Compressor - CFAS Enterprises Inc.

advertisement
CFAS Enterprises Inc.
After Market Utility Power Equipment Brokerage
Mailto:Staff@CFASPower.com
Turbine URL: http://CFASPower.com/index.html
Reciprocating URL: http://CFASPower.com/Recips.html
GTG-165HT-RR/SK30doc
Rolls Royce Olympus SK 30 (Upgraded SK20)
Industrial Gas Turbine Generator Package Gas



One (1) Rolls Royce Olympus Sk30 C
Range Rated 24mw
50hz




Can Be Converted To 60hz
Dismantled In Canada - Stored Near Calgary,
Power Turbine Partially Refurbished
Asking Price $850,000
This Package Is A Sk20 Upgrade To Sk30 And The Condition Is Basically As Follows:
The Engine Has Been Serviced And Updated In A Specialist UK Shop, It Is Now
Complete And Ready For Use. We Can Deliver It Anywhere As It Has A Flight Canister.
The Engine Can Be Inspected In Aberdeen, Scotland, Uk, It Is In Storage At The Repair
Facility. Full Report On The Engine Available If Required, It Is A Low Hour Unit In Very
Good Condition.
Updates Were Done To The Bearing Oil Feeds Which Was A Rolls Royce Modification.
The Power Turbine, Housings Etc Are At Our Project Site In Fort
Macleod, Alberta, Canada. These Are Stored In An Aircraft Hangar And Protected From
The Weather. The Unit Was Fully Operational When It Was Dismantled. I Would Say
That It Will Benefit From Cleaning And Painting.
The Actual Generator Is Still In Perth, Australia Where We Purchased It. It Is A 50hz
Unit Which Was Not Suitable For Our Purposes So We Did Not Transport It. It Is
Properly Stored And In Good Condition, Complete With Switchgear. Transport And
Reassemble The Unit Available.
The Entire Unit Is In A Sound Attenuated Outdoor Enclosure.
The Unit Is Enclosed In An Acoustic And Weatherproof Canopy For Quite Operation.
The Units Skid Mounted So Civil Works Will Be Minimal.
The Engine Gas H.P. Is Transmitted Through A Two Stage Power Turbine, Coupled To
A Oil Pump Gearbox And Then Through A SSS Clutch To A 11KV Brush Alternator.
There Is A Separate Container Housing The Digitally Controlled Engine, Generator,
MCC And Circuit Braker. There Is Also Another Container Housing Lubrication And Fuel
Pumps. The DC Starting Batteries Are Enclosed In A Completely Mobil Box. There Are
80 Dry Element Filters Housed In The Air Filter Housing. The Unit Can Be Fired On
Either Gas Or Diesel. The Machine Can Be Operated At 50 HX.
Design Features
Compressor
Type:
No. LP stages:
No. HP Stages:
“B” Pressure Ration:
“C” Pressure Ration:
Airflow:
Design Speed:
Max. Speed:
Axial, twin spool
5
7
10.4 to 1
11 to 1
235 lbs per sec.
5,680 RPM
8,750 RPM
Combustor
Type:
Ignition:
No. Igniters:
No. Fuel nozzles:
Can-annular
Electrical High Energy
2
8
Compressor Turbine
Type:
No LP Stages:
No. HO Stages:
Cooling:
HP Blades:
Reaction/Impulse
1
1
HP Vanes (“B” & “C”)
(“C” Only)
Bearings
Journal:
Thrust:
Roller and Ball
Ball
Starter
Basic;
Optional:
Air Expansion
Gas Expansion
Control System
Basic:
Pneumatic/Hydro-mechanical
Materials of Construction
Compressor
LP Casing:
HP Casing:
“B” Vanes:
“B” Blades:
“C” Vanes:
“C” Blades:
Disco:
Combustor
Outer Casing:
Flame Tube:
Head Nimonic 75
Aluminum Alloy
HV448
FB448
Titanium
FV458
Titanium
FV448
FV448
CrCoMoNI Steel (C263)
Compressor Turbine
“B” HP and LP Disco:
“C” HP Disc:
“C” LP Disc:
“B” Vanes:
“B” Blades:
“C” Vanes;
“C” HP Blades:
“C” LP Blades:
“B” casing:
“C” Casing:
Exhaust
“B” Annulus:
“c” Annulus;
FV448
FV535
FV448
X40
Inco 738
Inco 738
Inco 792
FV507
Nimonic 80A
Nimonic 90
C263
Key Dates
Development Date:
First prototype Built:
First production Unit Operating:
First marine Installation;
1980
1961
1962
1967
Basic Performance ISO Conditions. No Inlet/Exhaust Losses
Output:
28,100 kW
Heat Rate:
Mass Flow:
GG Exhaust temperatures:
Baseload
Distillate
Peak Load
Distillate
37,800 hp
28,900 kW
11.150 Btu/kWh
238 lbs./sec
1455 F
38,780 hp
11,120 Btu/kWh
240 LB/sec
W Assume 85% efficient Power Rating
1. Olympus Mk2017-020 Marine One- S/N 64/c20
2. Various Pasts are listed in Catalog and all parts and service manuals located in 40 ft
container.
3. Various lifting services
4. Complete Engine stand.
5. 1-Spare cooling fan
6. Oil cooler S/N 1-2 28-11-15 Thermo engineers complete.
7. 1-circuit breaker
8. 2-Duct extraction fans.
9. 4-Walkways and stands.
10. 1-Oil pump room and fuel farm containing SC & DC pump and tanks.
11. 1-Air filter housing.
12. 1-Premium chamber.
13. 1-Cover for extraction
14. 1-Bell mouth.
15. 1-Exhaust Stack (2 pieces).
16. 1-Enclosed generator compartment containing (1) Brush generator 584911 S/N
25850 KVA 1000 Volt.
17. 1- Enclosed power turbine housing with frame and mounts for Olympus.
18. All generator, engine, fault relay panel, battery charger. All housed in 40 foot
container.
Performance Test Heat Rates




