Pricing Guide
2700PL9201R09/13
2013
Class 2700/2705/2741/2742
QED-2
OEM Interiors MDS
CONTENTS
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page
Masterpact™ and PowerPact™ Circuit Breaker Options and Accessories. . . . . 8
Individually Mounted Circuit Breakers–Main or Branch
Group Mounted I-Line™ Circuit Breakers–Main or Branch. . . . . . . . . . . . . . . . .15–18
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
2
Class 2741/2742
This pricing guide contains pricing information for all factory-assembled Square D™ brand QED-2 switchboards and
OEM Interiors, and Schneider Electric Multi-Distribution Switchboards (MDS).
NOTE: Features that are not applicable to the Canada market are shown with a gray tint in the pricing procedure.
All other items are for both the U.S. and Canada markets
Square D™ brand QED-2 switchboards consist of one or more switchboard sections with standard depths of 24 in. to
60 in. All QED components listed in this pricing procedure can be placed in factory-assembled switchboards.
Schneider Electric assembly plants reserve the right to arrange the switchboard and components in the minimum number of sections and with the minimum necessary bussing, in accordance with Schneider Electric’s standard engineering practices and applicable industry standards. If additions are requested, it will be necessary to charge for the additional sections.
Underwriters’ Laboratories (UL) Listing: A UL label is no charge on standard switchboards when every device contained therein is UL Listed or recognized. The bussing and the enclosure must be constructed according to UL 891
Dead-front Switchboard Standards. Since each switchboard must be UL labeled individually, i nform your assembly plant when a UL/CSA service entrance or UL dead-front section label is specified .
QED-2 and MDS switchboards are designed and tested in accordance with CSA C22.2 No. 31.
NOTE: Do not use this estimating procedure in conjunction with any other procedure, unless the other estimating procedure specifically authorizes the use of Low Voltage Switchboard Pricing Guide SW-2. For items not listed, or when in doubt, contact your local assembly plant.
QED-2 and MDS Switchboard Section Layout
To determine the correct number of switchboard sections, use the inches of mounting height of the devices. This height correlates with the device height, bussing, and required space for UL Listing. Total all the metering and main inches and determine the number of sections. Then total all the branch distribution inches and determine the quantity of sections.
For information on layout, refer to Catalog #2700CT1101, Power-Style Low Voltage Switchboards and
Catalog #S2705CT1301BP R0, Multi-Distribution Switchboards .
Metric Conversion Factors
• Inches (in.) x 25.4 = millimeters (mm).
• Square inches (sq. in.; in.
2 ) x 45.16 = square millimeters (mm 2 )
• Cubic inches (cu. in.; in.
3 ) x 16.387 = cubic centimeters (cc; cm 3 )
• Pound inches (lb. in.) x 0.113 = Newton meters (N•m)
3 © 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Utility Metering
Class 2741/2742
Service Entrance (SE) Requirements (SE Label)
Switchboards used as service entrance equipment include a UL SE label, main bonding jumper, neutral disconnect link, ground bus, grounding lug, and barriers. Price per number of mains.
Mains Type
Individually mounted mains
Group mounted mains
List Price
(per section)
$ 1410.
1410.
NOTE: In main-tie-main applications, two individually mounted breakers are $2809. List Price.
Current Transformer (CT) Compartments–EUSERC and Non-EUSERC
Prices are for a complete CT compartment which conforms to basic utility requirements. Price includes single door,
through bus. An auxiliary section charge is required if no through bus. Contact your local Technical Assistance Group
(TAG) for specific utility requirements.
System 800 A 1200 A 2000 A 2500 A 3000 A 4000 A
5000 A
3W
4W
$ 7377.
9836.
$ 12741.
16988.
$ 12741.
16988.
$ 14270.
19026.
$ 17123.
22831.
$ 22774.
30365.
$ 28467.
37956.
NOTES: Double door is available for no additional charge.
For Schneider Electric-supplied CTs, price from the Customer Metering table on page 6.
In the U.S., a PT mounting provision is $1,346.
List Price.
Mounting Height
Middle
45 in.
45 in.
Top or
Bottom
36 in.
36 in.
EUSERC (Western) CT Compartment In Combination With Main Circuit Breaker or Main Switch
Canada Utility Compartments
Canada
CT
Provision
PT
Provision
System 800 A 1200 A 2000 A 2500 A 3000 A 4000 A
5000 A
BC Hydro
Brampton
Hydro One
Hydro Quebec
Mississiauga
Saskatoon
Toronto Hydro
Other
MV-7 (Standard Bar Type)
MV-7 (1P 3W) (Dual Bar Type)
R6MC (Window Type)
R6L (Window Type)
JAK-0 (Window Type)
JAD-0 (Window Type)
Unknown (if the CT type is not known)
Available
3W $ 7377.
$ 12741.
$ 12741.
$ 14270.
$ 17123.
$ 22774.
$ 28467.
4W 9836.
16988.
16988.
19026.
22831.
30365.
37956.
a Only single main is allowed in Canada. For Canadian main-tie-main applications, please contact your local Technical Assistance Group (TAG).
b Requires full-height section (except EUSERC compartment).
c Some utilities in Canada require ground studs. Pricing is $4,240 .
d Does not require full-height section.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
4
Square D™ Brand
QED-2 Switchboards
Incoming Connections
Class 2741/2742
Lineside Lug Connection–Distribution and Six Disconnect Mains
A lineside lug connection charge is required when lugs or studs are required to feed the vertical bus of a I-Line™ or
QMB section with or without through bus. A line side connection charge is not required for single main devices, whether
auxiliary section ahead of the line-up will have a Section Charge and a Lineside Lug or Stud Connection Charge.
System 400 A 600 A 800 A 1000 A 1200 A 1600 A 2000 A 2500 A 3000 A 3200 A 4000 A 5000 A 6000 A 7000 A 8000 A
3W or
4W
$2120.
$2120.
$2120.
$3180.
$3180.
$4240.
$5300.
$6360.
$7420.
$8480.
$8480.
$10600.
$12720.
$14840.
$16960.
24 in.
24 in.
24 in.
24 in.
24 in.
24 in.
24 in.
30 in.
36 in.
42 in.
42 in.
48 in.
54 in.
54 in.
54 in.
Qwik-Flange Connection/Riser Bus
Aluminum
System
3W
4W
Copper
System
3W
4W
600 A
$ 4092.
4982.
600 A
$ 4717.
5756.
800 A
$ 5088.
6212.
800 A
$ 6074.
7409.
1000 A
$ 5554.
6784.
1000 A
$ 6710.
8162.
1200 A
$ 6498.
7908.
1600 A
$ 7272.
8872.
2000 A
$ 9752.
11904.
1200 A
$ 7950.
9710.
1600 A
$ 9487.
11586.
2000 A
$ 11416.
13907.
2500 A
$ 10924.
13335.
3000 A
$ 12222.
14893.
4000 A
$ 15147.
18486.
5000 A
—
—
2500 A
$ 13017.
15868.
3000 A
$ 14745.
17988.
4000 A
$ 19250.
23479.
5000 A
$ 25981.
31694.
Aluminum
System
3W
4W
Copper
System
3W
4W
600 A
$ 5152.
6042.
600 A
$ 5777.
6816.
800 A
$ 6148.
7272.
800 A
$ 7134.
8469.
1000 A
$ 6614.
7844.
1200 A
$ 7558.
8968.
1600 A
$ 8332.
9932.
2000 A
$ 10812.
12964.
1000 A
$ 7770.
9222.
1200 A
$ 9010.
10770.
1600 A
$ 10547.
12646.
2000 A
$ 12476.
14967.
2500 A
$ 11989.
14385.
3000 A
$ 13282.
15953.
4000 A
$ 16207.
19546.
5000 A
—
—
2500 A
$ 10477.
16928.
3000 A
$ 15805.
19048.
4000 A
$ 20310.
24539.
5000 A
$ 27041.
32754.
Transformer Throat/Vault Stub
Aluminum
System
3W
4W
Copper
System
3W
4W
600 A
$ 6445.
7346.
600 A
$ 7070.
8109.
800 A
$ 7452.
8565.
800 A
$ 8427.
9763.
1000 A
$ 7908.
9127.
1000 A
$ 9063.
10526.
1200 A
$ 8851.
10261.
1600 A
$ 9625.
11225.
2000 A
$ 12116.
14257.
2500 A
$ 13292.
15688.
3000 A
$ 14575.
17246.
4000 A
$ 17501.
20840.
5000 A
$ 22811.
27316.
6000 A
—
—
1200 A
$ 10314.
12063.
1600 A
$ 11840.
13939.
2000 A
$ 13769.
16271.
2500 A
$ 15370.
18221.
3000 A
$ 17108.
20341.
4000 A
$ 21603.
25832.
5000 A
$ 28334.
34047.
6000 A
$ 38255.
48007.
a Width of bussed auxiliary section.
b Qwik-Flange available on NEMA Type 1 top feed only.
c NEMA Type 1 bottom feed and NEMA Type 3R require a flanged-end connection. The flanged-end connection is sprinkler resistant.
d Vault stub is used in Canada.
5
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Customer Metering
Class 2741/2742
Power Monitoring And Control
Power Meter
Class
3020
3020
3020
Type
PM-820
PM-850
PM-870
Description
Power Meter Module with Display 0.25% Accuracy w/ Logging, Alarms, I/O Modules
Same as PM-820 plus Trending/Forecasting, Steady State Waveform Capture
Same as PM-850 plus Disturbance Waveform Capture, Sag/Swell Metering
List Price
$ 18465.
24804.
29250.
Circuit Monitors
Class
3020
3020
3020
Type
CMDLC
CMDVF
CM4000T
Description
Liquid Crystal Display used for both Circuit Monitors
Upgrade to Vacuum Fluorescent Display with Infrared Port
Same as CM4250 plus Transient Voltage Monitoring, Flicker IEC 61000-4-15
Input/Output Modules
Class
3020
3020
3020
3020
3020
Type Description
IOC44
IOX2411
IOX0404
IOX08
I/O Card w/4 status in, 3 relay out and 1 KYZ out
I/O Extender Module w/4 DC status inputs, and 2 DC digital outputs, 1 analog output
I/O Extender Module w/4 status inputs and 4 analog inputs
I/O Extender Module w/8 Status Inputs (120 Vac)
IOX I/O Extender Module Only, No Installed I/O
PM8M2222 2 digital outputs, 2 digital inputs, 2 analog outputs, and 2 analog inputs
PM8M26
PM822
2 digital outputs and 6 digital inputs
2 digital outputs and 2 digital inputs
List Price
N/C
$ 4240.
58406.
List Price
$ 4007.
7738.
10759.
4463.
2989.
3646.
3275.
2809.
ION 7550/7650 Meters
Catalog No.
S7550A0C0B6A0A0A
S7550A0C0B6E0A0A
S7650A0C0B6A0A0A
S7650A0C0B6E0A0A
S7650A0C0B6C1A0A
S7650B1C0B6C1A0A
Description
Basic unit: Integrated display, instrumentation, power quality, waveform capture, one RS232/RS485 port, one RS-485 jack, one Type 2 optical port, eight digital inputs, four digital outputs, and three onboard relays
Basic unit plus Ethernet
Basic unit plus additional ION7650 features
Basic unit plus Ethernet and additional ION7650 features
Basic unit plus Ethernet, internal modem, and additional ION7650 features
Basic unit plus Ethernet, 1,024 samples/cycle instead of 512, 10 MB of logging instead of 5 MB, internal modem, and additional ION7650 features
List Price
$ 35934.
47435.
42824.
54325.
54325.
69907.
Communications Network Options
Type Description
No Web Pages
Device Web Pages
Modbus RS-485 Communications Wired Out
Modbus Repeater
(per line-up)—required for comms with H-, J-, or L-frame PowerPact with Modbus RS-485 wired out
Modbus TCP—Ethernet Copper with Ethernet Communications Card (ECC) and PM8 or CM4 family of meters
Modbus TCP—Ethernet Gateway (EGX300). Up to 31 devices per network per line-up. For more than 31 devices, add up to two slave networks with an EGX100 gateway for a maximum of 90 communicating devices per line-up.
Ethernet Gateway (EGX100)
Customer Ethernet Network
100Base-T Fiber HUB System
100Base-T Copper HUB System
List Price
No charge
$ 996.
11501.
27984.
13992.
10939.
6148.
a No PTs required through 600 Vac.
b Required for pulse initiator/sync pulse input application.
c Modbus repeater is a separate adder per line-up.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
6
Square D™ Brand
QED-2 Switchboards
Customer Metering
Class 2741/2742
Instrument Transformer Requirements a
Device
1PH3W
120/240 V
3PH3W
Delta or Wye
Circuit Monitor
Power Meter
Ion Meter
2 CTs
2 CTs
2 CTs, 2 PTs
2 CTs, 1 CPT
2 CTs, 1 CPT
,
3 PTs
Potential Transformer (PT)
Item
Control Power Transformer (CPT)
Fused voltage taps wired to terminals for remote PM
Potential Transformer
208Y/120
3 CTs
3 CTs
3 CTs
List Price Each
$ 890.
1200.
2957.
3PH4W
Wye
Delta
480Y/277 600Y/347
3 CTs 3 CTs, 1 CPT 3 CTs
3 CTs 3 CTs 3 CTs
3 CTs, 1 CPT, 3 PTs 3 CTs, 1 CPT, 3 PTs 3 CTs, 1 CPT, 3 PTs
Current Transformer (CT)
Rating
800 A
1600 A
2500 A
3000 A
4000 A
5000 A
Window, Each
$ 1590.
3074.
3434.
3593.
3805.
5141.
Window, x2
List Price
$ 3180.
6148.
6869.
7187.
7611.
10282.
a Drawout circuit breakers require three CTs for all voltages.
b CPT is not required for 240 V Delta.
Window, x3
$ 4770.
9222.
10303.
10780.
11416.
15423.
Bar, Each
$ 2523.
3901.
4251.
4738.
5576.
7515.
7
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Circuit Breaker Options and Accessories
Class 2741/2742
Energy
Trip Unit Options
PowerPact P and R, and
Masterpact NW Electronic Trip
Circuit Breakers
Standard
LI
(3.0)
LSI
(5.0)
LI
(3.0A)
Ammeter
LSI
(5.0A)
LSIG
(6.0A)
No charge
$ 1670.
