Conductivity/Resistivity Meter

advertisement
■Sensor
(Unit: mm)
Our worldwide service network ensures speedy support,
when and where you need it.
●2-electrode sanitary conductivity sensor
■Flow-through sensor
FS-01 Series
■Connector cable
CK- ■M
■Insertion type sensor
ESH-01-C-S-SN-1.5S
Maintenance
space
50 or more
Maintenance
space
50 or more
Cable length: L
(ø6.5)
50
A
B
C
øD
A
2.5S
(140)
Model
82.5
(99.5) (103) (108.5) (114) (126.5)
55
85
110
65
75
Cable length
+5%
CK-Y10M
10 m 0
CK-Y20M
20 m +5%
0
CK-Y30M
30 m +5%
0
Japan
China
U.K.
HORIBA INSTRUMENTS
LIMITED
HORIBA TRADING (SHANGHAI) CO., Ltd.
HORIBA, Ltd.
HORIBA Advanced
Techno Co., Ltd.
HORIBA STEC
Co., Ltd.
HORIBA TECHNO
SERVICE Co., Ltd.
Shanghai Office
Beijing Office
ø17
(ø50.5)
●4-electrode sanitary conductivity sensor
10m
+5%
0
New Hampshire Office
Santa Clara Office
HORIBA Technology Center
10m
Austin Office
+5%
0
(105)
HORIBA STEC Co., Ltd., Aso Factory
35
Depending on
the coupling aperture of
the sanitary ferrule
Aperture 1.5S
ø29
øB
2.0S
2.5S
3.0S
4.0S
4.5S
øA
104
114
138
159
180
188
B
(80.5)
(86)
(98)
(109) (119.5) (123.5)
40
øA
73
(B)
)
( øA
Portland Office
(ø10)
Maintenance
space
100 or more
Maintenance
space
100 or more
Clamp-on gasket
(outside the scope
of Horiba delivery)
■Insertion type sensor
FES-210/220-L Series Cable-attached type
(ø10)
■Flow-through sensor
FES-310-L Series Cable-attached type
Aperture 1.5S
2.0S
øA
38.1
50.8
øB
50.5
64
(130)
Germany
France
■Flow-through sensor
FES-310-C Series Connector type
■Connector cable
SK- ■M
HORIBA FRANCE
SARL
■Insertion type sensor
FES-210/220-C Series Connector type
HORIBA EUROPE
GmbH
Singapore
Taiwan
HORIBA INSTRUMENTS
PTE. Ltd.
HORIBA, Ltd. TAIWAN
Representative Office
Korea
HORIBA
KOREA Ltd.
U.S.A.
HORIBA/STEC
INCORPORATED
Attach the SK series
connector cable.
Attach the SK series
connector cable.
50
(ø10)
Depending on the
coupling aperture of
the sanitary ferrule
øA
(91)
78
(B)
)
( øA
Maintenance
space
100 or more
Maintenance
space
100 or more
Cable length: L
Clamp-on gasket
(outside the scope
of Horiba delivery)
Model
35
ø21
Cable length
SK-Y10M
ø29
øB
+5%
10 m 0
+5%
0
SK-Y20M
20 m
SK-Y30M
30 m +5%
0
40
(130)
2.5S
3.0S
4.0S
4.5S
104
114
138
159
180
188
B
(80.5)
(86)
(98)
(109) (119.5) (123.5)
Maintenance
space
100 or more
■Socket insertion type
FES-240-L Cable-attached type
(ø10)
10m
+5%
0
FES-240-C Connector type
■VARIVENT® valve type
FES-230-L Cable-attached type
10m
(ø10)
Attach the SK
series connector
cable.
ø23.5
64
Please read the operation manual before using this product to assure safe and proper handling of the product.
● The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company.
● The color of the actual products may differ from the color pictured in this catalog due to printing limitations.
● It is strictly forbidden to copy the content of this catalog in part or in full.
http://www.horiba-adt.jp/index_e.htm
Head Office
31 Miyanonishicho, Kisshoin Minami-ku, Kyoto, Japan 601-8306
Phone: (81)75-321-7184 Fax: (81)75-321-7291
Attach the
SK series
connector
cable.
Tokyo Sales Office
Arule-Bldg, Higashikanda. 4th Fl, 1-7-8 Higashi-Kanda Chiyoda-ku, Tokyo, Japan 101-0031
Phone: (81)3-3851-3150 Fax: (81)3-3851-3140
Nagoya Sales Office
Sumitomoseimei Chigusa 2nd Bldg. 6th Fl, Aoi 3-15-31, Higashi-ku, Nagoya, Japan 461-0004
Phone: (81)52-937-0812 Fax: (81)52-937-0675
(ø84)
(91)
78
32 (17)
Socket
(outside the scope
of Horiba delivery)
50.5
ø38.1
(105)
78
32 (17)
ø34.2
50.8
øB
ø38.1
Keep at
least 12 mm
distance
from the
piping wall.
ø23.5
Socket
(outside the scope
of Horiba delivery)
16
16
(106)
73.5
43.5
ø34.2
(86)
73.5
43.5
ø44.2
ø41.8
38.1
+5%
0
(ø84)
ø44.2
ø41.8
2.0S
øA
FES-230-C Connector type
ø29
Tuhenhagen
DN40/50 plug
Keep at
least 12 mm
distance
from the
piping wall.
2.0S
øA
Maintenance
space
100 or more
Aperture 1.5S
Aperture 1.5S
Service Stations
●Kyoto: (81)75-321-7972 ●Tokyo: (81)3-3851-3150 ●Nagoya: (81)52-937-0812
ø29
Bulletin:HAE-S0141C
Tuhenhagen
DN40/50 plug
13
Industrial
Conductivity/Resistivity Meter
Sanitary
coupling
ferrule
1.5S
85
B
øD
1.0S 1.5S 2.0S
(120) (120) (120) (120)
55.5 59
70
64.5
131
(175)
C
ø21
Aperture 15A
Conductivity/Resistivity Meter
Selection Guide
& External Dimensions
Attach the
CK series
connector
cable.
Attach the CK series
connector cable.
Clamp-on packing
(outside the scope of
Horiba delivery)
Industrial
11
Printed in Japan
0902SK13
Industrial
Resistivity
Measurement principle
Conductivity
(SI unit)
Resistivity
The industrialtechnology and
Conductivity Meter and Resistivity Meter Lineups
0.01 µS/cm
0.0548
(1 µS/m)
100 MΩ·cm
2-electrode conductivity
0.1 µS/cm
1 µS/cm
10 µS/cm
(10 µS/m)
(100 µS/m)
(1000 µS/m)
1 MΩ·cm
10 MΩ·cm
18.24
Ultra pure water
Pure water
100 KΩ·cm
Distilled water
Rain water
Sample examples
Water for Injection
Resistivity
y meter
Conductivity meter (low concentration type)
■ 2-channel resistivity meter
Pure water
Ultra pure
water
Sterilized purified water, purified water
HE-960RW
■ Resistivity meter
HE-480R
P4
■ Conductivity meter
(low concentration type)
■ Conductivity meter
CE-200C
P4
HE-480C
P6
P6
(Rain-proof type)
Industrial
water
Distilling
plants
Conductivity
sensor
ESH-001
Resistivity sensor
ERF-001 Series
Conductivity
sensor
ESH-01
Measurement range: 0-20 µS/cm
Measurement range: 0-100.0 MΩ·cm
Measurement range: 0-200 µS/cm
* When used in conjunction with the CE-200C, measurement ranges expand to 10 µS/cm
■ Sanitary conductivity meter
(low concentration type)
HE-960CW
Pharmaceutical
processes
P7
Food and
beverage
processes
Flow-through sensor
FS-01 Series
Measurement range: 0-2000 µS/cm
■ Carbon sensor conductivity meter
■ Carbon sensor resistivity meter
HE-960RW-GC
Semiconductor
cleaning
processes
P5
P5
Carbon sensor
ERF-01-L-GC2
Measurement range: 0-100.0 MΩ·cm
2
HE-480C-GC
HE-960R-GC
P7
Carbon sensor
ESH-01-L-GC5
Measurement range: 0-200 µS/cm
Note: Measurement range listed in this document
grade conductivity meters and resistivity meters made by Horiba Advanced Techno are highly reliable products that pledge the high accuracy and high stability of creative sensing
a wealth of experience in diverse fields. Horiba Advanced Techno meets user needs with rich lineups for each and every type of application.
4-electrode conductivity
100 µS/cm
1000 µS/cm
10 mS/cm
100 mS/cm
(10 mS/m)
(100 mS/m)
(1000 mS/m)
(10 S/m)
10 KΩ·cm
1 KΩ·cm
100 Ω·cm
10 Ω·cm
Tap water
Boiler water
Salt water solution
Seawater
Beer, juice and
sports drinks
Mineral water
1000 mS/cm
(100 S/m)
1 Ω·cm
Inorganic acids, strong electrolytes
CIP: Cleaning-in-Place for chemicals
Conductivity
y meter (high
( g concentration type)
yp )
■ 2-channel conductivity meter
HE-960CW
■ Conductivity meter ■ Conductivity meter (high concentration type) ■ Conductivity meter (wide range type)
CEH-200
P7
HE-480H
P8
HE-960HS
P8
For details regarding
this product, please
contact us directly.
(Rain-proof type)
4-electrode
conductivity sensor
FES-125F
FES-126F
Conductivity
sensor
ESH-1
Measurement range: 0-2000 µS/cm
(ESH-001), 100 µS/cm (ESH-01) and 1000 µS/cm (ESH-1).
Measurement range: 0-500 mS/cm
* When used in conjunction with the CEH-200, measurement range expands to 20 mS/cm.
■ Sanitary conductivity meter (wide range type)
HE-960HI
P9
Insertion type sensor
ESH-01-C-S-SN-1.5S
Measurement range: 0-200 µS/cm
(low concentration type)
Flow-through sensor
FES-300 Series
Insertion type sensor
FES-200 Series
Measurement range: 0-500 mS/cm
■ Carbon sensor conductivity meter (wide range type)
HE-960HC
P9
Carbon sensor
ESH-1-L-GC9
Measurement range: 0-2000 µS/cm
Flow type carbon sensor
FES-510 Series
Measurement range: 0-1000 mS/cm
is the maximum measurement possible and may vary depending on the combination used, environment conditions, and setting.
3
Resistivity Meter
Resistivity meters
2-channel resistivity meter
Resistivity meter
HE-960RW
HE-480R
Panel
mount
DIN96
2 ch
● High-quality resistivity meter
● 2-channel simultaneous measurement
● Employs highly accurate, high-stability
temperature measurement circuits
● Built-in RS-485 communications output
● Measures ultra pure water at a
high degree of accuracy
● Implements advanced
temperature compensation
● Allows for setting of the reference
temperature to any value
HE-960RW
Model
Panel
mount
SLIM48
1 ch
HE-480R
Model
Measurement method Electrode type (2-electrode method)
Measurement method Electrode type (2-electrode method)
Sensor input
Sensor input
2-channel (cell constant: 0.01/cm)
Temperature sensor Resistance thermometer: 1000 Ω/0°C
Resistivity: 0 to 2.00, 0 to 20.00 MΩ·cm
Measurement
Resistivity: 0 to 0.200, 0 to 2.00, 0 to 20.00 MΩ·cm
Measurement
0 to 20.0, 0 to 200.0 kΩ·m
range
1-channel (cell constant: 0.01/cm)
Temperature sensor Resistance thermometer: 1000 Ω/0°C
0 to 2.00, 0 to 20.0, 0 to 200.0 kΩ·m
range
(Without temperature compensation, resistivity can be measured in 100.0 MΩ·cm and 1000 kΩ·m ranges.)
(Without temperature compensation, resistivity can be measured in 100.0 MΩ·cm and 1000 kΩ·m ranges.)
Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.)
Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.)
Reproducibility
±0.1% FS (equivalent input)
Reproducibility
±0.5% FS (equivalent input)
Linearity
±0.5% FS (equivalent input)
Linearity
±0.5% FS (equivalent input)
Transmission output No. of outputs: 2; 4 to 20 mA DC/0 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω
Transmission
No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω
Contact output
No. of outputs: 4 (R1, R2, R3, and R4)
output
Contact type: Relay contacts R1 to R3: SPST (1a); R4: SPDT (1c)
Contact output
No. of outputs: 2 (R1 and R2)
Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load)
Contact type: Relay contact SPDT (1c)
Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and
Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load)
Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and
maintenance. (R1 and R2, and R3 and R4 are for common use, respectively.)
maintenance.
Communication function RS-485 I/O
Calibration function Resistivity: Based on the specified compensation coefficient for the cell constant (parameter input)
Calibration
Resistivity: Based on the specified compensation coefficient for the cell constant (parameter input)
Temperature: Calibrated by comparing with the reference thermometer
function
Temperature: Calibrated by comparing with the reference thermometer
Temperature
Temperature compensation for impurities in ultra-pure water (Temperature characteristics of impurities are user-selectable.)
