Crosby_ReliefValve_JOS_JBS_JLT_cat_D495 Crosby Styles JOS, JBS and JLT ® ® Flanged, Full Nozzle Pressure Relief Valves Table of Contents Crosby® Styles JOS, JBS and JLT Pressure Relief Valves for Gas, Vapor and Liquid Service Features and Benefits Full Compliance with ASME Code Requirements Crosby Styles JOS, JBS and JLT valves are manufactured in accordance with ASME Boiler and Pressure Vessel Code, Section VIII. National Board Certified Capacities Relieving capacities are certified by the National Board of Boiler and Pressure Vessel Inspectors. Certification includes air, steam and water. Positive Operating Characteristics Crosby Styles JOS, JBS and JLT pressure relief valves have been designed with single nozzle ring control which allows the user to adjust the valve to the process system. Excellent Seat Tightness Precision lapped flat metal-to-metal or soft seats provide reliable seat tightness for a broad variety of applications. Easy Interchangeability, Flexibility and Versatility Fully interchangeable from conventional to bellows to liquid trim constructions, from metal to soft seats, and from closed to open bonnets with minimum parts changes. Maximum Corrosion Resistance Nozzle, disc insert and most internal parts are 316 stainless steel. All 316 stainless steel, Monel *, Hastelloy ** and NACE optional constructions are available. Reduced Installation Costs Crosby Styles JLT-JOS and JLT-JBS provide high efficiency at 10% overpressure permitting selection of smaller valves and associated piping. Economical to Maintain Stable, chatter-free valve operation prolongs valve life and reduces frequency of seat maintenance. Reduced Down Time Crosby pressure relief valves are fully backed by a worldwide manufacturing and sales organization, including spare parts inventories and repair services. *Monel is a registered trademark of the International Nickel Company, Inc. **Hastelloy is a registered trademark of Haynes International, Inc. Features and Benefits Introduction/Description Style Variations Descriptions Style Designation Chart O-Ring Soft Seats Valve Materials of Construction Caps and Lifting Levers Specifications Capacity Tables (U.S.C.S.) 2 Page Pages Pages Page Page Pages Pages Pages Pages Table of Contents 2 3-5 6-7 8 9 10-11 12-13 14-43 44-50 Please refer to Warranty and Warnings on page 63. Equivalents and Conversion Factors Page 51 Capacity Tables (Metric) Pages 52-57 Crosby Critical Application Valves Page 58 JBS-BP/JLT-JBS-BP Balancing Piston Page 59 Flange Information Page 59 NACE MR0175 Sour Gas Service Pages 60-61 Seat Tightness Standard Page 62 Ordering Information/Warranty Page 63 Crosby Products, Services and Back Cover Crosby® Styles JOS, JBS and JLT Pressure Relief Valves cover process plant overpressure protection applications and complement our other extensive lines to satisfy your diversified requirements Style JOS and JBS Style JLT-JOS and JLT-JBS Style JOS-H (With Open Bonnet) INTRODUCTION Crosby Styles JOS/JBS/JLT and JOS-H pressure relief valves are backed by over 120 years of pioneering research and development. Designed to provide high quality standardized overpressure protection to the process and power industries, the JOS/JBS/JLT unified line of pressure relief valves provides overpressure protection for air, gas, steam, vapor and liquid applications. Standard sizes are 1" D 2" to 8" T2 10" with inlet flange ratings of ANSI Cl 150, 300, 600, 900, 1500 and 2500. Standard outlet flanges are ANSI Cl 150 or Cl 300 depending on valve size and rating. Optional materials of construction are available for special applications such as cryogenic service or conditions involving corrosive fluids. In addition, materials are available conforming to NACE MR0175. Codes and Standards JOS/JBS/JLT and JOS-H full nozzle top guided pressure relief valves are manufactured in accordance with requirements of ASME Code, Section VIII and capacities are certified by the National Board of Boiler and Pressure Vessel Inspectors. They also comply with the recommended standards of the U.S. Coast Guard (U.S.C.G.) and conform to API Standards 526 and 527. Sizing For information pertaining to sizing and selection, refer to the CROSBY-SIZE Computer Sizing Program and the Crosby Pressure Relief Valve Engineering Handbook. Seat Design Styles JOS/JBS/JLT pressure relief valves are available with flat metal-to-metal seats or soft seats for optimum tightness and minimal maintenance. Details on O-ring materials and pressure/temperature limitations are on page 9. All O-rings are standard commercial sizes. Caps/Lifting Lever Top Constructions Both Type J screwed cap and Type L bolted cap are offered with or without test rods. Also available are Type C regular lifting lever, Type D packed lifting lever and Type E packed lifting lever with test rod. See pages 12 and 13. Optional Steam Jackets For applications where the valve must remain hot to prevent service fluid from solidifying, optional steam jackets are available. Contact the factory. Sizes: Orifices: 1" D 2" to 8" T2 10"* D (0.110 sq.in.) to T2 (27.872 sq.in.)* D (71 sq.mm) to T2 (17981 sq.mm)* Inlet Ratings: ANSI Cl 150, 300, 600, 900, 1500 and 2500 Temperature Range: -450F to +1000F (-268C to +538C) Pressure Range: JOS and JLT-JOS: 15 to 6000 psig (1.03 to 413.79 barg)** JBS and JLT-JBS: 25 to 6000 psig (1.72 to 413.79 barg)** *Larger sizes are available on application. ** Consult Factory for lower set pressures. See Catalog No. 307 for details. Please refer to Warranty and Warnings on page 63. 3 Crosby® Styles JOS, JBS, and JLT Pressure Relief Valves handle process fluids in hostile environments; provide seat tightness and reliable performance you need Spindle construction on smaller valves thru K orifice All internal parts shown in color are stainless steel as standard. Ball joints above and below guide assure a tight seal and proper alignment, prevent valve seat damage due to seat rotation during set pressure adjustment. Balanced bellows protects Style JBS valve and environment against effects of corrosive and toxic fluids; assures top performance under conditions of superimposed and built-up variable back pressure in the discharge line. 4 Please refer to Warranty and Warnings on page 63. D-N Orifice Construction Standard Style JOS Standard Trim with metal-to-metal seat P-T Orifice Construction Optional Style JLT Liquid Trim with metal-to-metal seat (Standard) Rugged construction/high performance High coefficient of discharge Exceptionally rugged, standardized construction is provided in a design that can be easily converted from conventional to balanced bellows type.The disc holder is centered and aligned in a hard, corrosion-resistant, stainless steel guide for durability and high performance. The two-piece disc holder/disc insert construction provides thermal balancing assuring maximum seat tightness. Stainless steel internal parts allow standard Style JOS/JBS/JLT valves to be used "off-the-shelf" for most process overpressure protection applications. Crosby Style JLT pressure relief valves for liquid service offer a significant increase in capacity at 10% overpressure. This high capacity, in many cases, results in economic use of a smaller valve with an associated reduction in piping costs. Single nozzle ring control permits shop or field adjustment to ensure relieving at full capacity flow within allowable 10% overpressure at all possible ring positions. Commercial metal-to-metal seat tightness Corrosion resistant materials To accommodate severe conditions or corrosive fluid, Crosby Styles JOS/JBS/JLT pressure relief valves are available in a number of special material combinations such as Monel, Hastelloy and stainless steel. For pressure relief valves meeting the material requirements of NACE Standard MR0175 for sour gas service, see pages 60 and 61. Selection of corrosion resistant materials requires complete knowledge of the process fluid. The special materials detailed in this catalog cover the majority of requirements. Where specific applications require materials of construction not shown in this catalog, consult Crosby or your local Crosby sales representative. Stable operation Crosby's smooth, stable operation over a wide range of system conditions significantly reduces noise and vibration. This results in lower maintenance and repair costs. Styles JOS/JBS/JLT valves are engineered to provide the tightest possible shutoff in a metal-to-metal seat. The finely lapped and thermally balanced two-piece disc assembly is protected by ball joints above and below the guide and at the spring washers. These ball joints prevent rotational damage to the free floating disc insert during set pressure adjustments, and assure proper alignment, performance and easy-tomaintain seat tightness. Refer to pages 4 and 62. Exceptional soft seat tightness For exceptional tightness, Crosby offers an O-ring soft seat design capable of handling pressures to 1480 psig (102 barg). Standard O-ring materials include Viton*, Buna N, EPR, TFE, silicone rubber and Kalrez**. Temperature and pressure limits of each material are shown on page 9. Other soft seat materials may be available on application. Consult Crosby. Extreme temperature service For applications involving unusually high and low temperatures, Crosby offers five different combinations of valve materials which incorporate the recommendations of American Petroleum Institute Standard 526 or an upgrade thereof. Materials of construction are available for temperatures ranging from -450F to +1000F (-268C to +538C). See pages 10 and 11. For applications above +1000F (+538C) contact Crosby. * Reg. U.S.Pat.Office for Du Pont's fluoroelastomer. ** Reg. U.S.Pat.Office for Du Pont's perfluoroelastomer parts. Please refer to Warranty and Warnings on page 63. 5 Style Variations Style JOS Style JBS Crosby Conventional Style JOS Crosby Balanced Bellows Style JBS Crosby Style JOS is the basic conventional pressure relief valve most frequently used in process applications. This valve has a closed bonnet that contains the process fluid within the valve preventing any release to the atmosphere. Style JOS closed bonnet valves may be specified with a screwed or bolted cap, or with a regular or packed lifting lever. The bonnet vent is always plugged. For steam service, the JOS valve may also be supplied with an open bonnet and a regular lifting lever (Style JOS-H). Crosby Style JBS incorporates a balanced bellows to provide satisfactory valve performance when the developed back pressure becomes excessive. The balanced bellows design will assure that valve characteristics such as lift and relieving capacity, opening and closing pressure, and stability are not unduly influenced by static pressure in the discharge manifold. Conventional pressure relief valves are installed when the discharge is either into a short tailpipe that vents directly to the atmosphere or when the discharge is into a low pressure exhaust system designed to contain the fluid. Balanced pressure relief valves must be installed when the built up back pressure in the exhaust system is allowed to exceed 10% of the valve set pressure. Style JBS valves must also be installed when the back pressure is superimposed and variable. A more detailed explanation on back pressure is available in the Crosby Engineering Handbook. The bonnet is vented to monitor bellows integrity. Aside from balancing, the bellows in Style JBS may be used to isolate the spring and guiding surfaces in the valve from corrosive and dirty fluids and shield the spring from high temperature service. 6 Please refer to Warranty and Warnings on page 63. Crosby Liquid Service Valves Styles JLT-JOS and JLT-JBS Crosby Style JLT pressure relief valve for liquid service has been designed with a unique patented internal trim that provides stable non-chattering valve performance on incompressible fluid applications. This superior high performance valve for liquid service has increased capacity at 10% overpressure that often permits the use of a smaller valve with an associated reduction in piping costs. The blowdown is adjustable and an O-ring soft seat design is also available when exceptional seat tightness is required. Crosby Style JLT valves have been capacity certified on water at 10% overpressure and meet all the requirements of ASME Code Section VIII. Style JLT-JOS Style JLT-JBS Crosby Style JOS-H Style JOS-H with open bonnet and Type C regular lifting lever is available for ASME Code Section VIII steam applications. Only the bonnet need be changed to convert a Style JOS Type C to Style JOS-H. With the open bonnet feature, carbon steel spring material can be used to +650F (+343C). Style JOS-H Please refer to Warranty and Warnings on page 63. 7 JOS, JBS and JLT Style Designations Size Inlet x Orifice x Outlet 1" D 2" thru 8" T2 10" (5) Pressure/Temperature Inlet Flange Range Ratings Style JOS-Conventional JBS- With bellows JLT-JOS-Conventional with liquid trim(1) JLT-JBS-Bellows with liquid trim(1) JBS-BP-Bellows with back pressure balancing piston JLT-JBS-BP - Bellows with liquid trim and back pressure balancing piston(1) JOS-H - Conventional JOS with open bonnet for ASME Code Section VIII steam service to +650F(+343C)(2) Material Variations (3) (4) 2 - -450F to -76F (-268C to -60C) 4 - -75F to -21F (-59C to -30C) 5*- -20F to +450F (-29C to +232C) 6 - +451F to +800F (+233C to +427C) *Except "T" and "T2" 7 - +801F to +1000F orifice is Cl 300 (+428C to +538C) flange None - Standard Materials S - All 316 St.St. S4 - All 316 St.St. except body, bonnet, cap and spring M - All Monel with Monel or Inconel spring M1 - Monel nozzle and disc insert M4 - All Monel except body, bonnet, cap, spring and washers M5 - All Monel except spring and washers H - All Hastelloy C H1 - Hastelloy C nozzle and disc insert H4 - All Hastelloy C except body, bonnet, cap, spring and washers H5 - All Hastelloy C except spring and washers 1 - Cl 150 Flange 2 - Cl 300 Flange 3 - Cl 300 Flange 4*- Cl 600 Flange 5 - Cl 900 Flange 6 - Cl 1500 Flange 7 - Cl 2500 Flange *Except for Style JOS-H with open bonnet, carbon steel spring may be used to +650F(+343C) When ordering soft seats, specify material. Caps and Lifting Levers (Type) Type J - (Standard) screwed cap Type K - Screwed cap with test rod Type C- Regular lifting lever(6) Type D- Packed lifting lever(6) Type E- Packed lifting lever with test rod(6) Type L- Bolted cap Type M- Bolted cap with test rod Special top constructions are also available such as Type F - Air Operated Lifting Device Optional Caps for Height Restricted Applications Type A- Screwed cap Type B- Screwed cap with test rod Type G- Bolted cap Type H- Bolted cap with test rod Available Options: O-ring soft seats Flange facings such as ring type joint Sour gas service materials and certifications Special Cl 300 outlets (where not standard) Special Teflon (FEP) bellows coating Special spring coatings or plating Block bodies Bonnet and cap inside painting or plastic coating Bug screens Special materials not cataloged Flanges to international standards Special flanges Stellited nozzle and disc insert Special casting or machined surface tests Special cleaning Special painting or coatings Special Testing Steam jacketed bodies Supplementary loading CAUTION! Refer to pages 14 through 43 to verify that the JOS/JBS/JLT model number specified is available in the size, style and pressure/temperature rating combination selected. How to Order Examples: (1) To specify a G orifice (0.503 sq.in.) (325 sq.mm) Style JOS conventional valve with standard materials for liquid service at 700 psig (48.2 barg) and at +700F (+371C) with a packed lifting lever, the following designation applies: 1-1/2 G 2-1/2 JLT-JOS-46 - D (2) To specify an M orifice (3.60 sq.in.)(2323 sq.mm) Style JBS bellows valve with back pressure balancing piston, Monel nozzle and disc insert, and Kalrez O-ring soft seats for gas service at 200 psig (13.7 barg) and +400F (+204C) with screwed cap and test rod, the following designation applies: 4M6 JBS-BP-25-M1 - K with Kalrez (3) To specify a K orifice (1.838 sq.in.)(1186 sq.mm) Style JOS conventional valve with open bonnet and standard materials for ASME Code Section VIII steam service at 600 psig (41.3 barg) and +600F (+316C) with a regular lifting lever, the following designation applies: 3K4 JOS-H-45-C 8 Please refer to Warranty and Warnings on page 63. Notes: (1) Style designations "JLT-JOS," "JLT-JBS," or "JLT-JBS-BP" signify Styles JOS, JBS or JBS-BP with liquid trim for liquid service. (2) Upper temperature limit is +650F (+343C) for Style JOS-H open bonnet valve for ASME Code Section VIII steam service. (3) See pages 14-43 for appropriate maximum set pressures and temperatures. (4) See pages 10-13 for complete listings of materials of construction. (5) Larger sizes are available. Ask for Catalog No. 307. (6) ASME Code Section VIII rules require that pressure relief valves for water service over +140F (+60C), steam and air shall have a lifting device. O-Ring Soft Seat Materials and Pressure/Temperature Limits SET PRESSURE barg 1.03 500 6.90 34.5 69.0 Kalrez (90) TFE 102 TFE 400 204 Kalrez (80) Silicone (80) Viton (75) TFE 300 200 Kalrez (90) Viton (90) TFE 93 Buna N(70) EPR (80) Kalrez (80) Silicone (70) Viton (75) TFE 100 50 Buna N (90) EPR (90) Kalrez (90) Viton (90) TFE Buna N (60) EPR (70) Silicone (50) 0 -50 -150 15 260 100 Buna N (70) EPR (70) Silicone (70) TFE Buna N(90) EPR (90) Silicone (80) TFE TFE TFE 200 300 400 500 600 700 800 900 1000 -17 -45 1200 1400 -101 SET PRESSURE psig EPR = Ethylene Propylene Rubber Note: Other soft seat materials are available on request. For O-ring seats below -150F (-101C) consult Crosby. For steam service, metal-to-metal seats are recommended; consult Crosby if soft seats are required. MAXIMUM SET PRESSURE LIMITS ORIFICE JLT O-Ring Soft Seat JOS/JBS O-Ring Soft Seat D E F G H J K L M N P Q R T T2 MAXIMUM SET PRESSURE psig 1480 1480 1480 1480 1480 1480 1480 1000 1100 1000 1000 600 300 300 300 Please refer to Warranty and Warnings on page 63. barg 102 102 102 102 102 102 102 68.9 75.8 68.9 68.9 41.3 20.6 20.6 20.6 9 JOS/JBS/JLT Valve Materials Standard Materials - Body/Bonnet/Spring Materials per API Standard 526(5) Ref. No. JOS/JBS ( )5 -20F to +450F (-29C to +232C) JOS/JBS ( )6 +451F to +800F (+233C to +427C) JOS/JBS ( )7 +801F to +1000F (+428C to +538C) JOS/JBS ( )4 -75F to -21F (-59C to -30C) JOS/JBS ( )2 -450F to -76F (-268C to -60C) Body Carbon Steel SA-216 Gr. WCB Carbon Steel SA-216 Gr. WCB Chrome Moly Steel SA-217 Gr. WC6 316 St.St. SA-351 Gr. CF8M 316 St. St. SA-351 Gr. CF8M Nozzle Nozzle Ring Set Screw Disc Holder Disc Holder Bellows Top Flange(12) Bellows Disc Insert Retainer Screw(s) O-Ring Retainer O-Ring (7) Guide Spindle Spindle Cotter Pins 316 St.St. 316 St.St. 416 St.St. 316L St.St. 316L St.St. 316L St.St. 316L St.St. 316 St.St. (6) 316 St.St. 316 St.St. Specify St.St. (1) 416 St.St. (2) Stainless Steel 316 St.St. 316 St.St. 416 St.St. 316L St.St. 316L St.St. 316L St.St. 316L St.St. 316 St.St.