Rittling Regency F-Series Enclosures Heating Cooling Fresh Air Clean Air Rittling... Custom-Building Innovative Hydronic Systems For Commerce, Industry and Institutions Since 1946 Rittling long ago coined the phrase “Reinventing Finned Tube” to describe its commitment to design innovation... and its unlimited custom engineering capability. For decades, Rittling’s constantly expanding inventory and proven ability to control costs without compromising the highest quality standards in manufacturing have made the name synonymous with image, performance, reliability, price, delivery and service. Rittling’s diversity and flexibility have freed architects from the constraints of designing around limited catalog selections of standard elements and enclosure configurations. Today Rittling engineers can draw on, or modify, any of 60 different hydronic heating elements...and 97 standard enclosure models... to build any system an architect can draw to tolerances of less than .015 inch... at an exceptionally competitive cost. For the architects of the future, Rittling will continue to advance finned tube technology in still more new directions... and develop ever more efficient, cost effective hydronic heat transfer systems. Over fifty years of quality, innovation and service... and we’re just getting warmed up. A Zehnder Group Company 2 REGENCY F-SERIES ENCLOSURES When appearance and flexibility of the heating installation are primary considerations, Regency F-Series enclosures offer thermal efficiency and an emphatic vertical stance with unobtrusive louvers and sleek, wall-hugging profiles. The five F-Series models can be supplied as either low-profile enclosures, for use where floor-to-sill clearance is minimal, or as standard-dimensioned units. These sturdy enclosures are available with fronts and tops of 14, 16, or 18-gauge cold rolled steel, in lengths from 1 to 8 feet in 6-inch increments, and heights to accommodate one to three finned tubes. Aluminum and stainless steel are also available. For Standard Application: FS and FT models For Specialized Heating Environments: FR, FF, FSOS and S-SL models. Rittling Accessories Custom-Fit Any Type of Installation Demands! A full line of accessories is available to insure a professional custom fit, including: • • • • • • • Full Height Back Panels Mounting Channels Self-Gauging, Snap Fit, Expansion Cradles Slip-In Pipe Hanger Wall Trim Supports 3½-inch End Caps • 12-inch wide End Caps with Access Door • Inside and Outside Corners (90°, 135°) • 12-inch wide Access Panels with Access Doors • 12-inch wide Removable Access Section • Control Dampers: Knob-type, Security Allenhead Operators • Custom Column Enclosures FEATURES AND RATINGS page FULL LINE OVERVIEW.............................................. 2-3 FS5/FS3 (Sloped Grille Enclosures)................................ 4-11 FT5/FT3 (Top Grille Enclosures)................................... 12-19 FF5/FF3 (Front Grille Enclosures)................................. 20-27 FR5/FR3 (Rounded Grille Enclosures)........................... 28-35 FSOS (Double Sloped Grille Enclosures)....................... 36-41 S-SL (Security Sloped Grille Enclosures)........................ 42-47 ACCESSORIES............................................................. 48-49 APPLICATIONS........................................................... 50-51 RATINGS CORRECTION DATA................................ 52-54 ENGINEERING SPECIFICATIONS........................... 55 WARRANTY................................................................. back cover FS5/FS3 - SLOPED GRILLE FS5 DIMENSIONS: Depth: 53⁄8 inches Height: 14, 20, 24 inches FS3 DIMENSIONS: Depth: 315⁄16 inches Height: 8, 11, 14 inches Applications: Designed for high heat output through a sloped louvered outlet. Recommended to prevent enclosure from being used as shelf or step. FT5/FT3 - TOP GRILLE FT5 DIMENSIONS: Depth: 53⁄8 inches Height: 14, 20, 24 inches FT3 DIMENSIONS: Depth: 315⁄16 inches Height: 8, 11, 14 inches Applications: Provide an even blanket of heated air through top louvers and emit radiant heat off the front of the cabinet. Ideal for exposed walls and large window areas. FF5/FF3 - FRONT GRILLE FF5 DIMENSIONS: Depth: 53⁄8 inches Height: 14, 20, 24 inches FF3 DIMENSIONS: Depth: 315⁄16 inches Height: 8, 11, 14 inches Applications: Provide heat through front panel louvers when installations require heated air to be diffused away from exterior walls. FR5/FR3 - ROUNDED GRILLE FR5 DIMENSIONS: Depth: 53⁄8 inches Height: 14, 20, 24 inches FR3 DIMENSIONS: Depth: 315⁄16 inches Height: 8, 11, 14 inches Applications: When high heat output is demanded into room and along exterior walls. Appealing enclosure design allows heat to radiate through louvers rounded along top and front edge of cabinet. FSOS - DOUBLE SLOPED GRILLE DIMENSIONS: Depth: 315⁄16 inches Height: 14 inches Depth: 53⁄8 inches Height: 18, 24 inches Applications: Double sloped panels provide required heat output when higher wall mounting is called for to restrict accessibility...such as in swimming pool areas and gymnasiums. S-SL - SECURITY SLOPED GRILLE DIMENSIONS: Depth: 53⁄8 inches Height: 12, 18, 24 inches Applications: Meet interior design specifications requiring consistent and even heat through conventional louvers and when security of enclosure is imperative. 3 FS5/FS3 ENCLOSURE SLOPED GRILLE ENCLOSURES BRACKET APPLICATION: Designed for high heat output through a sloped and louvered outlet. Recommended to prevent enclosure from being used as shelf or step. MOUNTING CHANNEL DETAIL TINNERMAN NUT ELEMENT: • Steel or copper/aluminum. • 1-foot to 12-foot lengths in 6-inch •increments. (10-foot maximum length • for steel.) • Galvanized fins .032 inches thick, • aluminum fins .016 inches thick. POSITIVE LOCKING BOTTOM MOUNTING CLIP DETAIL Cutaway view of FS5 enclosure showing 4 1⁄4" x 4 1⁄4" fin configuration. SECTION "X - X" "B" 1:1 INTERNAL JOGGLE-JOINER MOUNTING: • Mounting channel • Full back panel 20-gauge (18-gauge available) galvannealed steel. • Urethane gasket for air seal available. HANGERS: • Self-gauging, snap fit, expansion cradle • • with positive-locking, bottom-mounting • clip provides easy installation as well • as security. • 16-gauge galvannealed steel. • Slide cradle will accommodate 13⁄4 -inch •linear expansion for quiet operation. "B" "A" 6" WALL "A" WALL JOINTS: • Internal joggle joiners provide hairline •joints without any external fasteners. 6" DAMPER: • (Optional) Durable knob or security • tamper proof available. OPTIONAL LOUVERED INLETS: • Horizontal bottom inlet louvers -FSHL • Vertical louvered inlet-FSVL • Model FSN, no louvers (not shown) FIN ENCLOSURE ENCLOSURE: • 14 to 18-gauge primed, phosphatized CRS. • 1-foot to 8-foot lengths in 6-inch increments. • Powder coated finish in decorator colors • available. • Aluminum or stainless steel available. * 2-7/8" *2-7/8" 2-1/16" 2-5/8" 4" MIN. 4" MIN FLOOR FLOOR ARE BASED ON 1" COPPER TUBECOPPER TUBE *CENTERLINES BASED ON 1" * CENTERLINESARE ARE BASED ON 1"ON COPPER TUBE *CENTERLINES BASED 1" COPPER TUBE * CENTERLINESARE DAMPER OPTION IS DEPENDENT ON ENCLOSURE SIZE & PIPING CONFIGURATIONS. FS3 FS5 PIPE SIZE STEEL COPPER FSVL 4 FSHL FIN SIZE A B ⁄4", 1", 1 ⁄4" 2 ⁄4" X 4" 14" N/A 3 1 1", 1 ⁄4" ⁄4", 1", 11⁄4" 31⁄4" X 31⁄4" 20" 53⁄8" 1", 11⁄4", 2 3⁄4", 1", 11⁄4" 41⁄4" X 41⁄4" 24" 3 1 3 PIPE SIZE STEEL COPPER N/A 1", 11⁄4" FIN SIZE A B 3 ⁄4", 1", 11⁄4" 23⁄4" X 4" 8" 11" 315⁄16" 3 ⁄4", 1", 11⁄4" 31⁄4" X 31⁄4" 14" FS5 GUARANTEED RATINGS STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 770 790 1180 830 1230 1440 860 920 1290 950 1360 1570 950 1070 1440 1110 1500 1720 680 700 1040 730 1090 1280 760 810 1150 840 1200 1390 840 950 1280 980 1320 1520 600 620 920 650 960 1130 670 720 1010 740 1060 1230 740 840 1130 870 1170 1350 520 540 800 560 840 980 580 630 880 650 920 1060 650 730 980 750 1020 1170 STEEL FINNED TUBING 1" DIA. STEEL 1S-3¼ X 3¼-32 1S-3¼ X 3¼-40 1S-3¼ X 3¼-48 11⁄4" DIA. STEEL 1¼S-3¼ X 3¼-32 1¼S-3¼ X 3¼-40 1¼S-3¼ X 3¼-48 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.10 4.20 6.30 4.40 6.60 7.70 4.60 4.90 6.90 5.10 7.30 8.40 5.10 5.70 7.70 5.90 8.00 9.20 4.00 4.10 6.20 4.30 6.50 7.50 4.50 4.80 6.80 5.00 7.10 8.20 5.00 5.60 7.50 5.80 7.80 9.00 980 1010 1510 1060 1580 1850 1100 1180 1660 1220 1750 2020 1220 1370 1850 1420 1920 2210 960 980 1490 1030 1560 1800 1080 1150 1630 1200 1700 1970 1200 1340 1800 1390 1870 2160 750 760 1160 800 1220 1400 840 900 1270 940 1330 1540 940 1050 1400 1080 1460 1680 660 680 1030 710 1080 1240 750 790 1120 830 1170 1360 830 920 1240 960 1290 1490 590 600 910 630 950 1100 660 700 990 730 1040 1200 730 820 1100 850 1140 1320 510 520 790 550 830 950 570 610 860 640 900 1040 640 710 960 740 990 1140 IMPORTANT RATING INFORMATION Guaranteed ratings based on: • Installation at height shown. (Lower heights are not recommended; for greater heights, refer to Table 1 on page 52.) • Entering air temperature of 65°F. (For other temperatures, refer to Table 2 or Table 3 on page 52.) • Steam at nominal 1 (actual 0.9) psig and 215°F. (For other conditions, refer to Table 2 on page 52.) • Water average temperature (°F) shown and velocity of 3 fps or more. (For lower velocities, see Figure 1 on page 53.) • The interrelationships of water velocities, flow rates, pressure drops, and temperature drops with respect to total Btu requirements for various tube diameters appear in Figure 1 on page 53. • Linear expansion of steel and copper finned tube with temperature is shown in Figure 4 on page 54. 5 FS5 GUARANTEED RATINGS STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 980 1010 1520 1040 1590 1820 1090 1170 1670 1230 1740 1990 1240 1390 1840 1420 1900 2200 870 890 1350 920 1400 1610 960 1040 1480 1090 1540 1760 1100 1230 1620 1260 1680 1950 750 770 1170 800 1220 1400 840 900 1280 940 1340 1530 950 1070 1410 1090 1460 1690 960 990 1460 1030 1500 1740 1080 1150 1570 1190 1660 1900 1210 1310 1690 1390 1790 2060 850 880 1280 910 1330 1540 950 1010 1390 1060 1460 1680 1070 1160 1490 1230 1580 1820 740 760 1120 790 1160 1340 830 880 1210 920 1270 1460 930 1010 1300 1070 1370 1580 STEEL FINNED TUBING 1" DIA. STEEL 1S-41⁄4 X 41⁄4-32 1S-41⁄4 X 41⁄4-40 1S-41⁄4 X 41⁄4-48 11⁄4" DIA. STEEL 11⁄4S-41⁄4 X 41⁄4-32 11⁄4S-41⁄4 X 41⁄4-40 11⁄4S-41⁄4X 41⁄4-48 2" DIA. STEEL 2S-41⁄4 X 41⁄4-32 2S-41⁄4 X 41⁄4-40 2S-41⁄4 X 41⁄4-48 6 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.90 6.10 9.20 6.30 9.60 11.00 6.60 7.10 10.10 7.40 10.50 12.00 7.50 8.40 11.10 8.60 11.50 13.30 1420 1460 2210 1510 2300 2640 1580 1700 2420 1780 2520 2880 1800 2020 2660 2060 2760 3190 11110 1140 1720 1180 1790 2060 1230 1330 1890 1390 1970 2250 1400 1580 2070 1610 2150 2490 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.80 6.00 8.80 6.20 9.10 10.50 6.50 6.90 9.50 7.20 10.00 11.50 7.30 7.90 10.20 8.40 10.80 12.40 1390 1400 2110 1490 2180 2520 1560 1660 2280 1730 2400 2760 1750 1900 2450 2020 2590 2980 1080 1120 1650 1160 1700 1970 1220 1290 1790 1350 1870 2150 1370 1480 1910 1580 2020 2320 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.80 6.00 9.00 6.20 9.40 10.80 6.50 7.00 9.90 7.20 10.30 11.80 7.30 8.20 10.90 8.40 11.30 13.00 1390 1440 2160 1490 2260 2590 1560 1680 2380 1730 2470 2830 1750 1970 2620 2020 2710 3120 1080 1120 1680 1160 1760 2020 1220 1310 1860 1350 1930 2210 1370 1540 2040 1580 2110 2430 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 5. 960 990 1490 1030 1560 1790 1080 1160 1640 1190 1700 1950 1210 1360 1810 1390 1870 2150 850 880 1320 910 1380 1580 950 1020 1450 1060 1510 1730 1070 1200 1600 1230 1660 1900 740 760 1140 790 1200 1370 830 890 1260 920 1310 1500 930 1040 1390 1070 1440 1650 FS5 GUARANTEED RATINGS STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 COPPER FINNED TUBING ¾" DIA. COPPER ¾C-2¾ X 4-32 ¾C-2¾ X 4-40 ¾C-2¾ X 4-48 ¾C-3¼ X 3¼-40 3 ⁄4" DIA. COPPER ¾C-3¼ X 3¼-32 ¾C-3¼ X 3¼-48 ¾C-4¼ X 4¼-40 3 ⁄4" DIA. COPPER ¾C-4¼ X 4¼-32 ¾C-4¼X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.57 4.81 7.21 5.09 7.92 9.10 5.42 5.89 7.65 6.13 8.31 9.52 5.80 6.60 7.87 7.12 8.58 9.85 1096 1155 1729 1221 1901 2185 1300 1412 1835 1472 1993 2284 1393 1584 1888 1709 2059 2363 855 901 1349 952 1483 1704 1014 1102 1431 1148 1555 1781 1086 1236 1472 1333 1606 1843 756 797 1193 842 1312 1507 897 975 1266 1016 1375 1576 961 1093 1302 1179 1421 1630 668 705 1055 745 1159 1333 793 862 1119 898 1216 1393 849 966 1151 1043 1256 1441 581 612 916 647 1007 1158 689 749 972 780 1056 1210 738 840 1000 906 1091 1252 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.30 5.80 8.10 6.10 9.00 10.30 5.90 6.50 9.40 6.90 9.70 10.70 6.40 7.40 9.70 7.90 10.00 11.00 1270 1390 1940 1460 2160 2470 1420 1560 2260 1660 2330 2570 1540 1780 2330 1900 2400 2640 990 1080 1510 1140 1680 1930 1110 1220 1760 1290 1820 2000 1200 1390 1820 1480 1870 2060 880 960 1340 1010 1490 1700 980 1080 1560 1150 1610 1770 1060 1230 1610 1310 1660 1820 770 850 1180 890 1320 1510 870 950 1380 1010 1420 1570 940 1090 1420 1160 1460 1600 670 740 1030 770 1140 1310 750 830 1200 880 1230 1360 820 940 1230 1010 1270 1400 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 6.90 7.30 10.90 7.70 12.00 13.80 8.20 8.90 11.60 9.30 12.60 14.40 8.80 10.00 11.90 10.80 13.00 14.90 1660 1750 2620 1850 2880 3310 1970 2140 2780 2230 3020 3460 2110 2400 2860 2590 3120 3580 1290 1370 2040 1440 2250 2580 1540 1670 2170 1740 2360 2700 1650 1870 2230 2020 2430 2790 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 5. 