Temperature
Based on the temperature characteristics of ultra-pure water (reference temperature: 25°C)
compensation
Based on the temperature characteristics of NaCl (reference temperature: 5 to 95°C)
compensation
Based on the reference temperature and temperature coefficient user-defined (reference
Based on the user-defined temperature coefficient (reference temperature: 5 to 95°C; temperature coefficient: ±5%/°C)
temperature: 5 to 95°C; temperature coefficient: ±5%/°C)
Power requirements 100 to 240 V AC ±10%, maximum 15 VA
Power requirements 100 to 240 V AC ±10%, maximum 10 VA
Conforming standards CE marking, FCC regulations
Conforming standards CE marking, FCC regulations
Compatible sensors ERF-001 series resistivity sensor (cell constant: 0.01/cm)
Compatible sensors ERF-001 series resistivity sensor (cell constant: 0.01/cm)
For ultra-pure water
Resistivity sensor
Responds to minute changes in the measurement water temperature
Threaded type
Model
ERF-001 Series
Cell constant
Wetted
material
ERF-001
Approx. 0.01/cm
Electrode
Titanium
Body
PVDF
Packing
Pressure of fluid being measured
FKM
0 to 0.5 MPa
Temperature of fluid being measured
ERF-001-L-T
ERF-001-C-T
(Cable-attached type)
(Connector type)
0 to 80ºC
Installation
Threaded type; Thread diameter: R (PT) 3/4
Cable length
Cable-attached type: 10 m, Y terminal (standard); limit cable extensions to a max. 50 m
Connector type: 10 m (CK-10M), 20 m (CK-20M), 30 m (CK-30M)
Holder to be combined
Flow type holder EFA-30, EFA-30P, EFA-30S
Compatible converter
HE-480R, HE-960RW
For ordering, refer to the model code chart on page 14.
■ Accessories
Connector cable
CK-10M/20M/30M
Flow type holder
EFA-30 Series
Model
EFA-30
EFA-30P
Liquid end materials
PVC
PVDF
SUS316
Liquid pressure range
0 to 0.1 MPa
0 to 0.1 MPa
0 to 0.5 MPa
0 to 100ºC
0 to 100ºC
Liquid temperature range
Liquid flow rate
This cable is for connecting
a connector type sensor to
the indication converter.
EFA-30
EFA-30P
EFA-30S
(PVC)
(PVDF)
(SUS-316)
Connected pipe diameter
0 to 50ºC
EFA-30S
0 to 10 L/min
Inlet: Rc (PT) 1/2, Outlet: Rc (PT) 1/2
For ordering, refer to the model code chart on page 15.
4
Carbon sensor resistivity meters
2-channel resistivity meter
Carbon sensor resistivity meter
HE-960RW-GC
2 ch
For semiconductor wet cleaning
Panel
mount
DIN96
● Carbon sensor compatible
● High speed response
● Allows for setting of the reference
temperature to any value
● 24 V DC power supply
RoHS
RoHS
COMPLIANT
COMPLIANT
HE-960RW-GC
Measurement method Electrode type (2-electrode method)
2-channel (cell constant: 0.1/cm)
Temperature sensor Resistance thermometer: 1000 Ω/0°C
Resistivity: 0 to 2.00, 0 to 20.00 MΩ·cm
Resistivity: 0 to 0.200, 0 to 2.00, 0 to 20.00 MΩ·cm
Measurement
0 to 20.0, 0 to 200.0 kΩ·m
range
1-channel (cell constant: 0.1/cm)
Sensor input
Temperature sensor Resistance thermometer: 1000 Ω/0°C
Measurement
HE-960R-GC
Model
Measurement method Electrode type (2-electrode method)
Sensor input
For semiconductor wet cleaning
Panel
mount
DIN96
1 ch
● Carbon sensor compatible
● 2-channel simultaneous measurement
● High speed response
● Built-in array of temperature
compensation functions
● 24 V DC power supply
Model
HE-960R-GC
0 to 2.00, 0 to 20.0, 0 to 200.0 kΩ·m
range
(Without temperature compensation, resistivity can be measured in 100.0 MΩ·cm and 1000 kΩ·m ranges.)
(Without temperature compensation, resistivity can be measured in 100.0 MΩ·cm and 1000 kΩ·m ranges.)
Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.)
Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.)
Reproducibility
±0.5% FS (equivalent input)
Reproducibility
±0.5% FS (equivalent input)
Linearity
±0.5% FS (equivalent input)
Linearity
±0.5% FS (equivalent input)
Transmission output No. of outputs: 2; 4 to 20 mA DC/0 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω
Transmission
No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω
Contact output
No. of outputs: 4 (R1, R2, R3, and R4)
output
Contact type: Relay contacts R1 to R3: SPST (1a); R4: SPDT (1c)
Contact output
No. of outputs: 2 (R1 and R2)
Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load)
Contact type: Relay contact SPDT (1c)
Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and
Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load)
maintenance. (R1 and R2, and R3 and R4 are for common use, respectively.)
Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and
maintenance.
Communication function RS-485 I/O
Calibration function Resistivity: Based on the specified compensation coefficient for the cell constant (parameter input)
Calibration
Resistivity: Based on the specified compensation coefficient for the cell constant (parameter input)
Temperature: Calibrated by comparing with the reference thermometer
function
Temperature: Calibrated by comparing with the reference thermometer
Temperature
Temperature compensation for impurities in ultra-pure water (Temperature characteristics of impurities are user-selectable.)
Temperature
Based on the temperature characteristics of ultra-pure water (reference temperature: 25°C)
compensation
Based on the temperature characteristics of NaCl (reference temperature: 5 to 95°C)
compensation
Based on the reference temperature and temperature coefficient user-defined (reference
Based on the user-defined temperature coefficient (reference temperature: 5 to 95°C; temperature coefficient: ±5%/°C)
temperature: 5 to 95°C; temperature coefficient: ±5%/°C)
Power requirements 24 V DC, maximum 10 W
Power requirements 24 V DC, maximum 5 W
Conforming standards CE marking, FCC regulations
Conforming standards CE marking, FCC regulations
Compatible sensors ERF-01 carbon resistivity sensor (cell constant: 0.1/cm)
Compatible sensors ERF-01 carbon resistivity sensor (cell constant: 0.1/cm)
World’s first chemical-resistant
glass carbon sensor!
●Excellent chemical resistance
Leads are made of 100% carbon and therefore exhibit
excellent chemical resistance against all types of
cleaning fluids such as hydrogen fluoride and hydrogen
peroxide.
For semiconductor wet cleaning
Carbon resistivity sensor
Applicable to single-bach cleaning systems
Glass carbon sensor offers superior resistance to chemicals
Threaded type
Model
ERF-01-L-GC2
ERF-01-L-GC2
Cell constant
Approx. 0.1/cm
Wetted
material
●Metallic contamination-free
Electrode
Glass carbon
Body
PFA
Kalrez®
Packing
Pressure of fluid being measured
There is no need to worry about the metallic
contamination that was unavoidable with metal leads of
the past. The carbon surface has been specially treated
to minimize particle runoff.
0 to 0.05 MPa
Temperature of fluid being measured
Installation
0 to 80ºC
Threaded type; Thread diameter: R (PT) 3/4
Cable length
●High speed response
ERF-01-L-GC2
Cable-attached type
Due to the special treatment of the carbon surface,
response from chemicals and ultrapure water is the
same as earlier models.
10 m, Y terminal (standard)
Holder to be combined
Flow type holder EFA-30P, EFA-30F
Compatible converter
HE-960R-GC, HE-960RW-GC
For ordering, refer to the model code chart on page 14.
■ Accessories
Flow type holder
EFA-30 Series
Model
EFA-30P
Liquid end materials
Liquid pressure range
Liquid temperature range
Liquid flow rate
EFA-30P
(PVDF)
Connected pipe diameter
EFA-30F
PVDF
PFA
0 to 0.1 MPa
0 to 100ºC
0 to 10 L/min
Inlet: Rc (PT) 1/2, Outlet: Rc (PT) 1/2
*For flow type holder, use EFA-30P(PVDF) or EFA-30F(PFA) respectively.
For ordering, refer to the model code chart on page 15.
5
Conductivity Meter (low concentration type)
Conductivity meters (2-electrode type)
Conductivity meter (rain-proof type)
Conductivity meter (low concentration type)
CE-200C
HE-480C
1 ch
Low
concentration
type
Rain-proof
type
Low
concentration
type
Panel
mount
SLIM48
1 ch
● Perfect for continuous
measurement of ultra-pure water.
● Automatic determination of sensor
integrity
● Built-in temperature characteristics
for each type of solution
● Large custom LCD
● Simultaneous display of measured values and parameter settings
● Ideal for continuous measurement of pure
water and boiler water
● High precision temperature compensation
● Automatic determination of sensor integrity
● Supports a variety of temperature
compensation
Model
Model
CE-200C
HE-480C
Measurement method Electrode type (2-electrode method)
Measurement method Electrode type (2-electrode method)
Sensor input
Sensor input
1-channel (cell constant: 0.01/cm, 0.1/cm, 1.0/cm)
Temperature sensor Resistance thermometer: 1000 Ω/0°C
1-channel (cell constant: 0.01/cm, 0.1/cm, 1.0/cm)
Temperature sensor Resistance thermometer: 1000 Ω/0°C
Measurement
Cell constant (/cm)
0.01
0.1
1.0
range
Conductivity (µS/cm)
1.00
10.0
100.0
2.00
20.0
200
5.00
50.0
500
10.00
100.0
1000
Measurement
Cell constant (/cm)
range
Conductivity
0.01
0.1
1.0
(µS/cm)
2.000/20.00
20.00/200.0
200.0/2000
(mS/m)
0.2000/2.000
2.000/20.00
20.00/200.0
2.00/20.0
20.0/200
200/2000
TDS conversion (mg/L)
Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.)
Temperature: 0 to 100°C (measurement only)
Reproducibility
Reproducibility
±0.5% FS
Transmission output No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω
Transmission
No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; (Transmission output of temperature is
Contact output
output
not attached.) Maximum load resistance: 500 Ω
Contact type: Relay contact SPDT (1c)
Contact output
No. of outputs: 2
Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load)
Contact type: Relay contact SPDT (1c)
Contact function: Select between upper/lower limit operation (ON/OFF control), USP
±0.5% FS (TDS: ±1.5% FS)
No. of outputs: 2 (R1 and R2)
Contact rating: 250 V AC 3 A (resistance load)
determination, error alarm, and maintenance.
Contact function: Upper/lower limit operation (ON/OFF control)
Calibration
Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input)
Calibration
Conductivity: Depends upon the cell constant setting
function
Temperature: Calibrated by comparing with the reference thermometer
function
Temperature: One-point calibration at a known temperature
Temperature
Ultra-pure water (limited to 1.00 µS/cm at a cell constant of 0.01)
Temperature
Based on the temperature characteristics of ultra-pure water (reference temperature: 25°C)
compensation
NaCl (when the cell constant is 0.01, 0.1, or 1.0) 0 to ±5%/°C (custom setting possible)
compensation
Based on the reference temperature and temperature coefficient user-defined (reference temperature: 5 to 95°C; temperature coefficient: ±5%/°C)
TDS: Conversion using user-set coefficient (0.30 to 1.00)
Temperature characteristics of NaCl
Power requirements 100 to 115 V AC or 200 to 240 V AC (as ordered), 7 VA (max.)
Structure
Outdoor installation: JIS CO920; Protection level: 3 (rain-proof)
Power requirements 100 to 240 V AC ±10%, maximum 10 VA
Installation method: 50 A pole or wall attachment
Conforming standards CE marking, FCC regulations
Compatible sensors ESH series conductivity sensor (cell constant: 0.01/cm, 0.1/cm, 1.0/cm)
General-purpose
Compatible sensors ESH and FS series conductivity sensor (cell constant: 0.01/cm, 0.1/cm, 1.0/cm)
2-electrode method conductivity sensor
Model
Threaded type
Cell constant
ESH-001·01·1 Series
Wetted
material
ESH-001
ESH-01
ESH-1
Approx. 0.01/cm
Approx. 0.1/cm
Approx. 1.0/cm
Electrode
SUS-316 or Titanium
Body
PVDF
Packing
Pressure of fluid being measured
FKM
0 to 0.5 MPa
Temperature of fluid being measured
Flange mounting type
ESH-01
ESH-01
ESH-01
(Cable-attached type)
(Connector type)
(Connector type)
0 to 100ºC
Installation
Threaded type; Thread diameter: R (PT) 3/4
Cable length
Cable-attached type: 10 m, Y terminal (standard); limit cable extensions to a max. 100 m
Connector type: 10 m (CK-10M), 20 m (CK-20M), 30 m (CK-30M)
Holder to be combined
Flow type holder EFA-30, EFA-30P, EFA-30S
Compatible converter
CE-200C, HE-480C, HE-960CW
For ordering, refer to the model code chart on page 15.
