o Manufacturer to provide report of the individual

advertisement
L1O WINDOWS/ ROOFLIGHTS/ SCREENS/ LOUVRES
MODEL SPECIFICATION
PROJECT
:
PREPARED FOR :
PACKAGE
: Glazing
APPLICATION
: Windows / Facades
CLAUSE NUMBER:
To be read with Preliminaries! General conditions.
GENERAL INFORMATION! REQUIREMENTS
110 EVIDENCE OF PERFORMANCE
o
o
o
o
o
o
o
Certification: Provide independently certified evidence that all
incorporated components comply with specified performance
requirements.
CE Marking: All products to carry the CE mark and to have passed
The Construction Products Directive: 89/106/EEC. Product Standard
DS/EN 14351-1:2006.
Secured By design; Manufacturer must be a member of the
Secured By Design Scheme and offer the following Secured by
Design approved configurations; Fixed unit, Top hung projecting,
Side hung and Terrace door.
Check http://www.securedbydesign.com/companies/index.aspx
Warranty. Manufacturer to issue a written 10 year warranty on the
composite windows and composite doors.
Foamed timber plate doors and heavy duty aluminium doors to
carry a 5 year warranty period.
All electrical equipment to carry a warranty of 1 year.
Manufacturer must also be able to offer (at extra over cost) an
optional extended product warranty on the composite windows and
doors for up to 15 years.
COMPONENTS:
1
400 COMPOSITE ALUMINIUM / TIMBER WINDOWS
o
o
o
o
o
o
o
o
o
Manufacturer: PRO TEC Windows Ltd, The Plough Barn, Feltimores
Park, Chalk lane, Moor Hall Road, Harlow, Essex. CM17 0PF
Tel 01279 424046, Fax 01279 421709, Web.
www.protecwindows.com
Product reference: PRO TEC Classic System
Type: Windows and doors to be of a true composite construction
which does not allow for any timber component to fall within the
wet-zone of the units. Aluminium clad timber construction is not
acceptable. All elements to be thermally-broken, dual-sealed to
provide an average overall U Value of no more than 1.56 W/m2K
Glazing rebate: To suit a 28mm glazing unit with the ability to fit a
glazing unit up to 36mm on opening lights and maximum of 42mm
on fixed lights.
Profile: Standard 54mm x 60 sash, 42mm x 116mm frame, 58mm
x 116mm transom and mullion. Where required overall internal
timber profile depth, must be able to range from 116mm to
250mm.
When joining multiple elements, the system must have option to
maintain a 58mm transom and mullion section, via use of 16/42
combination of timber profile.
Generally: PRO TEC Classic side hung, top hung, tilt & turn, fully
reversible, sliding and fixed lights. Butt hinges / friction stays,
where required (refer to architects drawings).
For full details of individual windows refer to quotation ref:
………………………
-Performance:
o Inward Opening:
Air Permeability according
Classification Class 4
Water tightness according
Classification E1500
o Outward Opening:
Air Permeability according
Classification Class 4
Water tightness according
Classification E1600
………………………
-Materials:
2
to EN 1026:2000 – EN 12207:2000
to EN 1027:2000 – EN 12208:2000
to EN 1026:2000 – EN 12207:2000
to EN 1027:2000 – EN 12208:2000
o
o
o
o
Exterior frame: Extruded aluminium alloy profiles, must be
manufactured in the alloy ALMg SI 0.5 in accordance with DIN
17615
Finish: Factory applied polyester powder coating to the standard
RAL colours by Azko Nobel to a gloss level of 85% RAL Colour:
………………………….
Interior frame: North Scandinavian Pine from sustainably-managed
source, PEFC certification to be provided. Timber to be finger
jointed and or laminated as required, clear, stained or painted
finish to be applied as per the architect’s specification.
Finish: Factory applied clear lacquer or water-based acryl/alkyd
paint to an approved RAL colour. Colours to a gloss level of 25%.
-Glazing Details:
o
o
o
o
o
o
o
o
Double glazed sealed units to give overall maximum average U
value of 1.1W/m2K. Triple glazed sealed units to give overall
maximum average U value of 0.9W/m2K
U values: To meet the target emissions rate in Building Regulations
Approved Document L: 2006, manufacture to have allowed for
windows to be glazed with double glazed units incorporating low
emissivity coated glass and an argon gas filling within the glazing
cavity.