1150 1210 1810 1280 1990 2280 1360 1480 1920 1540 2080 2390 1460 1660 1980 1790 2150 2470 1010 1070 1600 1130 1760 2020 1200 1300 1700 1360 1840 2110 1290 1460 1740 1580 1900 2180 880 930 1390 980 1530 1760 1040 1130 1470 1180 1600 1830 1120 1270 1520 1370 1650 1900 7 GUARANTEED RATINGS FS5 STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 COPPER FINNED TUBING 1" DIA. COPPER 1C-2¾ X 4-32 1C-2¾ X 4-40 1C-2¾ X 4-48 1" DIA. COPPER 1C-3¼ X 3¼-32 1C-3¼ X 3¼-40 1C-3¼ X 3¼-48 1" DIA. COPPER 1C-4¼ X 4¼-32 1C-4¼ X 4¼-40 1C-4¼ X 4¼-48 8 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.48 4.76 7.07 4.95 7.78 8.91 5.28 5.75 7.54 6.00 8.20 9.30 5.67 6.46 7.73 6.99 8.39 9.63 1076 1142 1696 1188 1868 2138 1267 1379 1808 1439 1967 2231 1360 1551 1855 1676 2013 2310 839 891 1323 927 1457 1668 988 1076 1411 1122 1534 1740 1060 1210 1447 1308 1570 1802 742 788 1170 820 1289 1475 874 952 1248 993 1357 1539 938 1070 1280 1157 1389 1594 656 696 1035 725 1139 1304 773 841 1103 878 1200 1361 829 946 1131 1023 1228 1409 570 605 899 630 990 1133 672 731 958 763 1042 1182 721 822 983 888 1067 1224 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 980 1070 1480 1120 1650 1890 1080 1200 1720 1270 1780 1980 1180 1350 1780 1440 1830 2020 860 950 1310 990 1460 1670 960 1060 1520 1120 1570 1750 1040 1190 1570 1280 1620 1790 660 730 1010 760 1120 1280 740 820 1170 860 1210 1350 800 920 1208 980 1250 1370 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 1250 1370 1900 1440 2110 2420 1390 1540 2210 1630 2280 2540 1510 1730 2280 1850 2350 2590 760 840 1160 880 1290 1480 850 940 1350 990 1390 1550 920 1060 1390 1130 1430 1580 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 5.20 5.70 7.90 6.00 8.80 10.10 5.80 6.40 9.20 6.80 9.50 10.60 6.30 7.20 9.50 7.70 9.80 10.80 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 6.80 7.20 10.70 7.50 11.80 13.50 8.00 8.70 11.40 9.10 12.40 14.10 8.60 9.80 11.70 10.60 12.70 14.60 1630 1730 2570 1800 2830 3240 1920 2090 2740 2180 2980 3380 2060 2350 2810 2540 3050 3500 1270 1350 2000 1400 2200 2530 1500 1630 2140 1700 2330 2640 1610 1830 2190 1980 2380 2730 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 5. 1120 1190 1770 1240 1950 2240 1320 1440 1890 1500 2060 2330 1420 1620 1940 1750 2100 2420 990 1060 1570 1100 1730 1980 1170 1270 1670 1330 1820 2060 1260 1430 1710 1550 1860 2140 860 920 1360 950 1500 1720 1020 1110 1450 1160 1580 1790 1090 1250 1490 1350 1620 1860 GUARANTEED RATINGS FS5 STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 COPPER FINNED TUBING 1¼" DIA. COPPER 1¼C-2¾ X 4-32 1¼C-2¾ X 4-40 1¼C-2¾ X 4-48 11⁄4" DIA. COPPER 1¼C-3¼ X 3¼-32 1¼C-3¼ X 3¼-40 1¼C-3¼ X 3¼-48 1¼" DIA. COPPER 1¼C-4¼ X 4¼-32 1¼C-4¼ X 4¼-40 1¼C-4¼ X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.43 4.68 6.93 4.90 7.65 8.77 5.23 5.67 7.40 5.94 8.06 9.19 5.61 6.41 7.59 6.88 8.25 9.52 1063 1122 1663 1175 1835 2105 1254 1360 1775 1426 1934 2204 1346 1538 1822 1650 1980 2284 829 875 1297 916 1431 1642 978 1060 1385 1112 1508 1719 1050 1199 1421 1287 1544 1781 733 774 1148 811 1266 1453 865 938 1225 984 1334 1521 929 1061 1257 1139 1366 1576 648 684 1015 717 1119 1284 765 829 1083 870 1180 1345 821 938 1111 1007 1208 1393 563 595 881 623 972 1116 665 721 941 756 1025 1168 714 815 965 875 1049 1210 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.80 5.50 7.70 5.80 8.60 9.90 5.70 6.20 9.00 6.50 9.30 10.40 6.10 7.10 9.30 7.60 9.60 10.70 1150 1320 1850 1390 2060 2380 1370 1490 2160 1560 2230 2500 1460 1700 2230 1820 2300 2570 900 1030 1400 1080 1610 1860 1070 1160 1680 1220 1740 1950 1140 1330 1740 1420 1790 2000 790 910 1280 960 1420 1640 950 1030 1490 1080 1540 1720 1040 1170 1540 1260 1590 1770 700 810 1130 850 1260 1450 840 910 1320 950 1360 1530 890 1040 1360 1110 1400 1570 610 700 980 740 1090 1260 730 790 1140 830 1180 1330 770 900 1180 960 1220 1360 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 6.70 7.10 10.50 7.40 11.60 13.30 7.90 8.60 11.20 9.00 12.20 13.90 8.50 9.70 11.50 10.40 12.50 14.40 1610 1700 2520 1780 2780 3190 1900 2060 2690 2160 2930 3340 2040 2330 2760 2500 3000 3460 1260 1330 1970 1390 2170 2490 1480 1610 2100 1680 2290 2610 1590 1820 2150 1950 2340 2700 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 5. 1110 1170 1740 1230 1920 2200 1310 1420 1860 1490 2020 2300 1410 1610 1900 1720 2070 2390 980 1040 1540 1090 1700 1950 1160 1260 1640 1320 1790 2040 1240 1420 1680 1530 1830 2110 850 900 1340 940 1480 1690 1010 1090 1430 1140 1550 1770 1080 1230 1460 1330 1590 1830 9 GUARANTEED RATINGS FS3 LOW PROFILE In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 620 660 690 940 670 730 760 1050 760 830 860 1180 550 580 610 830 590 650 680 920 680 730 760 1040 480 510 540 730 520 570 600 820 600 650 670 920 420 450 470 640 460 500 520 710 520 560 580 800 650 690 730 990 700 760 810 1100 760 830 880 1200 560 600 640 860 610 660 700 950 660 720 760 1040 STEEL FINNED TUBING 11⁄4" DIA. STEEL 1" DIA. STEEL 1S-3¼ X 3¼-32 1S-3¼ X 3¼-40 1S-3¼ X 3¼-48 1¼S-3¼ X 3¼-32 1¼S-3¼ X 3¼-40 1¼S-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 3.30 3.50 3.70 5.00 3.60 3.90 4.10 5.60 4.10 4.40 4.60 6.30 3.20 3.40 3.60 4.90 3.50 3.80 4.00 5.50 4.00 4.30 4.50 6.20 790 840 890 1200 860 940 980 1340 980 1060 1100 1510 770 820 860 1180 840 910 960 1320 960 1030 1080 1490 600 640 670 920 660 710 750 1030 750 800 840 1160 530 570 590 810 580 630 660 910 9660 710 750 1030 470 500 520 720 510 560 590 810 590 630 660 910 410 430 460 630 450 480 510 700 510 550 570 790 3 ⁄4" DIA. COPPER 3 ⁄4" DIA. COPPER COPPER FINNED TUBING ¾C-2¾ X 4-32 ¾C-2¾ X 4-40 ¾C-2¾ X 4-48 ¾C-3¼ X 3¼-32 ¾C-3¼ X 3¼-40 ¾C-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 4.40 4.70 5.00 6.80 4.80 5.20 5.50 7.50 5.20 5.70 6.00 8.20 4.20 4.50 4.70 6.40 4.50 4.90 5.20 7.10 5.00 5.40 5.70 7.90 1060 1130 1200 1630 1150 1240 1320 1800 1240 1360 1440 1970 1010 1080 1130 1540 1080 1180 1250 1700 1200 1300 1370 1900 830 880 940 1270 900 970 1030 1400 970 1060 1120 1540 790 840 880 1200 840 920 980 1330 940 1010 1070 1480 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 5. 10 730 780 830 1120 790 850 910 1240 850 940 990 1360 700 750 780 1060 750 810 860 1170 830 900 950 1310 620 660 690 940 660 720 760 1040 730 790 840 1160 540 570 600 820 570 630 660 900 640 690 730 1010 GUARANTEED RATINGS FS3 LOW PROFILE In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 630 670 720 980 690 740 790 1090 740 820 870 1180 550 580 630 850 600 650 690 940 650 710 750 1030 600 650 690 940 670 720 760 1040 730 790 840 1140 520 560 600 820 580 630 660 900 640 690 730 990 1" DIA. COPPER COPPER FINNED TUBING 1C-2¾ X 4-32 1C-2¾ X 4-40 1C-2¾ X 4-48 11⁄4" DIA. COPPER 11⁄4" DIA. COPPER 1" DIA. COPPER 1C-3¼ X 3¼-32 1C-3¼ X 3¼-40 1C-3¼ X 3¼-48 1¼C-2¾ X 4-32 1¼C-2¾ X 4-40 1¼C-2¾ X 4-48 1¼C-3¼ X 3¼-32 1¼C-3¼ X 3¼-40 1¼C-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 4.30 4.60 4.90 6.70 4.70 5.10 5.40 7.40 5.10 5.60 5.90 8.10 1030 1100 1180 1610 1130 1220 1300 1780 1220 1340 1420 1940 800 860 920 1260 880 950 1010 1390 950 1050 1110 1510 710 760 810 1110 780 840 900 1230 840 920 980 1340 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 4.10 4.40 4.70 6.40 4.60 4.90 5.20 7.10 5.00 5.40 5.70 7.80 980 1060 1130 1540 1100 1180 1250 1700 1200 1300 1370 1870 760 830 880 1200 860 920 980 1330 940 1010 1070 1460 680 730 780 1060 760 810 860 1170 830 900 950 1290 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 4.10 4.40 4.70 6.40 4.50 4.90 5.20 7.10 5.00 5.40 5.70 7.80 3.60 3.90 4.10 5.60 4.50 4.80 5.10 7.00 4.90 5.30 5.60 7.70 980 1060 1130 1540 1080 1180 1250 1700 1200 1300 1370 1870 860 940 980 1340 1080 1150 1220 1680 1180 1270 1340 1850 760 830 880 1200 840 920 980 1330 940 1010 1070 1460 670 730 760 1050 840 900 950 1310 920 990 1050 1440 680 730 780 1060 750 810 860 1170 830 900 950 1290 590 650 680 920 750 790 840 1160 810 880 920 1280 600 650 690 940 660 720 760 1040 730 790 840 1140 520 570 600 820 660 700 740 1020 720 770 820 1130 520 560 600 820 570 630 660 900 640 690 730 990 460 500 520 710 570 610 650 890 630 670 710 980 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 5. 11 FT5/FT3 ENCLOSURE TOP GRILLE ENCLOSURES BRACKET APPLICATION: Provide an even blanket of heated air through top louvers and emit radiant heat off the front of the cabinet. Ideal for exposed walls and large window areas. MOUNTING CHANNEL DETAIL ELEMENT: • Steel or copper/aluminum. • 1-foot to 12-foot lengths in 6-inch •increments. (10-foot maximum length • for steel.) • Galvanized fins .032 inches thick, • aluminum fins .016 inches thick. POSITIVE LOCKING BOTTOM MOUNTING CLIP DETAIL Cutaway view of FT5 enclosure showing 4 1⁄4" x 4 1⁄4" fin configuration. SECTION "X - X" "B" INTERNAL JOGGLE-JOINER DAMPER OPTIONAL MOUNTING: • Mounting channel • Full back panel 20-gauge (18-gauge available) galvannealed steel. • Urethane gasket for air seal available. HANGERS: • Self-gauging, snap fit, expansion cradle • • with positive-locking, bottom-mounting • clip provides easy installation as well • as security. • 16-gauge galvannealed steel. • Slide cradle will accommodate 13⁄4 -inch •linear expansion for quiet operation. "B" DAMPER OPTIONAL 6" WALL JOINTS: • Internal joggle joiners provide hairline •joints without any external fasteners. "A" "A" WALL 6" DAMPER: • (Optional) Durable knob or security • tamper proof available. OPTIONAL LOUVERED INLETS: • Horizontal bottom inlet louvers -FTHL • Vertical louvered inlet-FTVL • Model FTN, no louvers (not shown) FIN ENCLOSURE TINNERMAN NUT ENCLOSURE: • 14 to 18-gauge primed, phosphatized CRS. • 1-foot to 8-foot lengths in 6-inch increments. • Powder coated finish in decorator colors • available. • Aluminum or stainless steel available. * 2-7/8" * 2-7/8" 2-1/16" 2-5/8" FLOOR 4" MIN. 4" MIN FLOOR ARE BASED ON 1" COPPER TUBE * CENTERLINES ARE BASED ON 1" COPPER TUBE * CENTERLINESDAMPER OPTION IS DEPENDENT ON ENCLOSURE SIZE & PIPING CONFIGURATIONS. FT3 FT5 PIPE SIZE STEEL COPPER FTHL 12 FTVL FIN SIZE A B ⁄4", 1", 1 ⁄4" 2 ⁄4" x 4" 14" N/A 1", 11⁄4" 3⁄4", 1", 11⁄4" 31⁄4" x 31⁄4" 20" 53⁄8" 1", 11⁄4", 2 3⁄4", 1", 11⁄4" 41⁄4" x 41⁄4" 24" 3 1 3 PIPE SIZE STEEL COPPER N/A 1", 11⁄4" FIN SIZE A B 8" 11" 315⁄16" 3 ⁄4", 1", 11⁄4" 31⁄4" x 31⁄4" 14" 3 ⁄4", 1", 11⁄4" 23⁄4" x 4" GUARANTEED RATINGS FT5 STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F Rows Of Finned Tube (On 6-inch Centers) FINNED TUBE MODEL Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 750 760 1160 800 1220 1400 840 900 1270 940 1330 1550 940 1050 1400 1080 1440 1650 660 680 1030 710 1080 1240 750 790 1120 830 1170 1370 830 920 1240 960 1280 1460 590 600 910 630 950 1100 660 700 990 730 1040 1210 730 820 1100 850 1130 1290 510 520 790 550 830 960 570 610 860 640 900 1050 640 710 950 740 980 1120 STEEL FINNED TUBING 1" DIA. STEEL 1S-3¼ X 3¼-32 1S-3¼ X 3¼-40 1S-3¼ X 3¼-48 11⁄4" DIA. STEEL 1¼S-3¼ X 3¼-32 1¼S-3¼ X 3¼-40 1¼S-3¼ X 3¼-48 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.00 4.10 6.20 4.30 6.50 7.50 4.50 4.80 6.80 5.00 7.10 8.30 5.00 5.60 7.50 5.80 7.70 8.80 3.90 4.00 6.10 4.20 6.40 7.40 4.40 4.70 6.70 4.90 7.00 8.10 4.90 5.50 7.40 5.70 7.60 8.70 960 980 1490 1030 1560 1800 1080 1150 1630 1200 1700 1990 1200 1340 1800 1390 1850 2110 940 960 1460 1010 1540 1780 1060 1130 1610 1180 1680 1940 1180 1320 1780 1370 1820 2090 730 750 1140 790 1200 1390 830 880 1260 920 1310 1510 920 1030 1390 1070 1420 1630 650 660 1010 700 1060 1230 730 780 1110 810 1160 1340 810 910 1230 950 1260 1440 570 590 890 620 940 1090 650 690 980 720 1020 1180 720 810 1090 840 1110 1270 500 510 770 540 820 940 560 600 850 630 890 1030 630 700 940 730 960 1110 IMPORTANT RATING INFORMATION Guaranteed ratings based on: • Installation at height shown. (Lower heights are not recommended; for greater heights, refer to Table 1 on page 52.) • Entering air temperature of 65°F. (For other temperatures, refer to Table 2 or Table 3 on page 52.) • Steam at nominal 1 (actual 0.9) psig and 215°F. (For other conditions, refer to Table 2 on page 52.) • Water average temperature (°F) shown and velocity of 3 fps or more. (For lower velocities, see Figure 1 on page 53.) • The interrelationships of water velocities, flow rates, pressure drops, and temperature drops with respect to total Btu requirements for various tube diameters appear in Figure 1 on page 53. • Linear expansion of steel and copper finned tube with temperature is shown in Figure 4 on page 54. 13 GUARANTEED RATINGS FT5 STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 850 880 1320 910 1380 1580 950 1020 1450 1060 1510 1730 1070 1200 1600 1230 1650 1920 740 760 1140 790 1200 1370 830 890 1260 920 1310 1500 930 1040 1390 1070 1440 1660 840 870 1260 890 1310 1490 940 990 1360 1040 1430 1650 1060 1130 1460 1200 1550 1790 730 750 1090 770 1130 1300 820 860 1180 900 1250 1440 920 980 1270 1040 1350 1550 STEEL FINNED TUBING 1" DIA. STEEL 1S-4¼ X 4¼-32 1S-4¼ X 4¼-40 1S-4¼ X 4¼-48 11⁄4" DIA. STEEL 1¼S-4¼ X 4¼-32 1¼S-4¼ X 4¼-40 1¼S-4¼ X 4¼-48 2" DIA. STEEL 2S-4¼ X 4¼-32 2S-4¼ X 4¼-40 2S-4¼ X 4¼-48 14 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.80 6.00 9.00 6.20 9.40 10.80 6.50 7.00 9.90 7.20 10.30 11.80 7.30 8.20 10.90 8.40 11.30 13.10 1390 1440 2160 1490 2260 2590 1560 1680 2380 1730 2470 2830 1750 1970 2620 2020 2710 3140 1080 1120 1680 1160 1760 2020 1220 1310 1860 1350 1930 2210 1370 1540 2040 1580 2110 2450 960 990 1490 1030 1560 1790 1080 1160 1640 1190 1700 1950 1210 1360 1810 1390 1870 2170 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.70 5.90 8.60 6.10 8.90 10.20 6.40 6.80 9.30 7.10 9.80 11.30 7.20 7.70 10.00 8.20 10.60 12.20 1370 1420 2060 1460 2140 2450 1540 1630 2230 1700 2350 2710 1730 1850 2400 1970 2540 2930 1070 1110 1610 1140 1670 1910 1200 1270 1740 1330 1830 2110 1350 1440 1870 1540 1980 2290 950 980 1420 1010 1480 1690 1060 1120 1540 1170 1620 1870 1190 1280 1660 1360 1750 2020 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.70 5.90 8.80 6.10 9.20 10.60 6.40 6.90 9.70 7.10 10.10 11.60 7.20 8.00 10.70 8.20 11.10 12.80 1370 1420 2110 1460 2210 2540 1540 1660 2330 1700 2420 2780 1730 1920 2570 1970 2660 3070 1070 1110 1650 1140 1720 1980 1200 1290 1820 1330 1890 2170 1350 1500 2000 1540 2070 2390 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 13. 