L1O WINDOWS/ ROOFLIGHTS/ SCREENS/ LOUVRES MODEL SPECIFICATION PROJECT : PREPARED FOR : PACKAGE : Glazing APPLICATION : Windows / Facades CLAUSE NUMBER: To be read with Preliminaries! General conditions. GENERAL INFORMATION! REQUIREMENTS 110 EVIDENCE OF PERFORMANCE o o o o o o o Certification: Provide independently certified evidence that all incorporated components comply with specified performance requirements. CE Marking: All products to carry the CE mark and to have passed The Construction Products Directive: 89/106/EEC. Product Standard DS/EN 14351-1:2006. Secured By design; Manufacturer must be a member of the Secured By Design Scheme and offer the following Secured by Design approved configurations; Fixed unit, Top hung projecting, Side hung and Terrace door. Check http://www.securedbydesign.com/companies/index.aspx Warranty. Manufacturer to issue a written 10 year warranty on the composite windows and composite doors. Foamed timber plate doors and heavy duty aluminium doors to carry a 5 year warranty period. All electrical equipment to carry a warranty of 1 year. Manufacturer must also be able to offer (at extra over cost) an optional extended product warranty on the composite windows and doors for up to 15 years. COMPONENTS: 1 400 COMPOSITE ALUMINIUM / TIMBER WINDOWS o o o o o o o o o Manufacturer: PRO TEC Windows Ltd, The Plough Barn, Feltimores Park, Chalk lane, Moor Hall Road, Harlow, Essex. CM17 0PF Tel 01279 424046, Fax 01279 421709, Web. www.protecwindows.com Product reference: PRO TEC Classic System Type: Windows and doors to be of a true composite construction which does not allow for any timber component to fall within the wet-zone of the units. Aluminium clad timber construction is not acceptable. All elements to be thermally-broken, dual-sealed to provide an average overall U Value of no more than 1.56 W/m2K Glazing rebate: To suit a 28mm glazing unit with the ability to fit a glazing unit up to 36mm on opening lights and maximum of 42mm on fixed lights. Profile: Standard 54mm x 60 sash, 42mm x 116mm frame, 58mm x 116mm transom and mullion. Where required overall internal timber profile depth, must be able to range from 116mm to 250mm. When joining multiple elements, the system must have option to maintain a 58mm transom and mullion section, via use of 16/42 combination of timber profile. Generally: PRO TEC Classic side hung, top hung, tilt & turn, fully reversible, sliding and fixed lights. Butt hinges / friction stays, where required (refer to architects drawings). For full details of individual windows refer to quotation ref: ……………………… -Performance: o Inward Opening: Air Permeability according Classification Class 4 Water tightness according Classification E1500 o Outward Opening: Air Permeability according Classification Class 4 Water tightness according Classification E1600 ……………………… -Materials: 2 to EN 1026:2000 – EN 12207:2000 to EN 1027:2000 – EN 12208:2000 to EN 1026:2000 – EN 12207:2000 to EN 1027:2000 – EN 12208:2000 o o o o Exterior frame: Extruded aluminium alloy profiles, must be manufactured in the alloy ALMg SI 0.5 in accordance with DIN 17615 Finish: Factory applied polyester powder coating to the standard RAL colours by Azko Nobel to a gloss level of 85% RAL Colour: …………………………. Interior frame: North Scandinavian Pine from sustainably-managed source, PEFC certification to be provided. Timber to be finger jointed and or laminated as required, clear, stained or painted finish to be applied as per the architect’s specification. Finish: Factory applied clear lacquer or water-based acryl/alkyd paint to an approved RAL colour. Colours to a gloss level of 25%. -Glazing Details: o o o o o o o o Double glazed sealed units to give overall maximum average U value of 1.1W/m2K. Triple glazed sealed units to give overall maximum average U value of 0.9W/m2K U values: To meet the target emissions rate in Building Regulations Approved Document L: 2006, manufacture to have allowed for windows to be glazed with double glazed units incorporating low emissivity coated glass and an argon gas filling within the glazing cavity. When glazed with standard 4-20-4 insulated units PRO TEC Classic window system will achieve an overall U-value of 1.56 W/m2k when calculated in accordance with BS EN ISO 10077: Part 1: 2006. The window size used for this calculation is 1230mm x 1480mm as specified in BS EN ISO 12567: Part 1: 2000. Glass to glass corners must be stepped glazing, which provide a very slim corner joint. Acoustic Rating: As required windows