$ 3180.
$ 4670.
$ 9430.
—
—
—
Power
LSI
(5.0P)
LSIG
(6.0P)
Harmonic
LSI
(5.0H)
LSIG
(6.0H)
— $ 21600.
$ 31000.
$ 32330.
$ 37000.
Trip Unit Options
PowerPact L-frame Electronic Trip
Circuit Breakers
PowerPact J-frame Electronic Trip
Circuit Breakers
PowerPact H-frame Electronic Trip
Circuit Breakers
Standard
LI (3.3)
LSI
(3.3S)
No charge
No charge
No charge
$ 1670.
785.
549.
—
—
—
—
Ammeter
LSI (5.0)
LSIG
(5.3A)
LSI
Energy
(5.3A)
LSIG
(6.3E)
$ 4670.
$ 9430.
$ 7659.
$ 13777.
3643.
6538.
4978.
8542.
2550.
4577.
3485.
5979.
—
—
—
—
Power
—
—
—
—
—
—
—
Harmonic
—
— —
—
—
ZSI- Adder for Wiring
Short-time
Ground Fault
Short time and Ground Fault
—
—
—
Standard
—
—
—
—
—
—
Ammeter Energy
Communications (Modbus RS485 Wired Out)
Circuit Breaker
Circuit breaker prepared space (for PowerPact H, J, and L circuit breakers with Ammeter or Energy trip units)
Cradle (For Masterpact NW only; standard with circuit breaker communications)
Power Harmonic
$ 1357.
$ 1357.
$ 1357.
$ 1357.
$ 1357.
$ 1357.
$ 1357.
$ 1357.
— 1357.
— 1357.
— 1357.
— 1357.
— 2174.
— 2174.
— 2174.
— 2174.
List Price Each
$ 4296.
—
4296.
Common Accessories—For Ammeter/Energy/Power/Harmonic Electronic Trip Unit
Front Display Module (FDM121) Installation on individually mounted and group mounted devices
Front Display Module (FDM121) Installation for V > 480 Vac
PowerPact test kit (full function) for NW, P, and R
PowerPact test Kit (mini function) for NW, P, and R
Pocket Tester (mini function) for H, J, and L
UTA Tester (full function) for H, J, and L
Control Power
24 Vdc Power Supply for trip unit power. Required for H trip unit, recommended for A and P trip units.
External voltage source wired to line side of circuit breaker (used to power the trip unit)
Control Power transformer (only one required per vertical section, or one per line-up for Series 2 designs)
$ 4560.
8194.
22324.
4470.
1430.
23380.
$ 1950.
1166.
890.
Maximum Number of FDMs Per I-Line 63 in., Full-Height Section
Switchboard Configuration
Single Row
Double Row
Switchboard Width
(Inches)
36
42
48
36
42
48
54
Circuit Breaker Frame Size
(Amps)
3000
2000
2500
3000
1200
1600
2000
1200
1600
2000
1200
1600
2000
2000
2500
3000
1200
1600
2000
2500
3000
2000
2500
Wide Side
12
12
12
12
12
12
12
12
12
12
12
8
8
8
12
12
12
12
12
12
12
12
12
FDM Locations
Narrow Side
8
8
8
8
8
—
—
—
—
8
8
8
8
8
8
8
—
—
—
—
—
—
— a Only available for installation on 63 in. full height single- and double-row, I-Line interiors. Not available for combo I-Line interiors. The maximum number of FDMs per section is shown in the chart above.
b 14 FDMs are possible with these switchboard widths, but the placement will be non-symmetrical.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
8
Square D™ Brand
QED-2 Switchboards
Masterpact (Stored Energy) Circuit Breakers—UL 489
Class 2741/2742
Masterpact low voltage, molded case circuit breakers contain a two-step stored energy mechanism which provides
5-cycle maximum closing in both manually and electrically-operated types. The Standard trip units come with LI functionality: long-time ampere rating, long-time delay adjustments, and instantaneous trip. See page
for trip unit options price adders. Prices include neutral CT for 3Ø4W systems. Short-time, ground fault protection and circuit breaker accessories may be added to the standard circuit breaker price when required. All standard Masterpact circuit breakers are UL489 Listed and are 100% rated. 4-pole circuit breakers can be priced by multiplying the stationary or drawout pricing by 1.2.
NOTE: Space and mounting provisions include same features as above except for the circuit breaker.
Circuit
Breaker
Model
Frame Size
(Amperes)
Breaker Type
AC Interrupting Rating
RMS Sym. Amperes (in thousands)
NW
800
1600
2000
2500
3000
4000
5000
WL7
WL1
WL3
WL7
WL1
WL3
WL7
YL1
WL1
WL3
WL7
WL1
WL3
WL7
WL1
WL3
YL7
YL1
YL3
YL7
YL3
YL7
YL1
YL3 a For 6000 A in U.S. or Canada, contact your local TAG.
240 V
65
100
200
65
200
65
100
200
100
200
65
100
65
100
200
65
200
65
100
200
100
200
65
100
480 V
65
100
150
65
150
65
100
150
100
150
65
100
65
100
150
65
150
65
100
150
100
150
65
100
600 V
50
85
100
50
100
50
85
100
85
100
50
85
50
85
100
50
100
50
85
100
85
100
50
85
Manually Operated,
Stationary Mounted
List Price
Manually Operated,
Drawout Mounted
Standard LI Future Space Standard LI Future Space
$ 49163.
53403.
—
56477.
60717.
—
71412.
75652.
—
87885.
95305.
—
98697.
106117.
—
Use ANSI
Use ANSI
—
277932.
277932.
—
—
290846.
—
$ 9826.
11480.
15020.
23935.
Use ANSI
31270.
—
$ 13123.
15105.
20002.
30115.
36157.
41298.
—
$ 77984.
82224.
86464.
88976.
93216.
97456.
107558.
111798.
116038.
128631.
136051.
140291.
146545.
153965.
158205.
220014.
236974.
241214.
414926.
414926.
419166.
—
427858.
419166.
9
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Masterpact (Stored Energy) Circuit Breakers—UL 1066
Class 2741/2742
Masterpact Low Voltage circuit breakers are available as a single main, double-ended main, or tie, rated to 5000 A @
600 Vac. The trip units are the same as the Masterpact UL 489 circuit breaker.
ANSI rated circuit breakers are 100% rated and contain a two-step stored energy mechanism which provides 5-cycle maximum closing in both manually and electrically-operated types. The Standard trip units come with LI functionality: long-time ampere rating, long-time delay adjustments, and instantaneous trip. See page
adders. When ground fault is required on a 4-wire system, the price includes a neutral CT. Other features available on the circuit breaker include short-time, ground fault protection, motor operation and may be added to the standard circuit breaker price.
NOTE: Space and mounting provisions include same features as above except for the circuit breaker.
Circuit
Breaker
Model
Frame Size
(Amperes)
Breaker Type
AC Interrupting Rating
RMS Sym. Amperes (in thousands)
NW
800
1600
2000
3200
4000
5000
YA4
YA5
YA6
YA8
WA4
WA5
WA6
WA8
YA4
WA5
WA6
YA8
WA6
WA8
WA4
WA5
WA6
WA8
WA2
WA4
WA5
WA6
WA8
WA2
WA4
WA5 a Use L1F breakers for applications requiring reduced fault let through.
240 V
100
200
65
85
100
200
100
200
65
85
200
200
65
85
200
65
85
100
65
85
100
200
42
65
85
100
200
200
42
480 V
100
200
65
85
100
200
100
200
65
85
200
200
65
85
200
65
85
100
65
85
100
200
42
65
85
100
200
200
42
600 V
85
130
65
85
85
130
85
130
65
85
130
130
65
85
130
65
85
85
65
85
85
130
42
65
85
85
130
130
42
List Price
Manually Operated,
Stationary Mounted
Manually Operated,
Drawout Mounted
Standard LI Future Space Standard LI Future Space
—
—
109763.
117183.
117183.
—
157951.
174911.
174911.
—
288998.
288998.
288998.
—
$ 60229.
60229.
64469.
64469.
—
—
67543.
67543.
71783.
71783.
—
—
82479.
86719.
86719.
$ 9826.
11480.
23935.
27390.
31270.
$ 13123.
15105.
30115.
—
36157.
—
41298.
—
127105.
139816.
157611.
165031.
165031.
169271.
231080.
248040.
248040.
252280.
425993.
425993.
425993.
430233.
$ 89051.
89051.
93291.
93291.
97531.
107284.
100043.
100043.
104283.
104283.
108523.
119375.
118625.
122865.
122865.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
10
Square D™ Brand
QED-2 Switchboards
Accessory
Auxiliary Switches: 4a-4b
Auxiliary Switches: 8a-8b
Auxiliary Switches: 12a-12b
Overcurrent Trip Switch 1a/1b contact (SDE)
2 Programmable Contact Module Form C (Power and Harmonic Trip Units only)
6 Programmable Contact Module Form C (Power and Harmonic Trip Units only). Required for Ground Fault No-Trip.
Cover over Open/Close buttons
Cover over front of circuit breaker (transparent)
Contact Wear Indication
Visual Indication
Software Indication (requires Circuit Breaker Communication Module with PowerLogic system software)
Electric Reset or 2nd Overcurrent Trip Switch
Ground Fault Alarm Indication and Contacts (For Ground Fault No-Trip, requires Programmable Contact Module)
Audible Indication
Visual Indication
Audible and Visual Indication
Neutral Protection NW/YL
Operation Counter
Padlock Provisions on Cradle
Ready-To-Close 1a/1b Contact
Key Interlock (per lock)
Key Interlock Provisions (per lock). Customer supplies lock.
Shunt Close without communications
Shunt Close with communications
Shunt Trip without communications. (120 Vac only for QED-S)
Shunt Trip without communications
Shunt Trip with communications
2nd Shunt Trip without communications
Undervoltage Trip, Instantaneous
Undervoltage Trip, Adjustable Time Delay
Undervoltage Trip, Non-Adjustable time Delay
Spring Charging Motor (includes provisions for Open and Close capability, but not control power or indicating lights)
Temperature Indication (requires Circuit Breaker Communication Module with PowerLogic system software)
Waveform Capture (requires Circuit Breaker Communication Module with PowerLogic system software)
Drawout Circuit Breaker Cradle Accessories
Cradle Shutters
Cradle Shutter Padlock Provisions
Cradle Shutter Indicator
Cradle Position Switches
1a/1b Form C (Connected/Test/Disconnected)
Padlock Provisions on Cradle
Schneider Electric Cradle Key Interlock
Circuit Breaker Lifting and Transport Truck (Floor Crane)
Circuit Breaker Lifting Trolley for Entire Switchboard (indoor top of switchboard mounting; requires 18 in. above switchboard)
Masterpact NW Drawout Stored Energy Remote Racking Device Mounting Provisions
Masterpact NW Remote Racking Operator Kit
Zone Selective Interlocking Interface
120 Vac source required. On multiple main systems, one RIM is required for each tie breaker in the system.
Drawout Crank (comes with Masterpact circuit breaker)
Phase Failure with Capacitor Trip (requires 120 Vac Shunt Trip)
Masterpact Accessories
Class 2741/2742
List Price
Standard
$ 3604.
5406.
Standard
1251.
5003.
212.
392.
Standard
P and H Trip Units
1887.
445.
445.
890.
1696. /3392.
859.
Standard
1802.
2237.
636.
1802.
2226.
1802.
2226.
2226.
1802.
1908.
1972.
1808.
13123.
P and H Trip Units
P and H Trip Units
986.
159.
318.
1378.
Standard
2237.
16621.
12879.
640.
89900.
3403.
Standard
11289.
11
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Trip
Rating
(Amps)
Main or Branch Circuit Breakers
Class 2741/2742
Molded Case Circuit Breakers–Individually Mounted
Price includes individually mounted main or branch molded case circuit breakers, mounting of circuit breakers, mounting pan, loadside connectors (on mains), lineside connectors to vertical bus (on branches), and card holders. On branch, loadside connectors’ lugs point vertical. Space for future circuit breaker includes the same features as above, but does not include the circuit breaker. For stacked devices, price each device separately, including accessories.
Circuit Breaker
Frame Size
(Amps)
AC Interrupting Rating
RMS Symmetrical Amperes
(in thousands)
List Price
800
1200
MG
MJ
PG
PK
PJ
PL
240 V
65
100
65
65
100
125
480 V
35
65
35
50
65
100
600 V
18
25
18
50
25
—
300–600
700–800
300–600
700–800
600–800
1000–1200
600–800
1000–1200
600–800
1000–1200
600–800
1000–1200
3-Pole
$ 13589.
18338.
16663.
21423.
18790.
19891.
20992.
22093.
23194.
24295.
25396.
26497.
2-Pole
$ 11671.
15179.
14043.
18592.
15673.
16982.
18291.
19600.
20909.
22218.
23527.
24836.
Space for Each
Future Breaker
$ 6795.
Circuit Breaker
Frame Size
(Amps)
2500
Type
RG
RK
RJ
RL
65
65
100
125
AC Interrupting Rating
RMS Sym. Amps
(in thousands)
50
65
65
100
42
65
25
65
Trip
Rating
(Amps)
1400–1600
2000
2500
1400–1600
2000
2500
1400–1600
2000
2500
1400–1600
2000
2500
List Price
Each Breaker
3-Pole
$ 31007.
34514.
37906.
36263.
45453.
49619.
32733.
42644.
47170.
39771.
48262.
52067.
2-Pole
$ 26475.
30486.
33030.
32171.
37545.
45442.
29320.
35150.
44022.
35022.
39930.
46863.
Space for Each
Future Breaker
$ 7674.
8766.
7674.
8766.
7674.
8766.
7674.
8766.
Emergency Disconnect
Use F, H, J, L frame price from I-Line (page 16), and multiply by 1.6.
Accessories
Accessory
Shunt Trip
Undervoltage Trip
Auxiliary Switches
1A and 1B
2A and 2B
3A and 3B
Alarm Switch
M, P, R
Key Interlock (Kirk type)
Cylinder Lock
Electrical Operator (do not use for transfer schemes)
PG, PK, PJ, PL
Phase Failure with Capacitor Trip
Padlock Attachment for PowerPact M, P, R a Refer to layout manual for stacked devices.
b PC 2500 A bottom mount only.