950 980 1460 1010 1520 1750 1060 1150 1610 1170 1670 1920 1190 1320 1770 1360 1840 2120 840 870 1290 890 1350 1550 940 1010 1420 1040 1480 1700 1060 1170 1570 1200 1620 1870 730 750 1120 770 1170 1350 820 880 1230 900 1280 1470 920 1020 1360 1040 1410 1630 GUARANTEED RATINGS FT5 STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 COPPER FINNED TUBING ¾C-2¾ X 4-40 3 ⁄4" DIA. COPPER ¾C-2¾ X 4-32 ¾C-2¾ X 4-48 ¾C-3¼ X 3¼-40 3 ⁄4" DIA. COPPER ¾C-3¼X 3¼-32 ¾C-3¼ X 3¼-48 ¾C-4¼ X 4¼-40 3 ⁄4" DIA. COPPER ¾C-4¼ X 4¼-32 ¾C-4¼ X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.48 4.76 7.07 4.95 7.78 8.97 5.23 5.75 7.73 6.00 8.44 9.63 5.67 6.55 9.10 6.99 9.71 10.84 1076 1142 1696 1188 1868 2152 1254 1379 1855 1439 2026 2310 1360 1571 2185 1676 2330 2600 839 891 1323 927 1457 1678 978 1076 1447 1122 1580 1802 1060 1225 1704 1308 1817 2028 742 788 1170 820 1289 1485 865 952 1280 993 1398 1594 938 1084 1507 1157 1608 1794 656 696 1035 725 1139 1312 765 841 1131 878 1236 1409 829 958 1333 1023 1421 1586 570 605 899 630 990 1140 665 731 983 763 1074 1224 721 833 1158 888 1235 1378 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.20 5.70 7.50 6.00 8.40 9.60 5.80 6.40 8.80 6.80 9.20 10.60 6.40 7.30 8.50 7.90 9.50 11.00 1250 1370 1800 1440 2020 2300 1390 1540 2110 1630 2210 2540 1540 1750 2040 1900 2280 2640 980 1070 1400 1120 1580 1790 1080 1200 1650 1270 1720 1980 1200 1370 1590 1480 1780 2060 1270 1350 2000 1400 2210 2540 1480 1630 2190 1700 2390 2730 1610 1860 2580 1980 2750 3070 860 950 1240 990 1390 1590 960 1060 1460 1120 1520 1750 1060 1210 1410 1310 1570 1820 760 840 1100 880 1230 1400 850 940 1290 990 1350 1550 940 1070 1240 1160 1390 1610 660 730 950 760 1070 1220 740 820 1120 860 1170 1350 820 930 1080 1010 1210 1400 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 6.80 7.20 10.70 7.50 11.80 13.60 7.90 8.70 11.70 9.10 12.80 14.60 8.60 9.90 13.80 10.60 14.70 16.40 1630 1730 2570 1800 2830 3260 1900 2090 2810 2180 3070 3500 2060 2380 3310 2540 3530 3940 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 13. 1120 1190 1770 1240 1950 2250 1310 1440 1940 1500 2120 2420 1420 1640 2280 1750 2440 2720 990 1060 1570 1100 1730 1990 1160 1270 1710 1330 1870 2140 1260 1450 2020 1550 2150 2400 860 920 1360 950 1500 1730 1010 1110 1490 1160 1630 1860 1090 1260 1750 1350 1870 2090 15 GUARANTEED RATINGS FT5 STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 829 875 1297 916 1431 1642 963 1050 1421 1102 1544 1766 1040 1199 1668 1287 1781 1987 733 774 1148 811 1266 1453 852 929 1257 975 1366 1562 920 1061 1475 1139 1576 1758 648 684 1015 717 1119 1284 753 821 1111 862 1208 1381 813 938 1304 1007 1393 1554 563 595 881 623 972 1116 654 714 965 749 1049 1200 707 815 1133 875 1210 1350 COPPER FINNED TUBING 1" DIA. COPPER 1C-2¾ X 4-32 1C-2¾ X 4-40 1C-2¾ X 4-48 1" DIA. COPPER 1C-3¼ X 3¼-32 1C-3¼ X 3¼-40 1C-3¼ X 3¼-48 1" DIA. COPPER 1C-4¼ X 4¼-32 1C-4¼ X 4¼-40 1C-4¼ X 4¼-48 16 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.43 4.68 6.93 4.90 7.65 8.77 5.14 5.61 7.59 5.89 8.25 9.43 5.56 6.41 8.91 6.88 9.52 10.62 5.10 5.60 7.40 5.90 8.20 9.40 5.70 6.30 8.60 6.70 9.00 10.30 6.30 7.20 8.30 7.70 9.30 10.80 6.70 7.10 10.50 7.40 11.60 13.30 7.80 8.50 11.50 8.90 12.50 14.30 8.40 9.70 13.50 10.40 14.40 16.10 1063 1122 1663 1175 1835 2105 1234 1346 1822 1412 1980 2264 1333 1538 2138 1650 2284 2548 1220 1340 1780 1420 1970 2260 1370 1510 2060 1610 2160 2470 1510 1730 1990 1850 2230 2590 1610 1700 2520 1780 2780 3190 1870 2040 2760 2140 3000 3430 2020 2330 3240 2500 3460 3860 950 1050 1390 1110 1540 1760 1070 1180 1610 1260 1680 1930 1180 1350 1550 1440 1740 2020 1260 1330 1970 1390 2170 2490 1460 1590 2150 1670 2340 2680 1580 1820 2530 1950 2700 3010 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 13. 840 920 1230 980 1360 1560 950 1040 1420 1110 1490 1700 1040 1190 1370 1280 1540 1790 1110 1170 1740 1230 1920 2200 1290 1410 1900 1480 2070 2370 1390 1610 2240 1720 2390 2660 740 820 1090 870 1200 1380 840 920 1260 980 1320 1510 920 1060 1210 1130 1360 1580 980 1040 1540 1090 1700 1950 1140 1240 1680 1310 1830 2090 1230 1420 1980 1530 2110 2350 650 710 940 750 1040 1120 730 800 1090 850 1140 1310 800 920 1060 980 1180 1370 850 900 1340 940 1470 1690 990 1080 1460 1130 1590 1820 1070 1230 1720 1330 1830 2050 GUARANTEED RATINGS FT5 STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 1043 1109 1630 1155 1808 2072 1221 1333 1789 1393 1947 2231 1313 1505 2092 1617 2251 2501 813 865 1272 901 1411 1616 952 1040 1395 1086 1519 1740 1024 1174 1632 1261 1755 1951 720 765 1125 797 1248 1430 842 920 1234 961 1343 1539 906 1038 1444 1116 1553 1726 636 676 994 705 1103 1264 745 813 1091 849 1188 1361 801 918 1276 986 1373 1526 553 588 864 612 958 1098 647 707 948 738 1032 1182 696 798 1109 857 1193 1326 1580 1680 2470 1750 2740 3140 1850 2020 2710 2110 2950 3380 1990 2280 3170 2450 3410 3790 1230 1310 1930 1370 2140 2450 1440 1580 2110 1650 2300 2640 1550 1780 2470 1910 2660 2960 960 1020 1510 1070 1670 1920 1130 1230 1650 1290 1800 2060 1210 1390 1930 1490 2080 2310 840 890 1310 930 1450 1660 980 1070 1440 1120 1560 1790 1050 1210 1680 1300 1810 2010 COPPER FINNED TUBING 11⁄4" DIA. COPPER 1¼C-2¾ X 4-32 1¼C-2¾ X 4-40 1¼C-2¾ X 4-48 11⁄4" DIA. COPPER 1¼C-3¼ X 3¼-32 1¼C-3¼ X 3¼-40 1¼C-3¼ X 3¼-48 11⁄4" DIA. COPPER 1¼C-4¼ X 4¼-32 1¼C-4¼ X 4¼-40 1¼C-4¼ X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.35 4.62 6.79 4.81 7.54 8.64 5.09 5.56 7.45 5.80 8.11 9.30 5.47 6.27 8.72 6.74 9.38 10.42 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 6.60 7.00 10.30 7.30 11.40 13.10 7.70 8.40 11.30 8.80 12.30 14.10 8.30 9.50 13.20 10.20 14.20 15.80 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.00 5.50 7.30 5.80 8.10 9.30 5.60 6.10 8.40 6.40 8.80 10.10 6.20 7.10 8.10 7.50 9.10 10.50 1200 1320 1750 1390 1940 2230 1340 1460 2020 1540 2110 2420 1490 1700 1940 1800 2180 2520 940 1030 1370 1080 1510 1740 1050 1140 1580 1200 1650 1890 1160 1330 1510 1400 1700 1970 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 13. 830 910 1210 960 1340 1540 920 1010 1390 1060 1460 1670 1030 1170 1340 1240 1500 1740 1090 1160 1700 1210 1890 2170 1280 1390 1870 1460 2040 2330 1370 1570 2190 1690 2350 2620 730 810 1070 850 1180 1360 820 890 1230 940 1290 1480 910 1040 1180 1100 1330 1540 640 700 930 740 1030 1180 710 770 1070 820 1120 1280 790 900 1030 950 1160 1340 17 GUARANTEED RATINGS FT3 LOW PROFILE In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 600 640 660 900 660 730 750 1010 750 800 840 1140 530 570 580 790 580 650 660 900 660 710 750 1010 470 500 510 700 510 570 590 790 590 630 660 890 410 430 450 610 450 500 510 680 510 540 570 770 800 860 920 1260 880 950 1010 1390 950 1050 1100 1500 710 760 810 1110 780 840 900 1230 840 920 980 1320 630 670 720 980 690 740 790 1090 740 820 870 1170 550 580 630 850 600 650 690 940 650 710 750 1020 STEEL FINNED TUBING 11⁄4" DIA. STEEL 1" DIA. STEEL 1S-3¼ X 3¼-32 1S-3¼ X 3¼-40 1S-3¼ X 3¼-48 1¼S-3¼ X 3¼-32 1¼S-3¼ X 3¼-40 1¼S-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 3.20 3.40 3.50 4.80 3.50 3.90 4.00 5.40 4.00 4.30 4.50 6.10 3.10 3.30 3.40 4.70 3.40 3.80 3.90 5.30 3.90 4.20 4.40 6.00 770 820 840 1150 840 940 960 1300 960 1030 1080 1460 740 790 820 1130 820 910 940 1270 940 1010 1060 1440 580 620 640 880 640 710 730 990 730 790 830 1120 510 550 570 780 570 630 650 880 650 700 730 990 450 480 500 690 500 560 570 770 570 620 650 880 390 420 430 600 430 480 500 670 500 540 560 760 3 ⁄4" DIA. COPPER 3 ⁄4" DIA. COPPER COPPER FINNED TUBING ¾C-2¾ X 4-32 ¾C-2¾ X 4-40 ¾C-2¾ X 4-48 ¾C-3¼ X 3¼-32 ¾C-3¼ X 3¼-40 ¾C-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 4.30 4.60 4.90 6.70 4.70 5.10 5.40 7.40 5.10 5.60 5.90 8.00 4.10 4.40 4.70 6.40 4.50 4.90 5.20 7.10 5.00 5.40 5.70 7.80 1030 1100 1180 1610 1130 1220 1300 1780 1220 1340 1420 1920 980 1060 1130 1540 1080 1180 1250 1700 1200 1300 1370 1870 760 830 880 1200 840 920 980 1330 940 1010 1070 1460 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 13. 18 680 730 780 1060 750 810 860 1170 830 900 950 1290 600 650 690 940 660 720 760 1040 730 790 840 1140 520 560 600 820 570 630 660 900 640 690 730 990 GUARANTEED RATINGS FT3 LOW PROFILE In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 620 660 700 960 680 730 770 1070 730 810 850 1160 540 570 610 840 590 640 670 930 640 700 740 1010 600 650 690 950 660 720 760 1060 720 790 840 1140 520 560 600 830 570 630 660 920 630 690 730 990 11⁄4" DIA. COPPER 11⁄4" DIA. COPPER 1" DIA. COPPER 1" DIA. COPPER COPPER FINNED TUBING 1C-2¾ X 4-32 1C-2¾ X 4-40 1C-2¾ X 4-48 1C-3¼ X 3¼-32 1C-3¼ X 3¼-40 1C-3¼ X 3¼-48 1¼C-23⁄4 X 4-32 1¼C-23⁄4 X 4-40 1¼C-23⁄4 X 4-48 1¼C-3¼ X 3¼-32 1¼C-3¼ X 3¼-40 1¼C-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 4.20 4.50 4.80 6.60 4.60 5.00 5.30 7.30 5.00 5.50 5.80 7.90 1010 1080 1150 1580 1110 1200 1270 1750 1200 1320 1390 1900 790 840 900 1230 870 940 990 1370 940 1030 1080 1480 700 750 790 1090 770 830 880 1210 830 910 960 1310 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 4.10 4.40 4.70 6.50 4.50 4.90 5.20 7.20 4.90 5.40 5.70 7.80 980 1060 1130 1560 1080 1180 1250 1730 1180 1300 1370 1870 760 830 880 1220 840 920 980 1350 920 1010 1070 1460 680 730 780 1080 750 810 860 1190 810 900 950 1290 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 4.00 4.30 4.60 6.30 4.40 4.80 5.10 7.00 4.90 5.30 5.60 7.70 3.50 3.80 4.00 5.50 4.40 4.70 5.00 6.90 4.80 5.20 5.50 7.50 960 1030 1100 1510 1060 1150 1220 1680 1180 1270 1340 1850 840 910 960 1320 1060 1130 1200 1660 1150 1250 1320 1800 750 800 860 1180 830 900 950 1310 920 990 1050 1440 660 710 750 1030 830 880 940 1290 900 980 1030 1400 660 710 760 1040 730 790 840 1160 810 880 920 1280 580 630 660 910 730 780 830 1150 790 860 910 1240 590 630 670 920 650 700 740 1020 720 770 820 1130 510 560 590 810 650 690 730 1010 700 760 810 1100 510 550 580 800 560 610 650 890 630 670 710 980 450 480 510 700 560 600 640 880 610 660 700 950 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 13. 19 FF5/FF3 ENCLOSURE FRONT GRILLE ENCLOSURES BRACKET APPLICATION: Provide heat through front panel louvers when installations require heated air to be diffused away from exterior walls. TINNERMAN NUT ENCLOSURE: • 14 to 18-gauge primed, phosphatized CRS. • 1-foot to 8-foot lengths in 6-inch increments. • Powder coated finish in decorator colors • available. • Aluminum or stainless steel available. ELEMENT: • Steel or copper/aluminum. • 1-foot to 12-foot lengths in 6-inch •increments. (10-foot maximum length • for steel.) • Galvanized fins .032 inches thick, • aluminum fins .016 inches thick. FIN ENCLOSURE MOUNTING CHANNEL DETAIL POSITIVE LOCKING BOTTOM MOUNTING CLIP DETAIL Cutaway view of FF5 enclosure showing 4 1⁄4" x 4 1⁄4" fin configuration. SECTION "X - X" INTERNAL JOGGLE-JOINER MOUNTING: • Mounting channel • Full back panel 20-gauge (18-gauge available) galvannealed steel. • Urethane gasket for air seal available. HANGERS: • Self-gauging, snap fit, expansion cradle • • with positive-locking, bottom-mounting • clip provides easy installation as well • as security. • 16-gauge galvannealed steel. • Slide cradle will accommodate 13⁄4 -inch •linear expansion for quiet operation. JOINTS: • Internal joggle joiners provide hairline •joints without any external fasteners. DAMPER: • (Optional) Durable knob or security • tamper proof available. OPTIONAL LOUVERED INLETS: • Horizontal bottom inlet louvers -FFHL • Vertical louvered inlet-FFVL *CENTERLINES ARE BASED ON 1" COPPER TUBE *CENTERLINES ARE BASED ON 1" COPPER TUBE DAMPER OPTION IS DEPENDENT ON ENCLOSURE SIZE & PIPING CONFIGURATIONS. FF3 FF5 PIPE SIZE STEEL COPPER FFHL5 20 FFVL5 FIN SIZE A B ⁄4", 1", 1 ⁄4" 2 ⁄4" X 4" 14" N/A 1", 11⁄4" 3⁄4", 1", 11⁄4" 31⁄4" X 31⁄4" 20" 53⁄8" 1", 11⁄4", 2 3⁄4", 1", 11⁄4" 41⁄4" X 41⁄4" 24" 3 1 3 PIPE SIZE STEEL COPPER N/A 1", 11⁄4" FIN SIZE A B 8" 11" 315⁄16" 3 ⁄4", 1", 11⁄4" 31⁄4" X 31⁄4" 14" 3 ⁄4", 1", 11⁄4" 23⁄4" X 4" GUARANTEED RATINGS FF5 LOW PROFILE In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F Rows Of Finned Tube (On 6-inch Centers) FINNED TUBE MODEL Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 730 750 1140 790 1200 1390 830 880 1260 920 1310 1510 920 1030 1390 1070 1420 1630 650 660 1010 700 1060 1230 730 780 1110 810 1160 1340 810 910 1230 950 1260 1440 570 590 890 620 940 1090 650 690 980 720 1020 1180 720 810 1090 840 1110 1270 500 510 770 540 820 940 560 600 850 630 890 1030 630 700 940 730 960 1110 STEEL FINNED TUBING 1" DIA. STEEL 1S-3¼ X 3¼-32 1S-3¼ X 3¼-40 1S-3¼ X 3¼-48 11⁄4" DIA. STEEL 1¼S-3¼ X 3¼-32 1¼S-3¼ X 3¼-40 1¼S-3¼ X 3¼-48 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 3.90 4.00 6.10 4.20 6.40 7.40 4.40 4.70 6.70 4.90 7.00 8.10 4.90 5.50 7.40 5.70 7.60 8.70 3.80 3.90 6.00 4.10 6.30 7.30 4.30 4.60 6.60 4.80 6.90 8.00 4.80 5.40 7.30 5.60 7.50 8.60 940 960 1460 1010 1540 1780 1060 1130 1610 1180 1680 1940 1180 1320 1780 1370 1820 2090 900 940 1440 980 1510 1750 1030 1100 1580 1150 1660 1930 1150 1300 1750 1340 1800 2060 700 730 1120 760 1180 1370 800 860 1230 900 1290 1510 900 1010 1370 1050 1400 1610 620 650 990 680 1040 1210 710 760 1090 790 1150 1330 790 900 1210 920 1240 1420 550 570 880 600 920 1070 630 670 960 700 1010 1180 700 790 1070 820 1100 1260 480 500 760 520 800 930 550 580 840 610 880 1020 610 690 930 710 950 1090 IMPORTANT RATING INFORMATION Guaranteed ratings based on: • Installation at height shown. (Lower heights are not recommended; for greater heights, refer to Table 1 on page 52.) • Entering air temperature of 65°F. (For other temperatures, refer to Table 2 or Table 3 on page 52.) • Steam at nominal 1 (actual 0.9) psig and 215°F. (For other conditions, refer to Table 2 on page 52.) • Water average temperature (°F) shown and velocity of 3 fps or more. (For lower velocities, see Figure 1 on page 53.) • The interrelationships of water velocities, flow rates, pressure drops, and temperature drops with respect to total Btu requirements for various tube diameters appear in Figure 1 on page 53. • Linear expansion of steel and copper finned tube with temperature is shown in Figure 4 on page 54. 