Heavy Duty Safety Switches SELECTION r Horsepower Ratings Outdoor — Type 3R Indoor — Type 1 System Ampere Rating Catalog Number List Price $ Ship Wt.* Std. Pkg. 600V AC 480V AC 1 Phase, 2 Wire 3 Phase, 3 Wire 1 Phase, 2 Wire 3 Phase, 3 Wire Std. Std. Std. Std. Catalog Number List Price $ Ship Wt." Std. Pkg. 585.00 680.00 1085.00 3565.00 7030.00 15 20 27 152 155 3 5 10 — — 30 50 50 Max. Max. Max. Max. 250 Volt DC 600 Volt DC 600 Volt Fusible^ 480 Volt AC/600 Volt AC/600 Volt DC 2-Pole, 2-Fuse® \\ 30 60 100 400 600 \\\ 30 60 100 200 400 600 800 800 1200 1200 HF261 HF262 HF263 HF265 HF266 345.00 410.00 768.00 2915.00 4990.00 15 20 26 149 150 HF261R HF262R HF263R HF265R HF266R 356.00 424.00 792.00 1143.00 3005.00 5145.00 9270.00 9270.00 11710.00 11710.00 14 19 24 48 154 157 225 380 265 383 HF361R HF362R HF363R HF364R HF365R HF366R FR357L HF367R® FR358L HF368R® 603.00 704.00 1117.00 1501.00 3675.00 7300.00 11240.00 11240.00 13830.00 13830.00 15 20 25 49 157 161 235 382 270 385 3 5 10 25 — — — _ — TA 20 30 50 — — — — — — — 14 19 25 49 158 161 382 385 HF361NR HF362NR HF363NR HF364NR HF365NR HF366NR HF367NR® HF368NR® 663.00 764.00 1233.00 1617.00 3983.00 7572.00 11765.00 2210.00 15 20 26 50 162 165 386 388 3 5 10 25 — — _ 1% 20 30 50 — — _ — — TA 20 — — — — — 3-Pole, 3-Fuse r mi Wf 3 10 15 50 50 10 25 40 — — — — — — — — — — — — 5 10 20 40 50 15 30 50 50 50 480 Volt AC/600 Volt AC/250 Volt DC® HF361 HF362 HF363 HF364 HF365 HF366 F357L HF367® F358L HF368® 5 15 25 50 100 150 — 200 — 200 3-Pole, 3-Fuse and Solid Neutral 30 60 100 200 400 600 800 1200 — — — — — HF361N HF362N HF363N HF364N HF365N HF366N HF367IM® HF368N® 416.00 484.00 908.00 1259.00 3313.00 5417.00 9795.00 12234.00 15 30 60 125 250 400 — 500 — 500 3 10 15 30 — — — _ — 10 25 40 50 — — — — — — — TA 15 30 60 125 200 — 250 — 250 20 50 75 150 350 500 — 500 — 500 5 10 20 40 50 — — _ — — 25 25 50 — — — _ — — — 480 Volt AC/600 Volt AC/250 Volt DC® 5 15 25 50 100 150 150 150 15 30 60 125 250 400 400 400 3 10 15 30 — — _ 10 25 40 50 — — _ — — TA 15 30 60 125 200 200 200 20 50 75 150 350 500 500 500 _ 5 10 20 40 50 _ _ 25 25 50 — _ _ — — 600 Volt Fusible® (For 2-Pole Applications use outside poles of 3-Pole Switches) 2-Pole, 2-Fuse® \\ 480 Volt AC/600 Volt AC/600 Volt DC Type 4/4X Stainless 30 60 100 400 600 Type 12 Industrial® 1530.00 1715.00 3295.00 9465.00 13990.00 15 20 27 153 156 HF261J HF262J HF263J HF265J HF266J HF361S 1581.00 HF362S 1768.00 HF363S 3398.00 HF364S 4825.00 HF365S 9760.00 HF366S 13805.00 F357SSL 19815.00 HF367S® 19815.00 13 20 25 49 158 161 400 380 HF361J HF362J HF363J HF364J HF365J HF366J F357HL HF367J® HF281S HF262S HF263S HF265S HF266S 570.00 590.00 935.00 3295.00 5625.00 15 20 27 155 156 3 5 10 TA 20 30 50 50 585.00 610.00 966.00 1545.00 3395.00 5800.00 10445.00 10445.00 14 20 25 49 160 161 395 380 _ — _ — — — — _ — _ — — _ _ 5 15 25 50 100 150 _ 15 30 60 125 250 400 _ — — 200 500 — \\\ r 3 10 15 50 50 10 25 40 — — 5 10 20 40 50 15 30 50 50 50 480 Volt AC/600 Volt AC/250 Volt DCQ 3-Pole, 3-Fuse 30 60 100 200 400 600 800 800 — * In pounds (Ibs). ® 60-200A 3-Pole switches are also rated 600V DC. © Consult sales office for availability. ® Use 3-Pole switch for 200A applications. Discount Schedule A ® Dual horsepower ratings: Std.- applies when non-time delay fuses are installed. Max.- applies when timedelay fuses are installed. © Suitable for use as service entrance equipment. _ 20 50 75 150 350 500 _ 5 10 20 40 50 _ _ _ _ _ _ _ TA 15 30 60 125 200 — 250 500 — — __ _ — _ _ _ _ _ _ — _ © Also rated Type 3S/3R. Siemens Electrical Products SPEEDFAX 2000 25 25 50 _ _ _ General and Heavy Duty Features PRODUCT OVERVIEW Siemens Type VBII Safety Switch Application f i . iS ^K £g """ General Duty Switches General Duty Switches are intended for applications where reliable performance and continuity of service are needed, but where duty requirements are not severe and usual service conditions prevail. 'These switches are intended for use primarily with supply circuits rated 240V AC or less where the available fault current Is less than 100.000A when used with Class R or T fuses or 10.OOOA max. when used with Class H fuses.) Heavy Duty Switches Heavy Duty Switches are intended for use in applications where: 1. Rugged construction, reliable performance, continuity of service and ease of maintenance are emphasized, or 2. Available fault currents higher than 10.000A are likely to be encountered, such as in manufacturing plants, mass production industries, and commercial, institutional and other large buildings served by network systems or transformers of higher capacities. 