Product Part Number Guide September 2009 [Interim copy] Product Part Number Guide How to print single pages 1. 2. Place your mouse cursor on the page you want to print out. From the menu File, select Print. In the Print dialog box under Page range, select Current page. Click OK. (do not use the Print icon on the toolbar, otherwise all the pages in the entire document will be printed) How to determine your meter part number 1. 2. 3. Select one Order Code from each of the ordering categories. Combine these order codes to form the part number for your particular meter configuration. Use that part number when you fill out your purchase order. Brand Example part number Model S 7 Form Factor 6 5 0 Current Voltage inputs inputs A 0 C 0 Power supply B 6 System Freq A 0 Comm A 0 I/O Security Special Order A In the above example, the part number P7650A0C0B6E0A0A corresponds to: Brand: Model: S 7650 Form Factor: A0 Current Inputs: Voltage Inputs: Power Supply: System Frequency: Communications: Onboard I/O: Security: Special Order: C 0 B 6 A0 A 0 A Rev date: January 2009 Square D brand ION7650 power meter Integrated display with front optical port, 5 MB logging memory, and 512 samples/cycle resolution. 5A nominal, 20A full scale current inputs 57 to 347 VAC line-to-neutral / 100 to 600 VAC line-to-line 85-240 VAC, ±10%/47-63 Hz/110-300 VDC, ±10% Calibrated for 60 Hz systems 1 RS-232/RS-485 port, 1 RS-485 port, infrared optical port. 8 digital inputs, 3 Form C relays, 4 Form A solid-state outputs Password protected, no hardware lock None Page 3 of 23 70052-0188-43 Product Part Number Guide Revision History Rev 20 Date Description of change September 7, 2005 Added PQDIF Exporter add-on part numbers to ION Enterprise 5.5 section. Added RS-485/Modbus communications option to ION6300. Modified ION Wireless Repeater part number and ION6100 & ION6300 options code scheme (combined last three option code characters into one field). Replaced ION8300/8400/8500 technical documentation/user guide part numbers with ION8600 part numbers. 21 September 19, 2005 Part number corrections for accessories. 22 October 12, 2005 Removed “power cord” from –UNI option for the COM128 and COM32 products. 23 December 2, 2005 Removed ION8600 “future release” options (C5, M5). 24 December 22, 2005 Modified ION6300 meter type description. Corrected description for CBL-8X00-IOE15FT. 25 January 12, 2006 Added RMICAN options for ION8600. Removed 8300/8400/8500 sections. 26 April 19, 2006 Description for ION8600 current input option "E" corrected to 10A. Added ION6200 RMD without cable option. 27 May 2006 Added ION8800 product 28 June 2006 Schneider Electric rebranding. Added new brand labels for Square D and Merlin Gerin meters. Removed MGT options from ION7700 product, per MGT Obsolescence Bulletin. Fixed ION8600 description for Ethernet Fiber and onboard I/O options. 29 July 2006 Add OFGEM option to ION7550 and ION7650 30 August 2006 Schneider Electric rebranding. Added new brand labels for Square D and Merlin Gerin meters. 31 September 2006 New comm card for ION8600 (supports 56k modem) 32 October 2006 Removed 3000 series meters 33 November 2006 Added RMICAN options to ION7550 / ION7650 Removed DOC-UGUIDE-204 and DOC-UGUIDE-205 from ION Enterprise Documentation section 34 February 2007 Added note to OPTICAL-PROBE-USB part description 35 April 2007 Added ION8800 IRIG-B options. Updated ION Enterprise part numbers (version 5.6). Improved description of cable options for 8600 I/O Expander. 36 July 2007 Corrected description of ION8600 current input option “E”. (upper limit on accuracy should be 10A RMS) 37 November 2007 New communications card options for ION7550/ION7650. Minor textual changes for ION Enterprise product. Removed all DOC-BINDER and DOC-UGUIDE part numbers. 38 December 2007 Added "IEC 61000-4-30 Class A measurements" description to ION7650 Special Options "E" and "F". 39 March 2008 Add new communications card options to ION7550 RTU (same change as for the ION7550/ION7650). 40 May 2008 Removed CTs, VTs and terminal blocks. Removed ION7700 product line (obsolete). 41 July 2008 Changed description of brand code “M” from “Merlin Gerin” to “Schneider Electric”. 42 September 2008 Removed COM32 and COM128 products. Minor change to the ION8600 C1 communications option description. 43 January 2009 O2 initiative changes (reduced option set for the ION7300 series and ION7550/ION7650). Made the Power Measurement brand obsolete and changed it to Schneider Electric. 44 July 2009 ION Enterprise 5.6 information exchanged for ION Enterpise 6.0. Rev date: January 2009 Page 4 of 23 70052-0188-43 Product Part Number Guide Contents HARDWARE .................................................................................................................................... 7 ION8800 ........................................................................................................................................................ 7 ION8800 Comm & I/O module ................................................................................................................................ 8 ION8800 Related Items .......................................................................................................................................... 8 ION8600 ........................................................................................................................................................ 9 ION8600 I/O Expander* ........................................................................................................................................ 10 ION8600 Related Items* ....................................................................................................................................... 10 ION7650 ...................................................................................................................................................... 11 ION7550 ...................................................................................................................................................... 12 ION7550 RTU.............................................................................................................................................. 13 ION7550 / 7650 Comm Card* ............................................................................................................................... 14 ION7550/7650 Expansion I/O ............................................................................................................................... 14 External I/O Boards and Modules ......................................................................................................................... 14 ION7550 and ION7650 Related Items .................................................................................................................. 14 ION7350 ...................................................................................................................................................... 