List Price
$ 1198.
1198.
466.
647.
848.
466.
1897.
636.
5703.
11289.
32.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
12
Square D™ Brand
QED-2 Switchboards
13
Main or Branch Circuit Breakers
Class 2741/2742
PowerPact with Micrologic Electronic Trip Molded Case Circuit Breakers–Individually Mounted
Prices include individually mounted solid-state molded case circuit breakers with standard Micrologic™ electronic trip units. Long-time ampere rating, long-time delay adjustments, and instantaneous trip (LI) are standard on full function.
Long-time ampere rating, long-time delay adjustments, short-time, short-time delay adjustments, and instantaneous trip are standard on limited function. Circuit breakers may also be ordered with integral ground fault, which comes standard with a neutral CT for 4W systems and integral ground fault indicator. Interchangeable rating plugs can be changed without removing cover. integral ground fault test feature standard on ground fault equipped circuit breakers for testing the ground fault system per NEC Section 230-95. A 120 V power source is required, either external to or inside the switchboard. Remember to include size of rating plug required. For further information, refer to the Digest™.
Sensor
Size
(Amps)
%
Rated
Type
240 V
AC Interrupting Rating
RMS Symmetrical Amperes
(in thousands)
480 V 600 V
List Price (includes rating plug)
Standard LI
3-Pole 2-Pole
Space for Each
Future Breaker
250–400
450–600
700–800
1000–1200
1600
2000
2500
100
80
100
80
100
80
100
80
100
80
100
80
80
100
80
100
80
100
80
100
100
80
100
80
100
80
100
100
80
100
80
100
80
100
80
80
100
80
100
80
100
80
100
80
100
80
100
80
100
80
100
80
100
80
100
80
RJ
RJ-C
RL
RL-C
RG
RG-C
RK
RK-C
RJ
RJ-C
RL
RL-C
RJ
RJ-C
RL
RL-C
RG
RG-C
RK
RK-C
PJ-C
PL
PL-C
RG
RG-C
RK
RK-C
PJ-C
PL
PL-C
PG
PG-C
PK
PK-C
PJ
PL
PL-C
PG
PG-C
PK
PK-C
PJ
PL-C
PG
PG-C
PK
PK-C
PJ
PJ-C
PG
PG-C
PK
PK-C
PJ
PJ-C
PL
65
65
100
125
65
65
100
125
65
65
100
125
65
65
100
125
65
65
100
125
65
65
100
125
65
65
100
125
35
50
65
100
35
50
65
100
35
50
65
100
35
50
65
100
35
65
65
100
35
65
65
100
35
65
65
100
18
50
25
—
18
50
25
—
18
50
25
—
18
50
25
—
18
65
25
50
18
65
25
50
18
65
25
50
34821.
42040.
39337.
46555.
44414.
52025.
47170.
73553.
47170.
73553.
51686.
78069.
35838.
29871.
40725.
23702.
31312.
26458.
39782.
26458.
39782.
30973.
44297.
32065.
39676.
34821.
42040.
19238.
22295.
19552.
22860.
19886.
23426.
20220.
23992.
20554.
24558.
20356.
27753.
23132.
31537.
26286.
$ 17059.
18334.
17373.
18900.
17687.
19466.
18002.
20032.
18316.
20597.
18630.
21163.
18924.
21729.
28461.
35680.
32977.
40195.
35935.
45665.
40810.
67193.
40810.
67193.
45326.
71709.
28670.
22136.
32580.
15222.
22832.
17978.
31302.
17978.
31302.
22493.
35817.
25705.
33316.
28461.
35680.
16160.
18551.
16424.
19006.
16704.
19462.
16985.
19918.
17265.
20374.
15077.
22202.
17507.
25230.
20029.
$ 14330.
15399.
14593.
15815.
14857.
16271.
15122.
16727.
15385.
17183.
15649.
17639.
15896.
18095.
$ 6795.
7674.
8766.
8766.
Trip Unit
LI
LS
LSI
LIG
LSG
LSIG
Option
LI
LS
LS
LIG
LSG
LSG
Circuit Breaker Trip Unit
Price Adder
Standard
$ 4950.
4950.
4950.
9900.
9900.
A
—
—
—
$ 4950.
4950.
4950.
Definitions
A =Ground fault alarm only.
1. Local Indication using RIM32, Aromat Relay, CPT, Pilot light or
2. Using PowerLogic for remote indication.
ZI=Short-time and ground fault zone selective interlocking, wired.
Z2=Short-time zone selective interlocking only, wired.
Z3=Ground fault zone selective interlocking only, wired.
Z1
—
—
—
—
$ 2714.
2714.
Z2
—
$ 1357.
1357.
—
1357.
1357.
Z3
—
—
—
$ 1357.
1357.
1357.
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Main or Branch Circuit Breakers
Class 2741/2742
PowerPact with Micrologic Electronic Trip Molded Case Circuit Breakers–Individually Mounted
Accessories
Auxiliary Contacts:
(1a+1b Form C) $ 466.
(2a+2b Form C)
(3a+3b Form C)
647.
848.
Alarm Switch:
(1a+1b Form C) $ 466.
Overcurrent Trip Switch:
(1a+1b Form C) $ 466.
Shunt Trip:
120 Vac Shunt Trip
Shunt Trip w/Communications
$ 1198.
2226.
6 Programmable Contact Module Form C (Power and Harmonic Trip Units Only)
Extra Control Power Transformer (only one required per vertical section)
Electrical Operators (PowerPact P-frame only; do not use for transfer schemes)
Ground Fault Alarm Indication and Contacts (For Ground Fault No-Trip, requires Programmable Contact Module)
$ 5003.
890.
5703.
Audible and Visual Indication
Ground Fault Push-To-Test Feature factory wired for 120 Vac
Universal Test Set
Phase Failure and Capacitor Trip
Padlock Attachment for PowerPact P- and/or R-frame
Key Interlock Provisions with Lock (price is per lock)
Undervoltage Trip non ADJ
Undervoltage Trip ADJ
445.
445.
890.
890.
12784.
11289.
32.
201.
1897.
1198.
1261.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
14
Square D™ Brand
QED-2 Switchboards
Group Mounted I-Line Interiors
Class 2741/2742
Interior Pricing (Interior pricing only; price main, structure, and CIC separately)
List Price
Al Cu
27
36
36E
63
S2736
D2736
D2742
D2748
2000
2000
2000
2000
S3636
D3642
1000
1000
D3648 1000
S3636E
2000
D3642E
D3648E
1200
2000
42
48
S63XX16 1600 36, 42, 48
S63XX16 1600 42, 48, 54
S63XX20 2000 36, 42, 48
S63XX20 2000 42, 48, 54
S63XX25 2500 36, 42, 48
S63XX25 2500 42, 48, 54
36
42
48
36
36
36
42
48
S63XX30 3000 36, 42, 48
S63XX30 3000 42, 48, 54
D6336
D6342
2000
2000
36
42
D6348
D6354
2000
3000
48
54
R
R
R
R
R
R
P
R
P
P
P
L
L
P
P
K
R
R
K or Q
L
R
R
—
F
J w.o. GF
J w/out GF or Q
—
J w/out GF
27
27
J w/out GF or Q 27
— 36
18
18
18
18
J w/out GF or Q 36
J w/out GF or Q 36
—
—
63
63
—
—
—
—
63
63
63
63
—
—
F
J
J
J
63
63
54
54
54
63
63
63
63
63
72
72
63
63
27
63
63
36
18
45
45
45
63
63
117
117
117
108
0
0
0
0
36
36
0
0
0
36
36
0
0
27
27
27
63
63
0
0
63
45
A
—
A
—
—
—
A
—
—
—
—
—
S
S
S
S
A
A
A
A
A
—
A
—
A
—
S
S
A
—
—
—
—
S
—
—
—
—
A
A
A
A
A
—
A
—
A
—
S
S
A
—
—
—
—
S
—
—
—
—
A
A
A
A
A
—
A
S
A
S
A
S
—
—
—
—
—
S
—
—
—
—
A
A
A
S
A
A
A
—
A
—
—
S
A
—
—
—
—
S
—
—
—
—
A
A
A
A
A
—
A
—
A
—
—
—
A
—
S
S
S
—
—
—
—
—
A
A
A
A
A
—
No
No
No
No
Yes
Yes
No
No
No
No
No
Yes
No
No
No
No
No
No
No
No
No
No
—
—
—
—
—
—
—
—
9L
9L
9L
—
9L
9L
9L
9L
—
—
9L
9L
9L
R18
7858.
12821.
10000.
10000.
11667.
11667.
14175.
14175.
$ 5850
5875.
5875.
5875.
6271.
7441.
7441.
12721.
15435.
15435.
12051.
14040.
17550.
23526.
7858.
12821.
4244.
4244.
8337.
8337.
8625.
8625.
$ 2133.
2731.
2731.
2731.
3105.
4281.
4281.
6810.
15435.
15435.
6435.
7605.
11700.
23526.
a Combination sections are not available in Canada.
b Only Combo interior to allow placement of up to four H-, J-, or L-frame PowerPact with Micrologic 5/6 trip units for LSIG applications.
c CIC Main Lugs available in same section as 63 in., full height, single row interior or in adjacent auxiliary section with through bus.
NOTES:
• Additional section width on 63 in., full height, single row interiors to allow for optional lugs on feeder circuit breakers and for customer metering in CIC
(main lug) sections.
•
• CIC = Common incoming connector (Main Lugs)
• 36E = End Fed Interior
• S = Same Section (Combo Section)
• A = Adjacent Section
• — = Not available
15
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Back-fed Main or Feeder Circuit Breakers
Class 2741/2742
I-Line Group Mounted Molded Case Circuit Breakers
Price includes molded case circuit breakers arranged in group mounted I-Line construction. Maximum ampacity of
Mag-Gard™ circuit breakers are not available in switchboard I-Line construction.
Thermal Magnetic and Basic Electronic Trip
Frame
FA
FA
HD
QB
JD
LA
FH
HG
QD
QG
JG
LH
MJ (Basic Electronic)
PJ (Basic Electronic)
PK (Basic Electronic)
HJ
HL
JJ
JL
JR
I-Line C/B
MG (Basic Electronic)
PG (Basic Electronic)
%
Rated
80
Amps
Range
15–70
15–60
70–100
15–60
70–100
110–150
70–225
70–225
150–225
250
70–225
125–400
300–400
450–600
700–800
600–1200
600–1200
15–60
70–100
110–150
15–60
70–100
110–150
150–225
250
150–225
250
150–225
250
600–1200
15–60
70–100
15–60
70–100
15–60
70–100
15–60
70–100
110–150
70–225
150–225
250
125–400
300–400
450–600
700–800
600–1200
600 V
—
—
—
—
14
—
14
22
18
18
—
18
—
—
18
—
25
50
25
50
25
50
100
PL (Basic Electronic) 50 a Not available for use on 480 Delta rated systems b 208Y/120 systems only
480 V
—
—
—
—
18
—
18
30
35
35
—
25
35
—
—
35
—
35
65
50
65
100
65
100
200
100
SCCR (X 1000)
277 V
—
—
18
—
18
—
—
—
—
35
—
25
35
—
—
35
—
35
65
—
65
100
65
100
200
100
240 V
10
18
25
10
25
42
65
65
65
65
25
65
65
100
65
100
65
100
125
100
125
200
125
120 V
10
18
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
10
—
—
—
—
—
—
3-P
4.5
—
—
4.5
6
9
—
4.5
6
9
9
4.5
4.5
9
Height (In,)
2-P
3
—
—
3
4.5
6
9
—
3
4.5
3
6
9
9
4.5
4.5
9
List Prices
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1-P
1.5
3-P 2-P
$ 678.
$ 488.
912.
689.
1081.
774.
1124.
943.
1102.
869.
1325.
1049.
1717.
1442.
1950.
1717.
3053.
2396.
1844.
615.
3159.
2523.
5067.
4176.
5311.
4314.
6837.
5311.
8809.
6837.
11035.
8851.
20161.
18317.
— —
1696.
1484.
1738.
1611.
2120.
1717.
2735.
1929.
4134.
3625.
2396.
1410.
3604.
3498.
4569.
3604.
5618.
4452.
4198.
3922.
5724.
5512.
11194.
8968.
11830.
9222.
14384.
10950.
21582.
19398.
24051.
21624.
2332.
2120.
2862.
2512.
5024.
4431.
4240.
3498.
4378.
3689.
7102.
5936.
6604.
5883.
8374.
7208.
7759.
6466.
9116.
7526.
11576.
9261.
14548.
11639.
26511.
23824.
—
—
—
—
—
—
—
—
—
—
—
—
—
1.5
1.5
—
—
—
—
—
—
—
—
—
1-P
—
—
—
—
—
700.
572.
636.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
$ 265.
392.
371.
424.
—
—
—
—
—
—
—
—
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
16
Square D™ Brand
QED-2 Switchboards
Back-fed Main or Feeder Circuit Breakers
Class 2741/2742
Electronic Trip—Standard and Advanced
I-Line Circuit Breaker
Frame
%
Rated
HD
HG
HJ
HL
HR
JD
JG
JJ
JL
JR
LD
LG
LJ
LL
LR
LD-C
LG-C
LK-C
LL-C
LR-C
PG
RG-C
PK
PJ
LXI
PL
PG-C
PK-C
RK-C
PJ-C
RJ-C
PL-C
RL-C
80
100
80
100
80
100
Ampere
Range
700–800
1000–1200
1000–1200
250–400
450–600
700–800
600–1200
250–400
450–600
700–800
100–250
160–400
240–600
250–400
450–600
700–800
250–400
125–400
200–600
70–250
125–400
200–600
70–250
125–400
70–250
125–400
70–250
125–400
70–250
125–400
70–250
125–400
250–400
450–600
450–600
700–800
250–400
450–600
700–800
600–1200
250–400
450–600
700–800
1000–1200
250–400
450–600
700–800
1000–1200
35–100
50–150
70–250
70–250
70–250
70–250
70–250
70–250
125–400
200–600
70–250
125–400
200–600
70–250
125–400
200–600
70–250
15–60
35–100
50–150
15–60
35–100
50–150
15–60
35–100
50–150
15–60
35–100
50–150
15–60
600 V
14
18
25
50
100
18
25
50
100
25
18
50
25
100
50
18
50
65
25
50
14
18
25
50
100
14
14
18
50
100
SCCR (X 1000)
480 V 277 V 240 V
18
35
65
100
200
18
35
65
100
200
18
35
65
100
200
18
35
65
100
200
35
50
65
200
100
35
50
65
65
100
25
65
100
125
200
65
100
125
200
25
65
100
125
200
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
25
65
100
125
200
25
25
65
100
200
200
25
65
100
25
65
100
125
200
25
65
100
125
200
125
200
65
65
100
200
125
65
65
65
100
125
120 V
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3-P
4.5
6
9
15
9
9
7.5
15
9
9
9
15
9
15
9
15
Height (in.)
