New Product Information Fans Fans & & Blowers Blowers G CONTENTS New Product Information ‥‥‥‥‥‥‥‥‥G-0 Contents ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥G-1 Catalog Information ‥‥‥‥‥‥‥‥‥‥‥G-2 Product Features of Japan Servo Co. ‥‥‥‥G-3 Motor Selection Guide ‥‥‥‥‥‥‥‥‥‥G-4 Technical Data ‥‥‥‥‥‥‥‥‥‥‥‥‥‥G-6 DC Silent Fans ‥‥‥‥‥‥‥‥‥‥‥‥‥G-16 DC Axial Fans ‥‥‥‥‥‥‥‥‥‥‥‥‥G-22 DC Centrifugal Blowers ‥‥‥‥‥‥‥‥‥G-44 Variable-speed Fans and Blowers ‥‥‥‥G-58 Customized Fans and Blowers ‥‥‥‥‥‥G-59 AC Fans and Blowers ‥‥‥‥‥‥‥‥‥‥G-60 Guards, Filters and Plug Cords (Options) ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥G-72 ● Please visit our website for any technical inquiries or information. ● For non-technical inquiries, contact our local Japan Servo sales office or distributor in your area. ● This catalog contains only the latest standard products in the inventory and semi-standard products. Contact your Japan Servo sales office or distributor for details about customized and semi-customized products. ● Please visit our website for specifications and other information on former products release. ● The dimensions, specifications, and components contained in this catalog are subject to change without prior notice due to further product improvements. ● An electronic version of the catalog, containing 3D data of DC fans and blowers, can be forwarded upon request. Information can also be downloaded from the web2-CAD site (www.web2cad.co.jp). ● Contact Japan Servo Co. or a distributor if you wish to obtain product samples. G-1 AC/DC Axial Fans & Blowers AC/DC Axial Fans & Blowers Catalog Information The descriptions of the AC and DC fans and blowers appear on the product pages as shown below. Contact Japan Servo if clarification or further information is desired. Lineup of standard products and basic characteristics. Fan/blower noise in free air state. (Static pressure 0 Pa) (This value is sometimes considerably higher when the fan or blower is installed in your equipment. See pages G-8 to G-10) Silent Operable voltage range. (PQ characteristics vary depending on the operating voltage. See page G-7) Customizing, safety standards, 3D data. ● Our ceaseless quest to reduce noise Japan Servo continues to introduce a never ending series of quiet products to the market. People know to talk to Japan Servo if low noise is a priority, and that reputation has grown over many years. Day and night, Japan Servo is active in the research and development of low noise technology. Japan Servo also swiftly introduced computational fluid dynamics (CFD) to deliver quiet fans and blowers that customers can use without worrying about designing noise reduction measures into their application. All Japan Servo products conform to the EU RoHS Directive by restricting the contents of six specified hazardous substances (lead, mercury, cadmium, hexavalent chromium, PBD and PBDE) to below tolerable values. (All products produced from the beginning of January 2006 meet the RoHS Directive. Certain standard inventory products may include those produced in and before December 2005. Please specify in your purchase orders that only RoHS-compliant products should be shipped.) Japan Servo is also active in reducing another 18 hazardous substances. ● AC and DC fans One of the prominent advantages of AC fans is the fact that they can be directly connected to an AC power supply. The DC fan boasts high motor efficiency and is power-saving, as well as generating less heat, allowing the weight of the motor and venturi case to be reduced. AC fans and blowers use AC induction motors and are suitable for constant speed operation. DC fans and blowers, meanwhile, use DC brushless motors and can have highly variable airflow. By varying the voltage supply, the speed is also easily adjustable. Standard DC fans and blowers regulated by variable-speed control are also available. See pages G-40,G-41, and G-58 for further details. [Principal applications] ● Computers and peripheral terminal equipment ● Servers ● Personal computers ● Copiers ● Audio equipment ● Broadcastingt equipment ● Communication equipment ● Industrial equipment ● Medical equipment ● Game machines Fans Centrifugal Centrifugal ● Versatile lineup of energy saving products The power consumption of fans may be problematic with some high airflow products and with large fans and blowers. When several units are used, a high capacity power source must be installed. Japan Servo markets a large variety of high-efficiency fan motors that can reduce the power capacity required for such machines. Fan Characteristics ● Large airflow ● Linear intake and outlet ● Suitable for equipment with small ventilation resistance Blowers ● High static pressure ● Right angle intake and outlet ● Suitable for equipment requiring local cooling and with large ventilation resistance. G-3 Option Option Blower Features G-2 Axial Mounting hole dimensions as examples for fan mounting. (Recommended shapes to maximize fan performance characteristics) ● All Japan Servo catalog products conform to the EU RoHS Directive AC fans Axial AC fans List of fans and blowers with sensors. External dimensions, lead wire specifications. Products are supplied in optimum customized form for bulk purchases. Japan Servo is capable of swiftly accomplishing optimum designs by fully exploiting CFD technology. Japan Servo will propose optimum semicustomized fans and blowers by combining its large variety of customized parts. Let Japan Servo devise a suitable solution to meet your requirements. Silent Silent Wiring connection to the power source. (See page G-15 for the wiring connection to the sensors) Flange shape. (Select ribbed specification when screws are used) ● Customized and semi-customized product specifications Centrifugal PQ characteristics chart. (Drawing an estimated ventilating resistance curve will determine the airflow at the operating point) Important notes regarding the basic characteristics. List of products which do not meet the standard life. The aerodynamic characteristics required for fan motors differ depending on the equipment in which they are installed, but may roughly be grouped into airflow focus and pressure focus types respectively. The axial fans and centrifugal blowers (also called “centrifugal fans” and “sirocco fans”), as fan motors of Japan Servo, fall into both the former and latter categories. Recently, Japan Servo has also developed pressure focus type axial fans, suitable for use in high static pressure regions, in response to diverse customer requirements. As its name implies, an axial fan generates airflow in the motor axial direction. Airflow can be generated cylindrically by the propeller from the entire diameter of the fan, allowing considerable airflow generation. The axial fan sucks in air and pushes it out through the propeller blades, without large pressure (static pressure) output. The centrifugal blower, on the other hand, recovers the airflow released by the impeller blades in a centrifugal direction from the motor shaft center via the scroll casing (also called a “housing” or “frame”) and discharges it unidirectionally. This system effectively converts a centrifugal force into pressure, increasing the pressure (static pressure) to blow the air. However, only a limited airflow passes through the impeller, preventing a large airflow from being obtained. Japan Servo refers to the former as fans and the latter as blowers, to easily distinguish the differences between the two types. In addition to these two types, Japan Servo has recently released axial fans with features resembling those of the blower (high static pressure region fans, e.g. the G1751M series). These fans are attracting the attention of the IT industry and are highly rated as quiet products, capable of saving energy with high-impedance equipment, with which conventional axial fans have not been efficient. With product liability in mind, it is the logical responsibility of manufacturers to supply highly reliable products that can be used by customers without any product safety worries. Products with new designs are only supplied to the market after their viability has been verified by subjecting them to various high-temperature life tests and proving that they are problem-free. Moreover, only high-reliability parts are used in the drive circuits of DC fans and blowers. Japan Servo develops and designs products by specifying the strictest derating level in the industry. Axial Centrifugal Materials used, carton specification. Current value in free air state. (The current at the operating point will be an increment of 20 % or less of the rating with fans and will be below the rating with blowers. See page G-13) ● Versatile lineups of axial fans and centrifugal blowers Fans for high static pressure applications are also supplied as standard products. ● Only highly reliable products are delivered to customers DC fans Axial DC fans List of model codes. (Product codes for which orders are accepted) Startup current value. (Use to select the power source) Focusing on product development for computer related equipment, the compact axial fans from Japan Servo are the result of technological innovations that minimize noise to the greatest possible extent. Japan Servo's product designs incorporate several industry firsts, including specially molded 3-dimensional blades, and silent fans with a unique intake shape. Market requirements are always researched and catered to in advance; meaning customers always receive products that perform well ahead of market rivals. Fans & Blowers Fans & Blowers High customer satisfaction achieved thanks to our quiet and energy efficient products with unsurpassed reliability and customizability. ■ Catalog Information Guide Product photo, maximum performance, weight. Features of Japan Servo Co. Fans & Blowers Fans & Blowers Fans & Blowers Silent Axial DC fans Axial DC fans Centrifugal Centrifugal Silent Silent Axial AC fans Axial AC fans Centrifugal Centrifugal Option Option G-5 G-4 Motor Selection Guide (Blowers) Motor Selection Guide (Fans) AC/DC Axial Fans & Blowers AC/DC Axial Fans & Blowers AC/DC Axial Fans & Blowers AC/DC Axial Fans & Blowers Technical Data ■ Airflow - static pressure characteristics (PQ characteristics) 1. Pressure loss (Ventilating resistance) By minimizing the ventilating resistance of the equipment and by using power-saving fans and blowers, both cost and noise reduction can be achieved, resulting in an ideal cooling solution. (Actual example: Ventilating resistance was reduced and quiet operation achieved by changing the thickness of a 92 square fan from 32 to 25 with equipment having densely mounted parts (Ventilating Resistance 3 in Fig. 4). A force to obstruct the flow of air (pressure loss) is generated when air is channeled onto equipment, due to the parts layout and the shape of the air stream inside the equipment. This phenomenon is called ventilating resistance (also called “system impedance” and “channel resistance”). Air meets only modest resistance when it moves straight ahead within a wide space. (Fig. 1) When air passes through a narrow space or when the direction of an airflow changes, the ventilating resistance increases. (Fig. 2) The ventilating resistance increases further unless an outlet path (or a circulation path) is provided because an airflow cannot be created. Silent W ρ×C × T If an adequate air channel is not available due to a high density of mounted parts, a fan with a max. airflow of more than two times the required airflow is sometimes needed. In this case, a special fan for a high static pressure region or a blower is recommended. The following methods are used to accurately determine the ventilating resistance of equipment: 1) Send the equipment to a fan manufacturer and ask them to measure the ventilating resistance. 2) If 3D data of the equipment is available, ask the fan manufacturer to calculate the resistance. 3) Install a fan or a blower, whose relationship between the PQ characteristics and speed is already known, within the equipment and determine the ventilating resistance by measuring the speed. 5. PQ characteristics via the parallel or serial operations of axial fans Parallel operation of 2 fans Q : Required airflow〔m3/s〕 When two fans are operated in parallel, only the max. airflow will double. Intersections QF1 and QF2 with ventilating resistance curves of the equipment will be the airflow actually flowing. This mode is advantageous when wishing to increase the airflow of equipment with only modest ventilation resistance. W : Heat generation rate 〔 W 〕 ρ: Specific weight of air〔kg / m3〕 = W 1200 × T C : Specific heat of air 〔J / kg°C〕 T: temperature rise of air〔°C〕 (ρ and C are values at 25 °C. Use the value 1100 instead of 1200 at 50 °C) Example: When wishing to limit the air temperature rise inside equipment that generates 100 W of heat, the following calculation formula is used: Q = 100 = 8.3 ×10-3 m3 / s = 0.50 m3 / min 1200×10 7. Performance degradation of PQ characteristics when options are installed Options such as a fan guard and filter are sometimes installed for safety. These options, however, increase the ventilation resistance and noise. A fan guard has slight ventilation resistance and degrades the PQ characteristics only negligibly. However, when tightly fitted onto a fan, the noise level increases by about 5 dB. In particularly, options should be installed more than 10 mm away from the fan to minimize the increase in noise. Using a □120 mm×38 mm AC fan (CN55B3) as an example, fluctuations of the PQ characteristics when options are installed are plotted in Figs. 12 and 13. Centrifugal Centrifugal (Note: A fan specially designed for a high static pressure region will be further advantageous for equipment that has high ventilating resistance. [See Fig. 9.]) Axial When two fans are operated in series (stacked), only the maximum static pressure will increase by 1.5 times. Intersections QF1 and QF2 with ventilating resistance curves of the equipment will be the airflow actually flowing. This mode is advantageous when wishing to increase the airflow of equipment with high ventilation resistance. The speeds of fans and blowers vary in proportion of the voltage. Varying the voltage ±10 % will also cause the speed to vary by ±10 %. The speed affects the static pressure and airflow as follows. The static pressure varies based on the square of the speed and the airflow varies in proportion of the speed. Varying voltage±10 % will cause the maximum static pressure to vary ±21 %, and the max. airflow to vary ±10 %. (See Fig. 10.) An understanding of these relationships will allow free adjustment of the PQ characteristics during fan and blower operation. AC fans Axial AC fans An airflow of 0.50 m3 / min or more is required. This calculation formula for the required airflows (ventilation rate) can be translated into a graph as shown in Fig. 5. Serial operation of 2 fans (Note: Only test operation is allowed to be used outside of the specified voltage range. Note that this information is not applicable to AC powered fans, nor to certain DC fans. [Example: SADC fans] Please check the product information pages.) Silent Silent Serial operation of 2 fans with stationary blades for a high static pressure region When two fans are run in series (stacked), only the maximum static pressure will increase by 1.8 to 2 times. Japan Servo special fans for high static pressure regions have stationary blades and achieve a lower reduction in static pressure during serial operation. The intersections QF1 and QF2 with ventilating resistance curves of the equipment will be the airflows actually flowing. Option Option G-6 Q = DC powered fans and blowers have the following relationship between the imposed voltage and the PQ characteristics. The following information will be useful when fine tuning performance or when using a fan or a blower for experimental purposes: Centrifugal Centrifugal As illustrated in Fig. 3, the PQ characteristics exhibit characteristic trends when a motor of equivalent power is used. The fan has a large airflow and its static pressure is 1/2 to 1/5 that of the blower. The blower has large static pressure and its airflow is 1/2 to 1/5 that of the fan. In the absence of a ventilating resistance (0 Pa), the max. airflow (QFmax) flows, under circumstances where there are no objects located around the fan (This free air condition is the x-axis). However, this condition does not exist as long as a fan is assembled in equipment. The state showing considerable ventilating resistance and a lack of airflow corresponds to the y-axis in Fig. 3 and the airflow is zero because the air does not move. In this condition, there are obstacles in front and to the rear of a fan that prevent airflow or that shut off the circulation path of the air. This operating condition cannot be considered when a fan is used for cooling or ventilation purposes. (Continuing operation in this condition may damage the fan.) The actual operating conditions vary between the two aforementioned extremes. Fig. 3 plots four ventilating resistances (plotted via quadratic curves). Units of equipment containing either a fan or a blower have varying ventilating resistances, of which these four curves show typical examples. The airflow flowing into the equipment is at the intersection between the ventilating resistance curve and the PQ characteristics of the fan or the blower. The curve of Ventilating Resistance 1, which has the smallest inclination, is assumed to be the ventilating resistance of ordinary equipment. At this ventilating resistance, there are no large obstacles in front and to the rear of the fan and an adequate circulation path is provided. The fan can be operated most efficiently at this Ventilating Resistance 1, where about 80 % of the maximum fan airflow is possible. (Airflow of QF2 with a fan and of QB2 with a blower respectively) Of the four curves, the airflow of any equipment that has Ventilating Resistance Curve 4, with the largest inclination, will be a fraction of the max. airflow, even though a high performance fan or blower is installed. In this condition, the airflow will be QB1 with a blower and QF1 with a fan, the airflow of the blower being larger. The airflows of Ventilating Resistance Curves 2 and 3, in between, will also be airflows at the intersection with the respective PQ characteristics. Japan Servo supplies fans dedicated to a high static pressure region, with fan motors optimally designed for intermediate ventilating resistances. As Fig. 4 explains, quieter and energy saving operations are more feasible in the high static pressure region compared with ordinary axial fans. (See page G-42) The required airflow and ventilating resistance of equipment must be determined when selecting a fan or a blower. However, accurate determination of a ventilating resistance is difficult. In general you can select a fan's max. airflow by multiplying the required airflow by 1.3 to 1.5. (The following figure [Fig. 6] shows the case of an air channel with an area approximately equal to that of the fan.) Axial 2. Differences in PQ characteristics of fans and blowers The method to calculate the required airflows (ventilation rates) is described for the cooling of equipment which generates heat. The airflow (ventilation rate) necessary for internal equipment cooling is calculated as follows: (Note: the entire heat is exhausted by ventilation airflow and heat from radiation or conduction is not taken into consideration) 6. Voltage imposed to fan and blower and PQ characteristics DC fans Axial DC fans 3. Method for calculating the required fan airflow 4. Fan and blower selection Fans & Blowers Fans & Blowers Characteristics of Fans and Blowers Technical Data G-7 AC/DC Axial Fans & Blowers AC/DC Axial Fans & Blowers Technical Data Technical Data ■ Noise 5. Noise calculation 8. Object distance and noise value At present, the PQ characteristics are expressed in Japan by Pa (static pressure) and m3/min (airflow). Use the following conversion tables for conversion between CFM, which is used in some countries, and between the units previously used in Japan. 1. Types of noise Noise is a sound pressure value measured in a position where the energy of a sound source arrives. It is called a sound pressure level (SPL) and is expressed in dB. If the sound energy increases 10 times, the sound level increases 10 dB and 60 dB represents sound pressure energy that is 1000 times that of 30 dB and 10000 times that of 20 dB. The total noise of several fans is calculated as follows: (Noise values of individual values are L1, L2 ........ Ln) The noise value (SPL) decreases as the sound source becomes distant while the fan noise value varies in proportion to the square of the distance and can be expressed by the following formula: (When the reflection sound to nearby walls is ignored) DB2 = dB1 - 20 log (L2/L1) dB1: Noise value when the distance from the sound source is L1 dB2: Noise value when the distance from the sound source is L2 kgf/cm2 1.02×10-5 1.00×10-4 2.54×10-3 1 1.03 1.02 7.03×10-2 atm 9.87×10-6 9.68×10-5 2.46×10-3 9.68×10-1 1 9.87×10-1 6.81×10-2 bar 1.00×10-5 9.80×10-5 2.49×10-3 9.81×10-1 1.01 1 6.90×10-2 Ibf/in2 1.45×10-4 1.42×10-3 3.61×10-2 14.2×101 14.7×101 14.5×101 1 m3/h ft3/S CFM 3 3.60×10 3.53×101 2.12×103 6.00×101 5.89×10-1 3.53×101 3.60 3.53×10-2 2.12 6.00×10-2 5.89×10-4 3.53×10-2 1 9.81×10-3 5.88×10-1 1.02×102 1 6.00×101 1.70 1.67×10-2 1 Vibration sound Mechanical motor vibration sound・ ・ ・Imbalanced revolutions, resonance and vibration transfer sound. Electromagnetic sound of motor・ ・ ・Vibration sound by phase change (switching). Cavity noise Example: If four fans individually emit noise of 30 dB, 35 dB, 40 dB and 45 dB, the total noise of the four fans will be: L= 10 log(10 30/10+ 10 35/10+ 10 40/10+ 10 45/10) = 46.6 dB If all three fans emit 40dB, their total noise will be: L= 10 log(10 40/10+10 40/10+10 40/10) = 40+10 log3 = 44.8 dB The noise can be calculated from the following graph in Fig. 16 if the noise difference between two fans is 13 dB or less: Air column resonance and other sounds 2. Noise of fan The noise of the fan itself (catalog noise) is measured in a small anechoic room, in which background noise is adequately low, in a free-air state with no objects surrounding the fan. The aerodynamic noise (blade sound) and motor sound are the principal noise sources. 9. Measurement method of PQ characteristics 3. Noise after installation in equipment 4. Noise measurement Speed -1 2000 min(Standard) 2200 min-1 2600 min-1 3000 min-1 4000 min-1 0 +2.5 dB +6.8 dB +10.6 dB +18.1 dB Load noise of blower Load noise of fan (CNDC24B7) (E1331K and SCBD [former model]) 100 50 90 45 80 40 70 35 60 50 40 30 300 Propeller diameter 0 200 150 100 50 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Airflow(m3/min) Fig. 17 50 45 40 35 250 0 SCBD12B4 E1331K24B5AZ 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Airflow(m3/min) Fig. 18 Centrifugal Centrifugal Noise meter 86 mm 114 mm(Standard) 121 mm 142 mm −22.2 dB −12.7 dB −8.6 dB 0 +1.8 dB +6.7 dB +34.8 dB +20.0 dB +13.5 dB 0 −2.8 dB −10.5 dB Option Option 75 mm Fan manufacturers note the noise values in their catalogs assuming a free air condition (ventilating resistance 0). When fans are physically assembled in equipment, the ventilating resistance cannot be zero and the noise values listed in catalogs are for reference purposes only. A method used to estimate sound values when fans are assembled in equipment is described below. A noise value at each point of the PQ characteristics is called "load noise" and fans and blowers have their own characteristics. (See Figs. 17 and 18.) The load noise is the noise of the fan itself at the point of operation. Fan characteristics include a "neck" (dip) in the plotted curves. This dip is caused by turbulence in the airflow on the propeller surfaces and noise increases steeply between this part and a low airflow region. The fan has an area where noise becomes lowest (region of higher airflow than the neck). The circulation path should be designed such as to reduce ventilating resistance. However, if the ventilating resistance cannot be reduced with any equipment after trying various ideas, the study of fans for a high static pressure region is recommended. These are fans that have been developed and designed to emit low noise in a high static pressure region compared with ordinary fans. (See Fig. 4 on pages G-6 and G-42.) As plotted in Fig. 18, the load noise of blowers generally varies only slightly, while trends in load noise differ from one product to another of the blower manufacturers. Even if the catalog values are the same, noise invariably varies at the same operating point. The blowers manufactured by Japan Servo are designed to emit the lowest noise at customers' operating points so that the customers can base catalog load noise values reliably as actual blower noise. 10 Noise meter 55 mm 9. Ventilating resistance and noise value 20 7. Propeller diameter and noise level Noise value with equivalent speed Noise value with equivalent airflow −3.5 dB Axial Noise value The fan noise is strongly linked to the propeller size. Comparing the noise of fans with equivalent speed, the noise theoretically varies to the seventh power of the propeller diameter as follows: In reality, the propeller shape is not symmetric and calculations cannot be performed as explained in the theory. However, the noise value with equivalent airflow rate will be as shown in the following table, indicating that a larger fan will reduce noise. (Value calculated based on the theory that the airflow varies to the third power of the propeller diameter) DB2 = dB1 + 70 log (D2/D1) dB1: Noise value when the speed is D1 dB2: Noise value when the speed is D2 Fig. 15 G-8 A fan´s noise value is the total of the aerodynamic and motor noise. Most noise is aerodynamic in nature, except in products with a low speed. The speed and noise value vary in proportion to the sixth power and the noise value increases when the speed increases. (Some people say that they vary in proportion to the fifth power.) Increasing the speed will double the max. airflow and quadruple the maximum static pressure. Noise increases 18.1 dB (+15 dB at the fifth power). DB2 = dB1 + 60 log (N2/N1) dB1: Noise value when the speed is N1 dB2: Noise value when the speed is N2 150 cm 0 AC fans Axial AC fans Noise is measured in accordance with the test method specified in JIS C 9603 Ventilating fans in Range A measurement, placed in a position 1 m in front of the intake side of fans and blowers. (Background noise 15 dB (A)) 6. Speed and noise value 1m (Standard) +6 dB Silent Silent After installing the fan in your equipment the noise level sometimes increases drastically (up 8 dB to 15 dB) compared with the noise emitted by the fan itself. This is caused by the resonance of the fan vibration within the equipment, an obstacle in front of the intake (the fan guard may also become an obstacle), an increase in load noise due to ventilating resistance, the use of a fan with excessively large power, an insufficient circulation path, and other causes. Noise can be reduced significantly by reducing the factors that increase noise. (In the best case scenario, only the noise level of the fan itself is generated) Japan Servo provides a service to analyze customers' equipment noise. Please contact Japan Servo with your requirements. 