United Utilities Operational Noise Assessment Proposed Fleetwood Wind Turbine ANNEX 1 - Extracts of Noise Data for the EWT DW54 500kW Wind Turbine Emergya Wind Technologies BV Engineering Category: Specification Page 1 / 2 Doc code: S-1005020 Created by: TY Creation Date: 07-12-11 Checked by: MS Checked Date: 07-12-11 Approved by: TY Approved Date: 07-12-11 Title: Specification Sound power warranty levels DW52/54 500kW Revision Date Author Approved Description of changes 02 14-03-12 AB TY Modifications based on new IEC measurements 01 09-12-11 AB TY correction - - - - - - - - - - - - - - - - - - - - Emergya Wind Technologies BV Building ‘Le Soleil’ - Computerweg 1 - 3821 AA Amersfoort - The Netherlands T +31 (0)33 454 0520 - F +31 (0)33 456 3092 - www.ewtinternational.com © Copyright Emergya Wind Technologies BV, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. Category: Specification Revision: 02 Title: Sound power warranty levels DW52/54 500kW Page 2 / 2 Doc code: S-1005020 Sound power levels The warranted sound power levels are presented with reference to IEC 61400-11:2002. Vwind at 10m height DW52 DW54 5 m/s 96,5 dB(A) 97.0 dB(A) 6 m/s 97.5 dB(A) 98.0 dB(A) 7 m/s 98.5 dB(A) 99.0 dB(A) 8 m/s 99.5 dB(A) 100.0 dB(A) 9 m/s 100.3 dB(A) 100.5 dB(A) 10 m/s 100.5 dB(A) 100.5 dB(A) Sound power level Lw in dB(A) The warranted sound power levels are based on actual measurements executed by an independent noise measurement institute according to the preferred methods set out in IEC-61400-11. Uncertainty levels are included in the warranted sound power levels. At 5m/s a maximum tonal noise penalty of 2,5dB shall be considered according to ETSU-R-97 guidelines. The measured third octave sound power levels are available upon request. The values given in the table are valid for normal operational mode (rotation speed 0-24 RPM) The calculation of the standardized wind speed at 10m height according to IEC 61400-11 is based on a terrain roughness length Z0=0,05m. In case validation measurements have to be performed, they should be executed according to the preferred methods set out in IEC-61400-11 by an independent measurement institute which is accredited to ISO/IEC 17025 to conduct measurements of wind turbine noise emissions. EWT reserves the right to make modifications or adjust settings in order to comply with the warranted sound power levels. © Copyright Emergya Wind Technologies bv, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. Emergya Wind Technologies BV DW54 Category: Specification Page 1 / 10 Doc code: S-1005030.docx Created by: RH Creation Date: 09-05-12 Checked by: LE Checked Date: 09-05-12 Approved by: TY Approved Date: 09-05-12 Title: Specification Sound power level DW54 - 500kW Revision Date Author Approved Description of changes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Emergya Wind Technologies BV Building ‘Le Soleil’ - Computerweg 1 - 3821 AA Amersfoort - The Netherlands T +31 (0)33 454 0520 - F +31 (0)33 456 3092 - www.ewtinternational.com © Copyright Emergya Wind Technologies BV, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. Category: Specification Revision: 00 Title: Sound power level DW54 - 500kW Page 2 / 10 Doc code: S-1005030.docx Contents 1 Introduction ___________________________________________________________ 3 2 Measurements _________________________________________________________ 4 3 Results _______________________________________________________________ 5 3.1 Corrected sound power level graphical ________________________________________________ 6 3.2 Tonal Audibility__________________________________________________________________ 7 3.3 Uncertainty_____________________________________________________________________ 8 Appendix 1 Third octave band sound power levels _____________________________________ 9 Appendix 2 measured sound pressure levels _________________________________________ 10 © Copyright Emergya Wind Technologies bv, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. Category: Specification Revision: 00 Title: Sound power level DW54 - 500kW Page 3 / 10 Doc code: S-1005030.docx 1 Introduction Following information with regard to the sound power level measurements, are distillated from measurement data of a DIRECTWIND 54 500kW turbine, located at the Elbaweg in Venhuizen, the Netherlands. The measurements were performed by a third party according to the International Standard IEC 64100-11 December 2002: "Wind turbine generator systems – Part 11: Acoustic noise measurement techniques ". © Copyright Emergya Wind Technologies bv, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. Category: Specification Revision: 00 Title: Sound power level DW54 - 500kW Page 4 / 10 Doc code: S-1005030.docx 2 Measurements The measurements have been performed by measuring the sound pressure levels in the third octave bands of 25 Hz to 10,000 Hz at the reference point downwind of the operating turbine. The background noise level was measured during standstill of the turbine. Measurements were carried out on the ground on a hard board according to the IEC standard. This method doubles the pressure on the microphone which raises the sound pressure level with +6 dB(A) compared to free field measurements. The measured sound pressure levels can be found in Appendix 2 measured sound pressure levels. © Copyright Emergya Wind Technologies bv, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. Category: Specification Revision: 00 Title: Sound power level DW54 - 500kW Page 5 / 10 Doc code: S-1005030.docx 3 Results The sound power levels are calculated from the measured sound pressure levels according to IEC-61400-11. The wind velocities have been corrected for a reference roughness Z0 of 0.05m by applying a factor of 1.1 on the measured wind velocity, and the sound power levels have been calculated for a reference height of 10m. Table 3.1 gives the calculated sound power levels at the different wind speeds, and the calculated octave band power levels. Figure 3.1 gives the calculated 3rd octave band sound power levels, the values for these can be found in Appendix 1 Third octave band sound power levels. Sound power level Lw in dB(A) and dB middle frequency of the octave bands [hz] Wind speed at a height of 10m 31.5 63 125 250 500 1k 2k 4k 8k Wind 5 m/s 95.3 dB(A) 95.0 dB 67.3 76.3 82.5 89.0 90.3 87.9 85.3 80.6 71.0 Wind 6 m/s 96.5 dB(A) 96.6 dB 68.2 78.0 84.1 90.7 92.0 89.5 86.7 81.4 72.4 Wind 7 m/s 97.8 dB(A) 97.7 dB 69.5 79.3 85.5 91.8 93.0 90.7 88.0 82.2 72.9 Wind 8 m/s 98.9 dB(A) 98.8 dB 70.9 80.7 86.9 92.6 94.1 92.0 89.2 83.0 72.8 Wind 9 m/s 99.6 dB(A) 99.7 dB 72.4 82.1 88.3 93.5 94.7 92.9 90.3 83.5 72.0 Wind 10 m/s 99.8 dB(A) 99.5 dB 72.2 81.6 87.8 93.1 94.4 93.0 90.5 83.6 71.8 Table 3.1 Sound power levels and the octave band data 100.0 90.0 80.0 Lw [dB(A)] 70.0 60.0 50.0 40.0 Wind 5 m/s Wind 6 m/s Wind 7 m/s 30.0 Wind 8 m/s 20.0 Wind 9 m/s 10.0 Wind 10 m/s 25Hz 31.5Hz 40Hz 50Hz 63Hz 80Hz 100Hz 125Hz 160Hz 200Hz 250Hz 315Hz 400Hz 500Hz 630Hz 800Hz 1kHz 1.25kHz 1.6kHz 2kHz 2.5kHz 3.15kHz 4kHz 5kHz 6.3kHz 8kHz 10kHz 12.5kHz 0.0 Figure 3.1 The 3rd octave band Sound Power Level spectra © Copyright Emergya Wind Technologies bv, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. Category: Specification Revision: 00 Title: Sound power level DW54 - 500kW Page 6 / 10 Doc code: S-1005030.docx 3.1 Corrected sound power level graphical Figure 3.2 below gives all the calculated sound power levels at the different wind speeds at reference conditions (h = 10 m and z0 = 0.05 m) and after correction for the background noise. The figure also gives the 4th order regression on this curve: Figure 3.2 the calculated sound power level at different wind speeds © Copyright Emergya Wind Technologies bv, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. Category: Specification Revision: 00 Title: Sound power level DW54 - 500kW Page 7 / 10 Doc code: S-1005030.docx 3.2 Tonal Audibility The audibility of the tones in the sound was analysed at the reference position and is given in Table 3.2 Tonal Audibility. The most important frequencies are 2.2 and 4.4 kHz. In Table 3.2 