Motorised fire protection: Product selection brochure (PDF

advertisement
Fire damper actuators.
Selection and integration.
Motorised fire dampers are shut-off devices that
prevent fire and smoke from spreading through
ventilation systems. In the event of a fire, they
protect people and tangible assets.
Fire dampers are equipped with a thermoelectric
tripping device. To prevent smoke from spreading,
they can also be triggered by smoke detectors.
They are powered by Belimo fire safety actuators.
2
Belimo supplies cost-effective and easy-to-integrate solutions for the motorisation
of fire dampers.
Proven product range.
Simple motorisation solutions.
Belimo safety actuators
for fire dampers
Type
Torque
Dimensioning:
AC / DC 24 V
AC 230 V
5¡
BFG...
6 Nm
4 Nm
18 Nm
12 Nm
11 Nm
8.5 Nm
7 VA
7 VA
10 VA
11 VA
10 VA
11 VA
95°
95°
180°
40...75 s
< 20 s
< 120 s
< 16 s
< 120 s
< 20 s
12 mm (8/10 mm possible)
12 mm (10 mm possible)
10 mm
TABLEAU
1 2 3
M
5¡
Running time
M
Triggering:
• thermal (-T)
• as option via smoke detector
BF...
M
Angle of rotation
Damper rotation / form fit
BLF...
5¡
TABLEAU
1 2 3
TABLEAU
1 2 3
M
5¡
TABLEAU
1 2 3
3
Conventional and digital control
and monitoring.
Conventional control with position feedback
4- to 6-wire
(feedback open/closed provided by auxiliary switches)
2-wire (control open-close)
Automation station
DDC / programmable controller
Control and monitoring via SBS-Control
*
Automation station
DDC / programmable controller
2-wire
(control and feedback)
*
2-wire
(control and feedback)
2
*
2
up to 9 fire dampers
* Optional: smoke detector with potential-free contact
4
Connection to control cabinet
Actuator types
• Cables for motor and auxiliary switches wired directly to control cabinet.
• For 24 V actuators, the voltage drop over long lines should be noted. The voltage at the
actuator must be within the tolerance stated in the data sheet.
• Feedback of damper position by means of auxiliary switches.
Connection to automation station
Communication and control unit
BKS24-1B and plug socket ZSO-11
• For controlling and monitoring of a fire
damper
• 3 LEDs for indicating operating statuses
and faults
• Function test of fire damper actuator
• Potential-free auxiliary
contacts for integration
into system
Communication and control unit
BKS24-9A
Sensors
Communication and
power supply unit
BKN230-24
• Decentralised power
supply unit for 24 V fire
damper actuators
• Local power supply
AC 230 V
-T
Smoke
detector
(optional)
BLF24-T, BLF230-T
BLF24, BLF230
BF24-T, BF230-T
BF24, BF230
BFG24-T, BFG230-T
BFG24, BFG230
Actuator types
BLF24-T-ST
BLF24-ST
BF24-T-ST
BF24-ST
BFG24-T-ST
BFG24-ST
• Integrated LED status
indicator
• Connection for a smoke
detector contact and/or
a thermoelectric tripping
device
• Controls and monitors up to 9 fire
dampers
• LED status display indicating operating
statuses and fault messages
• Function test of fire damper actuators
• Potential-free auxiliary contacts for
integration into system
• Zone control, summarised alarms
5
Control and monitoring
via communicative bus solutions.
Connection
To Modbus RTU via Belimo field unit BKN230-24-MOD
*
Modbus RTU
*
1...64 dampers
* Optional: smoke detector with potential-free contact
To Modbus RTU or BACnet MS/TP via MP-Bus® and Belimo Gateways
*
Modbus RTU / BACnet
*
1...8 dampers
* Optional: smoke detector with potential-free contact
*
* Optional: smoke detector with potential-free contact
*
1...8 dampers
DDC
Ethernet / BACnet /
Profibus etc.
To various protocols via MP-Bus® and DDC controller
LonWorks®
To LonWorks® via gateway from third-party manufacturer**
**Support for gateway is provided by third-party manufacturer
6
Gateways
Connection modules
Communication and
power supply unit
BKN230-24-MOD
Sensors
-T
• Interface to Modbus RTU
• Baud rate up to 76'800 Bd
• Termination can be switched
• Parametrisation
adjustable
via DIL switch
Belimo UK24BAC / UK24MOD
• Interface to BACnet MS/TP or to
Modbus RTU
• Connection of up to 8 fire damper
actuators
• Summary or detailed fault
message for each
fire damper
DDC controller with MP interface
• Belimo provides the MP specifications
to all manufacturers of DDC controllers.
They can use these specifications to
implement own hardware/software
design into their devices.
Direct connection to gateway
• e.g. LonWorks gateway
®
• Star wiring of fire damper actuators
Smoke
Actuator types
BLF24-T-ST
BLF24-ST
BF24-T-ST
BF24-ST
BFG24-T-ST
BFG24-ST
detector
(optional)
Communication and
power supply unit
BKN230-24-C-MP
• Interface to MP-Bus
• Decentralised power
supply unit for 24 V fire
damper actuators
• Local power supply
AC 230 V
• Integrated LED status
indicator
• Connection for a smoke
detector contact and/or a
thermoelectric tripping
device
* BLF24-T, BLF230-T
* BF24-T, BF230-T
* BFG24-T, BFG230-T
*Depending on the gateway,
actuators with plugs can also
be used (..-ST)
7
5-year
warranty
Concept and design: agor ag, Zurich
Korr2013_
On site around
the globe
A complete
range of products
from one source
Tested quality
Short delivery
times
Head office
BELIMO Automation AG
Brunnenbachstrasse 1
CH-8340 Hinwil, Switzerland
Tel. +41 43 843 61 11
Fax +41 43 843 62 68
info@belimo.ch
Belimo worldwide: www.belimo.com
ENG – 05.2013 – 0.5M – Printed in Switzerland – DE Druck – Subject to changes