50 cm source Noise value Centrifugal Centrifugal The aerodynamic characteristic measuring apparatus is illustrated in Fig. 14. This apparatus conforms to the ANSI/AMCA Standard 210-85, as well as JIS B 8330 (Testing methods for turbo-fans). It is very difficult to measure PQ performance with high accuracy and the various measuring equipment used by fan manufacturers feature a wide range of accuracy. For this reason, simultaneous acquisition of comparable data obtained by the same measuring apparatus is recommended when verification of strict variation in performance is desired. (Japan Servo also measures the comparative data of fans manufactured by other fan manufacturers as a customer service - please make use of this.) Distance from sound Axial I/min 6.00×104 1.00×103 6.00×101 1 1.67×101 1.70×103 2.83×101 Turbulence in inflow flow, random eddy discharge from the eddy flow boundary layer on blade surfaces and air separation. (L) ) = 10 log( 10L1/10 + 10L2/10 + ……………10Ln/10 ) Total noise( DC fans Axial DC fans m3/s m3/min l/S 1 6.00×101 1.00×103 1.67×10-2 1 1.67×101 1.00×10-3 6.00×10-2 1 1.67×10-4 1.00×10-3 1.67×10-2 2.78×10-4 1.67×10-2 2.78×10-1 2.83×10-2 1.7 2.83×101 4.72×10-4 2.83×10-2 4.72×10-1 Eddy flow sound Aerodynamic noise Mechanical noise Table 2 Airflow conversion table Noise of rotation Propeller sound・ ・Sound emitted by the revolutions of blades Periodic flow fluctuations of flow・ ・ ・ ・ ・Interference and air separation with stationary blades, strut and venturi. Load noise (dB (A)) inH2O 4.02×10-3 3.94×10-2 1 3.94×102 4.07×102 4.02×102 2.77×101 Static pressure (Pa) mmH2O 1.02×10-1 1 25.4×101 1.00×104 1.03×104 1.02×104 7.03×102 Load noise (dB (A)) Silent Pa=N/m2 1 9.81 2.49×102 9.81×104 1.01×105 1.00×105 6.9×103 Static pressure (Pa) Table 1 Static pressure conversion table Noise is generated by the combination of various conditions. Measures to eliminate or reduce noise can be taken more easily by analyzing the details of the noise. When reducing the noise of your equipment, take into account the following factors that contribute toward noise generation: Fans & Blowers Fans & Blowers 8. Unit conversion tables of PQ characteristics G-9 AC/DC Axial Fans & Blowers AC/DC Axial Fans & Blowers Technical Data Comparison of noise generating sources When mounted directly onto a fan, a fan guard increases noise by about 5 dB. Install a fan guard more than 10 mm from equipment to reduce the increase in noise. ● Silent Fan Intake air flows in a fixed direction and at a constant flow velocity along the arc on the edge, hardly producing any noisy eddy turbulence. 11. Equipment resonance with fan Silent The fan contains a motor that causes mechanical vibration and electrical vibration, which sometimes causes equipment containing a fan to resonate. This problem can be solved by combining the following three methods: 1) Cut off the vibration transfer route to equipment by providing a rubber vibration isolator or other cushioning. 2) Change the natural frequency of equipment by changing the board thickness or by other means. 3) Change to a low-vibration fan (customized product), in which case consult Japan Servo for more information. 12. Quiet operation by Silent Fan Applicable standards The life of fans is solely dependent on bearings. The bearing load P in relation to the basic rated load C is P<<C, (meaning P is a great deal smaller than C). Therefore we can say that grease life determines the fan life. Grease life is significantly affected by ambient temperature. The fans of Japan Servo feature a special design that minimizes grease temperature rises as illustrated below. Japan Servo fans and blowers have been accepted in certification tests for Japanese and overseas safety standards for use in various applications. (Please inquire to Japan Servo for standards that are not included in the following.) The AC fans that fall under the scope of the Electrical Appliance and Material Safety Law are manufactured in compliance with its technical standard. AC fans are classified as fans and blowers in one of 480 electrical appliance item categories other than specified electrical appliances. The marking of the (PS)E mark is a legal obligation. See page G-60 and subsequent pages for Japan Servo products with the (PS)E mark. Power plug cords are classified as specified electrical appliances and the marking of the〈PS〉 E mark is a legal obligation. (See page G-74.) Sectional view Fig. 19 ● Square Venturi Fan ◆ Certification test by the UL Standard Sectional view Fig. 20 100,000 L10 life hours (Hr) Axial Japan Servo fans and blowers have been accepted in certification tests, based on general specification requirements and rules to prevent overheating inside motors under fan and blower safety test standard CSA STANDARDS C22.2 Nos. 113 and 0.077 of the CANADIAN STANDARDS ASSOCIATION, the electrical appliance safety inspection organization of Canada. Products that are accepted in certification tests are marked with the mark on their nameplates and model names are registered, to attest that they are certified products under the CSA standards. The registration No. of Japan Servo is LR49399: Made in Japan LR108118: Made in Indonesia As with the UL standards, safety verification is performed by ensuring non-regular factory audits are performed by CSA. (Some products are certified by the + mark.) AC fans Axial AC fans 10,000 ◆ Certification test by the CSA Standard Silent Silent The fan motor contains two parts which generate heat, namely, the stator and rotor. The AC fan holds a bearing in a dedicated sleeve to help retard the transfer of heat generated by the rotor, and limit the temperature rises of the bearing. The DC fan has an external rotor structure and the temperature of the bearing is significantly affected by stator temperature. When the speed rank rises, the motor temperature also rises, thereby increasing the heat transfer to the bearing. Japan Servo fans feature a high-efficiency circuit and low motor losses to keep the bearing temperature below the preset temperature, thereby ensuring a long life. The bearing temperature differs depending on the structure, materials and other factors and life varies to some extent. However, the life expectancy as illustrated in Fig. 23 is the basic data. Japan Servo accepts inquiries and orders for semi-customized products (long life products) featuring a reduction in bearing temperature increase. Please contact Japan Servo for further information. The life expectancy curve that is common to AC and DC fans is plotted in Fig. 23. (The curve represents the life expectancy based on a survival rate of 90 % and is not the guaranteed life. Japan Servo will provide the MTTF (mean time to failure) data upon request.) Japan Servo fans and blowers have been accepted in certification tests under the fan and blower safety test standard UL-507,73 of UNDERWRITERS LABORATORIES INC., the electrical appliance safety inspection organization of the United States. Products that are accepted in certification tests are marked with the mark on their nameplates and model names are registered, to attest that they are certified products. The registration No. of Japan Servo is E 48889: Fans and blowers E 78112: Plugs and cords (Category Nos. W1007, W1008) Non-regular factory audits by UL are conducted in connection with the production of certified products and safety verification is performed by ensuring the materials used, electrical characteristics and other items pass strict factory test inspections. Centrifugal Centrifugal Turbulence ■ Long-life structure Axial The airflow on the intake side is not constant. Differences in flow velocity and direction cause shear flow and trigger periodic lift fluctuations, leading to noise generation. The air separation phenomenon occurs in the edge part, which is the thinnest part of the square venturi and round intake side, generating many eddy turbulences and increasing propeller resistance, thereby causing noise. (Note: In recent years further progress in CFD (Computational Fluid Dynamics) technology has enabled the development of new concepts to retard shear flows. These concepts will be applied to our easy-to-use square fans to substantially reduce noise. Be sure to look for these new products coming soon.) ◆ Certification test by TUV 10 20 30 40 50 Ambient temperature (℃) 60 70 80 Fig. 23 Life expectancy curve (Survival rate 90 %) G-11 Option Option (Note: This life expectancy curve has been prepared based on the results of life tests conducted at a rated voltage in a free air condition in an environmental test room with a negligible amount of dust. When using the fans in your application please take into consideration the actual operating conditions and safety factors. Some of the products contained in the catalogs do not meet the foregoing life expectancy data. [Products which do not meet the standard life are listed on the product information pages.]) (Definition of life: End of life is defined when the speed or noise of a product deteriorates by 20 %) Japan Servo fans and blowers have been accepted in safety certification tests based on the Business-Use Electrical Equipment Standard EN60950 and the VDE Standard No. 0806/08.81 of T RHEINLAND e.V, the industrial electrical appliance safety inspection organization of Germany. Products that are accepted in certification tests are marked with the mark on their nameplates and model names are registered, to attest that they are certified products under the TUV standards. The registration Nos. of Japan Servo are: LICENCE No.:R60299, R60300, R60301, R60302, R9451586 :R9750695, R9750455, R9650662, R2-50004410 REPORT No.:E61087, E61088, E61089, E61090 As under the UL and CSA standards, safety verification is performed by clearing non-regular factory audits by TUV. Centrifugal Centrifugal 1,000 G-10 ◆ Electrical Appliance and Material Safety Law (Japan) DC fans Axial DC fans The rotating sound (blade sound) is the principal factor generating the noise of ordinary square axial fans. The frequency characteristic of these fans peaks at the number of blades x speed and the related high frequency component. This is mainly caused by periodical fluctuations of blade lift due to non-uniform airflow (turbulence), caused by an object on the upstream side of the fan and attributed to the shape of the fan venturi. The Japan Servo Silent Fans, part of the range of axial fans with a unique venturi shape, are renowned for their particular quietness. Compared with conventional square venturi Japan Servo products, the noise emitted by the silent fans are 5 dB to 8 dB lower. To prevent non-uniform airflow on the upstream side of the fan, the venturi mounting flange has a single flange on the outlet side only, as illustrated in Fig. 19. The intake flow velocity and direction of the fan are made constant through analysis of the air intake flow to prevent separation of flow from the peripheral parts of the venturi, thereby achieving exceptional quietness. Thanks to the design preventing flow disturbance on the intake side when a fan is mounted, a premium silence effect unrivalled by conventional square fans is achieved. Life of fans and blowers Fans & Blowers Fans & Blowers 10. Fan guards increase noise Technical Data AC/DC Axial Fans & Blowers AC/DC Axial Fans & Blowers Technical Data Impedance protection method Japan Servo fans and blowers have been accepted in safety certification tests based on the Fan and Blower Safety Inspection Standard DIN VDE0700 of VERBAND DEUTSCHER ELEKTROTECNICKER e.V, an electrical appliance safety inspection organization of Germany with the highest authority. Products that are accepted in certification tests are marked with the mark on their nameplates and model names are registered, to attest that they are certified products under the VDE standards. The registration No. of Japan Servo is 3019. As under the UL, CSA and TUV standards, safety verification is performed by clearing non-regular factory audits by VDE. This method is generally used with shaded pole induction motors. Temperature increase is limited below a preset value by impedance (AC resistance) natural to the motor windings. In particular, the UL standard specifies that motors must not burn out when the rotor is operated for 18 days at normal temperature (24 °C). Japan Servo fans and blowers meet this standard. Those products that are controlled by the Electrical Appliance and Material Safety Law of Japan are designed to limit coil temperature rises to less than 75 K. The impedance protection method is effective only within the usage range. Note that smoke will be generated and ignition caused if a high voltage is imposed. 3019 Common electrical specifications (Operational cautions) Silent ● Insulation class ● Insulation resistance Yield strength to static noise: The yield strength between the lines or between a frame and line is 5 kV. Yield strength to induced noise: Yield strength by an induced noise test apparatus is 2 kV. Note 1: Malfunction of the sensor alarms will result if the induced noise exceeds 1 kV. Insert a 0.1μF capacitor between the sensor line and ground as a precaution. Note 2: Some of the products without a 15-digit product code cannot guarantee these yield strengths. Contact Japan Servo for further information. ● Static electricity control A static electricity measure is needed if a terminal trailing from the fan motor is touched, otherwise the circuit is prone to damage by static electricity. ● Handling of the alarm output lead wires Inadvertently using a tester or other apparatus with a sensor lead wire will cause overcurrent to flow to the sensor circuit inside the motor, potentially causing a circuit fault. Pay attention to the permissible current and prevent any overcurrent from flowing. Contact Japan Servo if it becomes necessary to connect an LED or relay directly to a sensor lead wire. (There are products that allow a current larger than the permissible current described on page G-15 depending on conditions.) ● DUTY (PWM) control of DC fans and blowers The locking protection circuit does not function properly if variablespeed operation is performed through DUTY (PWM [pulse width modulation]) control of the power lead wire using a speed controller sold on the market or other device. The alarm output does not function properly with fans that are installed with sensors. As mentioned earlier, caution should also be exercised with surge voltage that occurs during ON-OFF switching in DUTY control. Please note that this operating method increases fan vibration, increasing the likelihood of abnormal sounds due to vibration. Dedicated fans and blowers are recommended for variable-speed operations. (See pages G-40, G-41, G-58, and G-59.) ● Connect multiple DC fans and blowers in parallel Connect multiple fans and blowers in parallel to the power supply. A serial connection (example: two 12 V products connected serially to a 24 V power supply) will cause the voltage for each product to fluctuate, resulting in a drastic excess of the usage range and circuit failure. Please direct your questions or inquiries to Japan Servo Sales or to the Japan Servo website. ● Power supply selection for DC fans and blowers Select a power source that supplies smooth power (ripples within ±5 %, peak within operating voltage). Significant line noise (including surge voltage) causes circuit faults. Make it a point to check line noise after assembling a fan. Select a power source remembering that a current 2 to 5 times the rated current flows at startup. (If an inrush current [normally less than 10 μs] poses a problem, measure it and take action accordingly.) The operating current peaks when the motor load is largest (at maximum static pressure for fans and in free air condition for blowers). When assembled, the current sometimes exceeds the rated current (fans) or smaller (blowers). (See the diagrams below.) When current is flowing, connect all terminals from the fan motor before turning it on. Imperfect wiring connection or a wiring change while the power is turned on will damage the circuit inside the fan or cause it to deteriorate. Axial The values described in the catalog are average values. Please request Japan Servo to send a product drawing or delivery specification for products when wishing to confirm standard values. ● Yield strength to electrical noise AC fans Axial AC fans ● Electrical performance Always perform ON-OFF control on the + side. ON - OFF control on the ground level causes circuit failure. ON-OFF control directly before a DC fan or a blower (between a fan and power supply) increases the risk of failures due to the counter-electromotive force from the motor coil. In this case, be sure to insert a diode or other device in parallel. Surge voltage can sometimes be generated with DC fans and blowers due to a wiring condition or other reason, even if the power is turned off. Insert a diode or other device in parallel to the power lead wire when the equipment requires very high reliability. (Recommended diode: With a capacity to withstand reverse voltage and a starting current 3 times the rated voltage) Silent Silent The insulation resistance of the AC and DC fans and blowers of Japan Servo is 10 MΩ or higher at 500 V DC between the power terminal or lead wire conductor and frame. Insulation resistance tests are conducted between the power terminal of the fan/blower or lead wire conductor (two lead wires tied together) and metal frame (or other metal part) using an insulation resistance tester. The DC fans and blowers embed a reverse connection protection circuit. Fans or blowers will not fail, even if connected in reverse within the usage range. (The fans or blowers will not activate, as no current flows to the circuit.) Centrifugal Centrifugal The AC fans and blowers of Japan Servo satisfy 1500 V 50 Hz for one minute or 1800 V 50 Hz for one second. Dielectric strength tests under JIS C 4004 specify a voltage impression of "2 x rated voltage + 1000 V." The DC fans and blowers of Japan Servo are accepted in withstand voltage tests of 500 V 50 Hz for one minute or 600 V 50 Hz for one second. The interrupting current of 5 mA is set for the dielectric strength testers. Dielectric strengths are tested between the power terminal of the fan/blower or lead wire conductor (two lead wires tied together) and metal frame (or other metal part) using a dielectric strength tester. The windings of DC fans and blowers are protected against abnormal temperature rises by automatic reset, by shutting off the current if it detects a locked state or by current limiting automatic reset. This method involves the energizing circuit being turned off by a lock detection function inside the motor drive circuit when the fan is locked, shutting off (or limiting) the current. Operation is reactivated automatically after the locking is reset. Note that this protection system does not function properly if used with duty (PWM) control power supply. Japan Servo supplies variable-speed fans whose speed can be variably controlled by a PWM signal. (See pages G-40, G-41, and G-58.) ● Power ON and OFF of DC fans and blowers Axial ● Dielectric strength This method is used with motors of a capacitor phase advancing type or triple-phase induction motors. Embedding a bimetal switch with a contact in the motor winding part, the current is shut off when the preset winding temperature is exceeded, to prevent burning caused by abnormal overheating of the motor. ● Reverse connection protection DC fans Axial DC fans The insulation class of AC and DC fans and the blowers of Japan Servo meet the heat resistance performance of Class E (120 °C) under JIS C 4004 (Rotating electrical machines - General), CLASS A (105 °C) under the UL703 standard, CLASS A (105 °C) under the CSA-C22.2 standard, and DIN IEC950/VDE0806 standard and CLASS E (90 °C) under the VDE0700 standard. Thermal protection method Vital Precautions for DC Fans and Blowers Fans & Blowers Fans & Blowers ◆ Certification test by VDE Technical Data ● Temperature protection Centrifugal Centrifugal Two methods are used to protect the temperature of the windings of AC fans and blowers, namely, impedance protection and thermal protection. These two methods are used differently depending on the type of motor used. Option Option G-12 G-13 AC & DC Fans & Technical Data ■ Operational precautions The products of Japan Servo are designed and manufactured to be as versatile as possible. Nevertheless, exercise caution with the following: 1. Operating environment Ic = 5 mA max. Yellow Reset speed Detection speed High +28 V max. R Low 0V 2 s or less or 5 s or less Sensor output ■ Sensor type 1. Lock detection type (Product code: S) The output signal indicates an [L] state (transistor is ON) while the propeller is rotating, changing to an [H] state (transistor is OFF) less than five seconds after the propeller stops rotating. The propeller automatically restarts operation within five seconds when the lock is unlocked. ([H] → [L] 5 s). If the pull-up voltage is live, the [H] state (transistor is OFF) will engage in less than five seconds, even when the power is turned off. ● Specification: VCE = 28 V max (55.2 V max for 48 V products) IC = 5 mA max (VCE (SAT) = 0.4 V max) ● Output waveform Locked Unlocked When the blades are turning 5 s or less When the blades are turning 1 s or less 5 s or less Note: The output waveform for type SQ (R) will be reversed. The speed setting for the alarm output is about half the rated speed. For more detailed information, please request a product delivery specification from Japan Servo. AC fans with sensors By equipping the motor with a rotation detection function, the AC fans of Japan Servo have a system to send an alarm signal when the fan motor revolutions slow down and to cut off the system power supply. In 1980, Japan Servo developed a system to output an alarm signal by detecting the lowering of generated voltage by installing a tachometer generator with the cooling fan and this system has since been incorporated in Japan Servo products. The output type of the alarm signal is an open collector output. VH Fan ■ Sensor specification Ic = 5 mA max. Yellow 1. When placing an object on the fan intake side, try to maintain a distance of more than half a blade diameter. L 0.5 D> 2. The pressure varies on the fan intake and outlet sides. The leakage of air from the outlet side causes noise. Minimize air leakage from the outlet side when installing a fan. Air leak ● Ventilating resistance can be expressed by the following formula: N +28 V max. VL 0V Sensor output sec. ※When the power is turned on, the state sometimes becomes high [H] for several hundred ms. 2. Pulse output type (Product code: P) A rectangular wave of two pulses will be output for each turn of the propeller while the propeller is rotating, outputting two types of signal depending on the propeller position when the propeller is locked. (See the note below ※) 3. Design the channel (circulation path) selecting a good flow direction in terms of both noise and PQ characteristics. P=0.000243Q 2 Σ i=1 R (VCE (SAT) = 0.4 V max) Fan 1 Ic = 5 mA max. Yellow VL 0V R +28 V max. T2 T3 T4 sec. T0 (1 turn) T1∼T4 ≒ 1/4 T0 = 60/4 N (sec.) ※Output signal waveform when the fan is stopped: The following two types of waveform are output, depending on the blade position when the propeller is stopped: Pulse outputs of High - constant or restart timing (0.05 Hz to 2 Hz). ● Avoid any sharp change in flow direction. Operate fans and blowers at an ambient temperature of between -10 °C and 60 °C and relative humidity of less than 90 %. Latch output is not used so malfunction by electrical noise can be ruled out. However, note that the semiconductor devices in the internal circuitry may be damaged by electrical noise and high voltage. No delay circuit is provided so a trouble signal is output on startup. As when operating and handling the fan, exercise caution to avoid dropping and exposing the blower to shock and vibration. ■ Sensor connection Yellow White Output 0V 2. Relay operation 1. LED Display +V 3 R >V×10 Ω 40 0 +V Relay coil 0 Use in tandem with a flyback diode. Limit the coil current to 50 mA or less. ※ A sensor is available with the AS ad PL series only. G-15 Option R Sensor circuit Option Sensor circuit The output signal indicates the [H] state when the propeller revolutions are slower than the preset speed, changing to the [L] state when the propeller revolutions exceed the reset speed. [Products with a reversed output waveform are also available, suitable for a wired OR connection when several fans are installed. Contact Japan Servo for further information. {Former code: SQ, new code (15 - digit code products): R} ] ● Avoid placing a printed circuit board and other parts orthogonal to the flow direction. Centrifugal 3. Speed detection type (Product code: Q) 4. Drill fan mounting holes to ensure the smooth flow of air to reduce noise by referring to the recommended dimensions for fan mounting holes on the fan or blower's catalog page. Axial Sensor output T1 AC fans A reduction of Ai (the channel cross sectional area) is critical. Avoid any sharp change in the cross sectional area in the flow direction. ■ Operational and handling precautions VH 2 Ai ● Output waveform ● Specification: VCE = 28 V max (55.2 V max for 48 V products) IC = 5 mA max Sensor circuit Centrifugal G-14 Normal speed Silent Axial AC fans The fan motors of Japan Servo contain double side shielded precision ball bearings. Dropping the product could result in abnormal noise (Brinell dent) of ball bearings during operation. Exercise care when handling the products as follows: 1. Product falling: Avoid dropping the product from a height of 5 cm or higher. 2. Falling of crated product: Avoid dropping a crated product from a height of 30 cm or higher. 