2-P
4.5
6
9
15
9
9
7.5
15
9
9
9
15
9
15
9
15
List Price
3-P 2-P
10724
12738
12332
12332
14649
6292
6292
6604
6604
10778
10778
12547
12547
8622
8622
10037
10037
14429
14429
11543
11543
$10462.
$ 8374.
13441.
10770.
8579
10191
9866
9866
11719
5034
5034
5284
5284
15783.
12635.
22313.
17850.
25928.
20755.
13780.
11035.
16759.
13420.
19101.
15285.
27369.
21868.
11522.
9222.
14501.
11618.
16843.
13483.
17554.
14490.
22186.
19303.
33008.
29277.
16038.
12847.
19016.
15222.
21359.
17087.
12370.
9900.
7775
5645
5645
8167
9212
9212
11378
10724
5968
12520
4013
5082
7231
9381
13133
5378
5378
1790
2102
3756
2110
2380
4848
2703
2898
6895
4027
4263
8943
5638
15561.
12466.
17691.
14162.
16472.
13176.
19557.
15656.
21794.
17437.
31429.
25154.
13430.
10748.
16621.
13314.
18751.
15010.
28313.
22663.
19504.
15603.
22483.
17999.
24825.
19684.
34535.
27645.
6220
4516
4516
6534
7369
7369
9102
8579
4774
10016
3210
4065
5784
7505
10506
4302
4302
1432
1682
3005
1688
1904
3878
2162
2318
5516
3222
3410
7154
4510
1-P
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1-P
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
17
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Back-fed Main or Feeder Circuit Breakers
Class 2741/2742
PowerPact with Micrologic Trip Mission Critical Circuit Breakers
I-Line Circuit Breaker
Frame % Rated
JD
JG
JJ
JL
LD
LG
LJ
LL
80
Ampere
Range
125–400
200–600
70–250
125–400
200–600
70–250
125–400
200–600
70–250
70–250
70–250
70–250
70–250
125–400
200–600
70–250
600 V
14
18
25
50
14
18
25
50
480 V
18
35
65
100
SCCR (x 1000)
277 V
25
65
100
125
240 V
25
65
100
125
18
35
65
100
25
65
100
125
25
65
100
125
120 V
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3-P
4.5
6
Height (in.)
2-P
4.5
6
1-P
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
List Price
2-P
4516.
6534.
7369.
7369.
9102.
8579.
8579.
10191.
—
—
—
—
4302.
4302.
6220.
4516.
3-P
6989.
9959.
11191.
11191.
13744.
12973.
12973.
18577.
$ 4655.
5844.
8246.
10650.
6675.
6675.
9497.
6989.
1-P
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
The following branch circuit breakers are available on Canada I-Line.
QO Adapter—240 Vac, 30 A Max. Branch Circuit Breakers
Number of Poles Mounting Height (in.) Catalog No.
HQO206AB
HQO206BC
HQO206AC
HQO306
2
3
4.5
QO Plug-On Circuit Breakers
Amps Range Frame
QO
QO-VH
QH
15–30
KAIC @ 240 V
10
22
65
1-Pole
$ 19.40
42.30
78.00
List Price
2-Pole
$ 44.70
97.00
195.00
List Price
$ 1476.
3-Pole
$ 165.00
247.00
338.00
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
18
Square D™ Brand
QED-2 Switchboards
Item
Undervoltage release
Overcurrent Trip Switch
Phase Monitor and Capacitor Trip
Universal test set (LE,ME,NE / P,R)
120 Vac shunt trip
F,H,J,K,L
M,N,P,R
List Price
$ 1198.
466.
11289.
12784. / 22324.
647.
1198.
Auxiliary Contacts
Type List Price
(1A + 1B)
(2A + 2B)
(3A + 3B)
$ 466.
647.
848.
Accessories
Class 2741/2742
Alarm Switch
Type List Price
F,H,J,K,L
M,N,P,R
$ 276.
488.
Item
6 Programmable contact module
Mechanical interlock between two circuit breakers, (reference Class 2110 for restrictions), 3 in. of mounting space
Key interlock, Schneider Electric: Requires 3 inches of mounting space for all circuit breakers except F, H, J, L, M, P, R
Motor operators: Available for FA/FH, LA/LH. Each motor operator requires 4.5 in. mounting height.
Available for HD/HG/HJ/HL, JD/JG/JJ/JL thermal magnetic breakers. Does not require additional mounting height.
FA/FH, HD/HG/HJ/HL, JD/JG/JJ/JL (Do not use motor-operated circuit breakers for transfer schemes.)
LA/LH (Do not use motor-operated circuit breakers for transfer schemes.)
PG/PJ/PL motor operators require no additional mounting space
Plug-on HQO distribution panel (maximum voltage 240 Vac)
Add-on ground fault module for FA,/FH,/FC/FI, HD/HG/HJ/HL, JD/JG/JJ/JL circuit breakers; requires one CPT per vertical section.
Price includes shunt trip.
(Space only. Includes ground fault sensor for frame selected)
L, M, P, R ground fault space only. Includes sensor for appropriate circuit breaker
Padlock attachment for Q, H, J, M, P, R
Cylinder lock available on FA, LA circuit breakers
Undervoltage trip. Supply drops to a value between 35%–70%
Undervoltage trip with time delay adjustable, 0.5, 0.9, 1.5, 3.0 seconds
List Price
$ 5003.
1569.
1897.
3795.
1272.
3275.
4123.
4717.
297.
4484.
297.
668.
32.
636.
1198.
1802.
Blank Extensions and Fillers
Required for all circuit breakers 250 A frame and below to cover the open space between the circuit breaker and front cover. Blanks extensions and fillers are included at $0 List Price when required for factory assembled line-ups.
Application
PowerPact H- or J-frame circuit breakers with Micrologic 5/6 trip units
PowerPact H- or J-frame circuit breakers with Micrologic 5/6 trip units
All other circuit breakers frames, 250 A and below
All other circuit breakers frames, 250 A and below
Blank Fillers—for future space
Circuit Breaker Mounting Height
4.5 in.
4.5 in.
1.5 in.
4.5 in.
1.5 in.
4.5 in.
1.5 in.
4.5 in.
I-Line Interior Mounting Side
Narrow Side
Wide Side
Narrow Side
Narrow Side
Wide Side
Wide Side
Either
Either
Catalog Number
HLN4EBL
HLW4EBL
HLN1BL
HLN4BL
HLW1BL
HLW4BL
HNM1BL
HNM4BL
19
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Bolt-Loc™ Switches—Main or Branch
Class 2741/2742
Price includes bolted pressure contact, single throw, 100% rated, load break switch with dead front operating handle, fuse compartment hinged door, card holder, and connections to main bus. Fuses are not included.
Bolt-Loc Type BP switches are suitable for use on circuits capable of delivering 200,000 rms symmetrical amperes when used with
NEMA Class L fuses. Space mounting charges include the same features as above, except do not include the switches or operating handles. All switches are quick-make quick-break.
Switch
Type
Bolt-Loc
Type BP
List Price Each (600 Vac Maximum, 2- or 3-Pole)
Switch
Rating
(Amperes)
Standard Feed Inverted Feed
Manual Electric
GFP
Manual Electric
800 A
1200 A
1600 A
2000 A
$ 24168.
$ 30051.
$ 43555.
$ 27221.
$ 35976.
$ 46608.
27624.
33507.
47011.
30676.
39432.
50064.
29903.
35786.
49290.
32955.
41711.
52343.
38202.
44085.
60197.
41255.
50011.
63250.
2500 A
3000 A
44393
73500.
50276.
79383.
68783.
97891.
47466.
76553.
56201.
85309.
71836.
102396.
4000 A 96693.
102576.
122536.
99746.
108502.
125589.
116028.
121911.
141870.
119080.
127836.
144923.
Space and
Mounting
Provisions
For Future
Switch
$ 8724.
9657.
11777.
14374.
16727.
26383.
33687.
36750.
Mid.
45
45
72
Mounting Height
(in.)
Top
36
N/A
N/A
Bottom
36
45
72
NOTE: When stacking two switches in a section, the switches are maximum of 800 A top/2000 A bottom, and the top switch must be priced as an inverted feed.
Fusible Switch Accessories
Item List Price
Electric trip (requires either Control Power Transformer priced from below or 120 Vac external power)
Control Power Transformer
Capacitor Trip Power Supply, Class 9810. (Eliminates need for separate control source. Price Electric Trip above; Control Power
Transformer not required.) Add
Blown Main Fuse Detector (requires electric Trip and a 120V power source for Tripping Switch)
2501 Phase Monitor: Trip on all three above with trip on loss of all phases.
Key Interlock (Kirk type), each switch, add
(For Main-Tie-Main, price 6 Interlocks - 2 for Main 1, 2 for tie, 2 for Main 2)
$ 5883.
890.
2714.
1654.
Phase Monitor (Protects three-phase power systems or individual motors from operating under conditions of voltage imbalance (adj.), low voltage (adj.), phase reversal. Adjustable trip time delay standard. Use electric trip or GFP price with capacitor trip for tripping BOLT-LOC (add price from above).
2500 Phase Monitor: Trip on all three above except no trip on loss of all phases, most commonly used.
8575.
8575.
1897.
Unfused Switch (Not UL Listed, unless used as a tie switch)
Auxiliary Switch:
1 NO + 1 NC
2 NO + 2 NC
No Deduct
1092.
1304.
Zone Selective Interlocking Interface (120 V source required; one RIM 32 required per each 25 SE, PE, NE, ME, or LE to GC-100 combination)
Ground Fault Push-To-Test Feature (With and Without Trip) factory wired for 120 Vac
Padlock Attachment
No Charge
No Charge
3403.
NEMA Class L Fuses (Installed)
Ampere
Rating
601–1200 A
1201–1600 A
1601–2000 A
2001–3000 A
3001–4000 A
4001–5000 A
Qty.
3
3
3
3
3
3
KRP-C
List Price
$ 5756.
6487.
7823.
13738.
18730.
29987.
KTU
$ 7250.
9763.
12752.
—
—
— a UL procedure does not exist for dc ratings; therefore, no UL label available for this section.
b Refer to layout manual (Class 2741 or Class 2742) for stacked BP devices.
c GFP is ground fault protection. Price includes zero sequence Type GC ground fault, electric trip, and control power transformer.
d For ground fault applications involving competitor products, or for systems with greater than 3 disconnects, contact your local assembly plant for special pricing.
e 3000A can be mounted in same section as 45 in. high CT compartment, but not with circuit monitor metering.
f UL procedure does not exist above 4000 A; therefore, no UL label is available for this section with ANY manufacturer’s fusible switch.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
20
Square D™ Brand
QED-2 Switchboards
Group Mounted—Fusible Switches
Class 2741/2742
Prices include quick-make quick-break QMB units arranged in group construction, mounting of switches, and mounting pan. Short circuit rating of QMB switches and panel is equal to the lowest fuse interrupting rating to be installed in the switches. Fuses are not included.
DC ratings available on 2-pole switches only. For dc short circuit current rating, contact the fuse manufacturers.
Fully Prepared Space includes all of the necessary hardware and connectors to mount a QMB/J fusible switch.
A twin fusible switch equipped with a blank cannot be equipped with a fusible switch in the future.
Switch
Type
Twin
Switch
Single
Switch
Ampere
Rating
30 A–30 A
30 A–Blank
30 A–60 A
30 A–100 A
60 A–60 A
60 A–Blank
60 A–100 A
100 A–100 A
100 A–Blank
200 A–200 A
200 A–Blank
200 A
400 A
600 A
800 A
1200 A
240 Vac/250 Vdc Maximum
3-Pole
$ 2427.
1823.
—
—
2427.
1823.
—
3085.
2321.
3530.
5258.
11543.
$ 1632.
1230.
—
—
1632.
1230.
—
2449.
1844.
7407.
4357.
3000.
3297.
5120.
9816.
16356.
Class H, J, R or L Fuse Provisions
List Price
2-Pole
Fully
Prepared
Space
QMB
Size
(in.)
QMJ
Size
(in.)
$ 382.
4.5
382.
— — —
— —
382.
382.
—
636.
636.
636.
636.
763.
1272.
1272.
1272.
2035.
—
6
6
—
—
9
15
15
15
24
—
6
—
6
15
15
24
6
7.5
—
—
9
600 Vac/250 Vdc Maximum
3-Pole
$ 3487.
2618.
2427.
3085.
3487.
2618.
3085.
5088.
3583.
4357.
8406.
15476.
$ 2968.
2226.
2427.
3085.
2968.
2226.
3085.
4323.
3254.
7407.
4357.
3710.
7144.
8215.
13155.
16356.
Class H, J, R or L Fuse Provisions
List Price
2-Pole
Fully
Prepared
Space
QMB
Size
(in.)
$ 382.
4.5
382.
4.5
1823.
6
2321.
7.5
636.
6
636.
6
2321.
7.5
636.
7.5
636.
7.5
—
9
763.
1272.
1272.
2035.
9
15
15
15
24
QMJ
Size
(in.)
7.5
—
—
9
6
7.5
6
6
15
15
24
4.5
4.5
6
7.5
6
21
Switch
Type
Ampere
Rating
Single Switch
400 A
600 A
601–800 A
240 Vac/250 Vdc Max.
Class H, R, or L
Fuse Provisions
List Price
600 Vac/250 Vdc Max.
Class H, J, R or L
Fuse Provisions
List Price
3-Pole
$ 6180.
15730.
2-Pole
$ 3869.
5894.
13373.
