Samsung Mini Splits Application New Products 2009 Why Buy a Mini Split? • Zoning • Comfort • Energy Efficiency • Simplicity • Noise • Space Saving Basic Mini Split Applications Computer or Data Rooms Commercial Spaces Residential All 3 have different rules of thumb when it comes to sizing and also the accessories needed for proper operation, but the general rule of SIZE THE UNIT TO THE ROOM must be used. For specific applications always use a Manual J Computer/Data Rooms • Basic Rule of thumb Sizing : 200 to 250 sqft per 12,000 Btu/h • Remember the unit is in 24/7 operation 365 Days a year • Must ensure that the room layout does not have any server banks or other equipment within 12 to 15ft of the front of the unit 09/12k and 20 to 25ft for 18/24k Commercial Installations • Warehouse office or break rooms • Multiple use offices • Training Rooms • Conference Rooms • Bars • Restaurants • Nursing/Extended Care facilities • Churches • Hotels • Schools Residential Installations • Basic Rule of Thumb Sizing : 500 to 600 sqft per 12,000 Btu/h • • • • • • • Hydronic Heated Houses Garages Bonus rooms or FROG’s Media/Game Rooms Home Offices Home Gyms Sun Rooms/4 Season Rooms • Household Hot Spots • Basements And the Old Chestnut • Replacing Window units • Mitsubishi are going extremely hard after this market segment • Advantages - Noise, efficiency, security, ease of use, aesthetics • • Guess the number of Window units sold in North America???????? Samsung Mini Splits 2009 Product Line Up “Comfort through Innovation” High Wall AQV Series AQV09, 12, 18, 24, 36 High Wall Vivace Model AQV12V, 18V, 24V EH Slim Ducted Models EH035, 052, 070 DH Medium Static Pressure Ducted DH105, 140 Free Joint Multi High Wall / Ducted Multi System Outdoor – MH050, MH080 Indoor High Wall – MH026, 035, 052 Indoor Slim Duct – MH0236, 035, 052 4 Way Ceiling Cassette CH070, CH105, CH140 Floor Standing APV48 AQV Product 9-24k in detail Attractively styled AQV Indoor Unit Slim line Outdoor Unit AQV36 in detail Samsung Smart Inverter Three Key Components • Samsung Manufactures Compressors in Capacities up to 60,000 Btu/h • Indoor Unit Controller • Outdoor Unit Controller What’s a Samsung Smart Inverter System? Variable Capacity Comfort Based on the Synchronous Operation of the Three Components Indoor unit measures room temperature; receives the desired conditions from the end user via the remote; calculates the difference between room temp and the set point; Communicates this to the outdoor unit; controller measures outdoor ambient and selects compressor and fan speed to provide exactly the comfort required Why use the Samsung Smart Inverter? Energy Savings • Looking at the annual usage compared to a standard 13 SEER/7.7 HSPF unit • AQV09JA Cooling Cost $38 • Heating Cost $137 Total $175 • QSHE-091 Cooling Cost $60 Heating Cost $179 Total $239 Why use the Samsung Smart Inverter? • Starting Current • How many buildings do you see the lights flicker when the compressor starts? • The Smart Inverter eliminates this issue completely by soft starting • Start up current on an AQV09 is <1 Amp, compare that to the QSCE at 35 Amps Summing Up Smart Inverter • Benefits of the Smart Inverter • Rapid cool down/heat up to set temperature • Much tighter room control to set temperature • Wider operating range in capacity and temperature • Lower Noise Levels Indoor unit Features • Silver Nano Air Filtration • All surfaces in the Indoor unit are coated with a silver based anti bacterial coating How Silver Nano health system works? Silver Nano 0.1nm 1 10 Virus An atom/ molecule 100 1,000 Giga Visible D-RAM ray 10,000 A red blood corpuscle 100,000nm A human hair Nano-Technology Mechanism Sterilization Efficiency • Bacteria: 99.9% Removed Bacteria Cell Cell Wall dissolved Cell Membrane burst Bacteria dies • Fungi: 99.9% Removed Indoor unit Features • Waterfall Airflow Direction & Double Blade Vanes • Allows the heating air flow from the unit to be directed straight down to promote faster heating