15 ION7330 ...................................................................................................................................................... 16 ION7300 ...................................................................................................................................................... 17 ION7300 Remote Display ..................................................................................................................................... 18 External I/O Boards and Modules ......................................................................................................................... 18 ION7300 Series Related Items ............................................................................................................................. 18 ION6200 ...................................................................................................................................................... 19 ION6200 Remote Display ..................................................................................................................................... 19 Cable for ION6200 Remote Display...................................................................................................................... 19 ION6200 Stocking Orders ........................................................................................................................... 20 ION6200 Meter Base ............................................................................................................................................ 20 ION6200 Option Card ........................................................................................................................................... 20 ION6200 Power Supply ............................................................................................................................... 20 SOFTWARE................................................................................................................................... 21 PowerLogic ION Enterprise 6.0................................................................................................................... 21 PowerLogic ION Enterprise 6.0 Server Licensing ................................................................................................. 21 PowerLogic ION Enterprise 6.0 Client Licensing .................................................................................................. 21 SQL Server 2005 Products ................................................................................................................................... 21 New Purchases..................................................................................................................................................... 21 Options ................................................................................................................................................................. 21 Upgrades for ION Enterprise ................................................................................................................................ 21 PowerLogic ION Enterprise documentation .......................................................................................................... 21 Appendix A: ION8600 Custom Nameplate ................................................................................. 22 Rev date: January 2009 Page 5 of 23 70052-0188-43 Product Part Number Guide HARDWARE Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION8800. Feature Form Current Voltage Power System Comm Onboard I/O Brand Model Security Set Factor inputs inputs supply Freq module & Comm 8800 0 B ION8800 Brand Model Feature Set Memory / Form Factor Current Inputs Voltage Inputs Power Supply System Frequency Comm Module (field serviceable) Onboard I/O and Comms (not field serviceable, part of base unit) Security Special Order Order Code M P 8800 A B C 1 2 C E 0 B 5 6 Z0 A0 C1 D1 E0 F0 M1 A B C D E 0 1 A C Special Order Description Schneider Electric Branded Schneider Electric Branded ION8800 IEC/DIN 43862 19” rack mount series meter with integrated display, U1-U3 wide-range voltage inputs (57-288 VAC L-N or 99-500 VAC L-L). I1-I3 current inputs with additional I4. Supports ION, Modbus-RTU, DNP 3.0 and DLMS protocols. English and French documentation ships with every meter. For onboard I/O see comments below. Feature Set B + power quality analysis (waveforms and transient capture with 1024 samples/cycle resolution) Feature Set C + EN50160 compliant power quality monitoring Basic Tariff/Energy meter 10 MB logging memory, Essailec connectors 5 MB logging memory, Essailec connectors (I1-I3): Configured for 5A nominal, 10A full scale, 14 Amp fault capture, 0.005A starting current (I1-I3): Configured for 1A nominal, 10A full scale, 14 Amp fault capture, 0.001A starting current (U1-U3): Autoranging (57-288 VAC L-N or 99-500 VAC L-L) Single phase power supply: 85-240 VAC ±10% (47-63 Hz) or 110-270 ±10% VDC Calibrated for 50 Hz systems Calibrated for 60 Hz systems No Comm Module – Meter includes Base Onboard I/O and Comms (see below for details) Std. comms: 1 RS-232/RS-485 port, **1 RS-485 port (COM2) Std. comms AND 10BASE-T Ethernet (RJ-45), 56k universal internal modem (RJ-11) Std. comms AND 10BASE-T Ethernet (RJ-45) / 10BASE-FL Ethernet Fiber, 56k universal internal modem (RJ-11) Std. comms AND 10BASE-T Ethernet (RJ-45) Std. comms AND 10BASE-T Ethernet (RJ-45) / 10BASE-FL (ST fiber optic connection) Std. comms AND 56k universal internal modem (RJ-11) *Base Option AND 8 Form A digital outputs, **1 RS-485 port (COM2) *Base Option AND 8 Form A digital outputs, 3 digital inputs (20-56 VDC/AC) *Base Option AND 8 Form A digital outputs, 3 digital inputs (80-280 VDC/AC) *Base Option AND 1 IRIG-B time sync port, **1 RS-485 port (COM2),3 digital inputs (20-56 VDC/AC) *Base Option AND 1 IRIG-B time sync port, **1 RS-485 port (COM2), 3 digital inputs (80-280 VDC/AC) Password protected, no security lock Password protected with security lock enabled None Tropicalization treatment applied *All Onboard I/O and Comms Base Option includes: 4 Form C solid-state digital outputs, 1 Form C mechanical relay output, one IEC1107 optical communications port, two IEC1107 style optical pulsing ports. **Channel COM2 is available on the port at the back of the meter OR on the Comm Module (if installed). You must select which terminals your communications wiring is connected to during meter setup. Rev date: January 2009 Page 7 of 23 70052-0188-43 Product Part Number Guide Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION8800 Communications module. Comm Module P880C ION8800 Comm & I/O module Comm Module Special Order Type Special Order Order Code 880C A0 C1 D1 E0 F0 M1 A C Description ION8800 Communications module for field retrofit installations Std. comms: 1 RS-232/RS-485 port, **1 RS-485 port (COM2) Std. comms AND 10BASE-T Ethernet (RJ-45), 56k universal internal modem (RJ-11). Std. comms AND 10BASE-T Ethernet (RJ-45) / 10BASE-FL Ethernet Fiber, 56k universal internal modem (RJ-11). Std. comms AND 10BASE-T