epicRealm Inc. PriorityRealm Network Phase 2 Global Installation Guide Dec. 5, 2000 Rev. 2.9 -- Final epicRealm Inc. 1651 N. Glenville Drive, Suite 212 Richardson, TX 75081 U.S.A. (214) 570-4404 Global_P2_V2.9 epicRealm Confidential 1 2 epicRealm Confidential Global_P2_V2.9 Table of Contents TRADEMARKS AND COPYRIGHTS......................................................................... 7 epicRealm Inc. Trademarks ................................................................................................................ 7 Other Trademarks ................................................................................................................................ 7 LIST OF CONTACTS .................................................................................................. 8 SCOPE OF WORK ........................................................................................................ 9 Overview ............................................................................................................................................... 9 INSTALLING SERVERS ............................................................................................ 11 Process ................................................................................................................................................. 11 Overview ............................................................................................................................................. 11 Parts List .............................................................................................................................................. 11 Hardware............................................................................................................................................................................. 11 Cables .................................................................................................................................................................................. 12 Miscellaneous ..................................................................................................................................................................... 12 Equipment Naming Conventions.................................................................................................... 12 Required Tools ................................................................................................................................... 13 Installation Tools ............................................................................................................................................................... 13 Installing Rack #1 .............................................................................................................................. 15 Overview ............................................................................................................................................................................. 15 Mounting an Altiga C15 VPN Router ........................................................................................................................... 15 Mounting the First Cabinet ............................................................................................................................................. 15 Installing a Cisco 3640 Access Router ........................................................................................................................... 15 Setting and Installing US Robotics Modem ................................................................................................................. 15 Installing Rack #2 .............................................................................................................................. 17 Overview ............................................................................................................................................................................. 17 Mounting a Foundry FastIron II Server ....................................................................................................................... 17 Mounting a Foundry ServerIron..................................................................................................................................... 17 Mounting the Servers for the Second Cabinet ............................................................................................................. 17 Installing a Cisco 3640 Terminal Server ........................................................................................................................ 17 Installing Rack #3 .............................................................................................................................. 19 Overview ............................................................................................................................................................................. 19 Mounting a Foundry FastIron II Server ....................................................................................................................... 19 Mounting a Foundry ServerIron..................................................................................................................................... 19 Mounting Servers in the Third Cabinet ......................................................................................................................... 19 Global_P2_V2.9 epicRealm Confidential 3 Installing Rack #4 .............................................................................................................................. 20 Overview ............................................................................................................................................................................. 20 Mounting the Servers for the Fourth Cabinet.............................................................................................................. 20 CONNECTING SERVERS .........................................................................................21 ONSITE CONFIGURATION USING WINDOWS NT .......................................... 23 Pre-configuring a Cisco 3640 Router .............................................................................................. 23 Automated Configuration ................................................................................................................................................ 23 Using Scripts to Configure a 3640 Gateway Router ..................................................................................................................... 23 Configuring Cisco 3640 Access Routers/Terminal Servers ........................................................ 24 Automated Configuration ................................................................................................................................................ 24 Using Scripts to Configure a Cisco 3640 Access Router ............................................................................................................. 24 Configuring the Altiga VPN Router ............................................................................................... 25 Standard VPN Configuration .......................................................................................................................................... 26 Configuring the Subnet Mask and Gateway for a ServerIron ..................................................... 29 .Configuring a FastIron II or Workgroup Switch ......................................................................... 29 Configuring a FastIron II or Workgroup Switch .......................................................................... 