21 GUARANTEED RATINGS FF5 In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STANDARD STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 840 870 1290 890 1350 1550 940 1010 1420 1040 1480 1700 1060 1170 1570 1200 1620 1870 730 750 1120 770 1170 1350 820 880 1230 900 1280 1470 920 1020 1360 1040 1410 1630 810 840 1260 870 1320 1530 910 980 1400 1010 1450 1700 1020 1150 1540 1170 1600 1830 700 730 1090 750 1140 1330 790 850 1210 880 1260 1470 890 1000 1340 1020 1390 1590 STEEL FINNED TUBING 1" DIA. STEEL 1S-4¼ X 4¼-32 1S-4¼ X 4¼-40 1S-4¼ X 4¼-48 11⁄4" DIA. STEEL 1¼S-4¼ X 4¼-32 1¼S-4¼ X 4¼-40 1¼S-4¼ X 4¼-48 1" DIA. STEEL 2S-4¼ X 4¼-32 2S-4¼ X 4¼-40 2S-4¼ X 4¼-48 22 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.70 5.90 8.80 6.10 9.20 10.60 6.40 6.90 9.70 7.10 10.10 11.60 7.20 8.00 10.70 8.20 11.10 12.80 1370 1420 2110 1460 2210 2540 1540 1660 2330 1700 2420 2780 1730 1920 2570 1970 2660 3070 1070 1110 1650 1140 1720 1980 1200 1290 1820 1330 1890 2170 1350 1500 2000 1540 2070 2390 950 980 1460 1010 1520 1750 1060 1150 1610 1170 1670 1920 1190 1320 1770 1360 1840 2120 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.50 5.70 8.60 5.90 9.00 10.40 6.20 6.70 9.50 6.90 9.90 11.40 7.00 7.80 10.50 8.00 10.90 12.50 1320 1370 2060 1420 2160 2500 1490 1610 2290 1660 2380 2780 1680 1880 2520 1920 2620 3000 1030 1070 1610 1110 1680 1950 1160 1260 1790 1290 1860 2170 1310 1470 1970 1500 2040 2340 910 950 1420 980 1490 1730 1030 1110 1580 1150 1640 1920 1160 1300 1740 1320 1810 2070 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.60 5.80 8.70 6.00 9.10 10.50 6.30 6.80 9.60 7.00 10.00 11.50 7.10 7.90 10.60 8.10 11.00 12.70 1340 1390 2090 1440 2180 2520 1510 1630 2300 1680 2400 2760 1700 1900 2540 1940 2640 3050 1050 1080 1630 1120 1700 1970 1180 1270 1790 1310 1870 2150 1330 1480 1980 1510 2060 2380 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 21. 920 960 1440 990 1500 1740 1040 1120 1590 1160 1660 1900 1170 1310 1750 1340 1820 2100 820 850 1270 880 1330 1540 920 990 1400 1020 1460 1680 1040 1160 1550 1180 1610 1860 710 740 1110 760 1160 1340 800 860 1220 890 1270 1460 900 1010 1350 1030 1400 1620 GUARANTEED RATINGS FF5 STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 COPPER FINNED TUBING ¾C-2¾ X 4 -40 3 ⁄4" DIA. COPPER ¾C-2¾ X 4 -32 ¾C-2¾ X 4 -48 ¾C-3¼ X 3¼-40 3 ⁄4" DIA. COPPER ¾C-3¼ X 3¼-32 ¾C-3¼ X 3¼-48 ¾C-4¼ X 4¼-40 3 ⁄4" DIA. COPPER ¾C-4¼ X 4¼-32 ¾C-4¼ X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.43 4.68 6.93 4.90 7.65 8.77 5.14 5.61 7.56 5.89 8.22 9.43 5.56 6.41 8.91 6.88 9.52 10.62 1063 1122 1663 1175 1835 2105 1234 1346 1815 1412 1973 2264 1333 1538 2138 1650 2284 2548 829 875 1297 916 1431 1642 963 1050 1416 1102 1539 1766 1040 1199 1668 1287 1781 1987 733 774 1148 811 1266 1453 852 929 1252 975 1362 1562 920 1061 1475 1139 1576 1758 648 684 1015 717 1119 1284 753 821 1107 862 1204 1381 813 938 1304 1007 1393 1554 563 595 881 623 972 1116 654 714 962 749 1046 1200 707 815 1133 875 1210 1350 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.10 5.60 7.40 5.90 8.20 9.40 5.70 6.30 7.70 6.70 8.60 9.90 6.20 7.10 8.10 7.60 9.00 10.40 1220 1340 1480 1420 1970 2260 1370 1510 1850 1610 2060 2380 1490 1700 1940 1820 2160 2500 950 1050 1150 1110 1540 1760 1070 1180 1440 1260 1610 1860 1160 1330 1510 1420 1680 1950 840 920 1020 980 1360 1560 950 1040 1280 1110 1420 1640 1030 1170 1340 1260 1490 1730 740 820 900 870 1200 1380 840 920 1130 980 1260 1450 910 1040 1180 1110 1320 1530 650 710 780 750 1040 1200 730 800 980 850 1090 1260 790 900 1030 960 1140 1330 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 6.70 7.10 10.50 7.40 11.60 13.30 7.80 8.50 11.50 8.90 12.50 14.30 8.40 9.70 13.50 10.40 14.40 16.10 1610 1700 2520 1780 2780 3190 1870 2040 2750 2140 2990 3430 2020 2330 3240 2500 3460 3860 1260 1330 1970 1390 2170 2490 1460 1590 2150 1670 2330 2680 1580 1820 2530 1950 2700 3010 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 21. 1110 1170 1740 1230 1920 2200 1290 1410 1900 1480 2060 2370 1390 1610 2240 1730 2390 2660 980 1040 1540 1090 1700 1950 1140 1240 1680 1310 1820 2090 1230 1420 1980 1530 2110 2350 850 900 1340 940 1470 1690 990 1080 1460 1130 1580 1820 1070 1230 1720 1330 1830 2050 23 FF5 GUARANTEED RATINGS STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 813 865 1272 901 1411 1616 952 1040 1395 1086 1519 1740 1024 1174 1632 1261 1755 1951 940 1030 1370 1080 1510 1740 1050 1160 1420 1230 1590 1830 1140 1310 1500 1400 1670 1910 720 765 1125 797 1248 1430 842 920 1234 961 1343 1539 906 1038 1444 1116 1553 1726 830 910 1210 960 1340 1540 920 1030 1260 1090 1410 1620 1010 1160 1320 1240 1480 1690 636 676 994 705 1103 1264 745 813 1091 849 1188 1361 801 918 1276 986 1373 1526 730 810 1070 850 1180 1360 820 910 1110 960 1240 1430 890 1020 1170 1100 1310 1490 553 588 864 612 958 1098 647 707 948 738 1032 1182 696 798 1109 857 1193 1326 640 700 930 740 1030 1180 710 790 960 840 1080 1250 770 890 1020 950 1130 1300 COPPER FINNED TUBING 1" DIA. COPPER 1C-2¾ X 4-32 1C-2¾ X 4-40 1C-2¾ X 4-48 1" DIA. COPPER 1C-3¼ X 3¼-32 1C-3¼ X 3¼-40 1C-3¼ X 3¼-48 1" DIA. COPPER 1C-4¼ X 4¼ -32 1C-4¼ X 4¼-40 1C-4¼ X 4¼-48 24 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.35 4.62 6.79 4.81 7.54 8.64 5.09 5.56 7.45 5.80 8.11 9.30 5.47 6.27 8.72 6.74 9.38 10.42 5.00 5.50 7.30 5.80 8.10 9.30 5.60 6.20 7.60 6.60 8.50 9.80 6.10 7.00 8.00 7.50 8.90 10.20 6.60 7.00 10.30 7.30 11.40 13.10 7.70 8.40 11.30 8.80 12.30 14.10 8.30 9.50 13.20 10.20 14.20 15.80 1043 1109 1630 1155 1808 2072 1221 1333 1789 1393 1947 2231 1313 1505 2092 1617 2251 2501 1200 1320 1750 1390 1940 2230 1340 1490 1820 1580 2040 2350 1460 1680 1920 1800 2140 2450 1580 1680 2470 1750 2740 3140 1850 2020 2710 2110 2950 3380 1990 2280 3170 2450 3410 3790 1230 1310 1930 1370 2140 2450 1440 1580 2110 1650 2300 2640 1550 1780 2470 1910 2660 2960 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 21. 1090 1160 1700 1210 1890 2170 1280 1390 1870 1460 2040 2330 1370 1570 2190 1690 2350 2620 960 1020 1510 1070 1670 1920 1130 1230 1650 1290 1800 2060 1210 1390 1930 1490 2080 2310 840 890 1310 930 1450 1660 980 1070 1440 1120 1560 1790 1050 1210 1680 1300 1810 2010 GUARANTEED RATINGS FF5 STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 710 756 1102 788 1225 1398 829 897 1202 938 1312 1507 883 1016 1412 1093 1521 1694 628 668 974 696 1083 1236 733 793 1063 829 1159 1333 781 898 1248 966 1345 1498 546 581 847 605 941 1074 637 689 923 721 1007 1158 679 780 1084 840 1168 1301 1080 1150 1670 1190 1860 2120 1260 1360 1820 1420 1990 2280 1340 1540 2140 1660 2300 2570 950 1010 1480 1060 1640 1870 1110 1200 1610 1260 1760 2020 1180 1360 1890 1460 2040 2270 830 880 1280 920 1430 1630 960 1040 1400 1090 1530 1750 1030 1180 1640 1270 1770 1970 COPPER FINNED TUBING 11⁄4" DIA. COPPER 1¼C-2¾ X 4 -32 1¼C-2¾ X 4-40 1¼C-2¾ X 4-48 11⁄4" DIA. COPPER 1¼C-3¼ X 3¼-32 1¼C-3¼ X 3¼-40 1¼C-3¼ X 3¼-48 11⁄4" DIA. COPPER 1¼C-4¼ X 4¼-32 1¼C-4¼ X 4¼-40 1¼C-4¼ X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.29 4.57 6.66 4.76 7.40 8.44 5.01 5.42 7.26 5.67 7.92 9.10 5.34 6.13 8.53 6.60 9.19 10.23 1030 1096 1597 1142 1775 2026 1201 1300 1742 1360 1901 2185 1280 1472 2046 1584 2204 2455 803 855 1246 891 1385 1580 937 1014 1359 1060 1483 1704 999 1148 1596 1236 1719 1915 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 6.50 6.90 10.10 7.20 11.20 12.80 7.60 8.20 11.00 8.60 12.00 13.80 8.10 9.30 12.90 10.00 13.90 15.50 1560 1660 2420 1730 2690 3070 1820 1970 2640 2060 2880 3310 1940 2230 3100 2400 3340 3720 1220 1290 1890 1350 2100 2400 1420 1540 2060 1610 2250 2580 1510 1740 2420 1870 2610 2900 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.00 5.50 7.30 5.80 8.00 9.20 5.60 6.20 7.60 6.60 8.40 9.70 6.10 7.00 8.00 7.40 8.80 10.20 1200 1320 1750 1390 1920 2210 1340 1490 1820 1580 2020 2330 1460 1680 1920 1780 2110 2450 940 1030 1370 1080 1500 1720 1050 1160 1420 1230 1580 1820 1140 1310 1500 1390 1650 1910 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 21. 830 910 1210 960 1320 1520 920 1030 1260 1090 1390 1610 1010 1160 1320 1230 1460 1690 730 810 1070 850 1170 1350 870 910 1110 960 1230 1420 890 1020 1170 1090 1290 1490 640 700 930 740 1020 1170 710 790 960 840 1070 1230 770 890 1020 940 1120 1300 25 GUARANTEED RATINGS FF3 In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) LOW PROFILE STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 590 620 640 880 640 710 730 990 730 790 830 1120 520 550 570 780 570 630 650 880 650 700 730 990 460 480 500 690 500 560 570 770 570 620 650 880 400 420 430 600 430 480 500 670 500 540 560 760 790 840 900 1230 860 940 990 1370 940 1030 1080 1480 700 750 790 1090 760 830 880 1210 830 910 960 1310 620 660 700 960 670 730 770 1070 730 810 850 1160 540 570 610 840 580 640 670 930 640 700 740 1010 STEEL FINNED TUBING 11⁄4" DIA. STEEL 1" DIA. STEEL 1S-3¼ X 3¼-32 1S-3¼ X 3¼-40 1S-3¼ X 3¼-48 1¼S-3¼ X 3¼-32 1¼S-3¼ X 3¼-40 1¼S-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 3.12 3.30 3.40 4.70 3.40 3.80 3.90 5.30 3.90 4.20 4.40 6.00 3.00 3.20 3.30 4.60 3.30 3.70 3.80 5.20 3.80 4.10 4.30 5.90 750 790 820 1130 820 910 940 1270 940 1010 1060 1440 720 770 790 1100 790 890 910 1250 910 980 1030 1420 560 600 620 860 620 690 710 980 710 760 800 1110 500 530 550 760 550 610 630 860 630 680 710 980 440 470 480 670 480 540 560 760 560 600 630 870 380 410 420 580 420 470 480 660 480 520 550 750 3 ⁄4" DIA. COPPER 3 ⁄4" DIA. COPPER COPPER FINNED TUBING ¾C-2 ⁄4 X 4-32 3 ¾C-2¾ X 4-40 ¾C-2¾ X 4-48 ¾C-3¼ X 3¼-32 ¾C-3¼ X 3¼-40 ¾C-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 4.20 4.50 4.80 6.60 4.60 5.00 5.30 7.30 5.00 5.50 5.80 7.90 4.10 4.40 4.70 6.40 4.50 4.90 5.10 7.00 5.00 5.30 5.60 7.60 1010 1080 1150 1580 1110 1200 1270 1750 1200 1320 1390 1900 980 1060 1130 1540 1080 1180 1220 1680 1200 1270 1340 1820 760 830 880 1200 840 920 950 1310 940 990 1050 1420 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 21. 26 680 730 780 1060 750 810 840 1160 830 880 920 1260 600 650 690 940 660 720 740 1020 730 770 820 1110 520 560 600 820 570 630 650 890 640 670 710 960 FF3 GUARANTEED RATINGS LOW PROFILE In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 600 650 690 950 660 720 760 1060 720 790 840 1140 520 560 600 830 570 630 660 920 630 690 730 990 11⁄4" DIA. COPPER 1" DIA. COPPER 1" DIA. COPPER 1" DIA. COPPER COPPER FINNED TUBING 1C-2¾ X 4-32 1C-2¾ X 4-40 1C-2¾ X 4-48 1C-3¼ X 3¼-32 1C-3¼ X 3¼-40 1C-3¼ X 3¼-48 1¼C-2¾ X 4-32 1¼C-2¾ X 4-40 1¼C-2¾ X 4-48 1¼C-3¼ X 3¼-32 1¼C-3¼ X 3¼-40 1¼C-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 4.10 4.40 4.70 6.50 4.50 4.90 5.20 7.20 4.90 5.40 5.70 7.80 980 1060 1130 1560 1080 1180 1250 1730 1180 1300 1370 1870 760 830 880 1220 840 920 980 1350 920 1010 1070 1460 680 730 780 1080 750 810 860 1190 810 900 950 1290 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 4.00 4.30 4.60 6.40 4.40 4.80 5.10 7.10 4.80 5.30 5.60 7.70 960 1030 1110 1540 1060 1150 1220 1700 1150 1270 1340 1850 750 800 860 1200 830 900 950 1330 900 990 1050 1440 660 710 760 1060 730 790 840 1170 790 880 920 1280 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 4.00 4.30 4.60 6.30 4.40 4.80 5.00 6.90 4.90 5.20 5.50 7.50 3.50 3.80 4.00 5.50 4.40 4.70 5.00 6.90 4.80 5.10 5.40 7.40 960 1030 1100 1510 1060 1150 1200 1660 1180 1250 1320 1800 840 910 960 1320 1060 1130 1200 1660 1150 1220 1300 1780 750 800 860 1180 830 900 940 1290 920 980 1030 1400 660 710 750 1030 830 880 940 1290 900 950 1010 1390 660 710 760 1040 730 790 830 1150 810 860 910 1240 580 630 660 910 730 780 830 1150 790 840 900 1230 590 630 670 920 650 700 730 1010 720 760 810 1100 590 630 670 940 650 700 740 1040 700 770 820 1130 510 560 590 810 650 690 730 1010 700 740 790 1090 510 550 580 800 560 610 640 880 630 660 700 950 510 550 580 820 560 610 650 900 610 670 710 980 450 480 510 700 560 600 640 880 610 650 690 940 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 21. 