Name of the Group
Drugs & Medicines
General Surgical Consumable (including Sutures &
Dressing Material)
Lab Consumable & non consumable
General Items, Stationery & Linen (Consumable
& Non-Consumable)
Anesthesia (Consumable & Non-Consumable)
Medicine (Consumable & Non-Consumable)
Pediatrics (Consumable & Non-Consumable)
Gynae (Consumable & Non-Consumable)
Radiology (Consumable & Non-Consumable)
Medical Gases
EMD
(In Rs.)
50,000.00
50,000.00
50,000.00
50,000.00
50,000.00
50,000.00
50,000.00
50,000.00
25,000.00
25,000.00
The tender form can be obtained from Procurement Branch, SDDMSC, Dabri, Delhi w.e.f. 05.10.2009
upto 04.11.2009 on any working day between 10.00 AM to 1.00 PM on payment of Rs.500/- in the form of DD in
favour of “Medical Superintendent, SDDMSC, Dabri, Delhi”.
The Tender Notice is also available on website of Govt. of Delhi, www. delhi govt.nic.in and can also
be downloaded. In case of downloading, tenderer will have to deposit a draft of Rs.500/- alongwith tender form
by Demand Draft drawn in favour of Medical Superintendent, SDDMSC, Dabri, Delhi. For obtaining the tender
form by post, the tenderer should apply with a self addressed envelope size 35cm x 25cm along with demand
draft of Rs. 100/- as postal charges etc. in addition to the tender cost of Rs. 500/-.
The tender document complete in all respect along with the Earnest Money in the form of Fixed Deposit
Receipt (for 2 years) for Rs. 50,000/- for Group I to Group VIII and Rs. 25,000/- for Group IX to Group X in
favour of Medical Superintendent, SDDMSC, Dabri, Delhi should be put in a tender box placed in the Office of
Medical Supdt, SDDMSC, Dabri, Delhi, Delhi by 2.00PM on 04.11.2009. Tender received through post or after
due date and time will not be accepted.
The tender process involves of 02-stage scrutiny - technical bid and price bid. The technical bid will be
opened on 04.11.2009 at 2.30 PM in presence of tenderer or their authorized representative who choose to be
present on the occasion. Price bid of technically qualified tender will be opened later, for which date, time &
venue will be intimated to technically qualified tenderer separately. The tender will be valid for 01 (one) year
from the date of issue of Rate Contract; however it can be extended further on mutual consent and satisfactory
performance by the agency.
Medical Supdt., SDDMSC, Dabri, Delhi has the full and exclusive right to accept or reject any or all the
tenders without assigning any reasons and also to cancel the supply order at any time.
MEDICAL SUPERINTENDENT
SDDMSC, DABRI, DELHI
1
GOVT. OF NCT OF DELHI
OFFICE OF THE MEDICAL SUPERINTENDENT
SHRI DADA DEV MATRI AVUM SHISHU CHIKITSALAYA, DABRI, DELHI-110 045
Issued to M/s……………………………..…..
Cost of the tender Rs.500/(Non-refundable)
Tender due on : 04.11.2009
For Procurement of items under Group No._____
TENDER FORM
Sealed tenders are invited from licensed manufacturer/supplier having Delhi Sales Tax Registration
Number/TIN for entering into running Rate Contract for supply of various consumable and non-consumable
items to SDDMSC, Dabri, Delhi, for a period of one year from the date of issue of Rate Contract which may be
extended further till the next rate contracts are awarded.
The tender form can be obtained from Procurement Branch, SDDMSC, Dabri, Delhi, w.e.f. 05.10.2009
upto 04.11.2009 on any working day between 10.00 AM to 1.00 PM on payment of Rs.500/- in the form of DD
in favour of “Medical Superintendent, SDDMSC, Dabri, Delhi”. The Tender document is also available on
website of Govt. of Delhi, www.delhi govt.nic.in and can also be downloaded. In case of downloaded tender,
tenderer will have to deposit a draft of Rs.500/- along with tender document in the form of Demand Draft drawn
in favour of “Medical Superintendent, SDDMSC, Dabri, Delhi”. For obtaining the tender document by post, the
tenderer should apply with a self addressed envelop size 35cm x 25cm along with demand draft of Rs. 100/- as
postal charges etc. in addition to the tender cost of Rs. 500/-. The tender document complete in all respect
alongwith the Earnest Money in the form of Fixed Deposit Receipt (for 2 years) for Rs. 50,000/- for Group I to
Group VII and Rs. 25,000/- for Group XI to Group X in favour of “Medical Superintendent, SDDMSC, Dabri,
Delhi” should be dropped in tender box placed in the Office of Medical Supdt, SDDMSC, Dabri, Delhi, by 2.00
PM on 04.11.2009. Tender received through post or after due date and time will not be accepted.
The tender process involves of 02-stage scrutiny - technical bid and price bid. The technical bid will be
opened on 04.11.2009 at 2.30 PM in presence of tenderer or their authorized representative who choose to be
present on the occasion. Price bid of technically qualified tender will be opened later, for which date, time &
venue will be intimated to the technically qualified tenderer separately. The tender will be valid for 01 (one) year
from the date of issue of Rate Contract; however it can be extended further on mutual consent and satisfactory
performance by the agency.
Medical Supdt., SDDMSC, Dabri, Delhi has the full and exclusive right to accept or reject any or all
the tenders without assigning any reasons and also to cancel the supply order at any time. The following terms
and conditions should be read carefully and complied with before submitting the tender.
1)
TERMS AND CONDITIONS
Tenders should be prepared in two separate envelopes Technical bid and Price bid.
a) Technical Bid containing original Performa for SDDMSC Open Tender dully filled in and
signed, Earnest Money Deposit and copies of required documents. Irrelevant/uncalled document
need not to be enclosed with the Technical Bid.
b) Price Bid containing prescribed schedule to quote the rate duly filled in and signed without overwriting, neatly written.
Further these two sealed envelopes of Technical Bid and Price Bid must be kept in single envelope
super scribed as SDDMSC OPEN TENDER FOR SUPPLY OF ITEMS UNDER GROUP…….., Due Date and
Name & address of tenderer. PLEASE NOTE THAT PRICE SHOULD NOT BE INDICATED IN TECHNICAL
BID, OTHERWISE THE BID WILL BE DISQUALIFIED.
2)
Tender should be preferably typed and the rates be quoted in words AS WELL AS IN FIGURE without
any overwriting or erasing which will render the tender of that particular item invalid.
3)
The tenderer is bound to submit an undertaking as per Performa attached on non-judicial stamp paper
of Rs. 100/-(one hundred) only.
4)
Covering letter should clearly indicate the list of the items quoted and enclosures.
5)
Only one model/brand to be quoted against each item. If more than one model/brand is quoted, the
item will not be considered for technical/Price Evaluation.
6)
Each paper of the tender must be numbered and signed by the tenderer with the seal of the firm and all
photocopies of original documents must be attested by Gazetted Officer/Notary/.
7)
The rates quoted should be exclusive of VAT. The rates of Sales Tax (State & Central)
chargeable may however be given separately.
2
8)
Each tender must be accompanied by a fixed deposit receipt valid for two years forRs.50,000/- (Rupees
Fifty Thousand) Only for Group I to Group VIII and Rs. 25,000/- for Group IX to Group X as an Earnest
Money Deposit/Security deposit pledged in favour of Medical Supdt., SDDMSC, Dabri, Delhi, payable at
New Delhi. No cheques/Postal Orders/Money Order/ Cash Payment will be accepted. Govt.
undertakings and Small Scale Industries are exempted from submitting the Earnest Money. However, if
the rate contract holding firm fails or neglects to observe or perform any of his obligations under the
contract, it shall be lawful for the purchaser to forfeit the earnest money deposited.
Earnest Money deposit of the successful tenderer will be kept as the security deposit against the
tender, which will be released two months after the successful completion of the Rate Contract.
9)
10)
11)
12)
13)
14)
15)
16)
17)
18)
19)
20)
21)
22)
23)
24)
The tenderers must attach Photostat copy of Sales Tax Registration/TIN Certificate duly attested by any
Gazetted Officer/Notary/Self. Failure to submit the STRC/TIN will render the tender invalid
automatically.
The tenderers must attach self attested Photostat copy of PAN of the firm (in case of partnership/public
limited co.) or individual PAN (in case of sole proprietorship along with certificate in this regard).
In case of Drugs/Medicine, the tender should quote only those items for which the manufacturer is
having valid WHO GMP Certificate /Revised Scheduled M Certificate and attested copy of the same
issued by the drug controller of the concerned State indicating the date of validity /current valid
certificate along with a list of product registered should also be submitted.
Pharmacopeia specification: IP/BP/USP etc. should be clearly mentioned against each drug
/constituent of the drug quoted as per the provision of the Drugs & Cosmetic Act.
In case of equipment, catalogues with detailed specifications must be submitted with the technical bid.
However at the time of approval of tender the technical committee can ask for samples / demonstration.
Samples will be received in the respective Stores.
In case of items without catalogue, sample should be submitted in the concerned store By
04.11.2009. No sample will be received after 04.11.2009.
Every sample should be tagged with the slip mentioning the name of the firm, Group .No. & Sl.No. of
the tender and name of the item. After finalization of the tender the firm must remove the unapproved
item within 15 days, failing which the sample will be disposed off without further reference to the firm.
Approved samples will be kept in the store concerned till the validity of the rate contract.
The firm/tenderer should not be blacklisted in the past by any Govt./Pvt. Institution.
Delivery period: The supplies have to be made within 30 days (for indigenous item) and 90 days (for
imported items) from the date of issue of the supply order, failing which the order is likely to be
cancelled. The time or/and date of delivery of equipment stipulated in supply order shall be deemed to
be essence of contract and delivery must be completed in stipulated period. However in exceptional
circumstances and at written request before expiry of delivery period, extension of date of supply can
be considered for further 15 days of indigenous items and 30 days for imported items. Grant of
extension of supply period is at the sole discretion of Medical Superintendent. The delivery of goods
can be accepted after expiry of delivery/extended period with penalty of 5% of the value of order for
every delayed week or part of week, subject to maximum of 10% depending on the requirement of the
hospital.
The firm will be bound to supply the equipment/store with in stipulated /extended period, failing which
the supply order is likely to be cancelled and EMD/Security Deposit will be forfeited and/or firm may be
blacklisted.
Store shall be marked with the words in CAPITAL AND BOLD LETTERS ‘NOT FOR SALE – FOR
SUPPLY TO GOVT.OF NCT OF DELHI’.
The store supplied should have adequate expiry period and should not passed 1/6th of self life.
The hospital has right to send the sample(s) from consignment received for testing. If the product is
found not of standard quality, the total cost of the test will be recovered from the supplier. The supplier
will have to replace the entire consignment irrespective of the fact that part of the stores supplied may
have been consumed. All rejected store shall in any event remain and will always be at the risk of the
supplier.