Ethernet (RJ-45). Std. comms AND 10BASE-T Ethernet (RJ-45) / 10BASE-FL (ST fiber optic connection). Std. comms AND 56k universal internal modem (RJ-11) None Tropicalization treatment applied **Channel COM2 is available on the port at the back of the meter OR on the Comm Module (if installed). You must select which terminals your communications wiring is connected to during meter setup. ION8800 Related Items BATT-REPLACE-8XXX RACK-8800-RAW IEC-OPTICAL-PROBE CD-TECHDOC Rev date: January 2009 Replacement batteries for the ION8600 or ION8800, quantity 10 IEC/DIN 34862 19” Rack with female mating voltage/current and I/O blocks unassembled. IEC 61107 compliant Optical Probe (DB-9) for use with ION8800 meters Compact disc containing the latest version of technical documentation for ION hardware and software products. Page 8 of 23 70052-0188-43 Product Part Number Guide Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION8600. Brand Model Feature set Form Factor Current inputs Voltage inputs Power supply System Freq Comm I/O Security 8600 0 ION8600 Brand Model Feature Set Form Factor Current Inputs Voltage Inputs Power Supply Order Code S P M 8600 A B C 0 1 2 3 N 4 5 6 7 8 9 C E 0 E G System Frequency Communications H J 5 6 A0 C1 C2 E0 F0 M1 Onboard I/O A B Security 0 1 Special Order 3 4 A B K L Special Order Description Square D branded Schneider Electric branded Schneider Electric branded ION8600 Advanced Revenue Meter 10MB memory, 50 data recorders (800 channels), waveform recorders, transient detection, flicker, interharmonics 4MB memory, 20 data recorders (320 channels), MODBUS Mastering, additional serial port 2MB memory, 2 data recorders (32 channels), sag/swell detection * Form 9S Base: 57-277 V (autoranging) 3-Element, 4-Wire Form 35S Base: 120-480 V (autoranging) 2-Element, 3-Wire * Form 36S Base: 57-277 V (autoranging) 2 1/2-Element, 4-Wire * Form 39S with neutral current input (15 Terminal Base): 57-277 V (autoranging) 3-Element, 4-Wire * Form 76S with neutral current input (15 Terminal Base): 57-277 V (autoranging) 2 1/2-Element, 4-Wire Form 9 FT21 Switchboard (meter + case) with break out panel Form 35 FT21 Switchboard (meter + case) with break out panel Form 36 FT21 Switchboard (meter + case) with break out panel Form 9 FT21 Switchboard (meter + case) with break out cable Form 35 FT21 Switchboard (meter + case) with break out cable Form 36 FT21 Switchboard (meter + case) with break out cable 5 Amp nominal, 20 Amp full scale (50 Amp fault capture, start at 0.005A, accurate from 0.05 - 20A RMS) 1 Amp nominal, 10 Amp full scale (24 Amp fault capture, start at 0.001A, accurate from 0.01 - 10A RMS) Standard (see Form Factor above) Form 9S, 36S, 39S, 76S (socket) and Form 9, 36 (FT21 switchboard): 120-277 VAC. Form 35S (socket) and Form 35 (FT21 switchboard): 120-480 VAC. Powered from the meter's voltage connections. Form 9S, 36S (socket) and Form 9, 36 (FT21 switchboard): 57-70 VAC. Powered from the meter's voltage connections. NOT AVAILABLE on Form 35S and Form 35 - you must select the auxiliary power pigtail. Auxiliary Power Pigtail: 65-120 VAC or 80-160 VDC (power from external source) Auxiliary Power Pigtail: 160-277 VAC or 200-350 VDC (power from external source) Calibrated for 50 Hz systems - NOT AVAILABLE with RMICAN or RMICAN-SEAL options Calibrated for 60 Hz systems Infrared port, RS-232/RS-485 port, RS-485 port Infrared Optical port, Ethernet (10BASE-T), 56k universal internal modem (RJ-11), RS-232/485 port, RS-485 port (note the RS-232/485 and RS-485 ports are not available with Feature Set C). Same as C1, but with RJ-31 connector for the modem Infrared Optical port, Ethernet (10BASE-T), RS-232/485 port, RS-485 port (note this port is not available with Feature Set C) Infrared Optical port, Ethernet (10BASE-FL), RS-232/485 port, RS-485 port (note this port is not available with Feature Set C) This option is not available with FT21 switchboard form factors (Form Factor options 4 through 9). This option is not available with the onboard I/O option. Infrared Optical port, 56k universal internal modem (RJ-11), RS-232/485 port, RS-485 port (note this port is not available with Feature Set C) None 4 Form C (KYZ) digital outputs and 3 Form A digital inputs This option is not available with Ethernet Fiber (10BASE-FL) communications option. Password protected, no security lock - NOT AVAILABLE in Canada Password protected with security lock enabled (requires removal of outer cover to configure billing parameters) - NOT AVAILABLE in Canada RMICAN (Measurement Canada approved, security lock enabled) ** RMICAN-SEAL (Measurement Canada approved, factory sealed, and security lock enabled) None IRIG-B GPS time synchronization port *** Customer supplied template (frameworks) installed at the factory *** Customer supplied template (frameworks) and IRIG-B GPS time synchronization port To add custom text to your meter's nameplate label, fill out the ION8600 Custom Nameplate form and submit it with your order. * For Measurement Canada approved meters, allowable voltage input range is 69-277 VAC. ** A filled-out ION8600 RMICAN-SEAL Checklist must accompany each RMICAN-SEAL meter order. *** For Special Order “K” and “L”, you must also order the part number CUST-TEMP-SETUP (see ION8600 Related Items section). When the template (framework) is received, the factory will issue a 5-digit code that will be appended to the ION8600 part number. Rev date: January 2009 Page 9 of 23 70052-0188-43 Product Part Number Guide Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your I/O Expander. Brand I/O Expander I/O Option Cable Length P 850E ION8600 I/O Expander* Brand Digital/Analog I/O Order Code Description P Schneider Electric brand I/O Expander for ION8600 meters: Inputs and Outputs for energy pulsing, control, energy counting, status monitoring, and analog interface to SCADA. I/O Option A External I/O box with 8 digital inputs and 8 digital outputs (4 Form A, 4 Form C) B External I/O box with 8 digital inputs and 4 digital outputs (4 Form C) and 4 analog outputs (0 to 20mA) C External I/O box with 8 digital inputs and 4 digital outputs (4 Form C) and 4 analog outputs (-1mA to 1mA) External I/O box with 8 digital inputs and 4 digital outputs (4 Form C) and 4 analog outputs (two -1 to 1 mA, and D two 0 to 20 mA outputs) Cable Option 0 No cable 5ft extension cable, 24-pin male to 24-pin female Molex connector (do not use on meters with the breakout 1 panel form factor option) 15ft extension cable, 24-pin male to 24-pin female Molex connector (do not use on meters with the breakout 2 panel form factor option) 6ft connector cable, 24-pin male to 14-pin male Molex connector (use only on meters with the breakout panel 3 form factor option) * The I/O Expander is also supported on legacy meters ION8300, ION8400 and ION8500 850E ION8600 Related Items* A-BASE-ADAPTER-9 A-BASE-ADAPTER-35 A-BASE-ADAPTER-39 A-BASE-ADAPTER-76 OPTICAL-PROBE OPTICAL-PROBE-USB Form 9S to Form 9A adapter (http://www.pwrm.com/products/socket_adapters/) Form 35S to Form 35A adapter (http://www.pwrm.com/products/socket_adapters/) Form 