SPC - Solar
Operation Manual
Product Specificatons
Model
SPC-Solar 2
SPC-Solar 5
Lower Range
0 - 2.2 lb x 0.002 lb
0 - 2 lb 3 oz x 0.05 oz
0 - 35 oz x 0.05 oz
0 - 1000 g x 1 g
0 - 5.5 lb x 0.05 lb
0 - 5 lb 8 oz x 0.1 oz
0 - 88 oz x 0.1 oz
0 - 2500 g x 2 g
High Range
2.2 - 4.4 lb x 0.005 lb
2 lb 3 oz - 44 lb 6oz x 0.1oz
35 - 70 oz x 0.1 oz
1000 - 2000 g x 2 g
5.5 - 11 lb x 0.01 lb
5 lb 8 oz - 11 lb 2 oz x 0.2 oz
88 - 178 oz x 0.2 oz
2500 - 5000 g x 5 g
Maximum Tare
2.190 lb
2 lb 2.75 oz
34.75 oz
995 g
5.475 lb
5 lb 7.5 oz
87.5 oz
2490 g
System Parameter
Operation
1
Display
Press and hold the
key and press
+
keys to
go to system parameter mode under the weighing mode.
The
indicator blinks during system parameter
indicator lights up
2
The operation under system parameter mode is as follows
: Move parameter No. forward (+1)
: Move setting value forward (+1)
: Move setting value backward (-1)
* Be sure to set the setting value among available
parameter values shown on the parameter list. When
the setting value you desire has passed, press the
key to move backwared (-1).
Long Press the
key to turn off the power to save the
setting value in the memory
1
YCO-130607
SPC - Solar
Operation Manual
Parameter List
( # 01 - 04: User parameter, # 05 - 09: System parameter)
Parameter
01
Description
Power Select
02
Weighing units
at power on
03
Checkweighing
function
Auto-off timer
04
05
Gravity
compensation
06
Capacity
07
Zero tracking
08
09
Not used
Not used
Available parameter
000:
Solar-powered operation (Default)
001:
Battery-powered operation (Quick response)
002:
Hybrid (Solar + Battery) operation
(The response speed is the same as 000)
000:
g
001:
lb (Default)
002:
oz
003:
lb.oz
000:
Disabled
001:
Enabled (Default)
000:
Disabled
001-009: Set by one minute (5 minute: Default)
000:
Disabled
001-029: Prohibited to set
030-210: (Acceleration of Gravity (m/s2) - 9.7600) x 10000/5 + 30
(offset)
Setting range: 9.7600 to 9.8500 m/s2
Minimum setting unit: 0.0005 m/s2
000:
2000 g
001:
5000 g
000:
Disabled
001:
Enabled (Default)
2
YCO-130607
SPC - Solar
Operation Manual
Calibration
Prepare "kilogram" check weights (more than OIML M1 class) corresponding to the capacity. It is not possible to calibrate the SPC-Solar with either "pound" or "ounce" check weight. Be sure to calibrate the scale under battery-powered mode.
Operation
1
2
3
Install batteries.
Set the user parameter No. 01 (power select) at 001
(battery-powered operation)
Press and hold the
key and press the
to user parameter mode.
key to go
Press and hold the
to calibration mode
key to go
key and press the
After confirming, the stable indicator
the
4
Display
lights up, press
key.
Place a check weight corresponding to the scale
capacity.
SPC - Solar 2: 2,000 grams
SPC - Solar 5: 5,000 grams
5
When the stable indicator lights up, press
key.
If the display shows as right figures, calibration has been
completed successfully
If there is the following differences for the values in the
right figures, turn off the power and try to calibrate it
again
Capacity 2 kg
Capacity 5 kg
SPC - Solar 2: more than +/- 5 counts
SPC - Solar 5: more than +/- 10 counts
After calibration, turn off the power. Turn on the power
again and confirm that correct weight value is displayed
3
YCO-130607
SPC - Solar
Operation Manual
Error Messages
When one of the following error messages appears on the display, follow the troubleshooting instructions.
Contact the retailer from which the product was purchased, if other messages than the following appear,
or an error is not recovered after following the troubleshooting.
Display
Cause
Batteries are running out.
Out of batteries
The weight below zero
This message appears when
the weighed value is less
than - 5 divisions (- 5 g for the
weighing capacity of 2000 g).
Troubleshooting
Replace all of the batteries
with new one. Do not use old
and new batteries or alkaline
and magnesium batteries at
a time.
Press the
key.
If the pan has been removed,
set it on the scale again.
This message appears when
the weighed value is over
+5 divisions (2010g for the
weighing capacity of 2000g).
When the item is removed,
the display returns to the
weighing screen. Make sure
to use the scale within the
capacity.
Turned on the scale while a
heavy item was placed
Remove the item from the
pan, and then press the
key
Turn on the scale while a
foreign material was stuck
between the main body and
the pan
Check if a foreign material is
not stuck or does not contact
the pan. Then press the
key.
Overloading
The initial error (A)
The initial error (B)
Pressed the
key while a
heavy item was on the pan in
the middle of the operation
The initial error (C)
The initial error (D)
Turned on the scale while
the item was left on a pan.
Remove the item and press
the
key
4
The weight of the item is
beyond the level where the
key is operative.Remove
the item from the pan, and
then press the
key.
Make sure that nothing is left
on the pan and turn on the
scale again.
YCO-130607
SPC - Solar
Operation Manual
Wiring Diagram
5
YCO-130607
SPC - Solar
Operation Manual
Parts List
6
YCO-130607
SPC - Solar
Operation Manual
Parts List
Item
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17,18,20,23,25
19
21
22
24
Part #
63910024
63910028
63910025
63910020
63910102
63910103
63911031
63900031
63900032
63900023
63901034
63900037
63900035
63910036
63910034
63910033
63910021
63910022
63911001
63911002
63911003
63911004
63911005
Description
Platform Cover, S.S.
Plate, Platform Support
Cushion Rubber
Upper Housing
Load cell + PCB Assembly, 2 kg
Load cell + PCB Assembly, 5 kg
Battery Box
Battery Box Holder
Battery Lid with sponge
Holding Plate / CPU Board
Solar Panel
Membrane Key Switch
Front Mask, SPC - Solar 2
Front Mask, SPC - Solar 5
Solar Glass
Display Glass
Base
Rubber Foot
Hex Bolt & SW, M3X6, S.S.
Screw & Washer, M2X6 / Battery Box
Hex Bolt, M4X8, S.S. / Battery Lid
Screw & Washer, M3X6 / CPU Board
Hex Nut M4 / Rubber Foot
7
Qty / Unit
1
1
4
1
1
1
1
1
1
1
2
1
1
1
2
1
1
4
17
2
2
4
4
YCO-130607
SPC - Solar
Operation Manual
YAMATO CORPORATION
www.YamatoCorp.com
1775 S. Murray Blvd.
Colorado Springs, CO 80916 USA
Tel (719) 591-1500 Fax (719) 591-1045
YAMATO TECH CORPORATION
#112-19425 Langley By-Pass
Surrey, B.C. V3S 6K1 Canada
Tel (604) 533-2338 Fax (604) 533-0827
YCO-130607
Download