In case, tenderer is the sole distributor of a particular item he should submit authority letter in support
of the same from the actual manufacturer. In case tenderer is selling agent of a particular item he
should submit an authority letter in support of the same from the actual manufacturer/sole distributor
concerned. Failure to submit the authority letter of a particular item may render the tender invalid for
that particular item. If the Principal Manufacturer/sole distributor withdraws its distribution ship from the
tenderer during validity period of approved rates, Medical Superintendent has full right to cancel the
eligibility of tenderer.
The tenderers are bound to supply the store during the validity of tender at the approved rates. The
validity of the tender will be for the period of one year from the date of issue of Rate Contract. However,
3
25)
26)
27)
28)
29)
30)
31)
32)
33)
34)
35)
36)
37)
38)
the contract can be extended further up to another 01 year subject to satisfactory performance of the
firm and on mutual consent.
Tender form is non-transferable.
The payment will be made after the receipt of the item and completion of all codal formalities. No
advance payment will be made.
If `D' form is required, it will be provided by the concerned office subject to the production of necessary
documents thereof.
While quoting rates S.No. of the tender list must be indicated and rates should be quoted in the same
S.No./order as given in the tender list
The price quoted should be in Indian currency only.
The price quoted should not exceed the MRP/prevailing market price/rate quoted in another Hospital
under Govt. of NCT of Delhi in the same financial year.
In case of equipments / machines having cost below Rs.2.0 Lacs, the tenderer will give comprehensive
guarantee for 24 months. He will maintain the equipment / machine during this period and replace
spare parts at free of cost, if necessary. The tenderer should be in position to provide the AMC
services, spare parts and consumable for 3 years, after 2yrs guarantee. Repair of equipment/ machine
is to be carried in the hospital premises where it is installed. In case the equipment / machine is to be
shifted to the manufacturer workshop for repair, to & fro transport charges are to be born by the
tenderer. The Tenderer shall ensure that down time is minimum & shall have to supply standby unit in
case of undue delay in public interest.
However in case of equipment costing more than Rs.2.0 lacs each, the tender will submit
comprehensive guarantee/warranty from the manufacturer for a period of 60 months including spares.
For the next 60 months the firm shall provide free service and shall charge for the spares, if any.
The firm should submit bank guarantee of 10% of the cost of the equipment costing more than Rs.2.00
lacs (valid for 05 years) and indemnifying the hospital against all losses incurred by the hospital during
the guarantee period.
Instruments and other items with certification will be preferred. Attested copies of certification like
CE/FDA/BSI etc. should also be submitted wherever necessary.
Post tender negotiation will not be allowed.
The decision of Medical Superintendent regarding approval of sample/item shall be final.
The tenderers must attach a soft copy of technical Bid alongwith the hard copy of the technical bid in
form of CD.
The courts of Delhi shall alone have jurisdiction to decide any dispute arising out of or in
respect of the contract.
MEDICAL SUPERINTENDENT
SDDMSC, DABRI, NEW DELHI
4
To be enclosed with technical bid
UNDERTAKING
(On non-judicial stamp paper of Rs.100/-)
Open Tender for Supply of Items under Group____________
Date of opening_______________
The undersigned undertake with Medical Superintendent, SDDMSC, Dabri, Delhi to declare and accepts as
follows:
1.
It is certified that I/We…………. s/o…………… r/o……………. am sole proprietor/partner/director of the
firm M/s…………………………..
2.
The undersigned declare that I/We have gone through the terms & conditions mentioned for the above
and undertake to comply with them. The rates quoted by me/us are valid and binding on me/us for
acceptance for the period of one year from the date of issue of Rate Contract and in extended period, if
any.
3.
I/we undersigned hereby bind myself/ourselves to the Medical Superintendent, SDDMSC, Dabri, Delhi
to supply the items for SDDMSC, Dabri , Delhi for or on behalf of the Lt. Governor of Delhi during the
period of contract. The exclusive showing the rates quoted by me/us for the items tendered for are
specified against each.
4.
The article shall be of the best quality and kind as per requirement of the institution. The decision of the
Medical Superintendent, SDDMSC, Dabri, Delhi (herein after called the said officer) as regards to the
quality and kind of article shall be final and binding on me/us.
5.
Earnest Money deposited by me/us viz. in the form of FDR for 02 years, pledged in favour of Medical
Superintendent SDDMSC, Dabri, Delhi is enclosed herewith and shall remain in custody of the Medical
Superintendent, SDDMSC, Dabri, Delhi till the successful completion of the rate contract as
security/performance deposit.
6.
If I/We fail to supply the article within the stipulated time as per terms & conditions of the tender, the
Medical Superintendent, SDDMSC, Dabri will have full right to forfeit the security deposited by me/us,
cancellation of contract and/or blacklisting of firm.
7.
If any items/articles supplied found of inferior quality it shall be replaced by me/us immediately failing
which I/we shall be liable for forfeiture of Security Deposit deposited, cancellation of contract and/or
blacklisting of firm.
8.
There is no vigilance case pending against the firm / supplier.
9.
I/We hereby certify that my/our firm has not been blacklisted in the past by any Govt. /Pvt. Institution.
10.
I hereby undertake to supply the items during the validity of the tender as per direction
given in supply order within the stipulated period.
11.
In case of equipment costing less than Rs.2 Lacs I/We will provide comprehensive guarantee/warranty
for 24 months and will provide free service for next 3 years and will charge only for spares. However, in
case of equipments/ machines costing more than Rs.2.00 Lacs, I/We undertake to provide
comprehensive guaranty/warranty from the manufacturer for a period of 60 months including spares.
After 60 months, I/we will provide maintenance free of cost for another 60 months and will charge only
for spare parts and accessories. I/We undertake to give post replacement guarantee/warranty of the
parts replaced for minimum 06 months for the period beyond 60 months.
12.
In case of equipment costing more than Rs.2.00 Lacs, I/We should submit a bank guaranty of 10% of
the cost of the equipment indemnifying the hospital against all losses incurred by the hospital during the
guarantee period.
13.
The Medical Superintendent, SDDMSC, Dabri, Delhi has the right to accept or reject any or all the
tenders without assigning any reason.
14.
I/We agree to accept the amount of the bill to be paid by the purchaser after completion of all codal
formalities and should any amount of the bill found by the audit office or Govt. of Delhi to have been
over-paid, the amount so found shall be refunded by me/us.
15.
I/we understand all the terms & conditions of rate contract and bind myself/ourselves to abide by them.
16.
It is certified that the rate quoted by me are not higher than the M.R.P/prevailing market rate/rate
quoted in other hospital under GNCTD in the same financial year. If it is found false, the firm may be
penalized or blacklisted.
17.
Certified that I/We have paid the Income Tax as assessed for the period ending……………….
18.
Certified that I/We have paid the Sales Tax as assessed for the period ending on……………… and
proof thereof is enclosed.
19.
I shall also be responsible to pay all taxes as applicable to the Govt. like; Sales tax/VAT, Income tax
etc.
SIGNATURE OF THE TENDERER
WITH STAMP
5
GOVT. OF NCT OF DELHI
OFFICE OF THE MEDICAL SUPERINTENDENT
SHRI DADA DEV MATRI AVUM SHISHU CHIKITSALAYA, DABRI, DELHI-110 045
8.
Form SDDMSC, Dabri Annual Open Tender 2009-10
Name of the tenderer/firm:
Full postal address:
Telephone No. & Fax No. :
Whether the tendering firm is manufacturer of items or supplier
Name/Address of the Proprietor:
Status of the Proprietor (Sole/Partnership/Public Ltd.) :
Name of person who are responsible for conduct of business:
Sl. No. Name Father’s/Husband’s Name Age Residential Address
Name of Govt. Hospitals/institutions to which the tenderer already supplied the items
9.
Has the tenderer ever been black listed by any Govt. agency? If yes, give details
10.
Are any cases pending in the court related to any supplies? If yes, give details (attach separate sheet)
11.
Registration No. of Sales Tax/TIN with copy of registration no
12.
Whether Income Tax has been paid, if so Indicate the last period of assessment
13.
Does the firm have the adequate facilities to check the quality?
14.
Tenderer should enclose the required documents as per check list enclosed here with
1.
2.
3.
4.
5.
6.
7.
I, ______________________________________________Prop./Partner/Director of M/s___________
_______________________________________________ hereby declare that the information given in this
form is true & correct to the best of my knowledge & belief.
I offer to supply the items mentioned in the schedule (enclosed in price bid) at the rates quoted therein. I agree
to hold this offer for one year after finalization of rate contract.
Yours faithfully
Dated: Signature
Name of tenderer………………….
Address…………………………….
……………………………..
……………………………..
WARNING: - Subsequently, if information furnished in this form is found incorrect, the tender will be rejected
and further tenderer will be black listed.
6
To be enclosed in Technical Bid
GOVT. OF NCT OF DELHI
OFFICE OF THE MEDICAL SUPERINTENDENT
SHRI DADA DEV MATRI AVUM SHISHU CHIKITSALAYA, DABRI, DELHI-110 045
NAME OF FIRM
TENDER FOR SUPPLY OF ITEMS UNDER GROUP…………
LIST OF ITEMS QUOTED:S.No.
S.No.as per
tender
Name of items
Make/
Model
Indian or
Imported
Sample
(Yes/No)
Catalogue
Yes/No
If required separate sheet may be appended.
Signature_____________________
Name of tenderer_______________
7
To be put in separate envelope superscribed “Price Bid”
GOVT. OF NCT OF DELHI
OFFICE OF THE MEDICAL SUPERINTENDENT
SHRI DADA DEV MATRI AVUM SHISHU CHIKITSALAYA, DABRI, DELHI-110 045
Schedule to quote rates
NAME OF FIRM_______________________
TENDER FOR SUPPLY OF ITEMS UNDER GROUP…………
S.No.
S.No.
as per
tender
Name of items
Make/
Model
Rate per unit
(In Rs.)
Figures
Words
Tax
Yes (%)/No
Signature _____________________
Name of tenderer _______________
Note: 1. Rate quoted should be exclusive of VAT. Sales Tax Chargeable if any may be given separately.
2. Rate should be according to unit asked for.
3. Plea of clerical error, typographic error etc. would not be accepted.
4. In no case the rate quoted should be higher than the M.R.P. of that item.
8
GOVT. OF NCT OF DELHI
OFFICE OF THE MEDICAL SUPERINTENDENT
SHRI DADA DEV MATRI AVUM SHISHU CHIKITSALAYA, DABRI, DELHI-110 045
Check list of documents to be submitted in the technical bid:
S.N.
Name of the Document
Yes/No
1
2
3
4
Tender Application Form in original
Undertaking on Non-Judicial Stamp Paper of Rs.100/Duly filled & signed form for SDDMSC, Dabri Open Tender
Earnest Money Deposit (EMD) for Rs. 50,000/- for Group I to
Group VIII and Rs. 25,000/- for Group IX to Group X in the form
of FDR valid for 02 years, pledged in favour of “Medical
Superintendent, SDDMSC, Dabri, Delhi”.