of the room • Double vanes ensure maximum air throw AQV Airflow Cooling AQV Airflow Heating Indoor Unit Noise Levels 12,000 & 24,000 Btu/h Evaporator • 12,000 Btu/h • High Speed • Low Speed 43Db 25Db • 24,000 Btu/h • High Speed • Low Speed 48Db 33Db Outdoor unit Noise Levels Noise Outside Counts Too • 12,000 Btu/h • • Rated performance 45Db • This will reduce as the unit modulates in capacity Vivace AQV12V, 18V, 24V Vivace Indoor Unit Features • Silver Nano Air Filtration • All surfaces in the Indoor unit are coated with a silver based anti bacterial coating I. Why MPi? ■ Airborne infections become a hot issue 27 I. Why MPi? ■ MPi makes the Indoor Air healthier Samsung Electronics announces a world- first, a technological breakthrough in air purification. H+ H+ H+ H+ H+ O2- e e H e e e H+ H H O2 - H H O2O2- The MPi Technology is the world’s first use of a Hydrogen Atom and Oxygen Ion to start the the novel chemical process that purifies indoor air. H O2- By using a Hydrogen Atom and Oxygen Ion, which are harmless to the human body, we are able to neutralize most airborne particles, including viruses, bacteria, fungi and even allergens. 28 II. MPi Zone operation ■ Working mechanism Electrode Plate (+) : Micro plasma discharge splits water molecules in the air and forms positively charged hydrogen atoms. Airflow 29 II. MPi Zone operation ■ Working mechanism Electrode Pin (-) : High voltage electric discharge emits electrons and forms H atoms plus negatively charged oxygen ions. Airflow 30 II. MPi Zone operation ■ Chemistry H atoms and negatively charged oxygen ions are combined to form Peroxide O2- H O2H 31 II. MPi Zone operation ■ Cleaning mechanism Seeking out of Airborne Particles - The Hydrogen atom and negative oxygen ions are drawn to airborne particles due to their positive electrical charge. HOO- HOO- HOOHOO- + + + + + + HOO- + + HOO- + + + HOO- + + + + HOO- HOO32 II. MPi Zone operation ■ Cleaning mechanism Peroxide ion eliminates three hydrogen atoms from the virus HOO HOO HOO C H HOO HOO O 3H + HOO C H HOO HOO O C HOO HOO H O 33 II. MPi Zone operation ■ Cleaning mechanism After the peroxide ion eliminates the three hydrogen atoms from the virus, water molecules are formed and the airborne virus becomes inactive H2O H2O H2O H2O H2O H2O H2O H2O H2O H2O 34 II. MPi Zone operation ■ Virtually zero Ozone emissions MPi is free from the issues and odor associated with O3 SAMSUNG regulates ozone production to stricter level than world indoor air quality restrictions World O3 Restrictions 50ppb Limitation 20ppb Odor recognition 10ppb SAMSUNG JEMA (Japan) EPA (USA) HC (Canada) IEC (EU) CA (Korea) MPi Zone 35 Vivace - Air Quality Features • This filter will block up to 85% of allergens from being recirculated back into the room during system operation • Evaporator is treated with Samsung’s Sliver Nano coating • Washable and Carbon Filters are also included Vivace Unit Features • Slim Line, only 7 ½” deep • Front panel automatically opens from the top when unit is running • Shadow Mirror effect appears like black Carbon Fiber Vivace Unit Features • Embedded temperature and operation display • Display can be either turned On or Off via the remote control • Display is in Fahrenheit • If required in Celsius, the PCB and Display have to be replaced Vivace – Added Control Features Vivace – Added Control Features • Auto Clean mode • Acts after the cooling or heating mode has completed and prior to unit shutdown • Will dry all the condensation off the Indoor coil and prevent any odors occurring when the unit is re-started Indoor unit Features • Silent mode – this allows the unit to operate with the quietest possible noise levels, making the unit perfect for bedroom applications – Available in Heating and Cooling operation What Is Noise? EH Slim Duct EH Indoor Unit Outdoor Unit, including a plastic, corrosion free fan guard EH Unit Features • Minimal drop ceiling height required, less than 10” above the ceiling, 8” is the minimum • Unit height is 