■ Accessories
Relay box
CT-20EC
Sensor extension cable
C-5C
Connector cable
CK-10M/20M/30M
Flow type holder
EFA-30 Series
Model
Liquid end materials
Liquid pressure range
Liquid temperature range
Liquid flow rate
Used for connecting the
converter and the relay box.
This cable is for connecting
a connector type sensor to
the indication converter.
EFA-30
EFA-30S
(PVC)
(SUS-316)
Connected pipe diameter
EFA-30
EFA-30P
EFA-30S
PVC
PVDF
SUS316
0 to 0.1 MPa 0 to 0.1 MPa 0 to 0.5 MPa
0 to 50ºC
0 to 100ºC
0 to 100ºC
0 to 10 L/min
Inlet: Rc (PT) 1/2, Outlet: Rc (PT) 1/2
For ordering, refer to the model code chart on page 15.
6
Sanitary conductivity (2-electrode type)
Carbon sensor conductivity meter (2-electrode type)
2-channel conductivity meter (low concentration type)
Carbon sensor conductivity meter (low concentration type)
HE-960CW
HE-480C-GC
Panel
mount
DIN96
2 ch
Low
concentration
type
Panel
mount
SLIM48
1 ch
● High grade type suited for monitoring
of medical water quality
● 2-channel simultaenous measurement
and simultaneous output
● Built-in USP<645> water quality
evaluation function
● Built-in RS-485 communication output
For semiconductor wet cleaning
Low
concentration
type
● Carbon sensor compatible
● Wide measurement range
● Simultaneous display of measured values and
parameter settings
● Built-in array of temperature compensation
functions
RoHS
COMPLIANT
HE-960CW
Model
Model
Measurement method Electrode type (2-electrode method)
2-channel (cell constant: 0.01/cm, 0.1/cm, 1.0/cm)
Sensor input
Sensor input
Temperature sensor Resistance thermometer: 1000 Ω/0°C
Measurement
Cell constant (/cm)
range
Conductivity
HE-480C-GC
Measurement method Electrode type (2-electrode method)
1-channel (cell constant: 0.01/cm, 0.1/cm, 1.0/cm)
Temperature sensor Resistance thermometer: 1000 Ω/0°C
0.01
0.1
1.0
(µS/cm)
2.000/20.00
2.000/20.00/200.0/2000*
200.0/2000
(mS/m)
0.2000/2.000
0.2000/2.000/20.00/200.0*
20.00/200.0
Measurement
Cell constant (/cm)
range
Conductivity
*Only applicable for FS-01 series sanitary sensors.
1.0
20.00/200.0
200.0/2000
(mS/m)
0.2000/2.000
2.000/20.00
20.00/200.0
2.00/20.0
20.0/200
200/2000
When used in conjunction with the ESH-1-L-GC9, if the sensor is operated with temperature compensation unset or at a
±0.5% FS (TDS: ±1.5% FS)
temperature of 30°C or below, measurement is possible over a range of up to a maximum of 9999 µS/cm and 999.9 mS/m.
Transmission output No. of outputs: 4; 4 to 20 mA DC, 0 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω
Contact output
0.1
2.000/20.00
TDS conversion (mg/L)
Temperature: 0 to 100°C (1- or 2-digit selectable, whole numbers only)
Reproducibility
0.01
(µS/cm)
Reproducibility
±0.5% FS (TDS: ±1.5% FS)
No. of outputs: 4 (R1, R2, R3, and R4)
Transmission output No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω
Contact type: Relay contacts R1 to R3: SPST (1a); R4: SPDT (1c)
Contact output
No. of outputs: 2 (R1 and R2)
Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load)
Contact type: Relay contact SPST (1a)
Contact function: Select between upper/lower limit operation (ON/OFF control), UPS determination, error
Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load)
alarm, and maintenance. (R1 and R2, and R3 and R4 are for common use, respectively.)
Communication function RS-485 I/O
Contact function: Select between upper/lower limit operation (ON/OFF control), USP determination, error alarm, and maintenance.
Calibration
Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input)
function
Temperature: Calibrated by comparing with the reference thermometer
Calibration
Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input)
function
Temperature: Calibrated by comparing with the reference thermometer
Temperature
Based on the temperature characteristics of NaCl (reference temperature: 5 to 95°C)
Temperature
Based on the temperature characteristics of ultra-pure water (reference temperature: 25°C)
compensation
Based on the reference temperature and temperature coefficient user-defined (reference temperature: 5 to 95°C; temperature coefficient: ±5%/°C)
compensation
Based on the reference temperature and temperature coefficient user-defined (reference temperature: 5 to 95°C; temperature coefficient: ±5%/°C)
TDS: Conversion using user-set coefficient (0.30 to 1.00)
Temperature characteristics of NaCl
(Temperature compensation for pure water automatically engages in the pure water range.)
Power requirements 100 to 240 V AC ±10%, maximum 15 VA
Power requirements 100 to 240 V AC ±10%, maximum 10 VA
Conforming standards CE marking, FCC regulations
Conforming standards CE marking, FCC regulations
Compatible sensors ESH and FS series conductivity sensor (cell constant: 0.01/cm, 0.1/cm, 1.0/cm)
Compatible sensors ESH carbon conductivity sensor (cell constant: 0.1/cm, 1.0/cm)
For pharmaceutical / food processing
Sanitary conductivity sensor
Can also be used
Pharmaceutical / food processing type conductivity
sensor for applications that demand high sanitary levels with Steam-InPlace cleaning
Flow-through sensor
Insertion type sensor
FS-01 Series
ESH-01-C-S-SN
Parts contacting
fluids are straight
and without
projections.
FS-01F-C-SL-2.5S
For semiconductor wet cleaning
Carbon conductivity sensor
Electrodes made of highly chemical resistant glass carbon which allows
for measurement in a wide range of chemicals used in semiconductor
washing and other processes.
Threaded type
Threaded type
ESH-01-L-GC5
ESH-1-L-GC9
ESH-01-C-S-SN-1.5S
ESH-01-L-GC5-Y-10M
FS-01
(flow-through type)
Model
Cell constant
Wetted material
Protective structure
ESH-01-C-S-SN
(insert type)
Approx. 0.1/cm
SUS316L*, PTFE, FKM
Model
ESH-01-L-GC5
ESH-1-L-GC9
Cell constant
Approx. 0.1/cm
Approx. 0.7/cm
SUS316L*, PEEK, FKM
(Compliant with MHLW Bulletin No. 20 and 85)
IP67 equivalent
Wetted
material
Electrode
Body
Pressure of fluid being measured
0 to 1 MPa
Packing
Pressure of fluid being measured
Temperature of fluid being measured
0 to 100ºC
Temperature of fluid being measured
Steam sterilization
Connection aperture (ferrule)
Cable length
Compatible converter
140°C/0.6 MPa within 60 minutes
15A, 1S, 1.5S, 2S, 2.5S
1.5S
ESH-1-L-GC9-Y-10M
Glass carbon
PFA
Kalrez®
0 to 0.5 MPa
0 to 80ºC
Installation
Threaded type; Thread diameter: R (PT) 3/4
Cable length
10 m, Y terminal (standard); limit cable extensions to a max. 100 m
10m (CK-10M), 20m (CK-20M), 30m (CK-30M)
Holder to be combined
Flow type holder EFA-30P, EFA-30F
HE-960CW
Compatible converter
HE-480C-GC
* Cannot be used with fluids (hydrochloric acid, diluted sulfuric acid, seawater, etc.) that chemically react with electrode (SUS316L).
For ordering, refer to the model code chart on page 15.
For ordering, refer to the model code chart on page 15.
7
Conductivity Meter (high concentration type)
Conductivity meters (4-electrode type)
Conductivity meter (rain-proof type)
Conductivity meter (high concentration type)
CEH-200
HE-480H
1 ch
Rain-proof
type
Panel
mount
SLIM48
1 ch
● Employs five AC electrode sensors
● Automatic determination of sensor
integrity
● Can continuously measure salinity
and temperature of seawater
● Large custom LCD
High
concentration
type
● Wide range measurement possible to 500 mS/cm*1
● Equipped with a seawater salinity and NaCl salinity
conversion function
● Supports a variety of temperature compensation
● Automatic determination of sensor integrity
*1: For measurements over 200 mS/cm, wide range type
HE-960HS model is recommended. Contact the sales
for details.
Model
CEH-200
Sensor input
Measurement method Electrode type (4-electrode method)
1-channel (cell constant: 1.0/cm)
Temperature sensor Resistance thermometer: 1000 Ω/0°C
Conductivity: 1.00/2.00/5.00/10.0/20.0 mS/cm
Salinity:
Conductivity
Measurement
1000/2000/5000 µS/cm
range
1-channel (cell constant: 1.0/cm)
Sensor input
Temperature sensor Resistance thermometer: 1000 Ω/0°C
Measurement
HE-480H
Model
Measurement method Electrode type (4-electrode method)
range
(mS/cm)
0.00 to 20.00
0.0 to 200.0
0.0 to 500.0
(S/m)
0.000 to 2.000
0.00 to 20.00
0.00 to 50.00
0 to 4.0% (operating temperature: 0 to 40°C)
* Measurement in the 200.0 mS/cm and 20.00 S/m ranges is possible up to a custom temperature coefficient setting of ±3.5%/°C at a reference temperature of 25°C.
(Selectable with function setting switch)
* Measurement in the 500.0 mS/cm and 50.00 S/m ranges is possible without temperature compensation. *1
Temperature: 0 to 100°C (measurement only)
Seawater salinity conversion: 0.00 to 4.00%
Reproducibility
±0.5% FS (within ±1.0%FS at 1000 µS/cm)
NaCl salinity conversion: 0.0 to 20.0%
Transmission
No. of outputs: 1; 4 to 20 mA DC; I/O insulation type (Transmission output of temperature is
output
not attached.); maximum load resistance 500 Ω
Reproducibility
Contact output
No. of outputs: 2
Transmission output No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω
Contact type: Relay contact SPDT (1c)
Contact output
Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.)
±0.5% FS (±1.0% for salinity conversion and the 500 mS/cm range)
No. of outputs: 2 (R1 and R2)
Contact rating: 250 V AC 3 A (resistance load)
Contact type: Relay contact SPDT (1c)
Contact function: Upper/lower limit operation (ON/OFF control)
Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load)
Calibration
Conductivity, salinity: Depends upon the cell constant setting
function
Temperature: One-point calibration at a known temperature
Calibration
Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input)
Temperature
Based on the reference temperature and temperature coefficient user-defined (reference
function
Temperature: Calibrated by comparing with the reference thermometer
Temperature
Based on the reference temperature and temperature coefficient user-defined (reference
compensation
Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and maintenance.
temperature: 5 to 95°C; temperature coefficient: ±5%/°C)
Temperature characteristics of NaCl
compensation
Structure
temperature: 5 to 95°C; temperature coefficient: ±5%/°C)
Temperature characteristics of NaCl
Power requirements 100 to 115 V AC or 200 to 240 V AC (as ordered), 7 VA (max.)
Outdoor installation: JIS CO920; Protection level: 3 (rain-proof)
Power requirements 100 to 240 V AC ±10%, maximum 10 VA
Installation method: 50 A pole or wall attachment
Conforming standards CE marking, FCC regulations
Compatible sensors FES series conductivity sensor (cell constant: 1.0/cm)
General-purpose
Compatible sensors FES series conductivity sensor (cell constant: 1.0/cm)
4-electrode method conductivity sensor
Model
Cell constant
Electrode
Wetted
Body
material Packing
Pressure of fluid being measured
Temperature of fluid being measured
Submersible type/Threaded type
FES-100 Series
Cable length
Installation
FES-126F
FES-126FNi
(Submersible type)
(Threaded type)
Holder to be combined
Compatible converter
FES-126FNi (for TMAH)
FES-126F
Approx. 0.1/cm
Titanium
Nickel
Titanium
PPS
PPS
PVC
EPDM
FKM
FKM
0 to 0.5 MPa
0 to 0.5 MPa
0 to 0.5 MPa
0 to 120°C *1
0 to 120°C
0 to 50°C
10 m, Y terminal (standard); Use the CT-20EC relay box for further extension.
Maximum extension length: 50 m
1. Submersible type
1. Submersible type
Threaded type
2. Threaded type
2. Threaded type
Thread diameter: R (PT) 3/4
Use the thread
Use the thread
adapter EA-20.
adapter EA-40.
Flow type holder: EF-20, EF-20P, EF-20S
Flow type holder: EF-20P
CEH-200, HE-480H, HE-960HS
HE-960TM (for TMAH)
FES-125F
*1. Submersible types can only be used between 0 and 50°C
For ordering, refer to the model code chart on page 15.
■ Accessories
Relay box
CT-20EC
Sensor extension cable
C-7E
Connector cable
SK-10M/20M/30M
Flow type holder
EF-20 Series
Model
Used for connecting the
converter and the relay box.
This cable is for connecting
a connector type sensor to
the indication converter.