30 Configuring a New VLAN ............................................................................................................... 31 Configuring the First ServerIron for a VLAN ............................................................................................................. 31 Configuring the Second ServerIron for a VLAN ........................................................................................................ 31 Configuring the First FastIron II for a VLAN ............................................................................................................ 32 Configuring the Second FastIron II for a VLAN ....................................................................................................... 32 VLAN Diagram .................................................................................................................................. 34 APPENDICES ............................................................................................................. 35 APPENDIX A: THE BASICS ..................................................................................... 37 Changing a Laptop’s IP Address ..................................................................................................... 37 Opening a HyperTerminal Session.................................................................................................. 37 APPENDIX B: RACK LAYOUTS .............................................................................. 39 Rack #1 ............................................................................................................................................... 39 Rack #2 ............................................................................................................................................... 40 Rack #3 ............................................................................................................................................... 41 Rack #4 ............................................................................................................................................... 42 APPENDIX C: DEVICE SCHEMES ......................................................................... 43 4 epicRealm Confidential Global_P2_V2.9 Server Irons ......................................................................................................................................... 43 ServerIron 1 (SVI2X2) – Gig Ports ............................................................................................................................... 43 ServerIron 1 (SVI2X2) – Ethernet Ports ...................................................................................................................... 43 ServerIron 2 (SVI3X2) – Gig Ports ............................................................................................................................... 43 ServerIron 2 (SVI3X2) – Ethernet Ports ...................................................................................................................... 44 FastIron II Switches .......................................................................................................................... 44 FastIron II Switch 1 (SWI2X1) – Gig Ports ................................................................................................................ 44 Blade 1 .................................................................................................................................................................................................... 44 FastIron II Switch 1 (SWI2X1) – Ethernet Ports ....................................................................................................... 45 Blade 2 .................................................................................................................................................................................................... 45 Blade 3 .................................................................................................................................................................................................... 45 Blade 4 .................................................................................................................................................................................................... 45 FastIron II Switch 2 (SWI3X1) – Gig Ports ................................................................................................................ 46 Blade 1 .................................................................................................................................................................................................... 46 FastIron II Switch 2 (SWI3X1) – Ethernet Ports ....................................................................................................... 46 Blade 2 .................................................................................................................................................................................................... 46 Blade 3 .................................................................................................................................................................................................... 46 Blade 4 .................................................................................................................................................................................................... 47 Altiga VPN Router............................................................................................................................. 47 Cisco 3640 Terminal Server.............................................................................................................. 48 Module 1 ................................................................................................................................................................................................ 48 Module 2 ................................................................................................................................................................................................ 49 Module 3 ................................................................................................................................................................................................ 49 APPENDIX C: IP ADDRESSING ..............................................................................51 APPENDIX D: UPGRADING EQUIPMENT OS AND IOS................................... 53 Upgrading the Altiga VPN Router .................................................................................................. 53 Verifying the VPN OS Level........................................................................................................................................... 53 Upgrading the VPN Operating System .......................................................................................... 53 Upgrading a Foundry Workgroup Switch ...................................................................................... 54 Upgrading Cisco 2611 Access Routers/Terminal Servers ........................................................... 55 Verifying the Operating System of the Cisco 2611 Access Router .......................................................................... 55 Upgrading the Cisco 2611 Operating System .............................................................................................................. 55 If you are not sure about the setup or have questions call Buddy Lewis at 214-616-7987. .................................................. 56 Upgrading Cisco 3640 Routers ........................................................................................................ 