also the tonal penalty according to ETSU-R-97 (The assessment and rating of noise from wind farms – September 2006) is given. For the tone level of 3.3, the ETSU penalty of 2.5 dB can be found in Figure 3.3. No penalties are incurred for audibility levels below 2.0 dB. According to ETSU-R-97, the tonal penalty should be added at the receiver for the specific wind speed at which the tonal audibility is present. Wind @ 10 m ([m/s] 5 6 7 8 9 ΔLA [dB(A)] 3.3 0.9 1.5 0.7 -0.7 ETSU Penalty [dB] 2.5 - - - - Table 3.2 Tonal Audibility Figure 3.3 Tonal penalty according to ETSU-R-97 © Copyright Emergya Wind Technologies bv, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. Category: Specification Revision: 00 Title: Sound power level DW54 - 500kW Page 8 / 10 Doc code: S-1005030.docx 3.3 Uncertainty The following Table 3.3 gives the number of measurements and the uncertainty in dB(A) for each different wind speed. Wind Class Number of measurements Uncertainty [dB(A)] Wind 5 m/s 4 1.7 Wind 6 m/s 37 1.4 Wind 7 m/s 77 1.2 Wind 8 m/s 68 0.9 Wind 9 m/s 26 0.9 Wind 10 m/s 9 0.7 Table 3.3 Number of measurements and uncertainty © Copyright Emergya Wind Technologies bv, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. Category: Specification Revision: 00 Title: Sound power level DW54 - 500kW Page 9 / 10 Doc code: S-1005030.docx Appendix 1 Third octave band sound power levels V10[m/s] 25Hz 31.5Hz 40Hz 50Hz 63Hz 80Hz 100Hz 125Hz 160Hz Wind 5 m/s 56,4 61,6 65,4 68,0 71,2 73,6 75,7 77,6 79,2 Wind 6 m/s 57,6 63,0 66,1 69,6 72,7 75,5 77,4 79,2 80,7 Wind 7 m/s 59,0 64,0 67,5 71,0 73,9 76,8 79,2 80,5 82,0 Wind 8 m/s 60,5 65,2 68,9 72,6 75,3 78,1 80,9 82,0 83,3 Wind 9 m/s 62,4 66,7 70,4 73,7 76,9 79,6 81,7 83,5 84,8 Wind 10 m/s 62,3 66,5 70,1 73,4 76,4 79,1 81,3 83,0 84,3 V10[m/s] 200Hz 250Hz 315Hz 400Hz 500Hz 630Hz 800Hz 1kHz 1.25kHz Wind 5 m/s 81,6 84,0 85,9 85,7 85,0 85,9 84,1 83,4 81,7 Wind 6 m/s 83,8 85,5 87,5 87,4 86,8 87,5 85,7 84,9 83,2 Wind 7 m/s 85,6 86,4 88,4 88,4 87,8 88,6 86,9 86,1 84,5 Wind 8 m/s 87,1 86,9 89,2 89,2 88,8 89,8 88,2 87,4 85,9 Wind 9 m/s 88,7 87,4 89,7 89,8 89,4 90,5 89,0 88,2 87,0 Wind 10 m/s 88,3 86,9 89,4 89,5 89,1 90,3 89,0 88,2 87,2 V10[m/s] 1.6kHz 2kHz 2.5kHz 3.15kHz 4kHz 5kHz 6.3kHz 8kHz 10kHz 12.5kHz Wind 5 m/s 80,2 81,0 80,1 76,6 76,7 73,4 69,2 65,1 60,4 55,0 Wind 6 m/s 81,5 82,7 81,6 77,8 77,2 73,9 70,4 66,6 62,3 57,0 Wind 7 m/s 82,9 83,9 82,7 78,9 77,8 74,3 70,9 67,1 62,7 57,2 Wind 8 m/s 84,3 85,2 83,7 80,1 78,3 74,7 70,9 67,0 62,4 56,5 Wind 9 m/s 85,5 86,3 84,4 80,9 78,5 74,5 70,2 66,1 60,8 54,6 Wind 10 m/s 86,0 86,6 84,4 81,2 78,4 74,3 69,9 66,0 61,3 55,5 © Copyright Emergya Wind Technologies bv, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. Category: Specification Revision: 00 Title: Sound power level DW54 - 500kW Page 10 / 10 Doc code: S-1005030.docx Appendix 2 measured sound pressure levels Figure 0.1 Measured sound pressure levels 11 November 2011 Figure 0.2 Measured sound pressure levels 15 February 2012 © Copyright Emergya Wind Technologies bv, The Netherlands. Reproduction and/or disclosure to third parties of this document or any part thereof, or use of any information contained therein for purposes other than provided for by this document, is not permitted, except with the prior and express permission of Emergya Wind Technologies BV, The Netherlands. TNEI SUMMARY ANALYSIS OF NOISE DATA FOR : EWT-DW54 500KW-NA blade-Full mode-50hub Turbine identification: Available Noise Document(s) Considered in the analysis of this turbine: Manufacturer: EWT Doc. Date Doc. Name Manufacturer doc: 14/03/2012 S-1005020-R02-1. No hub height is referenced, assumed 50m but need seek clarification. Blade Type/Name: NA Test Report1: 09/05/2012 S-1005030. No hub height is referenced, assumed 50m but need seek clarification. Not an independent report, measurments dated Feb 2012 at the Elbaweg in Ve Operational Mode: Full Test Report2: Model Name: DW54 500KW Hub Height: 50 Test Report3: Summary of Sound Power Levels(LwAeq) at various wind speeds: Wind Speed (standardised 10m) 5 6 7 8 9 