026a/eng For future reference, please keep this manual in a safe place This manual should be read in conjunction with the current product catalogue. Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.These instructions indicate the level of potential hazard by label of “Caution”, “Warning” or “Danger”. To ensure safety, be sure to observe ISO4414 (Note1), JIS B 8370 (Note2) and other safety practices. Note 1: ISO 4414: Pneumatic fluid power – Recommendations for the application of equipment to transmission and control systems. Note 2: JIS B 8370: Pneumatic system axiom. CAUTION : Operator error could result in injury or equipment damage. WARNING: Operator error could result in serious injury or loss of life. DANGER : In extreme conditions, there is a possible result of serious injury or loss of life. WARNING 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. 2. Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. 3. Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 2) When equipment is to be removed, confirm the safety process as mentioned above. Switch off air and electrical supplies and exhaust all residual compressed air in the system. 3) Before machinery/equipment is re-started, ensure all safety measures to prevent sudden movement of cylinders etc. (Bleed air into the system gradually to create back-pressure, i.e. incorporate a soft-start valve). 4. Contact SMC if the product is to be used in any of the following conditions: 1) Conditions and environments beyond the given specifications, or if product is used outdoors. 2) Installations in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverage, recreation equipment, emergency stop circuits, press applications, or safety equipment. 3) An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. CAUTION Ensure that the air supply system is filtered to 5 micron. PFW (WATER) standard specifications PFW704/PFW720/PFW740 (self contained type). (Fig 1) Operation indicating lamp Response time Hysteresis Power voltage Current consumption Withstand voltage Insulation resistance Noise resistance Vibration resistance Shock resistance Weight Port size PFW720-k-k PFW740-k-k Water Karman vortex 0.6~4 L/min 2~16 L/min 5~40 L/min 0.05 L/min 0.1 L/min 0.5 L/min L/min, gal (US)/min L, gal (US) 0~1 MPa 1.5 MPa 0~999999L 0~50°C (w/o condensation) ±5% F.S. or less ±3% F.S. or less ±5% F.S. or less (0~50°C) 27: NPN open collector, 30V, 80mA, 2 outputs 67: PNP open collector, 80mA, 2 outputs OUT1: Green, OUT2: Red, as turning on the power 1 sec. Hysteresis mode: Variable (from 0) Wind comparator mode: Fixed, 3 digits DC12~24V (Ripple ±10% or less) 70mA or less AC1000V for 1 min. between all the external terminals and case 2 MΩ (DC500V) between all the external terminals and case 1000Vp-p, Pulse duration: 1 µs, Rise: 1 ns 10~500Hz, 2 hours each in X, Y, Z direction at smaller vibration of amplitude: 1.5mm and acceleration: 98m/s2 490m/s2, times each in X, Y, Z direction 460g (w/o lead wires) 520g (w/o lead wires) 700g (w/o lead wires) Rc3/8 Rc3/8, 1/2 Rc/1/2, 3/4 NPT3/8 NPT3/8, 1/2 NPT1/2, 3/4 G3/8 G3/8, 1/2 G1/2, 3/4 Model Fluid Detection type Measuring flow range Resolution Display unit Instantaneous flow Integrated flow Integrated flow range Operating temperature range Linearity (Note 1) Repeatability (Note 1) Temperature characteristic (Note 1) Output (Note 2) Operation indicating lamp Response time Hysteresis Power voltage Current consumption Weight PFW310-k PFW300-k PFW301-k PFW320-k PFW321-k Water Karman vortex 0.6~4 L/min 2~16 L/min 5~40 L/min 0.05 L/min 0.1 L/min 0.5 L/min L/min, gal (US)/min L, gal (US) 0~999999L 0~50°C (w/o condensation) ±5% F.S. or less ±3% F.S. or less ±5% F.S. or less (0~50°C) NPN open PNP open NPN open PNP open NPN open PNP open collector collector collector collector collector collector 30V 30V 30V 80mA 80mA 80mA 80mA 80mA 80mA 2 outputs 2 outputs 2 outputs 2 outputs 2 outputs 2 outputs OUT1: Green, OUT2: Red, as turning on the power 1 sec. Hysteresis mode: Variable (from 0) Wind comparator mode: Fixed, 3 digits DC12~24V (Ripple ±10% or less) 50mA or less 45g Installation. WARNING Ensure all air and power supplies are ISOLATED before commencing installation. Do not install these switches in explosive atmospheres. If these switches are exposed to water or oil droplets, ensure that the switches are protected. If it is intended to energise a switch for an extended period, please consult SMC. Load must not exceed the maximum stated load. If the applied voltage is lower than the specified voltage, the load may NOT operate. Check that the formula: Source voltage-switch internal voltage >load operating voltage. Input data will not be erased when POWER is switched OFF. (EEPROM storage) DO NOT ATTEMPT TO DISASSEMBLE OR MODIFY A SWITCH. Do not operate a switch outside of the specified flow and pressure range. When operating a water switch, control the valve closing speed utilising a water hammer control valve. Ensure when operating a switch, the measuring section is completely filled with liquid. Do not exceed specified flow range speeds. Do not subject a switch to shock loads exceeding 10G. The switch output remains in the OFF condition for 1 second after power is applied. Note: Lead wire colours have been changed as shown in the table below due to JIS Standard amendment. Power supply wire GND wire OUT 1, Analog output wire OUT 2 Old colour Red Black White Yellow New colour Brown Blue Black White Wire colour and terminal number (Fig 4) To prevent mis-wiring, ensure wire colours and terminal numbers conform to the wiring specification. Do not apply repeated bending or tensile stress to the wiring. Check wire insulation is not damaged. Keep control wires and power wires separated to prevent noise transmission. Surge Voltage To prevent switch damage, do not subject the switch to any form of surge voltage i.e. induction motor, induction furnace. Install surge voltage suppression. WARNING. When installing a switch follow the listed torque specifications shown in the table below. Thread 1/8 1/4 3/8 1/2 Tightening torque Nm 7 to 9 12 to 14 22 to 24 28 to 30 1 N•m=10.2 kgf/cm When handling a switch do not apply excessive force to the unit as damage will cause malfunction. When installing a switch ENSURE 80MM OF PIPE LENGTH IS LEFT EITHER SIDE OF THE SWITCH BODY. Check ambient and fluid temperatures are within the specifications 0~50°C. If the temperature drops below 5°C FREEZING MAY OCCUR. Installation of an air dryer is recommended. Calibration procedure (Fig 5) Model Measuring fluid Detection Measuring flow range Operating pressure range Proof pressure Operating temperature range Power voltage Current consumption Weight Port size PFW504-k PFW520-k Water Karman vortex 2~16 L/min 0~1 MPa 1.5 MPa 0~50°C (w/o condensation) DC12~24V (Ripple ±10% or less) 20mA or less 470g (w/o lead wires) Rc3/8, 1/2 NPT3/8, 1/2 G3/8, 1/2 0.6~4 L/min 410g (w/o lead wires) Rc3/8 NPT3/8 G3/8 PFW540-k 5~40 L/min Lock out mode Manual calibration 650g (w/o lead wires) Rc/1/2, 3/4 NPT1/2, 3/4 G1/2, 3/4 Operation of switch is not compromised if a button is pushed by mistake. Calibrate set point for switch output. Initial set up Calibrate display mode (instant flow, integrated flow), unit mode and output mode (standard, reversed). Remote Type Self-contained type Procedure Auto preset Calibrate set point automatically. Normal operation Manual calibration The data set by auto preset function can be fine tuned. Flow displayed and switch operation occurs. Fig 2 Fig 1 Construction (Fig 3) Fig 5 For water Switch controls description (Fig 6) Parts list No. 1 2 3 4 Description Attachment Packing Body Sensor Material SUS NBR PPS PPS Fig 3 "-67" PNP open collector "-27" NPN open collector Brown DC(+) 30V, 80mA Residual voltage: 1V or less LED (Green) LED (Red) Max.80mA Black OUT1 Load Max.80mA White OUT2 Black OUT1 Max.80mA Press the UP and DOWN buttons simultaneously to reset the switch. Display of integrating flow rate is "0". Displays instant/integrating flow and set point. " " blinks when calculating the integrating flow rating. OUT1 (Green) UP key Light