56 Verifying the Operating System of the Cisco 3640 Router ....................................................................................... 56 Upgrading the Cisco 3640 Operating System .............................................................................................................. 56 QA CHECKLIST ......................................................................................................... 59 Installation Services ........................................................................................................................... 59 Global_P2_V2.9 epicRealm Confidential 5 6 epicRealm Confidential Global_P2_V2.9 Trademarks and Copyrights epicRealm Inc. Trademarks epicRealm and the epicRealm logo are trademarks or registered trademarks of epicRealm Inc. Other Trademarks Intel and Pentium are registered trademarks, and 486 is a trademark of Intel Corporation. Microsoft, MS are registered trademarks and Windows, MS Windows, Windows NT, Win32, Win32s, MS OLE, Visual C++, Visual Basic, VBX, ODBC, and MFC are trademarks of Microsoft Corporation. Sybase is a registered trademark of Sybase Inc. ORACLE is a registered trademark of Oracle Corporation. HP OpenView IT/O, are registered trademarks of Hewlett Packard Company Squid is a copyright of the University of California San Diego and Duane Wessels. LINUX is a registered trademark of Linus Torvalds. RED HAT is a registered trademark of Red Hat Inc. Sun and Solaris are registered trademark of Sun Microsystems, Inc. SiteScope is a registered trademark of Freshwater Software, Inc. Cisco is a registered trademark of Cisco Systems, Inc. This document is the property of and is proprietary to epicRealm Inc. It is not to be disclosed in whole or in part without the expressed written consent of epicRealm Inc., shall not be duplicated or used, in whole or in part, for any purpose, and shall be returned upon request. Global_P2_V2.9 epicRealm Confidential 7 List of Contacts epicRealm PriorityRealm Network Operations Team BRIAN HUNTER Network Implementation Manager Cell Phone: Work: 214-274-5382 214-570-4404 DAVID COBB NOC Manager Cell Phone: Work: 214-912-7649 214-570-4801 Cell Phone: Work: 214-868-6088 214-570-4440 Cell Phone: Work: 214-616-7987 214-570-4437 BRIAN HARDEN Project Manager BUDDY LEWIS Senior Project Manager NETWORK OPERATIONS CENTER 8 214-570-4800 (seven days/week; 24 hours/day) epicRealm Confidential Global_P2_V2.9 Scope of Work Overview START TIME: 8:00 a.m. sharp. The Field Service Engineer (FSE) will call the epicRealm co-location site to confirm the site location and site contacts 24 hours prior to arrival to the site. The FSE will call the epicRealm NOC on arrival to the co-location site to acknowledge the work is about to initiate. The FSE will confirm equipment location and rack location of equipment upon arrival, and will inventory and then record serial numbers of the equipment. This is to insure the proper equipment has arrived. The equipment is pre-configured according to site and will not work anywhere else. Before departure by the installation team, the system must be validated for network integrity. The FSE MUST call the epicRealm NOC to verify that everything is operational. [epicRealm NOC, {USA} 214570-4800] The system is required to be operational upon departure, and the FSE MUST call the NOC and verify that the equipment is operational. [NOC, (USA) 214-570-4800] Installation has four major objectives for Global and Local data centers. 1. Prepare the equipment and install in proper locations in the rack space. 2. Route all data cables and terminate to proper locations. 3. Quality assurance review. The epicRealm NOC will run a network assessment of all network hardware and server equipment to validate the integrity of the installation. In the event that something does not validate, there will be a phased debugging process to follow, requiring levels of logging in to network devices to troubleshoot, to upgrading configurations or operating systems. This process will be handled by the epicRealm NOC. 4. Install covers and dress cables in an appropriate manner. For example, use tie wraps to ease the weight on the NICs and servers and also to keep the cable matrix from blocking venting to allow for the best circulation possible. Global_P2_V2.9 epicRealm Confidential 9 10 epicRealm Confidential Global_P2_V2.9 Installing Servers Process The following provides a brief sequence of tasks involved in installing a data center: a. Inventory using the Parts List descriptions b. Install (or rack mount) all hardware c. Connect cables to appropriate ports or connectors on installed hardware d. Connect to the co-location ISP and power all hardware on e. Contact epicRealm's NOC to validate the integrity of the installation. If any part of the NOC validation fails, then a process of debugging will be staged at this time, from physical to network, and will be managed initially by TruSOLUTIONS’ deployment team. f. Cleanup and paperwork Overview This section includes a parts list to take inventory of equipment that was shipped, procedures for unpacking and preparing the equipment for installation, the rack layout plans for each of the two racks with their components labeled, and step-by-step installation procedures for each rack. The typical server rack layout for Global Data Centers requires two racks at each co-location site. See Appendix A for diagrams of the rack layouts. Parts List A Global installation of epicRealm's Network requires the following: Hardware 1 Altiga C15 VPN Router 1 Cisco 3640 Access Router (Terminal Server) 1 Cisco 3640 Gateway Router 2 Foundry FCSLB8+2G ServerIron (8XL) Global_P2_V2.9 epicRealm Confidential 11 2 Foundry F21708 FastIron Plus II 60 1U VA/Linux servers (TruSOLUTIONS) 1 33.6 Modem Cables 10 Octal Cables (68pin to RJ45) -20' 16 sc to sc fiber cables (8 -1meter, 8 - 8meter) 1 DB9F to DB25M 10' cable 5 CAT5 25' BLK Crossover cables 70 CAT5 Red Patch cables (assorted 5', 10' 20') 70 CAT5 Blue Patch cables (assorted 5', 10' 20') Miscellaneous 2 Packages 8" blk tie wraps 60 1U23 RJ45 to DB9FAdapters 1 Altiga RJ45 to DB9FAdapter 4 Foundry RJ45 to DB9FAdapters Equipment Naming Conventions Each piece of equipment is identified by a three-character acronym, followed by the rack number in which it is installed, and its position in the rack. For example, an Altiga VPN router positioned in the first rack as the first device in the rack would be identified as VPN1X1. A server in the fourth position on rack 2, would be identified as SRV2X4. The following three-letter acronyms identify each piece of equipment: RTR = router SVI = Foundry ServerIron GLB = global load balancer LLB = local load balancer 12 epicRealm Confidential Global_P2_V2.9 SWI = Foundry Workgroup Switch or Foundry FastIron II Switch SRV = server VPN = Altiga VPN router MDM = modem TRM = Cisco terminal server (or access router) SUN = Sun box Required Tools These tools are required before going to a site installation . Do not attempt an installation without these: Installation Tools 1. Laptop with Windows 98-2000/NT - must have an active serial port and active 10/100 NIC card 2. HyperTerminal (v.5 recommended) 3. Latest operating version for: a. Altiga VPN Router b. Foundry Workgroup c. Foundry ServerIron d. Gateway router e. Access router 4. TFTP server/client 5. Altiga serial cable - (straight through 9 to 9 F-F) 6. Cisco serial cable with 9 pin adapter 7. Cross over patch cable 8. Straight through patch cable 9. electric drill set with flat and phillips tool bits 10. regular flat head and phillips head screwdriver (just in case) 11. socket set or crescent wrench and pliers Global_P2_V2.9 epicRealm Confidential 13 12. snips (or heavy duty scissors) 13. telephone (Some debugging during the process may be required, so phone access for dial out to the epicRealm NOC is required, either provided by the installer or the site co-location center. A phone with a headset is ideal.) 