Liquid end materials
Liquid pressure range
Liquid temperature range
Liquid flow rate
Connected pipe diameter
EF-20
EF-20P
EF-20S
PVC
0 to 50ºC
0 to 0.1 MPa
PVDF
0 to 100ºC
0 to 0.1 MPa
SUS 316
0 to 100ºC
0 to 0.5 MPa
0 to 10 L/min
Inlet: Rc (PT) 1/2, Outlet: Rc (PT) 1/2
For ordering, refer to the model code chart on page 15.
8
Sanitary conductivity meter (4-electrode type)
Carbon sensor conductivity meter (4-electrode type)
Sanitary conductivity meter (wide range type) For pharmaceutical / food processing
Carbon sensor conductivity meter (wide range type)
HE-960HI
HE-960HC
Wide
range
type
Panel
mount
DIN96
1 ch
For Cleaning-in-Place (CIP) terminal management
● Measures the full range up to 500
mS/cm
● Automatic display range switching
● Equipped with nitric acid(HNO3),
phosphoric acid(H3PO4), and sodium
hydroxide (NaOH) concentration
automatic conversion function
● Built-in RS-485 communications output
Model
Panel
mount
DIN96
1 ch
For semiconductor wet cleaning
Wide
range
type
● Carbon sensor compatible
● Measures the full range up to
1000 mS/cm
● Automatic display range switching
● Equipped with the chemical
concentration conversion function
● Built-in RS-485
RoHS
communications output
COMPLIANT
Model
HE-960HI
HE-960HC
Measurement method Electrode type (4-electrode method)
Measurement method Electrode type (4-electrode method)
Sensor input
Sensor input
1-channel (cell constant: 0.1/cm)
1-channel (cell constant: 0.1/cm)
Temperature sensor Resistance thermometer: 1000 Ω/0°C
Temperature sensor Resistance thermometer: 1000 Ω/0°C
Measurement
Conductivity: 0 to 200 mS/cm (Conductivity measurement range prior to temperature compensation: 0 to 500 mS/cm)
Measurement
Conductivity: 0 to 1000 mS/cm (Conductivity measurement range prior to temperature compensation)
range
Temperature: 0 to 100°C
range
Temperature: 20 to 150°C
Concentration
NaOH: 0 to 5%, HNO3: 0 to 5%, H3PO4: 0 to 5% (using internal program)
Concentration conversion Custom 1: 0 to 100%, Custom 2: 0 to 100% (user-customizable conversion formula)
conversion
Custom 1: 0 to 100%, Custom 2: 0 to 100% (user-customizable conversion formula)
Reproducibility
Reproducibility
±0.5% FS (within ±1.0%FS at 500 mS/cm ranges)
Transmission output No. of outputs: 4; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω
Contact output
0 to 20.00 mS/cm
20.0 to 200.0 mS/cm
(equivalent input)
200 to 1000 mS/cm
No. of outputs: 5 (R1, R2, R3, R4, and RF)
Within ±1.0%FS
Transmission output No. of outputs: 4; 4 to 20 mA DC/0 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω
Contact type: Relay contacts R1 to R4: SPST (1a); RF: SPDT (1c)
Contact output
No. of outputs: 5 (R1, R2, R3, R4, and RF)
Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load)
Contact type: Relay contacts R1 to R4: SPST (1a); RF: SPDT (1c)
Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and
Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load)
Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and
maintenance. (R1 and R2·R3, and R4 and RF are for common use,
maintenance. (R1 and R2·R3, and R4 and RF are for common use,
respectively.)
Contact Input
Within ±0.5%FS
respectively.)
No. of inputs: 2
Contact function: Interchangeable transmission output range, External input for holding
Contact Input
Communications function RS-485 I/O
No. of input: 1
Contact function: Transmission output for holding
Calibration
Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input)
Communications function RS-485 I/O
function
Temperature: Calibrated by comparing with the reference thermometer
Calibration
Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input)
Temperature
Based on the reference temperature and temperature coefficient user-defined (reference temperature: 25°C; temperature coefficient: 0 to 5%/°C)
function
Temperature: Calibrated by comparing with the reference thermometer
compensation
Based on the temperature characteristics of NaCl (reference temperature: 25°C)
Temperature compensation Based on the reference temperature and temperature coefficient user-defined (reference temperature: 25°C; temperature coefficient: 0 to 3%/°C)
Power requirements 100 to 240 V AC ±10%, maximum 20 VA
Power requirements 100 to 240 V AC ±10%, maximum 20 VA
Conforming standards CE marking, FCC regulations
Conforming standards CE marking, FCC regulations
Compatible sensors FES-300 and FES-200 series conductivity sensor (cell constant: 0.1/cm)
Compatible sensors FES-510 carbon conductivity sensor (cell constant: 1.0/cm)
For pharmaceutical / food processing
Sanitary conductivity sensor
For semiconductor wet cleaning
Carbon conductivity sensor
Can also be used
Pharmaceutical / food processing type conductivity
sensor for applications that demand high sanitary levels with Steam-InPlace cleaning
Electrodes made of highly chemical resistant glass carbon which allows for measurement
in a wide range of chemicals used in semiconductor washing and other processes.
Flow-through sensor
Insertion type sensor
Flow type carbon sensor
FES-300 Series
FES-200 Series
FES-510 Series
Parts contacting
fluids are straight
and without
projections.
FES-310-L-S-SN-3.0S
FES-310
(flow-through type)
Model
Cell constant
Wetted material
Protective structure
FES-510-3/4
FES-210-L-S-SN-2.0S
FES-210, 220, 230, 240
(insert type)
Approx. 0.1/cm
SUS316L*, PPS, FKM (Compliant with MHLW Bulletin No. 20 and 85)
IP67 equivalent
Model
FES-510
Cell constant
Wetted
material
Electrode
Body
Pressure of fluid being measured
0 to 1 MPa
Packing
Pressure of fluid being measured
Temperature of fluid being measured
0 to 110ºC
Temperature of fluid being measured
Steam sterilization
Connection aperture (ferrule)
Cable length
Compatible converter
140°C/0.6 MPa within 60 minutes
1.5S, 2.0S, 2.5S, 3.0S, 4.0S, 4.5S 1.5S, 2.0S, VARIVENT® valve, Socket attachment type
Cable-attached type: 10 m, Y terminal (standard); limit cable extensions to a max. 50 m
Connector type: 10 m (SK-10M), 20 m (SK-20M), 30 m (SK-30M)
Liquid flow rate
Cable length
HE-960HI
* Cannot be used with fluids (hydrochloric acid, diluted sulfuric acid, seawater, etc.) that chemically react with electrode (SUS316L).
For ordering, refer to the model code chart on page 15.
Compatible converter
Approx. 1.0/cm
Glass carbon
PFA
Kalrez®
0 to 0.5 MPa (Within 5 to 50)
5 to 100ºC
0 to 2 L/min (1/4 in), 0 to 8 L/min (3/8 in)
0 to 10 L/min (1/2 in), 0 to 15 L/min (3/4 in)
0 to 25 L/min (1 in)
Cable-attached type: 10 m, ring terminal (standard);
limit cableextensions to a max. 50 m
HE-960HC
For ordering, refer to the model code chart on page 15.
9
External Dimensions
■Indication converter
(Unit: mm)
Resistivity meter / Conductivity meter
●Panel mount type
48 Series
Panel cutting dimensions
115
48
92 +0.8
0
130
96
(Min.)
45 +0.6
0
70
(Min.)
●Panel mount type
96 Series
96
Panel cutting dimensions
115
92 0
+0.8
(Min.)
96
130
+0.8
92 0
118
(Min.)
●Rain-proof type
200 Series
230
50
180
100
70
220
180
40
20
260
155
35
35
35
60
35
ø60.5
210
222
(50A pole)
*Sold separately
Diagram shown here is an example of
a pole attachment.
Wall installation also available.
■Sensor
●Resistivity sensor
●Carbon resistivity sensor
ERF-01-L-GC2
ERF-001 Series
Cable-attached type
●Connector cable
CK-■M
(ø6.5)
Connector type
Cable length: L
(ø6.5)
Waterproof connector
+5%
0
35
Required fluid level
(ø13.8)
10
(ø13.8)
(ø16)
50
ø26
ø32
10
R3/4
25 20
115.5
R 3/4
Across flats 29
55
(7)
ø32
20 35.5
Required fluid level
+5%
0
(ø6.5)
115.5
R 3/4
Across flats 29
25
Required fluid level
25
ø32
115.5
Across flats 29
20 35.5
ø26
10m
ø26
50
10m
ø21
Model
Cable length
+5%
CK-Y10M
10 m 0
CK-Y20M
20 m +5%
0
CK-Y30M
30 m +5%
0
■Sensor
(Unit: mm)
Our worldwide service network ensures speedy support,
when and where you need it.
●2-electrode sanitary conductivity sensor
■Flow-through sensor
FS-01 Series
■Connector cable
CK- ■M
■Insertion type sensor
ESH-01-C-S-SN-1.5S
Maintenance
space
50 or more
Maintenance
space
50 or more
Cable length: L
(ø6.5)
50
A
B
C
øD
A
2.5S
(140)
Model
82.5
(99.5) (103) (108.5) (114) (126.5)
55
85
110
65
75
Cable length
+5%
CK-Y10M
10 m 0
CK-Y20M
20 m +5%
0
CK-Y30M
30 m +5%
0
Japan
China
U.K.
HORIBA INSTRUMENTS
LIMITED
HORIBA TRADING (SHANGHAI) CO., Ltd.
HORIBA, Ltd.
HORIBA Advanced
Techno Co., Ltd.
HORIBA STEC
Co., Ltd.
HORIBA TECHNO
SERVICE Co., Ltd.
Shanghai Office
Beijing Office
ø17
(ø50.5)
●4-electrode sanitary conductivity sensor
10m
+5%
0
New Hampshire Office
Santa Clara Office
HORIBA Technology Center
10m
Austin Office
+5%
0
(105)
HORIBA STEC Co., Ltd., Aso Factory
35
Depending on
the coupling aperture of
the sanitary ferrule
Aperture 1.5S
ø29
øB
2.0S
2.5S
3.0S
4.0S
4.5S
øA
104
114
138
159
180
188
B
(80.5)
(86)
(98)
(109) (119.5) (123.5)
40
øA
73
(B)
)
( øA
Portland Office
(ø10)
Maintenance
space
100 or more
Maintenance
space
100 or more
Clamp-on gasket
(outside the scope
of Horiba delivery)
■Insertion type sensor
FES-210/220-L Series Cable-attached type
(ø10)
■Flow-through sensor
FES-310-L Series Cable-attached type
Aperture 1.5S
2.0S
øA
38.1
50.8
øB
50.5
64
(130)
Germany
France
■Flow-through sensor
FES-310-C Series Connector type
■Connector cable
SK- ■M
HORIBA FRANCE
SARL
■Insertion type sensor
FES-210/220-C Series Connector type
HORIBA EUROPE
GmbH
Singapore
Taiwan
HORIBA INSTRUMENTS
PTE. Ltd.
HORIBA, Ltd. TAIWAN
Representative Office
Korea
HORIBA
KOREA Ltd.
U.S.A.
HORIBA/STEC
INCORPORATED
Attach the SK series
connector cable.
Attach the SK series
connector cable.
50
(ø10)
Depending on the
coupling aperture of
the sanitary ferrule
øA
(91)
78
(B)
)
( øA
Maintenance
space
100 or more
Maintenance
space
100 or more
Cable length: L
Clamp-on gasket
(outside the scope
of Horiba delivery)
Model
35
ø21
Cable length
SK-Y10M
ø29
øB
+5%
10 m 0
+5%
0
SK-Y20M
20 m
SK-Y30M
30 m +5%
0
40
(130)
2.5S
3.0S
4.0S
4.5S
104
114
138
159
180
188
B
(80.5)
(86)
(98)
(109) (119.5) (123.5)
Maintenance
space
100 or more
■Socket insertion type
FES-240-L Cable-attached type
(ø10)
10m
+5%
0
FES-240-C Connector type
■VARIVENT® valve type
FES-230-L Cable-attached type
10m
(ø10)
Attach the SK
series connector
cable.
ø23.5
64
Please read the operation manual before using this product to assure safe and proper handling of the product.
● The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company.
● The color of the actual products may differ from the color pictured in this catalog due to printing limitations.
● It is strictly forbidden to copy the content of this catalog in part or in full.
http://www.horiba-adt.jp/index_e.htm
Head Office
31 Miyanonishicho, Kisshoin Minami-ku, Kyoto, Japan 601-8306
Phone: (81)75-321-7184 Fax: (81)75-321-7291
Attach the
SK series
connector
cable.
Tokyo Sales Office
Arule-Bldg, Higashikanda. 4th Fl, 1-7-8 Higashi-Kanda Chiyoda-ku, Tokyo, Japan 101-0031
Phone: (81)3-3851-3150 Fax: (81)3-3851-3140
Nagoya Sales Office
Sumitomoseimei Chigusa 2nd Bldg. 6th Fl, Aoi 3-15-31, Higashi-ku, Nagoya, Japan 461-0004
Phone: (81)52-937-0812 Fax: (81)52-937-0675
(ø84)
(91)
78
32 (17)
Socket
(outside the scope
of Horiba delivery)
50.5
ø38.1
(105)
78
32 (17)
ø34.2
50.8
øB
ø38.1
Keep at
least 12 mm
distance
from the
piping wall.