10 Manufacturer Lw raw as found in document 2 3 4 97.0 98.0 99.0 100.0 100.5 100.5 Manufacturer specified Lw +Manufacturer Uc+TNEI Uc (used for modeling by TNEI) 100.5 99.0 100.0 101.0 101.5 101.5 11 12 Comment: Summary of Octave Data (LwAeq) used for modelling: Octave data is from Test Report1 at 10m/s Overall Frequency (Hz) 31.5 63 125 250 500 1000 2000 4000 8000 Octave data at 10m/s from raw 1/3 octave or octave 72.2 81.6 87.8 93.1 94.4 93.0 90.5 83.6 71.8 99.5 Octave data at 10m/s adjusted by TNEI to obtain 101.5dB(A) 74.2 83.6 89.8 95.1 96.4 95.0 92.5 85.6 73.8 101.5 Comment: Octave as presented in Table 3.1 at 10m/s Plot of Octave Data Octave data at 10m/s adjusted by TNEI to obtain 101.5dB(A) Sound Power Level (dB(A)) 120 Octave data at 10m/s from raw 1/3 octave or octave 100 80 60 40 20 0 31.5 63 125 250 500 1000 2000 4000 8000 Frequency (Hz) Additional Comment: Data analysed in accordance with the guidance from the IOA GPG May 2013. TNEI-WTDA-NOISE V3.0-EWT-DW54 500KW-NA blade-Full mode-50hub-2013-10-24-MC-GC United Utilities Operational Noise Assessment Proposed Fleetwood Wind Turbine ANNEX 2 - Correspondence with the Environmental Health Department at Wyre Council Page 1 of 3 Gemma Clark From: Jason Baldwin Sent: 23 October 2013 15:17 To: Gemma Clark Subject: Fwd: 7440c-Fleetwood Noise Assessment ---------- Forwarded message ---------From: McArthur, David <David.McArthur@wyre.gov.uk> Date: 20 August 2013 15:39 Subject: RE: 7440c-Fleetwood Noise Assessment To: Jason Baldwin <jason.baldwin@tnei.co.uk> Cc: Matthew Lambert <matthew.lambert@tnei.co.uk> Matthew, I have now refreshed my memory of the details provided and I am happy that the proposed locations are representative. I am not aware of any other schemes in the area that would impact on the monitoring. I may be available to accompany you when the equipment is installed so please let me know when this is planned and I will see what I can do. Regards, David McArthur. David McArthur Environmental Health Officer Wyre Council David.McArthur@wyre.gov.uk 01253 887414 Civic Centre, Breck Road, Poulton-le-Fylde, Lancashire, FY6 7PU The Wyre Council email disclaimer can be found at www.wyre.gov.uk/disclaimer. From: Jason Baldwin [mailto:jason.baldwin@tnei.co.uk] Sent: 15 July 2013 17:54 23/10/2013 Page 2 of 3 To: McArthur, David Cc: Matthew Lambert Subject: 7440c-Fleetwood Noise Assessment Dear Mr McArthur, Following your conversation earlier with my colleague Matt Lambert, I enclose the letter and plan outlining the proposed wind turbine noise assessment at United Utilities Fleetwood site. As discussed, apologies for the short notice but we propose to start background noise monitoring next week and so would be grateful to receive your comments regarding the noise assessment methodology and monitoring locations as soon as you are able. If you require any further information, please do not hesitate to contact either myself on the number below or my colleague Matt Lambert (0191 211 1404). Kind regards, Jason Baldwin Assistant Technical Consultant TNEI Services Limited Tel: +44 (0)191 2111412 Fax: +44 (0)191 2111432 Website: http://www.tnei.co.uk E-mail: jason.baldwin@tnei.co.uk Address: Milburn House, Dean Street, Newcastle upon Tyne, NE1 1LE Registered in England & Wales No. 03891836, Registered office: Chester House, 76-78 Chertsey Road, Woking, United Kingdom, GU21 5BJ -Jason Baldwin Assistant Technical Consultant TNEI Services Limited Tel: +44 (0)191 2111412 Fax: +44 (0)191 2111432 Website: http://www.tnei.co.uk E-mail: jason.baldwin@tnei.co.uk Address: Milburn House, Dean Street, Newcastle upon Tyne, NE1 1LE 23/10/2013 United Utilities Fleetwood - Noise Kit Installation Report Reproduced under Google Earth pro licence Matthew Lambert (TNEI Services Ltd) and David McArthur (EHO, Wyre Council) were in attendance on site to agree locations for noise kit installation on 22nd August 2013. Once access was agreed with the Broadwater Caravan Park a noise kit was installed on the 9th September 2013 by Niall Smith (TNEI Services Ltd). H1- Harbour