14 epicRealm Confidential Global_P2_V2.9 Installing Rack #1 Overview Rack #1 will contain an Altiga C15 VPN router, four Global Name Servers, one back-end Apache server, two flow control servers, two parent servers, eight sibling servers, a Cisco 3640 access router, and a US Robotics modem. For a rack plan layout of Rack #1, see Appendix A: Rack Layouts. Mounting an Altiga C15 VPN Router To mount the Altiga C15 VPN router: 1. Place the Altiga VPN (VPN1X1) router in the bottom slot of the first rack. 2. Secure the VPN router with two rack screws on each side. Mounting the First Cabinet After mounting the VPN router, mount the first set of TruSOLUTIONS servers. To mount the servers: 1. Mount the first TruSOLUTIONS server (SRV1X2) in the slot above VPN1X1, and secure it with two rack screws on all sides. 2. Mount the next 16 servers (SRV1X3-SRV1X18) directly above SRV1X2, securing each on all sides with two rack screws. 3. Repeat Step 3 for mounting SRV1X19, leaving space between SRV1X18 and SRV1X19. Installing a Cisco 3640 Access Router A Cisco 3640 Access Router is installed at every Global site. To install the Cisco 3640: 1. Mount the Cisco 3640 Access Router (RTR1X20) at the top of Rack #1 directly above the marketing SRV1X19. Some sites do not have a marketing server, so at those sites, install the Cisco 3640 above the last server installed. 2. Secure it on both sides with two rack screws. Setting and Installing US Robotics Modem Global_P2_V2.9 epicRealm Confidential 15 A US Robotics modem is installed at every Global site directly above the Cisco 3640 Access Router (RTR1X20) in Rack #1. Before installing the modem, you must set the modem dip switch. To set the modem’s dip switch and install the modem: 1. On the bottom of the modem, find the dip switch (a series of small white switches found inside a rectangular opening). Use the following diagram to turn each switch in either the On or Off position: 2. Mount the modem directly above the Cisco 3640 Access Router (RTR1X20) in Global Rack #1. 3. Secure it on both sides with two rack screws. See Appendix B: Rack Layouts for rack plans. 16 epicRealm Confidential Global_P2_V2.9 Installing Rack #2 Overview Rack #2 contains a Foundry FastIron II, a Foundry ServerIron, 14 TruSOLUTIONS servers. For a rack plan layout of Rack #2, see Appendix A: Rack Layouts. Mounting a Foundry FastIron II Server Mount one of the Foundry FastIron II servers. To mount the FastIron II: 1.Place the FastIron II (SWI2X1) in the bottom slot of the second rack. 2.Secure the FastIron II with two rack screws on each side. Mounting a Foundry ServerIron To mount a Foundry ServerIron: 1. Place one of the Foundry ServerIrons (SVI2X2) directly above the FastIron II server. 2. Secure the ServerIron with two rack screws on each side. Mounting the Servers for the Second Cabinet After mounting the Foundry ServerIron, mount the TruSOLUTIONS servers for rack two. To mount the servers: 1. Mount the SRV2X3 in the slot directly above the ServerIron, securing it with two rack screws on all sides. 2. Mount the next TruSOLUTIONS servers (SRV2X4-SRV2X15) in the slot above SRV2X3, and secure them with two rack screws on all sides. Installing a Cisco 3640 Terminal Server A Cisco 3640 Terminal Server is installed at every Global site. There are two Cisco 3640 boxes installed at a Global site, one as a gateway router (installed in Rack #1) and one installed as a terminal server. The 3640 used as a terminal server is identified by ten modules for octopus cables in the back. To install the Cisco Global_P2_V2.9 epicRealm Confidential 17 3640 Terminal Server: 1. Mount the Cisco 3640 Terminal Server (TRM2X16) directly above (SRV2X15) that was just installed in Global Rack #2. 2. Secure it with two rack screws on each side. 3. Connect the async connections to all servers (via LAN 2) and network devices. Verify that the correct adapters are used. 18 epicRealm Confidential Global_P2_V2.9 Installing Rack #3 Overview Rack #3 contains a Foundry FastIron II, a Foundry ServerIron, and 12 TruSOLUTIONS servers. For a rack plan layout of Rack #3, see Appendix A: Rack Layouts. Mounting a Foundry FastIron II Server Mount one of the Foundry FastIron II servers. To mount the FastIron II: 1. Place the FastIron II (SWI3X1) in the bottom slot of the second rack. 2. Secure the FastIron II with two rack screws on each side. Mounting a Foundry ServerIron To mount a Foundry ServerIron: 1. Place one of the Foundry ServerIrons (SVI3X2) directly above the FastIron II server (SWI3X1). 2. Secure the ServerIron with two rack screws on each side. Mounting Servers in the Third Cabinet After mounting the Foundry ServerIron (SVI3X2), mount the TruSOLUTIONS servers. To mount the servers: 1. Mount the first server (SRV3X3) in the slot directly above the ServerIron (SVI3X2), securing it with two rack screws on all sides. 2. Mount the next 11 TruSOLUTIONS servers (SRV3X4-SRV3X14) in the slot above SRV3X3, and secure them with two rack screws on all sides. Global_P2_V2.9 epicRealm Confidential 19 Installing Rack #4 Overview Rack #4 contains a total of 17 TruSOLUTIONS servers. For a rack plan layout of Rack #4, see Appendix A: Rack Layouts. Mounting the Servers for the Fourth Cabinet Mount the remaining TruSOLUTIONS servers in Rack # 4, starting in the bottom slot. To mount the servers: 1. Mount the first server (SRV4X1) in the slot in the bottom of Rack #4, securing it with two rack screws on all sides. 2. Mount the remaining TruSOLUTIONS servers (SRV4X2-SRV4X17) in the slot above SRV4X1, and secure it with two rack screws on all sides. 20 epicRealm Confidential Global_P2_V2.9 Connecting Servers The Foundry FastIron Workgroup Switch and ServerIron provide a central point to which all servers and routers connect. Each TruSOLUTIONS server and Altiga VPN router are connected to either the FastIron Workgroup Switch or the ServerIron via a blue cable and a red cable. The blue cable provides the public connection, and the red cable provides the private connection for each box. The blue cable provides the public connection by plugging into the bottom Network Interface Card (NIC) on the back of the servers and into the second Ethernet port on the VPN routers. The other blue end connects to a port on the FastIron Workgroup Switch or ServerIron. The red cable provides the private connection by plugging into the top NIC on the back of the servers and into the first Ethernet port on the VPN routers. The other red end connects to a port on the FastIron Workgroup Switch or ServerIron. The ports on the Foundry FastIron Workgroup Switch and Foundry ServerIron to which the servers, routers and terminal server connect are detailed in the Device Schemes section of the Appendix. Use these cable diagrams to identify the slot and port to which each server and router will be connected and the rack layouts in the Appendix section titled Rack Layouts in identifying the equipment. After the equipment is mounted into the rack space and everything is cabled, verify that the connection to the hosting ISP has been connected. Then power up all of the devices. Do NOT power cycle the boxes more than once. In other words, do not turn things off and on, as the systems, especially servers, have a boot cycle they need to complete. Allow all systems to cycle on. A quick check of the link lights between patch cables may give immediate indications of problems, such as bad cables between network devices, hardware failures, or other problems. After all devices are powered on, call epicRealm's NOC to have them validate the data center (214-570-4800). CAUTION: Installers must stay on site until the data center is