39S to Form 39A adapter (http://www.pwrm.com/products/socket_adapters/) Form 76S to Form 76A adapter (http://www.pwrm.com/products/socket_adapters/) Serial Optical Probe (DB-9) via IR port Serial Optical Probe (USB) via IR port. Note: This probe supports all ION meters with ANSI optical ports except ION8600 meters manufactured before November 2006. CBL-8X00BRKOUT 5ft Breakout Cable: 24-pin female Molex connector to one DB9 female connector for RS-232, and 2 sets of twisted pair wires for two RS-485 port connections CBL-8X00IOE5FT 5ft extension cable, mates with 24-pin male Molex connector from the meter to the 24-pin female Molex connector on the I/O Expander box (not for use with breakout panel E8, F8 & G8 form factors) CBL-8X00IOE15FT 15ft extension cable, mates with 24-pin male Molex connector from the meter to the 24-pin female Molex connector on the I/O Expander box (not for use with breakout panel E8, F8 & G8 form factors) CBL-8XX0-BOP-IOBOX 6ft connector cable, 24-pin male to 14-pin male Molex connector for connecting an ION8000 series meter with breakout panel to an I/O Expander Box CUST-TEMP-SETUP Set up (or modification) charge for customer supplied template (framework) at time of shipment BATT-REPLACE-8XXX Replacement batteries for the ION8600, quantity 10 ION-SETUP Configuration software for ION8600 meters. Ships on a CD. CD-TECHDOC Compact disc containing the latest version of technical documentation for ION hardware and software products. * ION8600 related items are also supported on legacy meters ION8300, ION8400 and ION8500 Rev date: January 2009 Page 10 of 23 70052-0188-43 Product Part Number Guide Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7650. Brand Model Form Factor Current inputs Voltage inputs Power supply System Freq Comm I/O Security 7650 0 ION7650 Brand Model Form Factor Current Inputs Order Code S P M 7650 A0 A1 B0 B1 T0 T1 U0 U1 C E F G Voltage Inputs Power Supply System Frequency Communications 0 B C 5 6 A0 C1 D7 E0 F1 M1 I/O Security Special Order A D E H K N P 0 1 3 4 6 A C E F Special Order Description Square D branded Power Measurement branded Schneider Electric branded ION7650: Advanced meter with wide-range voltage inputs (57-347V line-neutral or 100-600V line-line), transient detection, data and waveform recording. Supports ION, Modbus-RTU, and DNP 3.0 protocols. Integrated display with front optical port, 5 MB logging memory, and 512 samples/cycle resolution. Integrated display with front optical port, 5 MB logging memory, and 1024 samples/cycle resolution. Integrated display with front optical port, 10 MB logging memory, and 512 samples/cycle resolution. Integrated display with front optical port, 10 MB logging memory, and 1024 samples/cycle resolution. Transducer (no display) version, with 5 MB logging memory, and 512 samples/cycle resolution. Transducer (no display) version, with 5 MB logging memory, and 1024 samples/cycle resolution. Transducer (no display) version, with 10 MB logging memory, and 512 samples/cycle resolution. Transducer (no display) version, with 10 MB logging memory, and 1024 samples/cycle resolution. 5 Amp nominal, 20 Amp full scale current input 1 Amp nominal, 10 Amp full scale current input Current Probe Inputs (for use with 0-1 VAC current probes; probes sold separately) - NOT AVAILABLE with OFGEM option Current Probe Inputs with three Universal Technic 10A clamp on CTs; meets IEC 1036 accuracy - NOT AVAILABLE with OFGEM option 57 to 347 VAC line-to-neutral / 100 to 600 VAC line-to-line Standard power supply (85-240 VAC, ±10%/47-63 Hz / 110-300 VDC, ±10%) Low voltage DC power supply (20-60 VDC) Calibrated for 50 Hz systems Calibrated for 60 Hz systems. NOT AVAILABLE with OFGEM option Standard communications (1 RS-232/RS-485 port, 1 RS-485 port). Integrated display models also include 1 ANSI Type 2 optical communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45), 56k universal internal modem (RJ-11). Ethernet and modem gateway functions each use a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX Ethernet Fiber, 56k universal internal modem (RJ-11). Ethernet and modem gateway functions each use a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45). Ethernet gateway function uses a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX (SC fiber optic connection). Ethernet gateway function uses a serial communications port. Standard communications plus 56k universal internal modem (RJ-11). Modem gateway function uses a serial communications port. Standard I/O (8 digital inputs, 3 Form C relays, 4 Form A solid-state outputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 mA analog inputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four -1 to 1 mA analog outputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog outputs) Standard I/O plus Expansion I/O card (8 additional Digital In & four 0 to 20 mA analog inputs & four 0 to 20 mA outputs) Standard I/O plus Expansion I/O card (8 additional Digital In & four 0 to 1 Analog Inputs & four -1 to 1 mA analog outputs) Password protected, no hardware lock Password protected and hardware lockable (lock enabled/disabled via jumper on comm card) *RMICAN Measurement Canada approved, security lock enabled *RMICAN-SEAL Measurement Canada approved, factory sealed, security lock enabled Password protected with security lock enabled, terminal cover and UK OFGEM labels None Tropicalization treatment applied EN50160 compliance monitoring and IEC 61000 4-30 Class A measurements, no tropicalization treatment EN50160 compliance monitoring and IEC 61000 4-30 Class A measurements, with tropicalization treatment * RMICAN approval for Delta mode sealing is not yet available. Please contact factory for details. Rev date: January 2009 Page 11 of 23 70052-0188-43 Product Part Number Guide Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7550. Brand Model Form Factor Current inputs Voltage inputs Power supply System Freq Comm I/O Security 7550 0 ION7550 Brand Model Form Factor Current Inputs Order Code S P M 7550 A0 B0 T0 U0 C E F G Voltage Inputs Power Supply System Frequency Communications 0 B C 5 6 A0 C1 D7 E0 F1 M1 I/O A D E H K N P Security Special Order 0 1 3 4 6 A C Special Order Description Square D branded Power Measurement branded Schneider Electric branded ION7550: Advanced meter with wide-range voltage inputs (57-347 line-neutral or 100-600V line-line), sag/swell detection, data and waveform recording, and 256 samples/cycle resolution. Supports ION, Modbus RTU and DNP 3.0 protocols. Integrated display with front optical port and 5 MB logging memory Integrated display with front optical port and 10 MB logging memory. Transducer (no display) version, with 5 MB logging memory. Transducer (no display) version, with 10 MB logging memory. 