3. System voltage is 600V AC or DC Max. 4. A Type 12 or 4 / 4X enclosure is required. Short Circuit Withstand Ratings General Duty Switches Suitable for use on systems capable of delivering not more than 100,000 RMS symmetrical amperes of fault current when Class R fuses are installed. Also rated 100,000 AC max. In 200-600A ratings with Class J and T fuses. Heavy Duty Switches Suitable for use on systems capable of delivering not more than 200,000 RMS symmetrical amperes of fault current when Class J or R fuses are installed except the 800 and 1200A switches, which are suitable for use on circuits capable of delivering not more than 200,000 RMS symmetrical amperes of fault current when Class L fuses are installed. 100-1200A switches with Class T fuses and field adapter kit are also 200,000 RMS symmetrical rated. Fuses General Duty Switches Fusible switches will accept the following UL class fuses: Class H Class K Class R - Class R fuse clip rejecter kits are required. Class T - 200-600A switches (200A switches require field adapter kit). Heavy Duty Switches Fusible switches will accept the following UL class fuses: Class H Class K Class R - Class R fuse clip rejecter kits are required. Class J - 240 and 600V switches. All switches are field convertible. Class L - 800 and 1200A switches only. Class T -100-1200A switches (100 and 200A switches require an adapter kit). CD30A general duty has fuse clips constructed of spring type copper. Siemens Electrical Products SPEEDFAX 2000 Groundable Neutrals o General & Heavy Duty Switches Switches designed for use on systems requiring neutrals have groundable neutral blocks. Padlocks General & Heavy Duty Switches Padlockable cover latch and multiple padlock provisions on handle. Cover Interlocks General Duty Switches Defeatable-cover interlocks on Type 1 switches and 60-600A Type 3R switches prevent the switch door from being opened when in the "ON" position. Heavy Duty Switches Defeatable dual cover interlocks are standard on all heavy duty switches. Prevents cover from being opened when switch is in the "ON" position and prevents switch from being turned "ON" when door is opened. o Underwriters' Laboratories, Inc. Listed by UL under file #E4776 as enclosed switches and also suitable for use as service equipment. NEMA Specifications Meets NEMA standard KS-1-1990 for type GD and HD switches. Federal Specifications Meets federal specification W-S-865C for heavy duty switches. (Type ND for general duty and Type HD for heavy duty). Type 1 switches - general purpose enclosures (Type 1). Type 3R switches - rainproof enclosures (Type 3R). Type 4 / 4X switches - special purpose enclosures (Type 4 / 4X). Type 12 switches - special purpose enclosures (Type 12). o Catalog Numbering System_______ PRODUCT OVERVIEW Type VBII Safety Switch Catalog Numbering System N H R CU L Switch Type Special Applications With: CH CJ CR CU Crouse-Hinds Receptacle Factory J Fuse Spacings Class R Clips Installed Factory-Installed Copper Wire Grips G = Factory-Installed Ground Bar PN = Pyle-National Receptacle W = Viewing Window L = General Duty 10k AlCMax. (Plug Fused & 60A Max Non-Fused) G = Gen. Duty H = Heavy Duty Fused or Non-Fused = = = = Enclosure Type F = Fused NF = Non-Fused Omit R S J = Type = Type = Type = Type 1, Indoor 3R, Outdoor 4 / 4X, Stainless Steel 12, Industrial Number of Poles 1 = 1 2 = 2 3 = 3 With or Without Neutral Omit = Less Neutral N = With Neutral Voltage Amperes 1 = 120V or 120/2 40V 2 = 240V 6 = 600V 1 2 3 4 5 6 7 8 = 30A = 60A = 100A = 200A = 400A = 600A = 800A = 1 200A Type VBII Accessories Catalog Numbering System H Switch Type H = Heavy Duty G = General Duty A1 A2 A3 CL = = = = G G2 LC N N2 P R T = = = = = = = = Auxiliary Switch 1/NO and 1/NC Auxiliary Switch 2/NO and 2/NC Auxiliary Switch Low Current Compression Lug Barrier/ Mounting Kit Ground Lug Kit Insulated Ground Lug Kit Copper Lug Kit Neutral 200% Neutral Fuse Puller Kit Class R - Fuse Clip Kit Class T - Fuse Kit F* e} 4 Amperes 1 2 12 3 23 123 1234 4 56 5678 78 =30A =60A = 30/60A = 100A =60/100A = 30/60/1OOA = 30/60/100/200A = 200A = 400/600A = 400/600/800/1200A = 800/1200A Maximum Voltage 2 = 240V Max 6 = 600V Max Note: Catalog numbers systems above do not apply to Vacu-Break and double throw switches & accessories. Siemens Electrical Products SPEEDFAX 2000