(6) 316 St.St. 316 St.St. Specify St.St. (1) 416 St.St. (2) Stainless Steel 316 St.St. 316 St.St. 416 St.St. 316L St.St. 316L St.St. 316L St.St. 316L St.St. 316 St.St. (6) 316 St.St. 316 St.St. Specify St.St. (1) 416 St.St. (2) Stainless Steel 316 St.St. 316 St.St. 416 St.St. 316L St.St. 316L St.St. 316L St.St. 316L St.St. 316 St.St. 316 St.St. 316 St.St. Specify St.St. (1) 416 St.St. Stainless Steel 316 St.St. 316 St.St. 316 St.St. 316L St.St. 316L St.St. 316L St.St. 316L St.St. 316 St.St. 316 St.St. 316 St.St. Specify St.St. (1) 316 St.St. Stainless Steel Carbon St. (3) Alloy St. (3)(8) Alloy St. (3)(8) Part Name 1 2 3 4 + 5 +• 5A +• 5B +• 5C +6, +6A + 6B + 6C + 7 8 9 9A 10 Spring 11 Spring Washer(s) 12 Bonnet 13 14 15 16 17 + 20 + 21 22 Bonnet Stud Bonnet Nut Adjusting Bolt Adj. Bolt Nut Pipe Plug (Bonnet) Set Screw Gasket Guide Gasket Seal & Wire 23 24 + 25 Seal Clip Type J Cap Cap Gasket Carbon St. (3) 316 St.St. Steel Steel Steel Steel 316 St.St. Carbon St. SA-216 Gr. WCB Carbon St. SA-216 Gr. WCB Chrome Moly St. SA-217 Gr. WC6 316 St.St. SA-351 Gr. CF8M 316 St.St. SA-351 Gr. CF8M Alloy St.(4) Steel 416 St.St. Steel Steel Alloy St. (4) Steel 416 St.St. Steel Steel Alloy St. (4) Steel 416 St.St. Steel Steel 304 St.St. 304 St.St. 416 St.St. 316 St.St. 316 St.St. 304 St.St. 304 St.St. 316 St.St. 316 St.St. 316 St.St. * * * * * * * * * * Lead & St.St. St.St. Carbon St. Lead & St.St. St.St. Carbon St. Lead & St.St. St.St. Carbon St. Lead & St.St. St. St. 316 St.St. Lead & St.St. St. St. 316 St.St. * * * * * 6C 24 23 22 25 15 6A 7 16 11 12 10 Note: This vent must remain open on JBS construction 17 (JOS only) 9 13 21 14 21 6B 2 Style JLT O-Ring Soft Seat 21 8 5B 6 20 5 4 3 9A 5C 5A 22 1 2 Style JOS 10 Cotter pins used in L orifice and above only. Please refer to Warranty and Warnings on page 63. Style JBS (with bellows) Variations From Standard Materials Monel 316 Stainless Steel ( )( ) S4 ( )( ) S ( )( ) M1 Carbon Steel SA-216 Gr. WCB 316 St.St. SA-351 Gr. CF8M Carbon Steel SA-216 Gr. WCB 316 St.St. 316 St.St. 316 St.St. 316L St.St. 316L St.St. 316L St.St. 316L St.St. 316 St.St.(6) 316 St.St. 316 St.St. Specify St.St.(1) 316 St.St. Stainless Steel Carbon St.(3) or Alloy Steel (3)(8) 316 St.St. 316 St.St. 316 St.St. 316 St.St. 316L St.St. 316L St.St. 316L St.St. 316L St.St. 316 St.St. (6) 316 St.St. 316 St.St. Specify St.St. (1) 316 St.St. Stainless Steel 316 St.St. or Inconel X750 (10) 316 St.St. ( )( ) M4 Hastelloy ( )( ) M5 ( )( ) M Carbon St. Monel Monel SA-216 ASTM A 494 ASTM A 494 Gr. WCB Gr. M35-1(11) Gr. M35-1(11) Monel Monel Monel 316 St.St. Monel Monel 416 St.St. Monel Monel 316L St.St. Monel Monel 316L St.St. Monel Monel 316L St.St. Monel Monel 316L St.St. Monel Monel Monel Monel Monel Monel Monel Monel Monel Monel Monel Specify Specify Specify St.St. (1) Monel Monel 416 St.St.(2) Monel Monel Stainless Monel Monel Steel Carbon St.(3) Carbon St. Carbon St. or Nickel Nickel Alloy St.(3)(8) Plated (9) Plated (9) Steel 316 St.St. 316 St.St. Monel Monel Monel Monel Monel Monel Monel Monel Monel Monel Specify Monel Monel Monel Monel or Inconel X750 Monel ( )( ) H1 Carbon St. SA-216 Gr. WCB Hast. C 316 St.St. 416 St.St. 316L St.St. 316L St.St. 316L St.St. 316L St.St. Hast. C Hast. C Hast. C Specify St.St. (1) 416 St.St.(2) Stainless Steel Carbon St. (3) or Alloy St.(3)(8) Steel ( )( ) H4 ( )( ) H5 ( )( ) H Ref. No. Carbon St. Hast. C Hast. C SA-216 SA-494 SA-494 Gr. WCB Gr. CW-12MW Gr. CW-12MW Hast. C Hast. C Monel Hast. C Hast. C Hast. C Hast. C Hast. C Hast. C Hast. C Specify Hast. C Monel Monel Hast. C Hast. C Hast. C Hast. C Hast. C Hast. C Hast. C Hast. C Hast. C Hast. C Specify Hast. C Hast. C Hastelloy or Monel Carbon St. Carbon St. Nickel Nickel Plated (9) Plated (9) 316 St.St. 316 St.St. 1 Hast. C 2 Hast. C 3 Hast. C 4 Hast. C + 5 Hast. C + • 5A Hast. C + • 5B Hast. C + • 5C Hast. C +6,+6A Hast. C + 6B Hast. C + 6C Specify + 7 Hast. C 8 Hast. C 9 Hastelloy 9A or Monel Hast. C 10 Hast.C 11 Carbon St. SA-216 Gr. WCB 316 St. St. SA-351 Gr. CF8M Carbon St. SA-216 Gr. WCB Carbon St. Monel Monel SA-216 ASTM A 494 ASTM A 494 Gr. WCB Gr. M35-1(11) Gr. M35-1 (11) Carbon St. SA-216 Gr. WCB Carbon St. Hast. C Hast. C SA-216 SA-494 SA-494 Gr. WCB Gr. CW-12MW Gr. CW-12MW 12 Alloy St.(4) Steel 316 St.St. 316 St.St. Steel 304 304 316 316 316 Alloy St.(4) Steel 416 St. St. Steel Steel Alloy St. (4) 304 St.St. Steel 304 St.St. Monel Monel Monel Monel Steel Monel 304 St.St. 304 St.St. Monel Monel Monel Alloy St. (4) Steel 416 St.St. Steel Steel Alloy St. (4) Steel Monel Monel Steel Hast. C Hast. C Hast. C Hast. C Hastelloy Hast. C Hast. C Hast. C Hast. C Hastelloy 13 14 15 16 17 20 21 22 St.St. St.St. St.St. St.St. St.St. * * * * * * * * * * * * * * * * * * * * Lead & St.St. St.St. Carbon St. Lead & St.St. St.St. 316 St.St. Lead & St.St. St.St. Carbon St. Lead & St.St. St.St. Carbon St. Lead & St.St. St.St. Monel Lead & St.St. St. St. Monel Lead & St.St. St.St. Carbon St. Lead & St.St. St.St. Carbon St. Lead & St.St. St.St. Hast. C Lead & St.St. St.St. Hast. C * * * * * * * * * * + + + 23 24 25 Subassembly + Recommended spare parts * Organic fiber non-asbestos (1) Corrosion resistant stainless steel ASTM A 297 Gr. HE (2) 17-4PH Spindle Point on D and E orifice Style JBS ( )5, 6 and 7 valves only. (3) Corrosion resistant coating. (4) ASME SA 193 Gr. B7 (5) Crosby may upgrade to an alternative material. (6) 17-4PH stainless steel for steam service above 450 psig (31.03 barg). (7) See page 9 for O-ring soft seat materials and pressure/temperature limits. (8) Crosby may upgrade to Inconel X750. (9) For temperatures above +450F (+232C), Crosby will supply either alloy steel nickel plated or Inconel X750 springs. (10) Temperature limit for 316 stainless steel spring is +450F (+232C). (11) Permitted by ASME Code Case 1750-10 (12) Top flange on D and E orifice bellows is 316 stainless steel. Note: Cotter pins used to lock spindle into disc holder are in L orifice and above only. Please refer to Warranty and Warnings on page 63. 11 Caps and Lifting Levers DOG SHAFT LEVER NUT LEVER NUT LOCKWASHER PACKING GLAND SLEEVE PACKING GLAND NUT CAP LEVER PACKING GLAND PACKING CAP DOG SHAFT GASKET SPINDLE SEAL & WIRE CAP PLUG CAP GASKET CAP PLUG GASKET Screwed Cap Type A Type J (Standard) TEST ROD Packed Lifting Lever Type D (Top View of Packing Gland construction used for special materials) CAP OR CAP TOP SPINDLE CAP Type Type Type Type Type CAP SPINDLE B E H K M LEVER NUT Cap and Test Rod - Screwed Cap - Packed Lifting Lever - Bolted Cap - Screwed Cap (Standard) - Bolted Cap (Standard) LEVER LOCKWASHER DOG SHAFT BEARING DOG SHAFT GASKET O-RING CAP STUD NUT CAP STUD CAP SEAL & WIRE DOG VALVE SPINDLE Bolted Cap Type G Type L (Standard) Packed Lifting Lever Type D Top View CAP CAP TOP SPINDLE NUT COTTER PIN FORKED LEVER COTTER PIN CAP TOP GASKET SPINDLE NUT COTTER PIN DOG PIN CAP DOG SHAFT ▲ CAP STUD SPINDLE PIN CAP STUD NUT ADJUSTING BOLT ADJ. BOLT NUT CAP SET SCREW LEVER Regular Lifting Lever Type C 12 Please refer to Warranty and Warnings on page 63. CAP GASKET Packed Lifting Lever Type D SEAL & WIRE Styles JOS/JBS/JLT pressure relief valves are regularly furnished with closed bonnet and screwed cap over the adjusting bolt. The following types of top construction are available except where otherwise indicated. Screwed Cap (Type J Standard) - Where no lifting lever is required. TEST RODS: Types K, E or M - Valves with screwed caps, packed lifting levers or bolted caps can be fitted to accommodate test rods which will hold the valve closed when the equipment on which they are installed is hydrostatically tested. Type J screwed cap changes to Type K with test rod. Bolted Cap (Type L) - Where no lifting lever is required. Available on special order. Type D packed lifting lever changes to Type E with test rod. LIFTING LEVERS: Type L bolted cap changes to Type M with test rod. Regular (Type C) - for steam and air service where the valve cap is not required to be tight on the discharge side and where conditions are such that periodic testing is desirable. Regular lifting levers may be furnished with a supplementary gagging device on special order. Packed (Type D) - For services where tightness on the discharge side is necessary and where conditions are such that periodic testing is desirable. Also recommended for hot water services. Caps and Lifting Lever Materials STANDARD MATERIAL Ref. No. Part Name HEIGHT RESTRICTED APPLICATIONS: For applications where there are height restrictions, cap types A,B,G and H are available. CAUTION: Test rods should never be tightened more than fingertight. Overtightening may damage internal parts. Moreover, a test rod should never be kept on the valve during operation of the equipment. During normal operation the test rod is replaced with cap plug and gasket to maintain tightness on the discharge side. VARIATIONS FROM STANDARD MATERIALS JOS/JBS-( )5,6,7 JOS/JBS-( )4 JOS/JBS-( )2 -20F to +1000F -75F to -21F -450F to -76F (-29C to +538C) (-59C to -30C) (-268C to -60C) ( )( )S ( )( )S4 ( )( )M & ( )( )M5† ( )( )M4 & ( )( )H4† ( )( )H & ( )H5† 24 Cap(J,K,D, Carbon 316 St.St. 316 St.St. 316 St.St. Carbon Monel Carbon Hastelloy C E,L and M) Steel Steel Steel Cap (C) Malleable Iron Malleable Iron 316 St.St. 316 St.St. Malleable Iron Monel Malleable Iron Hastelloy C 36 Cap Top(D,E) Steel 316 St.St. 316 St.St. 316 St.St. Steel Monel Steel Hastelloy C 31 Cap Set Screw(C) St.St. St.St. St.St. St.St. St.St. St.St. St.St. Hastelloy C 40 Cap Stud Alloy Steel 304 St.St. 304 St.St. 304 St.St. Alloy Steel 304 St.St. Alloy Steel Hastelloy C 41 Cap Stud Nut Steel 304 St.St. 304 St.St. 304 St.St. Steel 304 St.St. Steel Hastelloy C 48 Lever (D & E) Steel Steel 316 St.St. 316 St.St. Steel 316 St.St. Steel 316 St.St. 32, Lever(C), Malleable Iron Malleable Iron 316 St.St. 316 St.St. Malleable Iron 316 St.St. Malleable Iron 316 St.St. 35 Forked Lever (C) 33 Pin(Lever, Steel Steel St.St. St.St. Steel 316 St.St. Steel St.St. Forked Lever) 34 Cotter Pins Steel Steel St.St. St.St. Steel St.St. Steel St.St. 49 Lever Nut Steel Steel 316 St.St. 316 St.St. 316 St.St. St.St. 316 St.St. 316 St.St. (D&E) 50 Lever Nut Steel Steel St.St. St.St. Steel St.St. Steel St.St. Lockwasher 30 Spindle Nut Steel Steel 316 St.St. 316 St.St. 316 St.St. Monel Monel Hastelloy C 38 Dog Steel Steel 316 St.St. 316 St.St. 316 St.St. Monel Monel Hastelloy C 39 Dog Shaft 416 St.St. 416 St.St. 316 St.St. 316 St.St. 316 St.St. Monel Monel Hastelloy C 46 Dog Shaft 416 St.St. 416 St.St. Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 Bearing 45 Dog Shaft Viton Viton Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 Bearing O-Ring 57 Packing Gland Note 1 Note 1 316 St.St. 316 St.St. 316 St.St. Monel Monel Monel 58 Packing Note 1 Note 1 316 St.St. 316 St.St. 416 St.St. Monel 416 St.St. Monel Gland Sleeve 59 Packing Note 1 Note 1 316 St.St. 316 St.St. Steel Monel Steel Monel Gland Nut 56 Packing Note 1 Note 1 Teflon Teflon Teflon Teflon Teflon Teflon 27 Test Rod (K,E,M) 416 St.St. 416 St.St. 416 St.St. 416 St.St. 416 St.St. 416 St.St. 416 St.St. 416 St.St. 28 Cap Plug (K,E,M) 416 St.St. 416 St.St. 316 St.St. 316 St.St. 416 St.St. Monel 416 St.St. Hastelloy C 25,29 Gaskets 37,47 * * * * * * * * †Special material valves ( )( )M1 and ( )( )H1 use caps and lifting gear of standard materials. Organic Fiber Non-Asbestos *Note 1: Packing gland construction is standard for special material valves. Please refer to Warranty and Warnings on page 63. 13 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H D Orifice 0.110 sq. in. (71 sq. mm) Effective Area Valve Size Inlet x Orifice x Outlet Valve Style JOSJBSJLT*JOS-H- Back Press. Limit @100F psig Maximum Set Pressure - psig Standard Connections ANSIFlanges RaisedFace Inlet Inlet Outlet -450F to -76F -75F -20F to to -21F +100F * +450F +800F +1000F 153 255 413 ) 600 600 740 600 600 600 16 26 36 46 150 300 300 600 150 150 150 150 185 285 615 1235 80 285 410 825 285 285 285 285 230 230 230 230 56 11/2D2 900 66 11/2D2 1500 76 11/2D21/2 2500 300 300 300 1845 1235 3080 2060 5135 3430 600 600 740 600 600 600 37 47 300 600 150 150 510 1015 225 445 285 285 230 230 JOSJBSJLT- 57 11/2D2 900 67 11/2D2 1500 77 11/2D21/2 2500 300 300 300 1525 670 2540 1115 4230 1860 600 600 740 600 600 600 JOSJBSJLT- 14 24 34 44 1D2 1D2 1D2 1D2 150 300 300 600 150 150 150 150 275 275 275 275 230 230 230 230 JOSJBSJLT- 12 22 32 42 1D2 1D2 1D2 1D2 150 300 300 600 150 275 150 275 150 720 150 1440 275 275 275 275 230 230 230 230 1D2 1D2 275 275 720 1440 -29C * to +232C +427C +538C +38C 19.6 19.6 51.0 102 2220) 1845 3705) 3080 6000) 5135 JOSJBSJLTJOS-H- -59C to -30C 230 230 230 230 300 300 300 JOSJBSJLT- -268C to -60C 285 285 285 285 55 11/2D2 900 65 11/2D2 1500 1 1 75 1 /2D2 /2 2500 1D2 1D2 1D2 1D2 Inlet JBS † 285) 185 285) 285 740) 615 1480) 1235 ) Maximum Set Pressure - barg JOS † 150 150 150 150 JOSJBSJLTJOS-H- 1D2 1D2 1D2 1D2 Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) 150 300 300 600 JOSJBSJLT- 15 25 35 45 Low Set Pressure Limits: JOS = 10 psig (0.68 barg) JBS = 25 psig (1.72 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) 12.7 19.6 42.4 85.1 127 212 354 12.7 19.6 42.4 85.1 127 212 354 Back Press. Limit@38C barg JOS † JBS † 19.6 19.6 19.6 19.6 15.8 15.8 15.8 15.8 41.3 41.3 41.3 41.3 51.0 41.3 5.51 19.6 28.2 56.8 85.1 142 236 19.6 19.6 19.6 19.6 15.8 15.8 15.8 15.8 41.3 41.3 41.3 41.3 51.0 41.3 35.1 15.5 19.6 15.8 69.9 )30.6 19.6 15.8 105 175 291 18.9 18.9 49.6 99.2 ) 18.9 18.9 ) 49.6 99.2 46.1 41.3 41.3 76.8 41.3 41.3 128 51.0 41.3 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style JOSJBSJLTJOS-H- JOSJBSJLT- 14 12,14,15,16, 22,24,25,26 32,34,35,36,37 42,44,45,46,47 55,56,57,65,66,67 75,76,77 D Orifice Valve Dimensions - in. (mm) Center to Face Use To Approximate Height Inlet Outlet Find Bolt Length Valve (Cap) Type E F X J&L C D 4-1/8 (105) 4-1/8 (105) 4-1/8 (105) 4-1/8 (105) 5-1/2 (140) 4-1/2 (114) 4-1/2 (114) 4-1/2 (114) 5-1/2 (140) 6-1/2 (165) 1-9/16 (40) 1-9/16 (40) 1-9/16 (40) 2 (51) 2-1/2 (64) 19-3/4 (502) 19-3/4 (502) 19-3/4 (502) 20-1/2 (521) 21-3/4 (552) Please refer to Warranty and Warnings on page 63. 19 (483) 19 (483) 19 (483) 19-3/4 (502) 21 (533) 19-1/2 (495) 19-1/2 (495) 19-1/2 (495) 20-1/4 (514) 21-1/2 (546) Approx. Weight lbs(kg) Type J 36 (16) 36 (16) 36 (16) 65 (29) 75 (34) TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart - To ANSI Cl 600 SET PRESSURE - barg 1000 500 900 D Orifice 0.110 sq. in. (71 sq.mm) Effective Area 800 400 700 600 300 500 400 200 300 100 200 100 0 0 • -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Pressure-Temperature Limit Chart - ANSI Cl 900, Cl 1500, Cl 2500 SET PRESSURE - barg SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 15 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H E Orifice 0.196 sq. in. (126 sq. mm) Effective Area ValveSize Inlet x Orifice x Outlet Valve Style JOSJBSJLT*JOS-HJOSJBSJLTJOSJBSJLTJOS-HJOSJBSJLTJOSJBSJLTJOS-H- 15 25 35 45 1E2 1E2 1E2 1E2 Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) Standard Connections ANSIFlanges Raised Face Inlet Outlet 150 300 300 600 1E2 1E2 1E2 1E2 150 300 300 600 Inlet -450F to -76F -75F -20F to to -21F +100F 150 150 150 150 285) 285) 740) 1480) 150 150 150 150 56 11/ 2E2 900 300 66 11/ 2E2 1500 300 76 11/2E21/2 2500 300 37 47 1E2 1E2 Back Press. Limit@100F psig Maximum Set Pressure - psig 55 11/ 2E2 900 300 65 11/ 2E2 1500 300 75 11/2E21/2 2500 300 16 26 36 46 Low Set Pressure Limits: JOS = 8 psig (0.55 barg) JBS = 25 psig (1.72 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) 300 150 600 150 JOSJBSJLT- 57 11/ 2E2 900 300 67 11/ 2E2 1500 300 77 11/2E21/2 2500 300 JOSJBSJLT- 14 24 34 44 1E2 1E2 1E2 1E2 150 300 300 600 150 150 150 150 JOSJBSJLT- 12 22 32 42 1E2 1E2 1E2 1E2 150 300 300 600 150 275 150 275 150 720 150 1440 * Inlet -268C to -60C -59C to -30C -29C * to +232C +427C +538C +38C +450F +800F +1000F JOS † JBS † 185 285 615 1235 285 285 285 285 230 230 230 230 19.6 19.6 51.0 102 153 255 413 ) 2220) 1845 3705) 3080 6000) 5135 ) 600 600 740 600 600 600 185 285 615 1235 80 285 410 825 285 285 285 285 230 230 230 230 1845 1235 3080 2060 5135 3430 600 600 740 600 600 600 510 1015 225 285 445 285 230 230 1525 670 600 2540 1115 600 4230 1860 740 600 600 600 275 275 275 275 230 230 230 230 275 275 275 275 230 230 230 230 275 275 720 1440 Back Press. Limit @38C barg Maximum Set Pressure - barg 12.7 19.6 42.4 85.1 127 212 354 JBS † 19.6 19.6 19.6 19.6 15.8 15.8 15.8 15.8 41.3 41.3 41.3 41.3 51.0 41.3 12.7 19.6 42.4 85.1 127 212 354 5.51 19.6 28.2 56.8 ) 18.9 ) 18.9 49.6 99.2 19.6 19.6 19.6 19.6 15.8 15.8 15.8 15.8 85.1 142 236 41.3 41.3 41.3 41.3 51.0 41.3 35.1 69.9 15.5 19.6 15.8 30.6 19.6 15.8 ) 105 175 291 18.9 18.9 49.6 99.2 JOS † 46.1 41.3 41.3 76.8 41.3 41.3 128 51.0 41.3 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style 12,14,15,16, 22,24,25,26 32,34,35,36,37 JOSJBSJLTJOS-H- 42,44,45,46,47 JOSJBSJLT- 16 55,56,57,65,66,67 75,76,77 Valve Dimensions - in. (mm) Center to Face Use To Approximate Height Inlet Outlet Find Bolt Length Valve (Cap) Type E F X J&L C D 4-1/8 4-1/2 1-9/16 19-3/4 19 19-1/2 (105) (114) (40) (502) (483) (495) 4-1/8 4-1/2 1-9/16 19-3/4 19 19-1/2 (105) (114) (40) (502) (483) (495) 4-1/8 4-1/2 1-9/16 19-3/4 19 19-1/2 (105) (114) (40) (502) (483) (495) 4-1/8 5-1/2 2 20-1/2 19 3/4 20-1/4 (105) (140) (51) (521) (502) (514) 5-1/2 6-1/2 2-1/2 21-3/4 21 21-1/2 (140) (165) (64) (532) (533) (546) Please refer to Warranty and Warnings on page 63. E Orifice Approx. Weight lbs(kg) Type J 36 (16) 36 (16) 36 (16) 65 (29) 75 (34) TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart - To ANSI Cl 600 E Orifice 0.196 sq. in. (126 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 • -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Pressure-Temperature Limit Chart - ANSI Cl 900, Cl 1500, Cl 2500 SET PRESSURE - barg SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 17 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H F Orifice 0.307 sq. in. (198 sq. mm) Effective Area Valve Style JOSJBSJLT*JOS-HJOSJBSJLTJOSJBSJLTJOS-HJOSJBSJLTJOSJBSJLTJOS-H- 15 25 35 45 Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) ValveSize Inlet x Orifice x Outlet Standard Connections ANSIFlanges RaisedFace 11/2F2 11/2F2 11/2F2 11/2F2 150 300 300 600 Inlet Inlet Outlet -450F to -76F -75F -20F to to -21F +100F * +450F +800F +1000F 285) 185 285) 285 740) 615 1480) 1235 55 1 /2F2 /2 900 300 65 11/2F21/2 1500 300 75 11/2F21/2 2500 300 2220) 1845 3705) 3080 5000) 5000 ) 185 285 615 1235 80 285 410 825 16 26 36 46 1 11/2F2 11/2F2 11/2F2 11/2F2 150 300 300 600 150 150 150 150 56 11/2F21/2 900 300 66 11/2F21/2 1500 300 76 11/2F21/2 2500 300 37 47 11/2F2 11/2F2 57 11/2F21/2 900 300 67 11/2F21/2 1500 300 77 11/2F21/2 2500 300 JOSJBSJLT- 14 24 34 44 12 22 32 42 11/2F2 11/2F2 11/2F2 11/2F2 1 1 /2F2 11/2F2 11/2F2 11/2F2 150 300 300 600 150 150 150 150 150 300 300 600 150 275 150 275 150 720 150 1440 ) 510 1015 JOS † JBS † 285 285 285 285 230 230 230 230 285 285 285 285 Inlet -268C to -60C -59C to -30C -29C * to +232C +427C +538C +38C 19.6 19.6 51.0 102 153 255 344 1525 670 2540 1115 4230 1860 740 500 740 500 740 500 275 275 720 1440 275 275 275 275 230 230 230 230 275 275 275 275 230 230 230 230 JBS † 19.6 19.6 19.6 19.6 15.8 15.8 15.8 15.8 51.0 51.0 51.0 34.4 34.4 34.4 5.5 19.6 28.2 56.8 19.6 19.6 19.6 19.6 15.8 15.8 15.8 15.8 85.1 142 236 51.0 51.0 51.0 34.4 34.4 34.4 35.1 69.9 15.5 19.6 30.6 ) 19.6 15.8 15.8 46.1 51.0 76.8 51.0 128 51.0 34.4 34.4 34.4 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 12.7 19.6 42.4 85.1 12.7 19.6 42.4 85.1 740 500 740 500 740 500 285 230 285 230 JOS † 127 212 344 230 230 230 230 225 445 Back Press. Limit @38C barg Maximum Set Pressure - barg 740 500 740 500 740 500 1845 1235 3080 2060 5000 3430 300 150 600 150 JOSJBSJLT- JOSJBSJLT- Back Press. Limit@100F psig Maximum Set Pressure - psig 150 150 150 150 1 Low Set Pressure Limits: JOS = 5 psig (0.34 barg) JBS = 10 psig (0.68 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) 127 212 344 105 175 291 18.9 18.9 49.6 99.2 ) 18.9 18.9) 49.6 99.2 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style 12,14,15,16 22,24,25,26 32,34,35,36,37 JOSJBSJLTJOS-H- 42,44,45,46,47 55,56,57,65,66,67 75,76,77 18 F Orifice Valve Dimensions - in. (mm) Center to Face Use To Approximate Height Inlet Outlet Find Bolt Length Valve (Cap) Type E F X J&L C D 4-7/8 (124) 4-7/8 (124) 4-7/8 (124) 4-7/8 (124) 5-1/2 (140) 4-3/4 (121) 6 (152) 6 (152) 6 (152) 6-1/2 (165) 1-3/4 (44) 1-3/4 (44) 1-3/4 (44) 2 (51) 2-1/2 (64) 23-1/4 (591) 23-1/4 (591) 23-1/4 (591) 23 (584) 26-3/4 (679) Please refer to Warranty and Warnings on page 63. 