validated. To validate a site, the NOC must see all devices through the network. If there is a problem, proceed to the next phase of debugging the installation under the NOC’s guidance. See Appendix B for Port Layout Diagrams. Global_P2_V2.9 epicRealm Confidential 21 22 epicRealm Confidential Global_P2_V2.9 Onsite Configuration Using Windows NT Pre-configuring a Cisco 3640 Router Prior to configuring a Cisco 3640 router, the following equipment is required: 1. Laptop with serial port interface 2. HyperTerminal Version 5 or newer, or a terminal program that sends a break character 3. Roll-over cable 4. Ethernet card (10/100 preferred) 5. Cisco console cable and adapter 6. tftp server (recommend TFTPD32 Version 1.3 or newer) 7. All Cisco configuration files accessible from the tftp server root 8. Configuration documentation 9. Working knowledge of Cisco and Windows Before beginning configuration, be sure the roll-over cable is plugged into the fast Ethernet 0/0 port on the router, and the laptop is plugged into the port labeled Console. Automated Configuration Using Scripts to Configure a 3640 Gateway Router Use the following procedures if you have access to the template configuration scripts for the 3640 gateway router or access router: To set up a 3640 router as a gateway router or access router using scripts: 1. Open the router template either for a gateway router or access router, depending on which is being set up on the Cisco 3640. This information will be provided to you. 2. Change the text that displays in red to match the site-specific information. Change the following information: site name = usually the data center name (such as dfw1a) Global_P2_V2.9 epicRealm Confidential 23 enable secret = penguin 0/1 IP (public) = X.X.X.X (See Public Net field on the chart for the correct IP address.) 0/0 IP (carrier) = X.X.X.X (See Carrier Net field on the chart for the correct IP address.) IP route = X.X.X.X (See Carrier Router field on the chart for the correct IP address, and delete the rest of the line in the script after typing in the correct address.) 3. Copy the entire script. 4. Close the file without saving the changes, however be sure to make note of the new password listed in the file (black text). 5. Return to the HyperTerminal console, and type en. 6. Type config t. 7. From the Edit menu, select Paste to host. 8. Make sure the word end is included at the end of the pasted text. If not, type end. 9. Type wr mem. 10. Type reload. 11. Press ENTER to confirm. 12. Log in to the router by typing the new password (noted in Step 3). 13. Type en. 14. Type the password penguin. 15. Type sh ip int br. Make sure the status of fastethernet0/1 is up, with the protocol status down. 16. Type sh ver to make sure the IOS version number running on the Cisco router is 12.1 (1)t. Configuring Cisco 3640 Access Routers/Terminal Servers Automated Configuration Use the automated configuration process if you have access to the configuration templates. If not, use the manual configuration process. Using Scripts to Configure a Cisco 3640 Access Router Before configuration can be successful, the existing router configuration should be erased. Contact Buddy Lewis at 214-570-4437. If the box contains no existing configuration, use the following configuration 24 epicRealm Confidential Global_P2_V2.9 procedures: 1. Login (using f00tba11) and check the IP configurations. 1. Type en and press ENTER. 2. Type the password penguin. 3. Type show run to view the configuration. 4. Compare the configurations to the IP addresses given to you for this specific site. 2. Open the router template for the Cisco 3640 access router. This information will be provided to you. 3. Change the text that displays in red to match the site-specific information. Change the following information: site name = usually the data center name (such as dfw1a) enable secret = penguin private IP = 10.X.X.15 (See TRM2X15 on the chart for the correct, site-specific IP) IP route = 10.X.X.11 (See VPN1X1 on the chart for the correct, site-specific IP, then delete the rest of the line in the script after typing in the correct IP.) 4. Copy the entire script. 5. Close the file without saving the changes, however be sure to make note of the new password listed in the file (in black text). 6. Return to the HyperTerminal console, and type en. 7. Type the password penguin. 8. Type config t. 9. From the Edit menu, select Paste to host. 10. Make sure the word end is included at the end of the pasted text. If not, type end. 11. Type wr mem. 12. Type reload. 13. Press ENTER to confirm. 14. Log in to the router by typing the new password (noted in Step 3). 15. Type en. 16. Type the password penguin. 17. Type sh ip int br. Make sure the status of fastethernet0/1 is up, with the protocol status down. If the status is down, check the cable connections. Configuring the Altiga VPN Router Global_P2_V2.9 epicRealm Confidential 25 Standard VPN Configuration 1. Plug laptop or dumb terminal into the console via the 9 pin serial cable. Connect the two using HyperTerminal by opening a HyperTerminal window from the Windows Start menu. (See Appendix A for Hypterminal setup.) 2. In the Dial by Using dropdown list box select Com 1 (or the port needed for your current laptop configuration). 3. Turn on the Altiga VPN router. 4. Type the login name "admin" at the Login prompt. 5. Type "admin" as the password. 6. When prompted to enter the time, set the system time in the following format: HH:MM:SS. Example: 21:30:00 for 9:30 PM The time displays at the Quick - > prompt. Note: The correct time is very important, so that logging and accounting entries are accurate. 7. Enter the date in the following format at the > Date Set prompt. If the date is accurate, press ENTE to accept the default. MM/DD/YYYY Example: 06/12/1999 for June 12th 1999 The date displays at the Quick - > prompt. 8. Type the number representing the correct time zone at the >Time Zone prompt using the following table. Note: The correct time zone is very important so that logging and accounting entries are accurate. 9. At the Quick -> prompt, type 1 to select Enable DST Support. 10. A table displays the current IP addresses. The first column indicates the interface; the second indicates IP address/subnet mask; and the third column indicates the MAC address. 11. At the Quick > prompt, enter the IP address for Ethernet 1 (Private). The fourth octet in the IP address is .11 by default, indicating VPN. Example: xx.xx.xx.11 12. At the Quick > prompt, enter the subnet mask for Ethernet 1. Type 255.255.255.0. The result should look like a table showing the current IP addresses. Interface IP Address/Subnet Mask MAC Address ------------------------------------------------------------------------------| Ethernet 1 - Private | x.x.x.11/255.255.255.0 | 00.90.A4.00.05.6C 26 epicRealm Confidential Global_P2_V2.9 | Ethernet 2 - Public | x.x.x.11/255.255.255.0 | 00.90.A4.00.05.6D | Ethernet 3 - External | 0.0.0.0/0.0.0.0 | 13. At the Quick > prompt, press ENTER to accept the default of 3 to select Ethernet Speed 10/100 Mbps Auto Detect. 14. At the Quick > prompt, enter 1 to select half/full/auto duplex. 15. At the Quick > prompt, type 2 to modify the Ethernet 2 IP address (public). 16. Follow Steps 8 through 11 for each Ethernet port to be configured. The installation procedures also detail these steps again for each Ethernet port. 17. At the prompt, type 4 to save the changes. 18. At the prompt, type 6 to exit. 19. Log back in. 20. Select 1 for Configuration. 21. Select 2 for System Management. 22. Select 4 for IP Routing. 23. Select 2 for Default Gateways. 24. Select 1 to set the default gateway. 25. Type the default gateway, which is the same as the public default gateway. For the gateway router, use the public IP address in the Public GW field on the chart given to you. 26. Select 2 for Set Default Gateway Metric. 