Product Part Number Guide

advertisement
Product Part Number Guide
September 2009 [Interim copy]
Product Part Number Guide
How to print single pages
1.
2.
Place your mouse cursor on the page you want to print out.
From the menu File, select Print. In the Print dialog box under Page range, select Current page. Click OK.
(do not use the Print icon on the toolbar, otherwise all the pages in the entire document will be printed)
How to determine your meter part number
1.
2.
3.
Select one Order Code from each of the ordering categories.
Combine these order codes to form the part number for your particular meter configuration.
Use that part number when you fill out your purchase order.
Brand
Example part number
Model
S
7
Form
Factor
6
5
0
Current Voltage
inputs inputs
A
0
C
0
Power
supply
B
6
System
Freq
A
0
Comm
A
0
I/O
Security Special
Order
A
In the above example, the part number P7650A0C0B6E0A0A corresponds to:
Brand:
Model:
S
7650
Form Factor:
A0
Current Inputs:
Voltage Inputs:
Power Supply:
System Frequency:
Communications:
Onboard I/O:
Security:
Special Order:
C
0
B
6
A0
A
0
A
Rev date: January 2009
Square D brand
ION7650 power meter
Integrated display with front optical port, 5 MB logging memory,
and 512 samples/cycle resolution.
5A nominal, 20A full scale current inputs
57 to 347 VAC line-to-neutral / 100 to 600 VAC line-to-line
85-240 VAC, ±10%/47-63 Hz/110-300 VDC, ±10%
Calibrated for 60 Hz systems
1 RS-232/RS-485 port, 1 RS-485 port, infrared optical port.
8 digital inputs, 3 Form C relays, 4 Form A solid-state outputs
Password protected, no hardware lock
None
Page 3 of 23
70052-0188-43
Product Part Number Guide
Revision History
Rev
20
Date
Description of change
September 7, 2005
Added PQDIF Exporter add-on part numbers to ION Enterprise 5.5 section.
Added RS-485/Modbus communications option to ION6300. Modified ION Wireless Repeater part number and
ION6100 & ION6300 options code scheme (combined last three option code characters into one field).
Replaced ION8300/8400/8500 technical documentation/user guide part numbers with ION8600 part numbers.
21
September 19, 2005
Part number corrections for accessories.
22
October 12, 2005
Removed “power cord” from –UNI option for the COM128 and COM32 products.
23
December 2, 2005
Removed ION8600 “future release” options (C5, M5).
24
December 22, 2005
Modified ION6300 meter type description. Corrected description for CBL-8X00-IOE15FT.
25
January 12, 2006
Added RMICAN options for ION8600. Removed 8300/8400/8500 sections.
26
April 19, 2006
Description for ION8600 current input option "E" corrected to 10A.
Added ION6200 RMD without cable option.
27
May 2006
Added ION8800 product
28
June 2006
Schneider Electric rebranding. Added new brand labels for Square D and Merlin Gerin meters.
Removed MGT options from ION7700 product, per MGT Obsolescence Bulletin.
Fixed ION8600 description for Ethernet Fiber and onboard I/O options.
29
July 2006
Add OFGEM option to ION7550 and ION7650
30
August 2006
Schneider Electric rebranding. Added new brand labels for Square D and Merlin Gerin meters.
31
September 2006
New comm card for ION8600 (supports 56k modem)
32
October 2006
Removed 3000 series meters
33
November 2006
Added RMICAN options to ION7550 / ION7650
Removed DOC-UGUIDE-204 and DOC-UGUIDE-205 from ION Enterprise Documentation section
34
February 2007
Added note to OPTICAL-PROBE-USB part description
35
April 2007
Added ION8800 IRIG-B options. Updated ION Enterprise part numbers (version 5.6). Improved description of
cable options for 8600 I/O Expander.
36
July 2007
Corrected description of ION8600 current input option “E”. (upper limit on accuracy should be 10A RMS)
37
November 2007
New communications card options for ION7550/ION7650. Minor textual changes for ION Enterprise product.
Removed all DOC-BINDER and DOC-UGUIDE part numbers.
38
December 2007
Added "IEC 61000-4-30 Class A measurements" description to ION7650 Special Options "E" and "F".
39
March 2008
Add new communications card options to ION7550 RTU (same change as for the ION7550/ION7650).
40
May 2008
Removed CTs, VTs and terminal blocks. Removed ION7700 product line (obsolete).
41
July 2008
Changed description of brand code “M” from “Merlin Gerin” to “Schneider Electric”.
42
September 2008
Removed COM32 and COM128 products. Minor change to the ION8600 C1 communications option description.
43
January 2009
O2 initiative changes (reduced option set for the ION7300 series and ION7550/ION7650). Made the Power
Measurement brand obsolete and changed it to Schneider Electric.
44
July 2009
ION Enterprise 5.6 information exchanged for ION Enterpise 6.0.
Rev date: January 2009
Page 4 of 23
70052-0188-43
Product Part Number Guide
Contents
HARDWARE .................................................................................................................................... 7
ION8800 ........................................................................................................................................................ 7
ION8800 Comm & I/O module ................................................................................................................................ 8
ION8800 Related Items .......................................................................................................................................... 8
ION8600 ........................................................................................................................................................ 9
ION8600 I/O Expander* ........................................................................................................................................ 10
ION8600 Related Items* ....................................................................................................................................... 10
ION7650 ...................................................................................................................................................... 11
ION7550 ...................................................................................................................................................... 12
ION7550 RTU.............................................................................................................................................. 13
ION7550 / 7650 Comm Card* ............................................................................................................................... 14
ION7550/7650 Expansion I/O ............................................................................................................................... 14
External I/O Boards and Modules ......................................................................................................................... 14
ION7550 and ION7650 Related Items .................................................................................................................. 14
ION7350 ...................................................................................................................................................... 15
ION7330 ...................................................................................................................................................... 16
ION7300 ...................................................................................................................................................... 17
ION7300 Remote Display ..................................................................................................................................... 18
External I/O Boards and Modules ......................................................................................................................... 18
ION7300 Series Related Items ............................................................................................................................. 18
ION6200 ...................................................................................................................................................... 19
ION6200 Remote Display ..................................................................................................................................... 19
Cable for ION6200 Remote Display...................................................................................................................... 19
ION6200 Stocking Orders ........................................................................................................................... 20
ION6200 Meter Base ............................................................................................................................................ 20
ION6200 Option Card ........................................................................................................................................... 20
ION6200 Power Supply ............................................................................................................................... 20
SOFTWARE................................................................................................................................... 21
PowerLogic ION Enterprise 6.0................................................................................................................... 21
PowerLogic ION Enterprise 6.0 Server Licensing ................................................................................................. 21
PowerLogic ION Enterprise 6.0 Client Licensing .................................................................................................. 21
SQL Server 2005 Products ................................................................................................................................... 21
New Purchases..................................................................................................................................................... 21
Options ................................................................................................................................................................. 21
Upgrades for ION Enterprise ................................................................................................................................ 21
PowerLogic ION Enterprise documentation .......................................................................................................... 21
Appendix A: ION8600 Custom Nameplate ................................................................................. 22
Rev date: January 2009
Page 5 of 23
70052-0188-43
Product Part Number Guide
HARDWARE
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION8800.