3. Storage and stacking of crated products: Crated products may be stacked up to seven layers. Take sufficient precautionary measures to prevent getting them wet. Startup Centrifugal Silent ■ Handling precautions Fan ● Output waveform L 3. Installation orientation There are no installation orientation limitations for products containing ball bearings. Operate fans and blowers in compliance with the operating environment temperature and other conditions. Contact Japan Servo for further information or if clarification is needed. The DC fans and blowers of Japan Servo have a function to send an alarm signal when the fan motor revolutions slow down. Several systems are used to cut off the system power supply by this alarm signal, with three types of sensors available. Select the right type of sensor in accordance with the purpose of use. The lead wire for the sensor is yellow. The output type is an open collector output for all three types. ● Specification: VCE = 28 V max (55.2 V max for 48 V products) IC = 5 mA max (VCE (SAT) = 0.4 V max at 5 mA) Axial Centrifugal 1) The permissible range of AC fans and blowers is ±10 % of the rated voltage. Operations outside of the rated frequency result in considerable fluctuations in performance and life. Operations in serial connection (example: two 100 V products connected serially to a 200 V power supply) will increase the imposed voltage beyond the permissible range and should be avoided. 2) Use a sufficiently smooth power supply with DC fans and blowers. (Ripples of ±5 % or less, and peak within the usage range) The usage range differs from one product to another. Check it on the product information pages. • Strive to ensure the channel shape is as smooth as possible to avoid stagnation in the airflow. • Make the flow velocity larger around the object for which cooling is desired. • Place the fan on the downstream side when wishing to cool the entire space inside the equipment. • An upward flow in conjunction with the ascension of heated air is recommended for airflow inside equipment. • Take actions to mitigate the impacts of fans and for reverse flow in the event of failure where multiple fans are installed. DC axial fans & blowers with sensors DC fans Axial DC fans 2. Imposed voltage and frequency ■ Fan operational precautions Air separation Silent 1) Only highly durable flame-retardant resin is used. Nevertheless, avoid the presence of petroleum oil, such as cutting fluid and toxic gas from contact with resin sections of fans and blowers where such oil or gas is frequently used in operation by installing a filter or other apparatus. (If the operating environment cannot be improved, Japan Servo will be glad to conduct a yield strength verification test upon receipt of fluid and other item/s. Consult Japan Servo for more information.) 2) Open-type motors are used. The use of a fan or blower in a dusty place will adversely affect the circuit and ball bearings. 3) Avoid operating a fan or a blower in relative humidity exceeding 90 %. 4) The maximum storage temperature is normally 70 °C. Products with an operating temperature of 70 °C or higher can be operated only up to the specified temperature. Check the operating temperature range on the product information pages. 5) Exercise reasonable care with condensation when returning to an environment higher than 0 °C from storage or operating conditions below freezing point. Condensation results in failure and shortens the life. 6) The life may shorten considerably if a fan or a blower is installed in equipment that vibrates prominently. Japan Servo products conform to JIS C 0040 (Vibration testing methods for small motors) and withstand a maximum vibration acceleration of 9.1 G maximum (10 Hz to 55 Hz, amplitude 1.5 mm, sweep 1 minute/cycle, two hours each in X, Y and Z directions). However, operation at 5 G or less is recommended. 7) AC and DC fans and blowers cannot be operated while the intake side is tightly closed. This will shorten the motor life and result in circuit failure. 8) Operation near a high frequency power source may on rare occasions cause inflow of an induced current into the inside of a fan, shortening the life (and increasing noise due to BB galvanic corrosion). If an induced current flows, measures to prevent such inflow are needed. 4. Do not apply a load of 2 kgf or more to the connecting part of the lead wire of a DC fan. 5. Fan installation: Exercise caution as follows when installing a fan on a panel or elsewhere. 1) Clamping of both flanges: The permissible tightening torque of M4 screws is 8 kgf・cm with an AC fan that has a metal venturi and up to 10 kgf・cm with a DC fan that has fan ribs. Through screws are not acceptable for the DC flange type. Use reinforcing spacers (for the KUDC and CNDC series) to tighten the double flanges on these products. (See page G-73.) 2) Clamping of single flange: The permissible tightening torque of screws when the installation surface is flat is 10 kgf・cm to 14 kgf・cm for both AC and DC fans. 3) Avoid contact with a propeller or impeller when mounting the intake side of fans and blowers. Excessive screw tightening will result in contact with a deformed venturi or housing. Technical Data Fans & Blowers Fans & Blowers Operational and handling precautions Blowers with Sensors φD AC/DC Axial Fans & Blowers m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB Speed min−1 1.8 64 72 0.29 39 3500 1.65 58 60 0.24 36 3150 1.45 51 45 0.18 34 2900 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 1.3 Max. airflow: 1.8 m3/min Max. static pressure: 72 Pa Mass: 115 g 46 35 0.14 31 34 22 0.09 24 460 SKUD24U7 3.2 12 7.2-13.8 270 690 SKUD12H7 3.6 24 12-27.6 150 350 SKUD24H7 3 12 7.2-13.8 250 550 SKUD12Z7 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. 3.3 24 12-27.6 140 320 SKUD24Z7 ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. 48 24-55.2 70 150 SKUD48Z7 12 7.2-13.8 230 480 SKUD12B4 24 12-27.6 130 240 SKUD24B4 48 24-55.2 60 130 SKUD48B4 12 8.4-13.8 110 240 SKUD12D4 24 14.4-27.6 60 110 SKUD24D4 -20 ∼ +60 SKUD12H7S SKUD12U7 SKUD12U7P SKUD12U7S Static pressure 60 SKLD24B4S SKLD12Z7S SKLD24B4 SKUD24B4P SKUD24B4S SKUD24D4 ■ External dimensions in mm (inches) ● Lead wire type SKUD...B4 SKUD...D4 30 4-φ 20 10 SKUD24D4P SKUD24H7 0.4 0.8 1.2 1.6 Rotation 2.0 Airflow (m3/mi n) 570 SKLD12B4 140 SKLD24B4 Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset SKUD24H7S -20 ∼ +70 25.5±0.5 (1±0.02) 10 (0.39) 5 (0.20) 8 4-φ 4.5±0.3 (4-0.18 dia.) ■ External dimensions in mm (inches) ● Lead wire type [By double chamber method] □92±1 (3.62 sq.) □82.5±0.3 (3.248 sq.±0.012) (Pa) 100 300±30 (11.8±1.2) 32±0.5 (1.26±0.02) 10 (0.39) 5 (0.20) 80 SKLD...Z7 60 40 SKLD...B4 0 0 0.5 1.0 1.5 Airflow (m3/mi n) 4-φ 4.5±0.3 (4-0.18 dia.) Rotation 2.0 Airflow Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black ■ Mounting hole dimensions in mm (inches) [Recommendation] ■ Wiring connection diagram □89 (3.5 sq.) Power source (+): Red □82.5 (3.248 sq.) Sensor output: Yellow Airflow 4 ) 10 ia. φ .1 d 4 ( Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (SKUD□D4: Blue) SKUD24H7P When sensor is installed ■ Mounting hole dimensions in mm (inches) [Recommendation] ■ Wiring connection diagram SKUD24Z7 Power source (-): Black □89 (3.50 sq.) □82.5 (3.248 sq.) SKUD24Z7S Sensor output: Yellow SKUD48B4 4 .) 10 ia φ 9d 0 . (4 SKUD48Z7 SKUD12Z7S SKUD12Z7P SKUD24Z7S SKUD24Z7P Rated Voltage SKUD12H7S SKUD12H7P SKUD24H7S SKUD24H7P SKUD12U7S SKUD12U7P ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. G-15 Options G-72, 73, 74 12 V 24 V Model Code SKLD12B4S SKLD24B4S SKLD12Z7S SKLD12Z7P SKLD24Z7S SKLD24Z7P ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. G-15 Options G-72, 73, 74 G-17 Options Options 24 V SKUD12B4S SKUD12B4P SKUD24B4S SKUD24B4P Centrifugal Centrifugal DC axial fan with sensor Model Code SKUD12D4S SKUD12D4P SKUD24D4S SKUD24D4P ・Filter: F92 filter ・Filter: F92 filter 4-φ 4.5 (4-0.18 dia.) DC axial fan with sensor 12 V Ensure the guard is situated more than 10 mm from the fan to minimize noise increase when mounting a guard on the intake side. See page G-10. Ensure the guard is situated more than 10 mm from the fan to minimize noise increase when mounting a guard on the intake side. See page G-10. Power source (-): Black or blue Rated Voltage Options (sold separately) ・Guard: F92UL guard Options (sold separately) ・Guard: F92UL guard When sensor is installed Outlet side 4-φ 4.5 (4-0.18 dia.) Outlet side Axial Power source (+): Red AC fans Axial AC fans SKUD24Z7P G-16 280 12-27.6 -20 ∼ +60 Silent Silent 0 0 SKUD24D4S 300±30 (11.8±1.2) SKUD...Z7 40 7.2-13.8 24 Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing 20 □92±1 (3.62 sq.) □82.5±0.3 (3.248 sq.±0.012) 12 3.5 Materials Used SKLD24Z7 SKUD...H7 50 3200 480 SKLD24Z7 Centrifugal Centrifugal 70 SKUD24B4 35 960 SKLD12Z7 150 ■ Standard airflow and static pressure characteristics (At rated voltage) SKLD24Z7S SKUD12Z7S 0.26 340 12-27.6 Standard Carton 60 to a carton of (450 x 380 x 300) mm, mass 10 kg Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset SKUD...U7 65 7.2-13.8 24 SKLD12Z7 Standard Carton 70 to a carton of (450 x 380 x 300) mm, mass 9 kg SKUD12Z7P 53 12 Common Elec. Spec. See pages G-11, G-12, G-13. SKLD24Z7P (Pa) 80 1.5 4 3.6 SKLD12B4S SKLD12Z7P [By double chamber method] 3800 Fan model code SKLD12B4 Common Elec. Spec. See pages G-11, G-12, G-13. SKUD12Z7 SKUD24U7 Max. airflow: 1.7 m3/min Max. static pressure: 86 Pa Mass: 150 g Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing ■ Standard airflow and static pressure characteristics (At rated voltage) 41 Axial SKUD12H7P Motor 0.35 DC fans Axial DC fans SKUD12H7 86 □92×32 (□3.6"×1.3") -20 ∼ +70 ■ General specification SKUD12D4S 60 ■ General specification φ 100±1 (3.94 dia.) SKUD12D4P 1.7 Operating Temp. Range ℃ Silent Silent 880 SKUD12U7 200 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. Materials Used Model Code 350 ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. SKUD12D4 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 12-27.6 SKUD12B4 SKUD12B4S Speed min−1 7.2-13.8 Fan model code SKUD12B4P Max. Airflow Max. Static Pressure Noise Pa inH2O dB 24 1.4 1950 m3/min CFM 12 2.8 0.95 DC MOLD SILENT 4.8 2.9 2600 ■ Standard specification 4.2 3.5 □92×25 (□3.6"×1.0") Operating Temp. Range ℃ Model Code DC Silent Fan φ 100±1 (3.94 dia.) DC MOLD SILENT □ 92 × φ100 × 32 mm 8 ■ Standard specification SKLD series 4-φ DC Silent Fan □ 92 × φ100 × 25 mm Static pressure SKUD series Brushless DC Fans & Blowers Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers SCUDM series DC Silent Fan ■ Standard specification DC MOLD SILENT m3/min CFM □ 120 × φ128 × 25 mm Max. Airflow Max. Static Pressure Noise Pa inH2O dB Speed min−1 57 2650 2.4 85 1.7 0.23 33 60 0.13 40 31 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 4.5 1950 2 Operating Temp. Range ℃ Model Code 12 7.2-13.8 380 740 SCUDM12B4 24 12-27.6 200 390 SCUDM24B4 12 8.4-13.8 170 380 SCUDM12D4 24 14.4-27.6 90 SCUDM24D4 Brushless DC Fans & Blowers SCUD series DC Silent Fan ■ Standard specification DC SILENT 25 m3/min CFM 0.23 39 4.5 1.7 33 60 0.13 31 1950 2 12 7.2-13.8 380 740 SCUD12B4 24 12-27.6 200 390 SCUD24B4 12 8.4-13.8 170 380 SCUD12D4 24 14.4-27.6 90 SCUD24D4 -20 ∼ +60 ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. ●Fan mounting Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing □120×25 (□4.7"×1.0") Max. airflow: 2.4 m3/min Max. static pressure: 57 Pa Mass: 230 g M4 nut Venturi SCUDM12B4S Standard Carton 60 to a carton of (450 x 380 x 300) mm, mass 12 kg Fan model code SCUD12B4 User panel or guard SCUD12B4P Nut pocket SCUDM12D4 SCUD12B4S SCUD12B4SQ M4 nut pockets provided in 4 places for easy mounting. (The customer to provide nuts) SCUDM12D4P □104.8±0.3 (4.126 sq.±0.012) 80 Detail of Part L SCUD24B4S 5 (0.20) 10 (0.39) SCUDM...B4 300±30 (11.8±1.2) 40 SCUD24D4 SCUD24D4S L 60 ■ Standard airflow and static pressure characteristics (At rated voltage) 1 ● Lead wire type □120 (4.73 sq.) (Pa) □104.8±0.3 (4.126 sq.±0.012) 80 3 Rotation φ SCUD...B4 20 0 SCUD...D4 0 1 2 Airflow (m3/mi n) 3 4-φ 4.5 (4-0.18 dia.) Sensor output: Yellow ■ Mounting hole dimensions in mm (inches) [Recommendation] □117 (4.61 sq.) Power source (+): Red □104.8 (4.126 sq.) □117 (4.61 sq.) □104.8 (4.126 sq.) Ensure the guard is situated more than 10 mm from the fan to minimize noise increase when mounting a guard on the intake side. See page G-10. 8 12 ia.) φ 4d 0 . (5 When sensor is installed Power source (-): Black or blue ・Filter: F120 filter Power source (-): Black or blue Outlet side 4-φ 4.5 (4-0.18 dia.) Rated Voltage 12 V 24 V Model Code SCUDM12D4S SCUDM12D4P SCUDM24D4S ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). G-18 Sensor Spec. G-15 Options G-72, 73, 74 DC axial fan with sensor Rated Voltage Model Code SCUD12D4S 12 V 24 V SCUD24D4S SCUD12B4S SCUD12B4P SCUD12B4SQ SCUD24B4S SCUD24B4P ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. G-15 Options G-72, 73, 74 G-19 Options Options SCUDM12B4S SCUDM12B4P SCUDM24B4S SCUDM24B4Q Centrifugal Centrifugal DC axial fan with sensor 4-φ 4.5 (4-0.18 dia.) Options (sold separately) ・Guard: F120UL guard (Outlet side) ・Guard: SCU guard (Intake side) Outlet side Axial 8 12 a.) φ 4 di 0 . (5 Sensor output: Yellow Options (sold separately) ・Guard: F120UL guard AC fans Axial AC fans When sensor is installed ■ Mounting hole dimensions in mm (inches) [Recommendation] ■ Wiring connection diagram Silent Power source (+): Red Lug for guard mounting Airflow Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (SCUD□D4: Blue) Airflow Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (SCUDM□D4: Blue) 9 Silent ■ Wiring connection diagram 4-φ 4.5±0.3 (4-0.18 dia) 10 (0.39) 4 (0.16) 40 (Nut pocket) 2 Airflow (m3/mi n) 25.5±0.5 (1±0.02) 60 Rotation SCUDM...D4 0 ■ External dimensions in mm (inches) [By double chamber method] 20 0 The guard for the intake side (SCU guard) can be mounted with one touch without using a tool. Centrifugal Centrifugal Static pressure SCUDM24D4S SCUD24B4P 25.5±0.5 (1±0.02) φ 128±1 (5.04 dia.) SCUDM24D4 (Nut pocket) Standard Carton 30 to a carton of (450 x 380 x 160) mm, mass 7.5 kg Axial □120±1 (4.73 sq.) Common Elec. Spec. See pages G-11, G-12, G-13. SCUD24B4 ● Lead wire type (Pa) Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset SCUD12D4S ■ External dimensions in mm (inches) [By double chamber method] SCUDM24B4S Motor DC fans Axial DC fans ■ Standard airflow and static pressure characteristics (At rated voltage) SCUD12D4 Materials Used Silent Silent Common Elec. Spec. See pages G-11, G-12, G-13. Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset ●Guard mounting Venturi: Aluminum alloy die castings Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing φ 128 (5.04) Materials Used ■ General specification 300±30 (11.8±1.2) ■ General specification SCUDM12B4P SCUDM24B4Q 2650 85 Operating Temp. Range ℃ Model Code ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. Motor SCUDM24B4 57 2.4 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. Fan model code SCUDM12B4 SCUDM12D4S Speed min−1 Static pressure Max. airflow: 2.4 m3/min Max. static pressure: 57 Pa Mass: 175 g Max. Airflow Max. Static Pressure Noise Pa inH2O dB -20 ∼ +60 ● The life expectancy of SCUDM-B speed products at rated voltage and in continuous operation is 20,000 hours at 60℃. (40,000 hours for other products) □120×25 (□4.7"×1.0") □ 120 × φ128 × 25 mm Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers DC MOLD SILENT m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB Speed min−1 95 3200 3.5 124 3 0.38 0.26 64 106 46 40 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 39 78 0.16 30 DC Silent Fan ■ Standard specification DC SILENT m3/min CFM SCNDM48B4 12 8.4-13.8 230 630 SCNDM12D4 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. 24 14.4-27.6 130 310 SCNDM24D4 ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. 1950 3 ●Fan mounting SCND12B4 Venturi SCND12B4Q SCND12B4S SCND12B4SQ User panel or guard SCND12D4 2 3 Airflow (m3/mi n) 2.2 78 39 0.16 30 1950 3 ■ General specification SCND12Z7SQ SCND24B4 SCND24B4Q SCND24B4S SCND24B4SQ 4 Venturi: Aluminum alloy die castings Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset Airflow ■ Wiring connection diagram Power source (+): Red The guard for the intake side (SCU guard) can be mounted with one touch without using a tool. Standard Carton 20 to a carton of (450 x 310 x 160) mm, mass 7.5 kg ■ Standard airflow and static pressure characteristics (At rated voltage) ■ External dimensions in mm (inches) ● Lead wire type □120 (4.73 sq.) □104.8±0.3 (4.126 sq.±0.012) SCNDM...Z7 80 60 20 SCNDM...D4 0 0 1 2 3 Airflow (m3/mi n) SCND24Z7 ■ Mounting hole dimensions in mm (inches) [Recommendation] ■ Wiring connection diagram Power source (+): Red □116 (4.61 sq.) □104.8 (4.126 sq.) Sensor output: Yellow 4 13 ia.) φ 8d .2 (5 When sensor is installed Ensure the guard is situated more than 10 mm from the fan to minimize noise increase when mounting a guard on the intake side. See page G-10. Power source (-): Black or blue ・Filter: F120 filter Axial Power source (-): Black or blue Options (sold separately) ・Guard: F120UL guard Options (sold separately) ・Guard: F120UL guard (Outlet side) SCN guard (Intake side) AC fans Axial AC fans When sensor is installed Lug for guard mounting Airflow Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (SCND□D4: Blue) SCND24Z7P □116 (4.61 sq.) 4 13 ia.) φ 8d 2 . (5 10 (0.39) 4 4-φ 4.5 (4-0.18 dia.) Rotation ■ Mounting hole dimensions in mm (inches) [Recommendation] □104.8 (4.126 sq.) Sensor output: Yellow 4 (0.16) SCNDM...B4 SCND24D4S SCND24Z7S 38.5±0.5 (1.52±0.02) 40 φ 9 Rotation Common Elec. Spec. See pages G-11, G-12, G-13. SCND24D4Q SCND24Z7Q (Nut pocket) ●Guard mounting Materials Used (Pa) 100 -20 ∼ +70 Silent Silent 1 7 SCND12D4SQ SCND24D4 4-φ 4.5±0.3 (4-0.18 dia.) φ 128±1 (5.04 dia.) Static pressure L 38.5±0.5 (1.52±0.02) 5 10 (0.20) (0.39) SCNDM...D4 0 2650 [By double chamber method] SCND12Z7S Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (SCNDM□D4: Blue) 20 0 40 Centrifugal Detail of Part L 40 0.26 Axial Centrifugal SCNDM48Z7 64 SCND12D4S SCND12Z7 ■ External dimensions in mm (inches) □120±1 (4.73 sq.) 300±30 □104.8±0.3 (4.126 sq.±0.012) (11.8 sq.±1.2) SCNDM...B4 106 DC fans Axial DC fans SCND12D4P Nut pocket (Nut pocket) SCNDM...Z7 3200 3 Fan model code M4 nut ● Lead wire type 46 0.38 -20 ∼ +70 Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset 60 310 SCND24D4 560 SCNDM24B4 120 (Pa) 100 SCNDM48B4 630 SCND12D4 130 320 24-55.2 [By double chamber method] SCNDM24Z7S 230 12-27.6 48 2650 Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing 80 8.4-13.8 24 14.4-27.6 24 7 ■ Standard airflow and static pressure characteristics (At rated voltage) SCNDM24Z7P 12 1050 SCNDM12B4 M4 nut pockets provided in 4 places for easy mounting. (The customer to provide nuts) SCNDM24Z7 560 SCND24B4 500 Standard Carton 40 to a carton of (450 x 380 x 300) mm, mass 12 kg SCNDM24D4S 320 7.2-13.8 95 124 Silent Silent SCNDM24D4Q 12-27.6 12 SCNDM24B4Q SCNDM24D4 1050 SCND12B4 24 SCNDM48Z7 SCNDM24B4 SCNDM24B4S 500 210 Common Elec. Spec. See pages G-11, G-12, G-13. SCNDM12Z7S 7.2-13.8 24-55.2 ■ General specification SCNDM12Z7 1200 SCND24Z7 12 48 Max. airflow: 3.5 m3/min Max. static pressure: 95 Pa Mass: 360 g SCNDM12D4S 2350 SCND12Z7 370 10 ● The life expectancy of SCNDM-B speed products at rated voltage and in continuous operation is 30,000 hours at 60 ℃. (40,000 hours for other products) Motor 710 12-27.6 1200 SCNDM24Z7 □120×38 (□4.7"×1.5") SCNDM12D4 7.2-13.8 24 2350 SCNDM12Z7 370 ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. SCNDM12B4S 12 9 710 12-27.6 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. SCNDM12B4 8.6 7.2-13.8 24 3.5 Operating Temp. Range ℃ Model Code 12 Max. airflow: 3.5 m3/min Max. static pressure: 95 Pa Mass: 250 g Materials Used Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Speed min−1 9 □120×38 (□4.7"×1.5") Fan model code Max. airflow Max. Static Pressure Noise Pa inH2O dB 8.6 6 2.2 Operating Temp. Range ℃ Model Code □ 120 × φ128 × 38 mm 128 (5.04) ■ Standard specification SCND series 300±30 (11.8±1.2) DC Silent Fan □ 120 × φ128 × 38 mm Static pressure SCNDM series Brushless DC Fans & Blowers Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers 4-φ 4.5 (4-0.18 dia.) Outlet side Outlet side DC axial fan with sensor Rated Voltage 12 V SCNDM24B4Q Options G-15 Options G-72, 73, 74 24 V Model Code SCND12D4S SCND12D4P SCND12D4SQ SCND24D4S SCND12B4S SCND12B4Q SCND12B4SQ SCND24B4S SCND24D4Q SCND24B4Q SCND24B4SQ SCND12Z7S SCND12Z7SQ SCND24Z7S SCND24Z7P SCND24Z7Q ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. G-15 Options G-72, 73, 74 G-21 Options SCNDM24D4Q SCNDM12Z7S SCNDM24Z7S SCNDM24Z7P ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. Rated Voltage Model Code SCNDM12B4S SCNDM24B4S 24 V G-20 DC axial fan with sensor 12 V SCNDM12D4S SCNDM24D4S Centrifugal Centrifugal 4-φ 4.5 (4-0.18 dia.) Brushless DC Fans & Blowers DC Axial Fan D0410C series ■ Standard specification DC Axial Fan ■ Standard specification D0410C m3/min CFM DC ELFIN 13 Max. Airflow Max. Static Pressure Noise Pa inH2O dB m3/min CFM 0.23 8.1 79 0.32 Speed min−1 37 9000 0.18 6.4 59 0.24 30 7200 0.12 4.2 30 0.12 26 5200 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 1.5 12 7.2-13.8 130 Operating Temp. Range ℃ Model Code -20 ∼ +70 270 EUDC12Z8 0.9 12 7.2-13.8 75 190 EUDC12B8 1.1 24 14.4-27.6 50 100 EUDC24B8 0.5 12 8.4-13.8 40 90 Max. Airflow Max. Static Pressure Noise Pa inH2O dB 320 +300 (12.6+1.2 ) 0 40 30 20 D0428C EUDC...Z8 EUDC...B8 D0428C series □ 40 × 28 mm ■ Standard specification Max. Airflow Max. Static Pressure Noise Pa inH2O dB m3/min CFM Speed min−1 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Rotation 5 4.5-5.5 680 950 D0428C05B7AZ-00 7-13.8 195 600 D0428C12B7AZ-00 2.28 24 12-27.6 95 310 D0428C24B7AZ-00 3.4 Sensor output: Yellow When sensor is installed Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black ■ Mounting hole dimensions in mm (inches) [Recommendation] 0.32 Max. airflow: 0.32 m3/min Max. static pressure: 103 Pa Mass: 52 g 0.41 37 8700 ■ Standard airflow and static pressure characteristics (At rated voltage) ■ External dimensions in mm (inches) ● Lead wire type [By double chamber method] Fan model code 4-φ 3.5 (4-0.14 dia.) Rotation 0.1 0.2 Lead wire spec. AWG24 UL1007 Color (+) Red ( - ) Black 0.3 G-15 ■ Mounting hole dimensions in mm (inches) [Recommendation] □39 (1.54 dia.) □32 (1.26) (□15) EUDC12B8S EUDC24B8S 38 .5 (1 .5 2) EUDC12D8S Options Options Sensor Spec. Airflow Model Code ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). G-22 4-φ 3.5±0.3 (4-0.14 dia.) Centrifugal Centrifugal 12 V 24 V Power source (-): Black 4 (0.16) 320 (12.6 ) Common to D0410C/D0428C Series ■ Wiring connection diagram Rated Voltage 4 (0.16) +30 0 +1.2 0 Airflow (m3/mi n) Power source (+): Red 28±0.5 (1.102±0.02) □32±0.3 (1.26 sq.±0.008) Axial 110 100 90 80 70 60 50 40 30 20 10 0 AC fans Axial AC fans Power source (-): Black or blue □40 (1.58 sq.) (Pa) D0428C12B7AZ-00 DC axial fan with sensor -10 ∼ +60 ● The characteristics are the values at rated voltage (5 V, 12 V or 24 V), and normal temperature and humidity. D0428C24B7AZ-00 8 φ 3 dia.) 5 (1. 103 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. □40×28 (□1.6"×1.1") D0428C05B7AZ-00 □ 32 (1.26 sq.) 11 Operating Temp. Range ℃ Silent Silent Power source (+): Red Airflow Static pressure ■ Wiring connection diagram 0.3 4-φ 3.5±0.3 (4-0.14 dia.) Model Code 2.34 12 EUDC...D8 0.1 0.2 Airflow (m3/mi n) Lead wire spec. AWG24 UL1007 Color (+) Red ( - ) Black 0.2 Centrifugal Static pressure 0.1 Airflow (m3/mi n) Airflow Axial Centrifugal 110 100 90 80 70 60 50 40 30 20 10 0 DC axial fan 4-φ 3.5±0.3 (4-0.14 dia.) Rotation DC fans Axial DC fans +1 +0.04 12.7 (0.5 ) 0 0 (Pa) +1 10 0 (0.4 +0.04 0 ) 3 3 (0.12) (0.12) (1.26 sq.±0.008) ● Lead wire type [By double chamber method] EUDC24B8S □40 +10 (1.58 sq.) EUDC24B8 ● Lead wire type □32±0.3 ■ External dimensions in mm (inches) □32±0.2 (1.26 sq.±0.008) EUDC12Z8 -10 ∼ +60 ■ External dimensions in mm (inches) □40 (1.58 sq.) 0 ■ Standard airflow and static pressure characteristics (At rated voltage) 100 D0410C12B7AZ-00 10 300±30 (11.8±1.2) EUDC12D8S D0410C05B7AZ-00 D0410C12B7AZ-00 Standard Carton 400 to a carton of (450 x 380 x 300) mm, mass 12 kg 250 D0410C05B7AZ-00 70 50 Fan model code Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset EUDC12D8 160 60 Max. airflow: 0.15 m3/min Max. static pressure: 41 Pa Mass: 19 g Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Common Elec. Spec. See pages G-11, G-12, G-13. 4.5-5.5 7.0-13.8 (Pa) □40×10 (□1.6"×0.4") EUDC12B8S 0.8 [By double chamber method] Static pressure EUDC12B8 5 0.84 12 Silent Silent Motor 6200 ■ Standard airflow and static pressure characteristics (At rated voltage) ■ General specification Fan model code 25 Operating Temp. Range ℃ Model Code ● The characteristics are the values at rated voltage (5 V or 12 V), and normal temperature and humidity. ● The life expectancy of EUDC12Z8 at rated voltage and in continuous operation is 30,000 hours at 60 ℃. (40,000 hours for other products at 60 ℃) Materials Used 0.16 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting EUDC12D8 ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. Max. airflow: 0.23 m3/min Max. static pressure: 79 Pa Mass: 26 g 41 Speed min−1 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. -20 ∼ +80 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. □40×13 (□1.6"×0.5") 5.3 0.15 □ 40 × 10 mm Fans & Blowers Fans & Blowers EUDC series □ 40 × 13mm Brushless DC Fans & Blowers Identical for the intake and outlet sides 4-φ 3.7 (4-0.15 dia.) G-23 D0515C series DC Axial Fan ■ Standard specification D0515C m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB 0.26 9.2 32 0.13 27 □ 52 × 15 mm Speed min−1 4600 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 1.2 Model Code 12 7-13.8 100 270 D0515C12B7AZ-00 24 14-27.6 50 140 D0515C24B7AZ-00 Operating Temp. Range ℃ Brushless DC Fans & Blowers TUDC series DC Axial Fan ■ Standard specification DC TINY 25 III m3/min CFM -10 ∼ +60 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. □ 60 × 25 mm Max. Airflow Max. Static Pressure Noise Pa inH2O dB Speed min−1 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 0.87 31 130 0.52 46 6800 4.2 0.74 26 100 0.40 39 5700 2.5 ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. ■ Standard airflow and static pressure characteristics (At rated voltage) ■ External dimensions in mm (inches) 0.65 23 75 0.30 37 5000 2.6 2.5 ● Lead wire type [By double chamber method] 0.55 □60×25 (□2.4"×1.0") Max. airflow: 0.26 m3/min Max. static pressure: 32 Pa Mass: 55 g Max. airflow: 0.87 m3/min Max. static pressure: 130 Pa Mass: 75 g Fan model code D0515C12B7AZ-00 Fan model code 19 59 0.24 32 4300 2.1 0.47 17 39 0.16 27 3650 1.4 1.8 Silent D0515C24B7AZ-00 Lead wire spec. AWG24 UL1007 Color (+) Red ( - ) Black ■ Standard specification Speed min−1 0.42 15 32 0.13 31 4200 0.55 19 53 0.21 41 5600 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Model Code 1.56 12 10.2-13.8 130 300 D0620C12B7AZ-00 1.68 24 20.4-27.6 70 240 D0620C24B7AZ-00 70 220 D0620C48B7AZ-00 3.36 48 43-53 Operating Temp. Range ℃ -10∼+60 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. □60×20 (□2.4"×0.8") ■ Standard airflow and static pressure characteristics (At rated voltage) ■ External dimensions in mm (inches) ● Lead wire type [By double chamber method] Fan model code D0620C12B7AZ-00 D0620C24B7AZ-00 D0620C48B7AZ-00 12-27.6 110 48 24-55.2 50 12 7.2-13.8 140 24 12-27.6 80 48 24-55.2 40 12 7.2-13.8 130 24 12-27.6 70 48 24-55.2 40 12 8.4-13.8 80 24 14.4-27.6 40 -20 ∼ +60 TUDC48H4 550 TUDC12Z4F TUDC12Z4 270 TUDC24Z4F TUDC24Z4 TUDC48Z4 380 TUDC12B4F TUDC12B4 190 TUDC24B4F TUDC24B4 -20 ∼ +70 TUDC48B4 210 TUDC12D4F TUDC12D4 110 TUDC24D4F TUDC24D4 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. ■ General specification Materials Used Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset Common Elec. Spec. See pages G-11, G-12, G-13. Standard Carton 100 to a carton of (450 x 380 x 160) mm, mass 9 kg ■ Standard airflow and static pressure characteristics (At rated voltage) Specify no suffix symbol in your ordering information when the venturi is mounted with screws. Suffix 'F' for an open flange venturi. ■ External dimensions in mm (inches) ● Lead wire type [By double chamber method] Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (TUDC□D4: Blue) ■ Mounting hole dimensions in mm (inches) [Recommendation] ■ Wiring connection diagram Options (sold separately) ・Guard: F60UL guard P60P guard DC axial fan with sensor Rated Vol. 12 V Model Code TUDC12D4S TUDC12D4FS TUDC24D4S TUDC12B4S TUDC12B4P TUDC24B4S 24 V 48 V TUDC48B4S TUDC48B4P TUDC12Z4S TUDC12Z4FS TUDC12Z4P TUDC24Z4S TUDC24Z4SQ TUDC24Z4FS TUDC24Z4P TUDC48Z4FS TUDC48Z4P TUDC48Z4FP TUDC12H4S TUDC12H4SF TUDC12H4P TUDC24H4S TUDC12U7S TUDC12U7P TUDC12N7P TUDC24N7S TUDC24N7P TUDC24H4P TUDC48H4P ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● Customizing to the sleeve bearing specification also accepted depending on the intended purchase quantity. Contact Japan Servo for further information. ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. G-15 Options G-72, 73, 74 G-25 Options G-24 63 ) a. di 24 710 TUDC12H4F TUDC12H4 360 TUDC24H4F TUDC24H4 Centrifugal Options φ 8 .4 (2 0.9 220 Axial Centrifugal Common to D515C/D0620C Series ■ Wiring connection ■ Mounting hole dimensions in mm (inches) [Recommendation] diagram ● D0515C series ● D0620C series 2750 210 7.2-13.8 AC fans Axial AC fans Lead wire spec. AWG24 UL1007 Color (+) Red ( - ) Black 20 6-13.8 12 Silent Silent Max. airflow: 0.55 m3/min Max. static pressure: 53 Pa Mass: 90 g 0.10 12 1430 TUDC12N7F TUDC12N7 700 TUDC24N7F TUDC24N7 790 TUDC12U7F TUDC12U7 Centrifugal Centrifugal Max. Airflow Max. Static Pressure Noise Pa inH2O dB m3/min CFM 24 170 Axial D0620C D0620C series □ 60 × 20 mm 12 350 12-27.6 Operating Temp. Range ℃ DC fans Axial DC fans DC axial fan TUDC12B4 TUDC12B4F TUDC12B4P TUDC12B4S TUDC12D4 TUDC12D4F TUDC12D4FS TUDC12D4S TUDC12H4 TUDC12H4F TUDC12H4FS TUDC12H4P TUDC12H4S TUDC12N7 TUDC12N7F TUDC12N7P TUDC12U7 TUDC12U7F TUDC12U7P TUDC12U7S TUDC12Z4 TUDC12Z4F TUDC12Z4FS TUDC12Z4P TUDC12Z4S TUDC24B4 TUDC24B4F TUDC24B4S TUDC24D4 TUDC24D4F TUDC24D4S TUDC24H4 TUDC24H4F TUDC24H4P TUDC24H4S TUDC24N7 TUDC24N7F TUDC24N7P TUDC24N7S TUDC24Z4 TUDC24Z4F TUDC24Z4FS TUDC24Z4P TUDC24Z4S TUDC24Z4SQ TUDC48B4 TUDC48B4P TUDC48B4S TUDC48H4 TUDC48H4P TUDC48Z4 TUDC48Z4F TUDC48Z4FP TUDC48Z4FS TUDC48Z4P 0.35 7.2-13.8 24 Ribbed Flange Silent □52×15 (□2.0"×0.6") 1.8 12 Model Code Open Flange Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers DC Axial Fan ■ Standard specification DC PIXIE 25 III m3/min CFM □ 80 × 25 mm Max. Airflow Max. Static Pressure Noise Pa inH2O dB 1.58 56 1.32 100 47 0.40 74 Speed min−1 47 0.30 40 4560 3900 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 42 59 0.24 35 3500 12 7.2-13.8 340 1080 PUDC12U7 PUDC12U7R 24 12-27.6 190 510 PUDC24U7 PUDC24U7R 12 7.2-13.8 320 730 PUDC12H4 PUDC12H4R -20 ∼ +60 3.8 2.4 Max. airflow: 1.58 m3/min Max. static pressure: 100 Pa Mass: 85 g 0.94 33 38 0.15 30 2800 1.5 1.8 26 25 0.10 23 2150 1 Fan model code Max. Airflow Max. Static Pressure Noise m3/min CFM Pa inH2O dB 32 29.4 0.12 Speed min−1 31 3100 Input Voltage spec. V Current mA Model Code W Rating Operating Range Rating Starting 12 7.2-13.8 200 370 D0815C12B7AZ-00 2.4 24 14-27.6 100 154 D0815C24B7AZ-00 Operating Temp. Range ℃ -10 ∼ +60 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. ■ Standard airflow and static pressure characteristics (At rated voltage) 24 12-27.6 160 340 PUDC24H4 48 24-55.2 70 PUDC48H4 12 7.2-13.8 160 520 PUDC12Z4 PUDC12Z4R □80×15 (□3.2"×0.6") 24 12-27.6 100 200 PUDC24Z4 PUDC24Z4R 48 24-55.2 60 PUDC48Z4 Max. airflow: 0.91 m3/min Max. static pressure: 29.4 Pa Mass: 68 g 12 7.2-13.8 140 320 PUDC12B4 PUDC12B4R 24 12-27.6 70 180 PUDC24B4 PUDC24B4R 48 24-55.2 40 PUDC48B4 12 8.4-13.8 80 180 PUDC12D4 PUDC12D4R 24 14.4-27.6 40 PUDC24D4 PUDC24D4R PUDC24H4R -20 ∼ +70 ■ External dimensions in mm (inches) ● Lead wire type Lead wire spec. AWG24 UL1007 Color (+) Red ( - ) Black [By double chamber method] (Pa) 60 Fan model code D0815C12B7AZ-00 +1 0 15 (0.59 □80 (3.15 sq.) □71.5±0.3 (2.815 sq.±0.012) 40 3.5 (0.14) ) 3.5 (0.14) +30 300 0 (12 +1.2 0 ) 20 D0815C24B7AZ-00 +0.04 0 0 0 0.4 0.8 Airflow (m3/mi n) 1.2 4-φ 4.3±0.3 (4-0.18 dia.) Rotation Airflow ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. DC Axial Fan ●Venturi shape ■ General specification Materials Used Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset D0820C ■ Standard specification Max. Airflow Max. Static Pressure Noise m3/min CFM Pa inH2O dB 0.84 30 29.4 0.12 Speed min−1 31 2900 Input W 2.52 2.88 Voltage spec. V Current mA Model Code Rating Operating Range Rating Starting 12 10.2-13.8 210 280 D0820C12B7AZ-00 24 20.4-27.6 120 150 D0820C24B7AZ-00 Operating Temp. Range ℃ -10 ∼ +60 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. Open flange Ribbed flange Standard Carton 120 to a carton of (450 x 380 x 300) mm, mass 10 kg Use ribbed venturi with a reinforced corner when the venturi is mounted with screws. (The spacer is indicated in the model code by the letter 'R'.) ■ External dimensions in mm (inches) ● Lead wire type Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (PUDC□D4: Blue) [By double chamber method] (Pa) 100 □80±1 (3.15 sq.) □71.5±0.3 (2.815 sq.±0.012) PUDC...U7 PUDC...H4 PUDC...Z4 60 300±30 (11.8±1.2) 4 (0.16) 4 (0.16) Fan model code D0820C12B7AZ-00 PUDC...D4 40 30 20 30 + 0 300 +1 .2 ) 0 (12 10 0 0 0.4 Airflow (m3/mi n) 0.4 0.8 1.2 Airflow (m3/mi n) D0832C 1.6 8-φ 4.5±0.3 (8-0.18 dia.) Rotation ■ Wiring connection diagram Power source (+): Red ■ Mounting hole dimensions in mm (inches) [Recommendation] □ 71.5 (2.815 sq.) a φ di 3 .4 (3 When sensor is installed .) 4-φ 4.5 Identical for the intake (4-0.18 dia.) and outlet sides □80×32 (□3.2"×1.3") Fan model code 12 V 24 V D0832C24B7AZ-00 Model Code PUDC12D4S PUDC12D4RS PUDC24D4S PUDC24D4RS PUDC12B4S PUDC12B4RS PUDC12B4P PUDC12B4RP PUDC24B4S PUDC24B4RS PUDC48B4P Options G-72, 73, 74 37 43 0.17 33 3150 1.1 39 51 0.21 35 3350 Voltage spec. V Current mA Model Code Rating Operating Range Rating Starting 630 D0832C12B7AZ-00 12 10.2-13.8 160 300 D0832C24B7AZ-00 24 20.4-27.6 90 43-53 90 190 D0832C48B7AZ-00 48 Operating Temp. Range ℃ -10∼+60 ■ Standard airflow and static pressure characteristics (At rated voltage) ■ External dimensions in mm (inches) ● Lead wire type Lead wire spec. AWG24 UL1007 Color (+) Red ( - ) Black [By double chamber method] (Pa) 80 □80 (3.15 sq.) 60 32±0.5 (1.25±0.02) □71.5±0.3 (2.815 sq.±0.012) D0832C48B7 4 (0.16) 4 (0.16) D0832C12B7 D0832C24B7 40 300 (12) 20 +30 0 D0832C48B7AZ-00 PUDC12H4S PUDC12H4RS PUDC12H4P PUDC12H4RP PUDC24H4S PUDC24H4RS PUDC12U7S PUDC12U7RS PUDC12U7P PUDC12U7RP 0 0 0.4 0.8 Airflow (m3/mi n) 1.2 4-φ 4.3±0.3 (4-0.17) Rotation Airflow Common to D0815C/D0820C/D0832C Series ■ Mounting hole dimensions in mm (inches) [Recommendation] ■ Wiring connection ● D0815C series ● D0820C series ● D0832C series diagram PUDC48H4P ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● Customized fans with sleeve bearings are also available depending on the intended purchase quantity. Contact Japan Servo for further information. ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). G-15 1.05 Input W 1.92 2.16 2.88 Power source (+): Red □ 77 (3.03 sq.) □ 71.5 (2.815 sq.) φ 87 Power source (-): Black 4-φ 4.5 (4-0.18 dia.) Identical for the intake and outlet sides □78 (3.07 sq.) □78 (3.07 sq.) □78 (3.07 sq.) □78 (3.07 sq.) □71.5 (2.81 sq.) □71.5 (2.81 sq.) □71.5 (2.81 sq.) □71.5 (2.81 sq.) ).) aia. ddi 5522 33.. 5(( 5 . . 8899 φφ Outlet side 4-φ 4.5 (4-0.18 dia.) φ 88 6 .4 (3 ) a. di Intake side 4-φ 4.5 (4-0.18 dia.) .) aia) ddi 52 3. 5( 5 . . 9 889 φφ Outlet side 4-φ 4.5 (4-0.18 dia.) ).) aia. ddi 3311 33.. ( ( 8844 φφ Options Options 48 V PUDC12Z4S PUDC12Z4RS PUDC12Z4P PUDC12Z4RP PUDC24Z4Q PUDC24Z4S PUDC24Z4RS PUDC24Z4P PUDC48Z4S PUDC48Z4P Speed min−1 Centrifugal Centrifugal Rated Vol. Max. Airflow Max. Static Pressure Noise m3/min CFM Pa inH2O dB ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. D0832C12B7AZ-00 DC axial fan with sensor ■ Standard specification ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. Max. airflow: 1.1 m3/min Max. static pressure: 51 Pa Mass: 150 g Power source (-): Black or blue Airflow Axial 87 4-φ 4.3±0.3 (4-0.17) Rotation AC fans Axial AC fans Options (sold separately) ・Guard: F80UL guard ・Filter: F80 filter □ 77 (3.03 sq.) Sensor output: Yellow Airflow 0.8 Silent Silent 0 0 20-10 (0.787 -0.04 ) 3.5 3.5 (0.14) (0.14) D0820C24B7AZ-00 DC Axial Fan 20 Lead wire spec. AWG24 UL1007 Color (+) Red ( - ) Black □80 (3.15 sq.) □71.5±0.3 (2.815 sq.±0.012) PUDC...B4 0 Sensor Spec. (Pa) 40 Max. airflow: 0.84 m3/min Max. static pressure: 29.4 Pa Mass: 100 g Static pressure Static pressure 80 25.5±0.5 (1±0.02) ● Lead wire type Centrifugal ■ Standard airflow and static pressure characteristics (At rated voltage) □80×20 (□3.2"×0.8") ■ External dimensions in mm (inches) [By double chamber method] Static pressure Common Elec. Spec. See pages G-11, G-12, G-13. ■ Standard airflow and static pressure characteristics (At rated voltage) Axial Centrifugal G-26 D0815C DC fans Axial DC fans PUDC12B4 PUDC12B4P PUDC12B4R PUDC12B4RP PUDC12B4RS PUDC12B4S PUDC12D4 PUDC12D4R PUDC12D4RS PUDC12D4S PUDC12H4 PUDC12H4P PUDC12H4R PUDC12H4RP PUDC12H4RS PUDC12H4S PUDC12U7 PUDC12U7P PUDC12U7R PUDC12U7RP PUDC12U7RS PUDC12U7S PUDC12Z4 PUDC12Z4P PUDC12Z4R PUDC12Z4RP PUDC12Z4RS PUDC12Z4S PUDC24B4 PUDC24B4R PUDC24B4RS PUDC24B4S PUDC24D4 PUDC24D4R PUDC24D4RS PUDC24D4S PUDC24H4 PUDC24H4R PUDC24H4RS PUDC24H4S PUDC24U7 PUDC24U7R PUDC24Z4 PUDC24Z4P PUDC24Z4R PUDC24Z4RS PUDC24Z4S PUDC48B4 PUDC48B4P PUDC48H4 PUDC48H4P PUDC48Z4 PUDC48Z4P PUDC48Z4S ■ Standard specification Silent Silent 0.73 DC Axial Fan □ 80 × 15 mm / □ 80 × 20 mm / □ 80 × 32 mm 0.91 4 2.6 □80×25 (□3.2"×1.0") Operating Ribbed Flange Temp. Range ℃ 4.3 3.2 1.2 Model Code Open Flange D0815C / D0820C / D0832C series Static pressure PUDC series Brushless DC Fans & Blowers Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers 4-φ 4.5 (4-0.18 dia.) Intake side G-27 DC Axial Fan ■ Standard specification DC KOALA 25 m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB 64 1.8 Max. airflow: 1.8 m3/min Max. static pressure: 70 Pa Mass: 100 g 41.5 3450 60 0.24 39 3200 1.55 55 52 0.21 37 2950 49 43 35 0.17 24 34 0.10 26 2750 1950 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Model Code Open Flange With Spacer Operating Temp. Range ℃ D0925C series □ 92 × 25 mm Super Silent Fan ■ Standard specification * They are tentative values. D0925C m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB 12 7.2-13.8 350 880 KUDC12U7 KUDC12U7V 4.8 24 12-27.6 200 460 KUDC24U7 KUDC24U7V 3.2 12 7.2-13.8 270 690 KUDC12H7 KUDC12H7V 3.6 24 12-27.6 150 350 KUDC24H7 KUDC24H7V ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. 3.0 12 7.2-13.8 250 550 KUDC12Z7 KUDC12Z7V ● The characteristics are the values at rated voltage (12 V, 24 V, or 48 V), and normal temperature and humidity. 3.3 24 12-27.6 140 320 KUDC24Z7 KUDC24Z7V 3.5 48 24-55.2 70 150 KUDC48Z7 12 7.2-13.8 230 480 KUDC12B4 KUDC12B4V 24 12-27.6 130 240 KUDC24B4 KUDC24B4V □92×25 (□3.6"×1.0") Materials Used 48 24-55.2 60 130 KUDC48B4 KUDC12D4V Max. airflow: m3/min Max. static pressure: Pa Mass: g Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing KUDC24D4V Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset 2.9 1.4 12 8.4-13.8 110 240 KUDC12D4 1.3 24 14.4-27.6 60 110 KUDC24D4 D0925C12B8AZ-00 -20 ∼ +60 D0925C12B6AZ-00 D0925C12B4AZ-00 ● A ribbed flange only is available as the venturi shape of these products. ■ General specification -20 ∼ +70 Common Elec. Spec. See pages G-11, G-12, G-13. Fan model code ● The characteristics are the values at rated voltage (12 V, 24 V, or 48 V), and normal temperature and humidity. D0925C12B4AZ-00 ● The life expectancy of KUDC-U speed products at rated voltage and in continuous operation is 30,000 hours at 60 ℃. (40,000 hours for other products) ■ General specification ●Venturi shape ・ High airflow rate (Plan target m3/min or less) ● Lead wire type ・ Variable speed (PWM, voltage, resistance) available □92 (3.62 sq.) □82.5±0.3 (3.248 sq.±0.012) KUDC...U7 KUDC...H7 Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (KUDC□D4: Blue) 25.5±0.5 (1.0±0.02) 300±30 (11.8±1.2) 4 (0.16) 40 4 4 (0.16) D0925C...B4 20 Airflow 0 0.5 1.0 1.5 2.0 Airflow (m (m3/mi n) 4-φ4.5 Rotation 2.5 (4-0.18 dia.) Lead wire spec. AWG24 UL3266 Color (+) Red ( - ) Black ■ Mounting hole dimensions in mm (inches) [Recommendation] □89 (3.5 sq.) 1 Airflow (m3/mi n) 2 Rotation ■ Wiring connection diagram Power source (+): Red 4-φ 4.5 (4-0.18 dia.) Power source (-): Black 4 ) 10 ia. φ 1d . 4 ( □82.5 (3.248 sq.) ・Filter: F92 filter Identical for the intake and outlet sides 4-φ 4.5 (4-0.18 dia.) Axial 4 ) 10 ia. φ 1d . 4 ( Ensure the guard is situated more than 10 mm from the fan to minimize noise increase when mounting a guard on the intake side. See page G-9. AC fans Axial AC fans Options (sold separately) ・Guard: F92UL guard ・Filter: F92 filter ・Spacer: Flange spacer PUDC □89 (3.5 sq.) When sensor is installed Options (sold separately) ・Guard: F92UL guard Airflow ■ Mounting hole dimensions in mm (inches) [Recommendation] Sensor output: Yellow □82.5 (3.248 sq.) Silent Silent Power source (+): Red 0 ±0.5 (1.0±0.02) (3.248 sq.±0.012) D0925C...B6 KUDC...D4 20 ±0.3 D0925C...B8 60 ■ Wiring connection diagram KUDC...B4 □ 82.5 (0.16) 4 (0.16) KUDC...Z7 25 □92 (3.62 sq.) 30 Centrifugal Centrifugal ■ External dimensions in mm (inches) ・ Sensor (lock, pulse) can be installed (Pa) 80 Static pressure Flange with spacer 300 Axial Open flange Use the reinforced product with spacer when the venturi is mounted with screws. (The spacer is indicated in the model code by the letter 'V'.) ● Lead wire type (11.8±1.2) (Pa) 80 % ・ Motor vibration ■ External dimensions in mm (inches) DC fans Axial DC fans ・ Energy saving [By double chamber method] 40 [By double chamber method] ・ Noise at operating point (from KUDC fan) dB Standard Carton 70 to a carton of (450 x 380 x 300) mm, mass 7 kg 60 ■ Standard airflow and static pressure characteristics (At rated voltage) D0925C12B8AZ-00 ■ Features Common Elec. Spec. See pages G-11, G-12, G-13. ■ Standard airflow and static pressure characteristics (At rated voltage) D0925C12B6AZ-00 Spacer Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset Motor Operating Temp. Range ℃ Model Code 4.2 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. Materials Used Speed Voltage Spec. V Current mA min−1 Rating Operating Range Rating Starting Silent Silent Power source (-): Black or blue 4-φ 4.5 Identical for the intake (4-0.18 dia.) and outlet sides Product debut scheduled for spring of 2007 DC axial fan with sensor Rated Vol. Model Code KUDC12D4S 12 V KUDC12D4VP KUDC24D4S KUDC12B4S KUDC12B4VS KUDC12B4P KUDC24B4S 24 V KUDC12Z7S KUDC12Z7VS KUDC12Z7P KUDC12Z7VP KUDC24Z7S KUDC24Z7VS KUDC24Z7P KUDC12H7S KUDC12H7P KUDC12U7S KUDC12U7VS KUDC12U7P KUDC12U7VP KUDC24H7S KUDC24H7VS KUDC24H7P KUDC48Z7P ● Box-type silent axial fans with an innovative concept (design focusing on sound quality after embedding in equipment); optimizing all components by fully utilizing know-how in computational fluid dynamics (CFD). ● "Low Vibration Super Silent Fan" with a wide silent range, best fitting all applications and enhances the high added value of embedded equipment. ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● Tentative values are listed in this edition of the catalog. More products will be added to the series as they are prototyped. Contact Japan Servo for further information. ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). G-15 Options G-72, 73, 74 Options G-72, 73, 74 G-29 Options Options KUDC24B4P KUDC48B4S KUDC48B4VS KUDC48B4P 48 V Sensor Spec. Centrifugal Centrifugal G-28 0.28 59 1 Fan model code 70 Speed min−1 1.66 1.4 □92×25 (□3.6"×1.0") KUDC12B4 KUDC12B4P KUDC12B4S KUDC12B4V KUDC12B4VS KUDC12D4 KUDC12D4S KUDC12D4V KUDC12D4VP KUDC12H7 KUDC12H7P KUDC12H7S KUDC12H7V KUDC12U7 KUDC12U7P KUDC12U7S KUDC12U7V KUDC12U7VP KUDC12U7VS KUDC12Z7 KUDC12Z7P KUDC12Z7S KUDC12Z7V KUDC12Z7VP KUDC12Z7VS KUDC24B4 KUDC24B4P KUDC24B4S KUDC24B4V KUDC24D4 KUDC24D4S KUDC24D4V KUDC24H7 KUDC24H7P KUDC24H7S KUDC24H7V KUDC24H7VS KUDC24U7 KUDC24U7V KUDC24Z7 KUDC24Z7P KUDC24Z7S KUDC24Z7V KUDC24Z7VS KUDC48B4 KUDC48B4P KUDC48B4S KUDC48B4VS KUDC48Z7 KUDC48Z7P □ 92 × 25 mm Static pressure KUDC series Brushless DC Fans & Blowers Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers CUDC series DC Axial Fan ■ Standard specification DC Axial Fan ■ Standard specification DC KOALA III m3/min CFM DC CENTAUR 25 III m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB Speed min−1 2.1 74 140 0.56 48 4600 1.9 67 115 0.46 45 4150 1.7 86 60 1.5 0.35 0.26 65 53 43 39 3800 3200 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Model Code Open Flange Ribbed Flange 5.7 12 6-13.8 470 1700 KLDC12U7 6.2 24 12-27.6 260 870 KLDC24U7 4.6 24 12-27.6 190 690 KLDC24H7F KLDC24H7 4 12 7.2-13.8 340 960 KLDC12Z7F KLDC12Z7 3.6 24 12-27.6 150 480 KLDC24Z7F KLDC24Z7 12 7.2-13.8 280 570 KLDC12B4F KLDC12B4 24 12-27.6 140 KLDC24B4F KLDC24B4 3.5 Operating Temp. Range ℃ -20 ∼ +60 Fan model code Materials Used Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset KLDC12B4 KLDC12B4F KLDC12B4P KLDC12B4S KLDC12Z7FP ■ Standard airflow and static pressure characteristics (At rated voltage) KLDC24B4 100 Static pressure 120 KLDC24B4F KLDC24B4S KLDC24H7 KLDC24H7F KLDC...H7 KLDC...Z7 60 CUDC12B7S ● Lead wire type CUDC12D4 Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black 300±30 (11.8±1.2) 32±0.5 (1.26±0.02) KLDC...U7 CUDC12B7RS KLDC...B4 0.5 1.0 1.5 Airflow (m3/mi n) KLDC24Z7F 2.0 2.5 Rotation KLDC24Z7P Power source (+): Red KLDC24Z7S □82.5 (3.248 sq.) Sensor output: Yellow 140 450 CUDC48H7 3.4 12 6-13.8 280 740 CUDC12B7 CUDC12B7R 3.8 24 12-27.6 160 390 CUDC24B7 CUDC24B7R 12 8.4-13.8 160 380 CUDC12D4 CUDC12D4R 24 14.4-27.6 90 CUDC24D4 CUDC24D4R 2 Materials Used Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset Options (sold separately) ・Guard: F92UL guard ・Filter: F92 filter Open flange Common Elec. Spec. See pages G-11, G-12, G-13. Standard Carton 60 to a carton of (450 x 380 x 300) mm, mass 12 kg ■ Standard airflow and static pressure characteristics (At rated voltage) □120±1 (4.72 sq.) CUDC12D4R 120 CUDC...H7 80 CUDC...B7 60 40 CUDC12H7S 20 0 CUDC24B7P CUDC24B7RS □104.8±0.3 (4.126 sq.±0.012) 100 CUDC12H7P CUDC24B7R ● Lead wire type [By double chamber method] CUDC12D4Q CUDC12D4RQ ■ External dimensions in mm (inches) CUDC...D4 Rotation 0 1 2 3 Airflow (m3/mi n) CUDC24B7S Power source (+): Red □116 (4.61 sq.) □104.8 (4.126 sq.) Sensor output: Yellow KLDC24B4S G-15 CUDC24H7 Identical for the intake and outlet sides CUDC24H7P CUDC24H7S Options G-72, 73, 74 4-φ 4.5 (4-0.18 dia.) DC axial fan with sensor Model Code KLDC12U7P 12 V CUDC12D4S CUDC12D4RS CUDC12D4P CUDC12D4Q CUDC12D4RQ CUDC24D4S 24 V CUDC12B7S CUDC12B7RS CUDC12B7P CUDC12B7RP CUDC12H7S CUDC12H7P CUDC24B7S CUDC24B7RS CUDC24B7P CUDC24H7S CUDC24H7P CUDC24D4Q CUDC24D4SQ ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. G-15 Options G-72, 73, 74 G-31 Options Options Sensor Spec. Power source (-): Black or blue Rated Voltage ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). G-30 When sensor is installed CUDC24D4S Options (sold separately) ・Guard: F120UL guard ・Filter: F120 filter 8 ) . 12 φ dia .04 5 ( CUDC24D4RQ CUDC24D4RS Airflow ■ Mounting hole dimensions in mm (inches) [Recommendation] CUDC24D4 CUDC24D4Q 8-φ4. 5±0. 3 (8-0.18 dia.) Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (CUDC□D4: Blue) 4 ■ Wiring connection diagram Model Code 24 V 25.5±0.5 (1±0.02) (5) Centrifugal Centrifugal DC axial fan with sensor 12 V (5) Axial and outlet sides KLDC12Z7S KLDC12Z7FS KLDC12Z7P KLDC12Z7FP KLDC24Z7S KLDC24Z7FS KLDC24Z7P KLDC24Z7FP 300±30 (11.8±1.2) CUDC24D4SQ 4-φ 4.5 Identical for the intake (4-0.18 dia.) KLDC12B4S KLDC12B4P Ribbed flange AC fans Axial AC fans 4 ) 10 ia. φ 1d . (4 Power source (-): Black Rated Voltage -20 ∼ +60 Use ribbed venturi with a reinforced corner when the venturi is mounted with screws. (The spacer is indicated in the model code by the letter 'R'.) CUDC24D4R When sensor is installed -20 ∼ +70 ●Venturi shape Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing CUDC24B7 Airflow ■ Mounting hole dimensions in mm (inches) [Recommendation] □89 (3.5 sq.) 48 40.8-55.2 Silent Silent ■ Wiring connection diagram 4-φ 4.5±0.3 (4-0.18 dia.) 1180 CUDC24H7 6.7 ■ General specification (Pa) 140 CUDC12H7 0 2120 CUDC12H7 270 ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. CUDC12D4P CUDC12D4S 0 KLDC24Z7 540 1950 12 CUDC12B7RP CUDC12D4RS 40 20 KLDC24U7 KLDC24Z7FS ■ External dimensions in mm (inches) □82.5±0.3 (3.248 sq.±0.012) 80 CUDC12B7P CUDC12B7R □92±1 (3.62 sq.) 34 2650 8.4-13.8 24 19.2-27.6 6.5 Centrifugal Centrifugal KLDC12Z7S Ribbed flange Specify no suffix symbol in your ordering information when the venturi is mounted with screws. Suffix 'F' for an open flange venturi. (Pa) 140 KLDC12Z7P KLDC24Z7FP CUDC12B7 [By double chamber method] KLDC12Z7FS 0.14 42 3700 Operating Temp. Range ℃ Ribbed Flange Axial KLDC12Z7 0.24 50 Open Flange DC fans Axial DC fans KLDC12U7P KLDC12Z7F Max. airflow: 3.25 m3/min Max. static pressure: 125 Pa Mass: 180 g Fan model code Open flange Standard Carton 60 to a carton of (450 x 380 x 220) mm, mass 9 kg KLDC12U7 36 60 1.7 □120×25 (□4.7"×1.0") ●Venturi shape Common Elec. Spec. See pages G-11, G-12, G-13. 60 85 0.50 Model Code Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Silent Silent ■ General specification 125 Speed min−1 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. Max. airflow: 2.1 m3/min Max. static pressure: 140 Pa Mass: 145 g 115 2.4 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. □92×32 (□3.6"×1.3") Max. Airflow Max. Static Pressure Noise Pa inH2O dB 3.25 -20 ∼ +70 □ 120 × 25 mm Fans & Blowers Fans & Blowers KLDC series □ 92 × 32 mm Brushless DC Fans & Blowers Static pressure Brushless DC Fans & Blowers DC Axial Fan ■ Standard specification DC CENTAUR V Max. Airflow Max. Static Pressure Noise m3/min CFM Pa inH2O dB 4.4 155 4.0 141 3.5 □120×38 (□4.7"×1.5") 2.8 Max. airflow: 4.4 m3/min Max. static pressure: 160 Pa Mass: 250 g CNDC12B7 CNDC12B7P CNDC12B7S CNDC12D7 99 2.1 74 140 44 CNDC12Z7P CNDC12Z7S CNDC24B7 32 2650 1950 350 D1238T48B7AZ-00 7.5 12 8.4-13.8 630 1050 D1238T12B6AZ-00 8.5 48 33.6-55.2 180 330 D1238T48B6AZ-00 24 19.2-27.6 390 1970 CNDC24H7 8.6 12 7.2-13.8 710 2350 CNDC12Z7 24 12-27.6 370 1200 CNDC24Z7 10.0 48 24-55.2 210 530 CNDC48Z7 4.6 12 7.2-13.8 380 1330 CNDC12B7 4.8 24 12-27.6 200 640 CNDC24B7 9.0 6 48 24-55.2 120 340 CNDC48B7 2.4 12 8.4-13.8 200 CNDC12D7 2.6 24 14.4-27.6 110 CNDC24D7 Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset Common Elec. Spec. See pages G-11, G-12, G-13. Standard Carton 40 to a carton of (450 x 380 x 300) mm, mass 12 kg ■ Standard airflow and static pressure characteristics (At rated voltage) Open flange CNDC48Z7V -20 ∼ +70 □120×38 (□4.7"×1.5") CNDC12D7V Max. airflow: 4.4 m3/min Max. static pressure: 160 Pa Mass: 290 g (Pa) 160 CNDC...U7 140 Silent CNDC24D7 CNDC24D7P 120 Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (CNDC□D7: Blue) 38.5±0.5 (1.5±0.02) 300±30 (11.8±1.2) 5 (0.20) 5 (0.20) Motor ・ Low noise Common Elec. Spec. See pages G-11, G-12, G-13. ・ Interchangeable with currently installed box fans. D1238T12B7AZ-00 D1238T24B7AP-00 D1238T24B7AS-00 0 CNDC24D7VS ● Lead wire type 300±30 (11.8±1.2) (Pa) 160 1 0 2 3 Airflow (m3/mi n) Rotation 4 ■ Wiring connection diagram ) D1238T...B7 100 60 40 D1238T48B6AP-00 20 D1238T48B6AS-00 D1238T...B6 80 0 4-φ 4.5±0.3 (4-0.18 dia.) 0 1 2 3 4 5 Airflow (m3/mi n) ■ Mounting hole dimensions in mm (inches) [Recommendation] ■ Wiring connection diagram CNDC24Z7Q 4 13 a.) φ 8 di .2 5 ( When sensor is installed CNDC48B7P Power source (-): Black or blue and outlet sides CNDC48Z7 Ensure the guard is situated more than 10 mm from the fan to minimize noise increase when mounting a guard on the intake side. See page G-9. ・Filter: F120 filter Power source (-): Black Options (sold separately) ・Guard: F120UL guard ・Filter: F120 filter ・Spacer: Flange spacer CNDC 4-φ 4.5 (4-0.18 dia.) Identical for the intake Options (sold separately) ・Guard: F120UL guard 4-φ 4.5 (4-0.18 dia.) Outlet side Silent, low vibration and energy saving fans with a max. airflow of 2.8 m3/min can be customized (variable speed available only for 12 V specification). Contact Japan Servo for further information. Centrifugal Centrifugal CNDC48B7S 8 ) . 12 φ dia .04 5 ( When sensor is installed □116 (4.61 sq.) CNDC24Z7S CNDC48B7 Sensor output: Yellow ■ Mounting hole dimensions in mm (inches) [Recommendation] □104.8 (4.126 sq.) Sensor output: Yellow □116 (4.61 sq.) □104.8 (4.126 sq.) Airflow Airflow Rotation Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black DC axial fan with sensor Rated Vol. CNDC48Z7V 12 V CNDC12D7S CNDC12D7P CNDC24D7S CNDC24D7VS CNDC24D7P CNDC24D7Q 48 V Sensor Spec. G-15 Options CNDC12B7S CNDC12B7P CNDC24B7S CNDC24B7VS CNDC24B7P CNDC24B7Q CNDC24B7SQ CNDC48B7S CNDC48B7P G-72, 73, 74 CNDC12Z7S CNDC12Z7VS CNDC12Z7P CNDC24Z7S CNDC24Z7P CNDC24Z7Q CNDC48Z7S CNDC48Z7P ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). DC axial fan with sensor Rated Vol. 12 V 24 V 48 V Model Code D1238T12B6AS-00 D1238T12B7AS-00 D1238T12B6AP-00 D1238T12B7AP-00 D1238T24B7AS-00 D1238T24B7AP-00 D1238T48B6AS-00 D1238T48B7AS-00 D1238T48B6AP-00 D1238T48B7AP-00 ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. G-15 Options G-72, 73, 74 G-33 Options Options 24 V Model Code Axial CNDC24Z7P (5) AC fans Axial AC fans Power source (+): Red CNDC24Z7 (5) □104.8±0.3 (4.126 sq.±0.012) 19 (φ1 120 Power source (+): Red 8-φ 4.5±0.3 (8-0.18 dia.) 38.5±0.5 (1.5±0.02) □119±1 (4.72 sq.) 140 D1238T48B7AZ-00 20 CNDC24D7S ■ External dimensions in mm (inches) [By double chamber method] D1238T24B7AZ-00 D1238T48B7AS-00 60 User panel or guard Nut pocket ■ Standard airflow and static pressure characteristics (At rated voltage) D1238T48B7AP-00 CNDC...D7 Venturi M4 nut pockets (2 each) provided in 4 places for easy mounting. (The customer is to provide nuts) Front guard can be mounted easily. Fan model code D1238T12B6AZ-00 M4 nut M4 nut Brushless DC motor, Protection type: Overcurrent detection and automatic resetting by current limiting 40 CNDC24D7Q -20 ∼ +70 ●Fan mounting Venturi: ABS and PBT synthetic resins Materials Used Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing D1238T48B6AZ-00 CNDC...B7 80 3600 ・ Power saving ・ High airflow models, featuring an aerodynamic design inheriting the design concept of Silent Fans and incorporating a newly developed highefficiency motor. Flange with spacer CNDC...Z7 100 47.5 4000 Silent Static pressure CNDC24B7VS □120±1 (4.72 sq.) □104.8±0.3 (4.126 sq.