5 Amp nominal, 20 Amp full scale current input 1 Amp nominal, 10 Amp full scale current input Current Probe Inputs (for use with 0-1 VAC current probes; probes sold separately) - NOT AVAILABLE with OFGEM option Current Probe Inputs with three Universal Technic 10A clamp on CTs; meets IEC 1036 accuracy - NOT AVAILABLE with OFGEM option 57 to 347 VAC line-to-neutral / 100 to 600 VAC line-to-line Standard power supply (85-240 VAC, ±10%/47-63 Hz / 110-300 VDC, ±10%) Low voltage DC power supply (20-60 VDC) Calibrated for 50 Hz systems Calibrated for 60 Hz systems. NOT AVAILABLE with OFGEM option Standard communications (1 RS-232/RS-485 port, 1 RS-485 port). Integrated display models also include 1 ANSI Type 2 optical communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45), 56k universal internal modem (RJ-11). Ethernet and modem gateway functions each use a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX Ethernet Fiber, 56k universal internal modem (RJ-11). Ethernet and modem gateway functions each use a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45). Ethernet gateway function uses a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX (SC fiber optic connection). Ethernet gateway function uses a serial communications port. Standard communications plus 56k universal internal modem (RJ-11). Modem gateway function uses a serial communications port. Standard I/O (8 digital inputs, 3 Form C relays, 4 Form A solid-state outputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 mA analog inputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four -1 to 1 mA analog outputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog outputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs and four 0 to 20 mA outputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 analog inputs & four -1 to 1 mA analog outputs) Password protected, no hardware lock Password protected and hardware lockable (lock enabled/disabled via jumper on comm card) *RMICAN Measurement Canada approved, security lock enabled *RMICAN-SEAL Measurement Canada approved, factory sealed, security lock enabled Password protected with security lock enabled, terminal cover and UK OFGEM labels None Tropicalization treatment applied * RMICAN approval for Delta mode sealing is not yet available. Please contact factory for details. ION7550 / ION7650 Comm Cards, Expansion I/O Cards and related items are listed on pages 14. Rev date: January 2009 Page 12 of 23 70052-0188-43 Product Part Number Guide Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7550 RTU. Brand Model Form Factor RTU Option Power supply Internal Use Comm I/O Security Special Order 7550 N9 9 0 ION7550 RTU Brand Model Form Factor RTU Option Power Supply Internal Use Communications Order Code S P M 7550 A0 B0 T0 U0 N9 B C 9 A0 C1 D7 E0 F1 M1 I/O A D E H K N P Security Special Order Rev date: January 2009 0 A C Description Square D branded Power Measurement branded Schneider Electric branded ION7550 device Integrated display with front optical port and 5 MB logging memory Integrated display with front optical port and 10 MB logging memory. Transducer (no display) version, with 5 MB logging memory. Transducer (no display) version, with 10 MB logging memory. RTU option Standard power supply (85-240 VAC, ±10%/47-63 Hz / 110-300 VDC, ±10%) Low voltage DC power supply (18-75 VDC) This field for internal use only Standard communications (1 RS-232/RS-485 port, 1 RS-485 port). Integrated display models also include 1 ANSI Type 2 optical communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45), 56k universal internal modem (RJ-11). Ethernet and modem gateway functions each use a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX Ethernet Fiber, 56k universal internal modem (RJ-11). Ethernet and modem gateway functions each use a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45). Ethernet gateway function uses a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45) and 100BASE-FX (SC fiber optic connection). Ethernet gateway function uses a serial communications port. Standard communications plus 56k universal internal modem (RJ-11). Modem gateway function uses a serial communications port. Standard I/O (8 digital inputs, 3 Form C relays, 4 Form A solid-state outputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 mA analog inputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four -1 to 1 mA analog outputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog outputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs and four 0 to 20 mA outputs) Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 analog inputs & four -1 to 1 mA analog outputs) Password protected None Tropicalization treatment applied Page 13 of 23 70052-0188-43 Product Part Number Guide Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7550/7650 Comm Card. Comm Card Type Special Order P765C ION7550 / 7650 Comm Card* Order Code Comm Card Type P765C A0 C1 D7 E0 F1 M1 Special Order A C * Firmware v350 or higher required. Description ION7550 / ION7650 Communications card for field retrofit installations Standard communications (1 RS-232/RS-485 port, 1 RS-485 port). Front optical port support for meters with integrated display. Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ-45), 56k universal internal modem (RJ-11; the modem port is shared with the front optical port). Ethernet and modem gateway functions each use a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet, 100BASE-FX Ethernet Fiber, 56k universal internal modem (RJ-11; the modem port is shared with the front optical port). Ethernet and modem gateway functions each use a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet. Ethernet gateway function uses a serial communications port. Standard communications plus 10BASE-T/100BASE-TX Ethernet, 100BASE-FX Ethernet Fiber (SC fiber optic connection). Ethernet gateway function uses a serial communications port. Standard communications plus 56k universal internal modem (RJ-11; the modem port is shared with the front optical port). Modem gateway function uses a serial communications port. None Tropicalization treatment applied Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7550/7650 I/O Card. Expansion I/O Type Special Order P760A ION7550/7650 Expansion I/O Order Code Description I/O Card Type P760A D E H K N P A C ION7550 / ION7650 Expansion I/O card for field retrofit installations Expansion I/O card with eight digital inputs, four 0 to 1 mA analog inputs Expansion I/O card with eight digital inputs, four 0 to 20 mA analog inputs Expansion I/O card with eight digital inputs, four -1 to 1 mA analog outputs Expansion I/O card with eight digital inputs, four 0 to 20 mA analog outputs Expansion I/O card with eight digital inputs, four 0 to 20 mA analog inputs & four 0 to 20 mA outputs Expansion I/O card with eight digital inputs, four 0 to 1 analog inputs and four -1 to 1 mA analog outputs None Tropicalization treatment applied Special Order External I/O Boards and Modules Compatible I/O boards and modules can be ordered from the Grayhill website. To find a distributor, visit http://grayhill.com/wherebuy/where-to-buy.html ION7550 and ION7650 Related Items ADPT-37XX-7500 TERMCVR-7500 M1UB10A1V-10A P32UEP813-1000A P32UEP815-3000A SCT0750-005-5A SCT1250-300-300A CD-TECHDOC Rev date: January 2009 Adapter plate enabling the 7550 or 7650 to