Sales Tax Registration Certificate (STRC)/TIN ,
DVAT Return
PAN No. Return
Authority letter from manufacturer/Distributor
Drug License, if applicable
Yes/No
Yes/No
Yes/No
Yes/No
5
6
7
8
Page No
Yes/No
Yes/No
Yes/No
Yes/No
Note: All above documents are mandatory for technical bid. Irrelevant/uncalled document need not to
be enclosed with the technical bid.
Signature of tenderer with seal
9
Tender Group No. I
Tender for Medicines/Drugs
(CPA Medicines/Drugs shall be procured only when CPA fail to make the supply)
S.No.
Name of Item
1
Antacid gel with MgOH+ALCL3+Activated, 200ml, Francosil MPS
2
Antispasmodic Drops Each ml contains Dicyclomine HCl IP10mg.,Activated
Diamethacone IP , 40mg-10ml Bottle
3
Betamethosone + Gentamycin + Tolnaftete + Idochlohydroxyguinolone (0.61 mg
+ 1.00mg + 10.00mg + 10.00mg + 1.00mg)
4
Cap Anti Oxidant with selenium & copper (Vit.A, Acetate IP-5000 IU, Vit.E
Acetate 25mg, Vit.C 100mg, Thiamine mononitrate 10mg, Riboflavine 10mg,
Pyridoxin HCL 3mg, Cyanocobalamine 5mcg, Niacinamid 50mg, Folic Acid 1mg,
Calcium Pantothenate 12.5mg, Zinc Oxide 40mg, Cupric Oxide 25mg, Sodium
Selenate 60mcg, Manganses Chloride 1mg, Chromium Chloride 65mcg).
5
Cap Citrus Bioflavonoid Compound 150mg, Ascorbic Acid IP 75mg, Menadione
IP 0.66MG, Ferrous Gluconate IP 67mg, Tri-Basic Calcium Phosphate IP
144.43mg.
6
Cap. Ferrous Succinate BP 200mg, Succinic Acid 210mg, Folic Acid IP 400mc
g.
7
Cap Fluconazole, 150mg.
8
Cap Vitamin A 25000IU equivalent to retinal 7.5mg in water soluble form
9
Cap. Alphacalcidol B.P. 0.25mcg (1@-Hydroxyvitamin D3), Calcium Carbonate
I.P. 500mg
10
Cap. Paracetamol 400mg + Dextropropoxyphen HCl 65mg
11
Carbonyl Iron, Zinc Gluconate, Vit. B12 and Vit. E, Selnium and Folic Acid Syp
12
Cough syrup - Each 5ml contains :
Dextromethorpan Hydrobromide IP 7.5mg, Centrizine Hydrochloride BP 2.5mg,
Zinc, Gluconate USP, Equivalent to Elemental Zinc 7.5 mg, Menthol IP 1.5mg,
Flavoured Syrupy base q.s
13
Cream Anti Inflamatory, containing: Nimusulide 10mg, Methyl Salicylate IP
100mg, Menthol IP 50mg, Capsaicin USP 0.025mg, 30gm,
14
Cream Silver Sulphadiazine Jar, 500gm
15
Drops Iron (each 1ml containing) - Colloidal Iron, equivalent to elemental Iron
25mg + Lysine HCL 200mg + Vit.B12 5mcg + Folic Acid 200mcg - 15ml bottle,
15ml
16
Each 5ml contains - Terbutaline Sulphate IP 1.5mg.
Ambroxol Hydrochloride BP 15 mg, Guaiphenesin IP-50mg, Zinc Gluconate
USP, Equivalent to Elemental Zinc 7.5mg, Menthol IP 0.5mg, Flavoured Syrup
base q.s.
17
Each 5ml contains :
Paracetamol IP 125mg, Phenylephrine Hydrochloride IP 2.5mg., Cetirizine
Hydroc hloride BP 2.5mg, Zinc Gluconate USP, Equiv. to Elemental Zinc 7.5mg,
Flavoured Syrup base q.s
18
Enteral Nutrition powder containing Carb, Fat, Protein) -57 Gm Sachet, 57gm
19
Ferric Ammonium Citrate-160mg(equal to elemental iron 32.8mg) +
Cyanocobalamin-7.5mcg + Folic Acid-0.5mg, 200ml
20
I/V Omega 3 Fatty Acid
a) 10% fish oil emulsion with a high percentage of omega-3, fatty acids
eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA).
b) The polyunsaturated omega-3 fatty acids EPA and DHA serve as precursors
of anti
inflammatory eicosanoids and for cell membrane assembling
21
Infusion Aminoacid solution for parentral nutrition (40%
Amino
Acid+80%Glucose with option of lipid addition port in bag), Celemin 10 plus
200ml,
22
syp. methdilazin2.5mg+amounim chloride .1mg+ sodium citrate 50mg 100ml
23
Inh. Halothane
24
Inh.Isoflurane. 100ml bottle
25
Inj Trimethoprim and sulfamethoxazole 80 & 400 mg
26
Inj Adrenaline (1:10000), 1ml
27
Inj Amidorone
10
Remarks
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
Inj Aminophylline, 10ml,
Inj Amoxicillin +Clavulanic acid 1.2 Gm,
Inj Ampicillin, 500mg
Inj Anti D 300 mg
Inj Botropsae, 1ml,
Inj Calcitrol, 1mcg
Inj Calcium Gluconate, 10ml,
Inj Cefaparazone 1gm + Salbactum 1gm
Inj Cefotaxime 1gm
Inj Dextrose 10%
Inj Dextrose 25% 25 ml
Inj Dextrose 5%
Inj Dextrose 5% with Saline 0.9%
Inj Digoxin
Inj Dobutamine 250mg/ 5ml
Inj Ethamsylate, 250mg/2ml
Inj Frusemide, 2ml
Inj Hydrocortisone Acetate 2ml, 1ml (vial)
Inj. Glycerly Trinitrate 5ml ampule
Inj Imipanam 500mg
Inj Insulin (Human) Cartridges- Mixtard(30/70)
Inj Insulin (Human) Cartridges Plain
Inj Insulin Aspart
Inj Isolyte –P, 500ml
Inj Levofloxacin 500mg IV
inj Lignocaine 1%
inj Lignocaine 2%, 30ML
inj Lignocaine 4%
inj Lignocaine with Adrenaline
Inj Magnisium Sulphate, 2ml
Inj. Mennitol IP 10g + Glycrein 10g per 100ml bottle
Inj.Meropenam, 250mg, 1gm
Inj. Metclopramide 2ml
Inj. Inj. Methyl Prednisolone Sodium Succinate 1gm
Inj. Methylcobalamine 500ug, IV & IM use, No preservative or stabiliser
Inj MVI 10 ml,
Inj Nor adrenaline, 2ml
Inj Normal Saline 0.9 %, 2 Lit (Plastic
Inj Oxytocin, 1ml
Inj PAM, 500mg/2ml
Inj Paracetamol
Inj Parentral Fat emulsion 10% (500ml), 20%(250/500ml),
Inj Pentoprazole 40 mg/ ml
Inj Phenytoin Sodium,
Inj Piperacilin, 4gm + Tazobactum,500mg, Ala
Inj Potassium cloride 10ml
Inj Propofol 1%, 20ml
Inj Prostidin 125mg/ml
Inj Rabeprazole 20mg I/V
Inj Ranitidine, 2ml
Inj Ringer Lactate
Inj Saline, 3%
Inj Sodabicarbonate 7.5%, 25ml
Inj Sodium Bicarbonate-7.5% Isotonic, 10ml
Inj Sodium Chloride, 10ml
Inj Somatostatin, 3mg/1ml
Inj Tetanus Toxoid 0.5ml amp/5ml vial
Inj Tramadol, 2ml,
Inj Vancomycin 500 mg
Inj. Vecuroniun 4mg/2ml
11
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
Inj.Meropenem 500 mg , 1 gm & 250 mg
Inj.Nimodipine
Inj. Octreotide 50 mcg & 100 mcg
Inj. Amoxycillin 1 gm + clavulanic acid .2 gm
Inj. Noradrenaline Bitartarate I.P. 400/2m
Inj. Iron sucrose injection USP 20 mg/ml 5ml
Inj. Verapamil 2.5 mg/ml
Inj. Freeze dried acyclovir I.V. infusion 250 mg/vial
Inj Vitamin A (1 lac units per 2ml)
Inj Vitamin D (6 lac units per 1ml)
Inj Vitamin K 1
Jelly Lignocaine Hydrochloride, 2%
Liquid Paraffin + Milk of Magnesia (200ml),
Liquid Potassium Chloride IP 1.5 gm, (corresponding of elemental Potassium) in
a flavoured, Sugarless base per 15ml, 200ml Bottle
Lotion Betamethasone 0.05% + Salicylic Acid 2% - 50ml bottle
Lotion Clotrimazole 1%, Beclomethason Dipropionate 0.025% w/v, Propylene
Glycol, I.P. 15ml
Lotion Gamma Benzine Hex achloride 1%, 100ml
Mouth Wash - Chlorhexadine Gluconate 0.2% w/v + Sodium Floride 0.05% w/v +
Zinc Chloride 0.09% w/v, 150ml bottle
Multivitamin drops - Drops each ml contains :
Vitamin A Concentrate (Oily form) IP, (As Palmitate) 2500 IV, Cholecalciferol IP
200 IU, Ascorbic Acid IP 25mg, Thiamine Hydrocholride UP 0.5mg Riboflavine
Sodium Phosphate IP Equiv, to Riboflavine 0.5mg, Nicotainamide IP 5mg,
Pyrdoxine Hydroxide IP 0.5mg, D-Panthenol IP 1.5 mg, VitmainE Acetate IP
2.5mg.
Natural Compound Medical Dressing Solution 50ml
Oint Benzoic Acid 12% + Salicyacid 6% + Hydrocortisone Acetate 0.5% w/w
15gms
Oint Betamethasone + Salicylic acid, 20gm, Besa-6
Oint Povidone Iodine, 15gm, 500gm
Gel. Diclofenac Diethylamine B.P 1.16% w/w equivalent to diclofenac sodium
B.P 1% w/v. Capsaicin USP 0.025% w/w. Methyl salicylate IP 10% w/w.
menthol IP
5% w/w. 30 GM TUBE.
Powder Clotrimazole, 75gm
Rotacap- Beclomethasone 50, 100ug
Rotacap-Budesonite100ug, 200ug.