27. Type a metric of 1, which is the default. 28. Select 5 to go back. 29. Type 7 to go back. 30. Type 8 to go back. 31. Type 5 to go back. 32. Type 4 to save the changes. 33. Type 6 to exit. 34. Log back in. 35. Type 1 to select Configure. Global_P2_V2.9 epicRealm Confidential 27 36. Type 4 to select Policy Management. 37. Type 2 to select Traffic Management. 38. Type 4 to select Filters. 39. Type 4 to select Assign Rules to a Filter. 40. When asked which filter to assign rules to, type the following entire syntax without the quotes: "Public (Default)" Note: The system is case sensitive. 41. Type 1 to add a rule to a filter. 42. Type 16 to select Incoming HTTP In. 43. Type 1 to add another rule to a filter. 44. Type 17 to select Incoming HTTP Out. 45. Type 6 to back out of the configuration process. 46. Type 5 to back out of the configuration process. 47. Type 6 to back out of the configuration process. 48. Type 3 to back out of the configuration process. 49. Type 5 to back out of the configuration process. 50. Type 4 to save the changes. 51. Type 6 to exit. 28 epicRealm Confidential Global_P2_V2.9 Configuring the Subnet Mask and Gateway for a ServerIron 1. Plug the laptop into the ServerIron using the console port. 2. Make sure the flow control is disabled using the terminal emulator. Change the properties of the HyperTerminal session by clicking the Properties icon and changing the following parameters: Bits per second: 9600 Flow control: none Click the Save button, then click the Close button. 3. Start a terminal emulation session, such as Hyper Terminal. A basic boot prompt displays with the generic box name and a prompt: ServerIron> 4. Type en for enable. No password is necessary initially. 5. Type conf t. 6. Type ip address, and type the IP address and subnet mask in this format. ServerIron: XXX.XXX.XX 255.255.255.XXX Note: See the IP address chart for the correct IP address for this site. Press Enter. 7. Type ip def and then type the IP gateway address. Press Enter. 8. Type hostname (space), followed by the site ID and the name of the ServerIron. 9. Type write mem. 10. Type end, and press ENTER. 11. Type exit, and press ENTER. . Global_P2_V2.9 epicRealm Confidential 29 Configuring a FastIron II or Workgroup Switch 1. Plug the laptop into the FastIron II using the console port. 2. Make sure the flow control is disabled using the terminal emulator. Change the properties of the HyperTerminal session by clicking the Properties icon and changing the following parameters: Bits per second: 9600 Flow control: none Click the Save button, then click the Close button. 3. Start a terminal emulation session, such as Hyper Terminal. A basic boot prompt displays with the generic box name and a prompt: FastIron II> 4. Type en for enable. No password is necessary initially. 5. Type conf t. 6. Type ip address, and then type the actual public IP address and subnet mask. Press Enter. FastIron II: XXX.XXX.XX 255.255.255.XXX Note: See the IP address chart for the correct IP address for this site. 7. Type ip def, and type the IP gateway address. Press Enter. 8. Type hostname (space), followed by the name of the FastIron II or Workgroup. 9. Type write mem. 10. Type end, and press ENTER. 11. Type exit, and press ENTER. 30 epicRealm Confidential Global_P2_V2.9 Configuring a New VLAN Configuring the First ServerIron for a VLAN 1. Turn the Server Iron on by plugging it in. 2. Plug your laptop into the front of the ServerIron. 3. Open a HyperTerminal session. 4. Press the enter key. 5. Type the word “enable” and press the enter key 6. Do a copy and paste for the script below config t default-vlan 4095 vlan 1 name private by port tag e9 untag e1 e5 e7 vlan 2 name public by port tag e9 untag e2 e6 e8 vlan 3 name isp by port tag e9 untag e3 e4 exit write memory Configuring the Second ServerIron for a VLAN 1. Turn the Server Iron on by plugging it in. 2. Plug your laptop into the front of the ServerIron. 3. Open a HyperTerminal session. 4. Press the enter key. 5. Type the word “enable” and press the enter key 6. Do a copy and paste for the script below config t Global_P2_V2.9 epicRealm Confidential 31 default-vlan 4095 vlan 1 name private by port tag e9 e10 untag e1 e5 e7 vlan 2 name public by port tag e9 e10 untag e2 e4 e6 e8 vlan 3 name isp by port tag e9 untag e3 exit wr me Configuring the First FastIron II for a VLAN 1. Turn the Workgroup switch on by plugging it in. 2. Plug your laptop into the front of the ServerIron. 3. Open a HyperTerminal session. 4. Press the enter key. 5. Type the word “enable” and press the enter key 6. Do a copy and paste for the script below: config t default-vlan 4095 vlan 1 name private by port tag e1/2 untag e2/1 e2/3 e2/5 e2/7 e2/9 e2/11 e2/13 e2/15 e2/17 e2/19 e2/21 e2/23 untag e3/1 e3/3 e3/5 e3/7 e3/9 e3/11 e3/13 e3/15 e3/17 e3/19 e3/21 e3/23 untag e4/1 e4/3 e4/5 e4/7 e4/9 e4/11 e4/13 e4/15 e4/17 e4/19 e4/21 e4/23 vlan 2 name public by port tag e1/2 untag e2/2 e2/4 e2/6 e2/8 e2/10 e2/12 e2/14 e2/16 e2/18 e2/20 e2/22 e2/24 untag e3/2 e3/4 e3/6 e3/8 e3/10 e3/12 e3/14 e3/16 e3/18 e3/20 e3/22 e3/24 untag e4/2 e4/4 e4/6 e4/8 e4/10 e4/12 e4/14 e4/16 e4/18 e4/20 e4/22 e4/24 exit wr me Configuring the Second FastIron II for a VLAN 1. Turn the Workgroup switch on by plugging it in. 2. Plug your laptop into the front of the ServerIron. 32 epicRealm Confidential Global_P2_V2.9 3. Open a HyperTerminal session. 4. Press the enter key. 5. Type the word “enable” and press the enter key 6. Do a copy and paste for the script below config t default-vlan 4095 vlan 1 name private by port tag e1/1 e1/2 untag e2/1 e2/3 e2/5 e2/7 e2/9 e2/11 e2/13 e2/15 e2/17 e2/19 e2/21 e2/23 untag e3/1 e3/3 e3/5 e3/7 e3/9 e3/11 e3/13 e3/15 e3/17 e3/19 e3/21 e3/23 untag e4/1 e4/3 e4/5 e4/7 e4/9 e4/11 e4/13 e4/15 e4/17 e4/19 e4/21 e4/23 vlan 2 name public by port tag e1/1 e1/2 untag e2/2 e2/4 e2/6 e2/8 e2/10 e2/12 e2/14 e2/16 e2/18 e2/20 e2/22 e2/24 untag e3/2 e3/4 e3/6 e3/8 e3/10 e3/12 e3/14 e3/16 e3/18 e3/20 e3/22 e3/24 untag e4/2 e4/4 e4/6 e4/8 e4/10 e4/12 e4/14 e4/16 e4/18 e4/20 e4/22 e4/24 exit wr me Global_P2_V2.9 epicRealm Confidential 33 VLAN Diagram Global_P2_V2.9 epicRealm Confidential 34 Appendices Global_P2_V2.9 epicRealm Confidential 35 36 epicRealm Confidential Global_P2_V2.9 Appendix A: The Basics Changing a Laptop’s IP Address To change your laptop’s IP address to that of the device to which you are connecting: 1. From the Windows Start menu, click Settings, Control Panel. 2. Click Network. 3. Click the Protocols tab. 4. Click TCP/IP Protocol, and click the Properties button. 5. Type the IP address within the range issued to the private address side for the device to which you are connecting. For example, if the Altiga is 10.2.3.11 and the subnet mask is 255.255.255.0, type 10.2.3.12 for the IP address and 255.255.255.0 for the subnet mask. 6. Click OK. 7. If using Windows 98, reboot. You should not have to reboot if using Windows NT. 8. Test by pinging the router from your DOS prompt. Opening a HyperTerminal Session To open a HyperTerminal session: 1. Open a HyperTerminal window from the Windows Start menu by selecting Programs, Accessories, HyperTerminal. 2. Select HyperTerminal from the HyperTerminal submenu. 3. Type a name for the HyperTerminal session in the Name window, and click OK. 4. In the Connect To window, select Com 1 (or the port needed for your current laptop configuration) in the Connect Using box. 5. Click the OK button. 