ø23.5
Socket
(outside the scope
of Horiba delivery)
16
16
(106)
73.5
43.5
ø34.2
(86)
73.5
43.5
ø44.2
ø41.8
38.1
+5%
0
(ø84)
ø44.2
ø41.8
2.0S
øA
FES-230-C Connector type
ø29
Tuhenhagen
DN40/50 plug
Keep at
least 12 mm
distance
from the
piping wall.
2.0S
øA
Maintenance
space
100 or more
Aperture 1.5S
Aperture 1.5S
Service Stations
●Kyoto: (81)75-321-7972 ●Tokyo: (81)3-3851-3150 ●Nagoya: (81)52-937-0812
ø29
Bulletin:HAE-S0141C
Tuhenhagen
DN40/50 plug
13
Industrial
Conductivity/Resistivity Meter
Sanitary
coupling
ferrule
1.5S
85
B
øD
1.0S 1.5S 2.0S
(120) (120) (120) (120)
55.5 59
70
64.5
131
(175)
C
ø21
Aperture 15A
Conductivity/Resistivity Meter
Selection Guide
& External Dimensions
Attach the
CK series
connector
cable.
Attach the CK series
connector cable.
Clamp-on packing
(outside the scope of
Horiba delivery)
Industrial
11
Printed in Japan
0902SK13
(Unit: mm)
●2-electrode conductivity sensor
ERF-001 Series
For flange mounting
Cable-attached type
Connector type
Cable-attached type
(ø6.5)
Waterproof connector
øA
øA
øA
ESH-1
16
ESH-01
13.8
R 3/4
Required
fluid level
165.5
ø22
ø32
75
20 35.5
R 3/4
Required
fluid level
Model
Across flats 29
165.5
R 3/4
ø32
75
115.5
25
R 3/4
20 35.5
(7)
Required
fluid level
ø26
Across flats 29
ø32
ø26
20 35.5
ø26
50
Across flats 29
115.5
ø32
25
Required
fluid level
20 35.5
ø26
+5%
0
50
10m
+5%
0
(7)
Waterproof connector
10m
Across flats 29
Connector type
(ø6.5)
ø22
ESH-001 13.8
øA
●2-electrode carbon conductivity sensor
CK-■M
ESH-1-L-GC9
(ø6.5)
ø26
10m
ø26
+5%
0
●Flow type holder
●Connector cable
EFA-30 Series
Measurement fluid outlet
Rc 3/4
Cable length: L
(ø6.5)
ESH-01-L-GC5
øA
10m
+5%
0
ø34
(ø6.5)
Required fluid level
ø18
Measurement
fluid inlet
Rc 3/4
ø21
Across flats
29 ø32
Model
ø18
●4-electrode conductivity sensor
Sensor
attachment
Rc 3/4
100
Cable length
+5%
0
CK-Y10M
10 m
CK-Y20M
20 m +5%
0
CK-Y30M
30 m +5%
0
●Flow type holder
FES-125F/FES-126F
●Relay box
EF-20/EF-20S
CT-20EC
Measurement fluid outlet
Rc 1/2
With threaded type adapter
ø99.5
Cable length 10 m
Cable length 10 m
ø40
35
R3/4
15.5
50
43
Across flats
29 ø32
50
(78)
Required fluid level
22.5 20 10 (25.5)
20 10 (26)
R3/4
1
2
T
T
E
1
2
T
T
E
(106)
25
ø34
35
Measurement
fluid inlet
Rc 1/2
ø28
238
Sensor
attachment
Rc 3/4
220
70
■93
70
R(PT)3/4
98
ø20
Measurement fluid outlet
Rc 1/2
EF-20P
(193)
126.5
4-ø10
(50)
ø35
Measurement
fluid inlet
Rc 1/2
ø50
ø20
71.5
35
50
(193)
Required fluid level
98
161.5
Required fluid level
For 25 A to 50 A pipes
*Sold separately
Sensor
attachment
Rc 3/4
220
122
ø36
50
(ø10)
ø24
ø60
(ø10)
●4-electrode carbon conductivity sensor
FES-510-1/2
13.5
(ø7)
70
2-ø7
(76.5)
50
4-Electrode Carbon Sensor
FES-510
63
42
(142.5)
10
(76.5)
90
(20)
10 m +5%
0
(375)
(142.5)
(54.5)
2-ø7
10
4-Electrode Carbon Sensor
FES-510
50
(142.5)
90
(20)
(142.5)
63
42
10 m +5%
0
(375)
(57.5)
FES-510-3/4
13.5
(ø7)
70
12
■Sensor
(Unit: mm)
Our worldwide service network ensures speedy support,
when and where you need it.
●2-electrode sanitary conductivity sensor
■Flow-through sensor
FS-01 Series
■Connector cable
CK- ■M
■Insertion type sensor
ESH-01-C-S-SN-1.5S
Maintenance
space
50 or more
Maintenance
space
50 or more
Cable length: L
(ø6.5)
50
A
B
C
øD
A
2.5S
(140)
Model
82.5
(99.5) (103) (108.5) (114) (126.5)
55
85
110
65
75
Cable length
+5%
CK-Y10M
10 m 0
CK-Y20M
20 m +5%
0
CK-Y30M
30 m +5%
0
Japan
China
U.K.
HORIBA INSTRUMENTS
LIMITED
HORIBA TRADING (SHANGHAI) CO., Ltd.
HORIBA, Ltd.
HORIBA Advanced
Techno Co., Ltd.
HORIBA STEC
Co., Ltd.
HORIBA TECHNO
SERVICE Co., Ltd.
Shanghai Office
Beijing Office
ø17
(ø50.5)
●4-electrode sanitary conductivity sensor
10m
+5%
0
New Hampshire Office
Santa Clara Office
HORIBA Technology Center
10m
Austin Office
+5%
0
(105)
HORIBA STEC Co., Ltd., Aso Factory
35
Depending on
the coupling aperture of
the sanitary ferrule
Aperture 1.5S
ø29
øB
2.0S
2.5S
3.0S
4.0S
4.5S
øA
104
114
138
159
180
188
B
(80.5)
(86)
(98)
(109) (119.5) (123.5)
40
øA
73
(B)
)
( øA
Portland Office
(ø10)
Maintenance
space
100 or more
Maintenance
space
100 or more
Clamp-on gasket
(outside the scope
of Horiba delivery)
■Insertion type sensor
FES-210/220-L Series Cable-attached type
(ø10)
■Flow-through sensor
FES-310-L Series Cable-attached type
Aperture 1.5S
2.0S
øA
38.1
50.8
øB
50.5
64
(130)
Germany
France
■Flow-through sensor
FES-310-C Series Connector type
■Connector cable
SK- ■M
HORIBA FRANCE
SARL
■Insertion type sensor
FES-210/220-C Series Connector type
HORIBA EUROPE
GmbH
Singapore
Taiwan
HORIBA INSTRUMENTS
PTE. Ltd.
HORIBA, Ltd. TAIWAN
Representative Office
Korea
HORIBA
KOREA Ltd.
U.S.A.
HORIBA/STEC
INCORPORATED
Attach the SK series
connector cable.
Attach the SK series
connector cable.
50
(ø10)
Depending on the
coupling aperture of
the sanitary ferrule
øA
(91)
78
(B)
)
( øA
Maintenance
space
100 or more
Maintenance
space
100 or more
Cable length: L
Clamp-on gasket
(outside the scope
of Horiba delivery)
Model
35
ø21
Cable length
SK-Y10M
ø29
øB
+5%
10 m 0
+5%
0
SK-Y20M
20 m
SK-Y30M
30 m +5%
0
40
(130)
2.5S
3.0S
4.0S
4.5S
104
114
138
159
180
188
B
(80.5)
(86)
(98)
(109) (119.5) (123.5)
Maintenance
space
100 or more
■Socket insertion type
FES-240-L Cable-attached type
(ø10)
10m
+5%
0
FES-240-C Connector type
■VARIVENT® valve type
FES-230-L Cable-attached type
10m
(ø10)
Attach the SK
series connector
cable.
ø23.5
64
Please read the operation manual before using this product to assure safe and proper handling of the product.
● The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company.
● The color of the actual products may differ from the color pictured in this catalog due to printing limitations.
● It is strictly forbidden to copy the content of this catalog in part or in full.
http://www.horiba-adt.jp/index_e.htm
Head Office
31 Miyanonishicho, Kisshoin Minami-ku, Kyoto, Japan 601-8306
Phone: (81)75-321-7184 Fax: (81)75-321-7291
Attach the
SK series
connector
cable.
Tokyo Sales Office
Arule-Bldg, Higashikanda. 4th Fl, 1-7-8 Higashi-Kanda Chiyoda-ku, Tokyo, Japan 101-0031
Phone: (81)3-3851-3150 Fax: (81)3-3851-3140
Nagoya Sales Office
Sumitomoseimei Chigusa 2nd Bldg. 6th Fl, Aoi 3-15-31, Higashi-ku, Nagoya, Japan 461-0004
Phone: (81)52-937-0812 Fax: (81)52-937-0675
(ø84)
(91)
78
32 (17)
Socket
(outside the scope
of Horiba delivery)
50.5
ø38.1
(105)
78
32 (17)
ø34.2
50.8
øB
ø38.1
Keep at
least 12 mm
distance
from the
piping wall.
ø23.5
Socket
(outside the scope
of Horiba delivery)
16
16
(106)
73.5
43.5
ø34.2
(86)
73.5
43.5
ø44.2
ø41.8
38.1
+5%
0
(ø84)
ø44.2
ø41.8
2.0S
øA
FES-230-C Connector type
ø29
Tuhenhagen
DN40/50 plug
Keep at
least 12 mm
distance
from the
piping wall.
2.0S
øA
Maintenance
space
100 or more
Aperture 1.5S
Aperture 1.5S
Service Stations
●Kyoto: (81)75-321-7972 ●Tokyo: (81)3-3851-3150 ●Nagoya: (81)52-937-0812
ø29
Bulletin:HAE-S0141C
Tuhenhagen
DN40/50 plug
13
Industrial
Conductivity/Resistivity Meter
Sanitary
coupling
ferrule
1.5S
85
B
øD
1.0S 1.5S 2.0S
(120) (120) (120) (120)
55.5 59
70
64.5
131
(175)
C
ø21
Aperture 15A
Conductivity/Resistivity Meter
Selection Guide
& External Dimensions
Attach the
CK series
connector
cable.
Attach the CK series
connector cable.
Clamp-on packing
(outside the scope of
Horiba delivery)
Industrial
11
Printed in Japan
0902SK13
(100 µS/m)
(1000 µS/m)
Cable-attached type
Connector type
Cable-attached type
(ø6.5)
Sterilized purified water, purified water
R 3/4
R 3/4
Required
fluid level
Model
Conductivity meter (low concentration type)
CE-200C
HE-480C
●2-electrode carbon conductivity sensor
P6
P6
ø26
10m
(Rain-proof type)
22.5 20 10 (25.5)
Required fluid level
15.5
Across flats
29 ø32
R3/4
ø18
■ Sanitary conductivity meter
(low concentration type)
Measurement
fluid inlet
Rc 3/4
Model
CK-Y10M
ø18
●4-electrode conductivity sensor
CK-Y20M
20 m
CK-Y30M
30 m +5%
0
●Relay box
ø99.5
Measurement
fluid inlet
Rc 1/2
Conductivity meter
(4-electrode method)
Sensor
attachment
Rc 3/4
220
70
ø20
Measurement range: 0-100.0 MΩ·cm
Carbon sensor
ESH-01-L-GC5
Measurement range: 0-200 µS/cm
Note: Measurement range listed in this document
2-channel resistivity meter
2 ch
Ring terminal (option)
N/A
When the connector type sensor is selected
Connector type*2
-C
Electrode: SUS 316L, Electorde insulation: PEEK
-S
Sanitary type (Structure: compliant with IP67)
-SN
-1.5S
Cell constant Connection
Model
Material
Conductivity sensor (2-electrode method)
Cell constant: 0.1/cm
-01F
Connector type*2
-C
Electrode: SUS 316, Electorde insulation: PEEK
-SL
-15A
IFD/ISO 15 ferrule
-XX
Designed cable length (option)*1
-1S
IFD/ISO 1S ferrule
N/A
When the connector type sensor is selected
-1.5S
IFD/ISO 1.5S ferrule
-2S
IFD/ISO 2S ferrule
-2.5S
IFD/ISO 2.5S ferrule
ø50
71.5
2-ø7
10
4-Electrode Carbon Sensor
FES-510
(142.5)
50
90
(ø7)
63
42
(20)
(142.5)
Cell length Terminal type Cable length
Panel mount
1 ch
Rain-proof
type
RoHS
-Y
Y terminal (standard)
-O
Ring terminal (option)
-10M
10 m (standard)
-XX
Designed cable length (option)*1
1 ch
COMPLIANT
-L
Carbon sensor conductivity meter (low concentration type)
1 ch
Panel mount
Panel mount
DIN96
■ CEH-200
Conductivity meter (rain-proof type)
■ HE-480H
Conductivity meter (high concentration type)
Sanitary conductivity meter (wide range type)
DIN96
DIN96
Resitivity sensor
(ø7)
12
Model
-L
Cable-attached type
-C
Connector type*3
Cell constant Connection Material
Temperature
testing Terminal type Cable length
RoHS
-N
-N
No temperature testing (standard)
-R
-R
With 0ºC temperature testing (option)
-Y
With pair calibration*1
-O
With 0ºC temperature testing (option)
-O
Ring terminal (option)
-XX
Designated cable length (option) *2
When the connector type sensor is selected
When the connector type sensor is selected
*1 The sensor and converter are calibrated together before shipping. Contact your sales representative separately.