Feature
Form
Current
Voltage
Power
System
Comm
Onboard I/O
Brand
Model
Security
Set
Factor
inputs
inputs
supply
Freq
module
& Comm
8800
0
B
ION8800
Brand
Model
Feature Set
Memory / Form
Factor
Current Inputs
Voltage Inputs
Power Supply
System Frequency
Comm Module
(field serviceable)
Onboard I/O and
Comms (not field
serviceable, part of
base unit)
Security
Special Order
Order
Code
M
P
8800
A
B
C
1
2
C
E
0
B
5
6
Z0
A0
C1
D1
E0
F0
M1
A
B
C
D
E
0
1
A
C
Special
Order
Description
Schneider Electric Branded
Schneider Electric Branded
ION8800 IEC/DIN 43862 19” rack mount series meter with integrated display, U1-U3 wide-range voltage inputs
(57-288 VAC L-N or 99-500 VAC L-L). I1-I3 current inputs with additional I4. Supports ION, Modbus-RTU, DNP
3.0 and DLMS protocols. English and French documentation ships with every meter. For onboard I/O see
comments below.
Feature Set B + power quality analysis (waveforms and transient capture with 1024 samples/cycle resolution)
Feature Set C + EN50160 compliant power quality monitoring
Basic Tariff/Energy meter
10 MB logging memory, Essailec connectors
5 MB logging memory, Essailec connectors
(I1-I3): Configured for 5A nominal, 10A full scale, 14 Amp fault capture, 0.005A starting current
(I1-I3): Configured for 1A nominal, 10A full scale, 14 Amp fault capture, 0.001A starting current
(U1-U3): Autoranging (57-288 VAC L-N or 99-500 VAC L-L)
Single phase power supply: 85-240 VAC ±10% (47-63 Hz) or 110-270 ±10% VDC
Calibrated for 50 Hz systems
Calibrated for 60 Hz systems
No Comm Module – Meter includes Base Onboard I/O and Comms (see below for details)
Std. comms: 1 RS-232/RS-485 port, **1 RS-485 port (COM2)
Std. comms AND 10BASE-T Ethernet (RJ-45), 56k universal internal modem (RJ-11)
Std. comms AND 10BASE-T Ethernet (RJ-45) / 10BASE-FL Ethernet Fiber, 56k universal internal modem
(RJ-11)
Std. comms AND 10BASE-T Ethernet (RJ-45)
Std. comms AND 10BASE-T Ethernet (RJ-45) / 10BASE-FL (ST fiber optic connection)
Std. comms AND 56k universal internal modem (RJ-11)
*Base Option AND 8 Form A digital outputs, **1 RS-485 port (COM2)
*Base Option AND 8 Form A digital outputs, 3 digital inputs (20-56 VDC/AC)
*Base Option AND 8 Form A digital outputs, 3 digital inputs (80-280 VDC/AC)
*Base Option AND 1 IRIG-B time sync port, **1 RS-485 port (COM2),3 digital inputs (20-56 VDC/AC)
*Base Option AND 1 IRIG-B time sync port, **1 RS-485 port (COM2), 3 digital inputs (80-280 VDC/AC)
Password protected, no security lock
Password protected with security lock enabled
None
Tropicalization treatment applied
*All Onboard I/O and Comms Base Option includes: 4 Form C solid-state digital outputs, 1 Form C mechanical relay output, one IEC1107 optical
communications port, two IEC1107 style optical pulsing ports.
**Channel COM2 is available on the port at the back of the meter OR on the Comm Module (if installed). You must select which terminals your
communications wiring is connected to during meter setup.
Rev date: January 2009
Page 7 of 23
70052-0188-43
Product Part Number Guide
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION8800 Communications
module.
Comm Module
P880C
ION8800
Comm & I/O
module
Comm Module
Special Order
Type
Special Order
Order
Code
880C
A0
C1
D1
E0
F0
M1
A
C
Description
ION8800 Communications module for field retrofit installations
Std. comms: 1 RS-232/RS-485 port, **1 RS-485 port (COM2)
Std. comms AND 10BASE-T Ethernet (RJ-45), 56k universal internal modem (RJ-11).
Std. comms AND 10BASE-T Ethernet (RJ-45) / 10BASE-FL Ethernet Fiber, 56k universal internal modem
(RJ-11).
Std. comms AND 10BASE-T Ethernet (RJ-45).
Std. comms AND 10BASE-T Ethernet (RJ-45) / 10BASE-FL (ST fiber optic connection).
Std. comms AND 56k universal internal modem (RJ-11)
None
Tropicalization treatment applied
**Channel COM2 is available on the port at the back of the meter OR on the Comm Module (if installed). You must select which terminals your
communications wiring is connected to during meter setup.
ION8800 Related Items
BATT-REPLACE-8XXX
RACK-8800-RAW
IEC-OPTICAL-PROBE
CD-TECHDOC
Rev date: January 2009
Replacement batteries for the ION8600 or ION8800, quantity 10
IEC/DIN 34862 19” Rack with female mating voltage/current and I/O blocks unassembled.
IEC 61107 compliant Optical Probe (DB-9) for use with ION8800 meters
Compact disc containing the latest version of technical documentation for ION hardware and software products.
Page 8 of 23
70052-0188-43
Product Part Number Guide
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION8600.
Brand
Model
Feature set Form Factor Current inputs Voltage inputs Power supply System Freq
Comm
I/O
Security
8600
0
ION8600
Brand
Model
Feature Set
Form Factor
Current Inputs
Voltage Inputs
Power Supply
Order
Code
S
P
M
8600
A
B
C
0
1
2
3
N
4
5
6
7
8
9
C
E
0
E
G
System Frequency
Communications
H
J
5
6
A0
C1
C2
E0
F0
M1
Onboard I/O
A
B
Security
0
1
Special Order
3
4
A
B
K
L
Special Order
Description
Square D branded
Schneider Electric branded
Schneider Electric branded
ION8600 Advanced Revenue Meter
10MB memory, 50 data recorders (800 channels), waveform recorders, transient detection, flicker,
interharmonics
4MB memory, 20 data recorders (320 channels), MODBUS Mastering, additional serial port
2MB memory, 2 data recorders (32 channels), sag/swell detection
* Form 9S Base: 57-277 V (autoranging) 3-Element, 4-Wire
Form 35S Base: 120-480 V (autoranging) 2-Element, 3-Wire
* Form 36S Base: 57-277 V (autoranging) 2 1/2-Element, 4-Wire
* Form 39S with neutral current input (15 Terminal Base): 57-277 V (autoranging) 3-Element, 4-Wire
* Form 76S with neutral current input (15 Terminal Base): 57-277 V (autoranging) 2 1/2-Element, 4-Wire
Form 9 FT21 Switchboard (meter + case) with break out panel
Form 35 FT21 Switchboard (meter + case) with break out panel
Form 36 FT21 Switchboard (meter + case) with break out panel
Form 9 FT21 Switchboard (meter + case) with break out cable
Form 35 FT21 Switchboard (meter + case) with break out cable
Form 36 FT21 Switchboard (meter + case) with break out cable
5 Amp nominal, 20 Amp full scale (50 Amp fault capture, start at 0.005A, accurate from 0.05 - 20A RMS)
1 Amp nominal, 10 Amp full scale (24 Amp fault capture, start at 0.001A, accurate from 0.01 - 10A RMS)
Standard (see Form Factor above)
Form 9S, 36S, 39S, 76S (socket) and Form 9, 36 (FT21 switchboard): 120-277 VAC. Form 35S (socket) and
Form 35 (FT21 switchboard): 120-480 VAC. Powered from the meter's voltage connections.