Village Reproduced from Red Row Homes figure as updated aerial photography not currently available Installation Photographs: H1 – E H1 – S H1 – W H1 – N Location Description Kit installed 22/08/13. The noise kit was placed on the patio area in the rear garden at 25 Windward Avenue. The noise kit was placed in this position due to it being the main amenity area used by the residents, as well as providing a more sheltered position than at the front of the property. The sounds that were audible during the installation were construction noise, distant road traffic as well as occasional local road traffic, model aeroplanes being flown in the vicinity, and birdsong. The noise meter was located in a free field position, greater than 3.5m from any hard reflecting surface except the ground. H2- Laurel Avenue Reproduced under Google Earth pro licence Installation Photographs: H2 – N H2 – S H2 – E H2 – W Location Description Kit installed 22/08/13. This location was included as an additional location to those originally agreed with the EHO at Wyre Council while access to the Broadwater Caravan Park was confirmed. It was considered to be a similar distance from the A585 road as the monitoring location at H4- Broadwater Caravan Park. The noise kit was placed in the patio area of the rear garden at 4 Laurel Avenue which was the main amenity space. The sounds that were audible during the installation were road traffic noise from the A585 road to the east of the property, occasional aircraft noise and a dog barking. The noise meter was located in a free field position, greater than 3.5m from any hard reflecting surface except the ground. Location Description Kit installed 22/08/13. This location was included as an additional location to those originally agreed with the EHO at Wyre Council while access to the Broadwater Caravan Park was confirmed. It was considered to be a similar distance from the A585 road as the monitoring location at H4- Broadwater Caravan Park. The noise kit was placed in the patio area of the rear garden at 4 Laurel Avenue which was the main amenity space. The sounds that were audible during the installation were road traffic noise from the A585 road to the east of the property, occasional aircraft noise and a dog barking. The noise meter was located in a free field position, greater than 3.5m from any hard reflecting surface except the ground. H3- Fairfield Court Reproduced under Google Earth pro licence Installation Photographs: H3 – N H3 – S H3 – E H3 – W Location Description Kit installed 22/08/13. This monitoring location was chosen to be representative of the surrounding residential properties, away from the main road and also to provide a large enough amenity space suitable for kit installtion. The noise kit was placed on the patio on the eastern side of the rear garden at 17 Fairfield Court. The location was considered to be the main amenity area used by the residents. The sounds that were audible during the installation were mainly from road traffic noise (including on the A585). The noise meter was located in a free field position, greater than 3.5m from any hard reflecting surface except the ground. H4- Broadwater Caravan Park Reproduced under Google Earth pro licence Installation Photographs: H4 – N H4 – S H4 – E H4 – W Location Description Kit installed 09/09/13. The monitoring location was chosen to be representative of the background noise environment for the properties at the Caravan Site while not being unduly influenced by road traffic noise compared to some areas of the site which were closer to the main road. The exact position of monitoring equipment was was agreed with the site manager, providing a suitable relatively sheltered noise monitoring location while not also impacting upon caravan park operations. The sounds that were audible during the installation were mainly road traffic noise on the A585 and B5268, as well as rustling foliage, and birdsong. The noise meter was located in a freefield position, greater than 3.5m from any hard reflecting surface except the ground.