±0.012) CNDC...H7 0.52 50 ■ General specification ■ Features ■ External dimensions in mm (inches) ● Lead wire type 130 0.64 ● The characteristics are the values at rated voltage (12 V or 48 V), and normal temperature and humidity. CNDC24B7V Use the reinforced product with spacer when the venturi is mounted with screws. (The spacer is indicated in the model code by the letter 'V'.) [By double chamber method] 141 160 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. Spacer With Spacer 155 4.0 ●Venturi shape Venturi: ABS and PBT synthetic resins Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing CNDC24B7V G-32 230 9.4 ■ General specification CNDC24B7SQ CNDC48Z7S 11.0 48 33.6-55.2 ● The life expectancy of CNCD-Z speed products at rated voltage and in continuous operation is 30,000 hours at 60℃. (40,000 hours for other products) CNDC24B7S CNDC48Z7P 1040 D1238T24B7AZ-00 2080 CNDC12H7 760 10.0 12 4.4 Operating Temp. Range ℃ Model Code 1500 D1238T12B7AZ-00 2000 CNDC24U7 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. CNDC24B7Q CNDC24U7 40 3200 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Speed min−1 490 450 8.4-13.8 Max. Airflow Max. Static Pressure Noise Pa inH2O dB 830 10.8 24 19.2-27.6 12 m3/min CFM 8.4-13.8 2100 CNDC12U7 9.1 With Spacer D1238T 11.7 24 18.0-27.6 930 ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. CNDC24B7P CNDC24H7 49 3550 Open Flange 8.4-13.8 11.2 12 Operating Temp. Range ℃ Centrifugal Centrifugal CNDC12Z7VS 0.18 51 3800 Model Code ■ Standard specification Axial CNDC12Z7 0.28 52 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting DC Axial Fan □ 120 × 38 mm DC fans Axial DC fans CNDC12U7 0.42 70 CNDC12D7V CNDC12H7 0.56 105 CNDC12D7P CNDC12D7S 0.64 Speed min−1 D1238T series Silent Silent Fan model code 124 160 □ 120 × 38 mm Static pressure CNDC series Brushless DC Fans & Blowers Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers D1238B series DC Axial Fan ■ Standard specification D1238B Max. Airflow Max. Static Pressure Noise m3/min CFM Pa inH2O dB 219 5.25 185 4.8 Max. airflow: 6.2 m3/min Max. static pressure: 300 Pa Mass: 430 g 1.21 250 169 4.4 □120×38 (□4.7"×1.5") 300 155 62 1.01 185 5500 59 0.74 160 Speed min−1 4900 56 0.64 4400 54 4000 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Operating Temp. Range ℃ Model Code 26.9 48 36-55.2 560 D1238B48BAAZ-00 19.8 12 8.4-13.8 1650 D1238B12B9AZ-00 19.7 24 16.8-27.6 820 19.2 48 36-55.2 14.4 12 D1338B series □ 127 × 38 mm DC Axial Fan ■ Standard specification D1338B m3/min CFM 1650 D1338B12B8AZ-00 820 D1338B24B8AZ-00 2600 D1238B24B9AZ-00 21.1 48 36-55.2 440 D1338B48B8AZ-00 400 D1238B48B9AZ-00 16.2 12 8.4-13.8 1350 D1338B12B7AZ-00 8.4-13.8 1200 D1238B12B8AZ-00 15.6 24 16.8-27.6 650 D1338B24B7AZ-00 13.9 24 16.8-27.6 580 D1238B24B8AZ-00 16.8 48 36-55.2 350 D1338B48B7AZ-00 12 8.4-13.8 1000 D1338B12B6AZ-00 12.0 24 16.8-27.6 500 D1338B24B6AZ-00 250 D1338B48B6AZ-00 15.4 48 36-55.2 320 D1238B48B8AZ-00 14.4 12 8.4-13.8 1200 D1238B12B7AZ-00 14.4 24 16.8-27.6 600 1600 D1238B24B7AZ-00 12.0 48 250 D1238B48B7AZ-00 36-55.2 5 -20 ∼ +70 D1238B12B8AS-00 Max. airflow: 5.8 m3/min Max. static pressure: 185 Pa Mass: 410 g Fan model code Materials Used Motor Brushless DC motor, Protection type: Overcurrent detection and automatic resetting by current limiting D1338B12B7AS-00 [By double chamber method] D1338B12B7AP-00 D1338B12B7AZ-00 D1238B24B7AS-00 (Pa) 300 ■ External dimensions in mm (inches) D1338B12B8AS-00 ● Lead wire type D1338B12B8AZ-00 □119±1 (4.72 sq.) □104.8±0.3 (4.126 sq.±0.012) D1238B24B7AZ-00 Centrifugal Static pressure D1238B24B8AS-00 D1238B24B8AZ-00 D1238B24B9AP-00 D1238B24B9AS-00 D1238B24B9AZ-00 4 (0.16) D1338B24B8AP-00 D1238B...B7 100 D1338B24B8AS-00 Rotation Airflow 0 1 ■ General specification Materials Used Venturi: Aluminum alloy die castings Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Motor Brushless DC motor, Protection type: Overcurrent detection and automatic resetting by current limiting Common Elec. Spec. See pages G-11, G-12, G-13. ■ Standard airflow and static pressure characteristics (At rated voltage) 5 Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black 6 ■ Mounting hole dimensions in mm (inches) [Recommendation] ■ Wiring connection diagram Power source (+): Red D1238B48B9AP-00 □116 (4.61 sq.) D1238B48B9AS-00 □104.8 (4.126 sq.) Sensor output: Yellow D1238B48B9AZ-00 D1238B48BAAP-00 Options (sold separately) ・Guard: F120UL guard ・Filter: F120 filter 200 40 0 D1338B48B6AZ-00 1 2 3 4 5 Airflow (m3/mi n) 6 D1338B48B7AP-00 D1338B48B7AS-00 D1338B48B7AZ-00 D1338B48B8AP-00 ■ Mounting hole dimensions in mm (inches) [Recommendation] ■ Wiring connection diagram D1338B48B8AS-00 Power source (+): Red □123 (4.84 sq.) D1338B48B8AZ-00 □113.3 (4.461 sq.) Sensor output: Yellow 9 ) . 13 φ dia 7 4 . (5 Power source (-): Black Outlet side D1238B12B9AS-00 D1238B12B9AP-00 D1238B24B9AS-00 D1238B24B9AP-00 D1238B48B9AS-00 D1238B48BAAS-00 D1238B48B9AP-00 D1238B48BAAP-00 G-15 Options G-72, 73, 74 Rated Vol. 12 V 24 V 48 V Model Code D1338B12B6AS-00 D1338B12B6AP-00 D1338B24B6AS-00 D1338B24B6AP-00 D1338B12B7AS-00 D1338B12B7AP-00 D1338B24B7AS-00 D1338B24B7AP-00 D1338B48B7AS-00 D1338B48B6AP-00 D1338B48B7AP-00 D1338B12B8AS-00 D1338B12B8AP-00 D1338B24B8AS-00 D1338B24B8AP-00 D1338B48B8AS-00 D1338B48B8AP-00 ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. G-15 Options G-72, 73, 74 G-35 Options Options Sensor Spec. Centrifugal Model Code ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). G-34 4-φ 4.5 (4-0.18 dia.) DC axial fan with sensor D1238B12B8AS-00 D1238B12B8AP-00 D1238B24B8AS-00 D1238B24B8AP-00 D1238B48B8AS-00 D1238B48B7AP-00 D1238B48B8AP-00 Axial Centrifugal 48 V Options (sold separately) ・Guard: F127UL guard AC fans Axial AC fans 24 V Airflow Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black When sensor is installed DC axial fan with sensor 12 V 8-φ 4.5 (8-0.18 dia.) Rotation 0 4-φ 4.5 (4-0.18 dia.) D1238B12B7AS-00 D1238B12B7AP-00 D1238B24B7AS-00 D1238B24B7AP-00 4 (0.16) 80 Power source (-): Black Rated Vol. 4 (0.16) D1338B...B6 D1238B48BAAZ-00 Customized fans with a higher airflow are also available. Please contact Japan Servo for more information. 38.5±0.5 (1.5±0.02) 300±30 (11.8±1.2) D1338B...B7 120 D1338B24B8AZ-00 □127±1 (5.0 sq.) □113.3±0.3 (4.461 sq.±0.012) D1338B...B8 160 .) 1 φ dia .04 (5 When sensor is installed ● Lead wire type [By double chamber method] (Pa) 28 D1238B48BAAS-00 ■ External dimensions in mm (inches) Silent Silent D1238B48B8AP-00 2 3 4 Airflow (m3/mi n) 36-55.2 ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. D1338B48B6AP-00 0 D1238B48B7AZ-00 3400 -20 ∼ +70 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. D1338B24B6AZ-00 D1338B24B7AZ-00 D1238B...B8 8-φ 4.5±0.3 (8-0.18 dia.) 51 3900 48 D1338B24B6AS-00 D1338B24B7AS-00 D1238B...B9 150 D1238B48B7AP-00 D1238B48B8AZ-00 4 (0.16) D1338B24B7AP-00 50 D1238B48B8AS-00 D1338B24B6AP-00 38.5±0.3 (1.5±0.01) D1238B...BA 200 0.52 54 4500 Centrifugal 250 D1238B24B8AP-00 300±30 (11.8±1.2) 0.60 58 Axial D1238B24B7AP-00 0.74 DC fans Axial DC fans D1238B12B9AZ-00 130 D1338B12B6AZ-00 D1338B12B8AP-00 ■ Standard airflow and static pressure characteristics (At rated voltage) D1238B12B9AS-00 150 D1338B12B6AP-00 Common Elec. Spec. See pages G-11, G-12, G-13. D1238B12B9AP-00 162 185 □127×38 (□5.0"×1.5") D1338B12B6AS-00 D1238B12B8AZ-00 177 4.6 Venturi: Aluminum alloy die castings Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing D1238B12B8AP-00 205 Operating Temp. Range ℃ Silent Silent D1238B12B7AZ-00 Model Code 8.4-13.8 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. D1238B12B7AS-00 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 19.7 24 16.8-27.6 ■ General specification D1238B12B7AP-00 Speed min−1 19.8 12 5.8 ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. Fan model code Max. Airflow Max. Static Pressure Noise Pa inH2O dB Static pressure 6.2 □ 120 × 38 mm Brushless DC Fans & Blowers Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers D1338S series □ 127 × 38 mm DC Axial Fan ■ Standard specification D1338S Max. Airflow Max. Static Pressure Noise m3/min CFM Pa inH2O dB 5.1 180 185 0.74 53 Speed min−1 4300 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 16.8 48 36-55.2 350 Operating Temp. Range ℃ Model Code 950 D1338S48B7AZ-00 Brushless DC Fans & Blowers D1725M series φ172 × 147 × 25 mm DC Axial Fan ■ Standard specification DC TUBEAXIAL FAN m3/min CFM -20 ∼ +70 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (48 V), and normal temperature and humidity. Max. Airflow Max. Static Pressure Noise Pa inH2O dB Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Speed min−1 6.4 226 135 0.54 57 3400 5.2 184 92 0.37 51 2800 Model Code 24 24 20.4-27.4 1000 D1725M24B7AZ-00 25 48 40.8-55.2 520 D1725M48B7AZ-00 15.6 12 10.2-13.8 1300 D1725M12B5AZ-00 Operating Temp. Range ℃ -10∼+60 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. ■ General specification Motor Brushless DC motor, Protection type: Overcurrent detection and automatic resetting by current limiting D1725M12B5AZ-00 ■ External dimensions in mm (inches) D1725M24B7AZ-00 ● Lead wire type 300±30 (11.8±1.2) 160 120 80 38.5±0.5 (1.5±0.02) □127±1 (5.0 sq.) □113.3±0.3 (4.461 sq.±0.012) D1725M24B7 D1725M48B7 40 5 (0.20) 0 1 φ ± 27 4 Airflow (m3/mi n) 6 8 1 80 ■ External dimensions in mm (inches) 40 ● Lead wire type ■ Mounting hole dimensions in mm (inches) [Recommendation] 8-φ 4.5±0.3 6 4-φ 4.3±0.3 (4-0.17 dia.) Rotation +50 4-φ 11.5±0.5 (Dia. of support) Airflow Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black ■ Wiring connection diagram Sensor output: Yellow When sensor is installed ■ Mounting hole dimensions in mm (inches) [Recommendation] □123 (4.84 sq.) □113.3 (4.461 sq.) 300 0 (12 +20 ) φ φ116622 (6 (6.3 .388ddia ia.).) R5 110゚ Options (sold separately) ・Guard: F127UL guard 7.5 (0.3) 25.4±0.5 (1±0.02) 147 (5.79) Rotation 9 13 a.) φ 7 di 4 . (5 7.5 (0.3) 4-φ 4.5 (4-0.18 dia.) Silent Silent Power source (+): Red 147 (5.79) (8-0.18 dia.) Centrifugal Centrifugal 2 3 4 5 n) Airflow (m3/mi (6 φ 1 .6 68 1 di a. ) 1 φ 162±0.5 (6.38±0.02 dia.) 0 φ 172 (6.77 dia.) 0 Axial 2 0 D1338S...B7 120 DC fans Axial DC fans Static pressure (Pa) 200 D1725M12B5 160 D1725M48B7AZ-00 [By double chamber method] D1338S48B7AZ-00 200 Silent Silent Fan model code ■ Standard airflow and static pressure characteristics (At rated voltage) 240 Max. airflow: 6.4 m /min Max. static pressure: 135 Pa Mass: 500 g Fan model code D1338S48B7AS-00 (Pa) 3 Common Elec. Spec. See pages G-11, G-12, G-13. D1338S48B7AP-00 [By double chamber method] φ172×147×25 (φ6.8"×6.0"×1.0") Static pressure Materials Used □127×38 (□5.0"×1.5") Max. airflow: 5.1 m3/min Max. static pressure: 185 Pa Mass: 495 g ■ Standard airflow and static pressure characteristics (At rated voltage) Venturi: Aluminum alloy die castings Propelle: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers 110° Identical for the intake and outlet sides Airflow Axial Axial AC fans AC fans Lead wire spec. AWG24 UL1007 Color (+) Red ( - ) Black (D1725M12B: Blue) Power source (-): Black 4-φ 4.5(4-0.18 dia.) Outlet side ■ Wiring connection diagram Power source (+): Red Rated Vol. Model Code 48 V D1338S48B7AS-00 D1338S48B7AP-00 Centrifugal Centrifugal DC axial fan with sensor Power source (-): Black or blue ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. Options Options G-36 Sensor Spec. G-15 Options G-72, 73, 74 G-37 ■ Standard specification DC Axial Fan ■ Standard specification DC PARKY III m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB m3/min CFM Speed min−1 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 10.2 360 380 1.53 64 4800 47.5 48 40.8-55.2 990 9 318 290 1.17 61 4200 33.6 48 40.8-55.2 700 12 8.4-13.8 8 282 235 0.95 57 3800 25.2 24 12-27.6 30 6.8 φ172×150×51 (φ6.8"×6.0"×2.0") 5.8 Max. airflow: 10.2 m3/min Max. static pressure: 380 Pa Mass: 0.8 kg MADC12H7P MADC12H7S MADC24B4Q 1500 MADC12Z4 24 12-27.6 790 MADC24Z4 19 13 2000 5 48 28.8-55.2 400 MADC48Z4 12 8.4-13.8 1080 MADC12B4 24 12-27.6 540 MADC24B4 48 28.8-55.2 270 MADC48B4 12 8.4-13.8 420 MADC12D4 24 12-27.6 210 MADC24D4 Max. airflow: 10.2 m3/min Max. static pressure: 380 Pa Mass: 0.8 kg Fan model code PADC12B4 700 12 8.4-13.8 8 282 235 0.95 55 3800 25.2 24 12-27.6 176 240 PADC24B4Q 5.8 205 4.2 140 148 ■ External dimensions in mm (inches) PADC24H7Q ● Lead wire type PADC24Z4 8-φ 4.5±0.3 (8-0.18 dia.) (Pa) 360 280 MADC24Z4SQ MADC48B4 MADC48B4P (6.3 .012 MADC...U7 240 φ1 62 78 d ±0.3 ia. ± 0 51±0.5 (2±0.02) 7.5 (0.30) 7.5 (0.30) 300±30 (11.8±1.2) ) φ 172 (6.77 dia.) 320 MADC24Z4Q Static pressure MADC24Z4P MADC...S7 DC Maxi III MADC...H7 200 MADC...Z4 160 MADC...B4 120 111° +0.2° 80 MADC48S7 Rotation 40 MADC48S7S 0 2 0 MADC48S7Q 4 6 8 10 Airflow (m3/mi n) ■ Wiring connection diagram MADC48Z4P Power source (+): Red φ 166 (6 (In .5 ta 4 d ke ia sid .) e: φ 116 600 )) 162 (6.378) Power source (-): Black or blue 790 PADC24Z4 48 28.8-55.2 400 PADC48Z4 PADC24Z4P 12 8.4-13.8 1080 PADC12B4 24 12-27.6 540 PADC24B4 48 28.8-55.2 270 PADC48B4 12 8.4-13.8 420 39 PADC12D4 24 12-27.6 210 PADC24D4 13 2000 5 Brushless DC motor, Protection type: Overcurrent detection and automatic resetting by current limiting ■ Standard airflow and static pressure characteristics (At rated voltage) φ φ11662 2 (6.37 8) R5 ● Lead wire type PADC24Z4S 320 PADC48B4 280 12-φ 4.5±0.3 (12-0.18 dia.) 300±30 (11.8±1.2) φ (6.37 162±0.3 8 dia .±0.01 PADC...S7 2) DC PARKY PADC...U7 240 PADC...H7 200 PADC...Z4 160 PADC...B4 PADC48U7 120 111゚±2゚ PADC48Z4 80 Rotation 40 0 2 4 6 Airflow (m3/mi n) 8 10 Power source (+): Red 162 (6.38) Sensor output: Yellow When sensor is installed 3-φ 4.5 (3-0.18 dia.) Power source (-): Black or blue MADC24D4Q 2 (6.3 78) R5 The PADC series is being revised to the D1751S series in the near future. 3-φ 4.5 (3-0.18 dia.) 4-R5 4-φ 4.5 (4-0.18 dia.) The new series of fans feature a max. airflow of 14 m3/min and a noise reduction of 3 dB. Please contact Japan Servo for more information. (4 point mounting) 111° (3 point mounting) Options (sold separately) ・Guard: GUARD172 MADC24B4P MADC24B4Q MADC24B4SQ MADC48B4P MADC24Z4P MADC24Z4Q MADC24Z4SQ MADC48Z4P MADC48Z4SQ DC axial fan with sensor MADC12H7S MADC12H7P Rated Vol. MADC48S7S MADC48S7Q ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). G-15 Options G-72, 73, 74 Model Code 12 V 24 V PADC24B4S PADC24B4P PADC24B4Q PADC12Z4P PADC24Z4S PADC24Z4P PADC24Z4Q PADC24H7Q ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. G-15 Options G-72, 73, 74 G-39 Options Options 48 V Sensor Spec. φ 16 Centrifugal Centrifugal (3 point mounting) ia. 4d 6.5 6 ( 60) 1 φ (φ 16 Model Code MADC12Z4P 12 V G-38 7.5 (0.30) ■ Mounting hole dimensions in mm (inches) [Recommendation] ■ Wiring connection diagram DC axial fan with sensor 24 V 51±0.5 (2±0.02) Airflow Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (PADC□D4: Blue) PADC...D4 0 7.5 (0.30) ) 111° 2-φ 4.5 (2-0.18 dia.) Rated Vol. -20 ∼ +60 ■ External dimensions in mm (inches) [By double chamber method] PADC24Z4Q PADC48S7 0.28 2800 Motor (Pa) 360 PADC48H4 46 Venturi: Aluminum alloy die castings Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Options (sold separately) ・Guard: GUARD172 2-R5 (2 point mounting) 12-27.6 Axial When sensor is installed PADC12Z4 24 19 146 (5.75) Sensor output: Yellow ) ia.). ddia 5544 66.. 600)) ( ( 6 66 1166 (φ11 φφ (φ 1500 Materials Used ■ Mounting hole dimensions in mm (inches) [Recommendation] 146 (5.75) 1100 PADC48H4 8.4-13.8 AC fans Axial AC fans MADC48Z4SQ Airflow Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black (MADC□D4: Blue) MADC...D4 600 12 Silent Silent MADC48H4 28.8 48 40.8-55.2 Standard Carton 12 to a carton of (450 x 380 x 220) mm, mass 10.5 kg PADC24H7 150 (5.91) 3200 2500 5800 PADC12H7 1050 2760 PADC24H7 Common Elec. Spec. See pages G-11, G-12, G-13. PADC24D4 [By double chamber method] 50 0.56 69 PADC24B4S Standard Carton 12 to a carton of (450 x 380 x 220) mm, mass 10 kg ■ Standard airflow and static pressure characteristics (At rated voltage) 0.71 2600 PADC48S7 2600 PADC48U7 ■ General specification PADC24B4 Common Elec. Spec. See pages G-11, G-12, G-13. MADC24Z4 MADC48Z4 990 33.6 48 40,8-55.2 PADC24B4P MADC24H7 MADC48U7 47.5 48 40.8-55.2 4200 Centrifugal Centrifugal MADC24D4Q 4800 59 PADC12Z4P MADC24B4SQ MADC24D4 62 1.17 ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. PADC12Z4 Brushless DC motor, Protection type: Overcurrent detection and automatic resetting by current limiting 1.53 290 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. PADC12D4 ■ General specification Motor 380 318 φ172×51 (φ6.8"×2.0") PADC12H7 Materials Used 360 9 6.8 -20 ∼ +60 ● The characteristics are the values at rated voltage (12 V, 24 V or 48 V), and normal temperature and humidity. Venturi: Aluminum alloy die castings Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing 10.2 Operating Temp. Range ℃ Model Code Axial MADC24B4P 42 1100 MADC48H4 8.4-13.8 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. MADC12Z4P MADC24B4 0.28 69 2800 600 12 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 30 2500 5800 MADC12H7 1050 2700 MADC24H7 28.8 48 40.8-55.2 Speed min−1 DC fans Axial DC fans MADC12Z4 148 49.5 3200 2600 MADC48S7 2600 MADC48U7 Static pressure MADC12H7 0.56 140 54 Max. Airflow Max. Static Pressure Noise Pa inH2O dB Silent Silent MADC12D4 0.71 176 205 4.2 Fan model code MADC12B4 240 Operating Temp. Range ℃ Model Code φ 172 (6.77 dia.) DC MAXI III Fans & Blowers Fans & Blowers PADC series φ172 × 51 mm φ (In 166 tak (6 e s .5 ide 4 d : φ ia.) 16 0) DC Axial Fan MADC series φ172 × 150 × 51 mm Brushless DC Fans & Blowers 162 (6.378) Brushless DC Fans & Blowers Brushless DC Fans & Blowers G0938 Series □ 92 × 38 mm ■ Standard specification G0938B m3/min CFM 3.9 3.6 □92×38 (□3.62"×1.5") 138 127 Max. static pressure Pa inH2O Noise dB Speed min−1 490 1.97 63 7500 440 1.77 61 7000 Voltage spec. V Current mA Rating Operating Range Rating Starting Model code 12 8.4-13.2 2600 4900 G0938B12BAZP-00 24 16.8-26.4 1300 2700 G0938B24BAZP-00 48 36-52.8 610 1360 G0938B48BAZP-00 12 8.4-13.8 2000 4600 G0938B12B9ZP-00 24 16.8-27.6 1000 2600 G0938B24B9ZP-00 48 36-55.2 520 1100 G0938B48B9ZP-00 ■ Standard airflow and static pressure characteristics (At rated voltage) Operating temp. range ℃ DC Axial Fan Fixed Blade Type G1238B G1238 Series □ 120 × 38 mm ■ Standard specification Max. airflow m3/min CFM 7.4 261 Max. static pressure Pa inH2O Noise dB Speed min−1 520 2.09 67 6300 -20 ∼ +60 6.3 ■ External dimensions in mm (inches) ● Lead wire type □120×38 (□4.75"×1.5") 223 415 1.67 64 5300 ■ Standard airflow and static pressure characteristics (At rated voltage) Voltage spec. V Current mA Rating Operating Range Rating Starting Model code 12 9.6-13.8 4450 6100 G1238B12BBZP-00 24 16.8-27.6 2200 3100 G1238B24BBZP-00 48 36-55.2 1100 1600 G1238B48BBZP-00 24 16.8-27.6 1300 2000 G1238B24BAZP-00 48 36-55.2 660 970 G1238B48BAZP-00 Operating temp. range ℃ -20 ∼ +60 -20 ∼ +70 ■ External dimensions in mm (inches) Fans & Blowers Fans & Blowers DC Axial Fan Fixed Blade Type Max. airflow Brushless DC Fans & Blowers ● Lead wire type Max. airflow:7.4 m3/min Max. static pressure:520 Pa Mass:480 g Max. airflow:3.9 m3/min Max. static pressure:490 Pa Mass:320 g Fan model code G1238B12BBZP-00 G0938B24BAZP-00 G1238B24BBZP-00 G0938B48BAZP-00 G1238B48BBZP-00 G0938B12B9ZP-00 G1238B24BAZP-00 G0938B24B9ZP-00 G1238B48BAZP-00 Silent Silent Fan model code G0938B12BAZP-00 G0938B48B9ZP-00 For cooling and/or ventilating in electronic cabinets which have high registance to air flow (system impedance). The G0938 is designed using a digital analysis system to maximize cooling efficiency and minimize noise during operation. Uniquely formed fixed blades designed by digital engineering: ・Controls spread of air stream. ・When two G0938 fans are stacked, the static pressure is almost doubled. It is suitable for use in highly reliable/redundant designs; the trend of cooling systems. For cooling and/or ventilating in electronic cabinets which have high registance to air flow (system impedance). The G1238 is designed using a digital analysis system to maximize cooling efficiency and minimize noise during operation. Uniquely formed fixed blades designed by digital engineering: ・Controls spread of air stream. ・When two G1238 fans are stacked, the static pressure is almost doubled. It is suitable for use in highly reliable/redundant designs; the trend of cooling systems. ● To ensure correct installation and smooth operation please obtain a drawing for approval or reference drawing from Japan Servo Co. ● To ensure correct installation and smooth operation please obtain a drawing for approval or reference drawing from Japan Servo Co. Centrifugal Centrifugal ■ PWM speed control specification Axial DC fans Axial DC fans ■ PWM speed control specification Silent Silent Axial AC fans Axial AC fans Centrifugal Centrifugal Sensor Spec. G-15 Options G-72, 73, 74 Sensor Spec. G-15 Options G-72, 73, 74 G-41 Option Option G-40 G1751M series φ172 × 150 × 51 mm For a high static pressure region ■ Standard specification m3/min CFM G1751M Pa Speed Input Voltage Spec. V Current mA min−1 W Rating Operating Range Rating Starting Noise dB inH2O Operating Temp. Range ℃ Model Code 11.2 395 840 3.38 76(8.2m3/min) 6800 120 36-50.4 2500 5000 G1751M48B9AZ-00 10.0 353 710 2.85 71(7.5m3/min) 6200 86 1800 4400 G1751M48B8AZ-00 3 9.2 325 580 2.33 8.3 293 490 1.97 66.5(6.1m3/min) 5100 50 7.3 258 360 1.45 63(5.3m3/min) 36 69(6.7m /min) 5600 62.4 48 4500 36-60 1300 4400 G1751M48B7AZ-00 1040 2700 G1751M48B6AZ-00 750 DC Axial Fan ■ Standard specification DC SATURN -20 ∼ +50 -20 ∼ +60 φ200 × 70 mm Max. Airflow Max. Static Pressure Noise Pa inH2O dB m3/min CFM Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Speed min−1 Hi Lo 10 8.7 353 307 214 189 0.86 0.76 59 55 3200 2800 41 29 24 20.4-27.6 Hi Lo 9 7.5 318 265 201 153 0.81 0.62 55 51.5 2900 2500 31 19 24 20.4-27.6 2550 G1751M48B5AZ-00 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. Hi Lo ● The characteristics are the values at rated voltage (48 V), and normal temperature and humidity. 7.7 6.2 158 110 272 219 53 46.5 0.64 0.44 Max. airflow: 10 m3/min (Dual speeds) Max. static pressure: 214 Pa Mass: 1.7 kg Fan model code G1751M48B5AP-00 Common Elec. Spec. See pages G-11, G-12, G-13. SADC24B5P G1751M48B5AZ-00 Standard Carton 12 to a carton of (450 x 380 x 220) mm, mass 11 kg SADC24X5P G1751M48B6AP-00 ■ Standard airflow and static pressure characteristics (At rated voltage) ■ External dimensions in mm (inches) SADC24Z5P ● Lead wire type SADC24Z5SQ [By double chamber method] 300±30 (1.18±1.2) 70 G1751M...B9 G1751M...B8 60 φ 162±0.3 (6.378 di a.± 0.012) G1751M...B7 (Pa) 900 G1751M...B6 600 Lead wire spec. AWG24 UL3266 Color (+) Red ( - ) Black G1751M...B8 G1751M...B7 500 G1751M...B6 ■ Mounting hole dimensions in mm (inches) [Recommendation] 400 300 146 (5.75) 2 0 4 6 8 Airflow (m3/mi n) 10 12 ● Ranges shown by solid lines are the recommended operation ranges. The MADC series is recommended for use in ranges shown by the dotted lines. 162 (6.378) G1751M...B5 Materials Used 2-φ 4.5 (2-0.18 dia.) ■ Standard airflow and static pressure characteristics (At rated voltage) Speed Mode Speed control signal High Speed Open (10 μA or less) Low Speed VL = 0.8 V or less Io = 6 mA MAX. (VL = 0 V) [By double chamber method] (Pa) 240 (Pa) 240 SADC...Z5 120 80 Lo 120 80 40 0 0 2 4 6 Airflow (m3/mi n) 8 10 Lo 2 0 160 Hi 120 80 40 4 6 Airflow (m3/mi n) ■ External dimensions in mm (inches) 8 10 0 Lo 0 2 4 6 Airflow (m3/mi n) 8 10 ■ Mounting hole dimensions in mm (inches) [Recommendation] ● Lead wire type 0 Grounding tap (M4 effective depth 6) 70 - 1 0 7.5±0.3 (0.30) Rotation 3-φ 4.5 (3-0.18 dia.) SADC...B5 200 Hi 160 40 0 SADC...X5 200 Hi 160 (Pa) 240 (2.76 ) -0.04 188.4 (7.4) 7.5±0.3 (0.30) 300 ±30 (11.8±1.2) 111° (3 point mounting) UL1007 AWG22 Options (sold separately) ・Guard: GUARD172 New! φ 4 (φ 19 8) 18 4-R5 The G1751M series has been designed for use in high static pressure regions, with a quieter and lower input compared with the SADC and MADC series. The MADC series is recommended for use in a high airflow region. (See Fig. 4 on page G-6.) 8-φ 4.5±0.3 (8-0.18 dia.) 4-φ 4.5 (4-0.18 dia.) Airflow Centrifugal As of Jan. 2007, higher performance models will soon be released. GND Black 188.4 ±0.33 (7.417±0.013) Options (sold separately) ・Guard: F200UL guard Variable speed products (G-58 and G-59) have also been released. DC axial fan with sensor DC axial fan with sensor Rated Vol. G1751M48B5AP-00 G1751M48B6AP-00 G1751M48B7AP-00 ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. G-42 Sensor Spec. G-15 Options G-72, 73, 74 Rated Vol. 24 V 48 V Model Code SADC24B5P SADC48B5P SADC24X5P SADC24Z5SQ ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 Sensor Spec. G-15 Options G-72, 73, 74 G-43 Option Option 48 V Model Code Axial Centrifugal Power source (-): Black Sensor output (Open collector) Yellow AC fans Axial AC fans (2 point mounting) Speed change Fan Brushless DC motor Dual-speed change and pulse output type. A rotation sensor installed. Protection type: Overcurrent detection and automatic resetting by current limiting Common Elec. Spec. See pages G-11, G-12, G-13. φ φ11662 2 (6.37 8) R5 Power source (+): Red When sensor is installed 146 (5.75) +24 VDC Brown Motor 2-R5 ■ Wiring connection diagram Sensor output: Yellow ) ia.). ddia 5544 66.. 600)) ( ( 6 66 1166 (φ11 φφ (φ Red Venturi: Aluminum alloy die castings Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Silent Silent 200 100 Airflow Rotation G1751M...B9 ■ Wiring connection diagram ■ General specification Centrifugal Centrifugal Static pressure ● The products feature a speed feedback control system and their speeds remain constant, even if the operating voltage is higher than the rated voltage. 200 111゚±2゚ 700 0 ● The characteristics are the values at rated voltage (24 V or 48 V), and normal temperature and humidity. G1751M...B5 800 SADC48B5P 0 High static pressure fans suitable for cooling densely assembled equipment. 0.5 0.33 Standard Carton 5 to a carton of (465 x 300 x 290) mm, mass 9 kg φ 172 (6.77 dia.) G1751M48B9AZ-00 Noise 80 0.65 Axial G1751M48B8AZ-00 SADC48B5P 7.5 (0.3) 7.5 (0.3) 8-φ 4.5±0.3 (8-0.18 dia.) SADC24B5P DC fans Axial DC fans G1751M48B7AZ-00 51±0.5 (2±0.02) 150 (5.91) [dB (A)] 90 -20 ∼ +70 1.0 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. 