Form 9S, 36S (socket) and Form 9, 36 (FT21 switchboard): 57-70 VAC. Powered from the meter's voltage
connections. NOT AVAILABLE on Form 35S and Form 35 - you must select the auxiliary power pigtail.
Auxiliary Power Pigtail: 65-120 VAC or 80-160 VDC (power from external source)
Auxiliary Power Pigtail: 160-277 VAC or 200-350 VDC (power from external source)
Calibrated for 50 Hz systems - NOT AVAILABLE with RMICAN or RMICAN-SEAL options
Calibrated for 60 Hz systems
Infrared port, RS-232/RS-485 port, RS-485 port
Infrared Optical port, Ethernet (10BASE-T), 56k universal internal modem (RJ-11), RS-232/485 port,
RS-485 port (note the RS-232/485 and RS-485 ports are not available with Feature Set C).
Same as C1, but with RJ-31 connector for the modem
Infrared Optical port, Ethernet (10BASE-T), RS-232/485 port, RS-485 port (note this port is not available with
Feature Set C)
Infrared Optical port, Ethernet (10BASE-FL), RS-232/485 port, RS-485 port (note this port is not available with
Feature Set C)
This option is not available with FT21 switchboard form factors (Form Factor options 4 through 9).
This option is not available with the onboard I/O option.
Infrared Optical port, 56k universal internal modem (RJ-11), RS-232/485 port, RS-485 port (note this port is not
available with Feature Set C)
None
4 Form C (KYZ) digital outputs and 3 Form A digital inputs
This option is not available with Ethernet Fiber (10BASE-FL) communications option.
Password protected, no security lock - NOT AVAILABLE in Canada
Password protected with security lock enabled (requires removal of outer cover to configure billing parameters)
- NOT AVAILABLE in Canada
RMICAN (Measurement Canada approved, security lock enabled)
** RMICAN-SEAL (Measurement Canada approved, factory sealed, and security lock enabled)
None
IRIG-B GPS time synchronization port
*** Customer supplied template (frameworks) installed at the factory
*** Customer supplied template (frameworks) and IRIG-B GPS time synchronization port
To add custom text to your meter's nameplate label, fill out the ION8600 Custom Nameplate form and submit it with your order.
* For Measurement Canada approved meters, allowable voltage input range is 69-277 VAC.
** A filled-out ION8600 RMICAN-SEAL Checklist must accompany each RMICAN-SEAL meter order.
*** For Special Order “K” and “L”, you must also order the part number CUST-TEMP-SETUP (see ION8600 Related Items section). When the
template (framework) is received, the factory will issue a 5-digit code that will be appended to the ION8600 part number.
Rev date: January 2009
Page 9 of 23
70052-0188-43
Product Part Number Guide
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your I/O Expander.
Brand
I/O Expander
I/O Option
Cable Length
P
850E
ION8600 I/O
Expander*
Brand
Digital/Analog I/O
Order
Code
Description
P
Schneider Electric brand
I/O Expander for ION8600 meters: Inputs and Outputs for energy pulsing, control, energy counting, status
monitoring, and analog interface to SCADA.
I/O Option
A
External I/O box with 8 digital inputs and 8 digital outputs (4 Form A, 4 Form C)
B
External I/O box with 8 digital inputs and 4 digital outputs (4 Form C) and 4 analog outputs (0 to 20mA)
C
External I/O box with 8 digital inputs and 4 digital outputs (4 Form C) and 4 analog outputs (-1mA to 1mA)
External I/O box with 8 digital inputs and 4 digital outputs (4 Form C) and 4 analog outputs (two -1 to 1 mA, and
D
two 0 to 20 mA outputs)
Cable Option
0
No cable
5ft extension cable, 24-pin male to 24-pin female Molex connector (do not use on meters with the breakout
1
panel form factor option)
15ft extension cable, 24-pin male to 24-pin female Molex connector (do not use on meters with the breakout
2
panel form factor option)
6ft connector cable, 24-pin male to 14-pin male Molex connector (use only on meters with the breakout panel
3
form factor option)
* The I/O Expander is also supported on legacy meters ION8300, ION8400 and ION8500
850E
ION8600 Related Items*
A-BASE-ADAPTER-9
A-BASE-ADAPTER-35
A-BASE-ADAPTER-39
A-BASE-ADAPTER-76
OPTICAL-PROBE
OPTICAL-PROBE-USB
Form 9S to Form 9A adapter (http://www.pwrm.com/products/socket_adapters/)
Form 35S to Form 35A adapter (http://www.pwrm.com/products/socket_adapters/)
Form 39S to Form 39A adapter (http://www.pwrm.com/products/socket_adapters/)
Form 76S to Form 76A adapter (http://www.pwrm.com/products/socket_adapters/)
Serial Optical Probe (DB-9) via IR port
Serial Optical Probe (USB) via IR port. Note: This probe supports all ION meters with ANSI optical ports except
ION8600 meters manufactured before November 2006.
CBL-8X00BRKOUT 5ft Breakout Cable: 24-pin female Molex connector to one DB9 female connector for RS-232, and 2 sets of twisted pair
wires for two RS-485 port connections
CBL-8X00IOE5FT 5ft extension cable, mates with 24-pin male Molex connector from the meter to the 24-pin female Molex connector on
the I/O Expander box (not for use with breakout panel E8, F8 & G8 form factors)
CBL-8X00IOE15FT 15ft extension cable, mates with 24-pin male Molex connector from the meter to the 24-pin female Molex connector on
the I/O Expander box (not for use with breakout panel E8, F8 & G8 form factors)
CBL-8XX0-BOP-IOBOX 6ft connector cable, 24-pin male to 14-pin male Molex connector for connecting an ION8000 series meter with
breakout panel to an I/O Expander Box
CUST-TEMP-SETUP Set up (or modification) charge for customer supplied template (framework) at time of shipment
BATT-REPLACE-8XXX Replacement batteries for the ION8600, quantity 10
ION-SETUP Configuration software for ION8600 meters. Ships on a CD.
CD-TECHDOC Compact disc containing the latest version of technical documentation for ION hardware and software products.
* ION8600 related items are also supported on legacy meters ION8300, ION8400 and ION8500
Rev date: January 2009
Page 10 of 23
70052-0188-43
Product Part Number Guide
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7650.