27 FR5/FR3 ENCLOSURE ROUNDED GRILLE ENCLOSURES BRACKET APPLICATION: When high heat output is demanded into room and along exterior walls. Appealing enclosure design allows heat to radiate through louvers rounded along top and front edge of cabinet. TINNERMAN NUT ENCLOSURE: • 14 to 18-gauge primed, phosphatized CRS. • 1-foot to 8-foot lengths in 6-inch increments. • Powder coated finish in decorator colors • available. • Aluminum or stainless steel available. ELEMENT: • Steel or copper/aluminum. • 1-foot to 12-foot lengths in 6-inch •increments. (10-foot maximum length • for steel.) • Galvanized fins .032 inches thick, • aluminum fins .016 inches thick. FIN ENCLOSURE MOUNTING CHANNEL DETAIL POSITIVE LOCKING BOTTOM MOUNTING CLIP DETAIL Cutaway view of FR5 enclosure showing 4 1⁄4" x 4 1⁄4" fin configuration. SECTION "X - X" INTERNAL JOGGLE-JOINER MOUNTING: • Mounting channel • Full back panel 20-gauge (18-gauge available) galvannealed steel. • Urethane gasket for air seal available. HANGERS: • Self-gauging, snap fit, expansion cradle • • with positive-locking, bottom-mounting • clip provides easy installation as well • as security. • 16-gauge galvannealed steel. • Slide cradle will accommodate 13⁄4 -inch •linear expansion for quiet operation. JOINTS: • Internal joggle joiners provide hairline •joints without any external fasteners. DAMPER: • (Optional) Durable knob or security • tamper proof available. OPTIONAL LOUVERED INLETS: • Horizontal bottom inlet louvers -FRHL • Vertical louvered inlet-FRVL *CENTERLINES ARE BASED ON 1" COPPER TUBE *CENTERLINES ARE BASED ON 1" COPPER TUBE DAMPER OPTION IS DEPENDENT ON ENCLOSURE SIZE & PIPING CONFIGURATIONS. FR5 PIPE SIZE STEEL COPPER 28 FRVL5 FIN SIZE A B ⁄4", 1", 11⁄4" 23⁄4" X 4" 14" N/A 3 1 1", 1 ⁄4" ⁄4", 1", 11⁄4" 31⁄4" X 31⁄4" 20" 53⁄8" 1", 11⁄4", 2 3⁄4", 1", 11⁄4" 41⁄4" X 41⁄4" 24" 3 FRHL5 FR3 PIPE SIZE STEEL COPPER N/A 1", 11⁄4" FIN SIZE A B 3 ⁄4", 1", 11⁄4" 23⁄4" X 4" 8" 15 11" 3 ⁄16" 3 ⁄4", 1", 11⁄4" 31⁄4" X 31⁄4" 14" FR5 GUARANTEED RATINGS STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F Rows Of Finned Tube (On 6-inch Centers) FINNED TUBE MODEL Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 770 790 1180 830 1230 1440 860 920 1290 950 1370 1580 950 1070 1440 1110 1500 1720 680 700 1040 730 1090 1280 760 810 1150 840 1210 1390 840 950 1280 980 1320 1520 600 620 920 650 960 1130 670 720 1010 740 1070 1230 740 840 1130 870 1170 1350 520 540 800 560 840 980 580 630 880 650 930 1070 650 730 980 750 1020 1170 STEEL FINNED TUBING 1" DIA. STEEL 1S-3¼X 3¼-32 1S-3¼ X 3¼-40 1S-3¼ X 3¼-48 11⁄4" DIA. STEEL 1¼S-3¼ X 3¼-32 1¼S-3¼ X 3¼-40 1¼S-3¼ X 3¼-48 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.10 4.20 6.30 4.40 6.60 7.70 4.60 4.90 6.90 5.10 7.30 8.40 5.10 5.70 7.70 5.90 8.00 9.20 4.00 4.10 6.20 4.30 6.50 7.50 4.50 4.80 6.80 5.00 7.10 8.20 5.00 5.60 7.50 5.80 7.80 9.00 980 1010 1510 1060 1580 1850 1100 1180 1660 1220 1750 2020 1220 1370 1850 1420 1920 2210 960 980 1490 1030 1560 1800 1080 1150 1630 1200 1700 1970 1200 1340 1800 1390 1870 2160 750 760 1160 800 1220 1400 840 900 1270 940 1330 1540 940 1050 1400 1080 1460 1680 660 680 1030 710 1080 1240 750 790 1120 830 1170 1360 830 920 1240 960 1290 1490 590 600 910 630 950 1100 660 700 990 730 1040 1200 730 820 1100 850 1140 1320 510 520 790 550 830 950 570 610 860 640 900 1040 640 710 950 740 990 1140 IMPORTANT RATING INFORMATION Guaranteed ratings based on: • Installation at height shown. (Lower heights are not recommended; for greater heights, refer to Table 1 on page 52.) • Entering air temperature of 65°F. (For other temperatures, refer to Table 2 or Table 3 on page 52.) • Steam at nominal 1 (actual 0.9) psig and 215°F. (For other conditions, refer to Table 2 on page 52.) • Water average temperature (°F) shown and velocity of 3 fps or more. (For lower velocities, see Figure 1 on page 53.) • The interrelationships of water velocities, flow rates, pressure drops, and temperature drops with respect to total Btu requirements for various tube diameters appear in Figure 1 on page 53. • Linear expansion of steel and copper finned tube with temperature is shown in Figure 4 on page 54. 29 FR5 GUARANTEED RATINGS STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 980 1010 1520 1040 1590 1820 1090 1170 1670 1230 1740 1990 1240 1390 1840 1420 1900 2200 870 890 1350 920 1400 1610 960 1040 1480 1090 1540 1760 1100 1230 1620 1260 1680 1950 750 770 1170 800 1220 1400 840 900 1280 940 1340 1530 950 1070 1410 1090 1460 1690 850 880 1280 910 1330 1540 950 1010 1390 1060 1460 1680 1070 1160 1490 1230 1580 1820 740 760 1120 790 1160 1340 830 880 1210 920 1270 1460 930 1010 1300 1070 1370 1580 STEEL FINNED TUBING 1" DIA. STEEL 1S-4¼ X 4¼-32 1S-4¼ X 4¼-40 1S-4¼ X 4¼-48 11⁄4" DIA. STEEL 1¼S-4¼ X 4¼-32 1¼S-4¼ X 4¼-40 1¼S-4¼ X 4¼-48 2" DIA. STEEL 2S-4¼ X 4¼-32 2S-4¼ X 4¼-40 2S-4¼ X 4¼-48 30 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.90 6.10 9.20 6.30 9.60 11.00 6.60 7.10 10.10 7.40 10.50 12.00 7.50 8.40 11.10 8.60 11.50 13.30 1420 1460 2210 1510 2300 2640 1580 1700 2420 1780 2520 2880 1800 2020 2660 2060 2760 3190 1110 1140 1720 1180 1790 2060 1230 1330 1890 1390 1970 2250 1400 1580 2070 1610 2150 2490 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.80 6.00 8.80 6.20 9.10 10.50 6.50 6.90 9.50 7.20 10.00 11.50 7.30 7.90 10.20 8.40 10.80 12.40 1390 1440 2110 1490 2180 2520 1560 1660 2280 1730 2400 2760 1750 1900 2450 2020 2590 2980 1080 1120 1650 1160 1700 1970 1220 1290 1790 1350 1870 2150 1370 1480 1910 1580 2020 2320 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 5.80 6.00 9.00 6.20 9.40 10.80 6.50 7.00 9.90 7.20 10.30 11.80 7.30 8.20 10.90 8.40 11.30 13.00 1390 1440 2160 1490 2260 2590 1560 1680 2380 1730 2470 2830 1750 1970 2620 2020 2710 3120 1080 1120 1680 1160 1760 2020 1220 1310 1860 1350 1930 2210 1370 1540 2040 1580 2110 2430 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 29. 960 990 1490 1030 1560 1790 1080 1160 1640 1190 1700 1950 1210 1360 1810 1390 1870 2150 960 990 1460 1030 1500 1740 1080 1150 1570 1190 1660 1900 1210 1310 1690 1390 1790 2060 850 880 1320 910 1380 1580 950 1020 1450 1060 1510 1730 1070 1200 1600 1230 1660 1900 740 760 1140 790 1200 1370 830 890 1260 920 1310 1500 930 1040 1390 1070 1440 1650 FR5 GUARANTEED RATINGS STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 855 901 1349 952 1483 1704 1014 1102 1431 1148 1555 1781 1086 1236 1472 1333 1606 1843 756 797 1193 842 1312 1507 897 975 1266 1016 1375 1576 961 1093 1302 1179 1421 1630 668 705 1055 745 1159 1333 793 862 1119 898 1216 1393 849 966 1151 1043 1256 1441 581 612 916 647 1007 1158 689 749 972 780 1056 1210 738 840 1000 906 1091 1252 1150 1210 1810 1280 1990 2280 1360 1480 1920 1540 2080 2390 1460 1660 1970 1790 2150 2470 1010 1070 1600 1130 1760 2020 1200 1310 1700 1360 1840 2110 1290 1460 1740 1580 1900 2180 COPPER FINNED TUBING ¾C-2¾ X 4-40 3 ⁄4" DIA. COPPER ¾C-2¾ X 4-32 ¾C-2¾ X 4-48 ¾C-3¼ X 3¼-40 3 ⁄4" DIA. COPPER ¾C-3¼ X 3¼-32 ¾C-3¼ X 3¼-48 ¾C-4¼ X 4¼-40 3 ⁄4" DIA. COPPER ¾C-4¼ X 4¼-32 ¾C-4¼ X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.57 4.81 7.21 5.09 7.92 9.10 5.42 5.89 7.65 6.13 8.31 9.52 5.80 6.60 7.87 7.12 8.58 9.85 5.30 5.80 8.10 6.10 9.00 10.30 5.90 6.50 9.40 6.90 9.70 10.70 6.40 7.40 9.70 7.90 10.00 11.00 6.90 7.30 10.90 7.70 12.00 13.80 8.20 8.90 11.60 9.30 12.60 14.40 8.80 10.00 11.90 10.80 13.00 14.90 1096 1155 1729 1221 1901 2185 1300 1412 1835 1472 1993 2284 1393 1584 1888 1709 2059 2363 1270 1390 1940 1460 2160 2470 1420 1560 2260 1660 2330 2570 1540 1780 2330 1900 2400 2640 1660 1750 2620 1850 2880 3310 1970 2140 2780 2230 3020 3460 2110 2400 2860 2590 3120 3580 990 1080 1510 1140 1680 1930 1110 1220 1760 1290 1820 2000 1200 1390 1820 1480 1870 2060 1290 1370 2040 1440 2250 2580 1540 1670 2170 1740 2360 2700 1650 1870 2230 2020 2430 2790 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 29. 880 960 1340 1010 1490 1700 980 1080 1560 1150 1610 1770 1060 1230 1610 1310 1660 1820 770 850 1180 890 1320 1510 870 950 1380 1010 1420 1570 940 1090 1420 1160 1460 1610 670 740 1030 770 1140 1310 750 830 1200 880 1230 1360 820 940 1230 1010 1270 1400 880 930 1390 980 1530 1750 1040 1130 1470 1180 1600 1830 1120 1270 1520 1370 1650 1900 31 FR5 GUARANTEED RATINGS STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 COPPER FINNED TUBING 1" DIA. COPPER 1C-2¾ X 4 -32 1C-2¾ X 4 -40 1C-2¾ X 4 -48 1" DIA. COPPER 1C-3¼ X 3¼-32 1C-3¼ X 3¼-40 1C-3¼ X 3¼-48 1" DIA. COPPER 1C-4¼ X 4¼-32 1C-4¼ X 4¼-40 1C-4¼ X 4¼-48 32 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.48 4.76 7.07 4.95 7.78 8.91 5.28 5.75 7.54 6.00 8.20 9.30 5.67 6.46 7.73 6.99 8.39 9.63 1076 1142 1696 1188 1868 2138 1267 1379 1808 1439 1967 2231 1360 1551 1855 1676 2013 2310 839 891 1323 927 1457 1668 988 1076 1411 1122 1534 1740 1060 1210 1447 1308 1570 1802 742 788 1170 820 1289 1475 874 952 1248 993 1357 1539 938 1070 1280 1157 1389 1594 656 696 1035 725 1139 1304 773 841 1103 878 1200 1361 829 946 1131 1023 1228 1409 570 605 899 630 990 1133 672 731 958 763 1042 1182 721 822 983 888 1067 1224 5.20 5.70 7.90 6.00 8.80 10.10 5.80 6.40 9.20 6.80 9.50 10.60 6.30 7.20 9.50 7.70 9.80 10.80 1250 1370 1900 1440 2110 2420 1390 1540 2210 1630 2280 2540 1510 1730 2280 1850 2350 2590 980 1070 1480 1120 1650 1890 1080 1200 1720 1270 1780 1980 1180 1350 1780 1440 1830 2020 860 950 1310 990 1460 1670 960 1060 1520 1120 1570 1750 1040 1190 1570 1280 1620 1790 760 840 1160 880 1290 1480 850 940 1350 990 1390 1550 920 1060 1390 1130 1430 1580 660 730 1010 760 1120 1280 740 820 1170 860 1210 1350 800 920 1210 980 1250 1370 6.80 7.20 10.70 7.50 11.80 13.50 8.00 8.70 11.40 9.10 12.40 14.10 8.60 9.80 11.70 10.60 12.70 14.60 1630 1730 2570 1800 2830 3240 1920 2090 2740 2180 2980 3380 2060 2350 2810 2540 3050 3500 1270 1350 2000 1400 2210 2530 1500 1630 2140 1700 2320 2640 1610 1830 2190 1980 2380 2730 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 29. 1120 1190 1770 1240 1950 2240 1320 1440 1890 1500 2060 2330 1420 1620 1940 1750 2100 2420 990 1060 1570 1100 1730 1980 1170 1270 1670 1330 1820 2060 1260 1430 1710 1550 1860 2140 860 920 1360 950 1500 1720 1020 1110 1450 1160 1580 1790 1090 1250 1490 1350 1620 1860 FR5 GUARANTEED RATINGS STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 829 875 1297 916 1431 1642 978 1060 1385 1112 1508 1719 1050 1199 1421 1287 1544 1781 733 774 1148 811 1266 1453 865 938 1225 984 1334 1521 929 1061 1257 1139 1366 1576 648 684 1015 717 1119 1284 765 829 1083 870 1180 1345 821 938 1111 1007 1208 1393 563 595 881 623 972 1116 665 721 941 756 1025 1168 714 815 965 875 1049 1210 1260 1330 1970 1390 2170 2490 1480 1610 2100 1680 2290 2610 1590 1820 2150 1950 2340 2700 1110 1170 1740 1230 1920 2200 1310 1420 1860 1490 2020 2300 1410 1610 1900 1720 2070 2390 980 1040 1540 1090 1700 1950 1160 1260 1640 1320 1790 2040 1240 1420 1680 1530 1830 2110 850 900 1340 940 1480 1690 1010 1090 1430 1140 1550 1770 1080 1230 1460 1330 1590 1830 COPPER FINNED TUBING 1¼" DIA. COPPER 1¼C-2¾ X 4-32 1¼C--2¾ X 4-40 1¼C--2¾ X 4-48 11⁄4" DIA. COPPER 1¼C-3¼ X 3¼-32 1¼C-3¼ X 3¼-40 1¼C-3¼ X 3¼-48 11⁄4" DIA. COPPER 1¼C-4¼ X 4¼-32 1¼C-4¼ X 4¼-40 1¼C-4¼ X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 14 20 20 24 24 24 14 20 20 24 24 24 14 20 20 24 24 24 18 24 24 28 28 28 18 24 24 28 28 28 18 24 24 28 28 28 4.43 4.68 6.93 4.90 7.65 8.77 5.23 5.67 7.40 5.94 8.06 9.19 5.61 6.41 7.59 6.88 8.25 9.52 4.80 5.50 7.70 5.80 8.60 9.90 5.70 6.20 9.00 6.50 9.30 10.40 6.10 7.10 9.30 7.60 9.60 10.70 6.70 7.10 10.50 7.40 11.60 13.30 7.90 8.60 11.20 9.00 12.20 13.90 8.50 9.70 11.50 10.40 12.50 14.40 1063 1122 1663 1175 1835 2105 1254 1360 1775 1426 1934 2204 1346 1538 1822 1650 1980 2284 1150 1320 1850 1390 2060 2380 1370 1490 2160 1560 2230 2500 1460 1700 2230 1820 2300 2570 1610 1700 2520 1780 2780 3190 1900 2060 2690 2160 2930 3340 2040 2330 2760 2500 3000 3460 900 1030 1440 1080 1610 1860 1070 1040 1680 1220 1740 1950 1140 1330 1740 1420 1790 2000 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 29. 790 910 1280 960 1420 1640 950 1030 1490 1080 1540 1720 1010 1170 1540 1260 1590 1770 700 810 1130 850 1260 1450 840 910 1320 950 1360 1530 890 1040 1360 1110 1400 1570 610 700 980 740 1090 1260 730 790 1140 830 1180 1330 770 900 1180 960 1220 1360 33 FR3 GUARANTEED RATINGS LOW PROFILE In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 620 660 690 940 670 730 760 1050 760 830 860 1180 550 580 610 830 590 650 680 920 680 730 760 1040 480 510 540 730 520 570 600 820 600 650 670 920 420 450 470 640 460 500 520 710 520 560 580 800 830 880 940 1270 900 980 1030 1400 980 1070 1120 1540 730 780 830 1120 790 860 910 1240 860 950 990 1360 650 690 730 990 700 760 810 1100 760 840 880 1200 560 600 640 860 610 660 700 950 660 730 760 1040 STEEL FINNED TUBING 11⁄4" DIA. STEEL 1" DIA. STEEL 1S-3¼ X 3¼-32 1S-3¼ X 3¼-40 1S-3¼ X 3¼-48 1¼S-3¼ X 3¼-32 1¼S-3¼ X 3¼-40 1¼S-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 3.30 3.50 3.70 5.00 3.60 3.90 4.10 5.60 4.10 4.40 4.60 6.30 3.20 3.40 3.60 4.90 3.50 3.80 4.00 5.50 4.00 4.30 4.50 6.20 790 840 890 1200 860 940 980 1340 980 1060 1100 1510 770 820 860 1180 840 910 960 1320 960 1030 1080 1490 600 640 670 920 660 710 750 1030 750 800 840 1160 530 570 590 810 580 630 660 910 660 710 750 1030 470 500 520 720 510 560 590 810 590 630 660 910 410 430 460 630 450 480 510 700 510 550 570 790 3 ⁄4" DIA. COPPER 3 ⁄4" DIA. COPPER COPPER FINNED TUBING ¾C-2¾ X 4-32 ¾C-2¾ X 4-40 ¾C-2¾ X 4-48 ¾C-3¼ X 3¼-32 ¾C-3¼ X 3¼-40 ¾C-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 4.40 4.70 5.00 6.80 4.80 5.20 5.50 7.50 5.20 5.70 6.00 8.20 4.20 4.50 4.70 6.40 4.50 4.90 5.20 7.10 5.00 5.40 5.70 7.90 1060 1130 1200 1630 1150 1250 1320 1800 1250 1370 1440 1970 1010 1080 1130 1540 1080 1180 1250 1700 1200 1300 1370 1900 790 840 880 1200 840 920 980 1330 940 1010 1070 1480 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 29. 