0 G1751M48B7AP-00 φ 166 (6 (In .5 ta 4 d ke ia sid .) e: φ 116 600 )) G1751M48B6AZ-00 SADC24X5P 0.8 Silent Silent Brushless DC motor, Protection type: Overcurrent detection and automatic resetting by current limiting Motor Fan model code Venturi: Aluminum alloy die castings Propeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing φ200 - (7.87dia. ) 1 -0.04 Materials Used Static pressure Max. airflow: 11.2 m3/min Max. static pressure: 840 Pa Mass: 0.82 kg φ200×70 (φ7.8"×2.8") Static pressure φ172×150×51 (φ6.8"×6.0"×2.0") 1.3 48 40.8-55.2 ■ General specification Operating Temp. Range ℃ Model Code SADC24Z5P 1.2 24 20.4-27.6 24 16 2600 2100 1.7 Static pressure Max. Airflow Max. Static Pressure SADC series Fans & Blowers Fans & Blowers DC Axial Fan Fixed Blade Type Brushless DC Fans & Blowers 188.4 (7.4) Brushless DC Fans & Blowers Speed Voltage Spec. V Current mA min−1 Rating Operating Range Rating Starting 12 0.22 7.8 220 0.88 42.5 4.5-13.8 230 E0525H12B7AZ-00 530 E0525K12B7AZ-00 6700 24 9.6-27.6 110 Operating Temp. Range ℃ Model Code E0525K24B7AZ-00 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. □51×15 (□2.0"×0.6") Materials Used Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset Max. airflow: 0.125 m3/min Max. static pressure: 210 Pa Mass: 30 g Fan model code Common Elec. Spec. See pages G-11, G-12, G-13. E0515H12B5AZ-00 ■ Standard airflow and static pressure characteristics (At rated voltage) ■ External dimensions in mm (inches) E0515H12B7APA01 ● Lead wire type (E0525H) E0515H12B7ASA01 [By double chamber method] E0525H12B7AS-00 150 100 50 H Outlet 0.05 0.1 0.15 0.2 0.25 Airflow (m3/mi n) 0.3 19.7±0.3 (0.776±0.012) 23.7 (0.93) 9.5 (0.37) Intake 6100 0.11 3.9 165 0.66 40 5500 0.1 3.5 135 0.54 37 5000 0.09 3.2 110 0.44 34 4500 2.3 12 6-13.8 190 320 E0515H12B8AZA01 2.4 24 12-27.6 100 160 E0515H24B8AZA01 1.7 12 6-13.8 140 225 E0515H12B7AZA01 1.9 24 12-27.6 80 130 E0515H24B7AZA01 1.4 12 9.6-13.8 120 190 E0515H12B5AZ-00 1.4 24 16.8-27.6 60 110 E0515H24B5AZ-00 1.1 12 9.6-13.8 90 150 E0515H12B3AZ-00 E0525K12B7AZ-00 -20 ∼ +80 -20 ∼ +60 ● Life expectancy of the E0515H series in continuous operation at rated voltage is 15,000 hours at an operating temperature of 60 ℃ ■ General specification Materials Used Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset Common Elec. Spec. See pages G-11, G-12, G-13. ■ Standard airflow and static pressure characteristics (At rated voltage) E0515H24B5AZ-00 (Pa) E0515H24B7APA01 280 E0515H24B7ASA01 240 E0515H24B8ASA01 E0515H24B8AZA01 E0515H...B8 E0515H...B5 E0515H...B3 160 120 80 40 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 Airflow (m3/mi n) ● Lead wire type (E0525K) ■ Wiring connection diagram 19.1 (0.752±0.012) Intake Outlet 20±0.3 (0.787±0.012) 24.7 (0.93) 51 (2.01) Lead wire spec. AWG26 or UL3265 AWG26 Color (+) Red ( - ) Black (CNDC□D4: Blue) 23.7 (0.93) When sensor is installed Power source (-): Black 19.7±0.3 (0.776±0.012) Axial 26.2 (1.03) 21.8 (0.86) Outlet K AC fans Axial AC fans Intake 15 (0.59) Sensor output: Yellow 21.6±0.3 (0.850±0.012) 48 (1.89) Power source (-): Black 2-φ 4.5 (Through hole) (2-0.18 dia. HOLES) Power source (+): Red Lead wire length 300±30 (11.8±1.2) 9.5 (0.37) 17.2±0.3 (0.677±0.012) 9.5 (0.37) 2-φ 3.5 (Through hole) (2-0.14 dia. HOLES) φ 36 (Intake inside dia.) (1.42 dia. Intake) Silent Silent 25 (0.98) 18±0.3 (0.709±0.012) E0515H......B7 200 0 φ 28 (Intake inside dia.) (1.10 dia.Intake) ● Lead wire type Lead wire length 300±30 (11.8±1.2) Power source (+): Red Sensor output: Yellow ■ External dimensions in mm (inches) [By double chamber method] Lead wire spec. UL3265 AWG26 Color (+) Red ( - ) Black ■ Wiring connection diagram When sensor is installed -20 ∼ +60 ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. E0515H12B8AZA01 E0515H24B7AZA01 48 (1.89) E0525K12B7AS-00 E0525K24B7AZ-00 E0515H12B8ASA01 E0515H24B8APA01 0 E0525K12B7AP-00 17.2±0.3 (0.677±0.012) 200 E0515H12B8APA01 25 (0.98) 9.5 (0.37) E0525H/K...B7 0 E0525H24B7AZ-00 42 Centrifugal Centrifugal E0525H12B7AZ-00 2-φ 3.5 (Through hole) (2-0.14 dia. HOLES) 19.1±0.3 (0.752±0.012) Lead wire length 300±30 (11.8±1.2) 26.2 (1.03) Static pressure E0525H12B7AP-00 0.84 Axial Fan model code E0515H12B7AZA01 φ 28 (Intake inside dia.) (1.10 dia. Intake) (Pa) 300 250 210 Operating Temp. Range ℃ Model Code DC fans Axial DC fans ・ Both clockwise and counterclockwise discharge (mirror-image) versions are available. 4.4 E0515H12B3AZ-00 21.8 (0.86) ・ The smaller 48 mm square blower gives as much airflow output as a larger 70 mm square blower while maintaining the same low noise level. 0.125 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Silent Silent ■ Features Speed min−1 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. 21.6±0.3 (0.850±0.012) Max. airflow: 0.22 m3/min Max. static pressure: 220 Pa Mass: 50 g ■ General specification 48 (1.89) □48×25 (□1.9"×1.0") Max. Airflow Max. Static Pressure Noise Pa inH2O dB -20 ∼ +70 E0525H24B7AZ-00 280 E0515H m3/min CFM 20±0.3 (0.787±0.012) Max. Airflow Max. Static Pressure Noise Pa inH2O dB ■ Standard specification 28.2 (1.11) m3/min CFM DC Centrifugal Blowers 20 (0.79) E0525H/K 51 × 53 × 15 mm 23±0.3 (0.906±0.012) ■ Standard specification E0515H series 52.6 (2.07) Super Silent Blowers □ 48 × 25 mm Static pressure E0525H/K series Brushless DC Fans & Blowers Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers 48 (1.89) Rated Vol. 12 V Model Code E0525H12B7AS-00 E0525K12B7AS-00 E0525H12B7AP-00 E0525K12B7AP-00 G-44 Sensor Spec. G-15 DC centrifugal blower with sensor Rated Vol. 12 V 24 V Model Code E0515H12B7ASA01 E0515H12B7APA01 E0515H24B7ASA01 E0515H24B7APA01 E0515H12B8ASA01 E0515H12B8APA01 E0515H24B8ASA01 E0515H24B8APA01 ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. G-15 G-45 Option Option ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, TUV: R50004410 Centrifugal Centrifugal Super silent blower with sensor E0720H series Super Silent Blowers ■ Standard specification E0720H m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB 0.29 10.2 0.27 9.5 0.25 8.8 300 250 210 1.21 44 1.01 42 0.84 40 70 × 76 × 20 mm Speed Voltage Spec. V Current mA min−1 Rating Operating Range Rating Starting 4750 4400 4050 12 5-13.8 300 24 10-27.6 140 12 5-13.8 240 24 10-27.6 120 12 5.5-13.8 200 24 10-27.6 100 Operating Temp. Range ℃ Model Code Brushless DC Fans & Blowers E0720L series 72 × 75 × 20 mm Super Silent Blowers ■ Standard specification E0720L m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB Speed Voltage Spec. V Current mA min−1 Rating Operating Range Rating Starting 580 E0720H12B8AZ-00 270 E0720H24B8AZ-00 0.31 10.9 265 1.07 41 4200 0.30 10.6 245 0.98 40.5 4050 480 E0720H12B7AZ-00 240 E0720H24B7AZ-00 0.27 9.5 190 0.76 38 3700 -20 ∼ +70 12 Operating Temp. Range ℃ Model Code 4.5-12.8 300 4.5-13.8 260 620 E0720L12B8AZ-00 520 E0720L12B7AZ-00 4.5-13.8 190 390 E0720L12B5AZ-00 -20 ∼ +70 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. 390 E0720H12B5AZ-00 200 E0720H24B5AZ-00 ● The characteristics are the values at rated voltage (12 V), and normal temperature and humidity. ● The life expectancy of E0720L-8 speed products at rated voltage and in continuous operation is 18,000 hours at 60 ℃. (25,000 hours for other products) ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. □72×20 (□2.8"×0.8") ■ General specification Max. airflow: 0.31 m3/min Max. static pressure: 265 Pa Mass: 50 g Fan model code Materials Used Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset E0720H12B7AP-00 Common Elec. Spec. See pages G-11, G-12, G-13. E0720H12B7AS-00 Standard Carton 150 to a carton of (450 x 380 x 295) mm, mass 8 kg ■ External dimensions in mm (inches) ● Lead wire type [By double chamber method] E0720H24B8AZ-00 E0720H...B7 200 150 100 50 0 E0720H...B5 0.1 0.2 Airflow (m3/mi n) 0.3 2-φ 4.5 (Through hole) (2-0.18 dia. HOLES) 31±0.3 (1.22±0.012) 32.1 (1.26) E0720L12B8AS-00 E0720L12B8AZ-00 E0720L...B5 150 100 0 0.1 0.2 Airflow (m3/mi n) 0.3 ■ Wiring connection diagram Sensor output: Yellow When sensor is installed When sensor is installed Rated Vol. Sensor Spec. G-15 Model Code E0720L12B8AS-00 E0720L12B8AP-00 ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 G-47 Option Option ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 12 V Centrifugal Centrifugal Super silent blower with sensor Rated Vol. 24 V Lead wire spec. AWG26 UL3265 Color (+) Red ( - ) Black Power source (-): Black Super silent blower with sensor 12 V 31±0.3 35.7 (1.22±0.012) (1.41) 72.6 (2.86) Axial Sensor output: Yellow 2-φ 4.5 (Through hole) (2-0.18 dia. HOLES) AC fans Axial AC fans Power source (+): Red E0720H12B5AS-00 E0720H12B7AS-00 E0720H12B8AS-00 E0720H12B8AP-00 E0720H12B5AP-00 E0720H12B7AP-00 E0720H24B8AS-00 E0720H24B8AP-00 Outlet Intake 50 Power source (+): Red Model Code 26±0.3 20 (1.024±0.012) Lead wire length300±30 (0.79) (11.8±1.2) E0720L...B7 200 Power source (-): Black G-46 E0720L...B8 250 70.2 (2.76) Lead wire spec. AWG26 UL3265 Color (+) Red ( - ) Black (CNDC□D4: Blue) φ 44 (Intake inside dia.) (1.69 dia.Intake) Silent Silent ■ Wiring connection diagram Outlet E0720L12B7AZ-00 E0720L12B8AP-00 Intake (Pa) 300 E0720L12B5AZ-00 26±0.3 (1.024±0.012) E0720H24B8AS-00 φ 44 (Intake inside dia.) (2-0.18 dia. Intake) Lead wire length300±30 20 (11.8±1.2) (0.79) 41.7(1.64) Centrifugal E0720H24B8AP-00 ● Lead wire type Centrifugal Static pressure E0720H24B7AZ-00 ■ External dimensions in mm (inches) 33.2 (1.31) 250 E0720H24B5AZ-00 ■ Standard airflow and static pressure characteristics (At rated voltage) 75.1(2.96) E0720H...B8 26±0.3 (1.024±0.012) 26±0.3 (1.024±0.012) E0720H12B8AZ-00 Standard Carton 150 to a carton of (450 x 380 x 295) mm, mass 8 kg Fan model code (Pa) 300 E0720H12B8AS-00 Common Elec. Spec. See pages G-11, G-12, G-13. [By double chamber method] 42.2 (1.66) E0720H12B8AP-00 Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset Axial ・ Suitable for equipment that prioritizes high airflow over high static pressure. Motor DC fans Axial DC fans E0720H12B7CZ-00 ■ Standard airflow and static pressure characteristics (At rated voltage) 76.5 (3.01) E0720H12B7AZ-00 Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing 31±0.3 (1.22±0.012) E0720H12B5AZ-00 ・ Dimensions almost equivalent to those of E0720H, yet features higher airflow and lower noise. Materials Used 24.9 (0.98) E0720H12B5AS-00 31±0.3 (1.22±0.012) Silent E0720H12B5AP-00 ■ Features ■ General specification Silent ● Life expectancy of the E0720H-8 series in continuous operation at rated voltage is 20,000 hours at an operating temperature of 60℃. (25,000 hours for other products) Max. airflow: 0.29 m /min Max. static pressure: 300 Pa Mass: 50 g 3 Static pressure □70×20 (□2.8"×0.8") Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers Brushless DC Fans & Blowers SMBD series □ 76 × 25 mm ■ Standard specification SMB BLOWER m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB 11.6 180 0.72 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Speed min−1 48 4500 4.0 12 7.2-13.8 330 820 SMBD12H4 4.4 24 12-27.6 190 440 SMBD24H4 12 7.2-13.8 230 550 SMBD12Z4 24 12-27.6 120 350 SMBD24Z4 12 7.2-13.8 180 450 SMBD12B4 24 12-27.6 90 250 SMBD24B4 0.27 9.5 118 0.47 43 3800 2.7 0.24 8.5 88 0.35 41 3400 2.2 Operating Temp. Range ℃ Model Code MBDC series □ 76 × 30 mm DC Centrifugal Blowers ■ Standard specification MB BLOWER m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB 0.33 172 11.6 10.2 0.29 117 0.69 0.47 47 41 Speed min−1 4200 3400 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting 4.6 3.1 -20 ∼ +60 0.25 83 8.8 0.33 38 3000 2.5 Operating Temp. Range ℃ Model Code 12 7.2-13.8 380 820 MBDC12H4 12 7.2-13.8 250 550 MBDC12Z4 24 12-27.6 140 350 MBDC24Z4 12 7.2-13.8 200 450 MBDC12B4 24 12-27.6 110 250 MBDC24B4 -20 ∼ +60 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. □76×30 (□3.0"×1.2") ■ General specification MBDC12B4 Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset SMBD12B4S Common Elec. Spec. See pages G-11, G-12, G-13. SMBD12H4 Standard Carton 120 to a carton of (450 x 380 x 300) mm, mass 9 kg MBDC12Z4P MBDC12Z4S ● Lead wire type MBDC24B4 SMBD24Z4 SMBD24Z4S SMBD...Z4 75.7(2.98) Static pressure SMBD24H4S 120 80 40 SMBD...B4 0 0 0.1 0.2 0.3 Airflow (m3/mi n) 0.4 2-φ 4.5 (Through hole) (2-0.18 dia. HOLES) Outlet 24.1±0.3 (0.949±0.012) 38.1 (1.5) Intake MBDC24Z4S MBDC...H4 120 MBDC...Z4 80 40 0 MBDC...B4 0 DC centrifugal blower with sensor 12 V 24 V Model Code MBDC12B4S MBDC24B4S MBDC12Z4S MBDC12Z4P MBDC24Z4S MBDC12H4S ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● Customizing to the sleeve bearing specification also accepted depending on the intended purchase quantity. Contact Japan Servo for further information. ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Sensor Spec. G-15 G-49 Option Option G-15 Centrifugal Centrifugal Sensor Spec. Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black Power source (-): Black Rated Vol. SMBD12H4S SMBD12H4P SMBD24H4S SMBD24H4P 38.1 (1.50) Axial When sensor is installed SMBD12Z4S SMBD12Z4P SMBD24Z4S 24.1±0.3 (0.949±0.012) AC fans Axial AC fans When sensor is installed SMBD12B4S SMBD12B4P SMBD24B4S 2-φ 4.5 (Through hole) (2-0.18 dia. HOLES) ■ Wiring connection diagram Sensor output: Yellow Model Code Outlet 0.4 Intake 75.7 (2.98) Sensor output: Yellow ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). G-48 0.3 0.2 Airflow (m3/mi n) Power source (+): Red Rated Vol. 24 V 0.1 Power source (+): Red DC centrifugal blower with sensor 30 (1.18) Silent Silent Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black 21.6±0.3 (0.850±0.012) φ 50.5 (Intake inside dia.) (1.99 dia. Intake) 160 Power source (-): Black 12 V Lead wire length 300±30 (11.8±1.2) 75.7 (2.98) ■ Wiring connection diagram ● Lead wire type Centrifugal Centrifugal SMBD24H4P 40.7 (1.60) 160 SMBD24H4 (Pa) 200 39.9 (1.57) SMBD...H4 25 (0.98) 21.6±0.3 (0.850±0.012) 36.2±0.3 (1.425±0.012) SMBD24B4 ■ External dimensions in mm (inches) [By double chamber method] MBDC24Z4 30.9±0.3 (1.217±0.012) Lead wire length 300±30 (11.8±1.2) φ 50.5 (Intake inside dia.) (1.99 dia.Intake) 200 SMBD24B4S ■ Standard airflow and static pressure characteristics (At rated voltage) Axial ■ External dimensions in mm (inches) MBDC24B4S (Pa) SMBD12Z4S Standard Carton 120 to a carton of (450 x 380 x 300) mm, mass 13 kg MBDC12Z4 [By double chamber method] SMBD12Z4P Common Elec. Spec. See pages G-11, G-12, G-13. MBDC12H4 DC fans Axial DC fans SMBD12Z4 MBDC12B4S MBDC12H4S SMBD12H4C ■ Standard airflow and static pressure characteristics (At rated voltage) Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset 30.9±0.3 (1.217±0.012) Motor SMBD12H4S Motor Fan model code SMBD12B4P SMBD12H4P Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing 40.7 (1.60) SMBD12B4 Materials Used 40 (1.57) Materials Used Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing ■ General specification Silent Silent Fan model code Max. airflow: 0.33 m3/min Max. static pressure: 172 Pa Mass: 105 g 75.7 (2.98) 36.2±0.3 (1.425±0.012) Max. airflow: 0.33 m /min Max. static pressure: 180 Pa Mass: 95 g ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. 3 Static pressure □76×25 (□3.0"×1.0") Fans & Blowers Fans & Blowers DC Centrifugal Blowers 0.33 Brushless DC Fans & Blowers E0818K series Super Silent Blowers ■ Standard specification E0818K m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB Brushless DC Fans & Blowers □ 87 × 18 mm Speed Voltage Spec. V Current mA min−1 Rating Operating Range Rating Starting Model Code Operating Temp. Range ℃ DC Centrifugal Blowers ■ Standard specification SFB BLOWER m3/min CFM Speed min−1 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting Model Code 12 7.2-13.8 650 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. 7.9 24 12-27.6 330 810 SFBD24H7 ● The characteristics are the values at rated voltage (12 V), and normal temperature and humidity. 5.0 12 7.2-13.8 440 1120 SFBD12Z7 5.5 24 12-27.6 300 600 SFBD24Z7 12 7.2-13.8 290 630 SFBD12B4 24 12-27.6 150 330 SFBD24B4 9.2 240 0.96 38 3100 12 4.5-13.2 210 410 E0818K12B5AZ-00 -20 ∼ +70 ■ General specification Max. airflow: 0.26 m /min Max. static pressure: 240 Pa Mass: 60 g Max. Airflow Max. Static Pressure Noise Pa inH2O dB 7.8 0.26 □87×18 (□3.4"×0.7") SFBD series □ 94 × 30 mm Materials Used 3 Motor Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset 53 3900 20 200 0.80 49 3300 0.44 16 120 0.48 45 2700 3.5 1600 SFBD12H7 -20 ∼ +60 ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. ● The life expectancy of SFBD-H speed products at rated voltage and in continuous operation is 30,000 hours at 60 ℃. (40,000 hours for other products) Max. airflow: 0.65 m3/min Max. static pressure: 280 Pa Mass: 135 g ■ General specification Materials Used Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing SFBD12B4P Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset SFBD12B4S SFBD12H7 SFBD12H7P SFBD12H7S Standard Carton 60 to a carton of (450 x 380 x 220) mm, mass 9 kg ■ Standard airflow and static pressure characteristics (At rated voltage) ■ External dimensions in mm (inches) ● Lead wire type [By double chamber method] Axial SFBD12Z7P Common Elec. Spec. See pages G-11, G-12, G-13. DC fans Axial DC fans SFBD12Z7 Silent Silent [By double chamber method] 1.13 0.56 SFBD12B4 ■ Standard airflow and static pressure characteristics (At rated voltage) 280 □94×30 (□3.7"×1.2") Fan model code E0818K12B5AZ-00 23 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. Common Elec. Spec. See pages G-11, G-12, G-13. Fan model code 0.65 Operating Temp. Range ℃ Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers SFBD12Z7S SFBD24B4 SFBD24B4S SFBD24H7 Centrifugal Centrifugal SFBD24H7C SFBD24H7P SFBD24H7S ■ External dimensions in mm (inches) SFBD24Z7 ● Lead wire type SFBD24Z7P SFBD24Z7S Silent Silent ■ Wiring connection diagram Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black Axial AC fans Axial AC fans Lead wire spec. AWG26 UL3265 Color (+) Red ( - ) Black Centrifugal Centrifugal ■ Wiring connection diagram DC centrifugal blower with sensor Rated Vol. 12 V 24 V Model Code SFBD12B4S SFBD12B4P SFBD24B4S SFBD12Z7S SFBD12Z7P SFBD24Z7S SFBD24Z7P SFBD12H7S SFBD12H7P SFBD24H7S SFBD24H7P G-50 Sensor Spec. G-15 G-51 Option Option ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● Customizing to the sleeve bearing specification also accepted depending on the intended purchase quantity. Contact Japan Servo for further information. ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). 520 2.09 55 5000 23 390 1.57 49 4000 0.57 20 315 1.27 47 3600 8.4-13.8 12 5.0-13.2 1000 2200 E1027H12BAAZ-00 780 2400 E1027H12B8AZ-00 550 ■ Standard specification E1033H/Y m3/min CFM -20 ∼ +60 Max. Airflow Max. Static Pressure Noise Pa inH2O dB Speed Voltage spec. V Current mA min−1 Rating Operating Range Rating Starting 1.30 46 800 3.22 62 5800 1.19 42 630 2.53 60 5300 1.14 40 500 2.01 58 4850 0.85 30 320 1.29 50 3500 0.76 27 260 1.05 48 3100 0.64 23 185 0.74 -20 ∼ +70 1670 E1027H12B7AZ-00 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V), and normal temperature and humidity. ■ General specification Materials Used □97×33 (□3.8"×1.3") Max. airflow: 1.30 m3/min Max. static pressure: 800 Pa Mass: 140 g (∼8), 160 g (∼A), 170 g (∼C) Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset Motor E1033H12B5AM-04 ■ External dimensions in mm (inches) ● Lead wire type [By double chamber method] 200 4-φ 4.5 (Through hole) (4-0.18 dia. HOLES) 0 0.2 0.4 0.6 0.8 Airflow (m3/mi n) 120 1.0 5 (0.20) 37.6±0.3 (1.480±0.012) Lead wire length 300±30 (11.8±1.2) Outlet 32±0.3 (1.260±0.012) 39.5±0.3 49.5 (1.555±0.012) (1.95) 97.1 (3.82) 16-26.4 1250 2100 E1033H12BAAZ-00 630 1850 E1033H24BAAZ-00 12 4.5-13.2 770 24 9-226.4 390 12 5-13.2 590 24 10-26.4 300 12 5-13.2 400 24 10-26.4 220 12 5-13.8 250 24 10-26.4 120 1950 E1033H12B8AZ-00 940 E1033H24B8AZ-00 1260 E1033H12B7AZ-00 710 E1033H24B7AZ-00 -20 ∼ +70 820 E1033H12B6AM-04 400 E1033H24B6AZ-00 500 E1033H12B5AM-04 260 E1033H24B5AM-04 ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. E1033H12B8AZ-00 ■ General specification E1033H24B5AM-04 ■ External dimensions in mm (inches) Materials Used Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset E1033H24B6AZ-00 E1033H24B7AZ-00 Standard Carton 50 to a carton of (450 x 380 x 220) mm, mass 8 kg E1033Y12BBAS-00 ■ Standard airflow and static pressure characteristics (At rated voltage) E1033Y12BCAZ-00 (Pa) 800 E1033Y24BBAP-00 700 E1033Y24BBAS-00 600 E1033Y24BCAP-00 (1.260±0.012) 26±0.3 (1.024±0.012) 5 Lead wire length 300±30 (0.20) (11.8±1.2) φ52 (In (2.0 take ins ide 5dia .Inta dia.) ke ) 4-φ4.5 (Through hole) (4-0.18dia.HOLES) ● Terminal type (E1033H□□B□AM-04) E1033Y...BB (Note: Multi-sensor products with lock detection or pulse output, depending on the connection cord.) E1033H...BA E1033H...B8 26±0.3 (1.024±0.012) E1033H...B7 E1033H...B6 400 300 100 0 0 0.2 0.4 0.6 0.8 1.0 Airflow (m3/mi n) 1.2 1.4 31.5±0.3 (1.240±0.012) Intake 33 (1.30) Fan connection connector ZHR−4 (Mfd. by Japan Solderless Terminal) 320±10 Centrifugal Power source (-): Black Red (+V) Black (GND) Lead wire spec. AWG24 UL3266 Centrifugal 4321 When sensor is installed ・ Terminal output 1: (+) 2: ( - ) GND 3: S sensor output (Lock detection) 4: P sensor output (Pulse output) Lead wire ends are sheathed to protect the conductors. (Sheath peeling dimension 10 ±5) Super silent fan with sensor Rated Vol. Super silent fan with sensor Model Code 12 V E1027H12B7AS-00 E1027H12B7AP-00 ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 G-52 Sensor Spec. G-15 24 V Model Code E1033H12B5AM-04 E1033H12B6AM-04 E1033Y12BBAS-00 (note 1) (note 1) E1033Y12BBAP-00 E1033H24B5AM-04 E1033Y24BBAS-00 (note 1) E1033Y24BBAP-00 E1033Y12BCAS-00 E1033Y12BCAP-00 E1033Y24BCAS-00 E1033Y24BCAP-00 ● AM-04 becomes a lock detection sensor (S) type or pulse sensor (P) type in accordance with the connector connection method. Note 1: Purchase a sensor output cord (See page G-74) optionally available or the customer shall provide a cord with equivalent specifications if a sensor function is desired. ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 Sensor Spec. G-15 Options G-72, 73, 74 G-53 Option Option Rated Vol. 12 V Axial Axial AC fans Accessory cord (DCLD030ZT-ZZ01) This cord is supplied with the terminal type of (-04). Cords for S and P sensors also optionally available. (See page G-74.) Sensor output: Yellow or orange AC fans 39±0.3 50 (1.535±0.012) (1.97) 97.1 (3.82) Power source (+): Red Power source (-): Black Outlet 4-φ 4.5 (Through hole) (4-0.18 dia. HOLES) ■ Wiring connection diagram When sensor is installed 5 (0.20) 2 (In ta (2.0 ke ins id 5 dia . Inta e dia.) ke) 200 Sensor output: Yellow (1.260±0.012) φ5 E1033H...B5 E1033Y24BCAZ-00 Power source (+): Red 33 (1.30) 31.5±0.3 (1.240±0.012) 39±0.3 50 (1.535±0.012) (1.97) 97.1 (3.82) E1033Y...BC 500 Intake Outlet Silent Silent E1033Y24BCAS-00 Lead wire spec. AWG24 UL3266 Color (+) Red ( - ) Black 32±0.3 [By double chamber method] E1033Y12BCAS-00 E1033Y24BBAZ-00 ● Lead wire type (E1033H/Y) Common Elec. Spec. See pages G-11, G-12, G-13. E1033Y12BBAP-00 E1033Y12BCAP-00 ■ Wiring connection diagram 8.4-13.2 24 -20 ∼ +60 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. E1033Y12BBAZ-00 Lead wire spec. AWG24 UL3266 Color (+) Red ( - ) Black 2200 12 1450 3100 E1033Y12BBAZ-00 710 2700 E1033Y24BBAZ-00 E1033H12B7AZ-00 E1033H24BAAZ-00 25 (0.98) 39 12-26.4 E1033H12B6AM-04 E1033H24B8AZ-00 Intake 0.48 8.4-13.2 24 Centrifugal Centrifugal 100 40.4±0.3 (1.591±0.012) E1027H...B7 95 (3.74) 46.4±0.3 (1.827±0.012) Static pressure 0 (In ta (1.9 ke ins id 7 dia . Inta e dia.) ke) E1027H...B8 300 19 12 1850 3430 E1033Y12BCAZ-00 900 2830 E1033Y24BCAZ-00 Axial 25.5±0.3 (1.004±0.012) φ5 0 30.3 (1.19) (Speed A) 26.9 (1.06) (Speed 7.8) 31.5±0.3 (1.240±0.012) E1027H...BA 400 46 12-26.4 DC fans Axial DC fans (Pa) 600 500 0.53 E1033H12BAAZ-00 58 (2.28) E1027H12BAAZ-00 30.6±0.3 (1.205±0.012) E1027H12B8AZ-00 ■ Standard airflow and static pressure characteristics (At rated voltage) 53.4 (2.10) E1027H12B7AZ-00 2600 Fan model code Common Elec. Spec. See pages G-11, G-12, G-13. E1027H12B7AP-00 E1027H12B7AS-00 43 8.4-13.2 24 Silent Silent Fan model code Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing 12 95 (3.74) 45±0.3 (1.772±0.012) Max. airflow: 0.78 m3/min Max. static pressure: 520 Pa Mass: 125 g (∼8), 150 g (∼A) Static pressure □97×25 (□3.8"×1.0") Operating Temp. Range ℃ Model Code 58 (2.28) 28 0.64 Model Code Super Silent Fan 32±0.3 (1.260±0.012) 52 39±0.3 (2.05)(1.535±0.012) 58 (2.28) 0.78 Operating Temp. Range ℃ 32±0.3 (1.260±0.012) 39±0.3 (1.535±0.012) Speed Voltage Spec. V Current mA min−1 Rating Operating Range Rating Starting 52 (2.05) E1027H Max. Airflow Max. Static Pressure Noise m3/min CFM Pa inH2O dB 39±0.3 (1.535±0.012) ■ Standard specification E1033H/Y series 97 × 95 × 33 mm 39±0.3 (1.535±0.012) Super Silent Fan 97 × 95 × 25 mm 95 (3.74) 45±0.3 (1.772±0.012) E1027H series Brushless DC Fans & Blowers Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers E1232L series Super Silent Fan ■ Standard specification E1232L Max. Airflow Max. Static Pressure Noise m3/min CFM Pa inH2O dB 54 0.91 32 320 1.29 49 3100 0.83 29 250 1.01 47 2750 0.75 26 200 0.80 44 12 3800 2450 □119×32 (□4.7"×1.3") Max. airflow: 1.13 m3/min Max. static pressure: 460 Pa Mass: 220 g 1100 2100 E1232L12B9AZ-00 560 1900 E1232L24B9AZ-00 12 7.2-13.2 820 24 12-26.4 430 12 7.2-13.2 560 24 12-26.4 310 12 7.2-13.2 420 24 12-26.4 250 1800 E1232L12B7AZ-00 900 E1232L24B7AZ-00 1300 E1232L12B6AZ-00 700 E1232L24B6AZ-00 940 E1232L12B5AZ-00 490 E1232L24B5AZ-00 □126×32 (□5.0"×1.3") Max. airflow: 1.08 m3/min Max. static pressure: 480 Pa Mass: 250 g ● The life expectancy of E1232L-7, 9 speed products at rated voltage and in continuous operation is 30,000 hours at 60℃. (40,000 hours for other products) E1232L12B7AZ-00 Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset E1232L12B9AZ-00 Common Elec. Spec. See pages G-11, G-12, G-13. E1331K12B5AZ-00 E1331K12B7AZ-00 E1331K12B9AZ-00 E1331K24B5AZ-00 E1331K24B6AZ-00 E1331K24B7AZ-00 ● Lead wire type E1331K24B9AZ-00 E1232L...B6 E1232L...B5 200 100 0 Outlet 6-φ4.3 (Through hole) 5 44.6±0.3 (0.20)(6-0.17dia. HOLES) (1.756±0.012) 0 0.2 3400 0.87 31 310 1.25 49 2700 0.79 28 250 1.01 47 2500 0.72 25 210 0.84 45 2200 12 8.4-13.2 24 21-26.4 1100 1960 E1331K12B9AZ-00 530 1980 E1331K24B9AZ-00 12 6-13.2 690 24 12-26.4 380 12 6-13.2 490 24 12-26.4 280 12 6-13.2 440 24 12-26.4 240 -20 ∼ +60 1790 E1331K12B7AZ-00 930 E1331K24B7AZ-00 1400 E1331K12B6AZ-00 710 E1331K24B6AZ-00 -20 ∼ +70 1008 E1331K12B5AZ-00 520 E1331K24B5AZ-00 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. 