turns on when OUT1 is ON. Light blinks on and off when over current error occurs. In creases on/off set point. OUT2 (Red) Load LED (Green) White OUT2 Max.80mA Load Load Blue DC(-) LED Fig 4 SET key Brown DC(+) 80mA 12 to 24 VDC RESET LED (Red) Blue DC(-) 12 to 24 VDC Light turns on when OUT2 is ON. Light blinks on and off when over current error occurs. Changes the set point and mode of operation. DOWN key Decreases on/off set point. CAUTION Calibration data is stored in an EEPROM rated to 20 years. Without POWER. CAUTION Wiring (Fig 4) Remote type PFW504/PFW520/PFW540 sensor specifications (Fig 2) PFW704-k-k Note 1:Output function (OUT1 and OUT2) is available only for instantaneous flow display, but not for integrated flow display. Note 2:Window comparator mode: The P1 and P2 setpoints have to set at least 7 digits apart. This is caused by hysteresis (3 digits) for P1 and P2 and the need for the setpoints to be at least 1 digit different (after including the hysteresis). 1 digit means Min setting unit (refer to the above). CAUTION PFW311-k Note 1:Total accuracy for the combination with PFW504/PFW520/PFW540. Note 2:Output function (OUT1 and OUT2) is available only for instantaneous flow display, but not for integrated flow display. Note 3:Window comparator mode: The P1 and P2 setpoints have to set at least 7 digits apart. This is caused by hysteresis (3 digits) for P1 and P2 and the need for the setpoints to be at least 1 digit different (after including the hysteresis). 1 digit means Min setting unit (refer to the above). Circuit Model Measuring fluid Detection Measuring flow range Resolution Display unit Instantaneous flow Integrated flow Operating pressure range Proof pressure Integrated flow range Operating temperature range Linearity Repeatability Temperature characteristic Output (Note 1) Remote type PFW31/PFW30/PFW32 display module specifications (Fig 2) Circuit Installation and Maintenance Manual PFW Series Digital Flow Switch (Water) Fig 6 Initial set-up (Fig 7) Auto pre-set (Fig 9) Error codes (Fig 11) Display The procedure is identical for both self-contained or remote units. 1 Calibration value input mode 1. Initial setup mode 2. Selection of display mode 3. Selection of display unit E E E E SET Press the "SET" button. Press the "SET" button for at least 1 second until the display " " changes to " " or " ". E SET Select display unit by pressing the button "G" and "H". 4. Selection of "OUT1 output mode" 5. Selection of "OUT2 output mode" Number of unit (Refer to Table 1 .) E E E SET Press the "SET" button. Select standard or reversed output mode by pressing the "G" button. : Standard output : reversed output (Refer to Table 2 .) Select standard or reversed output mode by pressing the "G" button. : Standard output : Reversed output E E Press the "SET" button. Select instant flow or integrated flow display by pressing the button "G". : Instant flow indication : Integrated flow indication 3. Preparation of auto preset 2. Auto preset mode E Press the "SET" button. Press the "SET" button until " " is displayed. Select " " by pressing the "G" button. 4. OUT1 auto preset 5. Preparation of auto preset E SET By pressing the "SET" button, the calibration is completed. E SET SET Press the "SET" button. Press the "SET" button and confirm that " " alternates with set point value. This will set the best values automatically. E ( ( OUT1 is prepared for setting by flowing the fluid. In case that OUT1 is not required to calibrate, press the "G" and "H" buttons simultaneously. 