to be glazed with 28mm sealed units comprising 4mm clear outer/20mm argon cavity/4mm clear super low-e inner to provide a minimum Rw rating of 31dB when tested in accordance with ISO 140-3:95 “Acoustics – Measurement of sound insulation in buildings and of building elements – Part 3: Laboratory measurement of airborne sound insulation of building elements” at a size of 1185 x 1185mm, Manufacturer to provide report of the individual frequency ratings for approval. Glass thickness and type to suit application. Laminated / toughened to BS6206 & BS6262 where applicable Manufacturer as per architect’s specification. -Ironmongery / Accessories: o Side and top hung projecting sashes to be fitted with a key locking espagnolette handle and a non-locking restrictor. o Fully reversible sashes to be fitted with a key locking espagnolette handle and an integral hinge restrictor. o Turn tilt / tilt slide / sliding sashes to be fitted with a key locking espagnolette handle. o Terrace doors opening out to be fitted with a key locking espagnolette handle which operates a brake on the head. o The window ironmongery to be generally manufactured from zinc chromated steel with a matt chrome finish. o Locking espagnolette brushed chromium plated (by FIX) 3 o Titon Trimvent 90 if required to be surface mounted on the timber framing profiles as indicated on the enclosed specification schedules. Each trickle ventilator to provide an “Equivalent Area” of 2510mm2 in accordance with EN 13141: Part 1: 2004 as required to be measured by Building Regulations Approved Document F: 2006. Should a measurement of ‘Free Area’ be applicable to your project, each ventilator will provide 4000mm2. Delete and replace with: Free Area of trickle ventilators to provide 4000 mm2 per ventilator. The system to have the ability to provide the option for Acoustic trickle vents as per the architects drawings. -Fixing: o To manufacturers recommendations by approved PRO TEC Installer INSTALLATION o All PRO TEC windows and doors are to be installed vertically into prepared openings. All PRO TEC products are internally glazed except fixed lights which are externally glazed. o Suitable fixing grounds or interface materials to be provided by others which are immediately adjacent to the product and allow point loads to be used at centres in accordance with the standard fixing positions. Window and door elements are not to be utilised as structural elements and no loads shall be imposed upon them other than which they are expressly designed for. Their own dead weight and the wind loads acting upon them (both individual and collective frames) require to be transferred back to the grounds or interface materials to which they are fixed. Should the grounds be inadequate to take such point loads to comply with BS 6399 Part 2, reinforced fixing brackets, a change in substrate materials or re-design may be required, this to be confirmed during manufacturing design stage and in conjunction with the approved installer. o o 710 PROTECTION COMPONENTS o 4 General: Components should not be delivered to site unless they can be installed immediately or placed on an even support, away from damp and dirt. Units not installed immediately must be protected from weather and site contamination. o Stored components should be stacked vertically or near vertically on level bearers, separated with spacers to prevent damage by and to projecting ironmongery, beads, etc. 765 WINDOW INSTALLATION GENERALLY o o o o Installation: Into prepared openings. Gap between frame edge and surrounding construction: Nominal 10 mm. Where a cill pressing is to be installed allow 25mm Installation before render No requirements for render trims Distortion: Install windows without twist or diagonal racking. 770 DAMP PROOF COURSES IN PREPARED OPENINGS o Location: Ensure correct positioning in relation to window frames. Do not displace during fixing operations. 784 FIXING OF COMPOSITE FRAMES o Standard: As section Z20. Fasteners: _______ - Spacing: When not predrilled or specified otherwise, position fasteners not more than 150 mm from ends of each jamb, adjacent to each hanging point of opening lights, and at maximum 500 mm centres. 810 SEALANT JOINTS o o o 5 Sealant: Manufacturer: Arbosil or similar Product reference: 1096 silicone sealant or similar Colour: TBC Application: As section Z22 to prepared joints. Finish triangular fillets to a flat or slightly convex profile. Alternative material, Illmod 600 pre-compressed expanding tape or an equal or approved tape.