3-Pole
$ 9869.
11119.
21083.
2-Pole
$ 8385.
9445.
17925.
Size
(in.)
25.5
25.5
25.5
Top
Feed
46.5
46.5
46.5
Feeder
Mounting
(in.)
Bottom
Feed
45
45
45
Key Interlock for 100–800 A $1897. Add 3 in. to each switch, except 100 A, which requires 9 in.
Electrical Interlocks $530. For 30–100 A feeder switches or 200 A Class J feeder switches.
Group Mounted—QMB
Interior Pricing (Interior pricing only. Price main and structure separately.)
Optional Fuses
Installed
(Qty. = 3)
Class L
KRP-C
—
—
$ 5756.
KTU
—
—
$ 7250.
Combination or Full
Combo
Full
Interior
Height
30
63
63
72
Maximum
Ampacity
2000
2000
2500
2000
Section
Width (in.)
36
42
36
42
36
42
48
36
42
48
400
800
400
1200
400
1200
(2) 1200
400
1200
(2) 1200
Maximum
Switch
IMD BP Main
CIC
(Main Lug or
Through Bus
)
Utility
Compartment
(UCT)
A
A
S
S
A
A
A
A
A
A
—
—
—
—
—
—
—
—
—
—
—
—
A
A
A
A
A
A
A
A
Al
List Price
$ 5,167.
5167.
4900.
4900.
5100.
5100.
6700.
5600.
5600.
12400.
Cu
List Price
$ 5167.
5167.
6825.
6825.
7213.
7213.
9375.
7800.
7800.
12400.
3000 a Use 600 Vac size for QMB with Class J fuse provisions.
b Use QMB twin switches.
c Available only in a QMJ switch.
d 100,000 A short circuit current rating with Class R fuses to 600 Vac.
e 1200 A is a branch switch or group mounted six disconnect main with Class L fuses. This switch is suitable for use on systems to 600 Vac maximum at
100,000 A rms. A single main switch 1200 A must be a Bolt-Loc.
f Available on non-service entrance switchboards in Canada.
g CIC Main Lugs available in same section as 63 in., full height, single row interior or in adjacent auxiliary section with through bus.
NOTES:
• CIC = Common incoming connector (Main Lugs)
• S = Same Section (Combo Section)
• A = Adjacent Section
• — = Not available
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Group Mounted—Fusible Switches
Class 2741/2742
Group Mounted—QMQB (Canada Only)
QMQB Interior—Cu $ 10494.
Switch Type Ampere Rating
Twin switch
Single Switch
30A-30A
60A-60A
100A-100A
200A
400A
600A
800A
1200A a If top exit size is 42.625 in., then bottom exit size is 52.25 in.
600 Vac/250 Vdc Maximum
Class H, J, R, or L Fuse Provisions
3-Pole
$ 3487.
3487.
5088.
4357.
80406.
9657.
15476.
19250.
List Price
Fully Prepared Space
—
—
—
—
—
—
—
—
QMQB Size (in.)
5.5
5.5
5.5
9.65
16.5
16.5
19.25
9
3
91.50
(2324)
1.50
(38)
72.875
42.00
(1067)
74.25
3.75
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
22
Square D™ Brand
QED-2 Switchboards
Commercial Multi-Metering
Class 2741/2742
EUSERC structures are available in either three-socket or six-socket configurations. Lever bypass structures are available in a three-socket configuration only. Tenant mains can be circuit breaker or fusible pullout. Standard arrangement is for bottom cable exit, or top cable exit using the built-in loadside wireway. Rear wireway is not available
for these structures. For pricing of meter sockets and disconnects, refer to page 24.
Tenant Main Structure
Volts Structure Ampacity
6-Socket
Section
List Price
120/240,
208Y/120,
240/120, or
480Y/277
Circuit
Breaker or
Fusible
400 A
600 A
800 A
1200 A
1600 A
2000 A
2500 A
3000 A
4000 A
3-Socket Section
Al List Price
$ 4982.
5088.
5406.
6148.
7102.
7685.
9381.
—
10653.
Cu List Price
$ 6678.
6784.
7102.
8321.
9222.
10282.
12296.
14310.
14840.
Refer to QED
Section Charge
EUSERC
DWG 306
M
EUSERC DWG 306
M M
91.50
(2324)
M
M
91.50
(2324)
M M
M M
91.50
(2324)
M
M
M
91.50
(2324)
M
M
M
1.50
(38) 24.00
(610)
EUSERC 3-Socket Section
1.50
(38) 36.00
(914)
EUSERC 6-Socket Section
1.50
(38) 24.00
(610)
1.50
(38) 24.00
(610)
Lever Bypass 3-Socket Section
Hot Sequence Cold Sequence
Loadside and Rear Wireway for Large Tenant Mains (Top Exit of Load Conductors)
Item
Bus Material
Maximum
Ampacity
List Price
Loadside Wireway — Bussed
Loadside Wireway — Non-Bussed
12 in.
24 in.
12 in.
24 in.
N/A
Al
Cu
Al
Cu
N/A
2500 A
1200 A
2500 A
1200 A
2500 A
4000 A
N/A
$ 4500.
6075.
5495.
10335.
8376.
12572.
18200.
3300.
5300.
3409.
a 12 in. wide loadside wireway is available for NEMA Type 1 enclosures only. For NEMA Type 3R enclosures, use 24 in wide loadside wireway.
b 400–2500 A adds 12 in. to depth of structure. For 3000 A and 4000 A, there is no change to depth. Available for NEMA Type 1 enclosures only. For NEMA Type 3R enclosures, select loadside wireway.
23
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Commercial Multi-Metering
Class 2741/2742
Meter sockets are self-contained, 200 A maximum, and contain lugs for both lineside and loadside terminations. Tenant main disconnect is either circuit breaker or class T fusible pullout, 200 A maximum. EUSERC meter sockets are ring-type for use on 240/120 V, 208Y/120 V, and 480Y/277 V, 3Ø4W; or 120/240 V, 1Ø3W. Non-EUSERC or Lever
Bypass meter sockets are ringless-type for use on 480Y/277 V, 3Ø4W only.
EUSERC Meter Socket with Test Block Lever Bypass Meter Socket
Volts Poles
3 Phase
List Price
1 Phase
240/120,
208Y/120, or 480Y/277
ABC $ 2279.
120/240 or
208Y/1‘20
AB
BC
AC
—
Tenant Main Disconnects—Circuit Breaker
—
$ 1908.
Volts
480Y/277
Poles
ABC
3 Phase LIst Price
$ 3180.
Volts
240/120,
120/240, or
208Y/120
480Y/277
SCCR
22 kA
42 kA
65 kA
100 kA
18 kA
35 kA
65 kA
100 kA
Amps
60–100 A
110–200 A
60–100 A
110–200 A
60–100 A
110–200 A
60–100 A
110–200 A
60–100 A
110–200 A
60–100 A
110–200 A
60–100 A
110–200 A
60–100 A
110–200 A
Standard
Breaker Frame
FAL
QDL, HDL
FHL
QGL, HGL, JGL
FHL
QGL, HGL, JGL
QJL, HJL
QJL, HJL, JJL
FAL
HDL, JDL
HGL
HGL, JGL
HJL
HJL, JJL
HLL, JLL
HLL, JLL
List Price
3-Pole
1219.
2947.
2290.
4463.
2703.
6784.
4505.
7632.
$ 1219.
2947.
1632.
2947.
1632.
4463.
2290.
6784.
2-Pole
$ 943.
2290.
1505.
2290.
1505.
4357.
1887.
5777.
N/A
NOTES: Optional breakers can be selected and will be priced according to the frame price listed in the Lever Bypass Meter Socket table above.
For cold sequence CMM: if line and load disconnect are required, both disconnects will need to be priced. Fusible pullouts are not available for the line side disconnect.
Circuit Breaker Trip Ratings
Tenant Main without Disconnect—Cabled to Terminal
Block
Maximum Frame
Trip Ratings
480Y/277
200 A
110, 125, 150, 175, 200
Tenant Main Disconnects—Fusible Pullout
Fusible pullouts use 300 V Class T fuses at 240 V, and
600 V Class T fuses at 480Y/277 V. Fuses are not included.
Volts
240/120,
120/240, or
208Y/120
100 A
60, 70, 80, 90, 100
SCCR
100 k
Amps
70–100 A
110–200 A
35–60 A
70–100 A
110–200 A
3-Pole List Price
$ 1410.
2544.
2046.
2046.
3710.
Volts
All
SCCR
N/A
Amps
60 A
100 A
200 A
List Price
$ 424.
424.
424.
a Single phase units are for use on 240/120 V or 208Y/120 V systems
(208Y/120 V systems require balanced loads).
b Provides a meter socket cover with cutout(s) for meter and a test block cover.
c For circuit breakers with shunt trip, add $922 . List Price. Indicate at order entry that shunt trip is required. Contact your local Schneider
Electric representative for delivery.
d
Price meter socket from the EUSERC Meter Socket with Test Block or
Lever Bypass Meter Socket tables above.
24
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
(Canada Only)
MQS Interior—Cu $ 10494.
Maximum Volts
600 Vac
250 Vdc
Amps
30–30
60-60
100-100
200
Max. Wire Size Catalog No.
(1) #6 Cu/Al
(1) #2 Cu/Al
MQS7-3336S
MQS7-6636S
(1) #1/0 Cu/Al MQS7-1136S
(1) 250MCM Cu/Al MQS7-2036S
Branch Height
9.625 in.
Fuse Type
J, T
Commercial Multi-Metering
Class 2741/2742
Poles
3
List Price
$ 6503.
6527.
6840.
8284.
12.25
(311)
3.875
(98)
91.50
(2324)
1.50
(38)
67.375
(1711)
42.00
(1067)
9.625
(244)
9.625
(244)
70.125
(1781)
3.75
(95)
25
PE1
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
SPD
Class 2741/2742
Standard Features
• Circuit breaker disconnect
• Copper internal bus for the SPD
• Individually fused suppression modes
• UL 1449 Recognized
• On-line diagnostics continuously monitor unit
• Thermal cut-out
• Solid-state bidirectional
• Front panel alarm with test/silence switch
• Front panel operational indicators (LED) to indicate loss of protection or circuit fully operational including N-G
• High energy parallel design for Category A, B, and C3 applications
• AC tacking filter with EMI/RFI filtering up to -50dB from 100 kHZ to 100 MHz
System Voltage
(Vac)
120/240 1P3W
208Y/120 3P4W
240/120 3P4W
480Y/277 3P4W
600Y/347 3P4W
100 kA
$ 18908.
19750.
19750.
20602.
—
100
200 kA
$ 20416.
21260.
21260.
22110.
23000.
100 kA
$ 20088.
20984.
20984.
21898.
—
120
200 kA
$ 21692.
22588.
22588.
23492.
24438.
List Price
Surge Current Capacity (kA per phase)
160
SCCR
100 kA
$ 23634.
24688.
24688.
25752.
—
200 kA
$ 25520.
26574.
26574.
27638.
28750.
100 kA
$ 29354.
30740.
30740.
32130.
—
200
200 kA
$ 30958.
32342.
32342.
33734.
35198.
100 kA
$ 34534.
36164.
36164.
37800.
—
240
200 kA
$ 36420.
38050.
38050.
39686.
41400.
System Voltage
(Vac)
120/240 1P3W
208Y/120 3P4W
240/120 3P4W
480Y/277 3P4W
600Y/347 3P4W
100 kA
$ 18908.
14310.
19750.
15410.
—
100
200 kA
$ 20416.
21260.
21260.
22110.
23000.
100 kA
$ 20088.
15654.
20984.
16754.
—
120
200 kA
$ 21692.
22588.
22588.
23492.
24438.
Surge Current Capacity (kA per phase)
100 kA
$ 23634.
18586.
24688.
19686.
—
160
SCCR
200 kA
$ 25520.
26574.
26574.
27638.
28750.
100 kA
$ 19196.
23596.
23596.
26896.
26896.
200
200 kA
$ 30958.
32342.
32342.
33734.
35198.
100 kA
$ 23760.
27440.
27440.
31460.
31460.
240
200 kA
$ 36420.
38050.
38050.
39686.
41400.
Factory Installed SPD in Switchboards Metering Compartment
(Vac)
120/240 1P3W
208Y/120 3P4W
240/120 3P4W
480Y/277 3P4W
600Y/347 3P4W
100
$ 16017.
18349.
18349.
19515.
19515.
120
$ 17448.
19780.
19780.
20946.
20946.
Surge Current Capacity (kA per phase)
160 200 240
$ 30553.
22885.
22885.
24051.
24051.
200 kA SCCR
$ 23532.
28196.
28196.
31694.
31694.
$ 28366.
32266.
32266.
36528.
36528.
SPD Options
Option
Dry Contacts
Surge Counter
Remote Monitor
List Price
Standard
Standard
$ 2588.
a Requires 13.5 in. of mounting height. Includes line-to-ground protection.
b Not available on 3Ø3W systems.
c Requires 9.0 in. of mounting height. Includes line-to-ground protection.
d Requires 19.5 in. of mounting height. Includes line-to-ground protection.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
320
$ 34948.
38913.
38913.
40895.
40895.
480
$ 48230.
54855.
54855.
62105.
62105.
26
Square D™ Brand
QED-2 Switchboards
Automatic Transfer Switches
Class 2741/2742
1000
1200
1600
2000
3000
4000
30
70
100
150
260
400
600
800
NOTE: Please contact your local TAG to order automatic transfer switches.
Because of the complexity of automatic transfer switches, use careful consideration in the application, layout, and pricing of this product. The following information is required by the TAG at your local assembly plant to process your request for pricing and layout of automatic transfer switches:
1.
Complete specifications for the automatic transfer switch
2.
Front elevation and one-line of the switchboard
3.
A copy of your takeoff and pricing (quote number, item), less the requested product pricing
4.
If applicable, the manufacturer name and location, all necessary ratings, and catalog number(s) of the existing with which the automatic transfer switch is electrically connected.
Automatic Transfer Switches (Per UL 1008)
Switch
Rating
(Amperes)
Mounting Height
(in.)
Middle
Top or
Bottom
36
72
72
72
72
48
48
66
66
72
72
27
63
63
72
72
39
39
57
57
72
72
When Used With Current Limiting Fuses
Class J, RK1, and L Types
Withstand Rating
(RMS Symmetrical
@ 480 Vac Max.)