6. In the COM1 Properties window, set the following parameters: Bits per second: 9600 Parity: none Stop bits: 1 Flow control: none 7. Click the OK button to connect. Global_P2_V2.9 epicRealm Confidential 37 38 epicRealm Confidential Global_P2_V2.9 Appendix B: Rack Layouts Rack #1 Legend: RTR = Cisco router SVI = Foundry ServerIron SWI = Foundry Workgroup Switch or Foundry FastIron II Switch SRV = TruSOLUTIONS server VPN = Altiga VPN router MDM = US Robotics modem TRM = Cisco terminal server Note: Do not leave space between the servers. Global_P2_V2.9 epicRealm Confidential 39 Rack #2 Legend: RTR = Cisco router SVI = Foundry ServerIron SWI = Foundry Workgroup Switch or Foundry FastIron II Switch SRV = TruSOLUTIONS server VPN = Altiga VPN router MDM = US Robotics modem TRM = Cisco terminal server 40 epicRealm Confidential Global_P2_V2.9 Rack #3 Legend: RTR = Cisco router SVI = Foundry ServerIron SWI = Foundry Workgroup Switch or Foundry FastIron II Switch SRV = TruSOLUTIONS server VPN = Altiga VPN router MDM = US Robotics modem TRM = Cisco terminal server Global_P2_V2.9 epicRealm Confidential 41 Rack #4 Legend: RTR = Cisco router SVI = Foundry ServerIron SWI = Foundry Workgroup Switch or Foundry FastIron II Switch SRV = TruSOLUTIONS server VPN = Altiga VPN router MDM = US Robotics modem TRM = Cisco terminal server 42 epicRealm Confidential Global_P2_V2.9 Appendix C: Device Schemes Server Irons ServerIron 1 (SVI2X2) – Gig Ports SVI 3X2 Open 1 2 ServerIron 1 (SVI2X2) – Ethernet Ports TRM 2x17 E0/0 ISP A 1 3 5 7 2 4 6 8 RTR 1X20 (FE0/0) RTR 1X20 (FE0/1) SRV1X2 SRV1X3 OPEN OPEN Note: LAN 1 = Private connection, with red cable, in odd-numbered port. LAN 2= Public connection, with blue cable, in even-numbered port. ServerIron 2 (SVI3X2) – Gig Ports SVI 2X2 SWI 3X1 1 2 Notes: After connecting the ISP to the switch, verify the green link light is working. If not, check to be sure the correct cables were used. Global_P2_V2.9 epicRealm Confidential 43 Use the blue, straight-through cables for ISP connections. If a link light does not come on, make sure the switch is powered on. You may try a black cross-over cable if the blue straight-through cable does not work. For the servers, use the red cables for LAN 1, the private connection (odd-numbered, top ports). For the servers, use the blue cables for LAN 2, the public connections (even-numbered, bottom ports). After completing the cabling, connect the fiber ports and power up the boxes. ServerIron 2 (SVI3X2) – Ethernet Ports ISP B OPEN OPEN OPEN 1 3 5 7 2 4 6 8 OPEN OPEN OPEN OPEN FastIron II Switches FastIron II Switch 1 (SWI2X1) – Gig Ports Blade 1 OPEN 1 SWI 3X1 Gig port 2 2 OPEN OPEN OPEN OPEN OPEN Externa l 3 4 5 6 7 SWI 2X1, B4, P12 Use blue cabl e) OP EN 44 epicRealm Confidential Global_P2_V2.9 FastIron II Switch 1 (SWI2X1) – Ethernet Ports Blade 2 SRV 1X2 SRV 1X3 1 3 5 7 2 4 6 8 SRV 1X3 SRV 1X4 SRV 1X5 SRV 1X2 SRV 1X4 SRV 1X5 SRV 1X6 SRV 1X7 SRV 2X3 9 11 13 15 17 19 21 23 10 12 14 16 18 20 22 24 SRV 2X4 SRV 2X5 SRV 2X6 SRV 2X7 SRV 2X8 SRV 2X10 SRV 2X11 SRV 2X12 SRV 2X13 SRV 2X14 SRV 1X6 SRV 1X7 SRV 2X3 SRV 2X4 SRV 2X5 SRV 2X6 SRV 2X7 SRV 2X8 Blade 3 SRV 1X8 SRV 1X9 SRV 1X11 SRV 1X12 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 SRV 1X8 SRV 1X9 SRV 1X10 SRV 1X11 SRV 1X12 SRV 1X13 SRV 1X10 SRV 1X13 SRV 2X9 SRV 2X9 SRV 2X10 SRV 2X11 SRV 2X12 SRV 2X13 SRV 2X14 OPEN SRV 2X15 SRV 2X16 Blade 4 SRV 1X14 SRV 1X15 SRV 1X17 SRV 1X18 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 SRV 1X14 SRV 1X15 SRV 1X16 SRV 1X17 SRV 1X18 VPN 1X1 OPEN OPEN OPEN SRV 1X16 Global_P2_V2.9 VPN 1X1 OPEN epicRealm Confidential OPEN OPEN OPEN SRV 2X15 45 SRV 2X16 FastIron II Switch 2 (SWI3X1) – Gig Ports Blade 1 SVI 3X2 Gig Port 2 SWI 2X1 Gig port 2 2 1 OPEN OPEN OPEN OPEN OPEN OPEN 3 4 5 6 7 8 FastIron II Switch 2 (SWI3X1) – Ethernet Ports Blade 2 SRV 3X3 SRV 3X4 SRV 3X5 SRV 3X6 SRV 3X7 SRV 3X8 SRV 4X1 SRV 4X2 SRV 4X3 SRV 4X4 SRV 4X5 SRV 4X6 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 SRV 3X5 SRV 3X6 SRV 3X7 SRV 3X8 SRV 4X1 SRV 4X2 SRV 4X3 SRV 4X4 SRV 4X5 SRV 4X6 SRV 3X10 SRV 3X11 SRV 3X12 SRV 3X13 SRV 3X14 SRV 4X7 SRV 4X8 SRV 4X9 SRV 4X10 SRV 4X11 SRV 4X12 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 SRV 3X10 SRV 3X11 SRV 3X12 SRV 3X13 SRV 3X14 SRV 4X7 SRV 4X8 SRV 4X10 SRV 4X11 SRV 3X3 SRV 3X4 Blade 3 SRV 3X9 SRV 3X9 46 epicRealm Confidential SRV 4X9 Global_P2_V2.9 SRV 4X12 Blade 4 SRV 4X14 SRV 4X15 SRV 4X16 SRV 4X17 INK OPEN OPEN 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 SRV 4X15 SRV 4X16 SRV 4X17 INK OPEN OPEN SRV 4X13 SRV 4X13 SVI 3X2 P5 SVI 3X2 P7 OPEN OPEN 17 19 21 23 18 20 22 24 SVI 3X2 P8 OPEN SVI 3X2 P6 Altiga VPN Router SWI2X1, B4, P11 (Use red cable ) Private Public Global_P2_V2.9 epicRealm Confidential 47 OPEN Cisco 3640 Terminal Server Module 1 SRV2X4 SRV2X5 SRV2X7 SRV2X6 4 SRV2X3 6 5 SRV2X8 7 SRV1X17 SRV1X18 1 8 SPARE05 2 RTR1X20 3 4 SPARE01 5 3 SVI2X2 2 Async Range 16-23 Async Range 24-31 7 SPARE03 8 1 SWI2X1 SPARE02 6 SPARE04 SRV1X9 1 SRV1X10 Async Range 8-15 SRV1X8 Async Range 0-7 8 2 6 3 SRV1X11 4 5 6 7 1 2 3 4 SRV1X7 7 SRV1X6 5 8 SRV1X5 SRV1X12 SRV1X13 SRV1X14 SRV1X15 SRV1X16 VPN1X1 SRV1X2 SRV1X3 SRV1X4 Note: For the IBM Netfinity servers, connect the terminal server to serial port B. For the TruSOLUTIONS servers, connect the terminal server to Com 2. Note: Verify port layouts are accurate, sign and fax diagrams to the NOC at 214-5704821. 48 epicRealm Confidential Global_P2_V2.9 Module 2 SRV4X6 SRV4X5 SRV4X8 SRV4X7 6 5 4 SRV4X4 SRV4X9 7 SRV3X8 SRV3X9 8 1 SRV3X10 2 SRV3X11 3 4 5 2 Async Range 24-31 Async Range 16-23 7 1 SRV4X2 SRV3X13 6 3 SRV4X3 SRV3X12 SRV3X14 8 SRV4X1 1 NRS2X18 Async Range 0-7 Async Range 8-15 8 SRV2X16 2 SWI3X1 7 3 4 SVI3X2 5 SRV3X3 SRV3X4 6 7 SRV3X5 SRV3X6 6 1 8 SRV3X7 SRV2X15 2 SRV2X9 3 SRV2X10 4 SRV2X11 5 SRV2X14 SRV2X12 SRV2X13 Module 3 SPARE SPARE SPARE SPARE 6 5 4 SPARE SPARE 7 SPARE SPARE 8 1 SPARE 2 SPARE 3 4 5 SPARE SPARE SPARE 6 3 SPARE SPARE 2 Async Range 24-31 Async Range 16-23 7 1 SPARE 8 SPARE 1 Async Range 0-7 Async Range 8-15 8 SRV4X17 2 SPARE 7 3 SPARE SPARE 4 5 SPARE 6 SPARE Global_P2_V2.9 7 SPARE 1 8 SPARE SRV4X10 epicRealm Confidential SRV4X16 6 2 SRV4X11 3 SRV4X12 4 5 SRV4X13 SRV4X15 SRV4X14 49 50 epicRealm Confidential Global_P2_V2.9 Appendix C: IP Addressing IP addresses are required for configuring network equipment such as the Altiga VPN Router and the Cisco 3640 Router. The following equipment requires public IP addresses, which will change per site. Cisco 3640 (RTR1X20) Foundry ServerIron (SVI2X2 and SVI3X2) Foundry FastIron II Switches (SWI3X1 and SWI2X1) The following equipment will have private IP addresses (beginning with 10) with the last octet being consistent from site to site: All TruSOLUTIONS servers (SRV1X2 to SRV4X17) – see the server number on the chart provided for correct IP addresses. Cisco 2611 (TRM2X17) – will end in .15. Altiga VPN Router (VPN1X1) – will end in .11. Members of epicRealm’s Implementation team can access site-specific IP address from the Access Database located at \\Vegas\Network Operations\IP Assignments\ip addressing.mdb. Global_P2_V2.9 epicRealm Confidential 51 52 epicRealm Confidential Global_P2_V2.9 Appendix D: Upgrading Equipment OS and IOS Upgrading the Altiga VPN Router Verifying the VPN OS Level Check the operating system level on the Altiga VPN concentrator and confirm it is OS level 2.2. To check the OS level: 1. Change your laptop IP address and subnet mask to be in the same range as the Altiga (10.x.x.x and 255.255.255.0). (See Appendix A) 2. Use a crossover cable, and plug into the switch or directly into the Altiga private port. 3. Using Internet Explorer, web into the Altiga by typing its IP address (10.x.x.11) in the Address box (where you usually type http://www). 4. Type the User Name as nocadmin, and call Buddy Lewis at 214-616-7987 for the password. 5. Click Administration. 