When glazed with standard 4-20-4 insulated units PRO TEC Classic
window system will achieve an overall U-value of 1.56 W/m2k when
calculated in accordance with BS EN ISO 10077: Part 1: 2006. The
window size used for this calculation is 1230mm x 1480mm as
specified in BS EN ISO 12567: Part 1: 2000.
Glass to glass corners must be stepped glazing, which provide a
very slim corner joint.
Acoustic Rating: As required windows to be glazed with 28mm
sealed units comprising 4mm clear outer/20mm argon cavity/4mm
clear super low-e inner to provide a minimum Rw rating of 31dB
when tested in accordance with ISO 140-3:95 “Acoustics –
Measurement of sound insulation in buildings and of building
elements – Part 3: Laboratory measurement of airborne sound
insulation of building elements” at a size of 1185 x 1185mm,
Manufacturer to provide report of the individual frequency ratings
for approval.
Glass thickness and type to suit application. Laminated / toughened
to BS6206 & BS6262 where applicable
Manufacturer as per architect’s specification.
-Ironmongery / Accessories:
o Side and top hung projecting sashes to be fitted with a key locking
espagnolette handle and a non-locking restrictor.
o Fully reversible sashes to be fitted with a key locking espagnolette
handle and an integral hinge restrictor.
o Turn tilt / tilt slide / sliding sashes to be fitted with a key locking
espagnolette handle.
o Terrace doors opening out to be fitted with a key locking
espagnolette handle which operates a brake on the head.
o The window ironmongery to be generally manufactured from zinc
chromated steel with a matt chrome finish.
o Locking espagnolette brushed chromium plated (by FIX)
3
o
Titon Trimvent 90 if required to be surface mounted on the timber
framing profiles as indicated on the enclosed specification
schedules. Each trickle ventilator to provide an “Equivalent Area”
of 2510mm2 in accordance with EN 13141: Part 1: 2004 as
required to be measured by Building Regulations Approved
Document F: 2006.
Should a measurement of ‘Free Area’ be applicable to your project,
each ventilator will provide 4000mm2. Delete and replace with:
Free Area of trickle ventilators to provide 4000 mm2 per ventilator.
The system to have the ability to provide the option for Acoustic
trickle vents as per the architects drawings.
-Fixing:
o
To manufacturers recommendations by approved PRO TEC Installer
INSTALLATION
o
All PRO TEC windows and doors are to be installed vertically into
prepared openings. All PRO TEC products are internally glazed
except fixed lights which are externally glazed.
o
Suitable fixing grounds or interface materials to be provided by
others which are immediately adjacent to the product and allow
point loads to be used at centres in accordance with the standard
fixing positions.
Window and door elements are not to be utilised as structural
elements and no loads shall be imposed upon them other than
which they are expressly designed for. Their own dead weight and
the wind loads acting upon them (both individual and collective
frames) require to be transferred back to the grounds or interface
materials to which they are fixed.
Should the grounds be inadequate to take such point loads to
comply with BS 6399 Part 2, reinforced fixing brackets, a change in
substrate materials or re-design may be required, this to be
confirmed during manufacturing design stage and in conjunction
with the approved installer.
o
o
710 PROTECTION COMPONENTS
o
4
General: Components should not be delivered to site unless they
can be installed immediately or placed on an even support, away
from damp and dirt. Units not installed immediately must be
protected from weather and site contamination.
o
Stored components should be stacked vertically or near vertically
on level bearers, separated with spacers to prevent damage by and
to projecting ironmongery, beads, etc.
765 WINDOW INSTALLATION GENERALLY
o
o
o
o
Installation: Into prepared openings.
Gap between frame edge and surrounding construction: Nominal 10
mm. Where a cill pressing is to be installed allow 25mm
Installation before render
No requirements for render trims
Distortion: Install windows without twist or diagonal racking.
770 DAMP PROOF COURSES IN PREPARED OPENINGS
o
Location: Ensure correct positioning in relation to window
frames. Do not displace during fixing operations.
784 FIXING OF COMPOSITE FRAMES
o
Standard: As section Z20.
Fasteners: _______
- Spacing: When not predrilled or specified otherwise, position
fasteners not more than 150 mm from ends of each jamb,
adjacent to each hanging point of opening lights, and at
maximum 500 mm centres.
810 SEALANT JOINTS
o
o
o
5
Sealant: Manufacturer: Arbosil or similar
Product reference: 1096 silicone sealant or similar
Colour: TBC
Application: As section Z22 to prepared joints. Finish triangular
fillets to a flat or slightly convex profile.
Alternative material, Illmod 600 pre-compressed expanding
tape or an equal or approved tape.
Download