Brand
Model
Form Factor Current inputs Voltage inputs Power supply System Freq
Comm
I/O
Security
7650
0
ION7650
Brand
Model
Form Factor
Current Inputs
Order
Code
S
P
M
7650
A0
A1
B0
B1
T0
T1
U0
U1
C
E
F
G
Voltage Inputs
Power Supply
System Frequency
Communications
0
B
C
5
6
A0
C1
D7
E0
F1
M1
I/O
Security
Special Order
A
D
E
H
K
N
P
0
1
3
4
6
A
C
E
F
Special Order
Description
Square D branded
Power Measurement branded
Schneider Electric branded
ION7650: Advanced meter with wide-range voltage inputs (57-347V line-neutral or 100-600V line-line),
transient detection, data and waveform recording. Supports ION, Modbus-RTU, and DNP 3.0 protocols.
Integrated display with front optical port, 5 MB logging memory, and 512 samples/cycle resolution.
Integrated display with front optical port, 5 MB logging memory, and 1024 samples/cycle resolution.
Integrated display with front optical port, 10 MB logging memory, and 512 samples/cycle resolution.
Integrated display with front optical port, 10 MB logging memory, and 1024 samples/cycle resolution.
Transducer (no display) version, with 5 MB logging memory, and 512 samples/cycle resolution.
Transducer (no display) version, with 5 MB logging memory, and 1024 samples/cycle resolution.
Transducer (no display) version, with 10 MB logging memory, and 512 samples/cycle resolution.
Transducer (no display) version, with 10 MB logging memory, and 1024 samples/cycle resolution.
5 Amp nominal, 20 Amp full scale current input
1 Amp nominal, 10 Amp full scale current input
Current Probe Inputs (for use with 0-1 VAC current probes; probes sold separately)
- NOT AVAILABLE with OFGEM option
Current Probe Inputs with three Universal Technic 10A clamp on CTs; meets IEC 1036 accuracy
- NOT AVAILABLE with OFGEM option
57 to 347 VAC line-to-neutral / 100 to 600 VAC line-to-line
Standard power supply (85-240 VAC, ±10%/47-63 Hz / 110-300 VDC, ±10%)
Low voltage DC power supply (20-60 VDC)
Calibrated for 50 Hz systems
Calibrated for 60 Hz systems. NOT AVAILABLE with OFGEM option
Standard communications (1 RS-232/RS-485 port, 1 RS-485 port).
Integrated display models also include 1 ANSI Type 2 optical communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45), 56k universal internal modem (RJ-11).
Ethernet and modem gateway functions each use a serial communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX Ethernet Fiber, 56k
universal internal modem (RJ-11). Ethernet and modem gateway functions each use a serial communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45).
Ethernet gateway function uses a serial communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX (SC fiber optic
connection). Ethernet gateway function uses a serial communications port.
Standard communications plus 56k universal internal modem (RJ-11).
Modem gateway function uses a serial communications port.
Standard I/O (8 digital inputs, 3 Form C relays, 4 Form A solid-state outputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 mA analog inputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four -1 to 1 mA analog outputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog outputs)
Standard I/O plus Expansion I/O card (8 additional Digital In & four 0 to 20 mA analog inputs & four 0 to 20 mA outputs)
Standard I/O plus Expansion I/O card (8 additional Digital In & four 0 to 1 Analog Inputs & four -1 to 1 mA analog
outputs)
Password protected, no hardware lock
Password protected and hardware lockable (lock enabled/disabled via jumper on comm card)
*RMICAN Measurement Canada approved, security lock enabled
*RMICAN-SEAL Measurement Canada approved, factory sealed, security lock enabled
Password protected with security lock enabled, terminal cover and UK OFGEM labels
None
Tropicalization treatment applied
EN50160 compliance monitoring and IEC 61000 4-30 Class A measurements, no tropicalization treatment
EN50160 compliance monitoring and IEC 61000 4-30 Class A measurements, with tropicalization treatment
* RMICAN approval for Delta mode sealing is not yet available. Please contact factory for details.
Rev date: January 2009
Page 11 of 23
70052-0188-43
Product Part Number Guide
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7550.
Brand
Model
Form Factor Current inputs Voltage inputs Power supply System Freq
Comm
I/O
Security
7550
0
ION7550
Brand
Model
Form Factor
Current Inputs
Order
Code
S
P
M
7550
A0
B0
T0
U0
C
E
F
G
Voltage Inputs
Power Supply
System Frequency
Communications
0
B
C
5
6
A0
C1
D7
E0
F1
M1
I/O
A
D
E
H
K
N
P
Security
Special Order
0
1
3
4
6
A
C
Special Order
Description
Square D branded
Power Measurement branded
Schneider Electric branded
ION7550: Advanced meter with wide-range voltage inputs (57-347 line-neutral or 100-600V line-line), sag/swell
detection, data and waveform recording, and 256 samples/cycle resolution. Supports ION, Modbus RTU and DNP 3.0
protocols.
Integrated display with front optical port and 5 MB logging memory
Integrated display with front optical port and 10 MB logging memory.
Transducer (no display) version, with 5 MB logging memory.
Transducer (no display) version, with 10 MB logging memory.
5 Amp nominal, 20 Amp full scale current input
1 Amp nominal, 10 Amp full scale current input
Current Probe Inputs (for use with 0-1 VAC current probes; probes sold separately)
- NOT AVAILABLE with OFGEM option
Current Probe Inputs with three Universal Technic 10A clamp on CTs; meets IEC 1036 accuracy
- NOT AVAILABLE with OFGEM option
57 to 347 VAC line-to-neutral / 100 to 600 VAC line-to-line
Standard power supply (85-240 VAC, ±10%/47-63 Hz / 110-300 VDC, ±10%)
Low voltage DC power supply (20-60 VDC)
Calibrated for 50 Hz systems
Calibrated for 60 Hz systems. NOT AVAILABLE with OFGEM option
Standard communications (1 RS-232/RS-485 port, 1 RS-485 port).
Integrated display models also include 1 ANSI Type 2 optical communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45), 56k universal internal modem (RJ-11).
Ethernet and modem gateway functions each use a serial communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX Ethernet Fiber, 56k
universal internal modem (RJ-11). Ethernet and modem gateway functions each use a serial communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45).
Ethernet gateway function uses a serial communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX (SC fiber optic
connection). Ethernet gateway function uses a serial communications port.
Standard communications plus 56k universal internal modem (RJ-11).
Modem gateway function uses a serial communications port.
Standard I/O (8 digital inputs, 3 Form C relays, 4 Form A solid-state outputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 mA analog inputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four -1 to 1 mA analog outputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog outputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs
and four 0 to 20 mA outputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 analog inputs
& four -1 to 1 mA analog outputs)
Password protected, no hardware lock
Password protected and hardware lockable (lock enabled/disabled via jumper on comm card)
*RMICAN Measurement Canada approved, security lock enabled
*RMICAN-SEAL Measurement Canada approved, factory sealed, security lock enabled
Password protected with security lock enabled, terminal cover and UK OFGEM labels
None
Tropicalization treatment applied
* RMICAN approval for Delta mode sealing is not yet available. Please contact factory for details.