6. OUT2 auto preset E E OUT2 is prepared for setting by flowing the fluid. In case that OUT2 is not required to calibrate, press the "G" and "H" buttons simultaneously. ) Press the "SET" button and confirm that " " alternates with set point value. This will set the best values automatically. ON (C.C1) By pressing the "SET" button, the calibration is completed. Hysterisis 3 (digit) Instant flow l /min. GPM Integrated flow l gal (us) YES ON GPM=gal (US)/min. OFF • Hysteresis mode Flow direction R ON NO OFF Output mode Out1 *OUT2 is same as OUT1 Flow direction R YES ON OFF • Hysteresis mode Start of integration Lock out E H (Fixed hysteresis) =3digit ON NO OFF Lock out mode------------Prevent unauthorised operation. Press the "H" and the "SET" buttons simultaneously. " " blinks and the integration starts. Flow direction R Flow direction R • Window comparator mode E E Integration can be up to " ", but only the last three figures are displayed normally. Press the "H" button to confirm the first three figures. Press the "SET" button for more than three seconds until the display changes to " ", " ", " " and then " ". Stop of integration Lock out release Select " " by pressing the "G" button. E Fig 7 Instant flow can be confirmed by pressing the "G" button while integrating. Manual calibration (Fig 8) 1 Calibration value input mode (manual) 3. Input set point value for OUT1 (1) 2. Manual mode E E E SET E Press the "SET" button. Press the "SET" button referring to Table 2 . " " is for manual setting, so press the "SET" button one more time. " " or " " alternates with set point value. G button: Increase set point value. H button: Decrease set point value. 4. Input set point value for OUT1 (2) 5. Input set point value for OUT2 (1) 6. Input set point value for OUT2 (2) E SET E E Press the "SET" button. " " or " " alternates with set point value. G button: Increase set point value. H button: Decrease set point value. SET E Press the "SET" button. " " or " " alternates with set point value. G button: Increase set point value. H button: Decrease set point value. " " or " " alternates with set point value. G button: Increase set point value. H button: Decrease set point value. E Fig 10 SET E By pressing the "SET" button, the calibration is completed. Turn off the power and verify the load connected output 1. Output 1 (Black wire) could be shorted out. Verify that the output is not shorted out and then reset the switch. Output 2 output current is exceeding 80mA. Turn off the power and verify the load connected output 2. Output 2 (white wire) could be shorted out. Verify that the output is not shorted out and then reset the switch. Fig 11 Interlock circuit: If using switches in an interlock circuit ensure multiple switch functions are used and monitor the system on a regular basis. Integrating flow function H (Fixed hysteresis) =3digit • Window comparator mode Output 1 output current is exceeding 80mA. Ensure all air and power supplies are ISOLATED before carrying out any maintenance work. Ensure correct operation of a switch on a regular basis. Other functions (Fig 10) Output mode Table 2 Push the Up and Down buttons to reset all the data. CAUTION Fig 9 Press the "H" and the "SET" buttons simultaneously. Display stops the integration and keeps the integrated value at that time. To start the integration again, press the "H" and the "SET" buttons simultaneously. Display is cleared by pressing the "G" and the "H" buttons simultaneously for more than two seconds. Press the "SET" button for more than three seconds until the display changes to " ". Select " " by pressing the "G" button. E For additional information please contact your local SMC office, see details below. SET By pressing the "SET" button, the calibration is completed. E SET By pressing the "SET" button, the calibration is completed. Solution Calibration was changed by accident, reason unknown. Maintenance ON=C.C1 OFF=C-3digit, C1-3digit (1 digit is the min. setting unit.) For water Fig 8 SET OFF Table 1 No. 1 2 ) Cause When you enquire about the product, please contact the following SMC Corporation: ENGLAND Phone 01908-563888 TURKEY Phone 212-2211512 ITALY Phone 02-92711 GERMANY Phone 6103-402-0 HOLLAND Phone 020-5318888 FRANCE Phone 01-64-76-10-00 SWITZERLAND Phone 052-396 31 31 SWEDEN Phone 08-603 07 00 SPAIN Phone 945-184100 AUSTRIA Phone 02262-62-280 Phone 902-255255 IRELAND Phone 01-4501822 GREECE Phone 01-3426076 DENMARK Phone 70 25 29 00 FINLAND Phone 09-68 10 21 NORWAY Phone 67-12 90 20 BELGIUM Phone 03-3551464 POLAND Phone 48-22-6131847 PORTUGAL Phone 02-610 8922