7 7/8” • Units are designed to be smaller than a single ceiling tile – EH 052 & 070 are 43 3/8” wide and 23 5/8” allows simple installation and product access EH Unit Features • Up to 10% Fresh Air can be introduced to unit for commercial applications • Approximately 65 CFM • Ensure Fresh Air inlet does not affect the return air temperature sensor to give a false reading and cause over heating or over cooling of the room EH Unit Features • Up to 0.16” WC external static pressure available • Return air can be free or ducted, multiple filter locations available either at the unit or in the return air grille/ductwork – Filtration not included with the unit • Recommended application with free return air • Approximately 40-60ft total ductwork with 4 to 6 registers EH Standard Controller • MWR-TH01 Wired Remote Controller is provided with the unit – DegF or DegC display • Does not sense temperature so it can be remotely mounted for security • Temperature is sensed in the return air stream (Sensor is located on blower wheel inlet) EH Controls – Dip Switches • Dip Switch #4 • Condensate Pump output for optional internal Samsung condensate pump • Requires removal of drain pan for fittment • Condensate Pump has a 30” head, and inbuilt overflow protection EH Control Features • Dip Switch #7 • Hot Water Coil - Output for a Hot Water coil, which is mounted on the supply air side of the unit – Coil is field sourced • 230V AC to drive a relay to energize a boiler or hot water valve • Does require the unit to be recoded as a Cooling only unit – cannot offer Hot Water Heat in conjunction with Heat Pump heating EH Control Features • Dip Switch #11 • Remote Start/Stop – Dry Contact for starting and stopping the unit • Can be wired into a smoke alarm, BMS system or other requirement for unit control • Unit will recall the previous set point and system operation DH Medium Static Product DH Indoor Unit Outdoor Unit, Slim line in design and simple to install DH Unit Features • Minimal drop ceiling height required for the capacity of product • Less than 18” above the ceiling, 16” is the minimum DH Unit Features • Up to 10% Fresh Air can be introduced to unit for commercial applications up to 135 CFM • Ensure Fresh Air inlet does not affect the return air temperature sensor to give a false reading and cause over heating or over cooling of the room DH Unit Features • Up to 0.5” WC external static pressure available • Return air can be free or ducted, multiple filter locations available either at the unit or in the return air grille/ductwork • Filtration not included with the unit DH Unit Controller • MWR-S00 Wired Remote Controller supplied as standard with the DH systems • Cannot be used on the Slim Duct unit • Same Control as DVM Plus III, with similar features available • Display can be shown in DegF or DegC however… DH Unit Controller • Allows for 7 Day scheduling for the system, including an occupied/unoccupied mode • Clock is real time but is in the 24hr not AM/PM • Multiple schedule settings can be inputted into the controller • Error codes and unit service data can also be accessed on the controller MWR-WS00 • Buttons control unit functions • Quiet mode reduces fan speed and noise level • Temp shows actual room temperature when pushed • Temperature limits can be programmed to prevent user changes above a certain point DH Group Control • Multiple Indoor/Outdoor units can be controlled by a single MWR-WS00 or we can do Master and Slave with controllers • Wire MWR-WS00 to master unit, then daisy chain wiring to the F3-F4 wires on all other Indoor units to be controlled by the MWR • No address setting required as MWR is in direct contact with the slave Indoor units DH Control Features • Dip Switch #7 • Hot Water Coil - Output for a Hot Water coil, which is mounted on the supply air side of the unit – Coil is field sourced • 230V AC to drive a relay to energize a boiler or hot water valve • Does require the unit to be recoded as a Cooling only unit – cannot