Solution 6% Hydroxy Ethyl Starch (130/0.04) with molecular weight 130,000
daltons; degree of substitution, 0.4 in isotonic sodium chloride
Solution Gention violet 1% 100ml pack
Solution Budesonide for nebulizer
Solution Cetrimide 15 %, Chlorhexidine 7.5% 1 liter packs,
Solution Formaldehyde, 5ltr,
Solution Ipatronium for nebulizer
Solution salbutamol for nebulizer, 15ml,
Syp Cetrizine 5mg/5ml, 30ml,
Syp. Zinc Acetate-50ml/100ml
Syp Cyproheptadine HCL 2mg + B1 2.5mg + B12 2.5mg + B6 0.75mg + DPanthenol 2.5mg + Neacinamide 22.5mg/5ml - 200ml bottle
Syp Dextrometharphan 5mg + Ammonium Cloride 60gm + Chlorpheniramine
Maleate, 2.5mg + Gualphenesin 50mg (100ml bottle)
Syp Digoxin
Syp Enzyme (each 15ml containing) - Diastase (1:50) 60mg + L-Lysine Mono
HCL 90mg + Vit.B1 3mg + Vit.B6 1.5mg + Vit.B12 5mcg + D-Panthenot 5mg +
Niacinamide 24mg – Syrup base 200ml bottle
Syp Erythromycin 125mg/5ml - 30bottle
Syp Glycerol, 500ml
Syp Iron (each 5ml containing) - Colloidal Iron, equivalent to elemental Iron
250mg + Folic Acid, 500mc g + B12 5mcg - 200ml bottle
Syp Iron : Ferric AmmoCitrate 160mg + Vit.B 125mcg + Folic Acid 1mg + Zinc
12
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
Sulphate 40mg
Syp Multi Vitamin Each 5ml Contains: Vita-A-2500I.U.+ Cholecalciferol 200I.U. +
Vita E -7.5 I.U. + Thiamine Hck-2mg+ Riboflavin-2.5mg + Pyrudixube Hcl-1.0mg
+Vita. B12- 1Mcg+ Vita. B3-22.5mg + Asorbic Acid – 40mg + Zinc Sulphate1mg + Potassium Iodide- 50mcg + ch
Syp Ibruprofen 100mg + Paracetamol162.5mg each 5 ml
Promethazine 5mg + Paracetamol 125mg each 5 ml
Syp Paracetamol, 60ml
Drop. Dicyclomine Hcl 10m + Simethicone 40mg /10 ml
Tab. Atorvastatin 20mg
Tab Amiodarone, 200mg.
Tab Amlodopine 5mg + Atenolol 50mg
Tab. Pantaprazole Sodium 40mg
Tab. Pantaprazole Sodium 40mg+ Domperide 10mg
Cap. Omprazole 20mg + Domperidone 10mg
Cap Amoxicillin 250mg/500mg
Tab. Fluconazole 150mg
Tab Amoxicillin + Clavulanic acid, 1 gm per tab
Tab Amoxy+Clavulanic Acid, 625mg, (per tab
Tab B. Complex - Thiamine Mono Nitrate Ip 10mg, Pyridoxin Hydro Chloride Ip 3
Mg, Cynocobalamine Ip 15 Mcg, Riboflavin Ip 5 Mg, Nicotinamide Ip 50mg.,
Calcium Pantothenate IP. 5mg.
Tab Calcium Carbonate
Tab. Progesterone 400 mg (vaginal/rectal pessaries)
Tab Cefuroxime Axetil, 250mg/500mg, (per tab
Tab Ciprofloxacine, 250mg/500mg
Tab Diclofenac Potassium 50mg + Paracetamol 500mg + Chlorzoxazone 250mg
Tab Diclofenac Sodium SR-75,100 mg.
Tab. Cefphodoxime Profetil 50mg/100mg/200mg
Tab. Cefurxime Axetil 125mg
Tab. Leofloxacin Hemihydrate 500mg
Tab. Doxyphyline 400mg ER
Tab Ethamsylate 250mg/500mg
Tab Ferrous sulphate (equav to 60mg of elemental iron)
Tab Gabapentin 400mg
Tab Gliclazide 80mg + Metformin 500mg
Tab Glipizide (sustained released)
Tab Ibuprofen 400mg
Tab Iron containing - Ferrous Furmorate 152 mg, Zinc Sulphate 61.8mg, Folic
Acid 75mg
Tab Iron Folic Acid (ferrous sulphate exsiccated IP 333-335mg (equiv.to100mg
of elemental iron)+folic acid IP 0.5mg
Tab Methylcobalamine 500 ug , 1500 ug
Tab Ofloxacillin 200mg + Tinidazole 400mg
Tab Paracetamol 500mg
Tab Rabeprazole 20mg,40mg
Tab Ramipril 5 mg.
Tab Ranitidine, 150mg
Tab Spirolactone + Frusemide (50mg + 20mg)
Tab. Loratadine 10mg
Tab. Levocetrizine 5mg
Tab vilda gliptin 50 mg (anti Diabitic)
Urine Alkalinizer containing Disodium Hydrogen Citrate 1.38 – 1.55gm/5ml100ml Bottle,
13
Tender Group No. II
List of items for General Surgical Consumables
S.No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
Name of Item
Abdominal Sponge, hydrophilic non-woven,3layer,Lycra Pipin Bounded with
radio opaque marker & long string size: 30cm X 30cm, 20 X 20cm
Reusable)ETO Sterile
Abdominal drainage set , sizes 22,24,26,28,30
Aerosol Mask Transparent Mask With Nose Clip, Feathered Edges With Star
Lumen Tube
Alcohol Based disinfectant with
50 g 1-propanol, .075 g Didec
yldimethylammonium Chloride per
100 grams solution (in tissue & spray form)
Alcohol swabs
Anaesthetic Kit consisting of OT Half Gown-1pc, Face Mask-1pc, Cap-1pc,
Spinal Drape-1pc (all non-woven spunlace, impervious & breathable fabric),
Hydrophilic lint free Swab-5pc, ETO Sterile
Bandages - Cotton Roll (10cm X 5mtr) (Dzn)
Bandages - Cotton Roll (15cm X 5mtr) (Dzn
Black Breaded Silk Suture 2.0 Silk Roll (box of 06)
Closed Wound Suction Unit (ADULT) ( 12,14,16G
Complete Mask With Tubing For Nebulizer Disposable
Disposable Surgeon Gown (small, medium, large) [Water repellant, breathable,
splash res istant
surgeon's gown
Abdominal Swab With Radio Opaque Thread (30x30cm 8 Ply)
Adhesive Plaster, 7.5 cms x 5mtr (per spool
Band Aid (WaterProof)
Black Breaded Silk Suture 1.0 Silk Roll (box of 06)
Blood Transfusion set
Coated Polyglactin 910 (Rapid) Episiotomy Suture with double needle ½
circle round bodied, ½
circle, reverse c utting, 36mm 140cm (size: 2/0) (box of 12)
Corrugated Sheet Plastic/Silicon
Cord Clamp Disposable Sterile, Pyrogen Free
Cotton Crepe Bandage (10 cm x 4m)
Cotton Crepe Bandage (15cm x 4m)
Cotton Wool Roll (500 Gms)
Disposable draw sheet
Disposable Nebuliser Chamber Different Sizes
Disposable Sterile Syringes (single use) 50/60ml
E.T. Tube Holder (Adult/neonatal), latex free with two part system which includes
soft cushioned neckband with tube channel and adhesive backed base with
velcro strip that adheres to neckband
Elastic Self Adhesive Bandage (10cm X 4mtr)
Elastic Self Adhesive Bandage (6cm X 4mtr)
Elbow length procedure gloves for Labour Room, flexible, size - 6, 6.5, 7
General Surgery Drape non-woven spunlace, impervious & breathable with
medical grade Opsite, size: 140cm X 300cm(sheet) & 18cm X 45cm(Opsite),
ETO Sterile
High Point Extension Tube Spirally Coiled With Male, Female Leur Lock In
100cm,150cm With Volume < 1ml
High Risk Prevention Kit for Patient consisting of Bed Sheet-1pc, Pillow
Cover1pc, Patient Gown- 1pc, Plain Drape-2pc, General Surgery Drape-1pc (all
made of non-woven spunlace, impervious & breathable fabric), ETO Sterile
High Risk Prevention Kit for Surgeon consisting of OT Gown-1pc, Hood Cap1pc, Face Mask-1pc,
Leg Cover-1pair (all made of non-woven spunlace, impervious & breathable
fabric), Surgeon
Gloves-1pair, Eye Protection Glasses-1pc, ETO Sterile
Hydrogel dressings for Bed Sores Sizes:- 6x12 cms,10x12 CM,12x24 CM, Dis c
14
Remarks
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
of 5cm & 6.5 cm Diameter. Oval Dressing size;- 5.5X 11 CM.
Incision drape, Sterile, disposable
Karman Cannula For Endomaterial Aspiration, 6,7,8,10,12 With Adaptor
ECG Jelly
Folley's Catheter Size 14 & 16, 2 Way
Folley's Catheter Size 14 & 16, 3 Way
Gauze Than (90 Cmsx18 Meters)
Gloves Powder - Absorbable
Glycerin Enema
Hourly Urine Measurement Bag (Adult/Paed)
I.V. Cannula Size 16, 18,20,22 With Integrated 3 Way Stop Cock
I.V. Cannula Size 24 With Integrated 3 Way Stop Cock
I.V.Set (Non-vent)
Infant (Nasogastric) Feeding Tube Size: 5-10
Mack-In-Tosh (per meter)
Micropore Surgical Tape Non woven viscose rayon porous backing with acrylate,
Hypoallergenic adhesive. (Size - 1",2",3" x 10 yards)
Mini vac suction drain - Size 8,10,12fr
Non-Absorbable Silk Suture On Round Body 1/2 Circle Needle (No.1-0 to No.40)
Non-Absorbable silk Suture With Cutting Needle 3/8 Circle (No.1-0 to No.4-0)
Normal Delivery Kit consisting of Lithotomy Sheet with Leggings & Garbage
Collection Funnel attached-1pc, PHMB antibacterial processed Dripping Sheet
made of highly absorbent, lint free, hydrophilic non-woven-1pc, Gynae Pads
highly absorbent, hydrophilic non-woven-5pc, Plain Drape-1pc, Cord Clamp-2pc,
ETO Sterile
O.T.Wear Kit for Prevention of HIV (Sterile) - wrap around gown of air permeable
and Impervious Material, Face mask 03 layered, Cap, Leg cover and Goggles.
Polyglactin suture on round body 1/2 circle needle (No.1, 1-0 to 4-0)
Polypropylene Monofilament on R.B. Needle ½ circle (No.1-0 to No.4-0)
Silicon Folleys Catheter Size 8 To 24F
Stilet for E.T.Tube
Surgeon Caps Disposable (Size: Unisex)
Surgeon Mask Disposable, Tripple Layered
Thermometer Oral & Rectal, Digital
Three Way Cannula
Ultrasound Jelly
Vacuum Suction Drainage Set Disposable 8,10,12,14 sizes
Tourniquet
Kelly's Pad Rubber
Leg U drape O cut, Sterile, disposable
Leg U drape U cut, Sterile, disposable
LINT (POUCH OF 500 GRM.)