fit into a 3710 or 3720 ACM panel cutout Terminal strip cover for the 7550 or 7650 10 A / 1 VAC Universal Technic Clamp On Current Probe 1000 A / 1 VAC Universal Technic Clamp On Current Probe 3000 A / 1 VAC Universal Technic Clamp On Current Probe 5 A / 0.333 VAC Magnelabs Split Core Current Probe 300 A / 0.333 VAC Magnelabs Split Core Current Probe Compact disc containing the latest version of technical documentation for ION hardware and software products. Page 14 of 23 70052-0188-43 Product Part Number Guide Brand Model 7350 ION7350 Brand Model Form Factor Form Factor Order Code S P M 7350 A0 R0 R1 T0 T1 Current Inputs Voltage Inputs Power Supply System Frequency Communications B 0 B C 0 A0 C1 E0 I/O M1 A M N Security Special Order Rev date: January 2009 0 2 6 A B C D Current inputs Voltage inputs Power supply B 0 System Freq 0 Comm I/O Security Special Order Description Square D branded Power Measurement branded Schneider Electric branded ION7350: Advanced power meter with basic sag/swell detection, waveform recording, harmonics (up to the 31st), high-speed data logging and automatic modem dial-out, multiport communications, 4 digital inputs and 4 digital outputs. Integrated display, with front optical port Transducer with RMD (remote display), with front optical port. DOES NOT support Analog Input and/or Analog Output options. Same as R0, but with DIN rail mounts on the transducer. DOES NOT support Analog Input and/or Analog Output options. Transducer (no display). Note you cannot use an RMD on this meter if you order the Analog Input and/or Analog Output options. Transducer (no display) with DIN rail mount. Note you cannot use an RMD on this meter if you order the Analog Input and/or Analog Output options. 5 Amp nominal, 10 Amp full scale current input Autoranging (50 to 347 VAC +25%) P240 power supply (95-240VAC/47-440Hz/120-310 VDC) P24 power supply (20 to 65 VDC) Autoranging (50 and 60 Hz) Two RS-485 ports. One RS-485 EtherGate port, one RS-485 ModemGate port, 10BASE-T Ethernet (RJ-45), 33.6k universal internal modem (RJ-11). DOES NOT support Analog Input and/or Analog Output options. One 10BASE-T Ethernet (RJ-45) port, one RS-485 port, one RS-485 EtherGate port.. DOES NOT support Analog Input and/or Analog Output options. One 33.6k universal internal modem (RJ-11) port, one RS-485 port, one RS-485 ModemGate port. No analog inputs/outputs. You must choose this option if ordering RMD remote display option (Form Factor type "R1") or Ethernet port options (Communications types "C1" or "E0"). Four 0 to 1 mA analog inputs & four 0 to 1 mA analog outputs. NOT AVAILABLE with RMD or Ethernet options Four 0 to 20 mA analog inputs & four 0 to 20 mA analog outputs. NOT AVAILABLE with RMD or Ethernet options Password protected, no hardware lock Password protected with hardware lock enabled Password protected with security lock enabled, terminal cover and UK OFGEM labels None Pre-set to MODBUS (available for Form Factor T0 and T1 only) Tropicalization treatment applied Tropicalization treatment applied and pre-set to MODBUS (available for Form Factor T0 and T1 only) Page 15 of 23 70052-0188-43 Product Part Number Guide Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7330. Brand Model Form Factor Current inputs Voltage inputs Power supply System Freq Comm I/O Security 7330 B 0 0 ION7330 Brand Model Form Factor Order Code S P M 7330 A0 R0 R1 T0 T1 Current Inputs Voltage Inputs Power Supply System Frequency Communications B 0 B C 0 A0 C1 E0 I/O M1 A M N Security Special Order 0 2 3 4 6 A B C D Special Order Description Square D branded Power Measurement branded Schneider Electric branded ION7330: Advanced power meter with over 200 high accuracy, 3-phase measurements, data logging, multiport communications, 4 digital inputs and 4 outputs. Integrated display, with front optical port Transducer with RMD (remote display), with front optical port. DOES NOT support Analog Input and/or Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL. Same as R0, but with DIN rail mounts on the transducer. DOES NOT support Analog Input and/or Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL. Transducer (no display). Note you cannot use an RMD on this meter if you order the Analog Input and/or Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL. Transducer (no display) with DIN rail mount. Note you cannot use an RMD on this meter if you order the Analog Input and/or Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL. 5 Amp nominal, 10 Amp full scale current input Autoranging (50 to 347 VAC +25%) P240 power supply (95-240VAC/47-440Hz/120-310 VDC) P24 power supply (20 to 65 VDC) Autoranging (50 and 60 Hz) Two RS-485 ports. One RS-485 EtherGate port, one RS-485 ModemGate port, 10BASE-T Ethernet (RJ-45), 33.6k universal internal modem (RJ-11). DOES NOT support Analog Input and/or Analog Output options. One 10BASE-T Ethernet (RJ-45) port, one RS-485 port, one RS-485 EtherGate port.. DOES NOT support Analog Input and/or Analog Output options. One 33.6k universal internal modem (RJ-11) port, one RS-485 port, one RS-485 ModemGate port. No analog inputs/outputs. You must choose this option if ordering RMD remote display option (Form Factor type “R0” or "R1") or Ethernet port options (Communications types "C1" or "E0"). Four 0 to 1 mA analog inputs & four 0 to 1 mA analog outputs. NOT AVAILABLE with RMD or Ethernet options Four 0 to 20 mA analog inputs & four 0 to 20 mA analog outputs. NOT AVAILABLE with RMD or Ethernet options Password protected, no hardware lock Password protected with hardware lock enabled RMICAN Measurement Canada approved **RMICAN-SEAL Measurement Canada approved, factory sealed Password protected with security lock enabled, terminal cover and UK OFGEM labels None Pre-set to MODBUS (available for Form Factor T0 and T1 only). Not available with Security options RMICAN or RMICAN-SEAL. Tropicalization treatment applied Tropicalization treatment applied and pre-set to MODBUS (available for Form Factor T0 and T1 only). Not available with Security options RMICAN or RMICAN-SEAL. ** A filled-out ION7300 Series RMICAN-SEAL Checklist must accompany each RMICAN-SEAL meter order. Rev date: January 2009 Page 16 of 23 70052-0188-43 Product Part Number Guide Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7300. Brand Model Form Factor Current inputs Voltage inputs Power supply System Freq Comm I/O Security 7300 B 0 0 ION7300 Brand Model Form Factor Order Code S P M 7300 A0 R0 R1 T0 T1 Current Inputs Voltage Inputs Power Supply System Frequency Communications I/O B 0 B C 0 A0 E0 P0 A M N Security Special Order 0 2 3 4 6 A B C D Special Order Description Square D branded Power Measurement branded Schneider Electric branded ION7300: Advanced power meter with over 100 high accuracy, 3-phase measurements, 1 RS-485 communication port and 4 digital outputs. Supports ION and Modbus-RTU protocols. Integrated display, with front optical port Transducer with RMD (remote display), with front optical port. DOES NOT support Analog Input and/or Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL. Same