100,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
Maximum
Fuse Size
(Amps)
2000
2000
3000
3000
6000
6000
60
200
200
200
600
600
1200
1200
When Used With
Molded Case Circuit Breakers
Withstand Rating
(RMS Symmetrical
@ 480 Vac Max.)
10,000
22,000
22,000
22,000
42,000
42,000
50,000
50,000
65,000
65,000
100,000
100,000
100,000
100,000
Maximum
Frame Size
(Amps)
2500
2500
2500
2500
4000
4000
50
150
150
225
600
600
2500
2500
Automatic Transfer Bypass-Isolation Switches (Per UL 1008)
Switch
Rating
(Amperes)
Mounting Height
(in.)
Middle
Top or
Bottom
150
260
400
600
800
45
72
72 a Rear access required. Back-to-back design.
36
72
72
When Used With Current Limiting Fuses
Class J, RK1, and L Types
Withstand Rating
(RMS Symmetrical
@ 480 Vac Max.)
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
Maximum
Fuse Size
(Amps)
200
600
600
1200
1200
2000
2000
3000
3000
When Used With
Molded Case Circuit Breakers
Withstand Rating
(RMS Symmetrical
@ 480 Vac Max.)
22,000
22,000
35,000
50,000
50,000
65,000
65,000
100,000
100,000
Maximum
Frame Size
(Amps)
225
600
600
2500
2500
2500
2500
2500
2500
27 © 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Automatic Transfer Switches
Class 2741/2742
1000
1200
1600
2000
3000
4000
30
70
100
150
260
400
600
800
NOTE: Please contact your local TAG to order automatic transfer switches.
Because of the complexity of automatic transfer switches, use careful consideration in the application, layout, and pricing of this product. The following information is required by the TAG at your local assembly plant to process your request for pricing and layout of automatic transfer switches:
1.
Complete specifications for the automatic transfer switch
2.
Front elevation and one-line of the switchboard
3.
A copy of your takeoff and pricing (quote number, item), less the requested product pricing
4.
If applicable, the manufacturer name and location, all necessary ratings, and catalog number(s) of the existing with which the automatic transfer switch is electrically connected.
Automatic Transfer Switches (Per UL 1008)
Switch
Rating
(Amperes)
Mounting Height
(in.)
Middle
Top or
Bottom
36
72
72
72
72
48
48
66
66
72
72
27
63
63
72
72
39
39
57
57
72
72
When Used With Current Limiting Fuses
Class J, RK1, and L Types
Withstand Rating
(RMS Symmetrical
@ 480 Vac Max.)
100,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
Maximum
Fuse Size
(Amps)
2000
2000
3000
3000
6000
6000
60
200
200
200
600
600
1200
1200
When Used With
Molded Case Circuit Breakers
Withstand Rating
(RMS Symmetrical
@ 480 Vac Max.)
10,000
22,000
22,000
22,000
42,000
42,000
50,000
50,000
65,000
65,000
100,000
100,000
100,000
100,000
Maximum
Frame Size
(Amps)
2500
2500
2500
2500
4000
4000
50
150
150
225
600
600
2500
2500
Automatic Transfer Bypass-Isolation Switches (Per UL 1008)
Switch
Rating
(Amperes)
Mounting Height
(in.)
Middle
Top or
Bottom
150
260
400
600
800
1000
1200
1600
2000
45
72
72 a Rear access required. Back-to-back design.
36
72
72
When Used With Current Limiting Fuses
Class J, RK1, and L Types
Withstand Rating
(RMS Symmetrical
@ 480 Vac Max.)
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
200,000
Maximum
Fuse Size
(Amps)
200
600
600
1200
1200
2000
2000
3000
3000
When Used With
Molded Case Circuit Breakers
Withstand Rating
(RMS Symmetrical
@ 480 Vac Max.)
22,000
22,000
35,000
50,000
50,000
65,000
65,000
100,000
100,000
Maximum
Frame Size
(Amps)
225
600
600
2500
2500
2500
2500
2500
2500
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
28
Square D™ Brand
QED-2 Switchboards
Automatic Throwover Systems
Class 2741/2742
The following features are standard for a Square D™ brand automatic throwover system.
The standard system features a Modicon microprocessor, plug-in technology for ease of retrofit/installation and programmable capability.
Main-
Generator
Feature
Standard Functions
Automatic transfer to alternate source, automatic retransfer to normal source
Automatic transfer to alternate source, manual return normal source
Bypass of retransfer delay if emergency fails
Electrically interlocked
Manual circuit breaker close buttons inhibited
Transition delay (2 seconds), open and closed transition
Source loss delay (3 seconds), before transfer
Source stabilization timer (10 seconds) before retransfer,
Undervoltage sensing on both sources, standard 100% nominal, 10% differential, adjustable
Phase sequence sensing on both sources, 2 cycles
Phase imbalance, 2%, adjustable
Phase loss, 68% phase loss
Auto / manual keyed switch w/ white light for auto and blue light for manual
Control power transfer
Full automatic mode with drawout breakers in the test position
Open (green) / close (red) lighted push buttons
Test switch—simulates loss of source
Circuit breaker electrical trip lockout w/ amber light indication
Uninterruptible power supply for 120 Vac control power
UPS bypass relay
Sources available (white) lights
Operator interface panel
Wire labels
Fused control circuits with individual blown fuse indication
Over-voltage sensing on generator (59),Standard 125% of nominal, 15% differential, adjustable
Frequency sensing on generator (81), standard 3 Hz differential, 0.1–3 Hz, adjustable
Engine start contacts, 5 A @ 120 Vac
Open transition
Remote alarm contact wired (system inoperative), 5 A @ 120 Vac
Generator exercising unloaded, 30 minutes, once per week
Time delay for engine cool down, 15 minutes unloaded standard
Optional Functions
Closed transition on retransfer
Sync check (25), 2 seconds maximum paralleling when sources synchronized, voltage 10%–30 % adjustable, phase relationship is 6° to 20°, and frequency is 0.15 Hz to 0.5 Hz
Generator exercise with load switch
Preferred source selector (Left-Off-Right), Left is standard
Automatic retransfer to normal switch
Touchscreen HMI
Main-Tie-Main Main-Main
✔
—
✔
✔
✔
✔
—
✔
✔
✔
—
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
—
—
—
✔
✔
✔
—
✔
—
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
—
—
—
✔
✔
✔
—
✔
—
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
—
✔
✔
NOTES: An automatic throwover system is not approved for use as a transfer switch per UL1008.
Both sources are paralleled during a closed transition. Short circuit contribution is additive from both sources.
29 © 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Square D™ Brand
QED-2 Switchboards
Automatic Throwover Systems
Class 2741/2742
NOTES: Systems and options other than those listed below require special pricing from the local assembly plant.
Pricing does not include the protective devices (Masterpact circuit breakers) for the utility sources or the generator source.
Pricing for automatic throwover systems include all of the standard features noted on page 29.
Features
Main-Tie-Main
List Price
Main-Main
List Price
Main-Generator
List Price
Standard Functions
$ 63929.
$ 61342.
$ 61342.
Optional Functions
Automatic return from alternate source
Remote alarm contact (system inoperative), 5 A @ 120 Vac
Closed transition on retransfer
Sync check (25), 2 seconds maximum paralleling when sources synchronized, voltage 10%–30 % adjustable, phase relationship is 6° to 20° and frequency is 0.15 Hz to 0.5 Hz
Time delay for engine cool down, 15 minutes unloaded standard
Engine generator exercising loaded or unloaded, 30 minutes once per week standard
Preferred source selector (Left-Off-Right), Left is Standard
Pilot lights test switch
Manual retransfer to normal switch
—
233.
6063.
1293.
530.
1166.
—
—
488.
233.
1293.
530.
—
—
233.
6063.
488.
488.
—
530.
—
Each main, tie or generator circuit breaker must be priced from the SW-2 pricing procedure or Q2C with the accessories listed below. These circuit breakers accessories are not included in the price of the automatic throwover system.
Circuit breaker accessories required for automatic throwover system:
1.
120 Vac electrical operation (includes shunt close, shunt trip and electrical operator)
2.
One set of auxiliary switches (one normally open and one normally closed)
3.
Alarm switch (one normally open contact)
4.
Cell position switch (one normally open required for drawout circuit breakers)
Automatic throwover systems are complex and may require adjustments during start-up. Voltage lower than anticipated, reversed phase sequence and unbalanced phase loading are but three examples. A one-day start-up charge is required for each system.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
30
Square D™ Brand
QED-2 Switchboards
Four-High Vertical Section (Canada only)
The price adder for this selection is $15000.
NOTE: Depth can be up to 60 in.
91.50
(2324)
1.50
(38)
36.00
(914)
6
19.5
19.5
19.5
19.5
6
Structure and Bussing
Class 2741/2742
Section Charge
Standard section price includes frames, side plates, rear plates, top plates, front covers, through bus, ground bus, base channels, engineering, and domestic crating and shipping.
Supply bus is per UL 891 Temperature Tests or will be sized to a cross-sectional area rating as shown in the footnotes.
Aluminum Supply Bus
UL891
Amperage
750 A/ sq. in.
Cross-
Sectional
Wire
600 A
800 A
1000 A
1200 A
1600 A
2000 A
2500 A
3200 A
600 A
750 A
—
—
1500 A
—
3000 A
—
1 sq. in.
1 sq. in.
1 sq. in.
1 sq. in.
2 sq. in.
2 sq. in.
4 sq. in.
4 sq. in.
3W
4W
3W
4W
3W
4W
3W
4W
3W
4W
3W
4W
3W
4W
3W
4W
Standard
Section
TIE Adder
$ 6869.
7325.
7420.
7886.
7886.
8544.
8448.
9158.
9423.
10452.
10452.
11554.
13568.
17225.
17766.
19557.
$ 9190.
9190.
9190.
9190.
9190.
9190.
9190.
9190.
12964.
12964.
12964.
12964.
12964.
12964.
22716.
22716.
200%
Neutral
Adder
Tin-Plated
Adder
—
$ 3074.
—
3540.
—
3837.
—
4282.
—
4834.
—
5936.
—
7653.
—
—
Tin-Plated is Standard
Taped Bus
Adder
$ 7049.
7844.
8448.
Copper Supply Bus Plated With Silver
UL891
Amperage
1000 A/ sq. in.
Cross-
Sectional
Wire
600 A
800 A
1000 A
1200 A
1600 A
2000 A
2500 A
3000 A
4000 A
5000 A
6000 A
600 A
800 A
1000 A
—
—
2000 A
—
—
4000 A
—
6000 A
1 sq. in.
1 sq. in.
1 sq. in.
1 sq. in.
1 sq. in.
2 sq. in.
2 sq. in.
2 sq. in.
4 sq. in.
4 sq. in.
6 sq. in.
3W
4W
3W
4W
3W
4W
3W
4W
3W
4W
3W
4W
3W
4W
3W
4W
3W
4W
3W
4W
3W
4W a 1 sq. in. x 750 A/sq. in. = 750 A for aluminum.
b 1 sq. in. x 1000 A/sq. in. = 1000 A for copper.
c QED-2 section only.
d Available only for incoming section.
e Requires increased depth to 48 in. minimum.
List Price
Per Section
TIE Adder
12720.
14130.
14130.
15900.
16578.
18550.
18932.
22546.
$ 9275.
9890.
10017.
10642.
10642.
11512.
11512.
12360.
23935.
27369.
32319.
36962.
45018.
48050.
12964.
12964.
12964.
12964.
12964.
12964.
18656.
18656.
$ 9190.
9190.
9190.
9190.
9190.
9190.
9190.
9190.
22716.
22716.
22716.
22716.
22716.
22716.
200%
Neutral
Adder
—
$ 3074.
—
3540.
—
3837.
—
4282.
—
4834.
—
5936.
—
7653.
Tin-Plated
Adder
Taped Bus
Adder
$ 4664.
$ 7049.
7844.
— 8448.
—
—
—
9423.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
31
Square D™ Brand
QED-2 Switchboards
91.50
(2324)
Firepump
Device
31.50
(800)
10.50
(267)
48.00
(1219)
Structures and Device Modifications
Class 2741/2742
Weather Resistant Switchboards—NEMA Type 3R Non-Walk-in
NEMA Type I—Depth
24 in. (QED-2, 2500 A maximum, no SE)
36 in. (QED-2, except 4000 A)
48 in. 5000 A QED-2)
60 in. (All QED-2 with Unit Substation)
Price Adder Per Section
(To Standard Section Charge)
$ 9307.
9307.
10642.
12328.
a For NEMA Type 3R walk-in enclosures, contact the Nashville Power Zone Center group (615-844-8300) for pricing and dimensions.
Structure And Device Modifications
Item
Auxiliary section: Any width (No horizontal bus available)
Barriers between sections: Steel/ Insulating
Bottom closure plates (not for combustible floor)
Corner section = 1.5 x section charge. Not available on 3R Enclosures
Optional copper ground bars
< = 2000 A Aluminum
< = 2000 A Copper
2001–3000 A Copper
3001–4000 A Copper
Doors on rear
Drip hood (NEMA Type 1 with drip hood). Not available on 3R Enclosures
DXF electronic format drawings on 3.5 in. diskettes for custom QED-2, QED-3, QED-4
Fire pump lugs: #10–2/0 or #6–350 kcmil per phase and neutral. Price auxiliary section separately.
Gasketed switchboard with filters (Use NEMA Type 3R construction; does not satisfy NEMA Type 12 requirements)
Ground detector lamps
Ground lug, per device
Hinged gutter covers on 63 in. high I-Line interior sections (single row / double row)
Increased depth (Standard = 24 in., 36 in., 48 in., 54 in., and 60 in.)
Insulated horizontal phase bus (taped)
1600 A max.
2500 A max.
3000 A max.
5000 A max.
Lighting panel—price from factory assembled Digest page and use box height plus 6 in. for mounting height; add for mounting
Mimic nameplate: Anodized aluminum or Plastic
Mimic bus—Tape/ (Plastic or Paint)
Nameplate—engraved adhesive or screw-on plastic; shipped uninstalled
Nameplate—engraved screw-on plastic; factory installed
Paint color—ANSI 49 is standard. Add for non-standard ANSI 61/Other
Pilot light or push button, Class 9001
Pullbox—open bottom (12 in. or 24 in. high) / with bottom barrier (12 in. or 24 in. high)
Reduced height section (75 in. high standard without base channel. For other heights, contact the A-plant.)