6. Click Software Update. The following displays: Software Update Current Software Revision: Altiga Networks/VPN Concentrator Version 2.2 (Rel) Mar 21 2000 21:31:23 7. Verify that the current software revision is Version 2.2. If so, do not go any further. If not, continue on the “Upgrading the Operating System.” Upgrading the VPN Operating System If the operating system in not Version 2.2, upgrade it by following these steps: 1. Type in the name of the image file, phoenixc.bin, and click the Upload button. 2. Click OK. 3. Click the Click here to go to reboot options link. 4. Select Reboot in the Action field. Global_P2_V2.9 epicRealm Confidential 53 5. Select Save the active configuration at time of reboot in the Configuration field. 6. Select Now in the When to reboot/shutdown field. 7. Click Apply. 8. Log back in to the Altiga. 9. Verify the update was successful by clicking Administration, Software Update. 10. Click the Logout icon. 11. Close the browser. After the update is complete, reboot, and then double-check the version to be 2.2. Upgrading a Foundry Workgroup Switch 1. Connect your laptop to the console port of the Foundry Workgroup switch. 2. Start your HyperTerminal session. (See Appendix A) 3. Type enable. 4. Type show flash, and press the ENTER key to see what version of the operating system is running. There is a primary flash and a secondary flash, so check the OS on both. 5. If the OS is not at the appropriate level, then proceed with the upgrade. 6. From your HyperTerminal session, type show ip and press ENTER. 7. Verify that the IP address and subnet mask on your laptop is in the same subnet range as the Foundry switch. If not, configure your laptop with an IP address and subnet mask in the same range as the Foundry Workgroup Switch. (See Appendix A) 8. Connect your straight through patch cable to any port on the switch. 9. Start your TFTP server on your laptop. 10. Make sure you have the version of OS that you are installing in the TFTP default directory, so the switch can find it. You can get the IOS for the switch on //Vegas/Implementation Services/dbases/os-revs/. If you do not have network access, this file should be on diskette for you. If not, call Brian Hunter at 214-570-4404. 11. From your HyperTerminal session type copy tftp flash (tftp server ip address that you assigned to your laptop) (file name) primary, and press the enter key. 12. After the upgrade is complete, type reload. 13. Type Y to continue. 14. Type show flash to verify that the OS upgrade was successful. 54 epicRealm Confidential Global_P2_V2.9 15. Type end. 16. Type exit. Upgrading Cisco 2611 Access Routers/Terminal Servers Verifying the Operating System of the Cisco 2611 Access Router Check the IOS on the Cisco 2611 access router to make sure it is Version 12.0(9): 1. Plug the Cisco black or blue satin cable into the console port on the router. 2. Plug the other end of the console cable with a db9 connector into the laptop. 3. Plug the power cord into the router, and turn it on. 4. Bring up a HyperTerminal session. (See Appendix A) 5. Log into the router by typing enable, and pressing Enter. Then type the secret password (penguin). Type show version, and press Enter. 6. Look at the second line that says IOS, and check for software Version 12.0(9). If so, then stop here and do not go any further. If another version number displays, then turn on TFTP and continue with Upgrading the Cisco 2611 Operating System. Upgrading the Cisco 2611 Operating System 1. Connect a crossover cable from your laptop Ethernet to the Fast Ethernet 0/0 on the router. 2. Configure your laptop IP address to be in the same IP subnet as the router. (See Appendix A) 3. Open a HyperTerminal session (See Appendix A). 4. Open the TFTP Server, and load the correct file from //Vegas/Implementation Services/dbases/os-revs/. (Note: If you do not have network access, this should be provided for you on diskette. If not, call Brian Hunter at 214-570-4404.) 5. Type enable, and press Enter. 6. Type copy tftp flash, and press Enter. 7. Type the IP address of your laptop, and press Enter. Global_P2_V2.9 epicRealm Confidential 55 8. Type the following source file name: c2600-i-mz.120-9.bin, and press Enter. 9. Enter the destination file name, c2600-i-mz.120-9.bin, and press Enter. 10. When asked to erase flash, press Enter to accept the default Yes. 11. Press Enter to accept the default Confirm. 12. If the upgrade was successful, type reload, and press Enter. 13. Press Enter to accept the default Confirm. 14. Verify the new version by repeating Steps 5 and 6 under “Verifying the Operating System of the Cisco 2611 Access Router.” If you are not sure about the setup or have questions call Buddy Lewis at 214-6167987. Upgrading Cisco 3640 Routers Verifying the Operating System of the Cisco 3640 Router Check the IOS on the Cisco 3640 gateway router, and make sure it is Version 12.1(1)t. To verify the version number: 1. Plug the Cisco black or blue satin cable into the console port on the router. 2. Plug the other end of the console cable with a db9 connector into the laptop. 3. Plug the power cord into the router and turn it on. 4. Bring up a HyperTerminal session: (See Appendix A) 5. Log into the router. 6. Type enable, and press Enter. 7. At the Enter the Secret Password prompt, type penguin and press Enter. 8. Type show version, and press Enter. 9. Look at the second line that says IOS, and check for software Version 12.1(1)t. If it is correct, stop here and exit. If not, turn on TFTP and continue to “Upgrading the Cisco 3640 Operating System.” Upgrading the Cisco 3640 Operating System 1. Connect a crossover cable from your laptop Ethernet to the Fast Ethernet 0/0 on the router. 56 epicRealm Confidential Global_P2_V2.9 2. Configure your laptop IP address to be in the same IP subnet as the router. (See Appendix A) 3. Using HyperTerminal (See Appendix A), type enable, and press Enter. 4. Type copy tftp flash, and press Enter. 5. Type the address or name of the remote host, your laptop’s IP address, and press Enter. 6. Type the source file name, c3640-i-mz.121-1.T.bin. 7. Type the destination file name, c3640-i-mz.121-1.T.bin. 8. When asked to erase flash, press Enter to accept the default Yes. 9. If the upgrade is successful, type reload, and press Enter. 10. Press Enter to confirm. 11. Verify the new version by repeating Steps 5-9 under “Verifying the Operating System of the Cisco 3640 Router.” If you are not sure about the setup or have questions call Buddy Lewis at 214-6167987. Global_P2_V2.9 epicRealm Confidential 57 58 epicRealm Confidential Global_P2_V2.9 QA Checklist Installation Services Site ID: _________ PDUs powered on. Check dial-in capabilities to the data center. Dialup as if dialing up an ISP as you will connect via PPP. (Document POPS number) Verify connectivity to the Internet by pinging. Verify telnet connectivity to all devices and servers at the data center. Verify that all parameters are correct for this site. Make sure both IP addresses are working via Telnet. All cables installed and labeled per standard naming convention. All cables are tied down. Serial Numbers recorded and double-checked against packing list. Cleanup site including removal of packing material and boxes (very important). Collect all packing slips and return to Brian Hunter. Take digital photos of the data center, and email them to Brian Hunter at bhunter@epicrealm.com. Write the serial numbers of the equipment on the rack plans, and fax them to the NOC at 214-570-4821. Verify port layouts are accurate, sign and fax diagrams to the NOC at 214-570-4821. Inventory all remaining equipment left at the colo and it's location and return the list to the NOC at 214-570-4821. Return any remaining documentation and include a contact phone number of the person performing the installation. Signature of FSE ____________________________________________ Date ____________________ Global_P2_V2.9 epicRealm Confidential 59 60 epicRealm Confidential Global_P2_V2.9