ION7550 / ION7650 Comm Cards, Expansion I/O Cards and related items are listed on pages 14.
Rev date: January 2009
Page 12 of 23
70052-0188-43
Product Part Number Guide
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7550 RTU.
Brand
Model
Form Factor RTU Option Power supply Internal Use
Comm
I/O
Security
Special Order
7550
N9
9
0
ION7550 RTU
Brand
Model
Form Factor
RTU Option
Power Supply
Internal Use
Communications
Order
Code
S
P
M
7550
A0
B0
T0
U0
N9
B
C
9
A0
C1
D7
E0
F1
M1
I/O
A
D
E
H
K
N
P
Security
Special Order
Rev date: January 2009
0
A
C
Description
Square D branded
Power Measurement branded
Schneider Electric branded
ION7550 device
Integrated display with front optical port and 5 MB logging memory
Integrated display with front optical port and 10 MB logging memory.
Transducer (no display) version, with 5 MB logging memory.
Transducer (no display) version, with 10 MB logging memory.
RTU option
Standard power supply (85-240 VAC, ±10%/47-63 Hz / 110-300 VDC, ±10%)
Low voltage DC power supply (18-75 VDC)
This field for internal use only
Standard communications (1 RS-232/RS-485 port, 1 RS-485 port).
Integrated display models also include 1 ANSI Type 2 optical communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45), 56k universal internal modem (RJ-11).
Ethernet and modem gateway functions each use a serial communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX Ethernet Fiber, 56k
universal internal modem (RJ-11). Ethernet and modem gateway functions each use a serial communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45).
Ethernet gateway function uses a serial communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX (SC fiber optic
connection). Ethernet gateway function uses a serial communications port.
Standard communications plus 56k universal internal modem (RJ-11).
Modem gateway function uses a serial communications port.
Standard I/O (8 digital inputs, 3 Form C relays, 4 Form A solid-state outputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 mA analog inputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four -1 to 1 mA analog outputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog outputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs
and four 0 to 20 mA outputs)
Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 analog inputs & four -1 to 1 mA
analog outputs)
Password protected
None
Tropicalization treatment applied
Page 13 of 23
70052-0188-43
Product Part Number Guide
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7550/7650 Comm Card.
Comm Card
Type
Special Order
P765C
ION7550 / 7650
Comm Card*
Order
Code
Comm Card
Type
P765C
A0
C1
D7
E0
F1
M1
Special Order
A
C
* Firmware v350 or higher required.
Description
ION7550 / ION7650 Communications card for field retrofit installations
Standard communications (1 RS-232/RS-485 port, 1 RS-485 port).
Front optical port support for meters with integrated display.
Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45), 56k universal internal modem (RJ-11; the
modem port is shared with the front optical port). Ethernet and modem gateway functions each use a serial
communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet, 100BASE-FX Ethernet Fiber, 56k universal internal
modem (RJ-11; the modem port is shared with the front optical port).
Ethernet and modem gateway functions each use a serial communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet. Ethernet gateway function uses a serial
communications port.
Standard communications plus 10BASE-T/100BASE-TX Ethernet, 100BASE-FX Ethernet Fiber (SC fiber optic
connection). Ethernet gateway function uses a serial communications port.
Standard communications plus 56k universal internal modem (RJ-11; the modem port is shared with the front optical
port). Modem gateway function uses a serial communications port.
None
Tropicalization treatment applied
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7550/7650 I/O Card.
Expansion I/O
Type
Special Order
P760A
ION7550/7650
Expansion I/O
Order
Code
Description
I/O Card
Type
P760A
D
E
H
K
N
P
A
C
ION7550 / ION7650 Expansion I/O card for field retrofit installations
Expansion I/O card with eight digital inputs, four 0 to 1 mA analog inputs
Expansion I/O card with eight digital inputs, four 0 to 20 mA analog inputs
Expansion I/O card with eight digital inputs, four -1 to 1 mA analog outputs
Expansion I/O card with eight digital inputs, four 0 to 20 mA analog outputs
Expansion I/O card with eight digital inputs, four 0 to 20 mA analog inputs & four 0 to 20 mA outputs
Expansion I/O card with eight digital inputs, four 0 to 1 analog inputs and four -1 to 1 mA analog outputs
None
Tropicalization treatment applied
Special Order
External I/O Boards and Modules
Compatible I/O boards and modules can be ordered from the Grayhill website.
To find a distributor, visit http://grayhill.com/wherebuy/where-to-buy.html
ION7550 and ION7650 Related Items
ADPT-37XX-7500
TERMCVR-7500
M1UB10A1V-10A
P32UEP813-1000A
P32UEP815-3000A
SCT0750-005-5A
SCT1250-300-300A
CD-TECHDOC
Rev date: January 2009
Adapter plate enabling the 7550 or 7650 to fit into a 3710 or 3720 ACM panel cutout
Terminal strip cover for the 7550 or 7650
10 A / 1 VAC Universal Technic Clamp On Current Probe
1000 A / 1 VAC Universal Technic Clamp On Current Probe
3000 A / 1 VAC Universal Technic Clamp On Current Probe
5 A / 0.333 VAC Magnelabs Split Core Current Probe
300 A / 0.333 VAC Magnelabs Split Core Current Probe
Compact disc containing the latest version of technical documentation for ION hardware and software products.
Page 14 of 23
70052-0188-43
Product Part Number Guide
Brand
Model
7350
ION7350
Brand
Model
Form Factor
Form Factor
Order
Code
S
P
M
7350
A0
R0
R1
T0
T1
Current Inputs
Voltage Inputs
Power Supply
System Frequency
Communications
B
0
B
C
0
A0
C1
E0
I/O
M1
A
M
N
Security
Special Order
Rev date: January 2009
0
2
6
A
B
C
D
Current inputs Voltage inputs Power supply
B
0
System Freq
0
Comm
I/O
Security
Special Order
Description
Square D branded
Power Measurement branded
Schneider Electric branded
ION7350: Advanced power meter with basic sag/swell detection, waveform recording, harmonics (up to the
31st), high-speed data logging and automatic modem dial-out, multiport communications, 4 digital inputs and
4 digital outputs.
Integrated display, with front optical port
Transducer with RMD (remote display), with front optical port. DOES NOT support Analog Input and/or Analog
Output options.
Same as R0, but with DIN rail mounts on the transducer. DOES NOT support Analog Input and/or Analog
Output options.
Transducer (no display). Note you cannot use an RMD on this meter if you order the Analog Input and/or
Analog Output options.
Transducer (no display) with DIN rail mount. Note you cannot use an RMD on this meter if you order the
Analog Input and/or Analog Output options.
5 Amp nominal, 10 Amp full scale current input
Autoranging (50 to 347 VAC +25%)
P240 power supply (95-240VAC/47-440Hz/120-310 VDC)
P24 power supply (20 to 65 VDC)
Autoranging (50 and 60 Hz)
Two RS-485 ports.