22-1/2 (572) 22-1/2 (572) 22-1/2 (572) 21-1/4 (540) 26 (660) 23-1/4 (597) 23-1/4 (591) 23-1/4 (591) 21-3/4 (552) 26-3/4 (679) Approx. Weight lbs(kg) Type J 50 (23) 50 (23) 50 (23) 65 (29) 85 (39) TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart - To ANSI Cl 600 F Orifice 0.307 sq. in. (198 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 • -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Pressure-Temperature Limit Chart - ANSI Cl 900, Cl 1500, Cl 2500 SET PRESSURE - barg SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 19 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H G Orifice 0.503 sq. in. (325 sq. mm) Effective Area JOSJBSJLT*JOS-HJOSJBSJLTJOSJBSJLTJOS-HJOSJBSJLTJOSJBSJLTJOS-H- Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) ValveSize Inlet x Orifice x Outlet Valve Style 15 25 35 45 11/2G21/2 11/2G21/2 11/2G21/2 11/2G21/2 Standard Connections ANSIFlanges RaisedFace Inlet Outlet -450F to -76F -75F -20F to to -21F +100F * +450F +800F +1000F 55 1 /2G2 /2 900 300 65 2G3 1500 300 75 2G3 2500 300 2220) 1845 3705) 3080 3705) 3705 ) 185 285 615 1235 80 285 410 825 1 11/2G21/2 11/2G21/2 11/2G21/2 11/2G21/2 150 300 300 600 150 150 150 150 56 11/2G21/2 900 300 66 2G3 1500 300 76 2G3 2500 300 37 11/2G21/2 47 11/2G21/2 57 11/2G21/2 900 300 67 2G3 1500 300 77 2G3 2500 300 JOSJBSJLT- 14 24 34 44 12 22 32 42 11/2G21/2 11/2G21/2 11/2G21/2 11/2G21/2 1 1 1 /2G2 /2 11/2G21/2 11/2G21/2 11/2G21/2 150 300 300 600 150 150 150 150 150 300 300 600 150 275 150 275 150 720 150 1440 ) 510 1015 JOS † JBS † 285 285 285 285 230 230 230 230 Maximum Set Pressure - barg -268C -59C to to -60C -30C 285 285 285 285 Inlet -29C * to +232C +427C +538C +38C 19.6 19.6 51.0 102 740 470 740 470 740 470 1845 1235 3080 2060 3705 3430 300 150 600 150 JOSJBSJLT- JOSJBSJLT- Inlet 285) 185 285) 285 740) 615 1480) 1235 16 26 36 46 150 300 300 600 Back Press. Limit@100F psig Maximum Set Pressure - psig 150 150 150 150 1 Low Set Pressure Limits: JOS = 5 psig (0.34 barg) JBS = 15 psig (1.03 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) 153 255 255 127 212 255 230 230 230 230 12.7 19.6 42.4 85.1 740 470 740 470 740 470 225 445 285 230 285 230 1525 670 2540 1115 3705 1860 740 470 740 470 740 470 275) 275) 720) 1440) 12.7 19.6 42.4 85.1 275 275 275 275 230 230 230 230 275 275 275 275 230 230 230 230 127 212 255 ) 18.9 18.9) 49.6 99.2 JOS † JBS † 19.6 19.6 19.6 19.6 15.8 15.8 15.8 15.8 51.0 32.4 51.0 32.4 51.0 32.4 5.51 19.6 28.2 56.8 19.6 19.6 19.6 19.6 15.8 15.8 15.8 15.8 85.1 142 236 51.0 32.4 51.0 32.4 51.0 32.4 35.1 69.9 15.5 19.6 15.8 30.6 ) 19.6 15.8 105 175 255 18.9 18.9 49.6 99.2 Back Press. Limit @38C barg 46.1 51.0 32.4 76.8 51.0 32.4 128 51.0 32.4 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style 12,14,15,16 22,24,25,26 32,34,35,36 37,47 42,44,45,46 JOSJBSJLTJOS-H- 55,56,57 65,66,67,75,76,77 20 Valve Dimensions - in. (mm) Center to Face Use To Approximate Height Inlet Outlet Find Bolt Length Valve (Cap) Type E F X J&L C D 4-7/8 4-3/4 1-3/4 23-1/4 22-1/2 23-1/4 (124) (121) (44) (591) (572) (591) 4-7/8 6 1-3/4 23-1/4 22-1/2 23-1/4 (124) (152) (44) (591) (572) (591) 4-7/8 6 1-3/4 23-1/4 22-1/2 23-1/4 (124) (152) (44) (591) (572) (591) 4-7/8 6 2 26 25-1/4 26 (124) (152) (51) (660) (641) (660) 6-1/8 6-3/4 2-3/4 27 26-1/4 27 (156) (171) (70) (686) (667) (686) Please refer to Warranty and Warnings on page 63. G Orifice Approx. Weight lbs(kg) Type J 50 (23) 50 (23) 50 (23) 70 (32) 90 (41) TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart - To ANSI Cl 600 G Orifice 0.503 sq. in. (325 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 • -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Pressure-Temperature Limit Chart - ANSI Cl 900, Cl 1500, Cl 2500 SET PRESSURE - barg SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 21 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H H Orifice .785 sq. in. (506 sq. mm) Effective Area Valve Style Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) ValveSize Inlet x Orifice x Outlet Inlet Outlet 150 300 300 600 150 150 150 150 285 185 285 285 740 615 1480 1235 900 150 1500 300 2220 1845 2750 2750 ) 185 285 615 1235 80 285 410 825 Standard Connections ANSIFlanges RaisedFace Inlet -450F to -76F -75F -20F to to -21F +100F * +450F +800F +1000F 15 25 35 45 11/2H3 11/2H3 2H3 2H3 JOSJBSJLT- 55 65 2H3 2H3 JOSJBSJLTJOS-H- 16 26 36 46 11/2H3 11/2H3 2H3 2H3 JOSJBSJLT- 56 66 2H3 2H3 900 150 1500 300 1845 1235 2750 2060 JOSJBSJLTJOS-H- 37 47 2H3 2H3 300 150 600 150 510 815 JOSJBSJLT- 57 67 2H3 2H3 900 150 1500 300 JOSJBSJLT- 14 24 34 44 11/2H3 11/2H3 2H3 2H3 JOSJBSJLT- 12 22 32 42 1 /2H3 11/2H3 2H3 2H3 150 300 300 600 Back Press. Limit@100F psig Maximum Set Pressure - psig JOSJBSJLT*JOS-H- 1 Low Set Pressure Limits: JOS = 5 psig (0.34 barg) JBS = 10 psig (0.68 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) 150 150 150 150 150 300 300 600 150 150 150 150 150 300 300 600 150 275 150 275 150 720 150 1440 ) JOS † JBS † 285 285 285 285 230 230 230 230 Inlet -268C -59C to to -60C -30C -29C * to +232C +427C +538C +38C 19.6 19.6 51.0 102 285 230 740 415 285 285 285 285 Back Press. Limit @38C barg Maximum Set Pressure - barg 153 189 12.7 19.6 42.4 85.1 127 189 230 230 230 230 12.7 19.6 42.4 85.1 285 230 740 415 127 189 JOS † JBS † 19.6 19.6 19.6 19.6 15.8 15.8 15.8 15.8 19.6 15.8 51.0 28.6 5.51 19.6 28.2 56.8 19.6 19.6 19.6 19.6 15.8 15.8 15.8 15.8 85.1 142 19.6 15.8 51.0 28.6 225 445 285 230 285 230 35.1 56.2 15.5 19.6 15.8 ) 30.6 19.6 15.8 1225 670 2040 1115 285 230 740 415 84.4 140 46.1 19.6 15.8 76.8 51.0 28.6 275 275 720 1440 275 275 275 275 230 230 230 230 275 275 275 275 230 230 230 230 18.9 18.9 49.6 99.2 ) 18.9 ) 18.9 49.6 99.2 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style 12,14,15,16 22,24,25,26 32,34,35,36 37,47 42,44,45,46 55,56,57,65,66,67 22 H Orifice Valve Dimensions - in. (mm) Center to Face Use To Approximate Height Inlet Outlet Find Bolt Length Valve (Cap) Type E F X J&L C D 5-1/8 (130) 5-1/8 (130) 6-1/16 (154) 6-1/16 (154) 4-7/8 (124) 4-7/8 (124) 6-3/8 (162) 6-3/8 (162) 1-11/16 (43) 1-13/16 (46) 1-13/16 (46) 2-5/16 (59) 23-1/2 (597) 23-1/2 (597) 26-3/4 (679) 28-1/4 (718) Please refer to Warranty and Warnings on page 63. 22-3/4 (578) 22-3/4 (578) 26 (660) 27-1/2 (699) 23-1/4 (591) 23-1/4 (591) 26-3/4 (679) 28-1/4 (718) Approx. Weight lbs(kg) Type J 55 (25) 60 (27) 75 (34) 110 (50) TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart - To ANSI Cl 600 H Orifice .785 sq. in. (506 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Pressure-Temperature Limit Chart - ANSI Cl 900, Cl 1500 SET PRESSURE - barg SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 23 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H J Orifice 1.287 sq. in. (830 sq. mm) Effective Area Valve Style Low Set Pressure Limits: JOS = 5 psig (0.34 barg) JBS = 9 psig (0.62 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) ValveSize Inlet x Orifice x Outlet Inlet Outlet 150 300 300 600 150 150 150 150 Standard Connections ANSIFlanges Raised Face Inlet -450F to -76F -75F -20F * to to +450F +800F +1000F -21F +100F JOSJBSJLT*JOS-H- 15 25 35 45 2J3 2J3 21/2J4 21/2J4 JOSJBSJLT- 55 65 3J4 3J4 285) 285) 740) 1480) JOSJBSJLTJOS-H- 16 26 36 46 2J3 2J3 21/2J4 21/2J4 JOSJBSJLT- 56 66 3J4 3J4 900 150 1500 300 1845 1235 2700 2060 JOSJBSJLTJOS-H- 37 47 21/2J4 21/2J4 300 150 600 150 510 815 JOSJBSJLT- 57 67 21/2J4 3J4 900 150 1500 300 JOSJBSJLT- 14 24 34 44 2J3 2J3 21/2J4 21/2J4 150 300 300 600 150 150 150 150 JOSJBSJLT- 12 22 32 42 2J3 2J3 21/2J4 21/2J4 150 300 300 600 150 150 150 150 900 150 1500 300 150 300 300 600 Back Press. Limit@100F psig Maximum Set Pressure - psig 150 150 150 150 185 285 615 1235 ) 2220) 1845 2700) 2700 ) 185 285 615 1235 80 285 410 825 JOS † JBS † 285 285 285 285 230 230 230 230 Inlet -268C -59C to to -60C -30C -29C * to +232C +427C +538C +38C 19.6 19.6 51.0 102 285 230 600 230 285 285 285 285 Back Press. Limit @38C barg Maximum Set Pressure - barg 153 186 12.7 19.6 42.4 85.1 127 186 230 230 230 230 12.7 19.6 42.4 85.1 285 230 600 230 127 186 JOS † JBS † 19.6 19.6 19.6 19.6 15.8 15.8 15.8 15.8 19.6 15.8 41.3 15.8 5.51 19.6 28.2 56.8 19.6 19.6 19.6 19.6 85.1 142 15.8 15.8 15.8 15.8 19.6 15.8 41.3 15.8 225 445 285 230 285 230 35.1 56.1 15.5 30.6 ) 19.6 15.8 19.6 15.8 1225 670 2040 1115 285 230 600 230 84.4 140 46.1 76.8 19.6 15.8 41.3 15.8 275) 275) 720) 1440) 275 275 500 625 275 275 275 275 230 230 230 230 275 275 275 275 230 230 230 230 18.9 18.9 49.6 99.2 ) 18.9 18.9) 34.4 43.0 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 18.9 18.9 18.9 18.9 15.8 15.8 15.8 15.8 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style 12,14,15,16 22,24,25,26 32,34,35,36,37,47 JOSJBSJLTJOS-H- 42,44,45,46 57 55,56,65,66,67 24 J Orifice Valve Dimensions - in. (mm) Approx. Center to Face Use To Approximate Height Weight Inlet Outlet Find Bolt lbs(kg) Length Valve (Cap) Type Type E F X J&L C D J 5-3/8 4-7/8 1-11/16 23-3/4 23-1/4 23-3/4 66 (137) (124) (43) (603) (591) (603) (30) 5-3/8 5-5/8 2-1/16 26-3/4 26 26-3/4 89 (137) (143) (52) (679) (660) (679) (40) 6-1/8 6-3/4 2-1/8 29-1/2 28-3/4 29-1/2 115 (156) (171) (54) (749) (730) (749) (52) 6-1/8 6-3/4 2-7/16 29-1/2 28-3/4 29-1/2 140 (156) (171) (62) (749) (730) (749) (64) 7-1/4 7-1/8 2-11/16 32-1/2 31-3/4 32-1/2 155 (184) (181) (68) (826) (806) (826) (70) Please refer to Warranty and Warnings on page 63. TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart - To ANSI Cl 600 J Orifice 1.287 sq. in. (830 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 • -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Pressure-Temperature Limit Chart - ANSI Cl 900, Cl 1500 SET PRESSURE - barg SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 25 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H K Orifice 1.838 sq. in. (1186 sq. mm) Effective Area ValveSize Inlet x Orifice x Outlet Valve Style Low Set Pressure Limits: JOS = 5 psig (0.34 barg) JBS = 9 psig (0.62 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) Standard Connections ANSIFlanges RaisedFace Inlet -450F to -76F -75F -20F to to -21F +100F * +450F +800F +1000F Inlet Outlet 150 300 300 600 150 150 150 150 285) 185 285) 285 740) 615 1480) 1235 900 150 1500 300 2220) 1845 2220) 2220 ) 185 285 615 1235 80 285 410 825 JOSJBSJLT*JOS-H- 15 25 35 45 3K4 3K4 3K4 3K4 JOSJBSJLT- 55 65 3K6 3K6 JOSJBSJLTJOS-H- 16 26 36 46 3K4 3K4 3K4 3K4 JOSJBSJLT- 56 66 3K6 3K6 900 150 1500 300 1845 1235 2220 2060 JOSJBSJLTJOS-H- 37 47 3K4 3K4 300 150 600 150 510 815 JOSJBSJLT- 57 67 3K4 3K6 900 150 1500 300 JOSJBSJLT- 14 24 34 44 3K4 3K4 3K4 3K4 150 300 300 600 150 150 150 150 JOSJBSJLT- 12 22 32 42 3K4 3K4 3K4 3K4 150 300 300 600 150 150 150 150 150 300 300 600 Back Press. Limit@100F psig Maximum Set Pressure - psig 150 150 150 150 ) JOS † JBS † 285 285 285 285 150 150 150 200 Maximum Set Pressure - barg Inlet -268C -59C to to -60C -30C 19.6 19.6 51.0 102 285 200 600 200 285 285 285 285 -29C * to +232C +427C +538C +38C 153 153 JOS † JBS † 19.6 19.6 19.6 19.6 10.3 10.3 10.3 13.7 19.6 41.3 13.7 13.7 5.51 19.6 28.2 56.8 19.6 19.6 19.6 19.6 10.3 10.3 10.3 13.7 85.1 142 19.6 41.3 13.7 13.7 12.7 19.6 42.4 85.1 127 153 150 150 150 200 12.7 19.6 42.4 85.1 285 200 600 200 127 153 Back Press. Limit@38C barg 225 445 285 150 285 200 35.1 15.5 56.1 30.6) 19.6 19.6 10.3 13.7 1225 670 2040 1115 285 200 600 200 84.4 46.1 140 76.8 19.6 41.3 13.7 13.7 18.9 18.9 18.9 18.9 10.3 10.3 10.3 13.7 18.9 18.9 18.9 18.9 10.3 10.3 10.3 13.7 275) 275) 720) 1440) 275 275 525 600 275 275 275 275 150 150 150 200 275 275 275 275 150 150 150 200 18.9 18.9 49.6 99.2 ) 18.9 18.9 ) 36.1 41.3 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style 12,14,15,16 22,24,25,26 32,34,35,36, 37,47 42,44,45,46 JOSJBS57 JLTJOS-H55,56 65,66,67 26 Valve Dimensions - in. (mm) Center to Face Use To Approximate Height Inlet Outlet Find Bolt Length Valve (Cap) Type E F X J&L C D 6-1/8 6-3/8 2-1/8 29-3/4 29 29-3/4 (156) (162) (54) (756) (737) (756) 6-1/8 6-3/8 2-1/8 29-3/4 29 29-3/4 (156) (162) (54) (756) (737) (756) 7-1/4 7-1/8 2-1/8 33 32-1/2 33-1/4 (184) (181) (54) (838) (826) (845) 7-1/4 7-1/8 2-5/16 33 32-1/2 33-1/4 (184) (181) (59) (838) (826) (845) 7-13/16 8-1/2 2-11/16 39 38 38-3/4 (198) (216) (68) (991) (965) (984) 7-3/4 8-1/2 2-11/16 39 38 38-3/4 (197) (216) (68) (991) (965) (984) Please refer to Warranty and Warnings on page 63. K Orifice Approx. Weight lbs(kg) Type J 116 (52) 117 (53) 160 (73) 175 (79) 185 (84) 195 (88) TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart - To ANSI Cl 600 SET PRESSURE - barg 1000 500 K Orifice 1.838 sq. in. (1186 sq.mm) Effective Area 900 800 400 700 600 300 500 200 400 300 100 200 100 0 0 -100 • -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Pressure-Temperature Limit Chart - ANSI Cl 900, Cl 1500 SET PRESSURE - barg SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 27 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H L Orifice 2.853 sq. in. (1841 sq. mm) Effective Area Valve Style Low Set Pressure Limits: JOS = 6 psig (0.41 barg) JBS = 8 psig (0.55 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) ValveSize Inlet x Orifice x Outlet Inlet Outlet Standard Connections ANSIFlanges RaisedFace Back Press. Limit@100F psig Maximum Set Pressure - psig Inlet -450F to -76F -75F -20F * to to +450F +800F +1000F -21F +100F JOS † JBS † 100 100 170 170 JOSJBSJLT*JOS-H- 15 25 35 45 3L4 3L4 4L6 4L6 150 300 300 600 150 150 150 150 285) 185 285) 285 740) 615 1000) 1000 ) 285 285 285 285 JOSJBSJLT- 55 4L6 900 150 1500) 1500 ) 285 170 JOSJBSJLTJOS-H- 16 26 36 46 3L4 3L4 4L6 4L6 150 300 300 600 150 150 150 150 185 285 615 1000 80 285 410 825 JOSJBSJLT- 56 66 4L6 4L6 900 1500 150 150 1500 1235 1500 1500 JOSJBSJLTJOS-H- 37 47 4L6 4L6 300 600 150 150 510 1000 225 445 285 170 285 170 JOSJBSJLT- 57 67 4L6 4L6 900 1500 150 150 1500 670 1500 1115 285 170 285 170 JOSJBSJLT- 14 24 34 44 3L4 3L4 4L6 4L6 150 300 300 600 150 150 150 150 JOSJBSJLT- 12 22 32 42 3L4 3L4 4L6 4L6 150 300 300 600 150 150 150 150 285 285 285 285 Inlet -268C -59C to to -60C -30C -29C * to +232C +427C +538C +38C 19.6 19.6 51.0 68.9 103 275 275 535 535 100 100 170 170 275 275 275 275 100 100 170 170 JBS † 19.6 19.6 19.6 19.6 6.89 6.89 11.7 11.7 19.6 11.7 5.51 19.6 28.2 56.8 19.6 19.6 19.6 19.6 6.89 6.89 11.7 11.7 85.1 103 19.6 19.6 11.7 11.7 35.1 68.9 15.5 19.6 30.6 ) 19.6 11.7 11.7 46.1 19.6 76.8 19.6 11.7 11.7 18.9 18.9 18.9 18.9 6.89 6.89 11.7 11.7 18.9 18.9 18.9 18.9 6.89 6.89 11.7 11.7 103 12.7 19.6 42.4 68.9 100 100 170 170 275 275 275 275 JOS † 12.7 19.6 42.4 68.9 103 103 285 170 285 170 275) 275) 720) 1000) Back Press. Limit @38C barg Maximum Set Pressure - barg 103 103 18.9 18.9 49.6 68.9 ) 18.9 18.9) 36.8 36.8 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style 12,14,15,16, 22,24,25,26 32,34,35,36,37 JOSJBSJLT- 42,44,45,46,47 JOS-H55,56,57,66,67 28 Valve Dimensions - in. (mm) Center to Face Use To Approximate Height Inlet Outlet Find Bolt Length Valve (Cap) Type E F X J&L C D 6-1/8 6-1/2 2 34 33-1/4 34 (156) (165) (51) (864) (845) (864) 7-1/16 7-1/8 2-1/8 34 34-1/4 34-1/4 (179) (181) (54) (864) (870) (870) 7-1/16 8 2-3/8 35-1/4 34-3/4 35-1/4 (179) (203) (60) (895) (883) (895) 7-3/4 8-3/4 2-15/16 39-3/4 38-3/4 39-1/2 (197) (222) (75) (1010) (984) (1003) Please refer to Warranty and Warnings on page 63. L Orifice Approx. Weight lbs(kg) Type J 152 (69) 192 (87) 226 (103) 270 (122) TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart L Orifice 2.853 sq. in. (1841 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 • -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 29 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H M Orifice 3.60 sq. in. (2323 sq. mm) Effective Area ValveSize Inlet x Orifice x Outlet Valve Style Low Set Pressure Limits: JOS = 8 psig (0.55 barg) JBS = 10 psig (0.68 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) Standard Connections ANSIFlanges RaisedFace Inlet Outlet JOSJBSJLT*JOS-H- 15 25 35 45 4M6 4M6 4M6 4M6 150 300 300 600 150 150 150 150 JOSJBSJLTJOS-H- 16 26 36 46 4M6 4M6 4M6 4M6 150 300 300 600 150 150 150 150 JOSJBSJLT- 56 4M6 JOSJBSJLTJOS-H- 37 47 4M6 4M6 JOSJBSJLT- 57 4M6 900 150 JOSJBSJLT- 14 24 34 44 4M6 4M6 4M6 4M6 150 300 300 600 150 150 150 150 JOSJBSJLT- 12 22 32 42 4M6 4M6 4M6 4M6 150 300 300 600 150 150 150 150 Back Press. Limit@100F