Lithotomy Sheet
LP Drape Disposable Sterile
Malecot Catheter (size-12,14,16)
Measured Volume Set (110ml)
Measured Volume Set (150ml)
Monopolar loop for total and sub total Hysterectomy
Mucus Extractor
Multi lumen IV extension tubes
Neo born baby kit, PHMB antibacterial processed consisting of Baby Shirt, Baby
Cap, Baby Napkin, Baby Mattress with PVC Lining, Wraparound & Mosquito net
for face
Neo-natal IV sponges, non-woven, highly absorbent, lint free hydrophilic
material with strong medical grade adhesive & PHMB antibacterial processed to
prevent microbial growth
Nylon suture on cutting needle 3/8 circle (No.1-0 to No.3-0)
OT Apron, upto k nee length, made of Impervious Rubberized Polyester material
& Spun cotton, pipin bounded with strings & autocleavable
OT Full Gown, Non-woven spunlace, Impervious & Breathable, universal fit,
15
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
stockinet at cuffends, double overlap, ETO Sterile
OT Towel made of Lint free Spun Cotton( Cotton-70%, Viscous-30%) &
Rubberized polyester impervious material ,Logo of the Hospital, autoclavable,
Size: 27" X 34"
Paraffin Gauge (Sterile) (pack of 20pcs)
Plain Drape PE, medical grade odorless & clear PP, with adhesive on sides,
size: 100cm X 100cm ,100cm X 150cm,120cm X 200cm , 120cm X 300cm ETO
Sterile
Presterilised sheets for draping during s urgery with a hole of 10" size 24"x12" &
36"x 24"
Reusable Earthing Pad ,Capacitive, Non-Adhesive, Non-sticky, Akton polymer
made compatible with any brand
Shoe cover pair.
Silicone Double Nasal Tube For Neonatal Ventilation Catheter Length 4 Cm
Sofratulle dressing
Sterile Specimen Containers (100ml, 250ml, 500ml, 1000ml)
Sterile Surgical Dressing Pad Gamma Sterile 10x10cm & 20x10cm
Sterile Transparent Wound Dressing (variable sizes)
Surgical Hand Coutry pencil PTFE
Swab, Highly absorbent, lint free, non-woven hydrophilic material size: 5cm X
5cm, 7.5cm X 7.5cm, ETO Sterile
I.V. Canula
Trocar Drain For Pleural Drainage Of New Born Pvt Xro Marking Every Cm. One
Lateral Sys. Female Luer Lock
Urine Collection Bag with botton outlet
Urine Sample Collection Bottle
Yankaur Suction Set Sterilized 2.5 Mtr Long tube With Connector To Fit In Any
Suction Machine, Transparent
Cromic Catget Suture size 2.0, 1.0, 1, needled half circle, ¼ circle
Plain Cromic Catget Suture size 2.0, 1.0, 1, needled half circle, ¼ circle
Cromic Catget Suture Nio.1 half circle trocar pointed
Vicryl no. 1, 1.0, half circled, cutting and round body needle
16
Tender Group No. III
DEPARTMENT OF LABORATORY2009-2010
(NON- CONSUMABLE)
(CONSUMABLE OF EQUIPMENT, IF ANY MAY BE QUOTED SEPARATELY)
NON CONSUMABLS – biochem
1
2
3
4
Semi automated biochemistry analyzer –
1) Compact microprocessor – controlled, general purpose bi-chromatic
photometer system with at least six filters ranging from 340 nm to 700 nm, to
read & calculate results of both end point & Kinetic colorimetric assays.
2) Temperature – 37oC – Peltier based temperature control.
3) Light source – tungsten Halogen lamp
4) Measurement modes – Absorbance, Concentration, turbidometry
5) Calculation modes – single standard, multistandard – linear & nonlinear,
factor, kinetic
6) Input – Facility to attach external key board
7) Output – built in printer & facility to attach external dot matrix printer
8) Measurement range 0.00 to 2.50 absorbance units (A)
9) Measuring device: Facility to use both cuvettes and flow cells
10) Ability to generate patient work list, reports and quality control data for not
less than two levels for 50 parameters or more.
11) Facility to transfer data via LIS
12) Store reagent performance data (blank absorbance), calibration curves,
Levy- Jenning plots and not less than 1000 patient results
13) One spare flow cell, 12 cuvettes, two bulbs, and 10 printer paper rolls to be
supplied along with equipment.
14) Compatible online UPS with battery back up of at least one hour
15) with separate computer and printer
Cell counter 3 part –
Hematology analyzer based on impedance principal having 18 parameters i.e.
HGb,wbc count, 3 part differential, MCV,MCH,MCHC,HCT,RBC count, plt count,
MPV, RDW-CV, SD, PDW, P-LCR with whole blood and capillary modes, sample
rotator valve with separate channels for wbc and rbc counting with floating
discriminators for each, clog removal with minimum through of 60 samples/hour
with result on screen and printer reagents to be available in Indian rupees. The
instrument should have aperture monitoring facility and also employ time and
volume count for better results
Cell counter 5 part –
Five part differential heamatology analyzer based on flow cytometry principle,
with parameters viz WBC, lympho# %, neutron # %, mono #/%, eosinophil #/%,
baso #/%, RBC,HGB,HCT,MCV,MCH,MCHC,RDW-CV, REW-SD,
PLT,MPV,PDW,PCT4, Reticulocyte count %, 2 histograms for RBC and PLT, 2
scattergrams for Basophils & differential scattergram Perfprmance parameter
WBC Linearity range 1.00-99.99, plt linearity range 10-1000. Reasearch
parameter includes 2 histograms for RBC and plt: tft touch screen with external
laser printer.
Binocular Microscope –
binocular microscope iso 9002 approved, with four objectives on reverse nose
piece, wide field eye pieces with foldable eye guards, 20 watt halogen bulb light
at base with easy accessibility of bulb with input volt range 90 to 240, mechanical
stage 150mm x 135 mm with 76 x 50 mm movement supported on ball bearing
guideways, coaxial focusing with autofocus stop, with stage moving knobs at
lower right side, xl model
ACL 7000 Specifications
1. Instrument should have a flexible test menu with clotting, chromogenic
and
immunoassay capabilities
2. Instrument should have a centrifugal analysis principle
3. Should have a nephelometric (at 660nm) and absorbance (405nm) reading
4. Instrument should have a internal barcode reader for sample identification
17
Unit
Unit
Unit
5
5. Reagent volume for factor assays should be 40 microlitres
6. Instrument should have auto dilution for samples and calibrations
7. Instrument should have 2 probes for sample and reagent
8. Expression of results for PT should be in seconds, activity& ratio or INR
9. Precision in analyses should be < 1 %(cv-pt),<2% (cv-aptt)
10. Instrument should use primary blood tubes and sample cups.
11. Instrument should collect and compute 1100 consecutive light scatter
readings per reaction for better precision
Coagulation Analyzer with consumables:
Specifications:1. Instrument should have a flexible test menu with clotting, chromogenic and
immunoassay capabilities
2. Instrument should have a centrifugal analysis principle
3. Should have a nephelometric (at 660nm) and absorbance (405nm) reading
4. Instrument should have a internal barcode reader for sample identification
5. Reagent volume for factor assays should be 40 microlitres
6. Instrument should have auto dilution for samples and calibrations
7. Instrument should have 2 probes for sample and reagent
8. Expression of results for PT should be in seconds, activity& ratio or INR
9. Precision in analyses should be < 1 %(cv-pt),<2% (cv-aptt)
10. Instrument should use primary blood tubes and sample cups.
11. Instrument should collect and compute 1100 consecutive light scatter
readings per reaction for better precision
Unit
6
Slide warming table – Digital
Slide Warming Table should be rectangular flattening table intended for clinical
histopathology with a jet Black Aluminum Surface ensuring very high thermal
conductivity rates & exceptional resistance to mechanical exploitations
temperature ranging from ambient to 70° C can be Selcted. The programmed as
well as set temp should be displayed on the instrument & set values memorized
by a built-in battery backup system. The instrument should be modern.
Top Plate Size : Length X Width
300 mm X 200mm
The product should be CE Marked.
Unit
7
VDRL rotator –
Should be useful for VDRL & other agglutination tests, blood grouping test & for
mixing of solutions in small flasks, beakers & bottles. Should be fitted with Timer.
The rotator should have large platform size of 300 X 300 mm which should take
concave slides, blood bottles & flasks held by spring holder. Should have a with
Digital speed controller & Indicator as well as Digital Timer of 0 to 199 minutes to
control the shaking duration. Should work on 220V single phase 50Hz AC
supply.The product should be CE Marked.
Slide staining container with slide holding rack
(SS), Vertical for 30 pieces. SS Rack with SS container medium and large
Blood vial rotator
For uniform mixing of blood for better results on fixed and variable speed.
Rocking and rolling motion, fully adjustable moving angle, speed 2-40rpm, for20
tubes
Test Tube Holder Material-SS 18G/20G
Sizes-Small/Medium/Large
Needle burner and syringe destroyer
Should destroy both i.e. needle and syringes in a safe, ecofriendly and cost
effective manner. Should have provision for inserting the used needle to the
small hole provided and the needle should be destroyed with in seconds.
Specially designed electrodes should generate high temperature to instantly
incinerate the needle. Should have provision for inserting the syringe on the top
of the machine in the big 2ml hole provided with a cutting blade, just pulling the
lever should cut the syringe into two . Should have tray is built in to collect needle
residue & Syringe container to collect syringe bodies after cutting. Should be
provided with battery backup with built in power source trickle charger. The
Unit
8
9
10
11
18
unit
unit
unit
Unit
battery should constantly charge when the main is on. It should automatically
shift to battery power in case of a power failure without disturbance in the
operation. Should be fitted with an overload trip device.
The product should be CE Marked.
12
13
14
15
16
17
18
Manual cell counter 8 units
Physical weighing balance for laboratory for weighing chemicals 0-100 grams
Centrifuge machine
Should have a digital timer
Body should be made of strong fabricated & corrosion resistant steel
Control panel – for start/stop switch, dynamic brakes, step less speed regulator
with zero start switch & speed indicator with timer and protective fuses.
Door interlock Maintenance-free brushless drive motor with exact speed pre
selection and digital display in control panel. Speed range 100 to 6000 rpm and
above.
Tube Holders as appropriate
Shall meet IEC-60601-1-2:2001(Or Equivalent BIS)
General Requirements of Safety for Electromagnetic Compatibility.
The unit shall be capable of operating continuously in ambient temperature of 10
-40deg C and relative humidity of 15-90%
The unit shall be capable of being stored continuously in ambient temperature of
0 -50deg C and relative humidity of 15-90%
The supplier should be ISO certified for quality standards.
Product should be FDA/CE or ISI approved
Should comply with IEC/TR 61010-3-020 :Safety requirements for electrical
equipment for measurement, control, and laboratory use - Part 3-020: Conformity
verification report for IEC 61010-2-020:1992 Particular requirements for
laboratory centrifuges"
Should comply with IEC 61010-1 Safety requirements for electrical equipment for
measurement, control, and laboratory use – part 1:
Microslide Cabinet - Horizontal Manner
Should have a storage for atleast 10,000 slides .Should be useful for safe and
easy handling of 75 X 25 mm slides. Construction should be of CRC sheet, well
designed for its performance, durability and appearance. Should be powder
coated paint outer finish with smooth working doors fitted with handle, lock and
key.