One RS-485 EtherGate port, one RS-485 ModemGate port, 10BASE-T Ethernet (RJ-45), 33.6k universal
internal modem (RJ-11). DOES NOT support Analog Input and/or Analog Output options.
One 10BASE-T Ethernet (RJ-45) port, one RS-485 port, one RS-485 EtherGate port.. DOES NOT support
Analog Input and/or Analog Output options.
One 33.6k universal internal modem (RJ-11) port, one RS-485 port, one RS-485 ModemGate port.
No analog inputs/outputs. You must choose this option if ordering RMD remote display option (Form Factor
type "R1") or Ethernet port options (Communications types "C1" or "E0").
Four 0 to 1 mA analog inputs & four 0 to 1 mA analog outputs. NOT AVAILABLE with RMD or Ethernet options
Four 0 to 20 mA analog inputs & four 0 to 20 mA analog outputs. NOT AVAILABLE with RMD or Ethernet
options
Password protected, no hardware lock
Password protected with hardware lock enabled
Password protected with security lock enabled, terminal cover and UK OFGEM labels
None
Pre-set to MODBUS (available for Form Factor T0 and T1 only)
Tropicalization treatment applied
Tropicalization treatment applied and pre-set to MODBUS (available for Form Factor T0 and T1 only)
Page 15 of 23
70052-0188-43
Product Part Number Guide
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7330.
Brand
Model
Form Factor Current inputs Voltage inputs Power supply System Freq
Comm
I/O
Security
7330
B
0
0
ION7330
Brand
Model
Form Factor
Order
Code
S
P
M
7330
A0
R0
R1
T0
T1
Current Inputs
Voltage Inputs
Power Supply
System Frequency
Communications
B
0
B
C
0
A0
C1
E0
I/O
M1
A
M
N
Security
Special Order
0
2
3
4
6
A
B
C
D
Special Order
Description
Square D branded
Power Measurement branded
Schneider Electric branded
ION7330: Advanced power meter with over 200 high accuracy, 3-phase measurements, data logging, multiport
communications, 4 digital inputs and 4 outputs.
Integrated display, with front optical port
Transducer with RMD (remote display), with front optical port. DOES NOT support Analog Input and/or Analog
Output options. Not available with Security options RMICAN or RMICAN-SEAL.
Same as R0, but with DIN rail mounts on the transducer. DOES NOT support Analog Input and/or Analog
Output options. Not available with Security options RMICAN or RMICAN-SEAL.
Transducer (no display). Note you cannot use an RMD on this meter if you order the Analog Input and/or
Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL.
Transducer (no display) with DIN rail mount. Note you cannot use an RMD on this meter if you order the
Analog Input and/or Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL.
5 Amp nominal, 10 Amp full scale current input
Autoranging (50 to 347 VAC +25%)
P240 power supply (95-240VAC/47-440Hz/120-310 VDC)
P24 power supply (20 to 65 VDC)
Autoranging (50 and 60 Hz)
Two RS-485 ports.
One RS-485 EtherGate port, one RS-485 ModemGate port, 10BASE-T Ethernet (RJ-45), 33.6k universal
internal modem (RJ-11). DOES NOT support Analog Input and/or Analog Output options.
One 10BASE-T Ethernet (RJ-45) port, one RS-485 port, one RS-485 EtherGate port.. DOES NOT support
Analog Input and/or Analog Output options.
One 33.6k universal internal modem (RJ-11) port, one RS-485 port, one RS-485 ModemGate port.
No analog inputs/outputs. You must choose this option if ordering RMD remote display option (Form Factor
type “R0” or "R1") or Ethernet port options (Communications types "C1" or "E0").
Four 0 to 1 mA analog inputs & four 0 to 1 mA analog outputs. NOT AVAILABLE with RMD or Ethernet options
Four 0 to 20 mA analog inputs & four 0 to 20 mA analog outputs. NOT AVAILABLE with RMD or Ethernet
options
Password protected, no hardware lock
Password protected with hardware lock enabled
RMICAN Measurement Canada approved
**RMICAN-SEAL Measurement Canada approved, factory sealed
Password protected with security lock enabled, terminal cover and UK OFGEM labels
None
Pre-set to MODBUS (available for Form Factor T0 and T1 only).
Not available with Security options RMICAN or RMICAN-SEAL.
Tropicalization treatment applied
Tropicalization treatment applied and pre-set to MODBUS (available for Form Factor T0 and T1 only).
Not available with Security options RMICAN or RMICAN-SEAL.
** A filled-out ION7300 Series RMICAN-SEAL Checklist must accompany each RMICAN-SEAL meter order.
Rev date: January 2009
Page 16 of 23
70052-0188-43
Product Part Number Guide
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7300.
Brand
Model
Form Factor Current inputs Voltage inputs Power supply System Freq
Comm
I/O
Security
7300
B
0
0
ION7300
Brand
Model
Form Factor
Order Code
S
P
M
7300
A0
R0
R1
T0
T1
Current Inputs
Voltage Inputs
Power Supply
System Frequency
Communications
I/O
B
0
B
C
0
A0
E0
P0
A
M
N
Security
Special Order
0
2
3
4
6
A
B
C
D
Special Order
Description
Square D branded
Power Measurement branded
Schneider Electric branded
ION7300: Advanced power meter with over 100 high accuracy, 3-phase measurements, 1 RS-485
communication port and 4 digital outputs. Supports ION and Modbus-RTU protocols.
Integrated display, with front optical port
Transducer with RMD (remote display), with front optical port. DOES NOT support Analog Input and/or Analog
Output options. Not available with Security options RMICAN or RMICAN-SEAL.
Same as R0, but with DIN rail mounts on the transducer. DOES NOT support Analog Input and/or Analog
Output options. Not available with Security options RMICAN or RMICAN-SEAL.
Transducer (no display). Note you cannot use an RMD on this meter if you order the Analog Input and/or
Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL.
Transducer (no display) with DIN rail mount. Note you cannot use an RMD on this meter if you order the
Analog Input and/or Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL.
5 Amp nominal, 10 Amp full scale current input
Autoranging (50 to 347 VAC +25%)
P240 power supply (95-240VAC/47-440Hz/120-310 VDC)
P24 power supply (20 to 65 VDC)
Autoranging (50 and 60 Hz)
One RS 485 port
One RS 485 port, one 10BASE-T Ethernet (RJ-45)
One RS 485 port, one Profibus communications. Available only on Integrated Display model (form factor “A0”).
No analog inputs/outputs. You must choose this option if ordering RMD remote display options (Form Factor
type "R0" or “R1”), or Ethernet or Profibus port options (Communications options "E0" or “P0”).
Four 0 to 1 mA analog inputs & four 0 to 1 mA analog outputs. NOT AVAILABLE with RMD or Ethernet options
Four 0 to 20 mA analog inputs & four 0 to 20 mA analog outputs. NOT AVAILABLE with RMD or Ethernet
options
Password protected, no hardware lock
Password protected with hardware lock enabled
RMICAN Measurement Canada approved
**RMICAN-SEAL Measurement Canada approved, factory sealed
Password protected with security lock enabled, terminal cover and UK OFGEM labels
None
Pre-set to MODBUS (available for Form Factor T0 and T1 only).