1.0 1.2 Materials Used Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Motor Brushless DC motor, Protection type: Current shut off by detecting lock state, automatically reset 52±0.3 60.4 (2.047±0.012) (2.38) 119 (4.69) Common Elec. Spec. See pages G-11, G-12, G-13. ■ Standard airflow and static pressure characteristics (At rated voltage) ■ External dimensions in mm (inches) ● Lead wire type [By double chamber method] (Pa) 500 5 (0.20) 8 (0.32) E1331K...B9 400 Intake E1331K...B7 300 E1331K...B6 E1331K...B5 200 100 32 (1.26) Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black 0 Intake 0 0.2 0.8 0.4 0.6 Airflow (m3/mi n) 1.0 1.2 Outlet ■ Wiring connection diagram 31 (1.22) φ 55 (Intake inside dia.) (2.17 dia. Intake) 3-φ 4.5 (Through hole) (3-0.18 dia. HOLES) Lead wire length 300±30 (11.8±1.2) 54.4±0.3 50.4±0.3 (2.142±0.012) (1.984±0.012) 8 (0.32) 62 (2.44) 9 (0.35) 50.4±0.3 (1.984±0.012) 126 (4.96) Silent Silent 0.8 0.4 0.6 Airflow (m3/mi n) 37.1±0.3 (1.461±0.012) 46.5±0.3 (1.831±0.012) Static pressure 300 54 Centrifugal Centrifugal E1232L...B7 65.9 (2.59) E1232L...B9 Lead wire length 300±30 (11.8±1.2) 61 (2.40) 500 117 (4.61) 58.3±0.3 46.5±0.3 (2.594±0.012)(1.831±0.012) 50.9±0.3 41.1±0.3 (2.004±0.012)(1.618±0.012) 52±0.3 52.8±0.3 (2.047±0.012)(2.079±0.012) 44.6±0.3 43.4±0.3 (1.709±0.012) φ72 (Intake inside dia.) (1.756±0.012) 5 (0.20) (2.84dia.Intake) (Pa) 400 1.93 Axial ■ External dimensions in mm (inches) [By double chamber method] E1232L24B9AZ-00 480 Operating Temp. Range ℃ Model Code DC fans Axial DC fans ■ Standard airflow and static pressure characteristics (At rated voltage) E1232L24B7AZ-00 38 E1331K12B6AZ-00 E1232L24B5AP-00 E1232L24B6AZ-00 1.08 Fan model code Motor E1232L24B5AZ-00 Speed Voltage Spec. V Current mA min−1 Rating Operating Range Rating Starting ■ General specification ■ General specification E1232L12B6AZ-00 Max. Airflow Max. Static Pressure Noise Pa inH2O dB -20 ∼ +70 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. Materials Used E1232L12B5AZ-00 m3/min CFM -20 ∼ +60 ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing E1232L12B5AP-00 E1331K Silent Silent Fan model code 8.4-13.2 24 21.6-26.4 ■ Standard specification 63±0.3 41.8±0.3 (2.480±0.012) (1.646±0.012) 127 (5.00) 1.85 Model Code Super Silent Fan 16.5±0.3 (0.650±0.012) 460 Operating Temp. Range ℃ 75.4 (2.97) 70.2 (2.76) 40 Speed Voltage Spec. V Current mA min−1 Rating Operating Range Rating Starting E1331K series 126 × 127 × 31 mm Static pressure 1.13 119 × 117 × 32 mm Brushless DC Fans & Blowers Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers Lead wire spec. AWG24 UL1007 or UL3266 Color (+) Red ( - ) Black ■ Wiring connection diagram Power source (-): Black Axial Sensor output: Yellow Power source (+): Red AC fans Axial AC fans Power source (+): Red When sensor is installed Power source (-): Black or blue Centrifugal Centrifugal Super silent fan with sensor Rated Vol. Model Code 12 V 24 V E1232H12B5AP-00 E1232H24B5AP-00 G-54 Sensor Spec. G-15 ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 G-55 Option Option ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 2700 71 1.65 58 270 1.73 1.09 56 51 19.4 12 Model Code 8.4-13.8 1600 910 E1540H12B7AZ-00 17.8 24 16.8-27.6 740 430 E1540H24B7AZ-00 2200 13 Operating Temp. Range ℃ 12 8.4-13.8 1100 1640 E1540H12B5AZ-00 24 12-27.6 540 Super Silent Fan ■ Standard specification E2271Z m3/min CFM Max. Airflow Max. Static Pressure Noise Pa inH2O dB 18.1 639 650 -20 ∼ +70 ・ Large airflow, high static pressure backward blowers without housing. Common Elec. Spec. See pages G-11, G-12, G-13. Standard Carton 16 to a carton of (450 x 380 x 220) mm, mass 7 kg ■ Standard airflow and static pressure characteristics (At rated voltage) ● Lead wire type 47±0.3 (1.850±0.012) 500 47±0.3 (1.850±0.012) 152 (5.98) E1540H...B7 400 300 200 E1540H...B5 2-φ 4.5 (Through hole) (2-0.18 dia.HOLES) 100 0 0 1.0 2.0 3.0 Airflow (m3/mi n) Outlet 58.5±0.3 (2.303±0.012) 150 (5.91) 74 (2.91) E2271Z48B7AP-00 71 (2.80) Rotation 65 (2.56) (Pa) 800 Intake 600 400 Intake 200 0 0 4 8 12 n) Airflow (m3/mi 16 20 4-M4 Depth 6 (4-M4 DEPTH 0.23 MAX.) φ 58±0.15 Mounting screw hole pitch Discharge through entire periphery 40 (1.58) ■ Wiring connection diagram Lead wire spec. AWG24 UL3266 Color (+) Red ( - ) Black Centrifugal Centrifugal Static pressure Fan model code 91 (Intake inside dia.) (3.58 dia.Intake) E1540H24B7AZ-00 73.2 (2.88) E1540H24B7AS-00 Lead wire length 300±30 (11.8±1.2) ● Lead wire type [By double chamber method] (Performance when an inlet ring is combined) 84 (3.31) (Pa) ■ External dimensions in mm (inches) (P.C.D=2.283 dia. ±0.006) Lead wire spec. AWG24 UL3266 Color (+) Red ( - ) Black (sensor) Yellow Power source (+): Red Sensor output: Yellow Inlet ring 2 R2 20 1.5 ■ Wiring connection diagram Silent Silent φ155 When sensor is installed Power source (+): Red Axial E1540H24B7AP-00 ■ Standard airflow and static pressure characteristics (At rated voltage) DC fans Axial DC fans [By double chamber method] E1540H24B5AZ-00 Common Elec. Spec. See pages G-11, G-12, G-13. ・ A low noise effect can be achieved by combining an inlet ring. ■ External dimensions in mm (inches) 58.5±0.3 (2.303±0.012) E1540H24B5AP-00 Brushless DC motor, Protection type: Overcurrent detection and automatic resetting by current limiting 1. ■ Features E1540H12B7AP-00 E1540H12B7AZ-00 Motor ±0 0 0..7 7) Max. airflow: 18.1 m3/min Max. static pressure: 650 Pa Mass: 1300 g Brushless DC motor, Protection type: Overcurrent detection and automatic resetting by current limiting -20 ∼ +60 8 ((33. 800±± .22± 220 E1540H12B5AZ-00 Ventur: Aluminum alloy die castings Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing Static pressure E1540H12B5AP-00 Materials Used φ220×71 (φ8.7"×2.8") Motor 2100 4500 E2271Z48B7AP-00 Silent Silent Fan model code 36-57 ■ General specification ■ General specification Materials Used 48 ● The characteristics are the values at rated voltage (48 V), and normal temperature and humidity. ● The life expectancy of E1540H-7 speed products at rated voltage and in continuous operation is 30,000 hours at 60℃. (40,000 hours for other products) Venturi: ABS and PBT synthetic resins Impeller: ABS and PBT synthetic resins Bearing: Both side shielded ball bearing 3200 Operating Temp. Range ℃ 1450 E1540H24B5AZ-00 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. Max. airflow: 2.0 m3/min Max. static pressure: 430 Pa Mass: 380 g 71 Model Code ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● The characteristics are the values at rated voltage (12 V or 24 V), and normal temperature and humidity. □150×40 (□5.9"×1.6") 2.61 Speed Voltage Spec. V Current mA min−1 Rating Operating Range Rating Starting 2) 430 2.0 Input Voltage Spec. V Current mA W Rating Operating Range Rating Starting ) Speed min−1 (1 300 1. ± 8± 30 E1540H Max. Airflow Max. Static Pressure Noise m3/min CFM Pa inH2O dB φ 99 (3.90 dia.) ■ Standard specification φ 161 (6.34 dia.) Super Silent Fan E2271Z series φ220 × 71 mm φ 222 (8.74 dia.) E1540H series 150 × 152 × 40 mm Brushless DC Fans & Blowers Fans & Blowers Fans & Blowers Brushless DC Fans & Blowers Power source (-): Black Sensor output: Yellow Blower With an inlet ring installed (S = N.T.S.) Options (sold separately) ・E2271 inlet ring Centrifugal Centrifugal Super silent fan with sensor Super silent fan with sensor Rated Vol. Model Code 12 V E1540H12B5AP-00 E1540H12B7AP-00 E1540H24B5AP-00 E1540H24B7AS-00 E1540H24B5AP-00 24 V G-56 Sensor Spec. G-15 Model Code 48 V E2271Z48B7AP-00 ● This product features a large airflow and high static pressure without using a housing. A standard specification is ensured if installed complying with the foregoing bell mouth shape and its position. ● See page G-73 for detailed dimensions of the intake bell mouth. ● A bell mouth fitting accessory (product code E2271 Inlet Ring) is available as an option. (See page G-73.) ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 Sensor Spec. G-15 Options G-72, 73, 74 G-57 Option Option ● Japan Servo can meet many of your requirements for customization, such as special connectors, other sensors not listed above, variable speed specifications, and other modifications. Please contact Japan Servo during your product planning and development stage. ● The listed products are registered in the following overseas standards files, UL: E48889, CSA: LR49399, TUV: R9451586 ● An electronic version of the Japan Servo catalog can be forwarded upon request. 3D data is also available at our web2-CAD site (www.web2cad.co.jp). Rated Vol. Axial Power source (-): Black Products for variable-speed operation by PWM, voltage or resistance value commands can also be supplied with this model. (See pages G-58 and 59.) Contact Japan Servo for further information. AC fans Axial AC fans When sensor is installed Brushless DC Fans & Blowers Fan model code ■ Lineup of PWM variable-speed semi-standard products ■ Fully customized products D1238B48B7ZP-00 ● A PWM signal from the customer equipment is input to the control line (blue) of the fan motor for variable-speed operation of fans and blowers. (Input and noise can be reduced when the internal temperature of the customer equipment is low, such as during idling.) Fully customized products will be manufactured to optimally match your equipment for high volume needs. (more than 10,000 units/month) for home appliances such as refrigerators, air conditioners and washing machines and for industrial machinery and information communication equipment, including open showcases, power sources and computer-related equipment. Please contact Japan Servo for more information. G0938B12BAZP-00 G0938B24BAZP-00 G0938B48BAZP-00 G0938B12B9ZP-00 G0938B24B9ZP-00 G0938B48B9ZP-00 ● Sizes Axial fans: □60 mm∼□172 mm Blower: □70 mm∼φ220 mm Customized and Semi-Customized Fans & Blowers G1238B12BBZP-00 G1238B48BBZP-00 G1238B24BAZP-00 G1238B48BAZP-00 G1751M48B9ZP-00 G1751M48B8ZP-00 G1751M48B6ZP-00 G1751M48B5ZP-00 E2271Z48B7ZP-00 (The characteristics are typical characteristics and their curves will differ, depending on the particular model) ● Standard values for PWM control signal - speed specification (at rated voltage, open, and normal temperature and humidity) I out V out VL0sat Freq. 5000 vcc I out Semi-customized products, including the following, will be manufactured by combining a large variety of components available to Japan Servo. Please contact Japan Servo for more information. 3000 2000 V out 0 0 10 20 30 40 50 60 70 80 90 100 Hi Duty (%) ■ Semi-standard products (Products in regular production) Model Code □120×38 mm D1238B48B7ZP-00 Max. Airflow Max. Static Pressure Voltage Spec. V Operating Min. Rating Operating Range Temp. Range ℃ Speed m3/min CFM Pa inH2O Noise dB 4.4 155 170 0.68 54 4000 1250 48 40.8∼55.2 -20 ∼ +70 3.9 138 490 1.97 63 7500 2100 24 16.8∼26.4 -20 ∼ +60 Max. 12 G0938B12BAZP-00 G0938B24BAZP-00 48 36∼52.8 G0938B12B9ZP-00 12 8.4∼13.8 440 1.77 61 36∼55.2 12 9.6∼13.8 261 520 2.09 67 ● Tray units fitted with a standard or semi-customized fans. ● Tray shape designed, manufactured and tailored to customer specifications. 7000 2000 24 16.8∼27.6 -20 ∼ +60 48 7.4 ■ Fan tray units Silent Silent 127 G1238B12BBZP-00 6300 1000 24 16.8∼27.6 -20 ∼ +60 G1238B48BBZP-00 48 G1238B24BAZP-00 24 16.8∼27.6 415 1.67 64 5300 1000 G1751M48B9ZP-00 11.2 395 840 3.37 76 6800 3200 G1751M48B8ZP-00 10.0 353 710 2.85 71 6200 2600 G1751M48B7ZP-00 9.2 325 580 2.33 69 5600 2000 48 G1751M48B6ZP-00 8.3 293 490 1.97 66.5 5100 1500 G1751M48B5ZP-00 7.3 258 360 1.45 63 4500 1500 E2271Z48B7ZP-00 18.1 639 650 2.61 71 3200 1000 48 48 36∼55.2 Fan tray unit example 1 Fan tray unit example 2 Fan unit example -20 ∼ +60 Axial AC fans 36∼50.4 -20 ∼ +50 36∼60 -20 ∼ +60 36∼57 -20 ∼ +60 Axial 223 36∼55.2 AC fans 6.3 G1238B48BAZP-00 φ220×71 mm 3.6 G0938B48B9ZP-00 G1238B24BBZP-00 φ172×150×51 mm 8.4∼13.2 G0938B48BAZP-00 G0938B24B9ZP-00 For operation in a high-temperature atmosphere of 80 ℃. Long life products (60,000 hours or longer at 60 ℃, 100,000 hours at 50 ℃) Energy saving products (30 % to 50 % less input compared with conventional products) IP55 products (Outdoor installation and in a high-humidity environment) Variable-speed products (PWM, voltage or resistance value command), dual-speed products Fans for high static pressure regions (92 mm sq. x 38 mm thick, 120 mm sq. x 38 mm thick, 172 mm dia. x 51 mm thick and others) 7) Fans to prevent galvanic corrosion of ball bearings (ceramic ball specification) Centrifugal Centrifugal Size 1) 2) 3) 4) 5) 6) Axial Min setting or stop DC fans Axial DC fans 1000 (PWM) □120×38 mm Fully customized product example 3 ■ Semi-customized products 4000 Hi Duty □92×38 mm Fully customized product example 2 6000 1 mA MAX. Supply volt. MAX. 0.4 MAX. 2000 Hz∼5000 Hz Fan Fully customized product example 1 Silent Silent G1751M48B7ZP-00 ■ Characteristics for reference Speed (RPM/min) G1238B24BBZP-00 Fans & Blowers Fans & Blowers Variable-Speed Fans and Blowers Brushless DC Fans & Blowers Centrifugal Centrifugal Option Option ● The lineup of variable-speed fans and blowers will be expanded regularly. Visit the Japan Servo Website for information on the latest lineup. ● Direct your inquiry to Japan Servo for connector termination to lead wires, for sensor specifications other than those contained in the catalog and for variable speed specifications. (Products tailored to voltage command control and resistance value command control are also available) ● To ensure correct installation and smooth operation please obtain a drawing for approval or reference drawing from Japan Servo Co. G-58 G-59 AC Axial Fans & Blowers SCNA series AC Silent Fan ■ Standard specification AC Silent Fan ■ Standard specification AC Silent 25 m3/min CFM AC Silent m3/min CFM Max. Airflow Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min 100 200 2350/ 2750 34/ 39 1.9/ 2.2 67/ 78 41/ 45 0.17/ 0.18 1.2/ 1.45 42/ 51 15/ 22 0.06/ 24.5/ 1500/ 100-120 50/ 1900 200-240 60 0.09 29 50/ 60 115 208-230 Input W Model Code Current Lock mA Current mA Lead Wire Type Std* Lead Wire Type Std* 13/11 190/140 190/165 SCUA55B5 13.5/11 160/130 175/150 SCUA2B5 14/11 14/11 90/75 90/70 15/11.5 90/65 80/60 SCUA48F5 100 14/12 200/180 300/270 SCNA55B5 P 100 15/13 200/180 300/270 14/12 110/ 90 155/135 SCNA60B5 0.32/ 0.32 80/ 80 92/ 109 2.6/ 3.1 38/ 42 200 2800/ 3300 15/13 110/ 90 155/135 115 16/13 200/170 300/260 SCNA2B5 UC (U) SCUJ48F5 P 208-230 14/13 110/ 90 160/140 SCNA52B5 UC 100-120 9/8.5 110/ 90 110/ 95 SCNA47D5 UC 8.5/8 110/ 90 110/ 95 9/8.5 60/ 50 60/ 50 SCNA48D5 8.5/8 60/ 50 60/ 50 200 □120×38 (□4.7"×1.5") ● *Products conforming to the specifications of the Electrical Appliance and Material Safety Law (Japan) can be used in case the products are assembled in electric appliances Max. airflow: 2.6 m3/min (50 Hz) 3.1 m3/min (60 Hz) Max. static pressure: 80 Pa (50 Hz) 80 Pa (60 Hz) Mass: 550 g used in Japan. (Products marked with the (PS)E mark) ■ General specification SCUA2B5 Fan model code SCNA47D5 200-240 Usage Range SCUJ47F5 Operating Temp. Range -20 ℃ ∼ +60 ℃ SCUJ48F5 Standard Carton 30 to a carton of (560 x 300 x 190) mm, mass 10 kg SCNA52B5 The guard for the intake side (SCU guard) can be mounted with one touch without using a tool. Rated voltage ±10 % used in Japan. (Products marked with the (PS)E mark) ■ General specification Venturi: Aluminum alloy die casting Propeller: Glass fiber reinforced polycarbonate resin Bearing: Double - sided shielded ball bearing Motor Shaded pole induction motor Protection type: Impedance protection SCNA55B5 SCNA60B5 SCNJ47D5 SCNJ48D5 Common Elec. Spec. See pages G-12. SCNJ55B5 Usage Range SCNJ60B5 Operating Temp. Range -20 ℃ ∼ +60 ℃ ■ Standard airflow and static pressure characteristics (At rated voltage) 20 50 Hz 10 50 Hz ● Lead wire type 25.5±0.5 (1.0±0.02) 0 3 50 Hz Airflow (m3/mi n) 1 2 ■ External dimensions in mm (inches) □120 (4.72 sq.) □104.8 (4.126 sq.) □104.8±0.3 (4.126 sq.±0.012) 8 12 .) φ dia (5 3 Airflow (m3/mi n) ■ Mounting hole dimensions in mm (inches) [Recommendation] 38.5±0.5 4 (1.5±0.02) (0.16) 10 (0.39) 3 (11 00± .8± 30 1.2 ) φ 128 (5 dia.) 3 (11 00± .8± 30 1.2 ) 2 □117 (4.61 sq.) □104.8 (4.126 sq.) 8 12 .) φ dia (5 4 -φ 4.5 (8-0.18 dia.) Outlet side 4-φ 4.5 (8-0.18 dia.) Rotation 4 -φ 4.5 (8-0.18 dia.) Lug for guard mounting Outlet side Airflow Lead wire specification SCNJ series: Heat resistant PVC 0.75 mm2 (30 conductors, 0.18 dia.) SCNA series: AWG22 UL1015 Option Option G-72, 73, 74 ■ Mounting hole dimensions in mm (inches) [Recommendation] 1 Centrifugal Airflow Lead wire specification SCUJ series: Heat resistant PVC 0.75 mm2 (30 conductors, 0.18 dia.) SCUA series: AWG22 UL1015 Options (sold separately) ・Guard: F120UL guard (Outlet side) ・Guard: SCU guard (Intake side) 0 10 50 Hz Axial Centrifugal Rotation 20 60 Hz 20 □117 (4.61 sq.) Lug for guard mounting 4-φ 4.5 (8-0.18 dia.) 40 30 AC fans Axial AC fans □104.8±0.3 (4.126 sq.±0.012) 1.5 60 Hz 60 ● Lead wire type 10 (0.39) 4 (0.16) 1 0.5 Airflow (m3/mi n) 80 Silent Silent 3 ■ External dimensions in mm (inches) □120(4.72 sq.) (Pa) 100 0 1 2 Airflow (m3/mi n) Options (Pa) 60 Hz Static pressure 60 Hz 30 SCN□□D5 20 Static pressure Static pressure Static pressure SCN□□B5 40 Centrifugal Centrifugal ■ Standard airflow and static pressure characteristics (At rated voltage) (Pa) 0 G-60 The guard for the intake side (SCN guard) can be mounted with one touch without using a tool. Rated voltage ±10 % Standard Carton 20 to a carton of (565 x 310 x 180) mm, mass 11.5 kg SCU□□F5 50 10 ●Guard mounting Materials Used SCUJ60B5 (Pa) P ● *Products conforming to the specifications of the Electrical Appliance and Material Safety Law (Japan) can be used in case the products are assembled in electric appliances SCUJ55B5 SCU□□B5 SCNJ48D5 Axial SCUA55B5 P DC fans Axial DC fans Common Elec. Spec. See pages G-12. SCNJ47D5 UC ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. SCNA48D5 SCUA52B5 1890/ 100-120 50/ 2030 200-240 60 P SCNA2B5 Shaded pole induction motor Protection type: Impedance protection Motor SCUA48F5 28/ 31 SCNJ60B5 ● *The symbols in the standards column denote that they are registered in the following standards files, U: UL E48889, C: CSA LR49399, LR108118 Venturi: Aluminum alloy die casting Propeller: Glass fiber reinforced polycarbonate resin Bearing: Double - sided shielded ball bearing Materials Used SCUA47F5 ●Guard mounting 0.10/ 0.11 25/ 26 60/ 67 1.7/ 1.9 P Silent Silent Fan model code ● *(U) in the standards column denotes products conforming to UL standard (certification not obtained as yet). SCNJ55B5 UC P φ 128 (5 dia.) Max. airflow: 1.9 m3/min (50 Hz) 2.2 m3/min (60 Hz) Max. static pressure: 41 Pa (50 Hz) 45 Pa (60 Hz) Mass: 330 g 50/ 60 UC (U) SCUJ47F5 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. □120×25 (□4.7"×1.0") Model Code Current Lock mA Current mA Lead Wire Type Std* Lead Wire Type Std* P (U) SCUA52B5 Input W SCUJ60B5 (U) 15/11.5 170/130 175/130 SCUA47F5 Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min (U) SCUJ55B5 100/85 90/70 Max. Airflow □ 120 × φ128 × 38 mm Fans & Blowers Fans & Blowers SCUA series □ 120 × φ128 × 25 mm AC Axial Fans & Blowers Options (sold separately) ・Guard: F120UL guard (Outlet side) ・Guard: SCN guard (Intake side) Options G-72, 73, 74 G-61 AC Axial Fans & Blowers WE series □ 92 × 25 mm AC Axial Fan ■ Standard specification AC Axial Fan ■ Standard specification VENUS 25 m3/min CFM KOALA 25 m3/min CFM Max. Airflow 0.55 /0.65 Input W Model Code Current Lock mA Current mA Lead Wire Type Std* Lead Wire Type Std* 100 11/9 130/110 130/110 VE55B5 200 11/8.5 Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min 42/ 60 19 /23 2750/ 3300 30/ 35 0.17/ 0.24 115 208-230 115 □80×25 (□3.2"×1.0") Max. airflow: 0.55 m3/min (50 Hz) 0.65 m3/min (60 Hz) Max. static pressure: 42 Pa (50 Hz) 60 Pa (60 Hz) Mass: 250 g 0.56/ 0.68 20 /24 45/ 66 0.18/ 0.27 30/ 35 0.37/ 0.48 13 /17 17/ 29 0.07/ 0.12 27/ 31 50/ 60 2750/ 220/230 3300 1.7/ 3.0 100-120 50/ 200-240 60 11/9 80/ 70 130/100 170/130 VE2B5 11/10 11/9 70/ 60 70/ 60 75/ 65 VE50B5 P 100 11/9 130/110 140/130 WE55B5 VEJ60B5 P 100 9/7.5 130/110 140/130 WEJ55B5 200 12/10 70/ 60 80/ 75 WE60B5 200 12/10 70/ 60 80/ 75 WEJ60B5 UTV TV VEJ47F5 P □92×25 (□3.6"×1.0") TV VEJ48F5 P Max. airflow: ● *Products conforming to the specifications of the Electrical Appliance and Material Safety Law (Japan) can be used in case the products are assembled in electric appliances Motor Shaded pole induction motor Protection type: Impedance protection VE48F5 VE50B5 0.85 m3/min (50 Hz) 1.0 m3/min (60 Hz) Max. static pressure: 49 Pa (50 Hz) 67 Pa (60 Hz) Mass: 290 g 10/8 0.85/ 1.0 30/ 35 52/ 74 0.21/ 0.30 35/ 40 2700/ 220/230 3200 0.55/ 0.68 19/ 24 19/ 27 0.07/ 0.11 25/ 30 100-120 1750/ 50/ 100-120 1750 60 200-240 11/10 140/110 150/120 WE115B5 80/ 70 90/ 80 WE50B5 120/110 120/110 WE47F5 12/10 120/110 120/110 WEJ47F5 80/ 60 WE47F5 WE48F3 Venturi: Aluminum alloy die casting Propeller: Glass fiber reinforced polycarbonate resin Bearing: Double - sided shielded ball bearing Shaded pole induction motor Protection type: Impedance protection Motor VEJ47F5 Operating Temp. Range -20 ℃ ∼ +60 ℃ WE52B3 Common Elec. Spec. See pages G-12. VEJ48F5 Standard Carton 40 to a carton of (450 x 380 x 160) mm, mass 11 kg WE52B5 Usage Range WE55B3 ■ Standard airflow and static pressure characteristics (At rated voltage) Operating Temp. Range -20 ℃ ∼ +60 ℃ WE55B5 Standard Carton 40 to a carton of (480 x 380 x 160) mm, mass 12 kg VE□□B5 VE□□F5 WE60B3 (Pa) (Pa) WE60B5 ■ Standard airflow and static pressure characteristics (At rated voltage) 40 WEJ47F5 WE□□B□ 30 WEJ55B5 0 0.4 0.8 Airflow (m3/mi n) 1.2 0.2 0.4 Airflow (m3/mi n) ■ External dimensions in mm (inches) ● Lead wire type 25.5±0.5 (10±0.02) □80 (3.15 sq.) 8-φ 4.5±0.3 (8-0.18 dia.) Airflow Options (sold separately) ・Guard: F80UL guard ・Filter: F80 filter 0 1.2 50 HZ 0.4 0.8 Airflow (m3/mi n) 1.2 ● Lead wire type (WE□□□5) ● Terminal type [2 terminals: with grounding tap] (WE□□□3) 25.5±0.5 (1.0±0.02) □92 (3.62 sq.) □82.5 ±0.3 (3.248 sq.±0.013) 300±30 (11.8±1.2) 3.7 (0.15) 3.7 (0.15) Grounding tap M4 through hole Rotation 8-φ 4.5±0.3 (8-0.18 dia.) Airflow Lead wire specification WEJ series: Heat resistant PVC 0.75 mm2 (30 conductors, 0.18 dia.) WE series: AWG22 UL1015 ■ Mounting hole dimensions in mm (inches) [Recommendation] Options (sold separately) ・Guard: F92UL guard ・Filter: F92 filter ・Power code: T2P1 code, D2P1 code, UL2P1 code Option Option G-62 0.4 0.8 Airflow (m3/mi n) ■ External dimensions in mm (inches) □77 (3.03 sq.) Identical for the intake and outlet sides Lead wire specification VEJ series: Heat resistant PVC 0.75 mm2 (30 conductors, 0.18 dia.) VE series: AWG22 UL1015 10 50 HZ □71.5 (2.815 sq.) 4 -φ 4.5 (8-0.18 dia.) 60 HZ 20 Centrifugal Centrifugal Rotation 20 0 87 .) φ dia 3 4 . (3 30 ) 0± 30 ±1.2 .8 (11 40 30 Axial Axial AC fans 3.5 (0.14) Grounding tap M4 through hole 60 HZ AC fans 3.5 (0.14) □71.5±0.3 (2.815 sq.±0.013) 40 60 0.6 ■ Mounting hole dimensions in mm (inches) [Recommendation] (Pa) 80 Static pressure 50 Hz WE□□F□ Silent Silent 0 10 ℃ ∼ +55 ℃ in standard ( -20 -20 ℃ ∼ +40 ℃ in VDE standard ) (Pa) Static pressure Static pressure Static pressure 20 WEJ60B5 60Hz 60 Hz 20 Rated voltage ±10 % Centrifugal Centrifugal 60 Hz Axial Materials Used WE50B5 40 UP used in Japan. (Products marked with the (PS)E mark) WE48F5 60 WE48F3 ■ General specification Usage Range 50 Hz UP P ● *Products conforming to the specifications of the Electrical Appliance and Material Safety Law (Japan) can be used in case the products are assembled in electric appliances VE60B5 80 UTV WE47F3 ● *The symbols in the standards column denote that they are registered in the following standards files, U: UL E48889, T: TUV R60229-60302, V: VDE 3019UG Common Elec. Spec. See pages G-12. VEJ60B5 UTV 80/ 60 WE48F5 VE55B5 VEJ55B5 UCP UTV WE115B5 WE47F3 ℃ ∼ +55 ℃ in standard ( -20 -20 ℃ ∼ +40 ℃ in VDE standard ) UCP UC WE52B3 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. WE2B5 Rated voltage ±10 % UC WE2B3 Fan model code WE2B3 UCP P 75/ 70 WE52B5 12/10 12/10 UC WE60B3 120/100 140/120 WE2B5 70/ 60 UCP P DC fans Axial DC fans VE52B5 11/9 11/10 UC WE55B3 Silent Silent ■ General specification Materials Used 50/ 60 115 115 used in Japan. (Products marked with the (PS)E mark) VE47F5 2700/ 3200 35/ 40 UTV ● *The symbols in the standards column denote that they are registered in the following standards files, U: UL E48889, T: TUV R60229-60302, V: VDE 3019UG Venturi: Aluminum alloy die casting Propeller: Glass fiber reinforced polycarbonate resin Bearing: Double - sided shielded ball bearing 0.20/ 0.27 208-230 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. VE2B5 49/ 67 30/ 35 0.85/ 1.0 U Fan model code VE115B5 Model Code Current Lock mA Current mA Lead Wire Type Std* Terminal Type Std* VEJ55B5 70/ 60 VE48F5 70/ 60 Input W U 130/110 130/110 VE47F5 12/10 Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min U U 75/ 65 VE52B5 140/110 140/110 VE115B5 9/8 12/10 80/ 75 VE60B5 Max. Airflow Fans & Blowers Fans & Blowers VE series □ 80 × 25 mm AC Axial Fans & Blowers G-63 AC Axial Fans & Blowers CU series □ 120 × 25 mm AC Axial Fan ■ Standard specification AC Axial Fan ■ Standard specification KOALA MARKII m3/min CFM CENTAUR 25 m3/min CFM Max. Airflow Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min 100 100 1.1/ 1.3 □92×38 (□3.6"×1.5") Max. airflow: 1.1 m3/min (50 Hz) 1.3 m3/min (60 Hz) Max. static pressure: 62 Pa (50 Hz) 80 Pa (60 Hz) Mass: 450 g KA2B3 28/ 32 62/ 80 29/ 36 0.25/ 0.32 0.12/ 0.15 31/ 38 26/ 28 2850/ 3300 200 50/ 60 200 Model Code Current Lock mA Current mA Lead Wire Type Std* Terminal Type Std* 8.5/8 200/160 200/160 KA55B4 KA60B3 UP 7/6 200/160 200/160 KAJ55B4 P 100/ 70 100/ 75 KA60B5 U 7/6 100/ 70 100/ 75 KAJ60B5 P 180/150 180/150 KA2B4 U KA2B3 UP 8.5/8 208-230 8.5/8 90/ 70 KA52B5 U KA52B3 UP 8/7 180/150 180/150 KA47D5 U KA47D3 UP 8/7 90/170 90/ 70 KA48D5 U KA48D3 UP 90/ 70 ● *The symbols in the standards column denote that they are registered in the following standards files, U: UL E48889 ● *Products conforming to the specifications of the Electrical Appliance and Material Safety Law (Japan) can be used in case the products are assembled in electric appliances used in Japan. (Products marked with the (PS)E mark) ■ General specification Materials Used KA47D3 Max. airflow: 1.9 m3/min (50 Hz) 2.2 m3/min (60 Hz) Max. static pressure: 53 Pa (50 Hz) 56 Pa (60 Hz) Mass: 360 g CU2B3 CU2B5 Common Elec. Spec. See page G-12. KA48D5 Usage Range KA52B3 Operating Temp. Range -20 ℃ ∼ +60 ℃ KA52B5 Standard Carton 20 to a carton of (450 x 380 x 150) mm, mass 10 kg CU47F3 CU47F5 1.92/ 2.26 1.2/ 1.4 68/ 80 42/ 49 CU48F5 ■ Standard airflow and static pressure characteristics (At rated voltage) KA□□D□ 40/ 45 CU52B5 19/ 24 0.23/ 0.26 0.07/ 0.10 40/ 45 27/ 34 2550/ 220/230 3000 100-120 1500/ 100-120 50/ 1900 200-240 60 200-240 14/13 90/ 70 100/ 80 CU50B5 14/11 170/130 170/130 CU47F5 14/10.5 170/130 170/130 CUJ47F5 14/11 80/ 60 80/ 60 CU48F5 14/10.5 80/ 60 80/ 60 UCP UCP V: VDE 3019UG appliances used in Japan. (Products marked with the (PS)E mark) ■ General specification Materials Used Venturi: Aluminum alloy die casting Propeller: Glass fiber reinforced polycarbonate resin Bearing: Double - sided shielded ball bearing Motor Shaded pole induction motor Protection type: Impedance protection CU55B3 Common Elec. Spec. See page G-12. CU55B5 Usage Range KAJ55B4 CU60B3 ℃ ∼ +55 ℃ in standard Operating Temp. Range -20 ℃ ∼ +60 ℃( -20 -20 ℃ ∼ +40 ℃ in VDE standard KAJ60B5 CU60B5 Standard Carton 30 to a carton of (450 x 380 x 160) mm, mass 12 kg CUJ47F5 ■ Standard airflow and static pressure characteristics (At rated voltage) Rated voltage ±10 % CU□□B□ ) Centrifugal Centrifugal CUJ55B5 UTV UCT CU47F3 P UCT CU48F3 ● *Products conforming to the specifications of the Electrical Appliance and Material Safety Law (Japan) can be used in case the products are assembled in electric KA60B5 KA60B3 UCP ● *The symbols in the standards column denote that they are registered in the following standards files, U: UL E48889, C: CSA LR49399, LR108118, T: TUV R60229-60302, CU50B5 CU52B3 58/ 65 UCP UCP ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. CU48F3 Rated voltage ±10 % 0.21/ 0.23 Std* UCP Axial KA48D3 53/ 56 100 100 200 200 2550/ 200 3000 50/ 115 60 208-230 208-230 115 Model Code Current Lock mA Current mA Lead Wire Type Std* Terminal Type 16/14.5 190/140 200/170 CU55B5 UC CU55B3 12/11 190/140 200/170 CUJ55B5 P 14/13 90/70 100/ 90 CU60B5 UC 14/12 90/70 100/ 90 CUJ60B5 P CU60B3 13/11 90/70 100/ 90 11/10 160/130 180/160 CU2B5 UC CU2B3 14/13 90/70 95/ 80 CU52B5 UC CU52B3 13/11 90/70 95/ 80 11/9 140/110 150/120 CU115B5 UTV Input W DC fans Axial DC fans KA47D5 67/ 78 Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min □120×25 (□4.7"×1.0") CU115B5 Shaded pole induction motor Protection type: Impedance protection KA□□B□ 1.9/ 2.2 Fan model code Venturi: Aluminum alloy die casting Propeller: PBT resin Bearing: Double - sided shielded ball bearing Motor KA55B4 UP ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. KA2B4 KA55B3 KA55B3 8.5/8 115 2250/ 100-120 50/ 2650 200-240 60 U Max. Airflow Silent Silent Fan model code 0.8/ 0.9 39/ 46 Input W Fans & Blowers Fans & Blowers KA series □ 92 × 38 mm AC Axial Fans & Blowers CU□□F□ CUJ60B5 ● Lead wire type (KA□□□4/KA□□□5) Silent Silent ■ External dimensions in mm (inches) ● Terminal type (KA□□□3) ■ External dimensions in mm (inches) ● Lead wire type (CU□□□5) ● Terminal type [2 terminals: with grounding tap](CU□□□3) Options (sold separately) ・Guard: F92UL guard ・Filter: F92 filter ・Power code: T2P1 code, D2P1 code, UL2P1 code Lead wire specification CUJ series: Heat resistant PVC 0.75 mm2 (30 conductors, 0.18 dia.) CU series: AWG22 UL1015 ■ Mounting hole dimensions in mm (inches) [Recommendation] Options (sold separately) ・Guard: F120UL guard ・Filter: F120 filter ・Power code: T2P1 code, D2P1 code, UL2P1 code Option Option G-64 Centrifugal Centrifugal ■ Mounting hole dimensions in mm (inches) [Recommendation] Axial AC fans Axial AC fans Lead wire specification KAJ series: Heat resistant PVC 0.75 mm2 (30 conductors, 0.18 dia.) KA series: AWG22 UL1015 G-65 100 14/12 200/180 300/270 CN55B5 100 15/13 200/180 300/270 CNJ55B5 200 14/12 110/ 90 155/135 CN60B5 0.33/ 0.35 83/ 88 2800/ 3200 44/ 48 200 15/13 110/ 90 155/135 CNJ60B5 16/13 200/170 300/260 CN2B5 115 Max. airflow: 2.6 m3/min (50 Hz) 3.0 m3/min (60 Hz) Max. static pressure: 83 Pa (50 Hz) 88 Pa (60 Hz) Mass: 500 g 2.4/ 2.8 1.6/ 1.6 85/ 99 0.30/ 0.34 74/ 84 56/ 56 0.09/ 0.10 23/ 24 43/ 47 UC CN2B3,CN2B2 UCP 110/ 90 160/140 CN52B5 115 2700/ 3150 220/230 11/10 150/130 210/180 CN115B5 UCT 13/13 100/ 90 130/120 CN50B5 UCT 100-120 9/8.5 110/100 110/100 CN47D5 UCT CN47D3,CN47D2 UCP 8.5/8 110/100 110/100 CNJ47D5 UC CN52B3,CN52B2 UCP CN48B3 UP P UCT CN48D3,CN48D2 UCP Note 60/50 60/50 CN48D5 9/8.5 60/50 60/50 CNJ48D5 CN2B3 CN2B5 CN47D2 CN48D2 MA2B3 MA47B3 32/28 400/310 620/600 MA55B3 UCP 115 29/28 270/250 470/460 MA2B3 UCP 200 32/28 200/150 300/300 MA60B3 0.61/ 0.75 50/ 55 UCP 33/30 150/130 250/240 MA77B3 UCP 100-120 33/32 300/270 440/430 MA47B3 UCP 200-240 33/32 150/140 240/240 MA48B3 UCP 2850/ 50/ 3400 220-240/ 60 208-230 MA55B3 ● *The symbols in the standards column denote that they are registered in the following standards files, U: UL E48889, C: CSA LR49399 ● *Products conforming to the specifications of the Electrical Appliance and Material Safety Law (Japan) can be used in case the products are assembled in electric appliances used in Japan. (Products marked with the (PS)E mark) ■ General specification Material used Venturi: Aluminum alloy die casting Propeller: ABS and PBT synthetic resins Capacitor cover: Glass fiber reinforced polycarbonate resin Capacitor: MF capacitor Bearing: Double - sided shielded ball bearing Motor Capacitor phase advancing type induction motor Protection type: Thermal protection Common Elec. Spec. See page G-12. Usage Range Rated voltage ±10 % Operating Temp. Range -20 ℃ ∼ +60 ℃ Standard Carton 12 to a carton of (380 x 370 x 190) mm, mass 12.0 kg Common Elec. Spec. See page G-12. ■ Standard airflow and static pressure characteristics (At rated voltage) CN50B5 Usage Range MA□B3 CN52B2 Operating Temp. Range -20 ℃ ∼ +60 ℃ (-20 ℃ ∼ +55 ℃ in Rated voltage ±10 % (Pa) 200 standard) (Pa) 80 CN60B3 60 CNJ47D5 20 CNJ48D5 0 50 Hz CNJ55B5 1 2 Airflow (m3/mi n) ● Lead wire type (CN□□□5) □104.8±0.3 (4.126 sq.±0.012) Airflow Lead wire specification CNJ series: Heat resistant PVC 0.75 mm2 (30 conductors, 0.18 dia.) CN series: AWG22 UL1015 Rotation 5 6 7 ■ External dimensions in mm (inches) 38.5±0.5 (1.5±0.02) 5.4 8 9 4 (0.16) Grounding tap 8-φ 4.5±0.3 (8-0.18 dia.) Airflow ■ Mounting hole dimensions in mm (inches) [Recommendation] ● Terminal type φ 172 (6.77 dia.) 8-φ 4.5±0.3 (8-0.18 dia.) 51±0.5 (2±0.02) 7 (0.27) R φ 16 6 di ) (φ 0) φ 162 16 (6.37 8 dia.) 2-φ 4.5 (2-0.18 dia.) 2-R5 2-φ 4.5 (2-0.18 dia.) 111° 111° □116 (4.61 sq.) 150 (5.91) □104.8 (4.126 sq.) Rotation Airflow (2 point mounting) (3 point mounting) .) 8 φ 12 (5 dia 4 -φ 4.5 (8-0.18 dia.) Option Option Options (sold separately) ・Guard: F120UL guard ・Filter: F120 filter ・Power code: T2P1 code, D2P1 code, UL2P1 code (for 2 terminals) D3P1 code, UL3P1 code (for 3 terminals) 54 . (6 R5 (Note) There is no grounding tap for CN series terminal type. ■ Mounting hole dimensions in mm (inches) [Recommendation] 146 (5.75) a. Name plate .2 ±0 81 146 (5.75) 6 (0.24) Options (sold separately) ・Guard: GUARD 172 ・Power code: T2P1 code, D2P1 code, UL2P1 code Identical for the intake and outlet sides G-66 Options G-72, 73, 74 Centrifugal Centrifugal Rotation 8-φ 4.5±0.3 (8-0.18 dia.) 2 3 4 Airflow (m3/mi n) 1.5 Terminal: 0.5 (T) x 3 (W) x 7 (L) (1 1. 2) 0.5 1 Airflow (m3/mi n) 1 Options Axial 30 1. 0±3 8± 0 50 Hz □119 (4.69 sq.) 4 (0.16) Grounding tap M4 through hole 4 (0.16) 50 Hz 0 AC fans Axial AC fans □104.8±0.3 (4.126 sq.±0.012) 10 5 80 40 ● Terminal type [2 terminals: without grounding tap] (CN□□□2) [3 terminals: with grounding tap] (CN□□□3) 38.5±0.5 (1.5±0.02) □119 (4.69 sq.) 15 0 3 ■ External dimensions in mm (inches) CNJ60B5 60 Hz 60 Hz 120 Silent Silent CN60B5 20 60 Hz 40 25 Static pressure CN60B2 CN□□D□ 85.4 (3.36) CN55B5 Static pressure CN55B3 100 162±0.3 (6.378 dia. ±0.012) CN□□B□ 160 (Pa) . ■ Standard airflow and static pressure characteristics (At rated voltage) 162 (6.378 dia.) Standard Carton 20 to a carton of (450 x 380 x 160) mm, mass 11 kg CN52B5 Static pressure CN52B3 Centrifugal Centrifugal CN48D5 CN55B2 Std* ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. MA48B3 MA77B3 Shaded pole induction motor Protection type: Impedance protection Motor CN48D3 100 Terminal Type Axial CN48B3 5.5 m3/min (50 Hz) 6.5 m3/min (60 Hz) Max. static pressure: 152 Pa (50 Hz) 186 Pa (60 Hz) Mass: 950 g MA60B3 Venturi: Aluminum alloy die casting Propeller: Glass fiber reinforced polycarbonate resin Bearing: Double - sided shielded ball bearing Materials Used Current Lock mA Current mA DC fans Axial DC fans CN47D5 152/ 186 Fan model code P ■ General specification CN47D3 194/ 229 Model Code Input W Silent Silent 9/8.5 φ172×150×51 (φ6.8"×6.0"×2.0) Max. airflow: ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● *The symbols in the standards column denote that they are registered in the following standards files, U: UL E48889, C: CSA LR49399, LR108118 T: TUV R60229-60302 ● *Products conforming to the specifications of the Electrical Appliance and Material Safety Law (Japan) can be used in case the products are assembled in electric appliances used in Japan. (Products marked with the (PS)E mark) (Note) Since CN60B2, CN52B2, and CN48D2 do not have a ground terminal, they are not products conforming to the specifications of the Electrical Appliance and Material Safety Law (Japan) CN2B2 Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min Note (※): _2: 2 terminals _3: 3 terminals CN115B5 5.5/ 6.5 P 120/100 140/120 200-240 Max. Airflow P 18/15 Fan model code m3/min CFM UC CN60B3,CN60B2 UCP Note 14/13 1700/ 100-120 50/ 1800 200-240 60 33/ 35 MAXI II UC CN55B3,CN55B2 UCP 200-240 208-230 □120×38 (□4.7"×1.5") 50/ 60 ■ Standard specification (6 92/ 106 AC Axial Fan 5 ide 4 d : φ ia. 16 ) 0) m3/min CFM 2.6/ 3.0 Model Code Current Lock mA Current mA Lead Wire Type Std* Terminal Type (*) Std* 6 CENTAUR III Input W Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min Fans & Blowers Fans & Blowers Max. Airflow es ■ Standard specification φ172 × 150 × 51 mm tak AC Axial Fan MA series φ1 6 CN series □ 120 × 38 mm AC Axial Fans & Blowers (In AC Axial Fans & Blowers G-72, 73, 74 G-67 ■ Standard specification 5.5/ 6.5 φ172×51 (φ6.8"×2.0") Max. airflow: 5.5 m3/min (50 Hz) 6.5 m3/min (60 Hz) Max. static pressure: 152 Pa (50 Hz) 186 Pa (60 Hz) Mass: 950 g 194/ 229 152/ 186 400/310 620/600 PA55B3 UCP 115 29/28 270/250 470/460 PA2B3 UCP 200 32/28 200/150 300/300 PA60B3 UCP 2850/ 220-240/ 50/ 3400 208-230 60 150/130 250/240 PA77B3 UCP 100-120 33/32 300/270 440/430 PA47B3 UCP 200-240 33/32 150/140 240/240 PA48B3 UCP 33/30 m3/min CFM 17/19 180/200 PA55H3 ■ General specification 6.8/ 7.4 134/ 139 0.54/ 0.56 61/ 64 200 2650/ 2900 115 50/ 60 38/48 208-230 ■ Wiring connection diagram AS2B61S Usage Range AS52B61 Operating Temp. Range - 20 ℃ ∼ + 60 ℃ AS52B61S Standard Carton 10 to a carton of (470 x 405 x 250 ) mm, mass 14.5 kg AS55B61 AS55B61S ■ Standard airflow and static pressure characteristics (At rated voltage) AS60B61 AS□B61 Yellow Thermal protector ■ Capacitor (Normally included) (Pa) 200 2 3 4 Terminal: 0.5 (T) x 3 (W) x 7 (L) 7 5 ide 4 di : φ a.) 16 0) 2 (6.3 78) (4 point mounting) 2-φ 4.5 (2-0.18 dia.) B AC axial fan with sensor 300±30 (11.8±1.2) 100 (3.94) Mating model code 300±30 (11.8±1.2) 40 (1.57) Sensor box 58 (2.28) 111° (3 point mounting) Sensor lead wire Power lead line 8-φ 5.5±0.3 (8-0.22 dia.) □138.5±0.5 (5.453 sq.±0.02) Model Code Standard* AS55B61S AS60B61S AS2B61S AS52B61S U U U U Sensor connection diagram 4 (0.16) 4 (0.16) □160 (6.30 sq.) 62 (2.44) Rotation Airflow Yellow White Option Airflow Rated Voltage V(±10 %) 100 200 115 208-230 Sensor circuit Option G-72, 73, 74 Lead wire specification: AWG20 UL1430 25 (0.98) 85.4 (3.36) 4-R5 Options (sold separately) ・Guard: GUARD 172 ・Power code: T2P1 code, D2P1 code, UL2P1 code Options R5 4-φ 4.5 (4-0.18 dia.) Identical for the intake and outlet sides Centrifugal Centrifugal 162±0.3 (6.378±0.012) 6 (0.24) Rotation G-68 E 6. φ 16 6( 162 (6.378) 11.5 (0.45) 6.5 0) 16 (φ 6( 4-φ 5.5 (4-0.22 dia.) Airflow 8-φ 5.5±0.3 (8-0.22 dia.) Rotation es 6 (0.24) 34 16 .) Axial φ ia 4d ° R81±0.15 □138.5 (5.453 sq.) 8 17 ) φ sq. 01 (7. 51 (2) 111 □156 (6.14 sq.) 4 (0.16) 162 (6.378) 7 (0.27) 12-φ 4.5±0.3 (12-0.18 dia.) φ 172 (6.77 dia.) 6.4 Static pressure 6 4 (0.16) AC fans Axial AC fans 19 ■ Mounting hole dimensions in mm (inches) [Recommendation] ■ Mounting hole dimensions in mm (inches) [Recommendation] mm (inches) Grounding tap M4 through hole 5 Airflow (m3/mi n) ■ External dimensions in ● Terminal type 1 ) 0 10 62 (2.44) □160 (6.30 sq.) □138.5±0.5 (5.453 sq.±0.02) Grounding tap M4 through hole 60 Hz 1. 2 20 7 4 6 8 Airflow (m3/mi n) (1 300 1. ± 8± 30 6 2 External Dimensions in mm A B C D E 31 23.5 24.5 14.5 4 37 28 23.5 13.5 3.5 Mating Capacity Model Code μF AS55B61,AS2B61 3.0 AS60B61,AS52B61 0.75 50 Hz ● Lead wire type 16 Static pressure Static pressure 5 A View from P ■ External dimensions in mm (inches) tak 4 80 50 Hz φ 3 60 Hz 0 40 Airflow (m3/mi n) 120 (In 2 0.5 Silent 1 P Centrifugal Silent 0 φ4.3 4.75 40 80 50 Hz Capacitor Red Rated voltage ±10 % 160 60 Blue Axial Centrifugal 40 U Common Elec. Spec. See page G-12. (Pa) 100 80 U 230/260 320/320 AS52B61 AS2B61 PA□H3 120 U 380/470 550/555 AS2B61 Capacitor phase advancing type induction motor Protection type: Thermal protection ■ Standard airflow and static pressure characteristics (At rated voltage) 60 Hz U 260/270 330/320 AS60B61 Venturi: Aluminum alloy die casting, Black baking paint Propeller: Glass fiber reinforced polycarbonate resin Capacitor: MF capacitor Bearing: Double - sided shielded ball bearing Material Used Standard Carton 12 to a carton of (420 x 410 x 220) mm, mass 12.5 kg 160 Standard* 380/470 570/620 AS55B61 ■ General specification Operating Temp. Range - 20 ℃ ∼ + 60 ℃ (Pa) 200 Lead wire type ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● *The symbols in the standards column denote that they are registered in the following standards files, U: UL E48889 AS60B61S PA□B3 Model Code Current Lock mA Current mA DC fans Axial DC fans Rated voltage ±10 % Input W Silent Silent Common Elec. Spec. See page G-12. Usage Range 240/ 261 Motor Capacitor phase advancing type induction motor Protection type: Thermal protection Motor Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min Fan model code Venturi: Aluminum alloy die casting Propeller: ABS and PBT synthetic resins Capacitor cover: Glass fiber reinforced polycarbonate resin Capacitor: MF capacitor Bearing: Double - sided shielded ball bearing PA55B3 Max. Airflow 100 Max. airflow: 6.8 m3/min (50 Hz) 7.4 m3/min (60 Hz) Max. static pressure: 134 Pa (50 Hz) 139 Pa (60 Hz) Mass: 1300 g Material Used PA77B3 ASTEROID UP 100 4.7/4.7 166/166 90/75 0.36/0.30 44/44 2500/2500 PA48B3 PA60B3 32/28 Standard* ■ Standard specification ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● *The symbols in the standards column denote that they are registered in the following standards files, U: UL E48889, C: CSA LR49399 ● *Products conforming to the specifications of the Electrical Appliance and Material Safety Law (Japan) can be used in case the products are assembled in electric appliances used in Japan. (Products marked with the (PS)E mark) PA2B3 PA55H3 46/ 50 100 Terminal Type AC Axial Fan □160×62 (□6.3"×2.4") Fan model code PA47B3 0.61/ 0.75 Current Lock mA Current mA D m3/min CFM Model Code Input W Fans & Blowers Fans & Blowers PARKY II Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min Max. Airflow AS Series □ 160 × 62 mm C AC Axial Fan φ172 × 51 mm 10 PA Series AC Axial Fans & Blowers 4.5 AC Axial Fans & Blowers Output 0V Lead wire specification (senor side): AWG 22 UL1007 Sensor Spec. G-15 G-69 200 381/ 431 176/ 216 0.71/ 0.87 115 2750/ 3050 208-230 59/ 61 60/75 3φ 200 / 50/ 200-208 60 Aluminum alloy die casting, Black baking paint Venturi: Propeller: Polycarbonate resin Bearing: Ball bearing Connector box: Polycarbonate Material Used 1 3-phase 1 PL55B31,PL2B31 (Pa) 250 20 50 Hz 50 48 0 0.5 4 8 19 29 AMP 187 Tab 21.5 4.5 48 ■ Mounting hole dimensions in mm (inches) [Recommendation] □178 (7.01 sq.) Common Elec. Spec. See page G-12. Usage Range CB55B3-Y Operating Temp. Range - 20 ℃ ∼ + 60 ℃ CB55B4-Y ■ Standard airflow and static pressure characteristics (At rated voltage) 50 Hz 0 0.2 0.4 0.6 0.8 Airflow (m3/mi n) 1.0 ■ External dimensions in mm (inches) ● Lead wire type (CB□□4) 9 (0.35) 125 (4.92) 50.4 (1.98) φ 62 (2.44) 60 φ 10 (0.39) 70 PL55B31S PL60B31S PL2B31S PL52B31S PL74B31S □152.7±0.5 (6.012 sq. ±0.02) 6 (0.24) Options G-72, 73, 74 90 (3.54) 6 (0.24) Options (sold separately) ・Guard: F180UL guard ・Power code: PL4P1 code ・Sensor code: PL sensor 1 code Standard* ● Terminal type (CB□□3) 125 (4.92) 3-φ 4.5 (3-.018 dia.) UCT 50.4 (1.98) φ 60 10 (0.39) 62 (2.44) φ 70 (2 67 .6 4) 104.8±0.3 (4.126±0.012) 31 (1.22) 64 (2.52) Model Code 8 (0.31) Lead wire specification 300±30 (11.8±1.2) 126 (4.96) 63 (2.48) 28 (1.10) 40 (1.57) Rated Voltage V (±10 %) 100 200 115 208-230 3-phase 200/200-208 104.8±0.3 (4.126±0.012) 8 (0.31) 31 (1.22) 28 (1.10) T: 0.5 W: 4.75 L: 6.4 6.2 (0.24) 18.5 (0.73) Options (sold separately) ・Power code: T2P1 code, D2P1 code, UL2P1 code Options G-72, 73, 74 G-71 Option Option G-15 50 Lead wire specification: AWG22 UL1015 Mating model code 4P connector for power feeding Connector HG: AMP 1-480703-0 Connector pin: AMP 350706-1 or 350705-1 □180 (7.09 sq.) Sensor Spec. 60 Hz 100 104.8±0.3 (4.126±0.012) 63(2.48) Identical for the intake and outlet sides T: TUV FILE No.9051212 G-70 150 Centrifugal Centrifugal Alarm output 3P connector Connector HG: AMP 1-480701-0 Connector pin: AMP 100 (3.94) 350706-7 8-intake side φ6±0.5 8-inner side φ 5.5±0.5 (8-0.22 dia.) Rated voltage ±10 % CB□□B□ 104.8±0.3 (4.126±0.012) 63 (2.48) AC axial fan with sensor UCP Axial 90 (3.54) CB52B3 CB52B4 3-φ 4.5 (3-0.18 dia.) □152.7 (6.012 sq.) 6 (0.24) UCP UC 17.5/16.5 180/145 230/200 CB52B4 AC fans Axial AC fans □180 (7.09 sq.) 6 (0.24) CB2B3 CB52B3 4 -φ 5.5 (4-0.22 dia.) □152.7 ±0.5 (6.012 sq.±0.02) UC Shaded pole induction motor Protection type: Impedance protection 0 19 .) φ dia 48 (7. 8-intake side φ6±0.5 8-inner side φ5.5±0.5 (8-0.22 dia.) 280/245 380/330 CB2B4 Motor 31.5 28 (1.10) 100 (3.94) UCP 17/16 Silent Silent 4P connector for power feeding Connector HG: AMP 1-480703-0 Connector pin: AMP 350706-1 or 350705-1 63 (2.48) 40 (1.57) CB60B3 Material Used 4.5 n) Airflow (m3/mi ● Terminal type UCP UC Housing: Aluminum alloy die casting Impeller: Polycarbonate resin Bearing: Double - sided shielded ball bearing Inlet cover: Aluminum board or Galvanized steel sheet Terminal: Brass, tin plating 12 ■ External dimensions in mm (inches) CB55B3-Y 150/140 200/170 CB60B4 (Pa) 200 Capacity 2 μF 0.5 115 UC 15/15 ■ General specification 3.7 100 10±3 2-φ 2.7 ±0.2 29 Static pressure 150 88 Pa (50 Hz) 127 Pa (60 Hz) CB60B4 φ 4.3 60 Hz 50/ 60 Centrifugal Centrifugal PL74B31S 20 φ 4.3 +0.3 - 0.2 18.5/17 220/210 300/260 CB55B4-Y 200 2600/ 2850 ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● *The symbols in the standards column denote that they are registered in the following standards files, U: UL E48889, C: CSA LR49399, LR: LR108118 ● *Products conforming to the specifications of the Electrical Appliance and Material Safety Law (Japan) can be used in case the products are assembled in electric appliances used in Japan. (Products marked with the (PS)E mark) PL60B31,PL52B31 Capacity 8 μF 200 0.65 m3/min (50 Hz) 0.7 m3/min (60 Hz) Max. static pressure: CB60B3 ■ Capacitor (Normally included) 53/ 55 Model Code Current Lock mA Current mA Lead Wire Type Standard* Terminal Type Standard* Axial PL60B31 PL □□ B31 PL74B31 W 0.35/ 0.51 Input W DC fans Axial DC fans PL55B31S PL60B31S V 3 ■ Standard airflow and static pressure characteristics (At rated voltage) PL60B31-EX 2 Motor Standard Carton 5 to a carton of (470 x 435 x 215) mm, mass 12 kg Max. airflow: CB2B3 U Operating Temp. Range - 20 ℃ ∼ + 60 ℃ □125×41 (□4.9"×1.6") CB2B4 Rated voltage ±10 % Usage Range 88/ 127 Fan model code 3 Common Elec. Spec. See page G-12. 23/ 25 208-230 Mass: 570 g Capacitor 2 Motor PL52B31S PL55B31-EX Single phase Capacitor phase advancing type induction motor and 3-phase induction motor Protection type: Thermal protection Motor External and internal capacitor types available Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min 100 0.65/ 0.70 UC ■ Wiring connection diagram ■ General specification PL52B31-EX PL55B31 210/220 560/540 PL74B31 10±3 PL52B31 PL52B31-EX 35 PL2B31S 310/390 520/530 PL52B31 Max. Airflow Silent Silent PL2B31-EX PL2B31-EX ● Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification. ● *The symbols in the standards column denote that they are registered in the following standards files, U: UL E48889, C: CSA LR49399 Fan model code PL2B31 330/390 560/580 PL2B31 m3/min CFM 70 (2.76) 10.8 m /min (50 Hz) 12.2 m3/min (60 Hz) Max. static pressure: 176 Pa (50 Hz) 216 Pa (60 Hz) Mass: 2200 g PL60B31-EX 4 Max. airflow: 3 PL55B31-EX 560/680 1000/1000 PL60B31 CB BLOWER 79.5±0.3 (3.130±0.012) □180×90 (□7.1"×3.5") 60/75 650/780 1160/1160 PL55B31 ■ Standard specification (0 8 .3 1) 10.8/ 12.2 50/ 60 AC Centrifugal Blower 64 (2.52) 100 Model Code Current Lock mA Current mA Terminal Type Standard* Internal Capacitor Type 126 (4.96) m3/min CFM Input W Fans & Blowers Fans & Blowers PLANET Max. Static Pressure Noise Speed Rated Vol. Freq. −1 V (±10 %) Hz Pa inH2O dB min Max. Airflow 9 (0.35) ■ Standard specification 125 × 126 × 41 mm 9 (0.35) AC Axial Fan CB Series 79.5±0.3 (3.130±0.012) 70 (2.76) PL Series □ 180 × 90 mm AC Axial Fans & Blowers Static pressure AC Axial Fans & Blowers Guards (Options) F60UL Guard (Mass 12 g) φ 89.4 Material: Mild steel wire 1.6 dia. Surface treatment: Nickel chromium plating Material: Mild steel wire 1.6 dia. Surface treatment: Nickel chromium plating GUARD 172 F180UL Guard (9) 2-φ 4.8±0.8 4-R3±0.4 (Inner dimension) 6 ○ ○ ○ ○ ○ Filter VE WE KA CU CN F80 F92 F120 ○ ○ ○ ○ ○ ○ ○ Component (Model Code) F80 Filter 6 ○ ○ ○ 7 H T M/C D 83.6 10 71.5 φ 3.8 F92 Filter 96.5 10 82.5 φ 3.8 F120 Filter 123.7 10.7 104.8 φ 4.6 ■ Flange spacer 161 φ 148.6 φ 11.2 15 2. 7± 0. (φ 17) F80 F92 F120 Silent Silent 5.9±0.5 SKUD SKLD SCUDM SCNDM KUDC PUDC KLDC CUDC CNDH D1238 4-D (T) 4-φ 4.6 ±0.5 □113.3±0.5 Note: Two retainer pins are provided on the F80 filter. T F127UL Guard □104.8±0.5 4-φ 4.5±0.5 H 4-φ 4.5±0.5 Material: Mild steel wire 1.6 dia. Surface treatment: Nickel chromium plating 5±0.5 5±0.5 (H) M/C 50 φ 58 φ 10 φ 32 Retainer (PPO resin UL94V-0) 4-φ 4.5±0.3 F120UL Guard (Mass 29 g) Media (Polyurethane foam) Axial fan φ 76.2 Material: Polycarbonate (black) UL94V-2 Filter Guard (PPO resin UL94V-0) Fans & Blowers 52 φ φ 38 3-piece set (φ 17) (φ 17) AC Axial Fans □50 □71.5 4 4-φ 4.6±0.2 DC Axial Fans Fans & Blowers (3.6) 2.5 List of mating fan series ■ Filter F92UL Guard (Mass 16 g) □82.5 5 □59 F80UL Guard (Mass 14 g) (H) F60P Guard (Mass 4 g) Filters and Other Accessories (Options) Accessories (T) Accessories D φ 30 A B φ 45 E 5±0.5 φ 176 4-φ 4.5±0.5 Axial DC fans Axial DC fans φ 115.6 C Material: Mild steel wire 2 dia. Surface treatment: Nickel chromium plating φ 126 φ 138 43.5 30.5 Material: Mild steel wire 1.6 dia. Surface treatment: Nickel chromium plating ・Guard special for intake side of SCUD (metal venturi) fans. ・Guard special for intake side of SCND (metal venturi) fans. G-72 3.5 15 19.8 CUDC 11 3.5 28 19.8 CNDC (Installing a flange spacer) ※Ribbed venturis (PUDC-R, CUDC-R) are available for PUDC and CUDC. ○*2 ■ Inlet ring ○ ○ ○ 21±1 118 ○ ○ 45゚ (0.8) ○ 24 (R 22 ) ○ ○ 4×φ 4.3±0.5 ○*2 ○*1 ○*1 ○ ○ ○ 5± 0. 8 ○ ○ ○*2 ○ ○ ○ ○ ○ ○ ○ 6×φ 5.5±0.5 Through hole 6× 60 ° Material: Galvanized steel sheet ○ ○ ○ ○ Component (Model Code) Mating Model Code E2271 Inlet ring E2271Z ○ *1: Can be installed only on outlet side. *2: Can be installed only on intake side. All guards conform to the UL standard when combined with Japan Servo fans. The installation of a filter, guard and other accessories will constitute a ventilating load, reducing the airflow.Select a suitable guard, taking into consideration the increase in air resistance. (See Figs. 12 and 13 on page G-7.) Option Option Material: Mild steel wire 1.6 dia. Surface treatment: Nickel chromium plating 11 8 Flange Spacer CNDC Centrifugal Centrifugal φ 138 φ 29 Flange Spacer CUDC(※) 8 Insert a flange spacer into the ribs of a venturi. Axial φ 126 DC Axial Fans SCN Guard (Mass 55 g) KUDC,PUDC AC fans Axial AC fans SCU Guard (Mass 50 g) 17 14.5 4×90゚ 4.7 Material: Mild steel wire 1.6 dia. Surface treatment: Nickel chromium plating 2 φ - 1 .5 ○*2 ○*1 ○*1 8 φ 242±0.8 (182.3) +0.4 4.3 -0.2 (Inner dimension) 17 5 +2 φ φ (Mo 188. 4 unt ing φ pitc 19 h) 5. 8 +1 F60 F80 F92 F120 F127 GUARD F180 F200 SCN SCU UL UL UL UL UL 172 UL UL Flange Spacer PUDC(※) 5 Silent Silent 1.5 AC Axial Fans +2 19 SCU SCN VE WE KA CU CN MA PA PL SKUD SKLD SCUD SCND SCUDM SCNDM TUDC PUDC KUDC KLDC CUDC CNDC D1238 D1338 MADC PADC G1751 SADC F60P A B C D E Mating Model Code mm mm mm mm mm Centrifugal Centrifugal Guard φ 29 Component (Model Code) List of mating fan series F200UL Guard (Mass 82 g) φ Material: Mild steel wire 1.6 dia. Surface treatment: Nickel chromium plating φ 252 Material: Mild steel wire 1.6 dia. Surface treatment: Nickel chromium plating φ 155±0.8 Material: Mild steel wire 1.6 dia. Surface treatment: Nickel chromium plating G-73 Plug Cords (Options) Accessories ■ Plug cords for AC fans D2P1 cord (Mass 35 g) UL2P1 cord (Mass 41 g) UL standard product (UL file No. E78112) Cord 0.16 dia. 41 conductors Black, heat resistant vinyl Certified under the Electrical Appliance and Material Safety Law (Japan) (<PS>E mark approved) Cord 0.18 dia. 30 conductors Black, heat resistant vinyl 24 27 1000±30 15 15 1000 7.5 10 8 20 For wiring inside equipment Cord 0.18 dia. 30 conductors Black, heat resistant vinyl 1000±30 11 10 T2P1 cord 13 15.5 8 19 8 Fans & Blowers (Common specification: Rated 3 A, voltage 250 V, dielectric strength 1 minute at 1500 V 50 Hz) 16 * UL2P2 cord with 2m length also available. D3P1 cord (Mass 59 g) UL3P1 cord (Mass 60 g) UL standard product (UL file No. E78112) Cord: For power feeding 0.16 dia. 41 conductors Black, heat resistant vinyl For grounding AWG18 green/yellow spiral, heat resistant vinyl 1000±30 24 15.5 11 30 Axial DC fans 5 ・UL3P2 cord with 2 m length also available. With Sensor (option) 1000±30 (6) Black AMP:1-480700-0 For grounding 10 8 27 8 PL sensor 1 cord Connector HG (Plug) 1000±30 15 For grounding 10 4.5 26 19 8 19.5 Silent Certified under the Electrical Appliance and Material Safety Law (Japan) (<PS>E mark approved) Cord: For power feeding 0.18 dia. 30 conductors Black, heat resistant vinyl For grounding 0.18 dia. 50 conductors Black, heat resistant vinyl White Open collector output Black 1 1 White 2 GND 3 Not used 3 Lead wire specification UL1007 AWG22 Wiring diagram Centrifugal PL4P1 cord 1000±30 Connector HG (Plug) PL 3 Phases (200 V) PL Single Phase (External capacitor) PL-EX Single Phase (Internal capacitor) (6) Yellow Red Black AMP:1-480702-0 Yellow Yellow U 1 2 3 4 1 4 Green/Yellow Green/ Yellow Lead wire specification Yellow, Red, Black:UL1430 AWG20 Green/Yelow: UL1015 AWG18 Red V Black W 3 phases 200 V Wiring diagram 1 2 3 4 Green/ Yellow Capacitor Red Black Wiring diagram Yellow Power source (Single phase) 1 2 3 4 Green/ Yellow Silent List of mating fan series Cord Axial AC fans AC Axial Fans WE KA CU CN(2 terminals) T2P1 D2P1 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ UL2P1 UL3P1 PL4P1 PL sensor ○ ○ ○ ○ ○ ○ CN(3 terminals) MA PA PL D3P1 ○ ○ ○ ○ ■ Plug cords for DC fans DCLD030PT-ZZ01 (P sensor output cord) Centrifugal 320±10 Fan connection connector 4321 Red (+V) Black (GND) Yellow (sensor) Lead wire UL3266 AWG24 ・Lead wire ends are sheathed to protect conductors. (Sheath peeling dimension10±5) Option Component (Model Code) DCLD030ST-ZZ01 DCLD030PT-ZZ01 G-74 Mating Model Code E1033H□□B□AM-04 320±10 Fan connection connector 4321 DCLD030ST-ZZ01 (S sensor output cord) Lead wire UL3266 AWG24 Red (+V) Black (GND) Yellow (sensor) Not used Red Black Wiring diagram Power source (Single phase)