as R0, but with DIN rail mounts on the transducer. DOES NOT support Analog Input and/or Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL. Transducer (no display). Note you cannot use an RMD on this meter if you order the Analog Input and/or Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL. Transducer (no display) with DIN rail mount. Note you cannot use an RMD on this meter if you order the Analog Input and/or Analog Output options. Not available with Security options RMICAN or RMICAN-SEAL. 5 Amp nominal, 10 Amp full scale current input Autoranging (50 to 347 VAC +25%) P240 power supply (95-240VAC/47-440Hz/120-310 VDC) P24 power supply (20 to 65 VDC) Autoranging (50 and 60 Hz) One RS 485 port One RS 485 port, one 10BASE-T Ethernet (RJ-45) One RS 485 port, one Profibus communications. Available only on Integrated Display model (form factor “A0”). No analog inputs/outputs. You must choose this option if ordering RMD remote display options (Form Factor type "R0" or “R1”), or Ethernet or Profibus port options (Communications options "E0" or “P0”). Four 0 to 1 mA analog inputs & four 0 to 1 mA analog outputs. NOT AVAILABLE with RMD or Ethernet options Four 0 to 20 mA analog inputs & four 0 to 20 mA analog outputs. NOT AVAILABLE with RMD or Ethernet options Password protected, no hardware lock Password protected with hardware lock enabled RMICAN Measurement Canada approved **RMICAN-SEAL Measurement Canada approved, factory sealed Password protected with security lock enabled, terminal cover and UK OFGEM labels None Pre-set to MODBUS (available for Form Factor T0 and T1 only). Not available with Security options RMICAN or RMICAN-SEAL. Tropicalization treatment applied Tropicalization treatment applied and pre-set to MODBUS (available for Form Factor T0 and T1 only). Not available with Security options RMICAN or RMICAN-SEAL. ** A filled-out ION7300 Series RMICAN-SEAL Checklist must accompany each RMICAN-SEAL meter order. Rev date: January 2009 Page 17 of 23 70052-0188-43 Product Part Number Guide Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION7300/ION7330/ION7350 Remote Modular Display. Brand Display Type ION7300 Remote Display Order Code Description Brand S Square D branded P Power Measurement branded M Schneider Electric branded Display Type* RMD-7300 ION7300 Remote Modular Display with 6 ft. DB25 cable RMD-7330 ION7330 Remote Modular Display with 6 ft. DB25 cable RMD-7350 ION7350 Remote Modular Display with 6 ft. DB25 cable * Remote Modular Display cannot be used with TRAN units that contain an analog I/O card External I/O Boards and Modules Compatible I/O boards and modules can be ordered from the Grayhill website. To find a distributor, visit http://grayhill.com/wherebuy/where-to-buy.html ION7300 Series Related Items GSKT OPTICAL-PROBE OPTICAL-PROBE-USB ADPT-37XX-73XX RAP ACCUREPORT TERMCVR-73XX CD-TECHDOC Rev date: January 2009 Water resistant gasket Serial Optical Probe (DB-9) via IR port Serial Optical Probe (USB ) via IR port Adapter plate enabling an ION73xx to fit a 3710/3720 panel cutout Adapter plate to mount an ION73xx in an ANSI C39.1 (round hole) cutout Factory generated accuracy graph Terminal strip cover Compact disc containing the latest version of technical documentation for ION hardware and software products. 62H Page 18 of 23 70052-0188-43 Product Part Number Guide Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION6200. Brand Model Form Factor Current inputs Voltage inputs Power supply System Freq Comm I/O Security 6200 A 0 0 Order Code ION6200 Brand Model Form Factor S P M 6200 A0 R1 R2 R3 T1 M0 N1 N2 N3 Current Inputs Voltage Inputs Power Supply System Frequency Communications I/O Security Measurement Package A 0 B C D 0 Z0 A0 A B 0 2 3 4 N P R Measurements Description Square D branded Schneider Electric branded Schneider Electric branded ION6200 Meter Kit: ION6200 Meter base, Options Card and Power Supply. Integrated display model Transducer model with DIN rail mount, Remote Display and 14-ft cable (RJ-11, 6 conductor, 26 gauge). Transducer model with DIN rail mount, Remote Display and 6-ft cable (RJ-11, 6 conductor, 26 gauge). Transducer model DIN rail mount, Remote Display and 30-ft cable (RJ-11, 6 conductor, 26 gauge). Transducer model with DIN rail mount (requires Comms or pulse outputs) MegaWatt option on Integrated Display model. Not available with Security options RMICAN or RMICAN-SEAL. MegaWatt option on Transducer model with DIN rail mount, Remote Display and 14-ft cable (RJ-11, 6 conductor, 26 gauge). Not available with Security options RMICAN or RMICAN-SEAL. MegaWatt option on Transducer model with DIN rail mount, Remote Display and 6-ft cable (RJ-11, 6 conductor, 26 gauge). Not available with Security options RMICAN or RMICAN-SEAL. MegaWatt option on Transducer model with DIN rail mount, Remote Display and 30-ft cable (RJ-11, 6 conductor, 26 gauge). Not available with Security options RMICAN or RMICAN-SEAL. 10 Amp current inputs (12 Amp max) Autoranging (57-400 VAC L-N / 99-690 VAC L-L) P620PB: Standard Plug-in Power Supply (100-240 VAC / 50-60 Hz or 110-300 VDC) P620PC: Low voltage DC Plug-in Power Supply (20-60 VDC) P620PD: 480 V power supply (480 VAC, 60Hz) Calibrated for use with 50 Hz or 60 Hz systems No communications Single RS-485 port (supports Modbus RTU protocol and ION-compatible PML protocol) No I/O This option activates the two Form A digital outputs for kWh, kVARh or kVARh energy pulsing No hardware lock (setup is password protected) RMANSI: Revenue Meter approved for use in the United States (ANSI C12.16 approved; meets ANSI C12.20 class 0.5 accuracy at 23°C; 10A current inputs only) RMICAN: Measurement Canada approved revenue meter for use in Canada (10A current inputs only) **RMICAN-SEAL: Factory-sealed and Measurement Canada approved revenue meter Standard Measurements (Volts/Amps per phase and avg) Enhanced Package #1 (Standard Measurements plus Energy/Power total, Frequency, Power Factor total, Neutral Current Enhanced Package #2 (all measurements) ** A filled-out ION6200 RMICAN-SEAL Checklist must accompany each RMICAN-SEAL meter order. Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION6200 Remote Display. Brand Model Display Type Cable Length 620D ION6200 Remote Display Brand Model Display Type Cable Length Order Code S P M 620D R N 0 1 Description Square D branded Schneider Electric branded Schneider Electric branded Remote Display Unit for the ION6200 Transducer meter base Standard display MegaWatt option — for use with Transducer meter base with MegaWatt option. - NOT AVAILABLE for RMICAN or RMICAN-SEAL meters No cable 14-ft cable for connecting Remote Display Unit to the ION6200 Transducer meter base. Cable for ION6200 Remote Display P620C1 P620C2 P620C3 Rev date: January 2009 14-ft cable for connecting Remote Display Unit to the ION6200 Transducer meter base. 6-ft cable for connecting Remote Display Unit to the ION6200 Transducer meter base. 30-ft cable for connecting Remote Display Unit to the ION6200 Transducer meter base. Page 19 of 23 70052-0188-43 Product Part Number Guide ION6200 Stocking Orders The ION6200 is made up of three separate components: the Meter Base, Option Card and Power Supply. Each of these components are required to create one complete ION6200. The following order scheme is intended for customers who purchase for stocking purposes. For stocking orders, customers have the option of purchasing quantities of the separate components (i.e. meter base, option card & power supply) and then mixing and matching them as required to serve their needs. Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION6200 Meter Base. Brand Model Form Factor Current inputs Voltage inputs System Freq 620B A 0 0 ION6200 Meter Base Order Code Brand S P M Model Form Factor 620B A0 M0 T1 Current Inputs Voltage Inputs System Freq A 0 0 Description Square D branded Schneider Electric branded Schneider Electric branded ION6200 meter base Integrated Display on meter base MegaWatt option on meter base with Integrated Display - NOT AVAILABLE for RMICAN or RMICAN-SEAL meters Transducer meter base with DIN rail mounts - NOT AVAILABLE for RMICAN or RMICAN-SEAL meters 10 Amp current inputs (12 Amp max) Auto-ranging (57-400 VAC L-N / 99-690 VAC L-L) Calibrated for use with 50 Hz or 60 Hz systems Select one code from each ordering category and fill in the boxes below. Use this group of codes when you order your ION6200 Option Card. Model Comm I/O Security Measurements P620K ION6200 Option Card Order Code Model Communications P620K Z0 A0 A B 0 2 I/O Security 3 4 N P Measurement Options R Description Option Card to activate basic and advanced features on the ION6200. No communications Single RS-485 port (supports Modbus RTU protocol and PML protocol) No I/O This option activates the two Form A digital outputs for kWh, kVARh or kVARh energy pulsing No hardware lock (setup is password protected) RMANSI: Revenue Meter approved for use in the United States (ANSI C12.16 approved; meets ANSI C12.20 class 0.5 accuracy at 23°C; 10A current inputs only) RMICAN: Measurement Canada approved revenue meter for use in Canada (10A current inputs only) RMICAN-SEAL: Factory-sealed and Measurement Canada approved revenue meter Standard Measurements (Volts/Amps per phase and avg) Enhanced Package #1 (Standard Measurements plus Energy/Power total, Frequency, Power Factor total, Neutral Current) Enhanced Package #2 (all measurements) ION6200 Power Supply P620PB P620PC P620PD Rev date: January 2009 Standard Plug-in Power Supply (100-240 VAC / 50-60 Hz or 110-300 VDC) for the ION6200. Low voltage DC Plug-in Power Supply (20-60 VDC) for the ION6200. 480V power supply (480VAC, 60Hz) for the ION6200. Page 20 of 23 70052-0188-43 Product Part Number Guide SOFTWARE PowerLogic ION Enterprise 6.0 PowerLogic ION Enterprise 6.0 Server Licensing Every new system must be ordered with one (1) IONE60-BASE software and a minimum of five (5) IONE60-DL device licences. The IONE60-BASE software includes all PowerLogic ION Enterprise applications (Communications, database components, Vista, Reporter, WebReach, Virtual Processor, OPC Client), for installation and use on a single PC (server or workstation). Beyond the first 5 devices, the customer has the ability to order the exact number of devices required for the system. As the customer adds devices, additional device licences can be ordered (minimum 5 devices). PowerLogic ION Enterprise 6.0 Client Licensing A client licence is required for all PCs running PowerLogic ION Enterprise applications (e.g. Vista, Reporter, Management Console, or any combination of these), or PCs that use Terminal Services or Remote Desktop to access the ION Enterprise Server. Previous licences are non-transferable. SQL Server 2005 Products We now have the option to bundle Microsoft SQL Server 2005 in conjunction with ION software. The IONE-SQL-2005 product is a 1 CPU licence for SQL Server 2005 Standard Edition. For each additional CPU used by SQL Server, an additional IONE-SQL-2005-CPU is required. These products are for use only with licensed copies of ION Enterprise or ION EEM. New Purchases IE60-BASE-ENG PowerLogic ION Enterprise base software (English, DVD) IE60-DL-S(1) Individual Device Licence for High-End Devices, compatible with all supported device types IE60-DL-M (1) Individual Device Licence for Mid-Range Devices, compatible with all supported device types IE60-DL-E (1) Individual Device Licence for Entry-Range Devices, compatible with Entry-Range devices IE60-CL(2) PowerLogic ION Enterprise Client Licence Options IONE-SQL-2005 Integrated SQL Server 2005 Standard Edition (for use with ION Enterprise only) – Processor Licence for 1 CPU IONE-SQL-2005-CPU Additional CPU Licence for Integrated SQL Server 2005 IONE-OPC-V1 OPC Server support for ION Enterprise IONE-PQDIF-V1 PQDIF Exporter Module for ION Enterprise Upgrades for ION Enterprise1 IE60-BASE-ENG-UPG PowerLogic ION Enterprise base software (English, DVD) - upgrade from v5.5 SP2 or later IE60-DL-S-UPG Individual Device Licence Upgrade for High-End Devices, compatible with all supported device types IE60-DL-M-UPG Individual Device Licence Upgrade for Mid-Range Devices, compatible Mid- and Entry-Range devices IE60-DL-E-UPG Individual Device Licence Upgrade for Entry-Range Devices, compatible with Entry-Range devices IE60-CL-UPG PowerLogic ION Enterprise Client Licence - upgrade 1 Upgrades only apply to ION Enterprise 5.5/5.6 PowerLogic ION Enterprise documentation CD-TECHDOC Compact disc containing the latest version of technical documentation for ION hardware and software products. (1) An appropriate device licence (IE60-DL-S, DL-M, or DL-E) is required for each meter or device connected to your PowerLogic ION Enterprise system. Device licences have a minimum order quantity of ten (10). (2) A client licence is required for each workstation that is used to connect to your primary PowerLogic ION Enterprise server. * Please refer to Schneider Electric sales representative for full pricing and part numbers information. Rev date: January 2009 Page 21 of 23 70052-0188-43 Product Part Number Guide Appendix A: ION8600 Custom Nameplate If you would like to add custom text to your meter's nameplate label, fill out this form and submit it with your P.O. Customer: P.O.#: P.O. line#: Quantity: Mult by FM 35S V~ 120 -480 W 3WD M8G12345678900000 PQ-9903A000-00 DEMAND RESET 17 characters maximum *Meter Tag Number (required): Bar Code 39: 17 characters maximum Bar Code Interpretation Line: PQ9903A000-00 Buyer Specified (Positions 13 to 17) Manufacturer Data Code (Position 3) Meter Specification Data Code (Position 1 & 2) ZY Form 9S 0.0V TA2.5 M8 Form 35S 0.0V TA2.5 M9 Form 36S 0.0V TA2.5 2C Form 39S 0.0V TA2.5 2D Form 76S 0.0V TA2.5 Manufacturer Serial Number (positions 4 to 12) These fields are set to the Manufacturer’s serial number unless specified by the customer. Kt: 0.0 Kt: 0.0 Kt: 0.0 Kt: 0.0 Kt: 0.0 3Ф4W 3Ф3W 3Ф4W 3Ф4W 3Ф4W 3EL 2EL 2½EL 3EL 2½EL *The METER TAG number is a mandatory requirement for this checklist; each meter to be sealed must have a unique tag number. Notes: Rev date: January 2009 Page 22 of 23 70052-0188-43