The anodized seamless moulded ( die- pressed) aluminum slide strays for
holding 75 X 25 mm slides, should be arranged separately so as not to disturb
other compartments while taking out or putting in the slides.
The size of the tray should be 335 X 230 X 35 mm and should be properly fitted
with uniformly slotted aluminum carries in four rows, each holding 50 slides i.e.
each tray should hold 100/200 slides in horizontal position and should be fitted
with index holder. Slider holding slotted rows should be numbered 1 to 50 to
identify the slides.
The manufacturer should be ISO & WHO-GMP certified. The product should be
CE Marked.
unit
unit
UPS battery 12V, Dry Battery
Pharmaceutical Refrigerator Capacity
( i) 330 Ltrs
Specifications Should have drawers/ shelves
Should have cross flow blowers
Should have fully automatic temperature controls.
Should not be effected by ambient changes
Insulation should be not less than 55mm in any case
Door should essentially be solid door.
Should have a 365 days temperature & humidity recorder paperless
Should be supplied with Voltage stabilizer
Lab refrigerator
720 lts
Unit
.unit
19
unit
unit
unit
19
20
21
22
23
Specifications Should have drawers/ shelves
Should have cross flow blowers
Should have fully automatic temperature controls.
Should not be effected by ambient changes
Insulation should be not less than 55mm in any case
Door should essentially be solid door.
Should have a 365 days temperature & humidity recorder paperless
Should be supplied with Voltage stabilizer
Centrifuge Machine –
 Heavy duty with digital timer, speed setting,
capacity 36 tubes
Water Bath Digital
Should be ISI Mark
Should provide exceptional temperature control of liquid for uniform and stable
temperature.
The inner chamber of the Water Bath should be made of seamless corrosion
resistant stainless steel grade 304 for a longer life time and easy cleaning &
External Material should be M.S Sheet, Power Coated. Excellent temperature
uniformity should be obtained by incorporated PID control system which
maintains the temperature very precisely.
The system should have a high wattage heater to act in response to any settled
temperature more quickly compared to other systems, but only a fraction of the
heater wattage should be consumed when the set temperature has been
achieved, saving lot of energy.
Should have in built soft start for heaters to prolong the heater life.
Should have auto key lock feature to ensures no manipulation could be done
within the system while being operated by an un-authorized person.
The unit should incorporate user friendly feather touch buttons for setting
temperature, delay time and process time which should be visible on seven
segment display. LEDs should indicate the mode of operation. All the process
date should be recorded to remote computer via RS232/RS485. Also should
have an attachment for the printer. Should have remote monitoring alarms &
controls.
Should have Data Retentive Delay and Process Timer to ensure that the material
inside is objected to the set temperature for the set time only, irrespective of any
power cuts or voltage fluctuations.
Temperature Range should be Ambient-80°C, Temperature Sensor should be
RTD (PT 1 00). Control System- PID, Programmable Microprocessor,
Temperature Set & Display Sensitivity should be O. l°C. Temperature Fluctuation
should not exceed +0.l°C.
Timer - 999 Min delay +999 Process, Should work on 230v,50 Hz. AC.
Internal Dimensions: WXHXD 330 x 300 x 150 mm for 4packs
The product should be CE Marked.
Cytospin Cytocentrifuge
Low speed centrifugal force to separate &deposit on slides, cyofunnel load on
tilted position to prevent cell loss. Programmable acceleration speeds 200-2000
rpm capacity for spinning 4- 12 samples simultaneously. Autofixation mode &
improved lid mechanism
FNAC syringe holder
Incubator
.
unit
unit
LIST OF CONSUMABLE ITEMS
RATES TO BE QUOTED IN AS PER OUR PACK SIZE ONLY AS AND WHERE MENTIONED. NO OTHER
RATES OF DIFFERENT PACK SIZE WILL BE ACCEPTED AT ANY CONDITION
1.
Biochemistry Kits
20
a.
Uric acid enzymatic end point, single reagent in stable liquid form kit with standard
125ml
b.
Creatinine kinetic test kit jaffe fixed time test with stable reagent in liquid form with
standard
200ml
c.
Urea kinetic GLDH method kit with reagent in stable liquid form with standard
200ml
d.
Total bilirubin kit D.M.S.O. method single reagent for total bilirubin with separate
sodium nitrite solution without need of sample blank with each test with standard
2x250ml
e.
Direct bilirubin D.M.S.O. method single reagent kit with separate sodium nitrite solution
without need of sample blank with each test with standard
Serum glutamate oxaloacetae transaminase test kit IFCC/MDH/NADH kinetic single
step with stable reagent in liquid form
2x250ml
g.
Serum glutamate pyruvate transaminase test kit IFCC/LDH/NADH kinetic single step
with stable reagent in liquid form
250ml
h.
Alkaline phosphatase kinetic reagent kit IFCC/PNPP method, single step, stable
reagent in liquid form
250ml
i.
Protein biuret reagent kit end point with standard
2x50 ml
j.
Albumin bromocresol green reagent kit end point with standard
2 x 50ml
k.
Glucose reagent in lypholized form GOD/POD end point with standard
10 x 100ml
l.
Total cholesterol reagent enzymatic/POD end point single stable reagent in liquid form
with standard and calibrater
250ml
m.
Hdl cholesterol third generation direct homogeneous method based on selective
solublizing effect by use of special surfactants having two reagents ready to use liquid
stable till expiry with standard and calibrater
160ml
n.
Ldl cholesterol third generation direct homogeneous method based on innovative
surfactant technology with ready to use two liquid stable reagents stable till expiry with
standard and calibrater
160ml
o.
Triglyceride test kit lipase/glycerol KIN/GPO/PEROX. End point single step stable
reagent in liquid form with standard
250ml
p.
Calcium kit arsenazo III end point, single reagent in liquid form stable at room
temperature with one to two min incubation with standard.
Phosphorous kit with molybadate UV end point stable reagent in stable liquid form kit
with standard
Lactate Dehydrogenase enzyme kinetic kit DGKC single step reagent in stable liquid
form kit
Serum amylase kit in stable liquid fom , CNP –G3 method kinetic kit
Liquid assayed multi quality control human serum based chemistry controls in three
levels, 3 year shelf life at -20 degrees, 30 days unopened stability at 2 – 8 degree
centigrade, 14 day open vial stability at 2 – 8 degree c, all three levels
For electrolyte analyzer – rapid chem. by Siemens
Rapid chem.. Reagent (trouble shooting kit)
Daily cleaning solution
Reagent kit
Urine Diluent
Sample cups
Pump tubing
Electrodes
Controls for electrolyte analyzer. – trilevel standard company
3x50ml
f.
q.
r.
s.
02.
03.
a.
b.
c.
d.
e.
f.
g.
4.
21
250ml
1x125ml
30ml
8x1ml
12x5
50ml
50ml
Unit
500ml
Unit
Unit
Unit
10x3ml
5.
Strips for Glucometer – accucheck
6.
7
8.
a.
b.
c.
d.
e.
f.
9.
a.
Controls strips for glucometer
Distill water (double distillation)
For cell counter – H3D Premier by Diagnova RFCL
- Hematon plus – Diluent
- Hemaref II - Rinsing solution
- Cell lyse - Lysing agent
- Hemaclean - Cleaning solution
- Probe cleanser
- E-Z cleanser
For ESR analyzer - med India ESR analyzer
Citrated tubes for ESR – (evacuated/ non evacuated) ESR tubes for med India ESR
analysis, Monitor J, EDTA/Non-EDTA sample compatible tubes
Disposable droppers 2ml, 3ml,5 ml
For electronic hemoglobin meter – hemocontrol by Diamed
Strips for hemoglobin meter
Drabkins reagent
Hemoglobin pipette
Cuvettes
Capillary tubes for CT 12” size
RBC pipette
WBC pipette
Liquichek haematology 16 control with 6 month shelf life trilevel for haematology
analyser
b.
10.
a.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
New improved neubauers counting chamber
Glass Beaker Borosil Make
10ml, 250ml, 500ml, 1000ml. each
Cover slip big 22 x 50 mm of optically flat english glass no 1
Cover slip 22 x 22 mm of optically flat English glass no 1
Whatmann filter paper circular 10 cm diameter
Filter paper sheet of fine quality, whatmann type 75x 46 cm size
Glass marking pen (OHP marker pens)– Black, Blue, Red
Glass Rods
Glass test tubes with rim 12 x 75mm, (Borosilicate Glass Heat Resistant)
Glass test tubes without rim, 12x100mm (Borosilicate Glass Heat Resistant)
Holder for Vacutainer syringes
Immersion oil for microscopy
Lens cleaning Solution
Pasture Pipette (disposable)
Printing paper for analyzers (57mm, 100mm)
Stickers white 20 x 15 mm (SDDMSC printed, bar-coded with date for lab reporting) Stickers white 50x 20 mm printed SDDMSC
35.
Stickers white 50x 20 mm printed SDDMSC
36.
37.
38.
39.
40.
41.
42.
Test Tube Rack, Aluminium 96 holes, 46 holes
Disposable tips 5-200/ (Yellow)
Disposable tips 200-1000/ (Blue)
ml blueDisposable tips 5-20
Tooth Picks
Tourniquet
Sterile evacuated blood collection tube (plastic) with powdered sodium fluoride for
Blood sugar [EDTA+fluoride) tube size 13X75mm with 2 ml draw volume
Sterile evacuated blood collection tube (plastic) with K3 EDTA (Silicon Coated) [K3
EDTA 7.5%] spry dried for hematology – tube size 13X75mm with 3 ml draw volume
Sterile evacuated blood collection tube (plastic) with 3.2% buffered sodium citrate for
coagulation tube size 13X75mm with 2.7ml draw volume
43.
44.
22
50tests/
bottle
--5 liter
20l
20l
1000ml
17ml
100ml
Unit
Unit
Unit
1000ml
Unit
Unit
100/pack
Unit
Unit
6 x3 ml
Unit
10 gm
10 gm
100 no..
Rim 500
Unit
Unit
Unit
Unit
Unit
100ml
100ml
Unit
Each roll
30x75x12
100 per
sheet
100 per
sheet
Unit
Unit
Unit
Unit
Box
Unit
Unit
Unit
Unit
45.
46.
47.
48.
49.
50.
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
Sterile evacuated blood collection tube (plastic) with acrylic gel & clot activator for
serum chemistry determination – tube size 13x75, 13x100 with (3,5,7ml draw volumes
Sterile evacuated blood collection tube (plastic) plain with clot activator for serum
chemistry determination – tube size 13x75, 13x100 with (3,5,7ml draw volumes
Vaccutainer needle
Vaccutainer system for pediatric blood collection
Unit
Vaccutainers Needle Holders
Serum separator vial
Attached hinged cap, 2 ml capacity with sticker, air tight
Permanent marker thick tipped
Lancets with pen device and disposable lancet
unit
Unit
Unit
Unit
Unit each
Unit
1 Pen
with1000
Lancet
Pack of 100
Unit
each
Tissue paper – good quality
Tissue roll – good quality
Measuring cylinder borocil make of class A quality certificate – 1000ml, 500ml, 250ml,
100ml and 10 ml Each
Conical flask – borosil make of class A quality certificate for stain preparation –100ml,
500 ml, 1000ml Each
Slides – deluxe size 25x75mm , 1.45mm thick, polished edges, lint free packing, with
frosted end one side for labeling
Toniquet (rubber, Velcro)
Autopippets - 1000µl,100µl, 200µl.(single channel, fixed), variable volume – 10100microl, 100-1000micro lt.