Calibration accuracy (HE-960RW+ERF-001 sensor)
Resistivity
Within ±0.01 MΩ·cm
Temperature
Within ±0.02ºC
Size
In-line flow type
-510
Piping size: 3/8 in. (substandard)
Electrode: Nickel; Packing; EPDM (option)
-1/2
Piping size: 1/2 in. (substandard)
Threaded type adaptor required separately*4
-3/4
Piping size: 3/4 in. (standard)
-1
Piping size: 1 in. (substandard)
-6_4
Piping size: ø6/ø4 mm
-10_8
Piping size: ø10/ø8 mm
Specifications
Connection Electrode material Structure
Model
-L
-L
Cable-attached type*1
-C
-C
Connector type*2
In-line flow-through type
-310
Cable-attached type*1
Connector type*2
SUS316L, PPS, FKM
-S
SUS316L, PPS, FKM
Connection Electrode material Structure
Specifications
4-electrode conductivity sensor
Insertion type (Ferrule attachment material: SUS)
-S
Size
FES
Sanitary type (Structure: IP67 equivalent)
-SN
Sanitary type (Structure: IP67 equivalent)
-1.5S
IFD/ISO 1.5S ferrule
-1.5S
IFD/ISO 1.5S ferrule
-2.0S
IFD/ISO 2.0S ferrule
-2.0S
IFD/ISO 2.0S ferrule
-2.5S
IFD/ISO 2.5S ferrule
-3.0S
IFD/ISO 3.0S ferrule
-4.0S
IFD/ISO 4.0S ferrule
-4.5S
IFD/ISO 4.5S ferrule
Size
Specifications
4-electrode conductivity sensor
FES
Insertion type (VARIVENT® valve attachment
-230
-L
Cable-attached type*1
-C
Connector type*2
SS316L, PPS, FKM
-DN50
VARIVENT® valve
Accessories
Flow type holder (For 4-electrode conductivity sensor)
EF-20 Series (Compatible sensor: FES Series)
Model
-20
Insertion type (Socket attachment)
-L
Cable-attached type
-C
Connector type
Cell constant Connection
EF
Socket attachment type
Specifications
Product name
Model
Flow type holder
CT-20EC Relay box
For 4-electrode method
C-7E
Exclusive-use extension cable
(for 4-electrode conductivity sensors)
SK-10M
Connecter cable 10 m
(for 4-electrode conductivity sensors)
N/A
PVC
-P
PVDF
-S
SUS-316
Threaded type adaptor
Against reference device/
At same temperature
*2 Limit cable extensions to a max. 50 m. (Relay boxes cannot be used.)
*3 A connector cable (CK-10M/20M/30M, etc.) is separately required for connector type sensors.
*4 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed.
*5 Use a flow type holder (EFA-31P/31F) sold separately, if needed.
Size
Made by order
[Flow-through type]
Insertion type (Ferrule attachment material: resin)
-240
Specifications
4-electrode conductivity sensor
-Ni
-S
N/A
N/A
Model
FES
-220
Ring terminal (option)
10 m (standard)
Designated cable length (option) *2
FES-510 Series (Compatible converter: HE-960HC)
[Flow type]
-210
Y terminal (standard)
-10
10 m (standard)
Specifications
4-electrode conductivity sensor
Model
Y terminal (standard)
-10
■Carbon conductivity sensor (For semi-conductor and FPD manufacturing)
[Custom insertion type]
-Y
-XX
Connecter cable 30 m
(for 2-electrode conductivity sensors)
Piping size: 1/4 in. (standard)
Specifications
No temperature testing (standard)
Titanium*4
CK-30M
-3/8
-SN
Electrode: Glass carbon; Body: PFA*5
-GC2
Connecter cable 20 m
(for 2-electrode conductivity sensors)
Made by order
Electrode: Titanium; Packing: FKM (standard)
Connection Electrode material Structure
Model
Cable-attached type
-L
CK-20M
PFA
N/A
FES
COMPLIANT
Cell constant 0.1/cm
-01
Connecter cable 10 m
(for 2-electrode conductivity sensors)
F
-1/4
Resistivity sensor
ERF
Cell constant 0.01/cm
(-S)
70
Specifications
Designed cable length (option)*1
FES-200/300 Series (Compatible converter: HE-960HI)
[Insertion type]
ERF-01 Series (Compatible converters: HE-960RW-GC, HE-960R-GC)
Temperature
testing Terminal type Cable length
Connecter cable 5 m
(for 2-electrode conductivity sensors)
CK-10M
SUS-316
■Sanitary conductivity sensor (For food and pharmaceutical manufacturing)
ERF-001 Series (Compatible converters: HE-960RW, HE-480R)
Electrode
material
CK-5M
PVDF
-S
Cable-attached type*1
N/A
Wide range
type
Panel mount
1 ch
Carbon sensor conductivity meter (wide range type)
Exclusive-use extension cable
(for 2-electrode conductivity sensors)
-P
Submersible type (Body: PPS)
N/A
Wide range
type
Panel mount
1 ch
10 m (standard)
Submersible type (Body: PVC)
Wide range
type
DIN96
C-5C
PVC
*1 Limit cable extensions to max. 100 m. Relay box usage is recommended for cable extensions exceeding 30 m.
*2 Separate connector cable (CK-10M/20M/30M etc.) required for connector type sensors.
*3 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed.
*4 Use a flow type holder (EFA-31P/31F) sold separately, if needed.
4-electrode conductivity sensor
High concentration type
Panel mount
-10M
-XX
Connection Electrode material Connection
-125F
SLIM48
1 ch
Conductivity meter (wide range type)
-T
13.5
Ring terminal (option)
FES-100 Series (Compatible converter: CEH-200, HE-480H, HE-960HS)
■Carbon resistivity sensor (For semi-conductor and FPD manufacturing)
Cell constant Connection
Y terminal (standard)
-O
FES
Panel mount
1 ch
For 2-electrode method
N/A
*4
-Y
■4-electrode conductivity sensor (General-purpose)
RoHS
COMPLIANT
Rain-proof
type
1 ch
Relay box
4-electrode conductivity sensor FES series
Low concentration type
SLIM48
Product name
Model
CT-20EC
Electrode: glass carbon, Body: PFA
N/A
Low concentration type
-30
Specifications
Flow type holder
Cable-attached type
Low concentration type
SLIM48
Cell constant Connection
EFA
Cell constant: 1/cm
-1
Low concentration type
Panel mount
Model
*4
COMPLIANT
DIN96
Accessories
Flow type holder (For resistivity sensors and 2-electrode conductivity sensors)
EFA-30 Series (Compatible sensors: ERF, ESH Series)
Electrode: glass carbon, Body: PP
N/A
DIN96
Specifications
Electrode: glass carbon, Body: PFA
RoHS
Specifications
Size
FS
10 m (standard)
-GC6
Panel mount
IFD/ISO 1.5S ferrule
-10
Cable-attached type
SLIM48
■Resistivity sensor (For ultra-pure water)
Model
(375)
13.5
Y terminal (standard)
Cell constant 0.1/cm
Panel mount
1 ch
■ HE-480C-GC
-001
(76.5)
50
(20)
2-ø7
10
4-Electrode Carbon Sensor
FES-510
70
2
1 ch
2 channel conductivity meter (low concentration type)
ERF
63
42
(142.5)
90
10 m +5%
0
P7
For 25 A to 50 A pipes
*Sold separately
FES-510-1/2
(142.5)
Carbon sensor
ERF-01-L-GC2
Resistivity meter
■ HE-960CW
■ HE-960HC
●4-electrode carbon conductivity sensor
(375)
-Y
-O
-L
DIN96
Resistivity sensor ERF series
Sensor
attachment
Rc 3/4
220
FES-510-3/4
For flange mounting
Conductivity sensor (2-electrode method)
Panel mount
2 ch
2 ch
■ HE-960HI
(50)
50
Measurement
fluid inlet
Rc 1/2
10 m +5%
0
HE-480C-GC
-LG
ESH
Conductivity meter (low concentration type)
■ HE-960HS
4-ø10
35
ø20
For flow type holder*3
-126F
ø35
(54.5)
■
Measurement fluid outlet
Rc 1/2
EF-20P
(193)
126.5
98
98
(193)
161.5
Required fluid level
Cell constant: 0.1/cm
-01
(Compatible converter: HE-480C-GC)
Cell constant Connection Material
Specifications
Conductivity sensor (2-electrode method)
[Flow-through type] (Compatible converters: HE-480C, HE-960CW)
Titanium
-ST
EFA-30
Model
50
ø36
Measurement range: 0-2000 µS/cm
■ Carbon sensor conductivity meter
+
ø34
ø60
ø24
Required fluid level
Flow-through sensor
FS-01 Series
ERF-001-C-T-S-Y-10M
CT-20EC
R(PT)3/4
P5
+
HE-960RW
Conductivity meter (rain-proof type)
■ HE-480C
Measurement fluid outlet
Rc 1/2
ø28
P5
EFA-30
Carbon sensor resistivity meter
■ CE-200C
Conductivity meter
(2-electrode method)
+5%
0
●Flow type holder
P7
Semiconductor
cleaning
processes
+
•Material: PVC
Size
Structure
SUS-316
-GC9
35
Pharmaceutical
processes
HE-960R-GC
■ HE-960R-GC
+5%
HE-960CW
HE-960RW-GC
CK-10M
2-channel resistivity meter
■ HE-480R
10 m 0
Cable length 10 m
(ø10)
Connector type*2
100
With threaded type adapter
(ø10)
-C
-GC5
Sensor
attachment
Rc 3/4
Cable length
EF-20/EF-20S
Cable length 10 m
Cable-attached type
-01
ø34
ø21
Across flats
29 ø32
FES-125F/FES-126F
■ Carbon sensor resistivity meter
•Cell constant 0.01/cm
•Cable attached type
•Electrode material: Titanium
•Pair calibration
•Cable: 10m, Y termial
•Material: PVC
Product name
■ HE-960RW-GC
Measurement range: 0-200 µS/cm
* When used in conjunction with the CE-200C, measurement ranges expand to 10 µS/cm
Food and
beverage
processes
+
■ HE-960RW
Resistivity meter
Measurement fluid outlet
Rc 3/4
(ø6.5)
Required fluid level
-L
Flow type holder
Resistivity sensor
Model
(76.5)
Measurement range: 0-20 µS/cm
Measurement range: 0-100.0 MΩ·cm
(78)
(106)
Conductivity
sensor
ESH-01
R3/4
50
43
Conductivity
sensor
ESH-001
Resistivity sensor
ERF-001 Series
+5%
0
1
2
T
T
E
Distilling
plants
•10 m
•Y terminal
Model
EFA-30 Series
Cable length: L
10m
Cell constant 0.01/cm
-T
2-channel resistivity meter
Flow type holder
25
1
2
T
T
E
Industrial
water
ø26
+5%
0
-001
-S
Conductivity/Resistivity indication converter
øA
CK-■M
(ø6.5)
(ø6.5)
P4
ESH-01-C-T-ST
●Flow type holder
●Connector cable
ESH-1-L-GC9
Cell constant 0.1/cm
Cell constant Connection Material
■Carbon conductivity sensor (For semi-conductors and FPD manufacturing)
øA
ESH-01-L-GC5
P4
13.8
238
HE-480R
ESH-01
+
122
HE-960RW
■ Conductivity meter
ø22
Connector cable
ESH
Cell constant 1.0/cm
Sensor (connector type)
ESH-001 13.8
20 10 (26)
Pure water
Ultra pure
water
■ Resistivity meter
øA
16
2-electrode
conductivity sensor
•Cell constant 0.1/cm
•Connector type
•Electrode material: Titanium
•For dedicated holder
HE-480C
ESH-1
Connector cable
Relay box (option)
Model
Conductivity sensor (2-electrode method)
-01
(Example 2)
Conductivity
(low concentration type)
R 3/4
Required
fluid level
øA
Extension cable (option)
[Insertion type] (Compatible converters: HE-480C, HE-960CW)
Specifications
-1
Holder attachment (option)
(Example 1)
ø32
■Sanitary conductivity sensor (For food and pharmaceutical manufacturing)
Cell constant Connection Electrode material Cell length Terminal type Cable length
ESH
Sensor (cable-attached type)
Relay box (option)
Indication converter
ø26
(57.5)
■ 2-channel resistivity meter
■ Conductivity meter
(low concentration type)
øA
ø22
50
Resistivity
y meter
R 3/4
Extension cable (option)
70
■93
Water for Injection
Required
fluid level
Across flats 29
20 35.5
Required
fluid level
ø32
75
Rain water
Across flats 29
ø32
+5%
0
ø26
115.5
Distilled water
Across flats 29
25
Pure water
25
Ultra pure water
Sample examples
ø32
115.5
Across flats 29
ø26
(7)
ø26
20 35.5
100 KΩ·cm
20 35.5
1 MΩ·cm
10 MΩ·cm
18.24
Communications
output
Waterproof connector
10m
+5%
0
50
10m
100 MΩ·cm
Transmission
output
Connector type
(ø6.5)
Waterproof connector
Resistivity
Model
For flange mounting
165.5
(10 µS/m)
ERF-001 Series
20 35.5
10 µS/cm
50
1 µS/cm
2-electrode conductivity sensor ESH, FS series
■2-electrode conductivity sensor (General-purpose)
(Compatible converters: CE-200C, HE-480C, HE-960CW)
[Standard assembly]
(7)
0.0548
(1 µS/m)
0.1 µS/cm
(Unit: mm)
●2-electrode conductivity sensor
ø40
35
(SI unit)
0.01 µS/cm
2-electrode conductivity
Industrial Selection Guide for Conductivity Meter/Resistivity Meter
75
Resistivity
Measurement principle
Conductivity
The industrialtechnology and
Conductivity Meter and Resistivity Meter Lineups
165.5
Industrial
*1 For cable extensions, use relay box CT-20EC and limit extension to a max. of 50 m.