psig Maximum Set Pressure - psig Inlet -450F to -76F -75F -20F * to to +450F +800F +1000F -21F +100F 285) 285) 740) 1100) JOS † JBS † 80 80 160 160 Maximum Set Pressure - barg -268C -59C to to -60C -30C Inlet -29C * to +232C +427C +538C +38C 19.6 19.6 51.0 75.8 12.7 19.6 42.4 75.8 Back Press. Limit@38C barg JOS † JBS † 19.6 19.6 19.6 19.6 5.51 5.51 11.0 11.0 185 285 615 1100 ) 285 285 285 285 185 285 615 1100 80 285 410 825 285 285 285 285 80 80 160 160 12.7 19.6 42.4 75.8 5.51 19.6 28.2 56.8 19.6 19.6 19.6 19.6 5.51 5.51 11.0 11.0 900 150 1100 1100 285 160 75.8 75.8 19.6 11.0 300 150 600 150 510 1015 225 445 285 285 160 160 35.1 69.9 15.5 30.6 19.6 19.6 11.0 11.0 1100 670 285 160 75.8 46.1 19.6 11.0 275 275 275 275 80 80 160 160 18.9 18.9 18.9 18.9 5.51 5.51 11.0 11.0 275 275 275 275 80 80 160 160 18.9 18.9 18.9 18.9 5.51 5.51 11.0 11.0 ) 275) 275) 720) 1100) 275 275 525 600 18.9 18.9 49.6 75.8 ) 18.9 18.9 ) 36.1 41.3 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style 12,14,15,16, 22,24,25,26 32,34,35,36,37 JOSJBS42,44,45,46,47 JLTJOS-H56,57 30 M Orifice Valve Dimensions - in. (mm) Approx. Center to Face Use To Approximate Height Weight Inlet Outlet Find Bolt lbs(kg) Length Valve (Cap) Type Type E F X J&L C D J 7 7-1/4 2-1/8 33-1/2 33 33-3/4 201 (178) (184) (54) (851) (838) (857) (91) 7 7-1/4 2-1/8 36 35-1/2 36 222 (178) (184) (54) (914) (902) (914) (101) 7 8 2-7/16 42 41 41-3/4 265 (178) (203) (62) (1067) (1041) (1060) (120) 7 3/4 8-3/4 2-9/16 42-3/4 41-3/4 42-1/2 290 (197) (222) (65) (1086) (1060) (1080) (132) Please refer to Warranty and Warnings on page 63. TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart M Orifice 3.60 sq. in. (2323 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 200 400 300 100 200 100 0 0 -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 31 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H N Orifice 4.34 sq. in. (2800 sq. mm) Effective Area ValveSize Inlet x Orifice x Outlet Valve Style Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) Inlet Inlet Outlet -450F -75F -20F to to to -76F -21F +100F 285) 285) 740) 1000) 15 25 35 45 4N6 4N6 4N6 4N6 150 300 300 600 150 150 150 150 JOSJBSJLTJOS-H- 16 26 36 46 4N6 4N6 4N6 4N6 150 300 300 600 150 150 150 150 JOSJBSJLTJOS-H- 37 47 4N6 4N6 300 600 150 150 JOSJBSJLT- 14 24 34 44 4N6 4N6 4N6 4N6 150 300 300 600 150 150 150 150 12 22 32 42 4N6 4N6 4N6 4N6 150 300 300 600 Back Press. Limit@100F psig Maximum Set Pressure - psig Standard Connections ANSIFlanges RaisedFace JOSJBSJLT*JOS-H- JOSJBSJLT- Low Set Pressure Limits: JOS = 8 psig (0.55 barg) JBS = 10 psig (0.68 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) 150 150 150 150 * +450F +800F +1000F JOS † JBS † 80 80 160 160 185 285 615 1000 ) 285 285 285 285 185 285 615 1000 80 285 410 825 285 285 285 285 80 80 160 160 285 285 160 160 275 275 275 275 80 80 160 160 510 1000 225 445 275) 275) 720) 1000) 275 275 450 500 275 275 275 275 80 80 160 160 Back Press. Limit@38C barg Maximum Set Pressure - barg Inlet -268C to -60C -59C to -30C -29C to +38C +232C 19.6 19.6 51.0 68.9 12.7 19.6 42.4 68.9 * +427C 12.7 19.6 42.4 68.9 5.51 19.6 28.2 56.8 35.1 68.9 18.9 18.9 49.6 68.9 +538C ) 18.9 18.9) 31.0 34.4 15.5 30.6 ) JOS † JBS † 19.6 19.6 19.6 19.6 5.51 5.51 11.0 11.0 19.6 19.6 19.6 19.6 5.51 5.51 11.0 11.0 19.6 19.6 11.0 11.0 18.9 18.9 18.9 18.9 5.51 5.51 11.0 11.0 18.9 18.9 18.9 18.9 5.51 5.51 11.0 11.0 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style JOS12,14,15,16, JBS22,24,25,26 JLT32,34,35,36,37 JOS-H42,44,45,46,47 32 N Orifice Valve Dimensions - in. (mm) Center to Face Use To Approximate Height Inlet Outlet Find Bolt Length Valve (Cap) Type E F X J&L C D 7-3/4 8-1/4 2-1/8 43-1/4 42-1/4 43 (197) (210) (54) (1099) (1073) (1092) 7-3/4 8-1/4 2-1/8 43-1/4 42-1/4 43 (197) (210) (54) (1099) (1073) (1092) 7-3/4 8-3/4 2-3/8 43-1/4 42-1/4 43 (197) (222) (60) (1099) (1073) (1092) Please refer to Warranty and Warnings on page 63. Approx. Weight lbs(kg) Type J 260 (118) 280 (127) 297 (135) TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart N Orifice 4.34 sq. in. (2800 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 33 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H P Orifice 6.38 sq. in. (4116 sq. mm) Effective Area ValveSize Inlet x Orifice x Outlet Valve Style Low Set Pressure Limits: JOS = 7 psig (0.48 barg) JBS = 8 psig (0.55 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) Standard Connections ANSIFlanges RaisedFace Inlet Outlet Maximum Set Pressure - psig -450F to -76F Inlet -75F -20F * to to +450F +800F +1000F -21F +100F Back Press. Limit@100F psig JOS † JBS † 80 80 150 150 JOSJBSJLT*JOS-H- 15 25 35 45 4P6 4P6 4P6 4P6 150 300 300 600 150 150 150 150 285) 185 285) 285 525) 525 1000) 1000 ) 285 285 285 285 JOSJBSJLTJOS-H- 16 26 36 46 4P6 4P6 4P6 4P6 150 300 300 600 150 150 150 150 185 285 525 1000 80 285 410 825 285 285 285 285 80 80 150 150 JOSJBSJLTJOS-H- 37 47 4P6 4P6 300 600 150 150 285 285 150 150 JOSJBSJLT- 14 24 34 44 4P6 4P6 4P6 4P6 150 300 300 600 150 150 150 150 275 275 275 275 80 80 150 150 JOSJBSJLT- 12 22 32 42 4P6 4P6 4P6 4P6 150 300 300 600 150 150 150 150 275 275 275 275 80 80 150 150 510 1000 225 445 275) 275) 525) 1000) 175 175 300 480 Maximum Set Pressure - barg -268C -59C to to -60C -30C Back Press. Limit@38C barg Inlet -29C * to +232C +427C +538C +38C JOS † JBS † 19.6 19.6 36.1 68.9 19.6 19.6 19.6 19.6 5.51 5.51 10.3 10.3 19.6 19.6 19.6 19.6 5.51 5.51 10.3 10.3 12.7 19.6 36.1 68.9 12.7 19.6 36.1 68.9 5.51 19.6 28.1 56.8 35.1 68.9 18.9 18.9 36.1 68.9 ) 12.0 ) 12.0 20.6 33.0 15.5 ) 30.6 19.6 10.3 19.6 10.3 18.9 18.9 18.9 18.9 5.51 5.51 10.3 10.3 18.9 18.9 18.9 18.9 5.51 5.51 10.3 10.3 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style JOS12,14,15,16, JBS22,24,25,26 JLT32,34,35,36,37 JOS-H42,44,45,46,47 34 P Orifice Valve Dimensions - in. (mm) Center to Face Use To Approximate Height Inlet Outlet Find Bolt Length Valve (Cap) Type E F X J&L C D 7-1/8 9 2-1/8 42-1/2 41-1/2 42-1/4 (181) (229) (54) (1080) (1054) (1073) 8-7/8 10 2-1/8 44-1/4 43-1/4 44 (225) (254) (54) (1124) (1099) (1118) 8-7/8 10 2-9/16 46-1/2 45-1/2 46-1/4 (225) (254) (65) (1181) (1156) (1175) Please refer to Warranty and Warnings on page 63. Approx. Weight lbs(kg) Type J 270 (122) 286 (130) 401 (182) TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart P Orifice 6.38 sq. in. (4116 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 35 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H Q Orifice 11.05 sq. in. (7129 sq. mm) Effective Area Valve Size Inlet x Orifice x Outlet Valve Style Low Set Pressure Limits: JOS = 5 psig (0.34 barg) JBS = 7 psig (0.48 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) Back Press. Maximum Set Pressure - psig Maximum Set Pressure - barg Standard Limit @100F Connections Inlet Inlet psig ANSI Flanges Raised Face -450F -75F -20F -268C -59C -29C * * to to to +232C +427C +538C to to to +450F +800F +1000F JOS JBS Inlet Outlet -76F -21F +100F -60C -30C +38C † † JOSJBSJLT*JOS-H- 15 25 35 45 6Q8 6Q8 6Q8 6Q8 150 300 300 600 150 150 150 150 JOSJBSJLTJOS-H- 16 26 36 46 6Q8 6Q8 6Q8 6Q8 150 300 300 600 150 150 150 150 JOSJBSJLTJOS-H- 37 47 6Q8 6Q8 300 600 150 150 JOSJBSJLT- 14 24 34 44 6Q8 6Q8 6Q8 6Q8 150 300 300 600 150 150 150 150 JOSJBSJLT- 12 22 32 42 6Q8 6Q8 6Q8 6Q8 150 300 300 600 150 150 150 150 165) 165) 300) 600) 165 165 300 600 ) 115 70) 115 70) 115 115) 115 115) 165 165 300 600 80 165 300 600 115 70) 115 70) 115 115) 115 115) 165 165 600 445 115 115 115 115 165) 165) 300) 600) 11.3 11.3 20.6 41.3 115 70 115 70 115 115 115 115 165 165 250 300 JOS † JBS † 7.92 7.92 7.92 7.92 4.82 4.82 7.92 7.92 5.51 11.3 20.6 41.3 7.92 7.92 7.92 7.92 4.82 4.82 7.92 7.92 11.3 41.3 11.3 7.92 30.6 ) 7.92 7.92 7.92 7.92 7.92 7.92 7.92 4.82 4.82 7.92 7.92 7.92 7.92 7.92 7.92 4.82 4.82 7.92 7.92 11.3 11.3 20.6 41.3 11.3 11.3 20.6 41.3 11.3 11.3 20.6 41.3 Back Press. Limit @38C barg ) 115 70 11.3 115 70 11.3) 115 115 17.2 115 115 20.6 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style JOS12,14,15,16, JBS22,24,25,26 JLT32,34,35,36,37 JOS-H42,44,45,46,47 36 Q Orifice Valve Dimensions - in. (mm) Center to Face Use To Approximate Height Inlet Outlet Find Bolt Length Valve (Cap) Type E F X J&L C D 9-7/16 (240) 9-7/16 (240) 9-7/16 (240) 9-1/2 (241) 9-1/2 (241) 9-1/2 (241) 2-5/16 (59) 2-5/16 (59) 2-15/16 (75) 47-3/4 (1213) 47-3/4 (1213) 51-3/4 (1314) Please refer to Warranty and Warnings on page 63. 46-3/4 (1187) 46-3/4 (1187) 50-3/4 (1289) 47-1/2 (1207) 47-1/2 (1207) 51-1/2 (1308) Approx. Weight lbs(kg) Type J 481 (218) 492 (223) 565 (256) TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart Q Orifice 11.05 sq. in. (7129 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 37 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H R Orifice 16.0 sq. in. (10323 sq. mm) Effective Area Low Set Pressure Limits: JOS = 8 psig (0.55 barg) JBS = 8 psig (0.55 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) Back Press. Valve Size Maximum Set Pressure - psig Maximum Set Pressure - barg Standard Limit @100F Connections Inlet Inlet Inlet psig ANSI Flanges x Raised Face -268C -59C -29C Orifice -450F -75F -20F * * to to to +232C +427C +538C x to to to +450F +800F +1000F JOS JBS Inlet Outlet -76F -21F +100F -60C -30C +38C Outlet † † Valve Style JOSJBSJLT*JOS-H- 15 25 35 45 6R8 6R8 6R10 6R10 150 300 300 600 150 150 150 150 JOSJBSJLTJOS-H- 16 26 36 46 6R8 6R8 6R10 6R10 150 300 300 600 150 150 150 150 JOSJBSJLTJOS-H- 37 47 6R8 6R10 300 600 150 150 JOSJBSJLT- 14 24 34 44 6R8 6R8 6R10 6R10 150 300 300 600 150 150 150 150 JOSJBSJLT- 12 22 32 42 6R8 6R8 6R10 6R10 150 300 300 600 150 150 150 150 100) 100) 230) 300) 100 100 230 300 100 100 230 300 ) 60 60 100 100 60 60 100 100 80 100 230 300 60 60 100 100 60 60 100 100 60 100 60 100 60 60 100 100 60 60 100 100 60 60 100 100 60 60 100 100 100 300 100 300 100) 100) 230) 300) 55 55 150 200 6.89 6.89 15.8 20.6 6.89 6.89 15.8 20.6 6.89 6.89 15.8 20.6 6.89 6.89 15.8 20.6 ) 3.79 3.79) 10.3 13.7 Back Press. Limit @38C barg JOS † JBS † 4.13 4.13 6.89 6.89 4.13 4.13 6.89 6.89 5.51 6.89 15.8 20.6 4.13 4.13 6.89 6.89 4.13 4.13 6.89 6.89 6.89 20.6 6.89 4.13 20.6) 6.89 4.13 6.89 4.13 4.13 6.89 6.89 4.13 4.13 6.89 6.89 4.13 4.13 6.89 6.89 4.13 4.13 6.89 6.89 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style JOS12,14,15,16, JBS22,24,25,26 JLT32,34,35,36,37 JOS-H42,44,45,46,47 38 R Orifice Valve Dimensions - in. (mm) Center to Face Use To Approximate Height Inlet Outlet Find Bolt Length Valve (Cap) Type E F X J&L C D 9-7/16 (240) 9-7/16 (240) 9-7/16 (240) 9-1/2 (241) 10-1/2 (267) 10-1/2 (267) 2-5/16 (59) 2-5/16 (59) 2-3/4 (70) 53-1/4 (1353) 53-1/4 (1353) 53-1/4 (1353) Please refer to Warranty and Warnings on page 63. 52-1/2 (1334) 52-1/2 (1334) 52-1/2 (1334) 53-1/4 (1353) 53-1/4 (1353) 53-1/4 (1353) Approx. Weight lbs(kg) Type J 564 (256) 602 (273) 631 (286) TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart R Orifice 16.0 sq. in. (10323 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 39 Specifications - Crosby Styles JOS, JBS, JLT and JOS-H T Orifice 26.0 sq. in. (16774 sq. mm) Effective Area Low Set Pressure Limits: JOS = 8 psig (0.55 barg) JBS = 8 psig (0.55 barg) JLT-JOS = 15 psig (1.03 barg) JLT-JBS = 25 psig (1.72 barg) Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) Back Press. Valve Size Maximum Set Pressure - psig Maximum Set Pressure - barg Standard Limit @100F Connections Inlet Inlet Inlet psig ANSI Flanges x Raised Face -450F -75F -20F -268C -59C -29C Orifice * * to to to +450F +800F +1000F JOS JBS to to to +232C +427C +538C x Inlet Outlet -76F -21F +100F † † -60C -30C +38C Outlet Valve Style JOSJBSJLT*JOS-H- 15 25 35 45 8T10 8T10 8T10 8T10 150 300 300 300 150 150 150 150 JOSJBSJLTJOS-H- 16 26 36 46 8T10 8T10 8T10 8T10 150 300 300 300 150 150 150 150 JOSJBSJLTJOS-H- 37 8T10 300 150 JOSJBSJLT- 14 24 34 8T10 8T10 8T10 150 300 300 150 150 150 JOSJBSJLT- 12 22 32 8T10 8T10 8T10 150 300 300 150 150 150 65) 65) 120) 300) 65 65 120 300 ) 30 30 30 30 60 60 100 100 65 65 120 300 65 65 120 300 30 30 30 30 60 60 100 100 300 225 65) 65) 120) 50 50 65 60 60 30 30 60 30 30 60 30 30 60 30 3.44 30 3.44 ) 60 4.48 4.48 4.48 8.27 20.6 4.48 4.48 8.27 20.6 4.48 4.48 8.27 20.6 4.48 4.48 8.27 20.6 20.6 4.48 4.48 8.27 15.5 Back Press. Limit @38C barg JOS † JBS † 2.06 2.06 4.13 6.89 2.06 2.06 4.13 6.89 2.06 2.06 4.13 6.89 2.06 2.06 4.13 6.89 4.13 4.13 2.06 2.06 4.13 2.06 2.06 4.13 2.06 2.06 4.13 2.06 2.06 4.13 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style JOS12,14,15,16, JBS22,24,25,26 JLT32,34,35,36,37 JOS-H45,46 40 T Orifice Valve Dimensions - in. (mm) Approx. Center to Face Use To Approximate Height Weight Inlet Outlet Find Bolt lbs(kg) Length Valve (Cap) Type Type E F X J&L C D J 10-7/8 11 2-9/16 59-1/2 58-1/2 59-1/4 882 (276) (279) (65) (1511) (1486) (1505) (400) 10-7/8 11 2-9/16 59-1/2 58-1/2 59-1/4 902 (276) (279) (65) (1511) (1486) (1505) (409) 10-7/8 11 2-9/16 59-1/2 58-1/2 59-1/4 930 (276) (279) (65) (1511) (1486) (1505) (422) Please refer to Warranty and Warnings on page 63. TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart T Orifice 26.0 sq. in. (16774 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 41 Specifications - Crosby Styles JOS, JBS and JOS-H T2 Orifice 27.872 sq. in. (17981 sq. mm) Effective Area Low Set Pressure Limits: JOS = 8 psig (0.55 barg) JBS = 8 psig (0.55 barg) Sizes and Pressure/Temperature Limits (See also Set Pressure Chart Opposite) Back Press. Valve Size Maximum Set Pressure - psig Maximum Set Pressure - barg Standard Limit @100F Connections Inlet Inlet Inlet psig ANSI Flanges x Raised Face -450F -75F -20F -268C -59C -29C Orifice * * to to to +450F +800F +1000F JOS JBS to to to +232C +427C +538C x Inlet Outlet -76F -21F +100F † † -60C -30C +38C Outlet Valve Style JOS15 JBS25 *JOS-H- 35 45 8T210 8T210 8T210 8T210 150 300 300 300 150 150 150 150 JOSJBSJOS-H- 16 26 36 46 8T210 8T210 8T210 8T210 150 300 300 300 150 150 150 150 JOSJBSJOS-H- 37 8T210 300 150 JOSJBS- 14 24 34 8T210 8T210 8T210 150 300 300 150 150 150 JOSJBS- 12 22 32 8T210 8T210 8T210 150 300 300 150 150 150 65) 65) 120) 300) 65 65 120 300 ) 30 30 30 30 60 60 100 100 65 65 120 300 65 65 120 300 30 30 30 30 60 60 100 100 300 225 65) 65) 120) 50 50 65 60 60 30 30 60 30 30 60 30 30 60 30 30 60 4.48 4.48 8.27 20.6 4.48 4.48 8.27 20.6 4.48 4.48 8.27 20.6 4.48 4.48 8.27 20.6 20.6 4.48 4.48 8.27 3.44 3.44 ) 4.48 15.5 Back Press. Limit @38C barg JOS † JBS † 2.06 2.06 4.13 6.89 2.06 2.06 4.13 6.89 2.06 2.06 4.13 6.89 2.06 2.06 4.13 6.89 4.13 4.13 2.06 2.06 4.13 2.06 2.06 4.13 2.06 2.06 4.13 2.06 2.06 4.13 *Upper temperature limit of JOS-H-15, 25, 35 and 45 valves is +650F (+343C). †Outlet pressure for temperatures above +100F (+38C) should not exceed the ANSI flange rating. Valves set below 15 psig (1.03 barg) cannot be stamped with the ASME Code Symbol. Only metal seated valves may be set below 15 psig. Dimensions and Weights Valve Style JOS12,14,15,16, JBS22,24,25,26 JOS-H- 32,34,35,36,37 45,46 42 T2 Orifice Valve Dimensions - in. (mm) Approx. Center to Face Use To Approximate Height Weight Inlet Outlet Find Bolt lbs(kg) Length Valve (Cap) Type Type E F X J&L C D J 10-7/8 11 2-9/16 59-1/2 58-1/2 59-1/4 882 (276) (279) (65) (1511) (1486) (1505) (400) 10-7/8 11 2-9/16 59-1/2 58-1/2 59-1/4 902 (276) (279) (65) (1511) (1486) (1505) (409) 10-7/8 11 2-9/16 59-1/2 58-1/2 59-1/4 930 (276) (279) (65) (1511) (1486) (1505) (422) Please refer to Warranty and Warnings on page 63. TYPE J (SCREWED CAP) TYPE C (REGULAR LIFTING LEVER) (also JOS-H) TYPE D (PACKED LIFTING LEVER) TYPE L (BOLTED CAP) Pressure-Temperature Limit Chart T2 Orifice 27.872 sq. in. (17981 sq.mm) Effective Area SET PRESSURE - barg 1000 500 900 800 400 700 600 300 500 400 200 300 100 200 100 0 0 -100 -100 -200 -300 -200 -400 -450 SET PRESSURE - psig Please refer to Warranty and Warnings on page 63. 43 Air Capacities Styles JOS and JBS Capacity in standard cubic feet per minute of air at 60F and 10% overpressure.† Valve discharging to atmospheric pressure. Set Pressures USCS UNITS 5-780 psig (United States Customary System) Shaded values are JOS only Note: For air capacities, USCS Units are exact equivalents of Imperial Units. Set Pressure (psig) *1 psi incr. *5 psi incr. D 0.110 2.1 10.8 5 6 7 8 9 E 0.196 3.8 19.2 F 0.307 6.0 30.2 G 0.503 9.8 49.4 H 0.785 15.4 77.2 ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq. in. J K L M N P 1.287 1.838 2.853 3.60 4.34 6.38 25.3 36.1 56.1 70.8 85.3 125 126 180 280 354 426 627 89.9 93.6 121 128 135 140 146 199 211 221 230 240 311 329 345 360 374 510 540 566 590 614 728 771 808 843 877 1197 1255 1308 1362 1651 1719 1991 2072 Q 11.05 217 1087 R T T2 16.0 26.0 27.872 314 511 548 1574 2557 2742 2807 2927 3047 4379 4637 4862 5069 5277 7340 7641 11928 12417 12787 13312 10 15 20 30 40 54.5 64.3 74.1 93.8 115 97.1 114 132 167 205 152 179 207 261 322 249 294 339 429 528 388 459 529 669 824 637 752 867 1098 1351 910 1075 1239 1568 1929 1413 1668 1924 2434 2995 1783 2105 2427 3071 3780 2150 2538 2926 3703 4557 3161 3731 4302 5443 6699 5475 6463 7451 9428 11602 7928 9359 10790 13652 16800 12883 15208 17533 22184 27300 13810 16303 18796 23782 29266 50 60 70 80 90 137 158 180 202 223 244 282 321 360 398 382 443 503 563 624 627 726 825 924 1023 978 1133 1287 1442 1596 1604 1857 2111 2364 2617 2291 2653 3014 3376 3738 3557 4118 4679 5241 5802 4488 5196 5905 6613 7321 5411 6265 7119 7973 8827 7954 9209 10465 11720 12976 13777 15951 18125 20300 22474 19948 23097 26245 29393 32542 32416 37532 42648 47764 52880 34750 40235 45719 51203 56688 100 120 140 160 180 245 288 331 375 418 437 514 591 668 745 684 805 926 1047 1168 1122 1319 1517 1715 1913 1751 2059 2368 2677 2986 2870 3377 3883 4390 4896 4099 4823 5546 6269 6993 6364 7486 8609 9732 10855 8030 9447 10863 12280 13697 9680 11388 13096 14804 16512 14231 16742 19253 21763 24274 24648 28997 33345 37694 42043 35690 41986 48283 54580 60876 57996 62172 68228 73141 78460 84109 88692 95078 98924 106047 200 220 240 260 280 461 505 548 591 634 822 900 977 1054 1131 1288 1409 1530 1651 1772 2111 2309 2507 2705 2903 3295 3604 3913 4222 4531 5403 5909 6416 6922 7429 7716 8439 9163 9886 10609 11977 13100 14223 15346 16468 15114 16530 17947 19364 20780 18220 19928 21636 23344 25052 26785 29296 31806 34317 36828 46391 50740 55088 59437 63785 67173 73469 79766 86063 92359 300 320 340 360 380 678 721 764 808 851 1208 1285 1362 1439 1517 1892 2013 2134 2255 2376 3101 3299 3497 3695 3893 4840 5149 5458 5767 6076 7935 8442 8948 9455 9961 11333 12056 12779 13503 14226 17591 18714 19837 20959 22082 22197 23614 25031 26447 27864 26760 28468 30176 31884 33592 39339 41850 44360 46871 49382 68134 72483 76831 81180 85528 98656 160316 171859 400 420 440 460 480 894 937 981 1024 1067 1594 1671 1748 1825 1902 2497 2617 2738 2859 2980 4091 4289 4487 4685 4883 6384 6693 7002 7311 7620 10468 10974 11481 11987 12494 14949 15673 16396 17119 17843 23205 24328 25451 26573 27696 29281 30698 32114 33531 34948 35300 37008 38716 40424 42132 51893 54403 56914 59425 61936 89877 94226 98574 102923 107271 500 520 540 560 580 1111 1154 1197 1241 1284 1979 2057 2134 2211 2288 3101 3221 3342 3463 3584 5081 5278 5476 5674 5872 7929 8238 8547 8856 9165 13000 13506 14013 14519 15026 18566 19289 20013 20736 21459 28819 29942 31064 32187 33310 36365 37781 39198 40615 42032 43840 45548 47256 48963 50671 64446 66957 69468 71979 74490 111620 115969 120317 124666 129014 600 620 640 660 680 1327 1370 1414 1457 1500 2365 2442 2519 2596 2674 3705 3826 3946 4067 4188 6070 6268 6466 6664 6862 9474 9783 10092 10401 10709 15532 16039 16545 17052 17558 22182 22906 23629 24352 25076 34433 35555 36678 37801 38924 43448 44865 46282 47698 49115 52379 54087 55795 57503 59211 77000 79511 82022 84533 87043 133363 700 720 740 760 780 1544 1587 1630 1673 1717 2751 2828 2905 2982 3059 4309 4430 4550 4671 4792 7060 7258 7456 7654 7852 11018 11327 11636 11945 12254 18065 18571 19078 19584 20091 25799 26522 27246 27969 28692 40046 41169 42292 43415 44538 50532 51949 53365 54782 56199 60919 62627 64335 66043 67751 89554 92065 94576 97087 99597 *Not valid below 30 psig set pressure. †Capacities below 30 psig set pressure are calculated at 3 psi overpressure. 