34 700 750 780 1060 750 810 860 1170 830 900 950 1310 620 660 690 940 660 720 760 1040 730 790 840 1160 540 570 600 820 570 630 660 900 640 690 730 1010 FR3 GUARANTEED RATINGS LOW PROFILE In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 630 670 720 980 690 740 790 1090 740 820 870 1180 550 580 630 850 600 650 690 940 650 710 750 1030 600 650 690 940 670 720 760 1040 730 790 840 1140 520 560 600 820 580 630 660 900 640 690 730 990 11⁄4" DIA. COPPER 11⁄4" DIA. COPPER 1" DIA. COPPER 1" DIA. COPPER COPPER FINNED TUBING 1C-2¾ X 4-32 1C-2¾ X 4-40 1C-2¾ X 4-48 1C-3¼ X 3¼-32 1C-3¼ X 3¼-40 1C-3¼ X 3¼-48 1¼C-2¾ X 4-32 1¼C-2¾ X 4-40 1¼C-2¾ X 4-48 1¼C-3¼ X 3¼-32 1¼C-3¼ X 3¼-40 1¼C-3¼ X 3¼-48 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 4.30 4.60 4.90 6.70 4.70 5.10 5.40 7.40 5.10 5.60 5.90 8.10 1030 1100 1180 1610 1130 1220 1300 1780 1220 1340 1420 1940 800 860 920 1260 880 950 1010 1390 950 1050 1110 1510 710 760 810 1110 780 840 900 1230 840 920 980 1340 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 4.10 4.40 4.70 6.40 4.60 4.90 5.20 7.10 5.00 5.40 5.70 7.80 980 1060 1130 1540 1100 1180 1250 1700 1200 1300 1370 1870 760 830 880 1200 860 920 980 1330 940 1010 1070 1460 680 730 780 1060 760 810 860 1170 830 900 950 1290 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 8 11 14 14 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 12 15 18 18 4.10 4.40 4.70 6.40 4.50 4.90 5.20 7.10 5.00 5.40 5.70 7.80 3.60 3.90 4.10 5.60 4.50 4.80 5.10 7.00 4.90 5.30 5.60 7.70 980 1060 1130 1540 1080 1180 1250 1700 1200 1300 1370 1870 860 940 980 1340 1800 1150 1220 1680 1180 1270 1340 1850 760 830 880 1200 840 920 980 1330 940 1010 1070 1460 670 730 760 1050 840 900 950 1310 920 990 1050 1440 680 730 780 1060 750 810 860 1170 830 900 950 1290 590 650 680 920 750 790 840 1160 810 880 920 1280 600 650 690 940 660 720 760 1040 730 790 840 1140 520 570 600 820 660 700 740 1020 720 770 820 1130 520 560 600 820 570 630 660 900 640 690 730 990 460 500 520 710 570 610 650 890 630 670 710 980 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 29. 35 FSOS DOUBLE SLOPED GRILLE ENCLOSURES ENCLOSURE SNAP MOUNTING CHANNEL DETAIL APPLICATION: Double sloped panels provide required heat output when higher wall mounting is called for to restrict accessibility...such as in swimming pool areas and gymnasiums. ENCLOSURE ENCLOSURE: • 14 to 18-gauge primed, phosphatized CRS. • 1-foot to 8-foot lengths in 6-inch increments. • Powder coated finish in decorator colors • available. • Aluminum or stainless steel available. ELEMENT: • Steel or copper/aluminum. • 1-foot to 12-foot lengths in 6-inch •increments. (10-foot maximum length • for steel.) • Galvanized fins .032 inches thick, • aluminum fins .016 inches thick. FASTENERS (BY OTHERS) Cutaway view of FSOS enclosure showing 4 1⁄4" x 4 1⁄4" fin configuration. SECTION "X - X" "B" INTERNAL JOGGLE-JOINER DAMPER OPTIONAL MOUNTING: • Mounting channel • Full back panel 20-gauge (18-gauge available) galvannealed steel. • Urethane gasket for air seal available. HANGERS: • Wall mounted slip-in second row • brackets. • 16-gauge galvannealed steel. • Slide cradle will accommodate 13⁄4 -inch •linear expansion for quiet operation. "B" DAMPER OPTIONAL WALL "A" 6" JOINTS: • Internal joggle joiners provide hairline •joints without any external fasteners. "A" WALL * 6-1/8" DAMPER: • (Optional) Durable knob or security • tamper proof available. * 6-5/8" 3-15/64" 3-47/64" 1-31/32" 2-17/32" 4" MIN. 4" MIN. FLOOR FLOOR CENTERLINESARE AREBASED BASED ON TUBE **CENTERLINES ON1" 1"COPPER COPPER TUBE ARE BASED ON 1" COPPER TUBE * CENTERLINES *CENTERLINES ARE BASED ON 1" COPPER TUBE DAMPER OPTION IS DEPENDENT ON ENCLOSURE SIZE & PIPING CONFIGURATIONS. FSOS3 FSOS5 PIPE SIZE STEEL COPPER 36 FIN SIZE A B ¾", 1", 1¼" 2¾" X 4" N/A 18" 3 5⁄" 1", 1¼" ¾", 1", 1¼" 3¼" X 3¼" 24" 8 1", 1¼", 2 ¾", 1", 1¼" 4¼" X 4¼" PIPE SIZE STEEL COPPER N/A 1", 1¼" ¾", 1", 1¼" FIN SIZE 2¾" X 4" ¾", 1", 1¼" 3¼" X 3¼" A B 14" 315⁄16" FSOS5 STANDARD GUARANTEED RATINGS In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F Rows Of Finned Tube (On 6-inch Centers) FINNED TUBE MODEL Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 1S-3¼ X 3¼-32 1S-3¼ X 3¼-40 1S-3¼ X 3¼-48 1S-4¼ X 4¼-32 1S-4¼ X 4¼-40 11⁄4" DIA. STEEL 1¼S-3¼ X 3¼-32 11⁄4" DIA. STEEL 1S-4¼ X 4¼-48 1¼S-4¼ X 4¼-32 2" DIA. STEEL 1" DIA. STEEL 1" DIA. STEEL STEEL FINNED TUBING 2S-4¼ X 4¼-32 1¼S-3¼ X 3¼-40 1¼S-3¼ X 3¼-48 1¼S-4¼ X 4¼-40 1¼S-4¼ X 4¼-48 2S-4¼ X 4¼-40 2S-4¼ X 4¼-48 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. 1 1 2 1 1 2 1 1 2 18 24 24 18 24 24 18 24 24 22 28 28 22 28 28 22 28 28 1 1 2 1 1 2 1 1 2 18 24 24 18 24 24 18 24 24 22 28 28 22 28 28 22 28 28 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 3.82 4.39 6.65 4.18 4.90 7.31 4.60 5.39 8.04 917 1053 1595 1004 1176 1755 1104 1293 1930 716 821 1244 783 917 1369 861 1009 1506 633 727 1100 693 811 1211 762 892 1332 560 642 973 612 717 1070 673 789 1177 486 558 845 532 623 930 585 685 1023 3.75 4.30 6.51 4.10 4.80 7.17 4.51 5.28 7.88 899 1032 1564 984 1153 1720 1082 1268 1892 702 805 1220 768 899 1342 844 989 1476 621 712 1079 679 795 1187 747 875 1306 549 630 954 600 703 1049 660 773 1154 477 547 829 522 611 912 574 672 1003 22 28 28 22 28 28 22 28 28 5.10 5.85 8.86 5.58 6.53 9.75 6.13 7.19 10.72 22 28 28 22 28 28 22 28 28 5.00 5.74 8.69 5.47 6.40 9.56 6.01 7.04 10.51 22 28 28 22 28 28 22 28 28 4.91 5.69 8.27 5.40 6.26 9.10 5.94 6.89 10.01 1223 1404 2126 1338 1568 2340 1472 1724 2574 1199 1377 2085 1312 1537 2294 1443 1691 2523 1179 1366 1986 1297 1503 2184 1426 1653 2402 954 1095 1659 1044 1223 1825 1148 1345 2007 935 1074 1626 1023 1199 1789 1126 1319 1968 919 1066 1549 1011 1172 1704 1113 1289 1874 844 969 1467 923 1082 1614 1016 1190 1776 827 950 1438 905 1061 1583 996 1167 1741 813 943 1370 895 1037 1507 984 1141 1658 746 856 1297 816 956 1427 898 1052 1570 732 840 1272 800 938 1399 880 1031 1539 719 833 1211 791 917 1332 870 1008 1465 648 744 1127 709 831 1240 780 914 1364 636 730 1105 695 815 1216 765 896 1337 625 724 1052 687 796 1158 756 876 1273 IMPORTANT RATING INFORMATION Guaranteed ratings based on: • Installation at height shown. (Lower heights are not recommended; for greater heights, refer to Table 1 on page 52.) • Entering air temperature of 65°F. (For other temperatures, refer to Table 2 or Table 3 on page 52.) • Steam at nominal 1 (actual 0.9) psig and 215°F. (For other conditions, refer to Table 2 on page 52.) • Water average temperature (°F) shown and velocity of 3 fps or more. (For lower velocities, see Figure 1 on page 53.) • The interrelationships of water velocities, flow rates, pressure drops, and temperature drops with respect to total Btu requirements for various tube diameters appear in Figure 1 on page 53. • Linear expansion of steel and copper finned tube with temperature is shown in Figure 4 on page 54. 37 FSOS5 STANDARD GUARANTEED RATINGS In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 1016 1076 1597 1201 1313 1709 1300 1472 1756 793 839 1246 937 1024 1333 1014 1148 1369 701 742 1102 829 906 1179 897 1016 1211 620 656 974 733 801 1043 793 898 1071 539 570 847 637 696 906 689 780 930 1540 1630 2420 1820 1990 2590 1970 2230 2660 1201 1271 1888 1420 1552 2020 1537 1739 2075 1063 1125 1670 1256 1373 1787 1359 1539 1835 939 994 1476 1110 1214 1580 1202 1360 1623 ¾" DIA. COPPER ¾" DIA. COPPER COPPER FINNED TUBING ¾C-2¾ X 4-32 ¾C-2¾ X 4-40 ¾C-2¾ X 4-48 ¾C-3¼ X 3¼-32 ¾C-3¼ X 3¼-40 ¾" DIA. COPPER 1" DIA. COPPER 1C-2¾ X 4-32 1C-3¼ X 3¼-32 1" DIA. COPPER ¾C-4¼ X 4¼-32 1" DIA. COPPER ¾C-3¼ X 3¼-48 ¾C-4¼ X 4¼-40 ¾C-4¼ X 4¼-48 1C-2¾ X 4-40 1C-2¾ X 4-48 1C-3¼ X 3¼-40 1C-3¼ X 3¼-48 1C-4¼ X 4¼-32 1C-4¼ X 4¼-40 1C-4¼ X 4¼-48 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 18 24 24 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 22 28 28 4.24 4.48 6.66 5.01 5.47 7.12 5.42 6.13 7.32 4.81 5.09 7.56 5.69 6.22 8.09 6.16 6.97 8.31 6.40 6.80 10.10 7.60 8.30 10.80 8.20 9.30 11.10 4.15 4.43 6.60 4.90 5.34 6.99 5.28 6.00 7.21 4.72 5.03 7.50 5.56 6.06 7.94 6.00 6.81 8.19 6.30 6.70 10.00 7.40 8.10 10.60 8.00 9.10 10.90 1155 1223 1815 1365 1493 1943 1478 1673 1995 997 1063 1584 1175 1280 1676 1267 1439 1729 1133 1208 1800 1335 1455 1905 1440 1635 1965 1510 1610 2400 1780 1940 2540 1920 2180 2620 901 954 1416 1065 1164 1515 1152 1305 1556 777 829 1236 916 999 1308 988 1122 1349 883 942 1404 1041 1135 1486 1123 1275 1533 1178 1256 1872 1388 1513 1981 1498 1700 2044 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. 38 For important ratings information regarding above charts, see page 37. 797 844 1252 942 1030 1340 1019 1154 1377 688 733 1093 811 883 1157 874 993 1193 781 833 1242 921 1004 1314 994 1128 1356 1042 1111 1656 1228 1339 1753 1325 1504 1808 705 746 1107 833 910 1185 901 1020 1217 612 648 962 723 791 1030 783 886 1057 608 648 966 717 781 1023 773 878 1055 528 563 840 623 679 888 672 763 916 691 737 1098 814 888 1162 878 997 1199 921 982 1464 1086 1183 1549 1171 1330 1598 816 864 1283 965 1055 1373 1044 1182 1410 600 640 954 708 771 1010 763 867 1041 800 853 1272 943 1028 1346 1018 1155 1389 FSOS5 STANDARD GUARANTEED RATINGS In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 521 553 822 612 672 875 665 756 899 1¼" DIA. COPPER 1¼" DIA. COPPER 1¼" DIA. COPPER COPPER FINNED TUBING 1¼C-2¾ X 4-32 1¼C-2¾ X 4-40 1¼C-2¾ X 4-48 1¼-3¼ X 3¼-32 1¼-3¼ X 3¼-40 1¼-3¼ X 3¼-48 1¼-4¼ X 4¼-32 1¼-4¼ X 4¼-40 1¼-4¼ X 4¼-48 1 1 2 1 1 2 1 1 2 18 24 24 18 24 24 18 24 24 22 28 28 22 28 28 22 28 28 4.10 4.35 6.46 4.81 5.28 6.88 5.23 5.94 7.07 983 1043 1551 1155 1267 1650 1254 1426 1696 767 813 1210 901 988 1287 978 1112 1323 679 720 1070 797 874 1139 865 984 1170 600 636 946 705 773 1007 765 870 1035 1 1 2 1 1 2 1 1 2 18 24 24 18 24 24 18 24 24 22 28 28 22 28 28 22 28 28 6.20 6.60 9.80 7.20 8.00 10.40 7.90 9.00 10.70 1490 1580 2350 1750 1920 2500 1900 2160 2570 1162 1232 1833 1365 1498 1950 1482 1685 2005 1028 1090 1622 1208 1325 1725 1311 1490 1773 909 964 1434 1068 1171 1525 1159 1318 1568 1 1 2 1 1 2 1 1 2 18 24 24 18 24 24 18 24 24 22 28 28 22 28 28 22 28 28 4.66 4.94 7.34 5.47 6.00 7.81 5.94 6.75 8.03 1118 1185 1763 1313 1440 1875 1425 1620 1928 872 924 1375 1024 1123 1463 1112 1264 1503 771 818 1216 906 994 1294 983 1118 1330 682 723 1075 801 878 1144 869 988 1176 592 628 934 696 763 994 755 859 1022 790 837 1246 928 1018 1325 1007 1145 1362 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 37. 39 FSOS3 STANDARD GUARANTEED RATINGS In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 1¼" DIA. STEEL 1" DIA. STEEL STEEL FINNED TUBING 1S-3¼ X 3¼-32 1 14 18 3.44 826 644 570 504 438 1S-3¼ X 3¼-40 1 14 18 3.76 903 705 623 551 479 1S-3¼ X 3¼-48 1 14 18 4.14 994 775 686 606 527 1¼-3¼ X 3¼-32 1 14 18 3.37 809 631 559 494 429 1¼-3¼ X 3¼-40 1 14 18 3.69 886 691 611 540 469 1¼-3¼ X 3¼-48 1 14 18 4.06 974 760 672 594 516 1" DIA. COPPER 1" DIA. COPPER ¾" DIA. COPPER ¾" DIA. COPPER COPPER FINNED TUBING 40 ¾C-2¾ X 4-32 1 14 18 3.52 844 658 582 515 447 ¾C-2¾ X 4-40 1 14 18 4.15 997 778 688 608 528 ¾C-2¾ X 4-48 1 14 18 4.50 1079 842 745 658 572 ¾C-3¼ X 3¼-32 1 14 18 3.99 959 748 661 585 508 ¾C-3¼ X 3¼-40 1 14 18 4.72 1133 884 782 691 600 ¾C-3¼ X 3¼-48 1 14 18 5.11 1226 957 846 748 650 1C-2¾ X 4-32 1 14 18 3.45 827 645 571 642 433 1C-2¾ X 4-40 1 14 18 4.06 975 761 673 498 508 1C-2¾ X 4-48 1 14 18 4.38 1052 820 726 585 552 1C-3¼ X 3¼-32 1 14 18 3.73 895 698 617 546 474 1C-3¼ X 3¼-40 1 14 18 4.62 1108 864 765 676 587 1C-3¼ X 3¼-48 1 14 18 4.74 1138 887 785 694 603 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 37. GUARANTEED RATINGS FSOS3 STANDARD In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 1¼" DIA. COPPER 1¼" DIA. COPPER COPPER FINNED TUBING 1¼C-2¾ X 4-32 1 14 18 3.40 816 637 563 498 433 1¼C-2¾ X 4-40 1 14 18 3.99 959 748 661 585 508 1¼C-2¾ X 4-48 1 14 18 4.34 1041 812 718 635 552 1¼C-3¼ X 3¼-32 1 14 18 3.86 928 723 640 566 492 1¼C-3¼ X 3¼-40 1 14 18 4.54 1089 850 752 665 577 1¼C-3¼ X 3¼-48 1 14 18 4.93 1183 923 816 721 627 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 37. 41 S-SL ENCLOSURE SECURITY SLOPED GRILLE ENCLOSURES APPLICATION: Meet interior design specifications requiring consistent and even heat through conventional louvers and when security of enclosure is imperative. FASTENERS (BY OTHERS) ENCLOSURE: • 14 to 18-gauge primed, phosphatized CRS. • 1-foot to 8-foot lengths in 6-inch increments. • Powder coated finish in decorator colors • available. • Stainless steel available. OFFSET MOUNTING CHANNEL DETAIL ELEMENT: • Steel or copper/aluminum. • 1-foot to 12-foot lengths in 6-inch •increments. (10-foot maximum length • for steel.) • Galvanized fins .032 inches thick, • aluminum fins .016 inches thick. MOUNTING: • Mounting channel • Offset full back panel 20-gauge (18-gauge available) galvannealed steel. • Urethane gasket for air seal available. ENCLOSURE Cutaway view of S-SL enclosure showing 4 1⁄4" x 4 1⁄4" fin configuration. TAMPER PROOF FASTENERS (BY OTHERS) "B" HANGERS: • Wall mounted slip-in 2nd row brackets. • 16-gauge galvannealed steel. • Slide cradle will accommodate 13⁄4 -inch •linear expansion for quiet operation. DAMPER OPTIONAL BOTTOM FLANGE JOINTS: • Internal joggle joiners provide hairline •joints without any external fasteners. DAMPER: • (Optional) Durable knob or security • tamper proof available. 6" "A" WALL SECTION "X - X" INTERNAL JOGGLE-JOINER 6" * 3-3/4" 55/64" S-SL 4" MIN. 2-17/32" FLOOR CENTERLINES ARE ARE BASED COPPER TUBE **CENTERLINES BASEDON ON1"1" COPPER TUBE 42 DAMPER OPTION IS DEPENDENT ON ENCLOSURE SIZE & PIPING CONFIGURATIONS. PIPE SIZE STEEL COPPER FIN SIZE A B 1", 1¼" ¾", 1", 1¼" 3¼" X 3¼" 12" ¾", 1", 1¼" 2¾" X 4" 18" 53⁄8" N/A 1", 1¼", 2 ¾", 1", 1¼" 4¼" X 4¼" 24" S-SL STANDARD GUARANTEED RATINGS In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 STEEL FINNED TUBING 1" DIA. STEEL 1S-3¼ X 3¼-32 1S-3¼ X 3¼-40 1S-3¼ X 3¼-48 1" DIA. STEEL 1S-4¼ X 4¼-32 1S-4¼ X 4¼-40 1S-4¼ X 4¼-48 1¼" DIA. STEEL 1¼S-3¼ X 3¼-32 1¼S-3¼ X 3¼-40 1¼S-3¼ X 3¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 3.63 3.77 5.67 3.96 6.00 6.93 4.02 4.35 6.22 4.62 6.60 7.54 4.62 5.14 6.79 5.42 7.21 8.31 5.50 5.71 8.58 6.00 9.08 10.50 6.08 6.58 9.42 7.00 10.00 11.42 7.00 7.79 10.29 8.21 10.92 12.58 871 904 1360 950 1439 1663 964 1043 1492 1109 1584 1808 1109 1234 1630 1300 1729 1993 680 705 1060 741 1122 1297 752 813 1163 865 1236 1411 865 963 1272 1014 1349 1555 601 624 938 656 993 1148 665 720 1029 765 1093 1248 765 852 1125 897 1193 1375 531 552 829 580 878 1015 588 636 910 676 966 1103 676 753 994 793 1055 1216 462 479 721 504 763 881 511 553 791 588 840 958 588 654 864 689 916 1056 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 3.71 3.79 5.79 4.08 6.21 7.08 4.21 4.50 6.29 4.79 6.79 7.79 4.71 5.21 7.00 5.50 7.42 8.58 890 910 1390 980 1490 1700 1010 1080 1510 1150 1630 1870 1130 1250 1680 1320 1780 2060 694 710 1084 764 1162 1326 788 842 1178 897 1271 1459 881 975 1310 1030 1388 1607 614 628 959 676 1028 1173 697 745 1042 794 1125 1290 780 863 1159 911 1228 1421 543 555 848 598 909 1037 616 659 921 702 994 1141 689 763 1025 805 1086 1257 472 482 737 519 790 901 535 572 800 610 864 991 599 663 890 700 943 1092 1320 1370 2060 1440 2180 2520 1460 1580 2260 1680 2400 2740 1680 1870 2470 1970 2620 3020 1030 1069 1607 1123 1700 1966 1139 1232 1763 1310 1872 2137 1310 1459 1927 1537 2044 2356 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 37. 