*2 Separate connector cable (SK-10M etc.) required for connector type sensors.
*3 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed.
*4 Separate threaded type adaptors EA-20 (for FES-125 sensors) and EA-40 (for FES-126 sensors) required.
14
Model
Product name
EA-20
Threaded type adaptor (for FES-125 sensor); Material: PVC
EA-40
Threaded type adaptor (for FES-126 sensor); Material: PVDF
The contents of this catalogue describe a standard specifications and codes. For custom specification according to your special needs, please contact our sales department.
15
(100 µS/m)
(1000 µS/m)
Cable-attached type
Connector type
Cable-attached type
(ø6.5)
Sterilized purified water, purified water
R 3/4
R 3/4
Required
fluid level
Model
Conductivity meter (low concentration type)
CE-200C
HE-480C
●2-electrode carbon conductivity sensor
P6
P6
ø26
10m
(Rain-proof type)
22.5 20 10 (25.5)
Required fluid level
15.5
Across flats
29 ø32
R3/4
ø18
■ Sanitary conductivity meter
(low concentration type)
Measurement
fluid inlet
Rc 3/4
Model
CK-Y10M
ø18
●4-electrode conductivity sensor
CK-Y20M
20 m
CK-Y30M
30 m +5%
0
●Relay box
ø99.5
Measurement
fluid inlet
Rc 1/2
Conductivity meter
(4-electrode method)
Sensor
attachment
Rc 3/4
220
70
ø20
Measurement range: 0-100.0 MΩ·cm
Carbon sensor
ESH-01-L-GC5
Measurement range: 0-200 µS/cm
Note: Measurement range listed in this document
2-channel resistivity meter
2 ch
Ring terminal (option)
N/A
When the connector type sensor is selected
Connector type*2
-C
Electrode: SUS 316L, Electorde insulation: PEEK
-S
Sanitary type (Structure: compliant with IP67)
-SN
-1.5S
Cell constant Connection
Model
Material
Conductivity sensor (2-electrode method)
Cell constant: 0.1/cm
-01F
Connector type*2
-C
Electrode: SUS 316, Electorde insulation: PEEK
-SL
-15A
IFD/ISO 15 ferrule
-XX
Designed cable length (option)*1
-1S
IFD/ISO 1S ferrule
N/A
When the connector type sensor is selected
-1.5S
IFD/ISO 1.5S ferrule
-2S
IFD/ISO 2S ferrule
-2.5S
IFD/ISO 2.5S ferrule
ø50
71.5
2-ø7
10
4-Electrode Carbon Sensor
FES-510
(142.5)
50
90
(ø7)
63
42
(20)
(142.5)
Cell length Terminal type Cable length
Panel mount
1 ch
Rain-proof
type
RoHS
-Y
Y terminal (standard)
-O
Ring terminal (option)
-10M
10 m (standard)
-XX
Designed cable length (option)*1
1 ch
COMPLIANT
-L
Carbon sensor conductivity meter (low concentration type)
1 ch
Panel mount
Panel mount
DIN96
■ CEH-200
Conductivity meter (rain-proof type)
■ HE-480H
Conductivity meter (high concentration type)
Sanitary conductivity meter (wide range type)
DIN96
DIN96
Resitivity sensor
(ø7)
12
Model
-L
Cable-attached type
-C
Connector type*3
Cell constant Connection Material
Temperature
testing Terminal type Cable length
RoHS
-N
-N
No temperature testing (standard)
-R
-R
With 0ºC temperature testing (option)
-Y
With pair calibration*1
-O
With 0ºC temperature testing (option)
-O
Ring terminal (option)
-XX
Designated cable length (option) *2
When the connector type sensor is selected
When the connector type sensor is selected
*1 The sensor and converter are calibrated together before shipping. Contact your sales representative separately.
Calibration accuracy (HE-960RW+ERF-001 sensor)
Resistivity
Within ±0.01 MΩ·cm
Temperature
Within ±0.02ºC
Size
In-line flow type
-510
Piping size: 3/8 in. (substandard)
Electrode: Nickel; Packing; EPDM (option)
-1/2
Piping size: 1/2 in. (substandard)
Threaded type adaptor required separately*4
-3/4
Piping size: 3/4 in. (standard)
-1
Piping size: 1 in. (substandard)
-6_4
Piping size: ø6/ø4 mm
-10_8
Piping size: ø10/ø8 mm
Specifications
Connection Electrode material Structure
Model
-L
-L
Cable-attached type*1
-C
-C
Connector type*2
In-line flow-through type
-310
Cable-attached type*1
Connector type*2
SUS316L, PPS, FKM
-S
SUS316L, PPS, FKM
Connection Electrode material Structure
Specifications
4-electrode conductivity sensor
Insertion type (Ferrule attachment material: SUS)
-S
Size
FES
Sanitary type (Structure: IP67 equivalent)
-SN
Sanitary type (Structure: IP67 equivalent)
-1.5S
IFD/ISO 1.5S ferrule
-1.5S
IFD/ISO 1.5S ferrule
-2.0S
IFD/ISO 2.0S ferrule
-2.0S
IFD/ISO 2.0S ferrule
-2.5S
IFD/ISO 2.5S ferrule
-3.0S
IFD/ISO 3.0S ferrule
-4.0S
IFD/ISO 4.0S ferrule
-4.5S
IFD/ISO 4.5S ferrule
Size
Specifications
4-electrode conductivity sensor
FES
Insertion type (VARIVENT® valve attachment
-230
-L
Cable-attached type*1
-C
Connector type*2
SS316L, PPS, FKM
-DN50
VARIVENT® valve
Accessories
Flow type holder (For 4-electrode conductivity sensor)
EF-20 Series (Compatible sensor: FES Series)
Model
-20
Insertion type (Socket attachment)
-L
Cable-attached type
-C
Connector type
Cell constant Connection
EF
Socket attachment type
Specifications
Product name
Model
Flow type holder
CT-20EC Relay box
For 4-electrode method
C-7E
Exclusive-use extension cable
(for 4-electrode conductivity sensors)
SK-10M
Connecter cable 10 m
(for 4-electrode conductivity sensors)
N/A
PVC
-P
PVDF
-S
SUS-316
Threaded type adaptor
Against reference device/
At same temperature
*2 Limit cable extensions to a max. 50 m. (Relay boxes cannot be used.)
*3 A connector cable (CK-10M/20M/30M, etc.) is separately required for connector type sensors.
*4 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed.
*5 Use a flow type holder (EFA-31P/31F) sold separately, if needed.
Size
Made by order
[Flow-through type]
Insertion type (Ferrule attachment material: resin)
-240
Specifications
4-electrode conductivity sensor
-Ni
-S
N/A
N/A
Model
FES
-220
Ring terminal (option)
10 m (standard)
Designated cable length (option) *2
FES-510 Series (Compatible converter: HE-960HC)
[Flow type]
-210
Y terminal (standard)
-10
10 m (standard)
Specifications
4-electrode conductivity sensor
Model
Y terminal (standard)
-10
■Carbon conductivity sensor (For semi-conductor and FPD manufacturing)
[Custom insertion type]
-Y
-XX
Connecter cable 30 m
(for 2-electrode conductivity sensors)
Piping size: 1/4 in. (standard)
Specifications
No temperature testing (standard)
Titanium*4
CK-30M
-3/8
-SN
Electrode: Glass carbon; Body: PFA*5
-GC2
Connecter cable 20 m
(for 2-electrode conductivity sensors)
Made by order
Electrode: Titanium; Packing: FKM (standard)
Connection Electrode material Structure
Model
Cable-attached type
-L
CK-20M
PFA
N/A
FES
COMPLIANT
Cell constant 0.1/cm
-01
Connecter cable 10 m
(for 2-electrode conductivity sensors)
F
-1/4
Resistivity sensor
ERF
Cell constant 0.01/cm
(-S)
70
Specifications
Designed cable length (option)*1
FES-200/300 Series (Compatible converter: HE-960HI)
[Insertion type]
ERF-01 Series (Compatible converters: HE-960RW-GC, HE-960R-GC)
Temperature
testing Terminal type Cable length
Connecter cable 5 m
(for 2-electrode conductivity sensors)
CK-10M
SUS-316
■Sanitary conductivity sensor (For food and pharmaceutical manufacturing)
ERF-001 Series (Compatible converters: HE-960RW, HE-480R)
Electrode
material
CK-5M
PVDF
-S
Cable-attached type*1
N/A
Wide range
type
Panel mount
1 ch
Carbon sensor conductivity meter (wide range type)
Exclusive-use extension cable
(for 2-electrode conductivity sensors)
-P
Submersible type (Body: PPS)
N/A
Wide range
type
Panel mount
1 ch
10 m (standard)
Submersible type (Body: PVC)
Wide range
type
DIN96
C-5C
PVC
*1 Limit cable extensions to max. 100 m. Relay box usage is recommended for cable extensions exceeding 30 m.
*2 Separate connector cable (CK-10M/20M/30M etc.) required for connector type sensors.
*3 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed.
*4 Use a flow type holder (EFA-31P/31F) sold separately, if needed.
