger 4 channel based battery
Nafion
RS
0-5
53-106
NI-
24
EMD: Rs.5000/
Torque pick up
with indicator
Rs.10000/
25
Non – contact
photo
tachometers
EMD : Rs 2000/
26
Test rig for
manually
operated
sprayers
EMD Rs. 1000
operated(With essential accessories)
Torque sensor:
Torque sensor with non contact type data transmission, digital torque data (USB) up to
1000 Nm, Keyway shaft, rotational / static measurement, Bi-directional measurement,
Battery operated, Calibration certificate, RS 232, Digital data, speed and power output
Torque Indicator:
Non Contact type digital indicator above torque sensor, operational temperature range 0
to 45 degree centigrade, battery life 12 hours, auto power off, RS 232 output,
Rechargeable battery with battery charger, complete with all accessories, including
mounting kit and carrying case. (With essential accessories)
Photo tachometers
Specification:
Range (rpm): 5 to 99,999, Accuracy: ± (0.05% rdg + 1d), Sampling Time: 1 sec> 60 rpm,
Resolution: 0.1 rpm (0.5 to 999.9 rpm); 1 rpm (>1000rpm),
Features:
Large 5 digit LCD display is easy to read Built-in memory recalls last MAX/MIN value
stored, Auto ranging with 0.05% accuracy, Non contact measurements from 5 to 99,999
rpm, User reflective marker on object to be measured and integral light beam or accurate
readings updated point every second, 2 to 6 inches (50 to 150 mm) measurement
distance (depending on ambient light)
Complete with 23” reflective tape, four AA batteries and case(With essential accessories)
This system is designed to conduct performance testing of manually operated sprayers as
per IS 10134-1994 facility of testing. Stirrup type sprayer. Foot and Rocker sprayer and
Knap sack sprayer. Auto miser sprayer .By changing the drive linkage mechanism is
provided alternately.
DESCRIPTION & SPECIFICATION.:1) Strong and sturdy fabricated frame structure made out of M.S channels and plates
to give sufficient rigidity to the machine.
2) Drive motor 2 H.P, 1440 RPM coupled with warm reduction gear box 20:1 ratio
to provide drive to the test sprayer.
3) Adjustable eccentric mechanism fitted on gear box out put shaft with max.
Stroke adjustment up to 150 mm.
4) Adjustable linkage with ball joints and guide bushes suitable for transferring
rotary motion motor to oscillating one of sprayer handle.
5) Discharge collecting pipe 6 mm ID and @ 800 mm length provided with
pressure gauge, pressure regulator and @ 2 m of flexible pipe for connecting to
pump discharge port and sump tank.
6) Digital flow rate timer to measure collective discharge of test sprayer for one
minute with return valve to sump tank.
Range: - 0 - 5 LPM.
7) Electrical panel comprises ofi)
A.C. variable speed drive for 5 H.P motor.
Other electrical accessories such as contactors, push buttons, MCB etc.
27
Test rig for This system is designed to conduct performance and endurance testing of hydraulic
power operated power sprayers as per IS 11313:2007 facility of testing.
sprayers
EMD Rs. 1000
DESCRIPTION & SPECIFICATION.:-
28
Spectrometer
EMD Rs. 10000
8) Strong and sturdy fabricated frame structure made out of M.S channels and plates
to give sufficient rigidity to the machine.
9) Drive motor 2 H.P, 1440 RPM coupled with warm reduction gear box 20:1 ratio
to provide drive to the test sprayer.3)The drive motor is mounted on swinging
filed dynamometer so that torque consumed is indicated on the panel suitable
flexible coupling attachment is provided for connecting this motor to test
pump.4) Discharge collecting pipe 10 mm ID and @ 800 mm length provided
with pressure gauge, pressure regulator and @ 2 m of flexible pipe for
connecting to pump discharge port and sump tank.5)Digital flow rate timer to
measure collective discharge of test sprayer for one minute with return valve to
sump tank. Range: - 0 - 10 LPM.6)Electrical panel comprises ofii)
A.C. variable speed drive for 5 H.P motor, Digital torque indicator.
Range: - 0 - 20 N-m., Digital Pressure
iii)
indicator.Range: - 0 -10 kg/cm2 I 3)Digital preset timer.Range: -0 - 99.9
hrs. ii)Other electrical accessories such as contactors, push buttons,
MCB etc.
Specifications
Spark System
o
o
o
o
29
30
31
Crane scale
EMD Rs 1000/
10 hp Dc motor
along with
control panel
EMD Rs 2000/
Multimedia
I-station
RS 2000/.
Easily accessible sample stand
Designed for easy cleaning
Argon Flushed
Tungsten electrode
 Software Operation
o User friendly menu driven software
o Factory calibrated
o User configurable alloy standardization
o Facility of delete bad RUNS
o Display of mean and SD/RSD
o Pot report generating facility
 Electrical Requirements
o 170 to 270 VAC, 50 Hz
o In built voltage stabilizer
 Control and Data Processing
o Contains built in Pentium PC
o Windows XP/7/8 (all versions) based Software
o Portable Pen Ram Drive
o USB Port
 Source
o Regulated excitation source
o Fully computer controlled
Unipolar discharge
Capacity: 3 ton, Accuracy 1 kg, (With essential accessories)
10 HP dc MOTOR WITH VARIAC , Volt , Ampare, RPM Regulators/control panel/1500 rpm/
220 volt/440 armature and switches etc.