Rodent barrier
Corrosion-resistant base channels for NEMA Type 1 (Standard on NEMA Type 3R)
SIS control wire
Strip heaters—provisions for wiring to external source / wired (with overcurrent device and thermostat)
Surge arrestor (SDSA3650). Available only on grounded systems. This is NOT an SPD.
Terminal blocks, extra (per device) b For fire pump lugs in Canada, please contact your local TAG.
$ 5300.
—
List Price
Per Section
2109.
678.
7049.
7844.
8160.
9423.
—
—
5067. / 9922.
—
—
2767. / 4664.
—
1569. / 2290.
3858.
678.
2936.
710.
943. / 1855.
—
806.
Each
—
—
—
—
Standard
191.
382.
—
1155.
—
—
721.
1897.
—
3328.
375. / 1000.
1272.
—
—
—
—
—
—
$ 1060./SWBD
2120.
—
—
74.
—
—
—
—
—
1855.
1060.
—
159.
318.
—
445.
—
—
—
—
—
—
—
201.
Firepump Circuit Breakers (Canada Only)
Breaker Amperage 600 V, 50 kA Max.
60
100
125
150
175
200
225
250
800
1000
HLL36060
HLL36100
HLL36125
HLL36150
JLL36175
JLL36200
JLL36225
JLL36250
PKF36080
PKF36100
600 V, 65–100 kA
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
480 V, 100 kA Max 480 V, 125–200 kA 240 V, 125 kA Max 240 V, 130–200 kA
HLL36060
HLL36100
HLL36125
HLL36150
JLL36175
JLL36200
JLL36225
JLL36250
PLF36080
PLF36100
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HLL36060
HLL36100
HLL36125
HLL36150
JLL36175
JLL36200
JLL36225
JLL36250
PLF36080
PLF36100
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1.50
(38)
12.00
(305)
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1
Discount
Schedule
32
Square D™ Brand
QED-2 Switchboards
Circuit Breaker Definitions
Class 2741/2742
Thermal-Magnetic
A circuit breaker type which combines thermal and magnetic trip action to provide overload and short circuit protection.
A bimetallic element indirectly heated by the current flowing through the circuit breaker provides overload protection commonly referred to as “thermal” protection. On a continued overload, the bimetal will deflect, causing the circuit breaker’s tripping mechanism to open the circuit breaker contacts. The length of time the circuit breaker will maintain an overload can be determined by review of the circuit breaker’s characteristic tripping curve. Magnetic action (also referred to as instantaneous trip) is achieved through the use of an electromagnet. High level fault currents provide the electromotive force necessary to activate the circuit breaker tripping mechanism to open the circuit breaker contacts. the magnetic trip point may be fixed or adjustable. Thermal-magnetic circuit breakers are best suited for the majority of general purpose applications because they are temperature sensitive.
Current Limiting
A current limiting circuit breaker protective device is a device which, when interrupting currents in its current limiting range, will reduce the current flow in the faulted circuit to a magnitude substantially less than that obtainable in the same circuit if the device were replaced with a solid conductor having comparable impedance. A limiting circuit breaker does not use fuses.
Integrally Fused
The integrally fused circuit breaker combines a thermal-magnetic circuit breaker and high interrupting rated fuses in a mechanically integral housing. Overloads and low level fault currents are cleared by the circuit breaker’s thermalmagnetic action. Very high fault currents are cleared by the series fuses, and the mechanical linkage will open the circuit breaker contacts to prevent a possible single phase condition and provide trip indication.
Magnetic-only
Magnetic-only circuit breakers provide short circuit protection, but do not contain any thermal elements; therefore, they do not provide overload protection. The magnetic trip elements are front adjustable for trip range based on the circuit breaker’s continuous current rating. Magnetic-only circuit breakers are not for use in switchboards or panelboards, unless factory assembled and used with motor starting equipment (for example, I-Line combination motor starters).
Electronic Trip
The solid-state circuit breaker uses current transformers, solid-state circuitry, and a flux transfer shunt trip in place of the conventional thermal-magnetic trip mechanism to provide both overload and short circuit protection. Some solidstate trip units use two current transformers in each phase to reduce the current to the proper ratio for input into the solid-state circuitry. Under prolonged overloads or short circuit conditions, the solid-state circuitry initiates an output to a low power flux transfer with interchangeable rating plug. The static sensor has several separate adjustments that can be varied to make the circuit breaker’s trip characteristics fit the requirements of the power system. These seven adjustments are long-delay pickup point, long-delay tripping time, short-delay pickup point, short-delay tripping time, instantaneous trip pickup, ground current pickup, and ground current time delay.
Electronic trip unit types for Schneider Electric include:
• Basic—Fixed long-time; adjustable instantaneous
• Standard—Adjustable long-time, short-time, and instantaneous
• Advanced—Standard functions plus optional ground fault—(Ammeter, Energy, Power, or Harmonic trip units)
Mission Critical Circuit Breakers
Designed for selectively coordinated systems, mission critical circuit breakers maximize continuity of the electrical service by allowing the branch circuit breaker to clear the fault. Mission critical circuit breakers are engineered with technology that optimizes current, time, and energy selectivity so the fault is cleared by the circuit breaker immediately upstream of the occurrence. This technology allows the remaining areas of the electrical system to continue to operate without disruption.
33 © 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Class 2700
Square D™ brand OEM interiors are available to Original Equipment Manufacturers for mounting in enclosures. Two versions are offered for device requirements of I-Line circuit breakers or QMB fusible switches. Square D™ brand
OEM interiors are not intended for field installation in existing facilities.
Single Row I-Line Interiors
Catalog No.
CF16M27C
CF20M27C
CF16M36C
CF20M36C
CF16R63C
CF20R63C
CF25R63C
CF30R63C
Amperage (A)
1600
2000
1600
2000
1600
2000
2500
3000
Panel Height (in.)
36
63
63
63
63
27
27
36
Available Circuit Breaker Mounting Space (in.)
Left
27
63
63
63
63
18
18
27
Right
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
List Price
$ 5192.
5949.
6042.
7017.
9758.
12158.
13230.
14175.
Double Row I-Line Interiors
Catalog No.
CF20MK27C
CF20MK36C
CF16KF63C
CF16NK63C
CF20KF63C
CF20NK63C
CF30RJ63C
Amperage (A)
2000
2000
1600
1600
2000
2000
3000
QMB Interiors
Catalog No.
CF8FU15C
CF16FU30C
CF20FU72C
CF30FU72C
Amperage (A)
800
1600
2000
3000
Panel Height (in.)
63
63
63
63
27
36
63
Available Circuit Breaker Mounting Space (in.)
Left
54
54
54
63
18
27
54
Right
63
63
63
45
27
36
63
Panel Height (in.)
15
30
72
72
Maximum Switch by Section Width
32 in.
400 A
1200 A
1200 A
1200 A
42 in.
800 A
1200 A
1200 A
1200 A
List Price
$ 6074.
7224.
8786.
8969.
10748.
11001.
19875.
List Price
$ 4040.
6042.
6498.
7478.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
PE1A
Discount
Schedule
34
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
General Instructions
Class 2705
This pricing guide contains pricing information for factory-assembled Multi-Distribution
Switchboards (MDS) manufactured by Schneider Electric. MDS switchboards consists of one or more switchboard sections with standard depths of 14 in. All components listed in this pricing procedure can be placed in factory-assembled switchboards.
Features
• 1200 A maximum bus design
• Aluminum bus (optional: copper bus)
• Main devices are MCCB (250–1200 A)
• Up to 117 in. I-Line double row branch mounting space available
• Continuous copper ground bus
• Painted steel construction; all covers painted ASA49 gray
• NEMA sprinkler-protected enclosure standard
• Floor mounted
• Single section (main, utility service, distribution) with add-on distribution sections option
• Compact 14 in. depth
• Certified and tested to CSA C22.2, No. 31
MDS Switchboards
Enclosure Type
NEMA Type1
Drip hood (optional)
Sprinkler Protected as per CEC26-008 (optional)
Dimensions
Main
Distribution
Volts
Amperes
Bus Type
Utility Compartment
Interrupting Capacity
Entry
Main Device
Branch Devices Unit Space
Metering Devices
Other Options
30 in. W x 90 in. H x 14 in. Dp
38 in. W x 90 in. H x 14 in. Dp
36 in. W x 90 in. H x 14 in. Dp
42 in. W x 90 in. H x 14 in. Dp
600 V Max
400–1200 A
Aluminum (tin plated)
Copper (silver finished; optional)
CT/PT meets any Canadian Utility Requirements
50 kA and lower
65 kA at 600 V (optional with PowerPact P-frame)
200 kA at 480 V (optional with new PowerPact L-frame)
Cable (top or bottom) or
Bussing through side
MCCB 400–1200 A
80% Rated
100% Rated (optional)
42 circuits mounted on NF panel in main section
54 circuits mounted on NQ panel in main section
36 in. high in double row or 18 in. high in single row I-Line in main section
54 in. high single row or 117 in. high in a double row in distribution section
Schneider Electric power meter or I-ON meter with remote display
I-ON 6200 revenue metering (optional)
SPD units
Rodent barrier
Fast delivery (less than 5 days)
Add-on distribution sections to both sides of main section
To determine the correct number of switchboard sections, use the inches of mounting height of the devices. Total all the metering and main inches and determine the number of sections. Then total all the branch distribution inches and determine the quantity of sections.
For information on layout, refer to Catalog #S2705CT1301BP R0, Multi-Distribution
Switchboards.
• Inches (in.) x 25.4 = millimeters (mm)
• Square inches (sq. in.; in.
2 ) x 45.16 = square millimeters (mm 2 )
• Cubic inches (cu. in.; in.
3 ) x 16.387 = cubic centimeters (cc; cm 3 )
• Pound inches (lb. in.) x 0.113 = Newton meters (N • m)
35
MDS Low Voltage
Switchboards
CSA Service Entrance
Class 2705
Switchboards used as service entrance equipment include CSA label, main bonding jumper, neutral disconnect link, ground bus, grounding lug, and barriers.
Main Type
Individually mounted main
Single Main
$1410.
Canada Utility
Name
BC Hydro
Hydro One
Brampton
Hydro Quebec
Mississauga
Saskatoon
Toronto Hydro
Other
C/T Provision
MV-7 (Standard Bar Type), or
MV-7 (1P 3W) (Dual Bar Type), or
R6MC (Window Type), or
R6L (Window Type), or
JAK-0 (Window Type), or
JAD-0 (Window Type), or
Unknown C/T( $1400.
)
P/T
Provision
Available
System
3W
800 A and
Lower
$7,377.
1000 or
1200 A
$12,741.
4W 9,836.
16,988.
NOTE: Some utilities in Canada require ground studs. Pricing is $4240.
Adder for wooden cable support for BC Hydro: $875.
Incoming Auxiliary Section Type
Main is Remote
Single Main Incoming Auxiliary
Bussed Auxiliary
Un-Bussed
Bussed
Drip Loop
c Cable entry plate $1500.
In conjunction with a Bussed
Auxiliary for
BC Hydro
N/A
Height (in.) Width (in.) Depth (in.)
91.5
91.5
91.5
91.5
91.5
24
16
24
24
12
14
14
600 A 800 A 1000 A 1200 A
14, 18, or 24
Refer to tables on page 38 and add incoming lug pricing as below
Same as
Incoming
Auxiliary
Section
24
Refer to tables on page 38 and add incoming lug pricing as below
$5300.
Pricing includes two sections (one Incoming bussed auxiliary and one unbussed section)
$7325.
$7886.
$8544.
$9158.
Incoming Lugs
System
3W OR 4W
400, 600, or 800 A
$2120.
1000 or 1200 A
$3180.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
SS8E
Discount
Schedule
36
MDS Low Voltage
Switchboards
31.50
(800)
91.50
(2324)
Firepump
Device
10.50
(267)
48.00
(1219)
Fire
Pump
100 A
Circuit
Breaker
Customer
Incoming
Connection
Main
Fire Pump
Class 2705
1.50
(38)
12.00
(305) Section 1
Fire Pump Circuit Breaker Pricing
Circuit Breaker Amperage (A)
175
200
225
250
60
100
125
150
List Price
$ 4240.
4378.
7102.
7102.
7759.
7759.
7759.
9116.
Section 2
Catalog Number
HLL36060
HLL36100
HLL36125
HLL36150
JLL36175
JLL36200
JLL36225
JLL36250
37
SS8E
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
MDS Low Voltage
Switchboards
Distribution Section Charges and Structure Modifications
Class 2705
The standard section price includes frames, side plates, rear plates, top plates, front covers, through bus, base channels, engineering, and domestic crating.
Structure Modifications (Incoming/Main/Distribution Section)
Item
Type 1 enclosure
Type 2 enclosure
Sprinkler protection as per CEC 26-008
Pullbox
With open bottom (24 in. high)
With bottom barrier (12 or 24 in. high
Rodent barrier (per section)
Door over Distribution section, 63 in. high
List Price
—
$ 237.
1155.
1569.
2290.
678.
1897.
Aluminum Bus Structure (Incoming/Distribution/Fire Pump Section)
System Ampacity (A) Ground Bus
600
800
1000
1200
Wire
3W
4W
3W
4W
3W
4W
3W
4W
$ 191.
Silver-plated Copper Bus Structure (Incoming/Distribution/Fire Pump Section)
System Ampacity (A) Ground Bus
600
800
1000
1200
Wire
3W
4W
3W
4W
3W
4W
3W
4W
$ 191.
List Price
$ 6869.
7325.
7420.
7886.
7886.
8544.
8448.
9158.
List Price
$ 9275.
9890.
10017.
10642.
10642.
11512.
11512.
12360.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
SS8E
Discount
Schedule
38
MDS Low Voltage
Switchboards
Main Section
Class 2705
Single section without horizontal bus. (Distribution sections cannot be added in the future.)
List Price
Vertical Bus Material
Aluminum
Copper
Up to 800 A
$ 3445.
5300.
1000 and 1200 A
$ 3445.