4-electrode conductivity sensor
High concentration type
Panel mount
-10M
-XX
Connection Electrode material Connection
-125F
SLIM48
1 ch
Conductivity meter (wide range type)
-T
13.5
Ring terminal (option)
FES-100 Series (Compatible converter: CEH-200, HE-480H, HE-960HS)
■Carbon resistivity sensor (For semi-conductor and FPD manufacturing)
Cell constant Connection
Y terminal (standard)
-O
FES
Panel mount
1 ch
For 2-electrode method
N/A
*4
-Y
■4-electrode conductivity sensor (General-purpose)
RoHS
COMPLIANT
Rain-proof
type
1 ch
Relay box
4-electrode conductivity sensor FES series
Low concentration type
SLIM48
Product name
Model
CT-20EC
Electrode: glass carbon, Body: PFA
N/A
Low concentration type
-30
Specifications
Flow type holder
Cable-attached type
Low concentration type
SLIM48
Cell constant Connection
EFA
Cell constant: 1/cm
-1
Low concentration type
Panel mount
Model
*4
COMPLIANT
DIN96
Accessories
Flow type holder (For resistivity sensors and 2-electrode conductivity sensors)
EFA-30 Series (Compatible sensors: ERF, ESH Series)
Electrode: glass carbon, Body: PP
N/A
DIN96
Specifications
Electrode: glass carbon, Body: PFA
RoHS
Specifications
Size
FS
10 m (standard)
-GC6
Panel mount
IFD/ISO 1.5S ferrule
-10
Cable-attached type
SLIM48
■Resistivity sensor (For ultra-pure water)
Model
(375)
13.5
Y terminal (standard)
Cell constant 0.1/cm
Panel mount
1 ch
■ HE-480C-GC
-001
(76.5)
50
(20)
2-ø7
10
4-Electrode Carbon Sensor
FES-510
70
2
1 ch
2 channel conductivity meter (low concentration type)
ERF
63
42
(142.5)
90
10 m +5%
0
P7
For 25 A to 50 A pipes
*Sold separately
FES-510-1/2
(142.5)
Carbon sensor
ERF-01-L-GC2
Resistivity meter
■ HE-960CW
■ HE-960HC
●4-electrode carbon conductivity sensor
(375)
-Y
-O
-L
DIN96
Resistivity sensor ERF series
Sensor
attachment
Rc 3/4
220
FES-510-3/4
For flange mounting
Conductivity sensor (2-electrode method)
Panel mount
2 ch
2 ch
■ HE-960HI
(50)
50
Measurement
fluid inlet
Rc 1/2
10 m +5%
0
HE-480C-GC
-LG
ESH
Conductivity meter (low concentration type)
■ HE-960HS
4-ø10
35
ø20
For flow type holder*3
-126F
ø35
(54.5)
■
Measurement fluid outlet
Rc 1/2
EF-20P
(193)
126.5
98
98
(193)
161.5
Required fluid level
Cell constant: 0.1/cm
-01
(Compatible converter: HE-480C-GC)
Cell constant Connection Material
Specifications
Conductivity sensor (2-electrode method)
[Flow-through type] (Compatible converters: HE-480C, HE-960CW)
Titanium
-ST
EFA-30
Model
50
ø36
Measurement range: 0-2000 µS/cm
■ Carbon sensor conductivity meter
+
ø34
ø60
ø24
Required fluid level
Flow-through sensor
FS-01 Series
ERF-001-C-T-S-Y-10M
CT-20EC
R(PT)3/4
P5
+
HE-960RW
Conductivity meter (rain-proof type)
■ HE-480C
Measurement fluid outlet
Rc 1/2
ø28
P5
EFA-30
Carbon sensor resistivity meter
■ CE-200C
Conductivity meter
(2-electrode method)
+5%
0
●Flow type holder
P7
Semiconductor
cleaning
processes
+
•Material: PVC
Size
Structure
SUS-316
-GC9
35
Pharmaceutical
processes
HE-960R-GC
■ HE-960R-GC
+5%
HE-960CW
HE-960RW-GC
CK-10M
2-channel resistivity meter
■ HE-480R
10 m 0
Cable length 10 m
(ø10)
Connector type*2
100
With threaded type adapter
(ø10)
-C
-GC5
Sensor
attachment
Rc 3/4
Cable length
EF-20/EF-20S
Cable length 10 m
Cable-attached type
-01
ø34
ø21
Across flats
29 ø32
FES-125F/FES-126F
■ Carbon sensor resistivity meter
•Cell constant 0.01/cm
•Cable attached type
•Electrode material: Titanium
•Pair calibration
•Cable: 10m, Y termial
•Material: PVC
Product name
■ HE-960RW-GC
Measurement range: 0-200 µS/cm
* When used in conjunction with the CE-200C, measurement ranges expand to 10 µS/cm
Food and
beverage
processes
+
■ HE-960RW
Resistivity meter
Measurement fluid outlet
Rc 3/4
(ø6.5)
Required fluid level
-L
Flow type holder
Resistivity sensor
Model
(76.5)
Measurement range: 0-20 µS/cm
Measurement range: 0-100.0 MΩ·cm
(78)
(106)
Conductivity
sensor
ESH-01
R3/4
50
43
Conductivity
sensor
ESH-001
Resistivity sensor
ERF-001 Series
+5%
0
1
2
T
T
E
Distilling
plants
•10 m
•Y terminal
Model
EFA-30 Series
Cable length: L
10m
Cell constant 0.01/cm
-T
2-channel resistivity meter
Flow type holder
25
1
2
T
T
E
Industrial
water
ø26
+5%
0
-001
-S
Conductivity/Resistivity indication converter
øA
CK-■M
(ø6.5)
(ø6.5)
P4
ESH-01-C-T-ST
●Flow type holder
●Connector cable
ESH-1-L-GC9
Cell constant 0.1/cm
Cell constant Connection Material
■Carbon conductivity sensor (For semi-conductors and FPD manufacturing)
øA
ESH-01-L-GC5
P4
13.8
238
HE-480R
ESH-01
+
122
HE-960RW
■ Conductivity meter
ø22
Connector cable
ESH
Cell constant 1.0/cm
Sensor (connector type)
ESH-001 13.8
20 10 (26)
Pure water
Ultra pure
water
■ Resistivity meter
øA
16
2-electrode
conductivity sensor
•Cell constant 0.1/cm
•Connector type
•Electrode material: Titanium
•For dedicated holder
HE-480C
ESH-1
Connector cable
Relay box (option)
Model
Conductivity sensor (2-electrode method)
-01
(Example 2)
Conductivity
(low concentration type)
R 3/4
Required
fluid level
øA
Extension cable (option)
[Insertion type] (Compatible converters: HE-480C, HE-960CW)
Specifications
-1
Holder attachment (option)
(Example 1)
ø32
■Sanitary conductivity sensor (For food and pharmaceutical manufacturing)
Cell constant Connection Electrode material Cell length Terminal type Cable length
ESH
Sensor (cable-attached type)
Relay box (option)
Indication converter
ø26
(57.5)
■ 2-channel resistivity meter
■ Conductivity meter
(low concentration type)
øA
ø22
50
Resistivity
y meter
R 3/4
Extension cable (option)
70
■93
Water for Injection
Required
fluid level
Across flats 29
20 35.5
Required
fluid level
ø32
75
Rain water
Across flats 29
ø32
+5%
0
ø26
115.5
Distilled water
Across flats 29
25
Pure water
25
Ultra pure water
Sample examples
ø32
115.5
Across flats 29
ø26
(7)
ø26
20 35.5
100 KΩ·cm
20 35.5
1 MΩ·cm
10 MΩ·cm
18.24
Communications
output
Waterproof connector
10m
+5%
0
50
10m
100 MΩ·cm
Transmission
output
Connector type
(ø6.5)
Waterproof connector
Resistivity
Model
For flange mounting
165.5
(10 µS/m)
ERF-001 Series
20 35.5
10 µS/cm
50
1 µS/cm
2-electrode conductivity sensor ESH, FS series
■2-electrode conductivity sensor (General-purpose)
(Compatible converters: CE-200C, HE-480C, HE-960CW)
[Standard assembly]
(7)
0.0548
(1 µS/m)
0.1 µS/cm
(Unit: mm)
●2-electrode conductivity sensor
ø40
35
(SI unit)
0.01 µS/cm
2-electrode conductivity
Industrial Selection Guide for Conductivity Meter/Resistivity Meter
75
Resistivity
Measurement principle
Conductivity
The industrialtechnology and
Conductivity Meter and Resistivity Meter Lineups
165.5
Industrial
*1 For cable extensions, use relay box CT-20EC and limit extension to a max. of 50 m.
*2 Separate connector cable (SK-10M etc.) required for connector type sensors.
*3 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed.
*4 Separate threaded type adaptors EA-20 (for FES-125 sensors) and EA-40 (for FES-126 sensors) required.
14
Model
Product name
EA-20
Threaded type adaptor (for FES-125 sensor); Material: PVC
EA-40
Threaded type adaptor (for FES-126 sensor); Material: PVDF
The contents of this catalogue describe a standard specifications and codes. For custom specification according to your special needs, please contact our sales department.
15
■Sensor
(Unit: mm)
Our worldwide service network ensures speedy support,
when and where you need it.
●2-electrode sanitary conductivity sensor
■Flow-through sensor
FS-01 Series
■Connector cable
CK- ■M
■Insertion type sensor
ESH-01-C-S-SN-1.5S
Maintenance
space
50 or more
Maintenance
space
50 or more
Cable length: L
(ø6.5)
50
A
B
C
øD
A
2.5S
(140)
Model
82.5
(99.5) (103) (108.5) (114) (126.5)
55
85
110
65
75
Cable length
+5%
CK-Y10M
10 m 0
CK-Y20M
20 m +5%
0
CK-Y30M
30 m +5%
0
Japan
China
U.K.
HORIBA INSTRUMENTS
LIMITED
HORIBA TRADING (SHANGHAI) CO., Ltd.
HORIBA, Ltd.
HORIBA Advanced
Techno Co., Ltd.
HORIBA STEC
Co., Ltd.
HORIBA TECHNO
SERVICE Co., Ltd.
Shanghai Office
Beijing Office
ø17
(ø50.5)
●4-electrode sanitary conductivity sensor
10m
+5%
0
New Hampshire Office
Santa Clara Office
HORIBA Technology Center
10m
Austin Office
+5%
0
(105)
HORIBA STEC Co., Ltd., Aso Factory
35
Depending on
the coupling aperture of
the sanitary ferrule
Aperture 1.5S
ø29
øB
2.0S
2.5S
3.0S
4.0S
4.5S
øA
104
114
138
159
180
188
B
(80.5)
(86)
(98)
(109) (119.5) (123.5)
40
øA
73
(B)
)
( øA
Portland Office
(ø10)
Maintenance
space
100 or more
Maintenance
space
100 or more
Clamp-on gasket
(outside the scope
of Horiba delivery)
■Insertion type sensor
FES-210/220-L Series Cable-attached type
(ø10)
■Flow-through sensor
FES-310-L Series Cable-attached type
Aperture 1.5S
2.0S
øA
38.1
50.8
øB
50.5
64
(130)
Germany
France
■Flow-through sensor
FES-310-C Series Connector type
■Connector cable
SK- ■M
HORIBA FRANCE
SARL
■Insertion type sensor
FES-210/220-C Series Connector type
HORIBA EUROPE
GmbH
Singapore
Taiwan
HORIBA INSTRUMENTS
PTE. Ltd.
HORIBA, Ltd. TAIWAN
Representative Office
Korea
HORIBA
KOREA Ltd.
U.S.A.
HORIBA/STEC
INCORPORATED
Attach the SK series
connector cable.
Attach the SK series
connector cable.
50
(ø10)
Depending on the
coupling aperture of
the sanitary ferrule
øA
(91)
78
(B)
)
( øA
Maintenance
space
100 or more
Maintenance
space
100 or more
Cable length: L
Clamp-on gasket
(outside the scope
of Horiba delivery)
Model
35
ø21
Cable length
SK-Y10M
ø29
øB
+5%
10 m 0
+5%
0
SK-Y20M
20 m
SK-Y30M
30 m +5%
0
40
(130)
2.5S
3.0S
4.0S
4.5S
104
114
138
159
180
188
B
(80.5)
(86)
(98)
(109) (119.5) (123.5)
Maintenance
space
100 or more
■Socket insertion type
FES-240-L Cable-attached type
(ø10)
10m
+5%
0
FES-240-C Connector type
■VARIVENT® valve type
FES-230-L Cable-attached type
10m
(ø10)
Attach the SK
series connector
cable.
ø23.5
64
Please read the operation manual before using this product to assure safe and proper handling of the product.
● The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company.
● The color of the actual products may differ from the color pictured in this catalog due to printing limitations.
● It is strictly forbidden to copy the content of this catalog in part or in full.
http://www.horiba-adt.jp/index_e.htm
Head Office
31 Miyanonishicho, Kisshoin Minami-ku, Kyoto, Japan 601-8306
Phone: (81)75-321-7184 Fax: (81)75-321-7291
Attach the
SK series
connector
cable.
Tokyo Sales Office
Arule-Bldg, Higashikanda. 4th Fl, 1-7-8 Higashi-Kanda Chiyoda-ku, Tokyo, Japan 101-0031
Phone: (81)3-3851-3150 Fax: (81)3-3851-3140
Nagoya Sales Office
Sumitomoseimei Chigusa 2nd Bldg. 6th Fl, Aoi 3-15-31, Higashi-ku, Nagoya, Japan 461-0004
Phone: (81)52-937-0812 Fax: (81)52-937-0675
(ø84)
(91)
78
32 (17)
Socket
(outside the scope
of Horiba delivery)
50.5
ø38.1
(105)
78
32 (17)
ø34.2
50.8
øB
ø38.1
Keep at
least 12 mm
distance
from the
piping wall.
ø23.5
Socket
(outside the scope
of Horiba delivery)
16
16
(106)
73.5
43.5
ø34.2
(86)
73.5
43.5
ø44.2
ø41.8
38.1
+5%
0
(ø84)
ø44.2
ø41.8
2.0S
øA
FES-230-C Connector type
ø29
Tuhenhagen
DN40/50 plug
Keep at
least 12 mm
distance
from the
piping wall.
2.0S
øA
Maintenance
space
100 or more
Aperture 1.5S
Aperture 1.5S
Service Stations
●Kyoto: (81)75-321-7972 ●Tokyo: (81)3-3851-3150 ●Nagoya: (81)52-937-0812
ø29
Bulletin:HAE-S0141C
Tuhenhagen
DN40/50 plug
13
Industrial
Conductivity/Resistivity Meter
Sanitary
coupling
ferrule
1.5S
85
B
øD
1.0S 1.5S 2.0S
(120) (120) (120) (120)
55.5 59
70
64.5
131
(175)
C
ø21
Aperture 15A
Conductivity/Resistivity Meter
Selection Guide
& External Dimensions
Attach the
CK series
connector
cable.
Attach the CK series
connector cable.
Clamp-on packing
(outside the scope of
Horiba delivery)
Industrial
11
Printed in Japan
0902SK13
Download