offer Hot Water Heat in conjunction with Heat Pump heating DH Control Features • Dip Switch #11 • Remote Start/Stop – Dry Contact for starting and stopping the unit • Can be wired into a smoke alarm, BMS system or other requirement for unit control • Fresh Air fan output whenever Indoor unit is operating • 230V 1A signal to drive ERV/HRV/Damper etc Free Joint Multi units MH050 Outdoor Unit Note the Dual line set connections MH080 Outdoor Unit, Single service valves with manifold connections FJM Indoor units Neo Forte Indoor Unit Slim Ducted Indoor unit Not the same unit as the single zone EH units FJM Indoor Units – Neo Forte • Available in nominal 9,000 – 12,000 - 18,000 Btu/h capacities • 9k and 12k units are in a single chassis size • Wireless remote control as standard • Wired remote control optional • Ultra low noise levels as low as 23 Db • New design Indoor unit, aesthetically pleasing FJM Indoor Units – Slim Duct • Available in nominal 9,000 – 12,000 - 18,000 Btu/h capacities • Less than 10” Ceiling drop height required • Wired remote control as standard • Wireless remote control optional • Ultra low noise levels • Up to 10% Fresh Air can be introduced 050 Outdoor system combinations Outdoor Models Up to 24,000 Btu/h capacity Indoor Models 9,000 Btu/h 12,000 Btu/h 18,000 Btu/h Wall Mount MH026FNCA MH035FNCA MH052FNCA Combinations - Dual Zone Capacity Outdoor Unit 2 x 9,000 MH050FXCA2A 9,000 + 12,000 MH050FXCA2A 2 x 12,000 MH050FXCA2A MH050FXCA2A Slim Duct MH026FECA MH035FECA MH052FECA Indoor Units MH026 + MH026 MH026 + MH035 MH035 + MH035 Neo Forte Indoor and Slim Duct can be mixed matched to suit applications 080 Outdoor system combinations Outdoor Model Up to 36,000 Btu/h capacity Indoor Models 9,000 Btu/h 12,000 Btu/h 18,000 Btu/h Wall Mount MH026FNCA MH035FNCA MH052FNCA Combinations - Dual Zone Capacity Outdoor Unit 9,000 + 18,000 MH080FXCA4A 12,000 + 18,000 MH080FXCA4A 18,000 + 18,000 MH080FXCA4A Combinations - Tri Zone Capacity Outdoor Unit 3 x 9,000 MH080FXCA4A 2 x 9,000 + 12,000 MH080FXCA4A 2 x 9,000 + 18,000 MH080FXCA4A 3 x 12,000 MH080FXCA4A 2 x 12,000 + 9,000 MH080FXCA4A Combinations - Quad Zone Capacity Outdoor Unit 4 x 9,000 MH080FXCA4A MH080FXCA4A Slim Duct MH026FECA MH035FECA MH052FECA Indoor Units MH026 + MH052 MH035 + MH052 MH052 + MH052 MH026 MH026 MH026 MH035 MH035 Indoor Units + MH026 + MH026 + MH026 + MH035 + MH026 + MH052 + MH035 + MH035 + MH035 + MH026 Indoor Units MH026 + MH026 + MH026 + MH026 Neo Forte Indoor and Slim Duct can be mixed matched to suit applications Controls – Slim Duct • MWR-WS00 Wired Remote Controller is provided with the Slim Ducted • Can either sense temperature or use the return air temperature sensor in the unit – this allows locating either in the room or remotely mounted for security • 7 Day Scheduling feature • Wireless remote control provided with the Neo Forte unit Controls – Neo Forte • Wireless remote control provided with the Neo Forte unit • Wired control – MWRWS00 can also be used as an optional control for applications where a wall mounted controller is needed (Hotels or Apartments) • Units need to be in the manual address mode Controls – FJM • It is possible to have all or some of the Indoor units controlled in a group type situation • If the MIM-B13 Interface Module is attached to the Outdoor unit(s) – Units installed on different Outdoor units can be controlled by the same remote • MWR-WS00 Control Solutions Control solution Samsung Digital Solution raises the standard of your building management to a premium level. Building Centralized controller DMS Function controller Wireless Remote con Wired Remote con S-Net II,III Mini Power Distribution Unit 7 - Day Scheduler Lonworks Management 4 Way Cassette CH Indoor unit 4 Way Discharge Fascia CH unit Design ■ Design concept and Features Stylish Design Aerodynamically designed Turbo Fan Fan speed controlled with BLDC motor Air flow range increased Uniformly distribution of 4-way air flow Quiet operation Easier to maintain