911 945 1421 994 1504 1739 1007 1090 1559 1159 1656 1891 1159 1290 1704 1359 1808 2084 805 836 1257 878 1330 1537 891 964 1379 1025 1464 1671 1025 1141 1507 1202 1598 1842 700 726 1092 763 1155 1336 774 837 1198 890 1272 1452 890 991 1309 1044 1389 1601 43 S-SL STANDARD GUARANTEED RATINGS In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 1300 1340 2020 1420 2140 2470 1460 1560 2210 1630 2350 2690 1630 1820 2420 1920 2570 2980 1014 1045 1576 1108 1669 1927 1139 1217 1724 1271 1833 2098 1271 1420 1888 1498 2005 2324 897 925 1394 980 1477 1704 1007 1076 1525 1125 1622 1856 1125 1256 1670 1325 1773 2056 793 817 1232 866 1305 1507 891 952 1348 994 1434 1641 994 1110 1476 1171 1568 1818 689 710 1071 753 1134 1309 774 827 1171 864 1246 1426 864 965 1283 1018 1362 1579 1281 1320 1990 1399 2108 2433 1438 1537 2177 1606 2315 2650 1606 1793 2384 1891 2531 2935 999 1030 1552 1091 1644 1898 1122 1199 1698 1252 1806 2067 1252 1398 1859 1475 1975 2290 884 911 1373 965 1454 1679 992 1060 1502 1108 1597 1828 1108 1237 1645 1305 1747 2025 781 805 1214 853 1286 1484 877 937 1328 979 1412 1616 979 1094 1454 1154 1544 1791 679 700 1055 741 1117 1289 762 814 1154 851 1227 1404 851 950 1263 1002 1342 1556 STEEL FINNED TUBING 1¼" DIA. STEEL 1¼S-4¼ X 4¼-32 1¼S-4¼ X 4¼-40 1¼S-4¼ X 4¼-48 2" DIA. STEEL 2S-4¼ X 4¼-32 2S-4¼ X 4¼-40 2S-4¼ X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 5.42 5.58 8.42 5.92 8.92 10.29 6.08 6.50 9.21 6.79 9.79 11.21 6.79 7.58 10.08 8.00 10.71 12.42 5.34 5.50 8.29 5.83 8.78 10.14 5.99 6.40 9.07 6.69 9.64 11.04 6.69 7.47 9.93 7.88 10.55 12.23 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 37. 44 S-SL STANDARD GUARANTEED RATINGS In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 539 570 847 612 958 1098 637 696 906 738 1007 1151 689 780 930 864 1042 1193 COPPER FINNED TUBING ¾" DIA. COPPER ¾C-2¾ X 4-32 ¾C-2¾ X 4-40 ¾C-2¾ X 4-48 ¾" DIA. COPPER ¾C-3¼ X 3¼-32 ¾C-3¼ X 3¼-40 ¾C-3¼ X 3¼-48 ¾" DIA. COPPER ¾C-4¼ X 4¼-32 ¾C-4¼ X 4¼-40 ¾C-4¼ X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 4.24 4.48 6.66 4.81 7.54 8.64 5.01 5.47 7.12 5.80 7.92 9.05 5.42 6.13 7.32 6.79 8.20 9.38 1016 1076 1597 1155 1808 2072 1201 1313 1709 1393 1901 2171 1300 1472 1756 1630 1967 2251 793 839 1246 901 1411 1616 937 1024 1333 1086 1483 1694 1014 1148 1369 1272 1534 1755 701 742 1102 797 1248 1430 829 906 1179 961 1312 1498 897 1016 1211 1125 1357 1553 620 656 974 705 1103 1264 733 801 1043 849 1159 1325 793 898 1071 994 1200 1373 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 4.92 5.42 7.50 5.79 8.58 9.79 5.50 6.08 8.79 6.58 9.21 10.21 6.00 6.92 9.00 7.50 9.50 10.50 1180 1300 1800 1390 2060 2350 1320 1460 2110 1580 2210 2450 1440 1660 2160 1800 2280 2520 920 1014 1404 1084 1607 1833 1030 1139 1646 1232 1724 1911 1123 1295 1685 1404 1778 1966 814 897 1242 959 1421 1622 911 1007 1456 1090 1525 1691 994 1145 1490 1242 1573 1739 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 6.42 6.79 10.08 7.29 11.42 13.08 7.58 8.29 10.79 8.79 12.00 13.71 8.21 9.29 11.08 10.29 12.42 14.21 1540 1630 2420 1750 2740 3140 1820 1990 2590 2110 2880 3290 1970 2230 2660 2470 2980 3410 1201 1271 1888 1365 2137 2449 1420 1552 2020 1646 2246 2566 1537 1739 2075 1927 2324 2660 1063 1125 1670 1208 1891 2167 1256 1373 1787 1456 1987 2270 1359 1539 1835 1704 2056 2353 720 793 1098 848 1257 1434 805 891 1287 964 1348 1495 878 1013 1318 1098 1391 1537 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 37. 939 994 1476 1068 1671 1915 1110 1214 1580 1287 1757 2007 1202 1360 1623 1507 1818 2080 625 689 954 737 1092 1246 700 774 1118 837 1171 1299 763 880 1145 954 1208 1336 816 864 1283 928 1452 1664 965 1055 1373 1118 1526 1744 1044 1182 1410 1309 1579 1807 45 S-SL STANDARD GUARANTEED RATINGS In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 528 563 840 595 941 1074 623 679 888 731 990 1126 672 763 916 847 1014 1168 COPPER FINNED TUBING 1" DIA. COPPER 1C-2¾ X 4-32 1C-2¾ X 4-40 1C-2¾ X 4-48 1" DIA. COPPER 1C-3¼ X 3¼-32 1C-3¼ X 3¼-40 1C-3¼ X 3¼-48 1" DIA. COPPER 1C-4¼ X 4¼-32 1C-4¼ X 4¼-40 1C-4¼ X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 4.15 4.43 6.60 4.68 7.40 8.44 4.90 5.34 6.99 5.75 7.78 8.86 5.28 6.00 7.21 6.66 7.98 9.19 997 1063 1584 1122 1775 2026 1175 1280 1676 1379 1868 2125 1267 1439 1729 1597 1914 2204 777 829 1236 875 1385 1580 916 999 1308 1076 1457 1658 988 1122 1349 1246 1493 1719 688 733 1093 774 1225 1398 811 883 1157 952 1289 1466 874 993 1193 1102 1321 1521 608 648 966 684 1083 1236 717 781 1023 841 1139 1296 773 878 1055 974 1168 1345 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 4.79 5.29 7.42 5.71 8.42 9.58 5.42 6.00 8.58 6.50 9.00 10.08 5.92 6.71 8.79 7.29 9.29 10.29 1150 1270 1780 1370 2020 2300 1300 1440 2060 1560 2160 2420 1420 1610 2110 1750 2230 2470 897 991 1388 1069 1576 1794 1014 1123 1607 1217 1685 1888 1108 1256 1646 1365 1739 1927 794 876 1228 945 1394 1587 897 994 1421 1076 1490 1670 980 1111 1456 1208 1539 1704 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 6.29 6.71 10.00 7.08 11.21 12.79 7.42 8.08 10.58 8.71 11.79 13.42 8.00 9.08 10.92 10.08 12.08 13.92 1510 1610 2400 1700 2690 3070 1780 1940 2540 2090 2830 3220 1920 2180 2620 2420 2900 3340 1178 1256 1872 1326 2098 2395 1388 1513 1981 1630 2207 2512 1498 1700 2044 1888 2262 2605 1042 1111 1656 1173 1856 2118 1228 1339 1753 1442 1953 2222 1325 1504 1808 1670 2001 2305 702 775 1086 836 1232 1403 793 878 1257 952 1318 1476 866 982 1287 1068 1360 1507 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. 46 For important ratings information regarding above charts, see page 37. 921 982 1464 1037 1641 1873 1086 1183 1549 1275 1726 1964 1171 1330 1598 1476 1769 2037 610 673 943 726 1071 1219 689 763 1092 827 1145 1283 753 853 1118 928 1182 1309 800 853 1272 901 1426 1627 943 1028 1346 1108 1500 1707 1018 1155 1389 1283 1537 1770 S-SL STANDARD GUARANTEED RATINGS In btu/hr per active (finned) lineal foot of tube at entering air temperature of 65° F FINNED TUBE MODEL Rows Of Finned Tube (On 6-inch Centers) Enclosure Height (in inches) Recommended Minimum Installed Height (in inches) EDR* (ft2⁄ ft) STEAM HEAT 215° Factor of 1.00 HOT WATER HEAT 190° Factor of 0.78 180° Factor of 0.69 170° Factor of 0.61 160° Factor of 0.53 521 553 822 588 923 1056 612 672 875 721 972 1109 665 756 899 833 1000 1151 COPPER FINNED TUBING 1¼" DIA. COPPER 1¼C-2¾ X 4-32 1¼C-2¾ X 4-40 1¼C-2¾ X 4-48 1¼" DIA. COPPER 1¼C-3¼ X 3¼-32 1¼C-3¼ X 3¼-40 1¼C-3¼ X 3¼-48 1¼" DIA. COPPER 1¼C-4¼ X 4¼-32 1¼C-4¼ X 4¼-40 1¼C-4¼ X 4¼-48 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 4.10 4.35 6.46 4.62 7.26 8.31 4.81 5.28 6.88 5.67 7.65 8.72 5.23 5.94 7.07 6.55 7.87 9.05 983 1043 1551 1109 1742 1993 1155 1267 1650 1360 1835 2092 1254 1426 1696 1571 1888 2171 767 813 1210 865 1359 1555 901 988 1287 1060 1431 1632 978 1112 1323 1225 1472 1694 679 720 1070 765 1202 1375 797 874 1139 938 1266 1444 865 984 1170 1084 1302 1498 600 636 946 676 1063 1216 705 773 1007 829 1119 1276 765 870 1035 958 1151 1325 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 4.50 5.08 7.21 5.50 8.21 9.42 5.29 5.79 8.42 6.21 8.79 9.92 5.71 6.58 8.71 7.21 9.08 10.21 1080 1220 1730 1320 1970 2260 1270 1390 2020 1490 2110 2380 1370 1580 2090 1730 2180 2450 842 952 1349 1030 1537 1763 991 1084 1576 1162 1646 1856 1069 1232 1630 1349 1700 1911 745 842 1194 911 1359 1559 876 959 1394 1028 1456 1642 945 1090 1442 1194 1504 1691 1 1 2 1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 12 18 18 24 24 24 12 18 18 24 24 24 12 18 18 24 24 24 16 22 22 28 28 28 16 22 22 28 28 28 16 22 22 28 28 28 6.21 6.58 9.79 7.00 11.00 12.58 7.29 8.00 10.42 8.58 11.58 13.21 7.92 9.00 10.71 9.92 11.92 13.71 1490 1580 2350 1680 2640 3020 1750 1920 2500 2060 2780 3170 1900 2160 2570 2380 2860 3290 1162 1232 1833 1310 2059 2356 1365 1498 1950 1607 2168 2473 1482 1685 2005 1856 2231 2566 1028 1090 1622 1159 1822 2084 1208 1325 1725 1421 1918 2187 1311 1490 1773 1642 1973 2270 659 744 1055 805 1202 1379 775 848 1232 909 1287 1452 836 964 1275 1055 1330 1495 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) lineal foot of tube. For important ratings information regarding above charts, see page 37. 909 964 1434 1025 1610 1842 1068 1171 1525 1257 1696 1934 1159 1318 1568 1452 1745 2007 572 647 917 700 1044 1198 673 737 1071 790 1118 1261 726 837 1108 917 1155 1299 790 837 1246 890 1399 1601 928 1018 1325 1092 1473 1680 1007 1145 1362 1261 1516 1744 47 Accessories 3-1/2" FS5/FS3 8' - *- AX. 12" *- 0" M ENCLOSURES ARE AVAILABLE IN 1 FT. TO 8 FT. LENGTHS IN 6 IN. INCREMENTS 3-1/2" 3-1/2" SECTION "X - X" X SECTION "X - X" X INTERNAL INTERNALJOGGLE-JOINER JOGGLE-JOINER ACCESS DOOR ALSO AVAILABLE IN ENCLOSURE ENCLOSURE HEIGHT 2" ENCLOSURE EXPANSION BRACKET MOUNTING CHANNEL 3-1/2" FULL BACK PANEL SLIP-IN PIPE HANGER SLIP-IN SECOND ROW BRACKET 3-1/2" 12" WIDE ACCESS PANEL (REMOVABLE) SECURITY DAMPER KNOB DAMPER 12" 12" 3-1/2" - * *DOOR 6" x 6" DOOR 6" x 6" FOR * 7 1/2" FS3 9" FOR FS5 WALL TRIM SUPPORT END CAP (LEFT HAND SHOWN) TRIM STRIP 3-1/2" - 5" - 7-1/2" INSIDE CORNER OUTSIDE CORNER 12" WIDE ENCLOSURE WITH ACCESS DOOR (SECURITY LOCK OPT.) 12" WIDE END CAP WITH ACCESS DOOR (SECURITY LOCK OPT.) (ALL ACCESSORIES ARE OVERLAP TYPE, BUTT TYPE OPTIONAL) (ALL ACCESSORIES ARE OVERLAP TYPE, BUTT-TYPE OPTIONAL.) 3-1/2" FSOS - 8' AX. * * M - 0" ENCLOSURES ARE AVAILABLE IN 1 FT. TO 8 FT. LENGTHS IN 6 IN. INCREMENTS 12" - 3-1/2" 3-1/2" SECTION "X - X" X X INTERNAL JOGGLE-JOINER SECTION "X - X" INTERNAL JOGGLE-JOINER ACCESS DOOR ALSO AVAILABLE IN ENCLOSURE ENCLOSURE HEIGHT 2" MOUNTING CHANNEL SLIP-IN SECOND ROW BRACKET 3-1/2" 3-1/2" WALL PIPE HANGER FULL BACK PANEL 3-1/2" * * END CAP (LEFT HAND SHOWN) TRIM STRIP 3-1/2" - 5" - 7-1/2" OUTSIDE CORNER (ALL ACCESSORIES OVERLAP TYPE, BUTT TYPE OPTIONAL.) (ALL ACCESSORIES ARE OVERLAP TYPE, BUTTARE TYPE OPTIONAL) 48 SECURITY DAMPER 12" - WALL TRIM SUPPORT KNOB DAMPER 12" * - INSIDE CORNER DOOR 6" x 6" DOOR 6" x 6" 7 1/2" FOR FSOS3 9" FOR FSOS5 12" WIDE ENCLOSURE WITH ACCESS DOOR (SECURITY LOCK OPT.) 12" WIDE END CAP WITH ACCESS DOOR (SECURITY LOCK OPT.) Accessories 3-1/2" ENCLOSURES ARE AVAILABLE IN 1 FT. TO 8 FT. LENGTHS IN 6 IN. INCREMENTS 8' - FT5/FT3 *- AX. 12" *- 0" M 3-1/2" 3-1/2" X X ACCESS DOOR ALSO AVAILABLE IN ENCLOSURE SECTION "X - X" INTERNAL JOGGLE-JOINER SECTION "X - X" INTERNAL JOGGLE-JOINER 8' - FF5/FF3 *- AX. 3-1/2" 12" *- 0" M 3-1/2" 3-1/2" X X ACCESS DOOR ALSO AVAILABLE IN ENCLOSURE SECTION "X -SECTION X" "X - X" INTERNAL JOGGLE-JOINER INTERNAL JOGGLE-JOINER 8' - *- AX. 3-1/2" 12" *- 0" M 3-1/2" 3-1/2" FR5/FR3 X X ACCESS DOOR ALSO AVAILABLE IN ENCLOSURE SECTION "X -SECTION X" "X - X" INTERNAL JOGGLE-JOINER INTERNAL JOGGLE-JOINER ENCLOSURE HEIGHT 2" MOUNTING CHANNEL ENCLOSURE EXPANSION BRACKET SLIP-IN PIPE HANGER SLIP-IN SECOND ROW BRACKET 3-1/2" 3-1/2" FULL BACK PANEL SECURITY DAMPER KNOB DAMPER 3-1/2" *- DOOR 6" x 6" * TRIM STRIP 3-1/2" - 5" - 7-1/2" END CAP (LEFT HAND SHOWN) OUTSIDE CORNER 12" 12" *- 7 1/2" FOR LOW PROFILES 9" FOR STANDARD WALL TRIM SUPPORT 12" WIDE ACCESS PANEL (REMOVABLE) DOOR 6" x 6" 12" WIDE ENCLOSURE WITH ACCESS DOOR (SECURITY LOCK OPT.) INSIDE CORNER 12" WIDE END CAP WITH ACCESS DOOR (SECURITY LOCK OPT.) (ALL ACCESSORIES ARE OVERLAP TYPE, BUTT TYPE OPTIONAL) (ALL ACCESSORIES ARE OVERLAP TYPE, BUTT-TYPE OPTIONAL) S-SL 3-1/2" 3-1/2" 3-1/2" 9" 9" 12" 12" DOOR 6" x 6" DOOR 6" x 6" TRIM STRIP 3-1/2" - 5" - 7-1/2" END CAP (LEFT HAND SHOWN) OUTSIDE CORNER INSIDE CORNER 12" WIDE ENCLOSURE WITH ACCESS DOOR (w/ ALLEN KEY LOCK) 12" WIDE END CAP WITH ACCESS DOOR (w/ ALLEN KEY LOCK) 49 Applications Z-CORNER ENCLOSURE FR5 Z-CORNER LEFT HAND SHOWN * WALL A ** FS5 Z-CORNER RIGHT HAND SHOWN * B B WALL C *** TOP VIEW FS5 Z-CORNER LEFT HAND SHOWN **** C ** WALL WALL A *** TOP VIEW FS5 Z-CORNER RIGHT HAND SHOWN **** * Z-CORNERS ARE AVAILABLE FOR ALL ENCLOSURE STYLES ** DIMENSION MUST BE MIN. 1-5/8" LARGER THAN THE ENCLOSURE DEPTH (TYP. USE SUBMITTAL INSIDE CORNER WALL LENGTH) *** DIMENSION MUST BE MIN. 1-1/2" (TYP. USE SUBMITTAL OUTSIDE CORNER WALL LENGTH) **** WHEN ORDERING SPECIFY ENCLOSURE STYLE, DIMENSIONS LISTED FROM LEFT TO RIGHT & LH or RH STYLE Z-CORNER 50 Applications COLUMN ENCLOSURE ** Column depth must be at least 5" larger than Enclosure depth. ** (L.H. FS Style Enclosure Shown) Standard Column corners may be field cut to shorter lengths. Column trims used to finish enclosure 51 RATINGS CORRECTION DATA TABLE 1 - Installed Height Correction Data INSTALLED HEIGHT (in.) 18 or less 19 20 21 22 23 24 25 26 27 28 29 30 32 34 36 or less HEATING-EFFECT FACTOR 1.065 1.060 1.056 1.052 1.047 1.043 1.039 1.035 1.030 1.026 1.022 1.017 1.013 1.009 1.004 1.000 If finned tube is to be mounted in an enclosure having an installed height which is greater than the minimum recommended in the ratings table, and if the installed height is greater than 18 inches, the steam- and hot-water-heat ratings shown for the finned tube must be corrected by multiplying