Prothrombin time test kit reagent in stable liquid form along with CaCl2 (0.25 MOL%)
solution
Partial thromboplastin time with kaolin reagent in stable liquid form along with CaCl2
(0.25 MOL%) solution
Stopwatch
Rack for tips
Rack for pipettes
Microcuvette for Hb & Hematocrit with 10ul of capillary, venous or arterial blood for
haemoglobinometer
Rubber Tubing- Tourniquet
Blood Grouping Tiles- sp
- Blood grouping tiles (1. One set 2. reusable)
- Transparent with individual slot steps
Urine Container (Plastic)
Slides deluxe size 25 x 75 mm,1.45 mm thick,polished edges & lint free packing made
from optically flat glass,delux model
4 Blood Grouping Tiles- 1. One set 2. Reusable
3. Transparent with individual slot steps
blood grouping kit
pasture pipette (glass)
Each
50slides/box
Unit
Unit
12x5 ml
12x5ml
Unit
Unit
Unit
50 test
Unit
Unit
Unit
50 slide
/box
.
unit
10x3 ml
unit
SEROLOGY
72
73
74
75
76
77
78
79
80
81
82
Typhi RAPID,IgG /IgM
RPR card test for syphilis
TPHA test for syphilis
Hbsag rapid card test (sens 1ng/ml) with positive control in each card Approved
for blood bank use by drug controller
CRP slide test with controls with sensitivity of 6 mg%
Rheumatoid arthritis Factor latex kit with controls
ANA Profile (LIA) with 15 antigens
Pregnancy card sensitive as low as 25iu/ml with in built control, store at room
temperature. Result as early as 1 min. 100% specificity
ASO latex kit with positive and negative controls and sensitivity 200 units/liter
Procalcitonin Q
Widal slide test kit coloured antigen for salmonella typhi O,H & Salmonella
23
unit
unit
Unit
unit
50 test
50 tests
unit
50 Tests
25T
5 ml x 4
83
84
85
86
87
88
89
90
91
92
93
94
paratyphi AH, BH
HCV rapid card / spot to detect antigen con ns3, ns4, ns5 (4 th generation) test kit
with positive control incorporated in each card approved for blood bank use by
drug controller
Rubella IgG & IgM rapid test
TORCH Profile (LIA 16T/kit)
Filariasis kit
leshminiasis detection kits
Rapid meningitis combo kit with positive and negative controls
Rapid Immunochromatographic Test for Malaria with Antigen capture assay of P.
Falciparum and P.VIVEX
Strip to test albumin and sugar in urine
Ketodiasticks for testing glucose and ketone bodies in urine
Multistix to test for sp.gr, ph, glu, prot, bil, urobil, ketone, blood, nitrite in urine
Lugols iodine
Strips for detecting occult blood in stool basd on benzidine and H2o2 reaction
UNIT
50 tests
50 tests
30 tests
50 Test
100 strip
50 strip
100 strip
25 strip/ box
CYTOLOGY
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
Koplin jar Horizontal lid glass.
Koplin jar Vertical lid glass.
Koplin jar, Vertical With lid portable
Slide staining jar with ground glass lid for 30 pieces
Ethyl alcohol AR
Methanol AR
Formaldehyde 40%AR
DPX mountant
Leishmans stain
Lieshmans powder with solution
Xylene AR sulphur free
Brilliant cresyl blue for reticulocyte count
Brilliant cresyl blue powder
Sodium citrate
Sodium citrate powder
Sodium chloride powder (pure grade)
Dibasic sodium phosphate anhydrous
Monobasic sodium phosphate anhydrous
Geimsa stain
Giemsa powder
Eosine
Methylene blue
98% sulphuric acid
Haematoxyline
EA 50
OG-6
1% Acitic Acid
Sulphosalicylic acid
Sulphur poweder
Benedicts reagent
Light green
Gills hematoxyline
Harris hematoxyline
Fields stain A
Fields stain B
Rapid PAP stain kit
Hydrochloric acid
Sperm seperation kit
Cryo prep-1 kit
Cryo wash kit
Sperm wash media
24
Unit
Unit
Unit
unit
500ml
500ml
500ml
250ml
500ml
500ml
2.5 l
125ml
100mg
500ml
100mg
500g
100g
50 g
500ml
25g
25g
125ml
500ml
5g
100ml
125ml
125ml
125ml
100g
500ml
100 ml
unit
125ml
25test/kit
10test/kit
10test/kit
136
a)
b)
c)
d)
e)
f)
g)
h)
i)
j)
k)
l)
m)
n)
o)
p)
q)
r)
s)
t)
137
138
a)
b)
c)
d)
e)
139
a)
b)
c)
140
141
AIA- 360 by TOSOH
FT3
FT4
T3
T4
TSH
LH
FSH
AFP
CEA
BHCG
CA125
Eastrogen
Prolactin
Progesterone
Diluent
Wash solution
Substrate
Standard cups
Ethanol
Sample cups
Controls- trilevel standard company – human serum assayed immunoassay and
TDM control
Nephlometer – Turbox plus by Trivitron
ASO
CRP
AT-III
RA
sample cups
For semen analyzer - SQA IIC-P
Disposable capillary
Paper roll
Capillary compartment cleaning kit (solution with cleaning capillaries)
Wintrobes tubes for ESR
test tubes (small) 7x75 mm size
25
20tests/kit
20tests/kit
20tests/kit
20tests/kit
20tests/kit
20tests/kit
20tests/kit
20tests/kit
20tests/kit
20tests/kit
20tests/kit
20tests/kit
20tests/kit
20tests/kit
4x100ml
4x100ml
2x100ml
unit
500ml
20tests/kit
12x5ml
50tests/kit
50tests/kit
50tests/kit
50tests/kit
Unit
50/pack
unit
unit
unit
unit
Tender Group No. IV
List of Items for Stationery, Lines & General Items
S.No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Name of Item
Alkaline Battery Cell (all sizes including AAA)
Baby Sheet waterproof.
Bed Pan (Steel)
Bio medical waste segregation System With three compartment -Black,Yellow
and Red
Bio medical waste segregation System with Two compartment -Black,Yellow
and Red
Bleaching powder 1 kg pac k, preferably ISI Marked
Bucket plastic with cover – 25 Ltr
Carbolic Soap
Chemical treatment System (double bucket) for disinfection
Coloured Poly bags for segregation and transportation of B.M. Waste – Red,
yellow, black of sizes: (18”x 18”)
Coloured Poly bags for segregation and transportation of B.M. Waste – Red,
yellow, black of sizes: (24"X24")
Coloured Poly bags for segregation and transportation of B.M. Waste – Red,
yellow, black of sizes: (36"X36")
Dinner Set (Bone China)
Disposable Apron Plastic
Disposable Glass Thermocol, 250ml
Disposable Spoon
Dustbin foot operate (Plastic) – Small (10Ltr)
Dusters 24” x 24”
Electricity Extension Board with power point (15 amp.), with 15-20 feet wire
(wooden) ,heavy duty
Electronic Platform model weighing Machine (iron made) for use in Bio Medical
Waste with sliding ramp on 4 sides for trolley. With printer
Foot Rest (LLDPE Material) 12" (L) x 18"(B) x 9" (H), tapper to front 3", Front
height 6", Light weight, Unbreakable, Washable, Rust free, Maintenance free,
durable material
Glass Tumbler 200 ml
Wall Clock (branded)
Weighing Machine (Ordinary)
Heat Convector ISI marked 2000 watts with thermostat
Hot case ISI Medium size
Hot Plate: - Rectangular top covered with stainless steel sheet 25 x40 x
14[10’’x16’’x6’’] fitted with on/off switch, energy regulator
Liquid Soap per ltr.
Lock size (Brass) 7 Lever Brass (50mm, 60mm, 70mm)
Multipurpose trolley –ss material with four wheel (4”) drive with HDPE pot and
HDPE lid with five colour Natural, red, yellow, blue, black.
Naphthalene balls white 500gm pack ISI Marked. (Per k g)
Oil Heater , ISI Marked
O.T. sleeper V-shape and Front Covered , sizes 6, 7, 8 & 9
Odonil air freshness 100gm
Paper Napkins 12” x 12”
Plastic Jug with lid 2.5 Ltr.
Plastic Mug 1 Ltr
Road side Bins (Rate quoted should include installation of Bins at specified
points)
Room freshener(DIFFERENT FLAVOURS)
Rubber Mat (Foot Mat) (size- small, medium & large)
Scissors (cloth cutting)
Sealing Wax (Pkt of 10 sticks)
Set of 6 cups & plates (OFFICER)
Soap case with cover
Table Glass 4 mm, margin smooth & round per sq ft.
26
Remarks
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
Tape Measure 150 cm
Tea Set (ORDINARY)
Three pin plug 5 amps & 15amps (ISI Mark )
Tissue paper Roll
Torch (2 Cells) ISI plastic (pointed white Light)
Torch Cell ISI leak proof (Size - Pencil, Medium & Large)
UPS with battery 1 KV with automatic control, with 1 hour back
Urine Pot (Male/Female)
Washing Powder (1 kg pack)
Waste paper Basket (Plastic)
Water Jugs, all sizes
Emergency Light (isi)
Hand Dryer (Double Blower)
Fly Trapper(25”L*12”H*4” 2Tube ,2 Fit Each
HT Transformer Good Quality Of PVC Cabinet)(isi)
Stand For Kipping Equipment (48”*36”*12”
Square MS Tube Pipe Powder Coating 1.5”*1.5”)
Wheeled Bins (Round and Square Shape)
ROOM HEATER (electronics) { voltage 230vs, frequency 50hz, power 2000
watt, , remote control , swing function automatic vanetimer, Safety cutoff,wall
hanging,isi mark)
Loading Trolley, Capable to take the weight up to 500KG,
Steel Benches for patients, powder coated, three seater
Disposables cans for sharp blaster sterilization unit
Disposables inserts for sharp blaster sterilization unit
Refrigerator (5star rating,branded,)
LCD TV (32”,42”)
Water Dispenser
R.O. System (12to25ltr,isi)
Floor Cleaning machine (light weight,isi)
Air Curtains
Should be Stainless Steel Body
High velocity
Ultrasonic Pest Repellers
Should have high frequency ultrasonic sound waves between
20-25 khz approx.
The should not inaudiable to the humans.
Pallet
Mobile Storage System
Work bench
Should made from M.S. powederd coated.
Should be flexible system.
Galvanished platforms with a platform load capacity of 100kg
approx
The benchtop surface should be smoothed.