5300.
NOTE: Feeder compartment pricing on main section is not included.
Multiple section with horizontal bus and optional, future distribution section add on.
Bus Material
600 A
List Price
800 A
Aluminum
Copper
$ 7325.
9890.
$ 7886.
10642.
1200 A
$ 9158.
12360.
39
SS8E
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
MDS Low Voltage
Switchboards
Type
Power Meter
I-ON Meter
Includes remote display and is
Schneider Electric-branded
I-ON 6200
I-ON 7330
I-ON 7350
Catalog Number
PM-820
PM-850
PM-870
P6200R2A0B0A0A3N
Standard measurement package
P6200R2A0B0A0A3P
Enhanced, 1-measurement package
P6200R2A0B0A0A3R
Enhanced, 2-measurement package
P6200R2A0B0A0B3N
Digital output; Standard measurement package
P6200R2A0B0A0B3P
Digital output; Enhanced, 1-measurement package
P6200R2A0B0A0B3R
Digital output; Enhanced, 2-measurement package
P7330R0B0B0A0A0A
Serial communications option
P7330R0B0B0E0A0A
Serial and Ethernet communications options
P7350R0B0B0A0A0A
Serial communications option
P7350R0B0B0E0A0A
Serial and Ethernet communications options
Accessory
Power Meter 820, 850, 870
Catalog Number
PM8M22
2 digital inputs, 2 digital outputs
PM8M26
6 digital inputs, 2 digital outputs
PM8M2222
2 digital inputs, 2 digital outputs,
2 analog inputs, 2 analog outputs
PM8ECC
Ethernet communications card
List Price
$ 2809.
3275.
3646.
11501.
Customer Metering
Class 2705
List Price
$ 18465.
24804.
29250.
45630.
50090.
55500.
57000.
58000.
59000.
20900.
24730.
27360.
29190.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
SS8E
Discount
Schedule
40
MDS Low Voltage
Switchboards
Main Circuit Breakers
Class 2705
Circuit Breaker
Type
Ampere Rating Frame Type
M Frame Basic
Electronic
300
350
400
450
500
600
700
800
MG
MJ
P-Frame Basic
Electronic
600
800
1000
1200
PG
PK
PJ
PL
Interrupting Rating (kA) Max UL/CSA
240 Vac 480 Vac 600 Vac
65
100
65
65
100
125
35
65
35
50
65
100
18
25
18
50
25
—
Available Trip
Values
300–600
700–800
300–600
700–800
600–800
1000–1200
600–800
1000–1200
600–800
1000–1200
600–800
1000–1200
List Price
2-Pole
$ 11671.
15179.
3-Pole
$ 13589.
18338.
14043.
18592.
15673.
16982.
18291.
19600.
20909.
22218.
23527.
24836.
16663.
21423.
18790.
19891.
20992.
22093.
23194.
24295.
25396.
26497.
P-Frame
Advance
Electronic Trip
See the Electronic Trip—Standard and Advanced table on page 17.
L- Frame 80%
Advance
Electronic
L- Frame 100%
Advance
Electronic
200–600
70–250
125–400
200–600
70–250
125–400
200–600
70–250
125–400
200–600
70–250
125–400
200–600
70–250
125–400
70–250
125–400
70–250
125–400
70–250
125–400
70–250
125–400
70–250
125–400
LD
LG
LJ
LL
LR
LD
LG
LJ
LL
LR
25
65
100
125
200
25
65
100
125
200
18
35
65
100
200
18
35
65
100
200
14
18
25
50
100
14
18
25
50
100
200
225
250
300
350
400
125
150
175
200
225
250
300
350
400
200
225
250
300
350
400
450
500
600
125
150
175
200
225
250
300
350
400
24 Vdc power supply for trip unit power. Required for PowerPact P with P or H trip units and PowerPact L with an ammeter or energy trip unit; recommended for PowerPact P with A trip units.: $1950.
Control power transformer (only one required per vertical section).: $890.
9102.
8579.
8579.
10191.
9866.
9866.
11719.
4302.
4302.
6220.
4516.
4516.
6534.
7369.
7369.
5034.
5034.
5284.
5284.
8622.
8622.
10037.
10037.
11543.
11543.
11378.
10724.
10724.
12738.
12332.
12332.
14649.
5378.
5378.
7775.
5645.
5645.
8167.
9212.
9212.
6292.
6292.
6604.
6604.
10778.
10778.
12547.
12547.
14429.
14429.
41
SS8E
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
MDS Low Voltage
Switchboards
Group Mounted NQ ™ Circuit Breakers—Branch
Class 2705
NQ Interiors
List Price
NQ Interior
54 Circuits
400 A
600 A
1PH/3W
$ 1600.
2082.
3PH/4W
$ 2112.
2326.
Adder for Copper Busbar
$ 388.
388.
NQ Circuit Breakers
Device Mounting Breaker Frame ID
QOB
Bolt On
Plug On
QOB-VH
QHB
QOB
QOB-VH
QHB
QOB
QOB-VH
QHB
QO
QO-VH
QH
QO
QO-VH
QH
QO
QO-VH
QH
Number of Poles
1
1
1
2
3
3
1
1
1
2
2
2
3
2
2
3
3
3
NQ Accessories
Handle Attachments for QO and QOB Circuit Breakers
Padlock attachment, fixed-off
Number of Poles
1
2 or 3
Trip Amps (A)
70
15–30
15–30
15–60
70
80–100
110–125
15–60
15–60
70
80–100
15–60
70
80–100
15–30
15–60
70
80–100
110–125
15–60
70
80–100
110–125
15–30
15–60
70
15–30
40–60
70
15–30
15–60
70
80–100
110–125
15–30
15–60
70
80–100
15–60
70
80–100
15–30
List Price
$ 26.
26.
Base List Price
$ 68.
100.
92.
208.
262.
482.
212.
292.
378.
1022.
348.
556.
606.
596.
68.
100.
92.
144.
134.
352.
396.
458.
462.
556.
606.
596.
292.
378.
1022.
348.
352.
396.
458.
462.
109.
175.
144.
134.
208.
262.
482.
212.
Shunt Trip Adder
120 Vac or 208 Vac or 240 Vac
$ 200.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
SS8E
Discount
Schedule
42
MDS Low Voltage
Switchboards
43
NF Interiors
Group Mounted NF Circuit Breakers—Branch
Class 2705
List Price
NF Interior
42 Circuits
400 A
600A
800 A
NF Circuit Breakers
1PH/3W
$ 1426.
2366.
3550.
3PH/4W
$ 1924.
2622.
3900.
Adder for Copper Busbar
$ 624.
624.
624.
Maximum Volts Breaker Frame ID Number of Poles
Shunt Trip Adder
120Vac
480Y/277
600Y/347
EDB
EGB
EJB
EDB
EGB
EJB
EDB
EGB
EJB
EDB
EGB
EJB
EDB
EGB
EJB
EDB
EGB
EJB
1
1
1
2
2
2
3
3
3
1
1
1
2
2
2
3
3
3
Trip Amps (A)
110
125
15–60
70–100
110
125
15–60
70
110
125
15–60
70–100
110
125
15–60
70–100
70–100
110–125
15–60
70–100
110
125
15–60
70–100
15–60
70
15–60
70
15–60
70
15–60
15–60
70–100
15–60
70–100
15–60
70–100
15–60
70–100
15–60
70
15– 60
70
15–60
70–100
15–60
70 –100
Base List Price
$ 192.
342.
324.
578.
518.
924.
442.
872.
2,210.
746.
1,474.
4,114.
1,196.
2,120.
5,300.
748.
1,046.
2,724.
1,264.
1,710.
4,754.
2,024.
2,540.
6,300.
746.
1,474.
746.
1,474.
748.
1,046.
1,264.
1,710.
2,024.
2,540.
192.
342.
324.
578.
518.
924.
442.
872.
$ 958.
NF Accessories
Description
Padlock attachment, fixed-off/on
SS8E
Discount
Schedule
Number of Poles
1, 2, or 3
Catalog Number
EDPA
List Price
$ 26.
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
MDS Low Voltage
Switchboards
Group Mounted I-Line™ Circuit Breakers—Branch
Class 2705
Interior Pricing
Interior Height (in.) List Price
Aluminum
Copper
Busbar Material
18
$ 3840.
5875.
I-Line Branch Circuit Breaker Gutter Dimensions
Double Row Single Row
14.96
(380)
12.63
(321)
12.78
(317)
11.78
(299)
8.78
(223)
8.49
(216)
FH,
FA
FI, KI
J
H
LA, LH
4.50
(114)
4.50
(114)
4.50
(114)
4.50
(114)
6.00
(152)
LD, LG, LJ,
LL, LR
6.00
(152)
FH,
FA
FI
H
8.44
(214)
LC, LE, LI,
LX, LXI
7.50
(191)
7.48
(190)
5.15
(131)
5.00
(127)
8.23
(209)
P, M
9.00
(229)
18.96
(482)
16.63
(422)
16.48
(419)
15.78
(401)
12.78
(325)
12.49
(317)
FH,
FA
FI, KI
J
H
4.50
(114)
4.50
(114)
4.50
(114)
4.50
(114)
LA, LH
6.00
(152)
LD, LG, LJ,
LL, LR
6.00
(152)
12.44
(316)
LC, LE, LI,
LX, LXI
7.50
(191)
12.23
(311)
P, M
9.00
(229)
Section With Through Bus
• With P or L Frame
— 1 x 600 A and 2 x 150 A (H frame), or
— 2 x 400 A and 1 x 150 A (H frame), or
— 3 x 250 A
• With J Frame only
— 4 x 250 A
Section Without Through Bus
• With P or L Frame
— 2 x 600A and 1 x 225A, or
— 1 x 600A and 2 x 400A
• With J Frame only
— 4 x 250A
Wide Side, Section With Through Bus
• With P or L Frame
— 1 x 400 A and 2 x 150 A (H frame)
•
With J Frame only
— 3 x 250 A and 1 x 150 A (H frame)
Wide Side, Section Without Through Bus
•
With P or L Frame
— 1 x 600 A and 1 x 400 A and 1 x 150 A, or
— 1 x 600 A and 2 x 200 A
• With J Frame only
— 4 x 250 A
Narrow Side, Section With or Without Through Bus
• With H Frame
— 4 x 150 A
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
SS8E
Discount
Schedule
44
MDS Low Voltage
Switchboards
Group Mounted I-Line™ Circuit Breakers—Branch
Class 2705
Interior Pricing—Full Height Distribution Section
Bus Material
Single Row
Aluminum
Copper
Double Row
Aluminum
Copper
Mounting Space Height (in.)
54
117
List Price
$ 6500.
10000.
7605.
14040.
Group Mounted I-Line Circuit Breakers—Branch
•
The maximum amperage of any I-Line circuit breaker is 800 A.
• Thermal circuit breakers are available only as a 80% rated device in the following frame types:
— FA, FH, FJ, HD, HG, HJ, HL, QB, QD, QG, QJ, JD, JG, JJ, JL, JR, MG, MJ, PG, PJ, PK, PL
•
Electronic circuit breakers are available in the following frame types:
— HD, HG, HJ, HL, HR, JD, JG, JJ, JL, JR, LD, LG, LJ, LL, LR, PG, PJ, PK, PL
Use QED-2 pricing on pages 16–18.
For PowerPact with Micrologic Trip Mission Critical Circuit Breakers, see the table on page 18.
Accessories
Item
Padlock attachment
Key interlock (Kirk type)
M and P frame
Plus padlock only on P frame
Cylinder lock available on FA and FH circuit breakers
Alarm switch
F, H, J, and L frame
M and P frame
Shunt Trip
F, H, J, and L frame
M and P frame
Over current trip switch on P frame
Auxiliary contacts
1A + 1B on all except Q frame
2A + 2B on all except Q frame
3A + 3B on L, M, and P frame
List Price
$ 32.
1897.
1929.
636.
276.
488.
647.
1198.
466.
466.
647.
848.
45
SS8E
Discount
Schedule
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
MDS Low Voltage
Switchboards
Miscellaneous
Class 2705
List Price Amperage (A)
400
600
800
1000
1200
$ 2544.
3816.
Individually Mounted
System Voltage
(Vac)
120/240, 1P3W
208Y/120, 3P4W
208Y/120, 3P4W
480Y/277, 3P4W
600Y/347, 3P4W
100 kA
$ 20416.
21260.
21260.
22110.
23000.
120 kA
$ 21692.
22588.
22588.
23492.
24438.
List Price
160 kA
$ 25520.
26574.
26574.
27638.
28750.
240 kA
$ 36420.
38050.
38050.
39686.
41400.
320 kA
$ 41882.
43758.
43758.
45638.
47602.
480 kA
$ 49979.
56604.
56604.
63854.
63854.
I-Line Mounted; SPD Mounting Height = 13.5 in.
System Voltage
(Vac)
120/240, 1P3W
208Y/120, 3P4W
208Y/120, 3P4W
480Y/277, 3P4W
600Y/347, 3P4W
120 kA
100 kA SCCR
$ 20088.
20984.
20984.
21898.
—
100 kA SCCR
$ 21692.
22588.
22588.
23492.
24438.
List Price
160 kA
100 kA SCCR
$ 23634.
24688.
24688.
25752.
—
200 kA SCCR
$ 25520.
26574.
26574.
27638.
28750.
240 kA
100 kA SCCR
$ 34534.
36164.
36164.
37800.
—
200 kA SCCR
$ 36420.
38050.
38050.
39686.
41400.
Surge counter is offered by default on all.
Remote monitor: $2588.
Surge arrester: $806.
; Catalog number: SDSA3650 or SDSA1175
© 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
SS8E
Discount
Schedule
46
47 © 2013 Schneider Electric All Rights Reserved
Prices subject to change without notice.
09/2013
Schneider Electric USA, Inc.
1415 S. Roselle Road
Palatine, IL 60067 USA
1-888-778-2733 www.schneider-electric.us
Schneider Electric Canada, Inc.
5985 McLaughlin Road
Mississauga, ON L5R 1B8 Canada
Tel:1-800-565-6699 www.schneider-electric.ca
© 2013 Schneider Electric All Rights Reserved
All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies
2700PL9201R09/13 Replaces 2700PL9201R1/09 01/2009
09/2013