Anti–smudging: Blade shape and control Easy height adjustment CH unit Design ■ Uniform Distributed 4way Airflow for CH140CAV Confirmed by Experimental Test and CAE Analysis. Fan revolution Evap. : condition (Fin and tube) Shown Standard Deviation of distribution lower than old model. ■ Old Model ■ New Model Calculated Flow Rate, CMM 16.0 37%▲ Filter : specification blade angle 12.0 Pump 8.0 σ (STD Deviation) 2.4 → 0.6 4.0 0.0 ④ ③ : 75% Improvement ① ② ③ ④ Pipe ① ② CH unit Design ■ Newly Shaped Blade Air velocity is now more uniform Air flow increased at blade edge. Designed degree Blade designed to prevent dirt attaching to the ceiling Old model’s Smudging (dirt cling) Air velocity measurement Ceiling B A Dirt cling location C -20 -40 -60 -80 -100 -120 -140 -160 ■ Air velocity Center: high, Edge: low → Turbulence at ed → Stagnation → Dirt cling Old model 100 New model 100mm Outside 250 200 150 100 0 -50 -150 -155 -200 -125 -100 -95 Height [mm] 50 -65 300 0 -35 0 Velocity [m/s] 5 -250 250 200 150 100 50 -50 -100 -200 -155 -250 -125 -150 -65 -95 -300 Height [mm] 0 -35 300 5 -300 Profile of air velocity at location C Velocity [m/s] 100mm Outside CH unit Design ■ Air Flow distribution Increase flow without increasing velocity [COOLING MODE] 30 min after starting New model Company A Discharged air reaches farther than before. Choice option depending on the ceiling height [HEATING MODE] 30 min after starting New model Company A CH unit Design ■ Easy height adjustment Each corner of the unit has an adjuster pocket Allows installer to easily adjust the unit’s suspended height. 4 Way Cassette • Fresh Air Capability • Units are capable of handling up to 5% of airflow as fresh air • A 230V Output is available to drive a ventilation fan on the fresh air ducting – Maximum 1A 4 Way Cassette • Additional Features • Sub Duct • This allows the unit to force air into a duct which can be used to condition an adjacent space • Use either 6” or 8” ducting for max airflow 4 Way Cassette • Additional Features • Condensate Pump – 30” lift • Energized when the compressor is operating • Overflow safety switch will cut off cooling operation if pump fails or condensate drain is blocked CH Unit Controller • MWR-S00 Wired Remote Controller supplied as standard with the CH systems • Same Control as DH unit h similar features available • Display can be shown in DegF or DegC however… Floor Standing APV unit Indoor Unit Outdoor Unit, Slim line in design and simple to install APV Product features • Single model in range • Nominal 48,000 Btu/h capacity, BUT Inverter compressor capable of reducing capacity down to below 12,000 Btu/h • Single Phase Power • Up to 246ft line set length • Simple to install Accessories • Line Sets 25ft and 50ft lengths, both lines are insulated and include 14-3 and 16-2 Shielded Interconnecting wire • New and improved pricing on line sets Accessories • Condensate Pumps for unit installations on interior walls – Pumps are available in several styles with and without covers • Condensate Pumps for Ducted units – Samsung OEM Accessories • Condenser Brackets • Capable of holding all of the Outdoor units • Trellis design with built in level • Condensate scavenger • Uses positive pressure to assist in draining condensate from all High Wall units Support Available Sales Support Local Representation Quietside sales staff Golden, Lee Regionalized Customer Support Technical Support East Coast 717 243 2535 Denis, Mike, Chris, Colby, Bobbi West Coast 562 699 6066 John, Stu, Kevin Website : www.Quietside.com Samsung Warranty • 5 Years Compressor • 3 Years All other parts • 120 Days limited labor • All warranties commence on the date of installation • Warranties processed in our East Coast office, parts can be shipped directly to the installing contractor if required Website A new & improved site launching 2nd quarter 2009 • • • • • Product information Distributor spotlight Contractor data Training videos Case studies and more Thanks for listening Any Questions?