by a correction factor: Installed-Height Correction Factor = Heating-Effect Factor for Actual Installed Height Heating-Effect Factor for Recommended Minimum Installed Height (Example: One row of 1-1/4C - 4-1/4 - 48 finned tube is mounted in an ETO enclosure which is 4-5/8 inches high and is installed 26 inches from the floor instead of the recommended 8-5/8 inches from the floor. Correction factor = 1.030/1.065 = 0.9671. At an average water temperature of 180°F, this enclosure will deliver 990 x 0.9671 = 957 BTU/ hr./ft.) TABLE 2 - Steam-Heat Correction Factors: Nonstandard Steam Pressures and Entering Air Temperatures STEAM ENTERING AIR TEMPERATURE (°F) PRESSURE GAGE (psig) * PRESSURE ABSOLUTE (psia) * TEMPERATURE (°F) † 45 55 65 70 75 80 85 90 100 110 120 130 140 150 0 14.70 212.0 1.19 1.09 0.97 0.92 0.87 0.82 0.77 0.70 0.63 0.54 0.46 0.38 0.31 0.25 0.9 15.60 215.0 1.22 1.11 1.00 0.95 0.90 0.84 0.80 0.75 0.65 0.57 0.48 0.40 0.33 0.26 5 19.70 227.1 1.34 1.22 1.11 1.05 1.00 0.95 0.90 0.81 0.75 0.66 0.57 0.49 0.41 0.34 10 24.70 239.4 1.45 1.33 1.22 1.17 1.11 1.05 1.00 0.91 0.85 0.75 0.66 0.58 0.50 0.42 15 29.70 249.8 1.55 1.43 1.31 1.26 1.20 1.14 1.09 1.00 0.94 0.84 0.75 0.66 0.57 0.49 20 34.70 258.8 1.63 1.52 1.40 1.33 1.28 1.23 1.17 1.07 1.02 0.92 0.82 0.73 0.64 0.55 30 44.70 247.0 1.78 1.66 1.54 1.48 1.42 1.37 1.31 1.21 1.15 1.05 0.95 0.85 0.76 0.68 40 54.70 286.7 1.91 1.79 1.66 1.61 1.54 1.49 1.43 1.32 1.27 1.16 1.06 0.97 0.87 0.78 50 64.70 297.7 2.02 1.90 1.77 1.71 1.65 1.60 1.54 1.42 1.37 1.26 1.16 1.06 0.96 0.87 Use of table: Multiply BTU shown for steam heat (at 215°F) in Ratings table by appropriate correction factor given above to obtain corrected steam-heat rating. *Corrected for altitude. † From Keenan, J.H and Keyes, FG., Thermodynamic Properties of Steam, John Wiley & Sons, Inc., New York, 1936 TABLE 3 - Hot-Water-Heat Correction Factors: Nonstandard Entering Water Temperatures AVERAGE WATER TEMPERATURE (°F) ENTERING AIR TEMPERATURE (°F) 240 230 220 210 200 190 180 170 160 45 1.47 1.37 1.27 1.18 1.09 1.00 0.91 0.82 0.73 50 1.41 1.30 1.21 1.12 1.03 0.94 0.86 0.77 0.69 55 1.35 1.24 1.15 1.06 0.97 0.89 0.81 0.72 0.64 60 1.29 1.19 1.09 1.01 0.92 0.84 0.75 0.67 0.59 70 1.17 1.08 0.98 0.90 0.81 0.73 0.65 0.57 0.49 75 1.12 1.03 0.93 0.85 0.77 0.69 0.61 0.53 0.45 80 1.07 0.98 0.88 0.80 0.72 0.64 0.56 0.48 0.40 85 1.02 0.93 0.84 0.76 0.68 0.60 0.52 0.44 0.36 Use of table: Multiply BTU shown for steam heat (at 215°F) in Ratings table by appropriate correction factor given above to obtain corrected hot-water-heat rating. TABLE 4 - Hot-Water-Heat Correction Factors: Nonstandard Average Water Temperature AVERAGE WATER TEMPERATURE (°F) 300 290 280 270 260 250 150 140 130 120 110 100 CORRECTION FACTOR 1.87 1.76 1.64 1.54 1.44 1.39 0.45 0.40 0.33 0.26 0.20 0.15 Use of table: Multiply BTU shown for steam heat (at 215°F) in Ratings table by appropriate correction factor given above to obtain corrected hot-water-heat rating. 52 RATINGS CORRECTION DATA FIGURE 1 - Hot-Water-Heat Correction Factors (And Water Pressure Drops): Water Velocities Less Than 3fps TOTAL BTU REQUIRED 20°F 30°F TEMP. TEMP. DROP DROP WATER FLOW RATE (gpm) 90,000 180,000 270,000 18 80,000 160,000 240,000 16 70,000 140,000 210,000 14 60,000 120,000 180,000 12 50,000 100,000 150,000 10 40,000 80,000 120,000 8 30,000 60,000 90,000 6 20,000 40,000 60,000 4 10,000 20,000 30,000 2 0 0 0 0 FEET PER SECOND 18 GALLONS PER MINUTE 10°F TEMP. DROP 16 14 E TUB EEL ER TUBE T S " 1-1/4 /4" COPP 1-1 BE PER TU 1" COP EEL 1" ST 12 10 8 6 ER TUBE 4 3/4" COPP 2 0 .25 .50 .75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 WATER VELOCITY (fps) .25 .50 .75 WATER VELOCITY CORR. FACTOR .905 .931 .946 .951 .966 1" COPPER TUBE .06 .20 .39 .64 .93 1.27 1.65 2.08 2.53 3.00 3.53 4.10 1-1/4" COPPER TUBE .04 .15 .30 .48 .72 .98 1.28 1.60 1.98 2.43 2.85 3.32 PRESSURE DROP (ft. of water per 100 ft. of tube) 1.00 1.25 1.50 1.75 .973 .979 2.00 2.25 .984 2.50 .988 2.75 .992 3.00 .996 1.00 Use of table: Multiply Btu shown for hot-water heat in Ratings table by correction factor found above to obtain corrected hot-water-heat rating. FIGURE 2 - Effect of Water Velocity on Finned Tube Output THE EFFECTS OF WATER VELOCITY ON FINNED TUBE OUTPUT. 1.1 TEMPERATURE RISE (°F) Figure 2 shows rating factors that can be utilized when the water velocity falls below 3 f.p.s. It is recommended when designing low-load systems that the water velocity be a key factor in element selection. Figure 3 can be used to ensure that the water velocity is above the critical level with various tube sizes. For more information on this topic, please refer to the 1969 equipment volume of ASHRAE Guide and Data Book Page #393. The Institute of Boiler and Radiator Manufacturers sponsored a test program at the University of Illinois to determine the effect of water velocity on heat output of various sizes of finned tubed element. The results of this test show that when the water velocity falls below 0.4 f.p.s., the flow changes from turbulent to streamline. With systems designed at water velocities below this point the output cannot be accurately predicted so should always be avoided. 1.0 RATING POINT 3 FPS 0.9 0.8 0.7 0.6 0 1 2 3 4 5 6 WATER VELOCITY (FT./SEC.) FIGURE 3 - Water Velocity in Ft./Sec. VS G.P.M. 1" .6 P CO E T "S 1 ER PP .5 EL CO L EE /4" ST " 4 / 1-1 .4 1-1 .3 .2 CRITICAL VELOCITY .1 0 .2 .4 .6 .8 1.0 1.2 1.4 RATE OF FLOW (G.P.M.) 1.6 1.8 CO PP 1" 3/ 4" .7 R PE 4 WATER VELOCITY (FT./SEC.) ”C 3/4 WATER VELOCITY (FT./SEC.) .8 R PE ER OP PE R .9 P CO 1" EL E ST /4 1-1 3 ER PP O "C EL TE "S /4 1-1 2 1 0 2 4 6 8 10 RATE OF FLOW (G.P.M.) 12 14 53 RATINGS CORRECTION DATA TABLE 5 - Thermal Expansion in Pipe 120 140 160 180 200 220 240 260 280 300 STEEL PIPE .396 .550 .709 .869 1.032 1.193 1.361 1.524 1.691 1.816 COPPER PIPE .576 .800 1.014 1.261 1.506 1.726 1.966 2.195 2.428 2.671 TEMPERATURE OF MEDIUM ELONGATION (in/100 ft.) The table above indicates elongation in inches/100 ft. at the temperature shown when the pipe was installed at 70°F. TEMPERATURE RISE (°F) FIGURE 4 - Lineal Expansion of Finned Tube E UB 300 T EL 200 BE STEAM STEAM PRESSURE PRESSURE PSIG PSIA U R T E PP CO E ST TABLE 6 - PROPERTIES OF SATURATED STEAM 100 0 .5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 LINEAL EXPANSION (inches/100 ft.) TABLE 7 - HEAT LOSS FROM BARE PIPE & TUBING (Btu per hour per foot per degree F difference) HORIZONTAL BARE STEEL PIPE AVERAGE TEMPERATURE DIFFERENCE BETWEEN HEATING MEDIUM AND 70°F AIR (°F) NOMINAL PIPE SIZE (in.) 50 80 1/2 .455 .495 .546 .584 3/4 .555 .605 .666 .715 1 .684 .743 .819 .877 1-1/4 .847 .919 1.014 1.086 1-1/2 .958 1.041 1.148 1.230 2 1.180 1.281 1.412 1.512 2-1/2 1.400 1.532 1.683 1.796 110 140 BOILING POINT OF STEAM TEMP. VOLUME OF 1 LB OF STEAM CU. FT. 54 LATENT HEAT OF EVAP. Btu. TOTAL HEAT OF STEAM Btu. .899 14.70 212.0 26.79 180.0 970.4 1150.4 1 15.70 215.3 25.20 183.3 968.2 1151.6 2 16.70 218.5 23.78 186.6 966.2 1152.8 4 18.70 224.4 21.40 192.5 962.4 1154.9 6 20.70 229.8 19.45 198.0 958.8 1156.8 8 22.70 234.8 17.85 203.0 955.5 1158.6 10 24.70 239.4 16.49 207.7 952.5 1160.2 15 29.70 249.8 13.87 218.2 945.5 1163.7 25 39.70 266.8 10.57 235.6 933.6 1169.2 50 64.70 297.7 6.68 267.2 911.2 1178.4 75 89.70 320.1 4.91 290.3 894.2 1184.4 100 114.70 337.9 3.891 308.8 880.0 1188.8 125 139.70 352.9 3.225 324.4 867.8 1192.2 GLYCOL SOLUTION CORRECTION FACTORS Propylene Glycol Solution By Volume ProHeat Transfer @ 180°F HORIZONTAL TARNISHED STEEL PIPE AVERAGE TEMPERATURE DIFFERENCE BETWEEN HEATING MEDIUM AND 70°F AIR (°F) HEAT OF THE LIQUID Btu. Freezing point for Propylene Glycol Solutions Factor 20% .97 50% .90 20% +17°F 30% +4°F 40% -13°F 50% -28°F 55% – NOMINAL PIPE SIZE (in.) 50 80 1/2 .250 .287 .300 .321 3/4 .340 .381 .409 .429 1 .440 .475 .509 .536 1-1/4 .500 .559 .618 .622 Approximate Factors for Corrective Heat Values at Varying Altitudes 1-1/2 .580 .656 .710 .750 ALTITUDE 2 .730 .825 .890 .957 2-1/2 .880 1.000 1.091 1.153 110 140 BTU/FT2 EDR* FACTOR Sea Level - 1000 ft. 240 1.000 1000 ft. - 3000 ft. 230 .958 3000 ft. - 5000 ft. 223 .929 5000 ft. - 7000 ft. 216 .900 7000 ft. - 10,000 ft. 209 .871 *EDR - Equivalent Direct Radiation area (for steam heat) per active (finned) linear foot of tube. Engineering Specifications General: Furnish and install finned tube heating elements and enclosures as indicated on plans, with required mounting components and accessories. Material shall be manufactured in accordance with Rittling’s High Quality Standards and in conformance to ISO 9001: 2000 standards established and maintained by Hydro-Air Components Inc. of Hamburg, New York. Steel Heating Elements: Steel heating elements shall consist of galvanized fins permanently bonded to high pressure tubing by mechanically expanding the steel tubing to the steel fins. Copper-Aluminum Heating Elements: Copper-Aluminum heating elements shall consist of aluminum fins permanently bonded to copper seamless drawn tubing by mechanically expanding the copper tubing to the aluminum fins. Mounting Channel or Full Back Panel: Mounting channel shall be die formed from 23-gauge galvannealed steel and the full back panel from 20-gauge galvannealed steel. For rigidity, the top projection of the mounting channel or full back panel shall position the enclosure away from the wall so as to allow for installation or removal of enclosure without damage to wall. A urethane gasket is available to form air seal at wall (optional). Hanger Brackets: All hanger brackets shall be die formed for rigidity. Brackets used for first row or one row of finned tube shall incorporate a positive-lock mounting clip for the enclosure. Brackets will be self-gauging, allowing for a single measurement installation. All hangers must provide for lengthwise movement of elements during expansion and contraction as well as aligning elements to prevent contact with brackets, walls, or enclosure. Enclosures & Accessories: Enclosures shall be of the type as shown on the drawings. Enclosures shall be manufactured from 14-16-18-gauge cold rolled steel. All enclosures shall be reinforced with welded gussets. The joining of enclosure shall be accomplished by use of internal joggle joiners to provide for hairline joints and added rigidity. No sheet metal screws or other fastening devices shall be visible. Securing the top portion of the enclosure to the wall will be accomplished by use of a full length mounting channel or full back panel. The lower portion of the enclosure will be secured by use of a positive-locking, bottom-mounting clip using fasteners, thus preventing removal without tools. Dampers: Enclosure dampers shall be provided where indicated. Damper blades shall be fabricated from 18-gauge galvanized material painted to match enclosure color. Threaded damper screw and trunion shall provide positive operation of blade to provide variable heat output. Damper shall be operated by solid plastic damper knobs attached to damper screw. Recessed security allenhead operators shall be used in secure areas as indicated. Consult factory on enclosure heights of 8" or below. Access Doors: Access doors shall be provided where noted on plans. Doors shall be 6" x 6". Doors shall be hinged and have slotted operators. Recessed security allenhead operators shall be used in secure areas as indicated. Doors shall be positioned directly in enclosure (in 12" long access panel). Consult factory on enclosure heights of 8" or below. Paint: All enclosures and accessories shall be degreased and chemically phosphatized before application of a durable, attractive, electrostatic epoxy powder coating. Decorator colors are available from Rittling’s Color Selector Chart. 55 SPECIAL APPLICATIONS Zehnder Rittling’s reputation for leadership in commercial heating systems design and fabrication thrives on a demonstrated ability to modify or adapt components from our vast standard inventory and to break new ground with innovative applications. Our ingenuity and expertise free architects from the constraints of hydronic-heating conventions. We can, for instance, customize enclosures to any dimensions in stainless, textured embossed steel... or aluminum, for installation anywhere: in ceilings... walls... or trenches. We’ll angle finned tube systems to match the slope of a floor. We’ll fabricate all copper heating elements, bronze anodized and other specialty outlet grilles, or pipe enclosures without grilles. Challenge us and we’ll build it! If you have a special application you would like us to evaluate, please call to arrange a consultation with a Zehnder Rittling expert. Zehnder Rittling guarantees its products to be free from defects in material and workmanship for a period of one year from date of shipment from our Buffalo, New York factory. Should there be any defects in the good(s), the purchaser should promptly notify Zehnder Rittling and upon receipt of written consent from Zehnder Rittling, the purchaser shall return the defective good(s) to the factory for inspection with freight prepaid. If inspection shows the goods to be defective, Zehnder Rittling will at its discretion repair or replace the said item(s). Defects arising from damage due to shipment, improper installation, negligence or misuse by others are not covered by this warranty. This warranty is extended only to the original purchaser from Zehnder Rittling. ISO 9001 BUREAU VERITAS Certification No 209940 Zehnder Rittling 100 Rittling Boulevard · Buffalo · NY · USA · 14220 Tel. 716-827-6510 · Fax 716-827-6523 sales@zehnder-rittling.com · www.zehnder-rittling.com © Zehnder Rittling January 2011, English, subject to change without notice WARRANTY