44 Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. Please refer to Warranty and Warnings on page 63. 109156 119388 129620 139852 150084 117015 127984 138953 149922 160890 Air Capacities Styles JOS and JBS Set Pressures 800-6000 psig Capacity in standard cubic feet per minute of air at 60F and 10% overpressure. Valve discharging to atmospheric pressure. USCS UNITS (United States Customary System) Note: For air capacities, USCS Units are exact equivalents of Imperial Units. Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. Set Pressure (psig) 1 psi incr. 5 psi incr. D 0.110 2.1 10.8 800 820 840 860 880 1760 1803 1847 1890 1933 3136 3214 3291 3368 3445 4913 5034 5155 5275 5396 8050 8248 8446 8644 8842 12563 12872 13181 13490 13799 20597 21104 21610 22117 22623 29416 30139 30862 31586 32309 45660 46783 47906 49029 50151 57616 59032 60449 61866 63283 69459 71167 72875 74583 76291 102108 104619 107130 109640 112151 900 920 940 960 980 1976 2020 2063 2106 2150 3522 3599 3676 3753 3831 5517 5638 5759 5879 6000 9039 9237 9435 9633 9831 14108 14417 14726 15034 15343 23130 23636 24143 24649 25156 33032 33756 34479 35202 35926 51274 52397 53520 54642 55765 64699 66116 67533 68950 70366 77999 79707 81415 83123 84831 114662 117173 119683 122194 124705 1000 1100 1200 1300 1400 2193 2409 2626 2842 3059 3908 4293 4679 5065 5450 6121 6725 7329 7933 8537 10029 11019 12009 12998 13988 15652 17197 18742 20286 21831 25662 28195 30727 33259 35792 36649 40266 43882 47499 51115 56888 62502 68116 73729 79343 71783 78867 86538 127216 1480 1500 1600 1700 1800 3232 3275 3492 3708 3924 5759 9021 5836 9141 6222 9746 6607 10350 6993 10954 14780 14978 15968 16957 17947 23067 23375 24920 26465 28009 37818 38324 40857 43389 45921 54009 54732 58349 61965 65582 83834 1900 2000 2100 2200 2300 4141 4357 4574 4790 5007 7379 7764 8150 8536 8921 11558 12162 12766 13370 13974 18937 19927 20916 21906 22896 29554 31099 32643 34188 35733 48454 50986 53519 56051 58584 69198 72815 76432 80048 2400 2500 2600 2700 2800 5223 9307 14578 5440 9693 15182 5656 10078 15786 5872 10464 16390 6089 10850 16994 23886 24875 25865 26855 27845 37277 38822 40366 41911 61116 63648 66181 68713 2900 3000 3100 3200 3300 6305 6522 6738 6955 7171 11235 11621 12007 12392 12778 17599 18203 18807 19411 20015 28834 29824 30814 31804 32793 3400 3500 3600 3700 3800 7388 7604 7820 8037 8253 13164 13549 13935 14321 14706 20619 21223 21827 22431 23035 33783 34773 35763 36752 3900 4000 4200 4400 4600 8470 8686 9119 9552 9985 15092 15478 16249 17020 17792 23639 24243 25452 26660 27868 4800 5000 5200 5400 5600 5800 6000 10418 10851 11284 11717 12149 12582 13015 E 0.196 3.8 19.2 F 0.307 6.0 30.2 G 0.503 9.8 49.4 H 0.785 15.4 77.2 ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq. in. J K L M N P 1.287 1.838 2.853 3.60 4.34 6.38 25.3 36.1 56.1 70.8 85.3 125 126 180 280 354 426 627 Q 11.05 217 1087 R T T2 16.0 26.0 27.872 314 511 548 1574 2557 2742 18563 29076 19334 30284 20106 20877 21648 22420 23191 Please refer to Warranty and Warnings on page 63. 45 Water Capacities Styles JLT-JOS and JLT-JBS Differential Pressures 5-1040 psi† Capacity in U.S. gallons per minute of water at 70F and 10% overpressure. P* USCS UNITS Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. (United States Customary System) Note: USCS Units for water and liquids are U.S. gallons per minute (1 U.S. gallon equals 0.8327 Imperial gallon). Diff.* Pressure P (psi) D 0.110 E 0.196 F 0.307 G 0.503 H 0.785 5 10 15 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720 740 760 780 800 820 840 860 880 900 920 940 960 980 1000 1020 1040 6.9 9.7 11.9 13.8 19.5 23.9 27.6 30.9 33.9 36.6 39.1 41.5 43.7 45.9 47.9 49.9 51.7 53.6 55.3 57.0 58.7 60.3 61.9 63.4 64.9 66.3 67.8 69.2 70.5 71.9 73.2 74.5 75.8 77.0 78.3 79.5 80.7 81.8 83.0 84.2 85.3 86.4 87.5 88.6 89.7 90.7 91.8 92.8 93.8 94.9 95.9 96.9 97.8 98.8 99.8 12.3 17.4 21.3 24.6 34.8 42.7 49.3 55.1 60.4 65.2 69.7 73.9 78.0 81.8 85.4 88.9 92.2 95.5 98.6 101 104 107 110 113 115 118 120 123 125 128 130 132 135 137 139 141 143 145 147 150 152 154 156 157 159 161 163 165 167 169 170 172 174 176 177 19.3 27.3 33.4 38.6 54.6 66.9 77.2 86.3 94.6 102 109 115 122 128 133 139 144 149 154 159 163 168 172 177 181 185 189 193 196 200 204 208 211 215 218 221 225 228 231 235 238 241 244 247 250 253 256 259 262 264 267 270 273 275 278 31.6 44.7 54.8 63.3 89.5 109 126 141 155 167 179 189 200 209 219 228 236 245 253 260 268 275 283 290 296 303 310 316 322 328 334 340 346 352 358 363 369 374 379 385 390 395 400 405 410 415 419 424 429 433 438 443 447 452 456 49.3 69.8 85.5 98.7 139 171 197 220 241 261 279 296 312 327 342 356 369 382 395 407 419 430 441 452 463 473 483 493 503 513 522 531 541 550 558 567 576 584 592 600 608 616 624 632 640 647 655 662 670 677 684 691 698 705 712 ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq. in. J K L M N P 1.287 1.838 2.853 3.60 4.34 6.38 80.9 114 140 161 229 280 323 362 396 428 458 485 512 537 561 583 606 627 647 667 687 705 724 742 759 776 793 809 825 841 857 872 887 901 916 930 944 958 971 985 998 1011 1024 1037 1049 1062 1074 1086 1098 1110 1122 1133 1145 1156 1167 115 163 200 231 327 400 462 517 566 611 654 693 731 767 801 833 865 895 925 953 981 1008 1034 1059 1084 1109 1133 1156 1179 1201 1223 1245 1266 1287 1308 1328 1348 1368 1387 1406 1425 1444 1462 1481 1499 1516 1534 1551 1568 1585 1602 1619 1635 1651 1667 179 253 310 359 507 621 718 802 879 949 1015 1077 1135 1190 1243 1294 1343 1390 1436 1480 1523 1565 1605 1645 1684 1721 1758 1795 1830 1865 1899 1933 1966 1999 2031 2062 2093 2124 2154 2183 2213 2242 2270 2298 2326 2354 2381 2408 2435 2461 2487 2513 2538 2564 2589 226 320 392 453 640 784 906 1013 1109 1198 1281 1359 1432 1502 1569 1633 1695 1754 1812 1867 1922 1974 2026 2076 2124 2172 2219 2265 2310 2354 2397 2439 2481 2522 2562 2602 2641 2680 2718 2755 2792 2829 2865 2900 2936 2970 3005 3039 3072 3105 3138 3171 3203 3235 3266 273 386 472 546 772 945 1092 1221 1337 1445 1544 1638 1727 1811 1891 1969 2043 2115 2184 2251 2317 2380 2442 2502 2561 2619 2675 2730 2784 2837 2890 2941 2991 3040 3089 3137 3184 3231 3277 3322 3366 3410 3454 3497 3539 3581 3622 3663 3704 3744 3783 3823 3862 3900 3938 401 567 695 802 1135 1390 1605 1795 1966 2124 2270 2408 2538 2662 2781 2894 3004 3109 3211 3310 3406 3499 3590 3679 3765 3850 3933 4014 4093 4171 4248 4323 4397 4470 4541 4612 4681 4750 4817 4883 4949 5014 5077 5141 5203 5264 5325 5385 5445 5504 5562 5620 5677 5733 5789 Q 11.05 R 16.0 T 26.0 695 983 1204 1390 1966 2408 2781 3109 3406 3679 3933 4171 4397 4612 4817 5013 5203 5385 5562 5733 5899 6061 6218 6372 6522 6669 6812 6952 7090 7225 7358 7488 7616 7742 7866 7988 1006 1423 1743 2013 2847 3487 4027 4502 4932 5327 5695 6040 6367 6678 6975 7259 7533 7798 8054 1635 2313 2833 3271 4627 5667 6543 7316 8014 8656 9254 9815 10346 10851 11334 11797 12242 12672 13087 P) equals) inlet pressure (set pressure plus overpressure) at flowing conditions minus back pressure. †See pages 14 to 43 for Minimum and Maximum Set Pressure Limits. *Differential Pressure ( 46 Please refer to Warranty and Warnings on page 63. Water Capacities Styles JLT-JOS and JLT-JBS Differential Pressures 1060-6600 psi† Capacity in U.S. gallons per minute of water at 70F and 10% overpressure. P* USCS UNITS Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. (United States Customary System) Note: USCS Units for water and liquids are U.S. gallons per minute (1 U.S. gallon equals 0.8327 Imperial gallon). Diff.* Pressure P (psi) 1060 1080 1100 1120 1140 1160 1180 1200 1220 1240 1260 1280 1300 1320 1340 1360 1380 1400 1420 1440 1460 1480 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 4600 4700 4800 4900 5000 5500 6000 6600 D 0.110 E 0.196 F 0.307 G 0.503 100 101 102 103 104 105 106 107 108 109 109 110 111 112 113 114 114 115 116 117 118 119 119 123 127 131 134 138 141 145 148 151 154 157 160 163 166 169 172 175 177 180 183 185 188 190 193 195 198 200 202 205 207 209 212 214 216 218 229 239 251 179 181 182 184 186 187 189 191 192 194 195 197 198 200 201 203 204 206 207 209 210 212 213 220 227 234 240 246 252 258 264 270 275 281 286 291 297 302 307 312 316 321 326 330 335 339 344 348 353 357 361 365 369 374 378 382 386 390 409 427 448 281 283 286 289 291 294 296 299 301 304 306 309 311 313 316 318 320 323 325 327 330 332 334 345 356 366 376 386 395 405 414 423 431 440 448 457 465 473 480 488 496 503 511 518 525 532 539 546 553 559 566 573 579 585 592 598 604 610 640 460 465 469 473 477 482 486 490 494 498 502 506 510 514 518 521 525 529 533 537 540 544 548 566 583 600 616 633 648 663 678 693 707 721 735 748 762 775 788 800 813 825 837 849 860 872 883 895 ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq. in. H J K L M N 0.785 1.287 1.838 2.853 3.60 4.34 719 725 732 739 745 752 758 765 771 777 784 790 796 802 808 814 820 826 832 838 844 849 855 883 910 937 962 987 1012 1036 1059 1082 1104 1126 1147 1168 1189 1209 1179 1190 1201 1212 1222 1233 1244 1254 1264 1275 1285 1295 1305 1315 1325 1335 1345 1355 1364 1374 1383 1393 1402 1448 1493 1536 1578 1619 1659 1698 1736 1774 1810 1846 1881 1916 1950 1983 1683 1699 1715 1730 1746 1761 1776 1791 1806 1821 1835 1850 1864 1879 1893 1907 1921 1935 1949 1962 1976 1989 2003 2068 2132 2194 2254 2313 2370 2425 2480 2533 2613 2638 2662 2686 2710 2734 2757 2781 2804 2827 2849 2872 2894 2916 2938 2960 2982 3003 3025 3046 3067 3088 3109 3211 3298 3329 3359 3390 3420 3450 3479 3509 3976 4013 4050 P 6.38 Q 11.05 R 16.0 T 26.0 5845 5900 5954 * Differential Pressure ( P) equals inlet pressure (set pressure plus overpressure) at flowing conditions minus back pressure. †See pages 14 to 43 for Minimum and Maximum Set Pressure Limits. Please refer to Warranty and Warnings on page 63. 47 Saturated Steam Capacities Unfired Pressure Vessel Service Styles JOS and JBS Set Pressures 5-550 psig USCS UNITS (United States Customary System) Shaded values are JOS only Set Pressure D (psig) 0.110 *1 psi incr. 6.0 *5 psi incr. 30.3 5 6 7 8 9 10 152 15 180 20 208 30 263 40 324 50 384 60 445 70 506 80 567 90 628 100 688 110 749 120 810 130 871 140 931 150 992 160 1053 170 1114 180 1174 190 1235 200 1296 210 1357 220 1417 230 1478 240 1539 250 1600 260 1660 270 1721 280 1782 290 1843 300 1903 310 1964 320 2025 330 2086 340 2146 350 2207 360 2268 370 2329 380 2389 390 2450 400 2511 410 2572 420 2632 430 2693 440 2754 450 2815 460 2876 470 2936 480 2997 490 3058 500 3119 510 3179 520 3240 530 3301 540 3362 550 3422 E 0.196 10.8 54.1 252 262 272 321 371 469 577 685 794 902 1010 1118 1227 1335 1443 1552 1660 1768 1876 1985 2093 2201 2309 2418 2526 2634 2742 2851 2959 3067 3175 3284 3392 3500 3608 3717 3825 3933 4041 4150 4258 4366 4474 4583 4691 4799 4908 5016 5124 5232 5341 5449 5557 5665 5774 5882 5990 6098 F 0.307 16.9 84.7 341 361 379 395 411 427 504 581 735 904 1074 1244 1413 1583 1752 1922 2091 2261 2430 2600 2770 2939 3109 3278 3448 3617 3787 3957 4126 4296 4465 4635 4804 4974 5144 5313 5483 5652 5822 5991 6161 6331 6500 6670 6839 7009 7178 7348 7518 7687 7857 8026 8196 8365 8535 8704 8874 9044 9213 9383 9552 G 0.503 27.7 138 559 592 621 647 674 699 825 952 1204 1482 1760 2038 2316 2593 2871 3149 3427 3705 3983 4260 4538 4816 5094 5372 5649 5927 6205 6483 6761 7039 7316 7594 7872 8150 8428 8706 8983 9261 9539 9817 10095 10373 10650 10928 11206 11484 11762 12039 12317 12595 12873 13151 13429 13706 13984 14262 14540 14818 15096 15373 15651 Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq. in. H J K L M N P 0.785 1.287 1.838 2.853 3.60 4.34 6.38 43.3 71.0 101 157 198 239 352 216 355 507 787 994 1198 1761 873 1431 2044 924 1516 2165 3361 969 1589 2270 3524 7881 1010 1657 2367 3674 4636 5589 8216 1052 1725 2464 3824 4826 5818 8553 1091 1790 2556 3968 5007 6036 8873 1288 2113 3017 4684 5911 7126 10475 1486 2436 3479 5400 6814 8215 12077 1880 3082 4402 6833 8622 10394 15280 2313 3793 5417 8409 10610 12792 18804 2747 4504 6432 9984 12599 15189 22328 3180 5215 7447 11560 14587 17586 25852 3614 5925 8463 13136 16576 19983 29376 4048 6636 9478 14712 18564 22380 32900 4481 7347 10493 16288 20552 24777 36424 4915 8058 11508 17864 22541 27174 39948 5348 8769 12523 19439 24529 29572 43472 5782 9480 13539 21015 26518 31969 46996 6216 10191 14554 22591 28506 34366 50520 6649 10901 15569 24167 30495 36763 54044 7083 11612 16584 25743 32483 39160 57567 7516 12323 17599 27318 34471 41557 61091 7950 13034 18615 28894 36460 43954 64615 8383 13745 19630 30470 38448 46352 68139 8817 14456 20645 32046 40437 48749 71663 9251 15167 21660 33622 42425 51146 75187 9684 15877 22675 35198 44413 53543 78711 10118 16588 23690 36773 46402 55940 82235 10551 17299 24706 38349 48390 58337 85759 10985 18010 25721 39925 50379 60734 89283 11419 18721 26736 41501 52367 63132 92807 11852 19432 27751 43077 54356 65529 96330 12286 20143 28766 44652 56344 67926 99854 12719 20853 29782 46228 58332 70323 103378 13153 21564 30797 47804 60321 72720 106902 13586 22275 31812 49380 62309 75117 110426 14020 22986 32827 50956 64298 77514 113950 14454 23697 33842 52532 66286 79912 117474 14887 24408 34858 54107 68274 82309 120998 15321 25119 35873 55683 70263 84706 124522 15754 25830 36888 57259 72251 87103 128046 16188 26540 37903 58835 74240 89500 131570 16622 27251 38918 60411 76228 91897 135094 17055 27962 39934 61986 78217 94294 138617 17489 28673 40949 63562 80205 96692 142141 17922 29384 41964 65138 82193 99089 145665 18356 30095 42979 66714 84182 101486 149189 18789 30806 43994 68290 86170 103883 152713 19223 31516 45010 69866 88159 106280 156237 19657 32227 46025 71441 90147 108677 159761 20090 32938 47040 73017 92135 111074 163285 20524 33649 48055 74593 94124 113472 166809 20957 34360 49070 76169 96112 115869 170333 21391 35071 50086 77745 98101 118266 173857 21825 35782 51101 79320 100089 120663 177380 22258 36492 52116 80896 102077 123060 180904 22692 37203 53131 82472 104066 125457 184428 23125 37914 54146 84048 106054 127854 187952 23559 38625 55162 85624 108043 130252 191476 23993 39336 56177 87200 110031 132649 195000 24426 40047 57192 88775 112020 135046 198524 †Capacities below 30 psig set pressure are calculated at 3 psig overpressure. *Not valid below 30 psig set pressure. 48 Capacity in pounds per hour of steam at 10% overpressure.† Valve discharging to atmospheric pressure. Please refer to Warranty and Warnings on page 63. Q 11.05 610 3051 12292 13018 13649 14231 14814 15369 18143 20917 26466 32569 38672 44776 50879 56982 63086 69189 75292 81396 87499 93602 99706 105809 111912 118016 124119 130222 136326 142429 148532 154636 160739 166842 172946 179049 185152 191256 197359 203462 209566 215669 221772 227876 233979 240082 246186 252289 258392 264496 270599 276702 282806 288909 295012 301116 307219 313322 319426 325529 331632 337736 343839 R 16.0 883 4418 T 26.0 1436 7180 T2 27.872 1539 7697 20606 21450 22254 26271 30288 38322 47159 55996 64834 73671 82509 91346 100183 109021 117858 126696 135533 144370 153208 162045 170883 179720 188557 197395 206232 215070 223907 232744 241582 250419 259257 268094 276931 33484 34857 36163 42690 49218 62273 76634 90995 105355 119716 134077 148438 162798 177159 191520 205881 220242 234602 248963 263324 277685 292045 306406 320767 335128 349489 363849 378210 392571 406932 421292 435653 450014 35895 37367 38766 45764 52762 66757 82151 97546 112941 128336 143730 159125 174520 189915 205309 220704 236099 251494 266888 282283 297678 313073 328468 343862 359257 374652 390047 405441 420836 436231 451626 467020 482415 Saturated Steam Capacities Unfired Pressure Vessel Service Styles JOS and JBS Set Pressures 560-1700 psig Set Pressure (psig) 1 psi incr. 5 psi incr. 560 570 580 590 600 620 640 660 680 700 720 740 760 780 800 820 840 860 880 900 920 940 960 980 1000 1020 1040 1060 1080 1100 1120 1140 1160 1180 1200 1220 1240 1260 1280 1300 1320 1340 1360 1380 1400 1420 1440 1460 1480 1500 1520 1540 1560 1580 1600 1620 1640 1660 1680 1700 D 0.110 6.0 30.3 3483 3544 3605 3665 3726 3848 3969 4091 4212 4334 4455 4577 4698 4820 4941 5063 5184 5306 5427 5549 5670 5792 5913 6035 6156 6278 6399 6521 6642 6764 6885 7007 7129 7250 7372 7493 7615 7736 7858 7979 8101 8222 8312 8443 8575 8706 8839 8971 9105 9238 9373 9507 9642 9778 9914 10051 10188 10326 10465 10604 E 0.196 10.8 54.1 6207 6315 6423 6531 6640 6856 7073 7289 7506 7722 7939 8155 8372 8588 8805 9021 9238 9454 9671 9887 10104 10320 10537 10753 10970 11187 11403 11620 11836 12053 12269 12486 12702 12919 13135 13352 13568 13785 14001 14218 14434 14651 14811 15045 15279 15514 15749 15986 16223 16461 16700 16940 17181 17423 17666 17909 18154 18400 18647 18895 USCS UNITS (United States Customary System) F 0.307 16.9 84.7 9722 9891 10061 10231 10400 10739 11078 11418 11757 12096 12435 12774 13113 13452 13792 14131 14470 14809 15148 15487 15826 16165 16505 16844 17183 17522 17861 18200 18539 18879 19218 19557 19896 20235 20574 20913 21252 21592 21931 22270 22609 22948 23200 23565 23932 24300 24669 25039 25411 25784 26159 26535 26912 27290 27671 28052 28436 28821 29207 29595 ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq. in. G H J K L M N 0.503 0.785 1.287 1.838 2.853 3.60 4.34 27.7 43.3 71.0 101 157 198 239 138 216 355 507 787 994 1198 15929 24860 40758 58207 90351 114008 137443 16207 25293 41468 59222 91927 115996 139840 16485 25727 42179 60238 93503 117985 142237 16762 26160 42890 61253 95079 119973 144634 17040 26594 43601 62268 96655 121962 147032 17596 27461 45023 64298 99806 125938 151826 18152 28328 46444 66329 102958 129915 156620 18707 29196 47866 68359 106109 133892 161415 19263 30063 49288 70390 109261 137869 166209 19819 30930 50710 72420 112413 141846 171003 20374 31797 52131 74450 115564 145823 175797 20930 32664 53553 76481 118716 149799 180592 21486 33531 54975 78511 121868 153776 185386 22041 34399 56396 80541 125019 157753 190180 22597 35266 57818 82572 128171 161730 194975 23152 36133 59240 84602 131323 165707 199769 23708 37000 60662 86633 134474 169684 204563 24264 37867 62083 88663 137626 173660 209357 24819 38734 63505 90693 140777 177637 214152 25375 39602 64927 92724 143929 181614 218946 25931 40469 66348 94754 147081 185591 223740 26486 41336 67770 96785 150232 189568 228535 27042 42203 69192 98815 153384 193545 233329 27598 43070 70614 100845 156536 197521 238123 28153 43937 72035 102876 159687 201498 242917 28709 44805 73457 104906 162839 205475 29265 45672 74879 106937 165991 209452 29820 46539 76300 108967 169142 213429 30376 47406 77722 110997 172294 217406 30932 48273 79144 113028 175445 221382 31487 49140 80566 115058 178597 32043 50008 81987 117089 181749 32599 50875 83409 119119 184900 33154 51742 84831 121149 188052 33710 52609 86252 123180 191204 34266 53476 87674 125210 194355 34821 54343 89096 127241 197507 35377 55211 90518 129271 200659 35932 56078 91939 131301 203810 36488 56945 93361 133332 206962 37044 57812 94783 135362 210113 37599 58679 96204 137392 213265 38012 59323 97259 138899 215603 38610 60257 98791 141087 219000 39211 61195 100329 143282 222408 39814 62136 101871 145485 225827 40419 63080 103419 147695 229257 41026 64027 104972 149913 232700 41635 64977 106530 152139 236155 42246 65931 108094 154372 239622 42860 66889 109664 156614 43475 67850 111239 158864 44094 68814 112821 161123 44714 69783 114408 163390 45337 70755 116002 165666 45962 71731 117602 167951 46590 72711 119209 170246 47221 73695 120823 172550 47854 74683 122443 174864 48490 75676 124070 177189 Capacity in pounds per hour of steam at 10% overpressure. Valve discharging to atmospheric pressure. Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. P 6.38 352 1761 202048 205572 209096 212620 216144 223191 230239 237287 244335 251383 258430 265478 272526 279574 286622 293670 300717 307765 314813 321861 328909 335957 343004 350052 357100 Q 11.05 610 3051 349942 356046 362149 368252 374356 R 16.0 883 4418 Please refer to Warranty and Warnings on page 63. T 26.0 1436 7180 T2 27.872 1539 7697 49 Saturated Steam Capacities Unfired Pressure Vessel Service Styles JOS and JBS Set Pressures 1720-2900 psig Set Pressure (psig) 1 psi incr. 5 psi incr. 1720 1740 1760 1780 1800 1820 1840 1860 1880 1900 1920 1940 1960 1980 2000 2020 2040 2060 2080 2100 2120 2140 2160 2180 2200 2220 2240 2260 2280 2300 2320 2340 2360 2380 2400 2420 2440 2460 2480 2500 2520 2540 2560 2580 2600 2620 2640 2660 2680 2700 2720 2740 2760 2780 2800 2820 2840 2860 2880 2900 D 0.110 6.0 30.3 10744 10884 11025 11167 11309 11452 11596 11740 11885 12031 12178 12326 12474 12623 12773 12924 13076 13229 13383 13538 13694 13851 14009 14169 14329 14491 14654 14818 14983 15150 15318 15488 15659 15832 16006 16182 16360 16539 16720 16904 17089 17276 17465 17657 17850 18046 18245 18446 18650 18856 19066 19278 19493 19712 19934 20159 20388 20621 20858 21100 E 0.196 10.8 54.1 19143 19394 19645 19897 20151 20406 20662 20919 21178 21438 21699 21962 22227 22493 22760 23029 23300 23573 23847 24123 24401 24681 24962 25246 25532 25820 26110 26403 26698 26995 27295 27597 27902 28210 28520 28834 29151 29470 29793 30120 30450 30783 31120 31461 31807 32156 32510 32868 33231 33599 33972 34350 34734 35123 35519 35921 36329 36744 37166 37596 USCS UNITS (United States Customary System) F 0.307 16.9 84.7 29985 30377 30770 31166 31563 31962 32363 32766 33172 33579 33989 34400 34815 35231 35650 36072 36496 36923 37352 37785 38220 38658 39100 39544 39992 40443 40898 41356 41818 42283 42753 43226 43704 44186 44673 45164 45660 46160 46666 47177 47694 48217 48745 49279 49820 50367 50921 51482 52051 52627 53211 53803 54405 55015 55634 56264 56903 57553 58215 58888 G 0.503 27.7 138 49129 49771 50416 51063 51714 52368 53025 53686 54350 55017 55688 56363 57042 57725 58411 59102 59797 60496 61200 61908 62621 63340 64063 64791 65525 66264 67008 67759 68516 69279 70048 70824 71606 72396 73193 73998 74811 75631 76460 77298 78144 79000 79866 80741 81627 82523 83431 84351 85282 86226 87183 88154 89139 90138 91153 92185 93233 94298 95382 96485 ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq. in. H J K L M N 0.785 1.287 1.838 2.853 3.60 4.34 43.3 71.0 101 157 198 239 216 355 507 787 994 1198 76673 125705 179523 77674 127347 181868 78681 128996 184223 79691 130654 186590 80707 132319 188968 81728 133992 191358 82753 135674 193759 83784 137364 196173 84821 139063 198600 85862 140771 201039 86910 142488 203491 87963 144215 205957 89022 145951 90087 147698 91159 149454 92237 151222 93321 153000 94413 154789 95511 156590 96617 158402 97730 160227 98850 162064 99979 163915 101115 165778 102260 167655 103414 169546 104576 171452 105747 173372 106928 175308 108119 177260 109319 179229 110530 181214 111752 183217 112985 185237 114229 187277 115484 189336 116752 191415 118033 119327 ) 50 Please refer to Warranty and Warnings on page 63. Capacity in pounds per hour of steam at 10% overpressure. Valve discharging to atmospheric pressure. Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. P 6.38 352 1761 Q 11.05 610 3051 R 16.0 883 4418 T 26.0 1436 7180 T2 27.872 1539 7697 Equivalents and Conversion Factors This table may be used in two ways (1) Multiply the unit under column A by the figure under column B, the result is the unit under column C. (2) Divide the unit under column C by the figure under column B, the result is then the unit under column A. A MULTIPLY B BY C TO OBTAIN Atmospheres Atmospheres Atmospheres Atmospheres Atmospheres Atmospheres Atmospheres Atmospheres 14.70 1.033 29.92 760.0 407.2 33.93 1.013 101.3 Pounds per square inch Kilograms per sq. cm Inches of mercury Millimeters of mercury Inches of water Feet of water Bars KiloPascals Barrels Bars Bars Bars 42.00 14.50 1.020 100.0 Gallons (U.S.) Pounds per square inch Kilograms per sq. cm KiloPascals Centimeters 0.3937 Centimeters 0.03281 Centimeters 0.010 Centimeters 0.01094 Cubic centimeters 0.06102 Cubic feet 7.481 Cubic feet 0.1781 Cubic feet per minute 0.02832 Cubic feet per second 448.8 Cubic inches 16.39 Cubic inches 0.004329 Cubic meters 264.2 Cubic meters per hour 4.403 Cubic meters per minute 35.31 Standard cubic feet per min. 60.00 Standard cubic feet per min. 1440. Standard cubic feet per min. 0.02716 Standard cubic feet per min. 1.630 Standard cubic feet per min. 39.11 Standard cubic feet per min. 0.02832 Standard cubic feet per min. 1.699 Standard cubic feet per min. 40.78 Inches Feet Meters Yards Cubic inches Gallons Barrels Cubic meters per minute Gallons per minute Cubic centimeters Gallons Gallons Gallons per minute Cubic feet per minute Standard cubic ft. per hr Standard cubic ft. per day Nm3/min. Nm3/hr. Nm3/day Sm3 /min. Sm3/hr. Sm3 /day Feet Feet Feet Feet of water Feet of water Meters Yards Centimeters Inches of mercury Pounds per square inch Gallons(U.S.) Gallons(U.S.) Gallons(U.S.) Gallons(Imperial) Gallons(U.S.) Gallons(U.S.) Gallons of water Gallons of liquid per minute Gallons per minute Gallons per minute Gallons per minute Gallons per minute Gallons per minute Grams Inches Inches Inches Inches Inches Inches Inches Inches of of of of mercury mercury mercury mercury 0.3048 0.3333 30.48 0.8818 0.4335 3785. 0.1337 231.0 277.4 0.8327 3.785 8.337 500 x Sp. Gr. 0.002228 227.0 x SG .06309 3.785 .2271 .03527 Cubic centimeters Cubic feet Cubic inches Cubic inches Gallons (Imperial) Liters Pounds (at 60F) Pounds per hour liquid (at 60F) Cubic feet per second Kilograms per hour Liters per second Liters per minute M3/hr. Ounces 2.540 0.08333 0.0254 0.02778 1.133 0.4912 0.03342 0.03453 Centimeters Feet Meters Yards Feet of water Pounds per square inch Atmospheres Kilograms per sq. cm A MULTIPLY B BY Inches of water Inches of water 0.03613 0.07355 Kilograms Kilograms Kilograms Kilograms per minute Kilograms per sq. cm Kilograms per sq. cm Kilograms per sq. cm Kilograms per cubic meter KiloPascals KiloPascals KiloPascals Liters Liters Liters Liters per hour 2.205 0.001102 35.27 132.3 14.22 0.9678 28.96 16.018 0.1450 0.0100 0.01020 0.03532 1000. 0.2642 0.004403 C TO OBTAIN Pounds per sq. in. Inches of mercury Pounds Short tons (2000 lbs.) Ounces Pounds per hour Pounds per sq. in. Atmospheres Inches of mercury Pounds per cubic foot Pounds per sq. in. Bars Kilograms per sq. cm Cubic feet Cubic centimeters Gallons Gallons per minute Meters Meters Meters Meters 3.281 1.094 100.0 39.37 Pounds Pounds Pounds Pounds Pounds Pounds Pounds per hour Pounds per hour Pounds per hour liquid 0.1199 Gallons H2 O @ 60F (U.S.) 453.6 Grams 0.0005 Short tons (2000 lbs.) 0.4536 Kilograms 0.0004536 Metric tons 16.00 Ounces 6.323/M.W. Cubic feet per minute .4536 Kilograms per hour 0.002/Sp.Gr. Gallons per minute liquid (at 60F) 27.68 Inches of water 2.307 Feet of water 2.036 Inches of mercury 0.07031 Kilograms per sq. cm 0.0680 Atmospheres 51.71 Millimeters of mercury 0.7032 Meters of water 0.06895 Bar 6.895 KiloPascals Pounds Pounds Pounds Pounds Pounds Pounds Pounds Pounds Pounds per sq. per sq. per sq. per sq. per sq. per sq. per sq. per sq. per sq. inch inch inch inch inch inch inch inch inch Specific gravity (of gas or vapors) Square centimeter Square inch Square inch SSU SSU Water (cubic feet) Temperature: Centigrade Kelvin Fahrenheit Fahrenheit +460 Fahrenheit (F+460) 5/9 Feet Yards Centimeters Inches 28.97 Molecular weight (of gas or vapors) 0.1550 Square inch 6.4516 Square centimeter 645.16 Square millimeter 0.2205 x SG Centipoise 0.2162 Centistoke 62.4 = = = = = Pounds (at 60F) 5/9 (Fahrenheit - 32) Centigrade + 273 9/5 (Centigrade)+32 Rankine Kelvin Please refer to Warranty and Warnings on page 63. 51 Air Capacities Styles JOS and JBS Set Pressures 0.35-88 barg Capacity in standard cubic meters of air per minute at 16C and 10% overpressure.† Valve discharging to atmospheric pressure. Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. METRIC UNITS Shaded values are JOS only Set Pressure (barg) D 71.0 E 126 F 198 ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq mm G H J K L M N P 325 506 830 1186 1841 2323 2800 4116 Q 7129 R 10323 T 16774 T2 17981 Set Pressure (kPag) 1 bar incr. 5 bar incr. 0.8 4.4 1.5 7.9 2.4 12.3 4.0 20.3 6.3 31.6 10.3 51.9 14.8 74.2 89.2 446 129 646 209 1049 225 1125 100 kPa incr. 500 kPa incr. 2.5 2.6 2.6 2.7 2.8 2.9 2.9 3.0 3.1 3.1 4.6 7.7 10.9 14.1 17.2 20.4 23.6 26.7 29.9 33.1 36.2 39.4 42.6 45.7 48.9 52.1 55.2 58.4 61.6 64.7 67.9 71.1 74.2 77.4 80.6 83.7 86.9 90.0 93.2 96.4 99.5 102 105 109 112 115 118 121 124 128 131 134 137 140 3.4 3.6 3.7 3.8 3.9 4.0 4.2 4.3 4.4 4.5 4.6 4.7 4.8 5.0 7.2 12.2 17.1 22.1 27.0 32.0 36.9 41.9 46.9 51.8 56.8 61.7 66.7 71.7 76.6 81.6 86.5 91.5 96.4 101 106 111 116 121 126 131 136 141 146 151 155 160 165 170 175 180 185 190 195 200 205 210 215 220 5.6 5.9 6.1 6.3 6.5 6.7 6.9 7.0 7.2 7.4 7.6 7.8 8.0 8.1 11.8 19.9 28.1 36.2 44.3 52.4 60.6 68.7 76.8 84.9 93.1 101 109 117 125 133 141 149 158 166 174 182 190 198 206 214 223 231 239 247 255 263 271 279 288 296 304 312 320 328 336 344 353 361 8.8 9.2 9.5 9.8 10.1 10.4 10.7 11.0 11.3 11.6 11.9 12.2 12.5 12.7 18.5 31.1 43.8 56.5 69.2 81.9 94.5 107 119 132 145 157 170 183 196 208 221 234 246 259 272 284 297 310 322 335 348 360 373 386 398 411 424 436 449 462 474 487 500 512 525 538 551 563 14.5 15.1 15.6 16.1 16.6 17.1 17.6 18.1 18.6 19.0 19.5 20.0 20.5 20.9 30.4 51.1 71.9 92.7 113 134 155 175 196 217 238 259 279 300 321 342 362 383 404 425 446 466 487 508 529 550 570 591 612 633 653 674 695 716 737 757 778 799 820 841 861 882 903 924 20.7 21.6 22.3 23.1 23.8 24.5 25.2 25.9 26.5 27.2 27.9 28.6 29.2 29.9 43.4 73.0 102 132 162 191 221 251 280 310 340 369 399 429 458 488 518 548 577 607 637 666 696 726 755 785 815 844 874 904 933 963 993 1023 1052 1082 1112 1141 1171 1201 1230 1260 1290 1319 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95 1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 1.5 1.5 1.6 1.6 1.7 1.7 1.7 2.6 4.3 6.1 7.9 9.7 11.4 13.2 15.0 16.8 18.5 20.3 22.1 23.9 25.6 27.4 29.2 31.0 32.7 34.5 36.3 38.1 39.9 41.6 43.4 45.2 47.0 48.7 50.5 52.3 54.1 55.8 57.6 59.4 61.2 63.0 64.7 66.5 68.3 70.1 71.8 73.6 75.4 77.2 78.9 23.0 115 34.7 35.8 37.0 38.0 39.1 40.2 41.2 42.3 43.3 44.4 45.4 46.5 67.4 113 159 205 251 297 343 389 435 482 528 574 620 666 712 758 804 850 896 942 988 1034 1081 1127 1173 1219 1265 1311 1357 1403 1449 1495 1541 1587 1634 1680 1726 1772 1818 1864 1910 1956 2002 2048 29.0 145 46.6 48.0 49.4 50.7 52.0 53.3 54.7 56.0 57.3 58.6 85.1 143 201 259 317 375 433 491 550 608 666 724 782 840 898 957 1015 1073 1131 1189 1247 1305 1364 1422 1480 1538 1596 1654 1713 1771 1829 1887 1945 2003 2061 2120 2178 †Capacities below 2.0 bar set pressure are calculated at 0.2 bar overpressure. 52 Please refer to Warranty and Warnings on page 63. 35.0 175 56.2 57.9 59.5 61.1 62.7 64.3 65.9 67.5 69.1 70.7 102 172 242 312 382 452 522 593 663 733 803 873 943 1013 1083 1153 1223 1294 1364 1434 1504 1574 1644 1714 1784 1854 1924 1995 2065 2135 2205 2275 2345 2415 51.5 257 80.2 82.7 85.1 87.6 89.9 92.2 94.6 96.9 99.3 101 104 150 253 356 459 562 665 768 871 974 1077 1180 1284 1387 1490 1593 1696 1799 1902 2005 2108 2211 2314 2417 2520 2623 2726 2829 2932 3035 3138 3241 3344 3448 3551 124 129 134 139 143 147 151 155 159 163 167 172 176 180 261 439 617 796 974 1153 1331 1510 1688 1866 2045 2223 2402 2580 2759 2937 3116 3294 3473 3651 207 213 219 225 231 237 243 249 254 260 378 635 894 1152 1411 1669 1928 2186 2444 2703 337 347 357 366 376 385 395 404 414 423 614 1033 1453 1873 2293 2713 3133 3552 3972 4392 361 372 382 392 403 413 423 433 444 454 658 1107 1557 2008 2458 2908 3358 3808 4258 4709 35 40 45 50 55 60 65 70 75 80 85 90 95 100 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 6600 6800 7000 7200 7400 7600 7800 8000 8200 8400 8600 8800 Air Capacities Styles JOS and JBS Set Pressures 90-410 barg Capacity in standard cubic meters of air per minute at 16C and 10% overpressure. Valve discharging to atmospheric pressure. Set Pressure (barg) D 71.0 E 126 F 198 ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq mm G H J K L M N P 325 506 830 1186 1841 2323 2800 4116 Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. Set T2 Q R T Pressure 7129 10323 16774 17981 (kPag) 1 bar incr. 5 bar incr. 0.8 4.4 1.5 7.9 2.4 12.3 4.0 20.3 6.3 31.6 10.3 51.9 14.8 74.2 23.0 115 89.2 446 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144 146 148 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 80.7 82.5 84.3 86.0 87.8 89.6 91.4 93.2 94.9 96.7 98.5 100 102 103 105 107 109 110 112 114 116 118 119 121 123 125 126 128 130 132 134 142 151 160 169 178 187 196 205 214 222 231 240 249 258 267 276 285 293 302 311 320 329 338 347 356 365 143 147 150 153 156 159 162 166 169 172 175 178 181 185 188 191 194 197 200 204 207 210 213 216 219 223 226 229 232 235 238 254 270 286 302 318 333 349 365 381 397 412 428 444 460 476 492 507 523 539 555 571 587 602 618 634 650 225 230 235 240 245 250 255 260 265 270 275 279 284 289 294 299 304 309 314 319 324 329 334 339 344 349 354 359 364 369 374 398 423 448 473 498 522 547 572 597 622 646 671 696 721 746 770 795 820 845 369 377 385 393 401 409 418 426 434 442 450 458 466 474 483 491 499 507 515 523 531 539 548 556 564 572 580 588 596 604 613 653 694 734 775 816 856 897 938 978 1019 576 589 601 614 627 639 652 665 677 690 703 715 728 741 753 766 779 791 804 817 829 842 855 868 880 893 906 918 931 944 956 1020 1083 1146 1210 944 965 986 1007 1028 1048 1069 1090 1111 1132 1152 1173 1194 1215 1236 1256 1277 1298 1319 1339 1360 1381 1402 1423 1443 1464 1485 1506 1527 1547 1568 1672 1776 1880 1349 1379 1408 1438 1468 1497 1527 1557 1587 1616 1646 1676 1705 1735 1765 1794 1824 1854 1883 1913 1943 1972 2002 2032 2062 2091 2121 2151 2180 2210 2240 2094 2140 2186 2233 2279 2325 2371 METRIC UNITS 29.0 145 35.0 175 51.5 257 129 646 209 1049 Please refer to Warranty and Warnings on page 63. 