Ambient Temperature:
Ambient Temperature:
Calorific value fuel;
S.G. of fuel at 30 C:
1. Load:
Fuel Flow:
Gal/Kw
2 Load:
Fuel Flow:
Gal/Kw
1.05 lbs/Kw
20 C
974cmillibars
18350 BTU/lb (net)
8415
2.025Mw
0.134 cu. Metras/4 mins.
448.8 gal/hr
0.222 gals/Kw
1.87 lbs/Kw
343145 BTU/Kw
36373.370 KJ/Kw
5.046 Mw
0.193 cu. Metras/4 mins.
663.6 gal/hr
0.126 gals/Kw
19267.50 BTU/Kw
20423.55 KJ/Kw
3. Load:
Fuel Flow:
Gal/Kw:
4. Load:
Fuel Flow:
Gal/Kw
UNIT
8.0125 Mw
0.249 cu. Metras/4 mins
818.4 gal/hr
.012 gals/Kw
.858 lbs/Kw
15744.3 BTU/Kw
16688.95 KJ/Kw
10.07Mw
0.289 cu. Metras/4 mins.
950.400 gal/hr
.094 gals/Kw
.791 lbs/Kw
14515.03 BTU/Kw
14514.03 KJ/Kw
15385.931 KJ/Kw
.
TABLE OF ESTIMATED DIMENSONS AND WEIGHTS
LENGTH
WIDTH
HEIGHT
ESTIMATED
WEIGHTS
1-AIR INTAKE
Lower Half Intake Unit
138 in. (3.505
126 in
m)
(3.200m)
Upper Half Intake Unit
306 in. (7.772
330 in
m)
(8.382m)
2-GAS GENERATOR AND POWER TURBINE
Gas Generator
142 in. (3.607 m) 42 in (1.066m)
Enclosure- Dry
333 in. (8.458 m) 126 in (3.553)
Weight, Enclosure,
Skid And Power
Turbine
3-A.C. GENERATOR
Generator &
Enclosure
404 in. (10.26 m)
4-ACCESSORIES PACKAGE
Package
132 in. (3.352 m)
207 in (5.258m)
14,947 lbs (10,000kg)
171 in (4.343m)
18,988 lbs (15,000kg)
4,800lbs (2177kg)
152 in
(3.3861m)
129 in. (3.28 m)
171 in (4.343m)
76,100lbs (40,000kg)
120 in. (3.048
m)
120 in. (3.048
m)
172,240 lbs (85,000kg)
5-EXHAUST PACKAGE
Diffuser Duct
51 in. (1.295 m)
Support Duct
Silencer Duct
102 in. (2.501
m)
117 in. (2.972 m)
126 in. (3.220
m)
210.5 in. (3.05 m) diameter
6-OIL AND AIR RADIATOR PACKAGE
Package
206 in. (5.276 m)
100 in. (2.513
m)
7-COMPRESSOR WAS/INIBIT PACKAGE
Package
46 in. (1.168 m)
48 in. (1.219 m)
.
6.720lbs (7,000kg)
253 in. (6.348
m)
196 in. (5.029
m)
2,280lbs (7,000kg)
118 in. (2.990
m)
7.826 lbs (3,500kg)
54 in. (1.372 m)
743 lbs (337kg)
6,160lbs (5,000kg)
Download