Fire damper actuators. Selection and integration. Motorised fire dampers are shut-off devices that prevent fire and smoke from spreading through ventilation systems. In the event of a fire, they protect people and tangible assets. Fire dampers are equipped with a thermoelectric tripping device. To prevent smoke from spreading, they can also be triggered by smoke detectors. They are powered by Belimo fire safety actuators. 2 Belimo supplies cost-effective and easy-to-integrate solutions for the motorisation of fire dampers. Proven product range. Simple motorisation solutions. Belimo safety actuators for fire dampers Type Torque Dimensioning: AC / DC 24 V AC 230 V 5¡ BFG... 6 Nm 4 Nm 18 Nm 12 Nm 11 Nm 8.5 Nm 7 VA 7 VA 10 VA 11 VA 10 VA 11 VA 95° 95° 180° 40...75 s < 20 s < 120 s < 16 s < 120 s < 20 s 12 mm (8/10 mm possible) 12 mm (10 mm possible) 10 mm TABLEAU 1 2 3 M 5¡ Running time M Triggering: • thermal (-T) • as option via smoke detector BF... M Angle of rotation Damper rotation / form fit BLF... 5¡ TABLEAU 1 2 3 TABLEAU 1 2 3 M 5¡ TABLEAU 1 2 3 3 Conventional and digital control and monitoring. Conventional control with position feedback 4- to 6-wire (feedback open/closed provided by auxiliary switches) 2-wire (control open-close) Automation station DDC / programmable controller Control and monitoring via SBS-Control * Automation station DDC / programmable controller 2-wire (control and feedback) * 2-wire (control and feedback) 2 * 2 up to 9 fire dampers * Optional: smoke detector with potential-free contact 4 Connection to control cabinet Actuator types • Cables for motor and auxiliary switches wired directly to control cabinet. • For 24 V actuators, the voltage drop over long lines should be noted. The voltage at the actuator must be within the tolerance stated in the data sheet. • Feedback of damper position by means of auxiliary switches. Connection to automation station Communication and control unit BKS24-1B and plug socket ZSO-11 • For controlling and monitoring of a fire damper • 3 LEDs for indicating operating statuses and faults • Function test of fire damper actuator • Potential-free auxiliary contacts for integration into system Communication and control unit BKS24-9A Sensors Communication and power supply unit BKN230-24 • Decentralised power supply unit for 24 V fire damper actuators • Local power supply AC 230 V -T Smoke detector (optional) BLF24-T, BLF230-T BLF24, BLF230 BF24-T, BF230-T BF24, BF230 BFG24-T, BFG230-T BFG24, BFG230 Actuator types BLF24-T-ST BLF24-ST BF24-T-ST BF24-ST BFG24-T-ST BFG24-ST • Integrated LED status indicator • Connection for a smoke detector contact and/or a thermoelectric tripping device • Controls and monitors up to 9 fire dampers • LED status display indicating operating statuses and fault messages • Function test of fire damper actuators • Potential-free auxiliary contacts for integration into system • Zone control, summarised alarms 5 Control and monitoring via communicative bus solutions. Connection To Modbus RTU via Belimo field unit BKN230-24-MOD * Modbus RTU * 1...64 dampers * Optional: smoke detector with potential-free contact To Modbus RTU or BACnet MS/TP via MP-Bus® and Belimo Gateways * Modbus RTU / BACnet * 1...8 dampers * Optional: smoke detector with potential-free contact * * Optional: smoke detector with potential-free contact * 1...8 dampers DDC Ethernet / BACnet / Profibus etc. To various protocols via MP-Bus® and DDC controller LonWorks® To LonWorks® via gateway from third-party manufacturer** **Support for gateway is provided by third-party manufacturer 6 Gateways Connection modules Communication and power supply unit BKN230-24-MOD Sensors -T • Interface to Modbus RTU • Baud rate up to 76'800 Bd • Termination can be switched • Parametrisation adjustable via DIL switch Belimo UK24BAC / UK24MOD • Interface to BACnet MS/TP or to Modbus RTU • Connection of up to 8 fire damper actuators • Summary or detailed fault message for each fire damper DDC controller with MP interface • Belimo provides the MP specifications to all manufacturers of DDC controllers. They can use these specifications to implement own hardware/software design into their devices. Direct connection to gateway • e.g. LonWorks gateway ® • Star wiring of fire damper actuators Smoke Actuator types BLF24-T-ST BLF24-ST BF24-T-ST BF24-ST BFG24-T-ST BFG24-ST detector (optional) Communication and power supply unit BKN230-24-C-MP • Interface to MP-Bus • Decentralised power supply unit for 24 V fire damper actuators • Local power supply AC 230 V • Integrated LED status indicator • Connection for a smoke detector contact and/or a thermoelectric tripping device * BLF24-T, BLF230-T * BF24-T, BF230-T * BFG24-T, BFG230-T *Depending on the gateway, actuators with plugs can also be used (..-ST) 7 5-year warranty Concept and design: agor ag, Zurich Korr2013_ On site around the globe A complete range of products from one source Tested quality Short delivery times Head office BELIMO Automation AG Brunnenbachstrasse 1 CH-8340 Hinwil, Switzerland Tel. +41 43 843 61 11 Fax +41 43 843 62 68 info@belimo.ch Belimo worldwide: www.belimo.com ENG – 05.2013 – 0.5M – Printed in Switzerland – DE Druck – Subject to changes Comprehensive support