Not available with Security options RMICAN or RMICAN-SEAL.
Tropicalization treatment applied
Tropicalization treatment applied and pre-set to MODBUS (available for Form Factor T0 and T1 only).
Not available with Security options RMICAN or RMICAN-SEAL.
** A filled-out ION7300 Series RMICAN-SEAL Checklist must accompany each RMICAN-SEAL meter order.
Rev date: January 2009
Page 17 of 23
70052-0188-43
Product Part Number Guide
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7300/ION7330/ION7350
Remote Modular Display.
Brand
Display Type
ION7300 Remote
Display
Order
Code
Description
Brand
S
Square D branded
P
Power Measurement branded
M
Schneider Electric branded
Display Type*
RMD-7300
ION7300 Remote Modular Display with 6 ft. DB25 cable
RMD-7330
ION7330 Remote Modular Display with 6 ft. DB25 cable
RMD-7350
ION7350 Remote Modular Display with 6 ft. DB25 cable
* Remote Modular Display cannot be used with TRAN units that contain an analog I/O card
External I/O Boards and Modules
Compatible I/O boards and modules can be ordered from the Grayhill website.
To find a distributor, visit http://grayhill.com/wherebuy/where-to-buy.html
ION7300 Series Related Items
GSKT
OPTICAL-PROBE
OPTICAL-PROBE-USB
ADPT-37XX-73XX
RAP
ACCUREPORT
TERMCVR-73XX
CD-TECHDOC
Rev date: January 2009
Water resistant gasket
Serial Optical Probe (DB-9) via IR port
Serial Optical Probe (USB ) via IR port
Adapter plate enabling an ION73xx to fit a 3710/3720 panel cutout
Adapter plate to mount an ION73xx in an ANSI C39.1 (round hole) cutout
Factory generated accuracy graph
Terminal strip cover
Compact disc containing the latest version of technical documentation for ION hardware and software products.
62H
Page 18 of 23
70052-0188-43
Product Part Number Guide
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION6200.
Brand
Model
Form Factor Current inputs Voltage inputs Power supply System Freq
Comm
I/O
Security
6200
A
0
0
Order
Code
ION6200
Brand
Model
Form Factor
S
P
M
6200
A0
R1
R2
R3
T1
M0
N1
N2
N3
Current Inputs
Voltage Inputs
Power Supply
System Frequency
Communications
I/O
Security
Measurement
Package
A
0
B
C
D
0
Z0
A0
A
B
0
2
3
4
N
P
R
Measurements
Description
Square D branded
Schneider Electric branded
Schneider Electric branded
ION6200 Meter Kit: ION6200 Meter base, Options Card and Power Supply.
Integrated display model
Transducer model with DIN rail mount, Remote Display and 14-ft cable (RJ-11, 6 conductor, 26 gauge).
Transducer model with DIN rail mount, Remote Display and 6-ft cable (RJ-11, 6 conductor, 26 gauge).
Transducer model DIN rail mount, Remote Display and 30-ft cable (RJ-11, 6 conductor, 26 gauge).
Transducer model with DIN rail mount (requires Comms or pulse outputs)
MegaWatt option on Integrated Display model. Not available with Security options RMICAN or RMICAN-SEAL.
MegaWatt option on Transducer model with DIN rail mount, Remote Display and 14-ft cable
(RJ-11, 6 conductor, 26 gauge). Not available with Security options RMICAN or RMICAN-SEAL.
MegaWatt option on Transducer model with DIN rail mount, Remote Display and 6-ft cable
(RJ-11, 6 conductor, 26 gauge). Not available with Security options RMICAN or RMICAN-SEAL.
MegaWatt option on Transducer model with DIN rail mount, Remote Display and 30-ft cable
(RJ-11, 6 conductor, 26 gauge). Not available with Security options RMICAN or RMICAN-SEAL.
10 Amp current inputs (12 Amp max)
Autoranging (57-400 VAC L-N / 99-690 VAC L-L)
P620PB: Standard Plug-in Power Supply (100-240 VAC / 50-60 Hz or 110-300 VDC)
P620PC: Low voltage DC Plug-in Power Supply (20-60 VDC)
P620PD: 480 V power supply (480 VAC, 60Hz)
Calibrated for use with 50 Hz or 60 Hz systems
No communications
Single RS-485 port (supports Modbus RTU protocol and ION-compatible PML protocol)
No I/O
This option activates the two Form A digital outputs for kWh, kVARh or kVARh energy pulsing
No hardware lock (setup is password protected)
RMANSI: Revenue Meter approved for use in the United States (ANSI C12.16 approved; meets ANSI C12.20
class 0.5 accuracy at 23°C; 10A current inputs only)
RMICAN: Measurement Canada approved revenue meter for use in Canada (10A current inputs only)
**RMICAN-SEAL: Factory-sealed and Measurement Canada approved revenue meter
Standard Measurements (Volts/Amps per phase and avg)
Enhanced Package #1 (Standard Measurements plus Energy/Power total, Frequency, Power Factor total,
Neutral Current
Enhanced Package #2 (all measurements)
** A filled-out ION6200 RMICAN-SEAL Checklist must accompany each RMICAN-SEAL meter order.
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION6200 Remote Display.
Brand
Model
Display Type Cable Length
620D
ION6200
Remote Display
Brand
Model
Display Type
Cable Length
Order
Code
S
P
M
620D
R
N
0
1
Description
Square D branded
Schneider Electric branded
Schneider Electric branded
Remote Display Unit for the ION6200 Transducer meter base
Standard display
MegaWatt option — for use with Transducer meter base with MegaWatt option.
- NOT AVAILABLE for RMICAN or RMICAN-SEAL meters
No cable
14-ft cable for connecting Remote Display Unit to the ION6200 Transducer meter base.
Cable for ION6200 Remote Display
P620C1
P620C2
P620C3
Rev date: January 2009
14-ft cable for connecting Remote Display Unit to the ION6200 Transducer meter base.
6-ft cable for connecting Remote Display Unit to the ION6200 Transducer meter base.
30-ft cable for connecting Remote Display Unit to the ION6200 Transducer meter base.
Page 19 of 23
70052-0188-43
Product Part Number Guide
ION6200 Stocking Orders
The ION6200 is made up of three separate components: the Meter Base, Option Card and Power Supply. Each of these
components are required to create one complete ION6200.
The following order scheme is intended for customers who purchase for stocking purposes. For stocking orders, customers have the
option of purchasing quantities of the separate components (i.e. meter base, option card & power supply) and then mixing and
matching them as required to serve their needs.
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION6200 Meter Base.