225 1125 100 kPa incr. 500 kPa incr. 9000 9200 9400 9600 9800 10000 10200 10400 10600 10800 11000 11200 11400 11600 11800 12000 12200 12400 12600 12800 13000 13200 13400 13600 13800 14000 14200 14400 14600 14800 15000 16000 17000 18000 19000 20000 21000 22000 23000 24000 25000 26000 27000 28000 29000 30000 31000 32000 33000 34000 35000 36000 37000 38000 39000 40000 41000 53 Water Capacities Styles JLT-JOS and JLT-JBS Differential Pressures 1-80 bar† Diff. * Pressure D P 71.0 (bar) 1 44.6 2 63.1 3 77.2 4 89.2 5 99.7 6 109 7 118 8 126 9 133 10 141 11 147 12 154 13 160 14 166 15 172 16 178 17 183 18 189 19 194 20 199 21 204 22 209 23 214 24 218 25 223 26 227 27 231 28 236 29 240 30 244 31 248 32 252 33 256 34 260 35 263 36 267 37 271 38 275 39 278 40 282 41 285 42 289 43 292 44 295 45 299 46 302 47 305 48 309 49 312 50 315 52 321 54 327 56 333 58 339 60 345 62 351 64 356 66 362 68 367 70 373 72 378 74 383 76 389 78 394 80 399 Capacity in liters per minute of water at 21C and 10% overpressure. P* Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. METRIC UNITS ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq. mm. H J K L M N 506 830 1186 1841 2323 2800 E 126 F 198 G 325 79.5 112 137 159 177 194 210 224 238 251 263 275 286 297 307 318 327 337 346 355 364 372 381 389 397 405 413 420 428 435 442 449 456 463 470 477 483 490 496 502 509 515 521 527 533 539 545 550 556 562 573 584 595 605 615 626 636 645 655 665 674 683 693 702 711 124 176 215 249 278 305 329 352 373 393 413 431 449 465 482 498 513 528 542 556 570 584 597 610 622 635 647 659 670 682 693 704 715 726 736 747 757 767 777 787 797 807 816 826 835 844 853 862 871 880 898 915 931 948 964 980 996 1011 1026 1041 1056 1071 1085 1099 1113 204 288 353 408 456 499 539 577 612 645 676 706 735 763 790 816 841 865 889 912 935 957 978 999 1020 1040 1060 1079 1098 1117 1136 1154 1172 1189 1207 1224 1241 1257 1274 1290 1306 1322 1338 1353 1368 1383 1398 1413 1428 1442 1471 1499 1526 1553 1580 1606 1632 1657 1682 1707 1731 1755 1778 1802 1825 318 450 551 636 712 780 842 900 955 1007 1056 1103 1148 1191 1233 1273 1312 1351 1388 1424 1459 1493 1527 1560 1592 1623 1654 1685 1714 1744 1773 1801 1829 1856 1883 1910 1937 1963 1988 2014 2039 2063 2088 2112 2136 2159 2183 2206 2229 2251 2296 2340 2383 2425 2466 2507 2547 2587 2625 2664 2702 2739 2776 2812 2848 522 738 904 1044 1167 1278 1381 1476 1566 1651 1731 1808 1882 1953 2022 2088 2152 2215 2275 2334 2392 2448 2503 2557 2610 2662 2712 2762 2811 2859 2906 2953 2999 3044 3088 3132 3175 3218 3260 3302 3343 3383 3423 3463 3502 3541 3579 3617 3654 3691 3764 3836 3906 3976 4044 4110 4176 4241 4305 4368 4430 4491 4551 4610 4669 745 1054 1291 1491 1667 1826 1972 2108 2236 2357 2472 2582 2688 2789 2887 2982 3074 3163 3250 3334 3416 3497 3575 3652 3728 3801 3874 3945 4015 4083 4151 4217 4283 4347 4411 4473 4535 4596 4656 4715 4774 4832 4889 4945 5001 5057 5111 5165 5219 5272 5376 5479 5579 5678 5775 5870 5964 6057 6148 6238 6326 6414 6500 6585 6668 1157 1636 2004 2314 2587 2834 3062 3273 3472 3659 3838 4009 4172 4330 4482 4629 4771 4910 5044 5175 5303 5428 5550 5669 5786 5901 6013 6124 6232 6339 6443 6547 6648 6748 6847 6944 7039 7134 7227 7319 7410 7500 7589 7677 7763 7849 7934 8018 8101 8183 8345 8504 8660 8814 8964 9113 9258 9402 9543 9683 9820 9956 10089 10221 10351 *Differential Pressure ( 1460 2065 2529 2920 3265 3577 3863 4130 4381 4618 4843 5058 5265 5464 5656 5841 6021 6195 6365 6531 6692 6849 7003 7154 7301 7446 7588 7727 7864 7998 8131 8261 8389 8515 8639 8762 8883 9002 9120 9236 9351 9464 9576 9687 9796 9904 10011 10117 10222 10326 10531 10731 10928 11122 11312 11499 11683 11864 12042 12218 12391 12562 12731 12897 13062 1760 2489 3049 3521 3936 4312 4658 4979 5281 5567 5839 6098 6347 6587 6818 7042 7259 7469 7674 7873 8068 8257 8443 8625 8802 8977 9148 9316 9481 9643 9802 9959 10113 10265 10415 10563 10709 10853 10994 11134 11273 11409 11544 11678 11810 11940 12070 12197 12324 12449 12695 12937 13175 13408 13637 13862 14084 14303 14518 14730 14939 15145 P 4116 Q 7129 2588 3660 4482 5176 5787 6339 6847 7320 7764 8184 8583 8965 9331 9683 10023 10352 10671 10980 11281 11574 11860 12139 12412 12679 12940 13197 13448 13695 13937 14175 14410 14640 14867 15091 15311 15528 15743 15954 16162 16368 16572 16773 16971 17167 17361 17553 17743 17931 18117 18300 18663 19018 19367 19710 20047 20379 20705 21026 21342 21654 21961 22264 4482 6339 7764 8965 10023 10980 11859 12678 13447 14175 14867 15528 16162 16772 17361 17930 18482 19018 19539 20046 20541 21025 21497 21960 22413 22856 23292 23719 24139 24552 24958 25357 25750 26137 26519 26895 27266 27632 27993 28350 28702 29050 29394 29734 R 10323 6490 9179 11242 12981 14513 15898 17172 18358 19471 20525 21527 22484 23402 24285 25138 25962 26761 27537 28292 29027 29743 30443 31128 T 16774 10547 14916 18268 21094 23584 25835 27905 29832 31641 33353 34981 36536 38028 39464 40849 42189 43487 44748 45974 47169 48333 49471 50583 P) equals inlet pressure (set pressure plus overpressure) at flowing conditions minus back pressure. †See pages 14 to 43 for Minimum and Maximum Set Pressure Limits. 54 Please refer to Warranty and Warnings on page 63. Diff. * Pressure P (kPa) 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 4600 4700 4800 4900 5000 5200 5400 5600 5800 6000 6200 6400 6600 6800 7000 7200 7400 7600 7800 8000 Water Capacities Styles JLT-JOS and JLT-JBS Differential Pressures 82-455 bar† Diff. * Pressure D P 71.0 (bar) 82 404 84 408 86 413 88 418 90 423 92 428 94 432 96 437 98 441 100 446 102 450 104 455 106 459 108 463 110 468 112 472 114 476 116 480 118 484 120 488 122 492 124 496 126 500 128 504 130 508 132 512 134 516 136 520 138 524 140 527 142 531 144 535 146 539 148 542 150 546 160 564 170 581 180 598 190 615 200 631 210 646 220 661 230 676 240 691 250 705 260 719 270 733 280 746 290 759 300 772 310 785 320 798 330 810 340 822 350 834 360 846 370 858 380 869 390 881 400 892 410 903 420 914 430 925 440 936 450 946 455 951 Capacity in liters per minute of water at 21C and 10% overpressure. P* Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. METRIC UNITS ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq. mm. H J K L M N 506 830 1186 1841 2323 2800 E 126 F 198 G 325 719 728 737 745 754 762 770 779 787 795 803 810 818 826 833 841 848 856 863 870 878 885 892 899 906 913 920 927 934 940 947 954 960 967 973 1005 1036 1066 1095 1124 1152 1179 1205 1231 1257 1282 1306 1330 1354 1377 1399 1422 1444 1466 1487 1508 1529 1549 1570 1590 1609 1629 1648 1667 1686 1696 1127 1141 1154 1168 1181 1194 1207 1220 1232 1245 1257 1270 1282 1294 1306 1318 1329 1341 1352 1364 1375 1386 1397 1409 1419 1430 1441 1452 1463 1473 1484 1494 1504 1515 1525 1575 1623 1670 1716 1761 1804 1847 1888 1929 1969 2008 2046 2083 2120 2157 2192 2227 2262 2296 2329 2362 2395 1847 1870 1892 1914 1935 1957 1978 1999 2019 2040 2060 2080 2100 2120 2140 2159 2178 2197 2216 2235 2253 2272 2290 2308 2326 2344 2362 2379 2397 2414 2431 2448 2465 2482 2499 2581 2660 2737 2812 2885 2956 3026 3094 3161 3226 3290 3352 3414 2883 2918 2953 2987 3021 3054 3087 3120 3152 3184 3216 3247 3278 3309 3339 3370 3400 3429 3459 3488 3517 3546 3574 3602 3630 3658 3686 3713 3740 3767 3794 3821 3847 3874 3900 4028 4152 4272 4389 4503 4727 4785 4841 4897 4953 5007 5061 5115 5168 5220 5272 5324 5375 5425 5475 5525 5574 5623 5671 5719 5766 5813 5860 5906 5952 5998 6043 6088 6133 6177 6221 6265 6308 6351 6394 6604 6807 7004 7196 7383 6751 6833 6914 6994 7073 7151 7228 7305 7381 7456 7530 7603 7676 7748 7820 7890 7960 8030 8099 8167 8235 8302 8369 8435 8501 8566 8631 8695 8758 8822 8885 8947 9009 9070 9131 9431 10480 10607 10732 10857 10979 11101 11221 11339 11457 11573 11688 11802 11915 12027 12138 12248 12357 P 4116 Q 7129 R 10323 T 16774 13224 13384 Diff. * Pressure P (kPa) 8200 8400 8600 8800 9000 9200 9400 9600 9800 10000 10200 10400 10600 10800 11000 11200 11400 11600 11800 12000 12200 12400 12600 12800 13000 13200 13400 13600 13800 14000 14200 14400 14600 14800 15000 16000 17000 18000 19000 20000 21000 22000 23000 24000 25000 26000 27000 28000 29000 30000 31000 32000 33000 34000 35000 36000 37000 38000 39000 40000 41000 42000 43000 44000 45000 45500 *Differential Pressure ( P) equals inlet pressure (set pressure plus overpressure) at flowing conditions minus back pressure. †See pages 14 to 43 for Minimum and Maximum Set Pressure Limits. Please refer to Warranty and Warnings on page 63. 55 Saturated Steam Capacities Unfired Pressure Vessel Service Styles JOS and JBS Set Pressures 0.35-76 barg METRIC UNITS Capacity in kilograms per hour of steam at 10% overpressure.† Valve discharging to atmospheric pressure. Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. Shaded values are JOS only Set Pressure (barg) *0.1 bar incr. *0.5 bar incr. 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 D 71.0 3.9 19.9 E 126 7.1 35.6 69.7 71.5 73.4 75.2 77.0 78.8 80.6 117 156 196 236 276 316 356 396 436 476 516 556 596 636 676 716 756 796 836 916 996 1076 1155 1235 1315 1395 1475 1555 1635 1715 1795 1875 1955 2035 2115 2195 2275 2355 2434 2514 2594 2674 2754 2834 2914 2994 3074 114 117 121 124 127 130 134 137 140 143 208 279 350 421 492 564 635 706 777 849 920 991 1062 1133 1205 1276 1347 1418 1489 1632 1774 1917 2059 2202 2344 2487 2629 2771 2914 3056 3199 3341 3484 3626 3768 3911 4053 4196 4338 4481 4623 4766 4908 5050 5193 5335 5478 F 198 11.1 55.7 155 162 168 173 179 184 189 194 199 204 209 215 220 225 326 437 548 660 772 883 995 1106 1218 1329 1441 1552 1664 1776 1887 1999 2110 2222 2333 2556 2780 3003 3226 3449 3672 3895 4118 4341 4564 4787 5011 5234 5457 5680 5903 6126 6349 6572 6795 7018 7242 7465 7688 7911 8134 8357 8580 ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq. mm. G H J K L M N P 325 506 830 1186 1841 2323 2800 4116 18.2 28.5 46.7 66.7 103 130 157 231 91.3 142 233 333 518 654 788 1159 255 398 652 932 266 415 680 972 275 430 705 1007 1563 284 444 728 1040 1614 3611 293 458 751 1072 1665 2101 2533 3723 302 471 773 1104 1713 2162 2607 3832 310 485 795 1135 1762 2224 2681 3941 319 497 816 1165 1809 2283 2753 4047 327 510 837 1196 1856 2343 2824 4152 335 523 858 1226 1904 2402 2896 4257 344 536 880 1257 1951 2462 2968 4363 352 549 901 1287 1998 2521 3039 4468 360 562 922 1317 2045 2580 3111 4574 368 575 943 1348 2092 2640 3183 4679 535 835 1369 1955 3034 3829 4616 6786 716 1118 1833 2618 4065 5129 6183 9090 899 1403 2301 3286 5101 6437 7760 11408 1082 1688 2769 3954 6138 7745 9337 13727 1265 1974 3236 4622 7175 9053 10914 16045 1447 2259 3704 5290 8211 10361 12491 18363 1630 2544 4172 5958 9248 11669 14068 20681 1813 2829 4639 6626 10285 12978 15645 23000 1996 3115 5107 7293 11321 14286 17222 25318 2178 3400 5574 7961 12358 15594 18799 27636 2361 3685 6042 8629 13395 16902 20376 29954 2544 3970 6510 9297 14431 18210 21953 32272 2727 4256 6977 9965 15468 19518 23530 34591 2909 4541 7445 10633 16505 20826 25107 36909 3092 4826 7913 11300 17541 22134 26684 39227 3275 5111 8380 11968 18578 23442 28261 41545 3458 5397 8848 12636 19615 24750 29838 43863 3641 5682 9316 13304 20651 26058 31415 46182 3823 5967 9783 13972 21688 27367 32992 48500 4189 6538 10718 15308 23761 29983 36146 53136 4554 7108 11654 16643 25834 32599 39300 57773 4920 7678 12589 17979 27908 35215 42454 62409 5285 8249 13524 19315 29981 37831 45608 67046 5651 8819 14460 20650 32054 40447 48762 71682 6017 9390 15395 21986 34128 43064 51916 76319 6382 9960 16330 23322 36201 45680 55070 80955 6748 10531 17265 24657 38274 48296 58223 85591 7113 11101 18201 25993 40348 50912 61377 90228 7479 11672 19136 27329 42421 53528 64531 94864 7844 12242 20071 28665 44494 56144 67685 99501 8210 12813 21007 30000 46568 58761 70839 104137 8575 13383 21942 31336 48641 61377 73993 108774 8941 13954 22877 32672 50714 63993 77147 113410 9306 14524 23812 34007 52788 66609 80301 118046 9672 15095 24748 35343 54861 69225 83455 122683 10037 15665 25683 36679 56934 71841 86609 127319 10403 16236 26618 38014 59008 74458 89763 131956 10768 16806 27554 39350 61081 77074 92917 136592 11134 17376 28489 40686 63154 79690 96071 141229 11500 17947 29424 42022 65227 82306 99225 145865 11865 18517 30359 43357 67301 84922 102379 150502 12231 19088 31295 44693 69374 87538 105533 155138 12596 19658 32230 46029 71447 90155 108687 159774 12962 20229 33165 47364 73521 92771 13327 20799 34101 48700 75594 95387 13693 21370 35036 50036 77667 98003 14058 21940 35971 51372 79741 †Capacities below 2.0 bar set pressure are calculated at 0.2 bar overpressure. *Not valid below 2.0 bar set pressure. 56 Please refer to Warranty and Warnings on page 63. Q 7129 401 2007 5606 5843 6054 6254 6449 6638 6827 7009 7192 7374 7557 7739 7922 8104 11754 15744 19759 23775 27790 31805 35820 39835 43850 47865 51880 55895 59910 63926 67941 71956 75971 79986 84001 92031 100061 108092 116122 124152 132182 140212 148243 156273 164303 R 10323 581 2906 T 16774 944 4723 9338 9611 9885 10149 10414 10678 10942 11206 11471 11735 17020 22798 28611 34425 40239 46052 51866 57680 63494 69307 75121 80935 86748 92562 98376 104190 110003 115817 121631 15174 15618 16063 16493 16922 17352 17781 18211 18640 19069 27658 37046 46494 55941 65388 74835 84283 93730 103177 112625 122072 131519 140966 150414 159861 169308 178756 188203 197650 Set T2 Pressure 17981 (kPag) 1012 10 kPa incr. 5063 50 kPa incr. 35 40 45 50 16267 55 16743 60 17220 65 17680 70 18141 75 18601 80 19061 85 19522 90 19982 95 20442 100 29649 200 39714 300 49841 400 59969 500 70096 600 80224 700 90351 800 100479 900 110606 1000 120734 1100 130861 1200 140989 1300 151116 1400 161244 1500 171371 1600 181499 1700 191626 1800 201754 1900 211881 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 6600 6800 7000 7200 7400 7600 Saturated Steam Capacities Unfired Pressure Vessel Service Styles JOS and JBS Set Pressures 78-200 barg Set Pressure (barg) 0.1 bar incr. 0.5 bar incr. 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144 146 148 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 182 184 186 188 190 192 196 200 D 71.0 3.9 19.9 3154 3234 3314 3394 3474 3554 3634 3714 3780 3866 3953 4040 4127 4215 4304 4393 4482 4572 4663 4754 4846 4938 5031 5124 5218 5313 5409 5505 5602 5700 5799 5898 5999 6100 6202 6306 6410 6516 6622 6730 6839 6950 7062 7175 7290 7406 7525 7644 7766 7890 8016 8143 8274 8406 8541 8679 8820 8964 9262 9574 Capacities certified by the National Board of Boiler and Pressure Vessel Inspectors and in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII. METRIC UNITS E 126 7.1 35.6 5620 5763 5905 6047 6190 6332 6475 6617 6736 6889 7044 7199 7355 7512 7669 7828 7987 8147 8309 8471 8634 8799 8964 9131 9298 9467 9638 9809 9982 10157 10332 10510 10689 10869 11052 11236 11422 11610 11800 11992 12187 12384 12583 12785 12990 13197 13408 13621 13838 14059 14283 14511 14743 14979 15220 15465 15716 15973 16503 17059 F 198 11.1 55.7 8803 9026 9249 9473 9696 9919 10142 10365 10550 10791 11033 11276 11520 11766 12013 12261 12511 12762 13015 13269 13524 13782 14041 14302 14565 14829 15096 15365 15636 15909 16184 16462 16742 17025 17311 17599 17891 18186 18483 18784 19089 19397 19710 20026 20346 20671 21001 21336 21675 22021 22372 22728 23092 23462 23839 24224 24617 25018 25849 26721 Capacity in kilograms per hour of steam at 10% overpressure. Valve discharging to atmospheric pressure. ORIFICE LETTER DESIGNATION AND EFFECTIVE AREA, sq. mm. G H J K L M N P 325 506 830 1186 1841 2323 2800 4116 18.2 28.5 46.7 66.7 103 130 157 231 91.3 142 233 333 518 654 788 1159 14424 22511 36906 52707 81814 14789 23081 37842 54043 83887 15155 23652 38777 55379 85961 15520 24222 39712 56714 88034 15886 24793 40647 58050 90107 16252 25363 41583 59386 92181 16617 25934 42518 60721 94254 16983 26504 43453 62057 96327 17286 26978 44230 63167 98050 17681 27593 45240 64608 100287 18077 28212 46254 66056 102535 18475 28834 47273 67512 104794 18876 29458 48297 68975 107065 19278 30086 49327 70445 19683 30718 50362 71923 20089 31353 51402 73410 20498 31991 52449 74904 20910 32633 53502 76408 21324 33279 54561 77920 21740 33929 55626 79442 22159 34583 56698 80973 22581 35241 57778 82514 23006 35904 58864 84065 23433 36571 59958 85628 23864 37243 61059 87201 24297 37919 62169 88785 24734 38601 63287 90382 25175 39289 64414 91991 25618 39981 65549 26066 40680 66694 26517 41384 67849 26972 42094 69013 27432 42811 70189 27895 43535 71375 28363 44265 72572 28836 45003 73782 29314 45748 75004 29796 46501 76239 30284 47263 77487 30777 48033 78749 31277 48812 80027 31782 49600 81319 32293 50399 82628 32812 51207 83954 33337 52027 85298 33869 52858 86660 34409 53701 34957 35514 36080 36655 37239 37835 38441 39059 39690 40334 40991 42352 43781 Q 7129 401 2007 R 10323 581 2906 T 16774 944 4723 Please refer to Warranty and Warnings on page 63. Set T2 Pressure 17981 (kPag) 1012 10 kPa incr. 5063 50 kPa incr. 7800 8000 8200 8400 8600 8800 9000 9200 9400 9600 9800 10000 10200 10400 10600 10800 11000 11200 11400 11600 11800 12000 12200 12400 12600 12800 13000 13200 13400 13600 13800 14000 14200 14400 14600 14800 15000 15200 15400 15600 15800 16000 16200 16400 16600 16800 17000 17200 17400 17600 17800 18000 18200 18400 18600 18800 19000 19200 19600 20000 57 Pressure Relief Valves Custom Designed by Crosby Engineering Crosby can design and manufacture pressure relief valves to meet your unique requirements. Application: ♦ Emergency depressurizing system for overpressure protection and protection in the event of a fire or runaway exothermic reaction. Solution: ♦ Crosby® Style JBS pressure relief valve with special axial pneumatic actuator custom designed by Crosby Engineering. ♦ Standard direct operating pressure relief valve which can also be opened pneumatically. ♦ Pneumatic operation as a result of remote sensing of pressure, temperature or other process variables. ♦ Direct in line loading of valve spindle without the use of levers or cams. ♦ Full lift of valve disc with zero pressure at the inlet port. ♦ Remote valve lift indication. To find out more about this unique pressure relief valve with special axial pneumatic actuator, or for information about how Crosby can provide you with a special valve designed to meet your needs, contact the Crosby Factory or your local Crosby Representative. Crosby Block Body Pressure Relief Valves With today’s process systems requiring greater and larger throughputs at ever increasing pressure, Crosby’s Block Body Pressure Relief Valves provide the solution to applications involving very high set and back pressures that exceed standard ranges. One single Crosby Block Body Pressure Relief Valve installation can handle the capacity of multiple API-526 standard valves with: ♦ ♦ ♦ ♦ Fewer potential leak paths Less down time and maintenance Fewer spare parts required Cost savings on inlet and outlet piping Design Details: ♦ ♦ ♦ ♦ ♦ ♦ ♦ Full nozzle design for maximum tightness Geometrically designed valve block body and bonnet for weight savings Dissimilar materials are used for guiding surfaces to eliminate galling Interference fitted inlet studs provided Available in orifice sizes from “D” through “T2” Materials of construction available for special process applications Available in Crosby Styles JOS, JBS and JLT valve designs For more information, contact the Factory or your local Crosby Representative. 58 Please refer to Warranty and Warnings on page 63. Crosby Styles JBS and JLT-JBS balanced bellows valves with supplementary back pressure balancing piston Styles JBS-BP and JLT-JBS-BP are a modification to the Crosby bellows pressure relief valve designed and tested in collaboration with engineers of one of the world's leading petroleum companies. This adaptation provides additional assurance of safe performance in the event of bellows failure on installations having discharge manifold systems where back pressures (constant or variable) are present. The Crosby bellows pressure relief valve (Styles JBS and JLT-JBS) was especially developed for service under back pressure conditions. The balanced area bellows counteracts back pressure effects. However, in case of a broken or ruptured bellows, the valve would perform in the manner of a standard valve without bellows. Introduction of the Supplementary Back Pressure Balancing Piston guarantees full performance characteristics of the valve until necessary replacement of the bellows can be made. This design, illustrated at the left, thus affords double protection. 5B Unless compensated for, the effects of back pressure may cause (1) a change in the opening pressure, (2) a decrease in valve capacity, and (3) valve performance to become unstable at higher back pressure. Use of the bellows valve with supplementary balancing piston maintains the balancing effect even after bellows failure and in such event would allow the valve to function in essentially the same manner as with the bellows intact. However, the bonnet of the valve must be vented in order to insure proper functioning of the valve. The vent also serves for a tell-tale in case of a ruptured or broken bellows. 