Wireless microphone :
Frequency range : 740MHz ̴752 MHz , RF Output: 10 mW
Speaker : 2x 60 W speaker with woofers and tweeters, , Frequency range: 40 Hz ̴ 20
KHz, output 60 W RPM/ 160 W peak, weight 3.5 Kg.
Gooseneck microphone:
Frequency response : 150 Hz ̴ 17 KHz,
Software: Description: Electric lecturer stand/ electric board KPS S/W using for class and
presentation, Operation system: Microsoft windows 2000, windows XP, Windows XP,
Windows Vista, Windows 7/8; Hard disk: Over 160 GB.
33
Cutting force
measurement
device for field
crops
Disc: 40 cm, blade mounting device, blade set with varying angles, Control panel with
VFD for RPM optimization, motor 1 hp.
EMD. Rs 3000/
34
Operational
sound
reinforcement
solution
This is an attractive public address podium that features an all in one design. It has a
built-in 60 Amplifier, 60 W column speaker with one tweeter and three woofers. Flexible
gooseneck microphone and lamp are provided as well. Number of input and output
connections make it easy to expand its capacity. Available in white or black finish,
wooden top and steel bottom; goose neck MIC
.EMD Rs. 3000/
35
Cooling device
Rs.3000/
1.5 ton split type Air conditioner with fitting and stabilizers (including installation)
Power: 5-star rating
36
Tractor 35-40 hp
General specifications
EMD: Rs. 5000/
HP Category -35-40 HP
Type – 4 stroke, Direct injection, Diesel engine
No. of cylinders – 3
Bore and stroke – 100 x 116 mm
Displacement – 2734 cc
Rated Engine speed – 1800 rev/min
Air cleaner – 3-stage oil bath type
Cooling system – water cooled with no loss tank
Transmission
Clutch – standard, single dry disc friction plate – 280 mm dia. 11”
Optional
No of gears – 8 forward, 2 reverse speeds
PTO Speed- Standard-1000 rpm
Optional – 540 rpm
Tyres – Standard
Brake type - Standard - Dry Disc type Brakes
Optional - Oil Immersed Brakes
Steering type -Standard - Mechanical Steering with Heavy Duty single drop arm
for better maneuverability & comfort to operator
Hydraulics - Live Hydraulics
• Position control: To hold lower links at any desired height
• Automatic draft control: To maintain uniform draft
• Mix Control: For optimum field output
Lifting Capacity - Standard
3 point linkage Category-I suitable for Category-II type implement pins.
37
Notebook/
Laptop
EMD=1,000/-
Notebook
OS
Operating system
Windows 8.1 64 bit
PROCESSOR
Processor
Intel® Core™ i5-4210U with Intel HD Graphics 4400
(1.7 GHz, 3 MB cache, 2 cores)
MEMORY
Memory, standard
4 GB 1600 MHz, DDR3L SDRAM (1 x 4 GB)
STORAGE
Hard drive description 1 TB 5400, rpm SATA
GRAPHICS
Graphics
Intel HD Graphics 4400
DISPLAY
Display
13.3" diagonal HD anti-glare WLED-backlit (1366 x 768)
Display size
(diagonal)
13.3"
CONNECTIVITY
Wireless
802.11b/g/n (1x1) and Bluetooth® 4.0 combo
Expansion slots
1 multi-format SD media card reader
Network interface
Integrated 10/100 BASE-T Ethernet LAN
PORTS/SLOTS
Ports
2 USB 3.0; 1 USB 2.0; 1 HDMI; 1 RJ-45; 1
headphone/microphone combo
INPUT
Webcam
TrueVision HD Webcam (front-facing) with integrated
dual array digital microphone
Keyboard
Full-size island-style keyboard
Pointing device
Imagepad with multi-touch gesture support
AUDIO
Audio features
BeatsAudio™ with 2 speakers
POWER
Power supply type
65 W EM AC power adapter
Battery type
3-cell, 43.5 Wh Li-ion
SECURITY
Security management Kensington MicroSaver lock slot; Power-on password;
Accepts third-party security lock devices
WARRANTY
Warranty
1-year on-site
Terms and Condition:
Taxes
Transportation
Other charges SUCH AS OCTROI,
INSURANCES, INSTALLATION,
MOUNTING , WIRING, COMMISSIONING
ETC WILL BE DONE BY THE SUPPLIER
TIN /PAN NO.
Validity
Delivery
Warranty
Mode of Payment
FOR
Please give the following details
After delivery and successful installation
JABALPUR, M.P.
Details of Registration of the firm
Details of location of the firm & its service centres
Enclosure No.
Enclosure NO.
Details of after sales service where ever applicable
Enclosure NO.
Documentary evidence of being an authorized
representative/supplier and dealer
Catalogues showing the technological core
competence
Details of EMD
Details of some esteemed customers and their
testimonials
Any other document as may be necessary as per
tender
Enclosure NO.
Enclosure NO.
Enclosure NO.
Enclosure NO.
Enclosure NO.
Download