Brand
Model
Form Factor Current inputs Voltage inputs System Freq
620B
A
0
0
ION6200 Meter
Base
Order
Code
Brand
S
P
M
Model
Form Factor
620B
A0
M0
T1
Current Inputs
Voltage Inputs
System Freq
A
0
0
Description
Square D branded
Schneider Electric branded
Schneider Electric branded
ION6200 meter base
Integrated Display on meter base
MegaWatt option on meter base with Integrated Display
- NOT AVAILABLE for RMICAN or RMICAN-SEAL meters
Transducer meter base with DIN rail mounts
- NOT AVAILABLE for RMICAN or RMICAN-SEAL meters
10 Amp current inputs (12 Amp max)
Auto-ranging (57-400 VAC L-N / 99-690 VAC L-L)
Calibrated for use with 50 Hz or 60 Hz systems
Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION6200 Option Card.
Model
Comm
I/O
Security
Measurements
P620K
ION6200 Option
Card
Order
Code
Model
Communications
P620K
Z0
A0
A
B
0
2
I/O
Security
3
4
N
P
Measurement
Options
R
Description
Option Card to activate basic and advanced features on the ION6200.
No communications
Single RS-485 port (supports Modbus RTU protocol and PML protocol)
No I/O
This option activates the two Form A digital outputs for kWh, kVARh or kVARh energy pulsing
No hardware lock (setup is password protected)
RMANSI: Revenue Meter approved for use in the United States (ANSI C12.16 approved; meets ANSI C12.20
class 0.5 accuracy at 23°C; 10A current inputs only)
RMICAN: Measurement Canada approved revenue meter for use in Canada (10A current inputs only)
RMICAN-SEAL: Factory-sealed and Measurement Canada approved revenue meter
Standard Measurements (Volts/Amps per phase and avg)
Enhanced Package #1 (Standard Measurements plus Energy/Power total, Frequency, Power Factor total,
Neutral Current)
Enhanced Package #2 (all measurements)
ION6200 Power Supply
P620PB
P620PC
P620PD
Rev date: January 2009
Standard Plug-in Power Supply (100-240 VAC / 50-60 Hz or 110-300 VDC) for the ION6200.
Low voltage DC Plug-in Power Supply (20-60 VDC) for the ION6200.
480V power supply (480VAC, 60Hz) for the ION6200.
Page 20 of 23
70052-0188-43
Product Part Number Guide
SOFTWARE
PowerLogic ION Enterprise 6.0
PowerLogic ION Enterprise 6.0 Server Licensing
Every new system must be ordered with one (1) IONE60-BASE software and a minimum of five (5) IONE60-DL device licences. The IONE60-BASE
software includes all PowerLogic ION Enterprise applications (Communications, database components, Vista, Reporter, WebReach, Virtual
Processor, OPC Client), for installation and use on a single PC (server or workstation).
Beyond the first 5 devices, the customer has the ability to order the exact number of devices required for the system. As the customer adds devices,
additional device licences can be ordered (minimum 5 devices).
PowerLogic ION Enterprise 6.0 Client Licensing
A client licence is required for all PCs running PowerLogic ION Enterprise applications (e.g. Vista, Reporter, Management Console, or any
combination of these), or PCs that use Terminal Services or Remote Desktop to access the ION Enterprise Server. Previous licences are
non-transferable.
SQL Server 2005 Products
We now have the option to bundle Microsoft SQL Server 2005 in conjunction with ION software. The IONE-SQL-2005 product is a 1 CPU licence for
SQL Server 2005 Standard Edition. For each additional CPU used by SQL Server, an additional IONE-SQL-2005-CPU is required. These products
are for use only with licensed copies of ION Enterprise or ION EEM.
New Purchases
IE60-BASE-ENG
PowerLogic ION Enterprise base software (English, DVD)
IE60-DL-S(1)
Individual Device Licence for High-End Devices, compatible with all supported device types
IE60-DL-M (1)
Individual Device Licence for Mid-Range Devices, compatible with all supported device types
IE60-DL-E (1)
Individual Device Licence for Entry-Range Devices, compatible with Entry-Range devices
IE60-CL(2)
PowerLogic ION Enterprise Client Licence
Options
IONE-SQL-2005
Integrated SQL Server 2005 Standard Edition (for use with ION Enterprise only) – Processor Licence for 1 CPU
IONE-SQL-2005-CPU
Additional CPU Licence for Integrated SQL Server 2005
IONE-OPC-V1
OPC Server support for ION Enterprise
IONE-PQDIF-V1
PQDIF Exporter Module for ION Enterprise
Upgrades for ION Enterprise1
IE60-BASE-ENG-UPG
PowerLogic ION Enterprise base software (English, DVD) - upgrade from v5.5 SP2 or later
IE60-DL-S-UPG
Individual Device Licence Upgrade for High-End Devices, compatible with all supported device types
IE60-DL-M-UPG
Individual Device Licence Upgrade for Mid-Range Devices, compatible Mid- and Entry-Range devices
IE60-DL-E-UPG
Individual Device Licence Upgrade for Entry-Range Devices, compatible with Entry-Range devices
IE60-CL-UPG
PowerLogic ION Enterprise Client Licence - upgrade
1
Upgrades only apply to ION Enterprise 5.5/5.6
PowerLogic ION Enterprise documentation
CD-TECHDOC Compact disc containing the latest version of technical documentation for ION hardware and software products.
(1) An appropriate device licence (IE60-DL-S, DL-M, or DL-E) is required for each meter or device connected to your PowerLogic ION Enterprise
system. Device licences have a minimum order quantity of ten (10).
(2) A client licence is required for each workstation that is used to connect to your primary PowerLogic ION Enterprise server.
* Please refer to Schneider Electric sales representative for full pricing and part numbers information.
Rev date: January 2009
Page 21 of 23
70052-0188-43
Product Part Number Guide
Appendix A: ION8600 Custom Nameplate
If you would like to add custom text to your meter's nameplate label, fill out this form and submit it with your P.O.
Customer:
P.O.#:
P.O. line#:
Quantity:
Mult by
FM 35S
V~ 120
-480
W 3WD
M8G12345678900000
PQ-9903A000-00
DEMAND
RESET
17 characters
maximum
*Meter Tag Number (required):
Bar Code 39:
17 characters
maximum
Bar Code Interpretation Line:
PQ9903A000-00
Buyer Specified
(Positions 13 to 17)
Manufacturer Data Code (Position 3)
Meter Specification Data Code (Position 1 & 2)
ZY
Form 9S
0.0V
TA2.5
M8
Form 35S
0.0V
TA2.5
M9
Form 36S
0.0V
TA2.5
2C
Form 39S
0.0V
TA2.5
2D
Form 76S
0.0V
TA2.5
Manufacturer Serial Number
(positions 4 to 12)
These fields are set to the
Manufacturer’s serial number unless
specified by the customer.
Kt: 0.0
Kt: 0.0
Kt: 0.0
Kt: 0.0
Kt: 0.0
3Ф4W
3Ф3W
3Ф4W
3Ф4W
3Ф4W
3EL
2EL
2½EL
3EL
2½EL
*The METER TAG number is a mandatory requirement for this checklist; each meter to be sealed must have a unique tag number.
Notes:
Rev date: January 2009
Page 22 of 23
70052-0188-43
Download