17 Styles JBS-BP and JLT-JBS-BP Design The auxiliary balancing piston is incorporated in the basic bellows valve, modified to include the piston (5B) and the cylinder (17) which is part of the disc holder. The guiding clearances are held to a minimum and, in addition, grooves in the piston form a labyrinth seal to reduce flow between the piston and cylinder. Thus, in the event of a bellows failure, the leakage of fluid to atmosphere is kept to a minimum. Flanges and Flange Facing Dimensions of flanges conform to current ANSI standards. On full nozzle valve inlets, however, the thicknesses are greater than the minimum required by ANSI standards. Dimension X shown at right should be used to determine bolt length. Dimension X remains the same for raised face or ring joint flanges and is found on pages 14 through 42. All flange facings are spiral serrated finish or concentric serrated finish. Optional finishes are available. Drilling of inlet and outlet flange holes straddle the valve center line. Inlet and outlet flanges are spot faced on back for stud nuts. Center-to-face dimensions are subject to tolerance of ± 1/16" (1.5mm) for valves through 4" inlet size and ± 1/8" (3.17mm) for valves with inlet size larger than 4". In addition to standard raised face or ring joint flanges, tongue and groove or other flange facings are available as options. Please refer to Warranty and Warnings on page 63. 59 Crosby JBS and JLT-JBS Balanced Bellows Pressure Relief Valves for Sour Gas Service per NACE MR0175 Level 1 - For applications where compliance with NACE MR0175 is required for wetted parts in the primary (upstream) pressure zone of the pressure relief valve. Level 2 - For applications where compliance with NACE MR0175 is required for wetted parts in the primary (upstream) and secondary (downstream) pressure zones of the pressure relief valve. The stainless steel or Inconel bellows isolates the valve spring and other critical components above it from the process fluid. While the materials recommended for the Crosby Style JBS and JLT-JBS sour gas valves are suitable for average service conditions, optional materials are available to provide additional resistance to corrosion beyond the minimum requirements of the standard. Standard NACE Material Ref. No. Part Name 1 Body 2 3 4 5A 5B 5C 6 8 Nozzle Nozzle Ring Set Screw Disc Holder Bellows Top Flange Bellows Disc Insert Guide 9 10 Spindle Spring 11 12 Spring Washer Bonnet 13 14 15 16 20 21 22 23 24 25 Bonnet Stud Bonnet Nut Adjusting Bolt Adj. Bolt Nut Set Screw Gasket Guide Gasket Seal & Wire Seal Clip Type J Cap Cap Gasket Level 1 Carbon Steel Level 2 Carbon Steel SA-216 Gr. WCB SA-216 Gr. WCB 316 St.St. 316 St.St. 416 St.St. 316L St.St. 316L St.St. 316L St.St. 316 St.St. St.St. ASTM A 297 Gr. HE 416 St.St. Carbon Steel Steel Carbon Steel 316 St.St. 316 St.St. 316 St.St. 316L St.St. Inconel (Note 2) Inconel 316 St.St. St.St. ASTM A 297 Gr. HE 416 St.St. Carbon Steel Aluminum Metallized Steel Carbon Steel SA-216 Gr. WCB SA-216 Gr. WCB Alloy Steel Steel 416 St.St. Steel * * Lead & St.St. St.St. Steel * Note 1 Note 1 416 St.St. Steel * * Lead & St.St. St.St. Steel * Note: This vent must remain open on JBS construction 5B 5C 5A Style JBS (with bellows) Note: Shaded materials indicate variation from standard. *Organic Fiber Non-Asbestos Note 1 - Standard bolting material is furnished for NACE MR0175 Class III applications where bolting is not directly exposed to sour environments and is not buried, insulated, equipped with flange protectors, or otherwise denied direct atmospheric exposure. If Class I or II bolting is required, bolts will be ASME A193 Grade B7M HRC-22 maximum and nuts will be ASME A194 Class 2HM HRC-22 maximum. Note 2 - Top flange on D and E orifice bellows is 316 stainless steel. 60 Please refer to Warranty and Warnings on page 63. Crosby JOS and JLT-JOS Pressure Relief Valves for Sour Gas Service per NACE MR0175 Level 1 - For applications where compliance with NACE MR0175 is required for wetted parts in the primary (upstream) pressure zone of the pressure relief valve. Level 2 - For applications where compliance with NACE MR0175 is required for wetted parts in the primary (upstream) and secondary (downstream) pressure zones of the pressure relief valve. While the materials recommended for the Crosby Style JOS and JLT-JOS sour gas valves are suitable for average service conditions, optional materials are available to provide additional resistance to corrosion beyond the minimum requirements of the standard. Standard NACE Material 23 22 24 Ref. No. Part Name 1 Body 25 15 16 2 3 4 5 6 8 11 12 10 Nozzle Nozzle Ring Set Screw Disc Holder Disc Insert Guide 9 13 11 14 21 8 6 20 5 4 3 22 1 2 Style JOS 9 10 11 12 Spindle Spring Spring Washer Bonnet 13 14 15 16 20 21 22 23 24 25 Bonnet Stud Bonnet Nut Adjusting Bolt Adj. Bolt Nut Set Screw Gasket Guide Gasket Seal & Wire Seal Clip Type J Cap Cap Gasket Level 1 Carbon Steel Level 2 Carbon Steel SA-216 Gr. WCB SA-216 Gr. WCB 316 St.St. 316 St.St. 416 St.St. 316L St.St. 316 St.St. St.St. ASTM A 297 Gr. HE 416 St.St. Carbon Steel Steel Carbon Steel 316 St.St. 316 St.St. 316 St.St. 316L St.St. 316 St.St. St.St. ASTM A 297 Gr. HE 316 St.St. Inconel X750 316 St.St. Carbon Steel SA-216 Gr. WCB SA-216 Gr. WCB Alloy Steel Steel 416 St.St. Steel * * Lead & St.St. St.St. Steel * Note 1 Note 1 316 St.St. 316 St.St. * * Lead & St.St. St.St. Steel * Note: Shaded materials indicate variation from standard. *Organic Fiber Non-Asbestos Note 1 - Standard bolting material is furnished for NACE MR0175 Class III applications where bolting is not directly exposed to sour environments and is not buried, insulated, equipped with flange protectors, or otherwise denied direct atmospheric exposure. If Class I or II bolting is required, bolts will be ASME A193 Grade B7M HRC-22 maximum and nuts will be ASME A194 Class 2HM HRC-22 maximum. Please refer to Warranty and Warnings on page 63. 61 Pressure Relief Valve Seat Tightness Metal-to-Metal Seats and Soft Seats As system pressure approaches the valve set pressure, the differential force tending to hold the seats in contact is diminished. Consequently, to obtain an acceptable degree of tightness capability, the valve must be designed and built with a high level of quality. Tightness Standard The leakage rate in bubbles per minute shall not exceed the values indicated in Table I below. For soft seated valves there shall be no leakage for one minute (zero bubbles for one minute). Crosby pressure relief valves are carefully engineered and manufactured to provide those features essential for good valve performance and continuous long term protection. The inherent high degree of seat tightness found in Crosby pressure relief valves is possible due to the following design features: 1. Positive alignment of the seats through generous guiding and ball joints. 2. Minimum distortion as a result of full nozzle construction and thermally balanced disc design. 3. Excellent flatness and surface finish of the seating surfaces by precision machining and custom lapping. Cleanliness of the system and proper installation of the valve are also essential for good seat tightness. Definition Ambiguous terms such as "bubble tight," "drop tight," "zero leakage" and "commercial tightness" have been used in the past. Since these terms were used without uniform definition, they lacked true practical meaning. Now with the adoption of a standard that defines the terminology used to describe pressure relief devices (ASME Performance Test Code PTC25.3), and the adoption of a standard describing a method of determining seat tightness of relief valves (API Standard 527), there should exist a degree of uniformity throughout the industry. "Commercial" Seat Tightness Standard (API Standard 527) The following API Standard of "commercial" tightness has been adopted by industry and users in order to clarify testing methods and tightness standards for the sake of uniformity. It applies to pressure relief valves. The API Standard is as follows: Scope: This standard describes a method of determining seat tightness of pressure relief valves as covered in API Standard 527 Seat Tightness of Pressure Relief Valves. The maximum acceptable leakage rates are defined for commercial pressure relief valves with metal-to-metal and soft seats for set pressures up to 6000 psig (414 barg). If greater tightness is required, it can be supplied but must be specified on the purchase order or inquiry. See page 9 for Crosby soft seat pressure-temperature limits. Test Apparatus A typical test arrangement for determining seat tightness for pressure relief valves is shown in Fig.1. Leakage measurement shall be made with use of a 5/16 in. (7.93 mm) OD tubing with 0.035 in. (.88 mm) wall. The tube end shall be cut square and smooth. It shall be parallel to and 1/2 in. (127 mm) below the surface of the water. A clamp type seat leak apparatus is available from Crosby. Contact the factory. Table I Set Pressure psig (barg) 15-1000 (1.03-68.9) 1500(103.4) 2000(137.9) 2500(172.4) 3000(206.8) 4000(275.8) 5000(344.8) 6000(413.7) Effective Orifice Sizes 0.307 in.2 and Smaller Max. Approximate Bubbles Leakage Rate Per Per 24 Hours Minute Standard Standard Cubic Cubic Feet Meters 40 0.60 0.017 60 80 100 100 100 100 100 0.90 1.20 1.50 1.50 1.50 1.50 1.50 0.026 0.034 0.043 0.043 0.043 0.043 0.043 Effective Orifice Sizes Larger Than 0.307 in.2 Max. Approximate Bubbles Leakage Rate Per Per 24 Hours Minute Standard Standard Cubic Cubic Feet Meters 20 0.30 0.0085 30 40 50 60 80 100 100 Crosby Seat Tightness Standard Water Service Valves (Style JLT) Crosby pressure relief valves are checked for seat tightness by a quantitative seat leakage test. All of the test fluid passing through an assembled valve is collected and measured under the following test conditions: 1. The inlet pressure is adjusted to a test pressure which is 90% of the "Cold Differential Test Pressure." Valves set below 50 psig (3.44 barg) are tested at 5 psig (.34 barg) below the cold differential test pressure. 2. The seat leak pressure is maintained for a period of not less than ten minutes. Allowable Leak Rate The maximum allowable leakage rate should not exceed 10 cubic centimeters per hour per inch of diameter of nominal valve inlet size. For nominal valve sizes of 1 inch (25.4 mm) or less, the leakage rate shall not exceed 10 cubic centimeters per hour. For soft seated valves there shall be no leakage for one minute. NOTE - THE COVER PLATE SHOULD BE FITTED WITH A SUITABLE DEVICE TO RELIEVE BODY PRESSURE IN CASE OF ACCIDENTAL POPPING OF VALVE. With the valve mounted vertically, as shown in Fig. 1, the leakage rate in bubbles per minute shall be determined with pressure at the valve inlet held at 90 percent of the cold differential test pressure, except for valves set at 50 psig (3.44 barg) or below, in which case the pressure shall be held at 5 psig (.34 barg) below the cold differential test pressure. The test pressure shall be applied for a minimum of 1 minute for valves of inlet sizes through 2 in. (50.8 mm); 2 minutes for sizes 2-1/2, 3 and 4 in. (63.5, 76.2 and 101.6 mm); 5 minutes for sizes 6 in. and 8 in. (152.4 and 203.2 mm). Air at approximately atmospheric temperature shall be used as the pressure medium. TUBE 5/16" O.D. x 0.035" WALL (7.93 mm O.D. x .88 mm wall) COVER PLATE AIR RECEIVER Typical Test Arrangement Figure 1 Please refer to Warranty and Warnings on page 63. 0.013 0.017 0.021 0.026 0.034 0.043 0.043 Maximum Seat Leakage Rate Metal Seated Pressure Relief Valves Procedure 62 0.45 0.60 0.75 0.90 1.20 1.50 1.50 Ordering Information The primary purpose of Style JOS/JBS/JLT pressure relief valves is to protect lives and property. In order to select the proper valve for your application, please provide the information listed below. Details of the process fluid and conditions are especially important. If there is any doubt as to selection or application of valves or parts, please contact your local Crosby Sales Office or Representative. Ordering Information Quantity Nominal valve size (inlet x orifice x outlet) Valve style Inlet connection rating and facing Outlet connection rating and facing Service (liquid, gas or vapor) Set pressure (psig) Back pressure (psig) if any, and whether constant or variable Maximum service temperature (°F) Cap or lifting lever type Valve materials Seat material Code requirements Required capacity Accumulation (allowable overpressure) Molecular weight - vapor Specific gravity - gases and liquids Viscosity - liquids Example 5 4xLx6 JOS-45 600 RF 150 RF Air 800 psig Atmosphere Parts To order parts, the following information should be included: 1. Quantity 2. Part name, i.e., disc insert 3. Size, style and valve number 4. Assembly number (from valve nameplate) 5. Serial number (from valve nameplate) 6. Original purchase order number (if assembly number has been destroyed). Sample Nameplate (Figures shown are for illustrative purposes only.) Ambient 60F Type C Standard Metal-to-metal standard ASME Unfired Pressure Vessel Code Section VIII 45433 SCFM 10% 1.0 - Crosby provides special “fast response” delivery service of spare parts to satisfy unplanned parts requirements. Fast response delivery service can be initiated by contacting your local Crosby representative. Emergency delivery service is available direct from the factory, 24 hours a day, 7 days a week by calling (508) 384-3121. Springs with Washers To order springs with washers, in addition to the other information included for "Parts," the required valve set pressure must also be specified. If the spring is for a nonbellows valve, and there is a constant back pressure condition, that too should be specified. Also specify spring material and coating if other than standard. Replacement Valves To replace a valve in service, the assembly number, serial number, set pressure and previous order number should be specified. WARRANTY Crosby Valve & Gage Company, Crosby Valve and Engineering Company, Limited, Crosby Services International Ltd., Crosby Valve Pte. Ltd., Crosby Valve Ltd. or Crosby Valve Corporation (collectively “Crosby”) hereby warrant, for a period of one year from the date of shipment by Crosby, that its product or products (“Product”) shall be free from defects in workmanship and material. This Warranty shall extend only to original purchasers of Product (the “Purchaser”) and shall be exclusive of the effects of corrosion, erosion, normal wear and tear as well as defects due to improper application, handling, storage, installation or maintenance or where Purchaser has failed to comply with Crosby’s warnings. This Warranty also does not apply to any repairs, assembly or test work done on the Product by parties other than Crosby. Crosby does not warrant that its Product will perform in any specific or designated application. The use of replacement parts, components, products or services not manufactured by Crosby may, in the sole discretion of Crosby, void this Warranty. Under no circumstances shall Crosby be liable for special, incidental or consequential damages including, but not limited to, claims for economic loss. Moreover, in no event shall Crosby’s total liability exceed the original purchase price of the Product. CROSBY MAKES NO OTHER WARRANTY WITH RESPECT TO THE PRODUCT AND PURCHASER ACKNOWLEDGES THAT CROSBY EXPRESSLY DISCLAIMS ANY WARRANTY OR REPRESENTATION OF ANY KIND, EITHER EXPRESS OR IMPLIED, WITH RESPECT TO THE PERFORMANCE, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE, OR WITH RESPECT TO PATENT OR TRADEMARK INFRINGEMENT. Within this one year warranty period, any Product which Purchaser believes to be defective may be returned to Crosby after written notification to and authorization by Crosby. If Crosby determines that such Product is, in fact, defective, Crosby shall, at its option, either repair or replace the Product free of charge to the Purchaser. If the Product is not covered by this Warranty, any repair and shipping charges will be the responsibility of the Purchaser. These remedies are Purchaser’s sole and exclusive remedies. Should any portion of this Warranty be found to be invalid or unenforceable, such finding shall not affect the other terms of the Warranty which shall be construed as if such portion had never been contained herein. WARNING The Product is a safety related component intended for use in critical applications. The improper application, installation or maintenance of the Product or the use of parts or components not manufactured by Crosby may result in a failure of the Product. The advice of a qualified engineer should be sought prior to any use of the Product. Any installation, maintenance, adjustment, repair or test performed on the Product must be done in accordance with the requirements of all applicable Codes and Standards. The information, specifications and technical data (the “Specifications”) contained in this document are subject to change without notice. Crosby does not warrant that the Specifications are current and assumes no responsibility for the use or misuse thereof. The Purchaser should verify that there have been no changes to the Specifications prior to use. WARNING: The information contained in this catalog is for informational purposes only. See also Crosby’s Engineering Handbook and computer program, CROSBY-SIZE. The actual selection of valve products is dependent upon numerous factors and should be made only after consultation with applicable Crosby personnel. Crosby assumes no responsibility for the actual selection of such products and hereby expressly disclaims liability for any and all claims and damages which may result from the use or application of this information or from any consultation with Crosby personnel. Please refer to Warranty and Warnings on page 63. 63 Crosby Styles JOS, JBS and JLT ® Catalog No. 310 Effective: April 1995 Corporate Headquarters and Operations Center P.O. Box 944 Stafford, Texas 77497, USA Telephone: (281) 274-4400, Fax: (281) 240-1800 Operations Centers 43 Kendrick Street Wrentham, Massachusetts 02093, USA Telephone: (508) 384-3121, Fax: (508) 384-8675 Corrie Way, Bredbury Industrial Estate Stockport, Cheshire SK6 2ST, UK Telephone: 44-161-494-5363, Fax: 44-161-494-5672 Crosby Road Market Harborough, Leics LE16 9EE, UK Telephone: 44-1858-467281, Fax: 44-1858-434728 No. 45, Tuas Avenue 9 Jurong, Singapore Telephone: 65-861-1655, Fax: 65-861-8310 149 Gul Circle Singapore 629605 Telephone: 65-862-2177, Fax: 65-862-1778 © 1999 Anderson Greenwood / Crosby Printed in USA