Linen Items
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
Abdominal sheets all cotton 48”x 72”
Baby sheet all cotton 36”x 36”
Bed sheet, SDDMSC weaved along the length both s ides SIZE 90 inches x 60
inches (approx)
Blanket( patient )woolen
Curtain cloth for general use cotton width 54”
Curtain cloth superior for officer’s room width 54”
Doctor’s blanket woolen
Draw sheet all cotton 36”x 60”
Gynae sheets all cotton 36”x 54”with central hole of dis ered sizes
Ladies maxi stitched all cotton
Leggings all cotton Pair
O.T. Gown all cotton
O.T. Towel all cotton 36”x 36”
Patient Gown all cotton
Patient’s kurta pyagama cotton
Petticoat and jacket for female patient all cotton
27
91
92
93
94
95
96
Surgeon’s shirt and pajama (Green and colored) fine cotton
Three fold screen curtains set 54”x54”- 1Pair
Three fold screen curtains set 54”x 52”- 2Pair
Towel large 54”x 27”
Towel medium 48”x 24”
Towel small 24”x 16”
White coat full sleeve terricot
White coat half sleeve terricot
Stationery Items
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
All Pin Cushion
All Pins
Attendance Register
Ball Pen(Blue/Red/Green)
Board Pin(Classic)
Calculator (10 Digits desktop, Dual Power with memory function, big digits with
review facility for 100 and correction facility
Carbon Paper (Black/Blue) all sizes
Cartage for HP Laser Jet P 1505
Cartage for HP Ink Jet 860
Cartage for Toshiba Photocopier E-Studio 352
Cartage for SAMSUNG Fax SF-560-R
CDs- Plain /rewritable
Cello Tape size ½ Inches & 1 inch
Dairy Register
Dak Pad
Date Stamp
Dispatch Register
Duplicator paper
Envelop (File s ize) Brown Plastic coated.
Eraser / Rubber
File board
File covers (name of the hospital and other particulars as desired printed on the
c over)
File wrapper
Flags (self adhesive), size 1" wide & 3" wide
Gel Pen (Blue/Red/Green)
Glue Stick, 15gms
GPF Pass Book
Gum bottle 700ml big
High Lighter Pen
Ink for stamp pad
Marker Pen
Note sheet (best quality)
Numbering Machine
Paper Tray
Paper weight
Pen Stand- (2 pens)
Pencil HB
Pen Drive ( 2&4GB)
Peon Book
Permanent Marker Branded
Photocopy paper (size-A4) 75GSM & ISI.
Photocopy paper (size- A3) 75GSM & ISI.
Photocopy paper (size- FS) 75GSM & ISI
Pilot Pin (Blue/Red/Green)
Plain register (2 Qr)
Plain register (4 Qr)
Plain register (6 Qr)
Plain register (8 Qr)
Plastic file folder
28
141
142
143
144
145
146
147
148
149
150
151
152
153
154
Punching Machine-single
Punching Machine-double
Short Hand Book
Scale (12”)
Stamp Pad (Small)
Stapler (Big)
Stapler (Small)
Stapler pin (Big)
Stapler pin (Small)
Stock Register
Suan (Pointed punch)
Tags Cotton (bundal)
Typing Paper
U Clip
White envelop (4” X 6”) per 1000
White envelop (4” X 9”), per 100
White envelop ( A-4) per 1000
White fluid with diluter
Writing pad
29
Tender Group No. V
Anesthesia & Critical Care
S.No.
1.
2.
(CONSUMABLE OF EQUIPMENT, IF ANY MAY BE QUOTED SEPARATELY)
Name of Equipment
Specifications
MULTIPARA MONITOR
Should have following specifications ;
 High Resolution TFT display
 Size should be 7 to 8 inches
 Built in rechargeable battery
 User friendly operational window
 60 seconds full disclosure of ECG playpack
 Digital SpO2 even for low perfusion states
 Protection against artifacts
 Wireless communication with central monitoring system
 Isolation against defibrillation defect
 5 lead ECG ,Resp., Digital SpO2,NIBP,Temp.
 Light Weight approx. 4Kgs.
DEFIBRILLATOR
Should have following specifications



3.
O.T. & ICU MONITOR
4.
DESKTOP PULSE OXIMETER
The unit should be portable easy to use lightweight.
Weight of the machine should not exceeding 5 kg.
The unit should be based on biphasic technology up to
360 J.
 The unit should have both synchronous/Asynchronous
mode.
 The unit should have both adult and pediatric paddies.
 The charging time should be less than 6 sec up to 200 J.
 The unit should have facility to display six lead ECG with
heart rate alarm limit is from 30-300 bpm.
 The unit should have inbuilt thermal printer with a sweep
speed of 25/50 shocks on battery or 2 Hours of
monitoring.
 It should have integrated high resolution 5” LCD monitor
for display of 6 lead ECG.
 It should have data storage for internal ECG & voice
recording for at least 48 Hrs which can be later reviewed
on a computer.
 The unit should be supplied with complete a accessories
i.e ECG cable user’s manual and 5 packet of ECG
Electrodes.
Should have ;
 High Resolution TFT display & size should be 10.4
inches and 15 inches
 5 lead ECG waveform display
 ST analysis, arrhythmia analysis
 Digital SpO2 even for low perfusion cases
 Network capacity to connect with CNS
 72 hour tabular and graphic trend and data storage
 Standard parameters :ECG,
Resp.,NIBP,EtCO2.IBP,SpO2,Temp.
 Upgradability
for
thermal
recorder
,multigas
{CO2,O2,N2O,5AA} and Cardiac output
Should be;
 Portable
 Large 240 multiplied by 64 graphical display
 Good viewing angle
 Mains/battery operated
 24 hrs. trends
30
 Comprehensive alarms
Should have these specifications
 Minimum of Windows XP based system
 Online monitoring of all parameters
 Online arrhythmia detection &ST alarm without data loss
 96 hrs. trend for all parameters (graphical & tabular)
 Data transmission upto 30 meters
 Individual bed / patient information zoom facility
 Individual bed alarm priority setup with alarm lag report
 Easy printing option with any Windows XP compatible
printer
 4/8/12/16 bed alignment with different screen
configuration
 Arrhythmia analysis and recall facility
 Selection of waveform display
5.
MULTIPARAMETER WIRELESS
CENTRAL STATION FOR ICU
6.
MULTIPLE SYRINGE INFUSION
SYSTEM
Specifications should be
 Multiple infusion system for high flow rate upto 1200
ml/hr and a minimum of 0.1ml/hr
 Automatic syringe identification(10/20/50 ml for all major
Indian brands of syringes)
 Mains and battery operable.
 Pressure alarm settings should be available
 Inbuilt drug library.
 Volume & time controlled infusion
 Flow rate controlled infusion function
 Total intravenous anaesthesia infusion mode for all
anaesthesia drugs
 Patient controlled analgesia infusion
 Bolus rate upto 800ml/hr for 50/60 ml syringe
 Audible and visual alarm for syringe disengaged ,empty
syringe, occlusion etc.
7.
SYRINGE INFUSION PUMP
8.
VOLUMETRIC INFUSION PUMP
9.
BLOOD WARMERS
Should have following specifications;
 Fully microprocessor controlled which surveys all
operating and alarm parameters
 Automatic syringe identification (10/20/50 ml for all major
Indian brands)
 Inbuilt drug library
 Flow rate selectable for 20 ml- max. 400 ml/hr. and for
50/60 ml- max. of 600ml/hr.
 Bolus upto 999 ml/hr for 50/60 ml syringe
 User friendly single knob operation
 Mains cum battery operation
 LCD Display
 Infusion should be programmed in rate(ml/hr.) or
time(secs.)
 Audiovisual alarm indication for syringe disengagement,
drive disengagement, empty syringe, occlusion)
Should have
 Flow setting 1-1000 ml per hour
 Dose calculation feature

Alarms for error with LED light & buzzer

Having battery backup and status of battery charge
 Should have keep vein open feature at low speed
 Peristatic pump method Purge facility i.e rapid flow volume
 Alarm for bubble, tube clog,
 Door open, flow error , low voltage
 Power supply 220-240 volts
 It should have microprocessor control.
31



10.
BIPAP MACHINE
11.
OPERATION THEATRE TABLE
12
Fluid Warming System
13.
OXYGEN CONCENTRATORS
Dry heat rapid warmer
Large bright LED display for easy view from distance
Low and high temperature alarms with auto shut off at
400
 Temperature setting should be from 370 C to 410 C in
steps of 0.50 C.
 It should have mounting clamp for vertical and horizontal
operations
 Multiple temperature censors
 It should have warmer sleeve from exit of warmer to
patient
Accessories
 Extension set approx 45 Centimeter with or without air
bubbles tracks with two lver lock connectors
 Reusable silicon temperature insulation tubing
 It should be CE certified.
Should have;
 Bi Level Spontaneous mode of operation
 I-PAP and EPAP
 IPAP: 4 cm H20 to 25 cm H2O
EPAP: 4 cm H2O to 25 cm H2O
 Starting Ramp Pressure 4 cm H2O to EPAP level
 Ramp Time
0 to 45 minutes (5-minute increments)
 It should have reusable pollen filters,
 LCD keypad
 Should be provided with inbuilt humidifier
 should be CE certified
Should have following specifications ;
 Table Top
 UP-Down movement
 Lateral tilt -200 Both Sides
 Kidney section up -150mm

Trendelenberg position 300
 Reverse Trendelenberg Position- 200
 Back Section refraction- 80-up/15 down
With standard accessories
 Anesthesia screen-1
 Shoulder Support 2
 Lateral Supports -2
 Arm Rest -1
 Kneee Crutches -2
 Arm Board Radiolucent Top-1
 Remote Control Handswith-1
1. It should provide sufficient space for infusion bottles of
500/1000 ml. It should have capacity of 18-32 bottles.
2. It should have warmth insulation having energy saving
qualities and temperature stability.
3. The drawers dimension should approx 23 x 42x 28 cm.
4. It should have two drawers of dimension each.
5. Electronic and mechanical devices to prevent
overheating.
6. It should have key switch for system test .
7. plastic laminated insulation plates, transport handle, four
castors with wheel brakes
8. Drawers should have Metal extension, automatic closing,
alarm signal when the door is open
Should have following;
 Dimensions 27.5 in.Hx 16.5 in. W x 14.5in. D
 24.5 kg weight
 ALARMS - Power failure, high and low pressure,
32
14.
OXYGEN PRESSURE
REGULATOR
15.
16.
ULTRASONIC NEBULISER
PATIENT WARMING SYSTEM
17.
DIGITAL THERMOMETER
18.
PHARMACEUTICAL
REFRIGERATOR
19.
OPERATION THEATRE SCRUB
STATION
temperature, battery test, low purity test(with optical
oxygen monitor)
 PERFORMANCE –
 LPM
Concentration
1-3
95%±3%
4
92%±3%
5
90%±3%
 Should be based on atmospheric pressure of 101 kPa at
70ºF(21ºC)
 Should be CE Certified
Should be;
 2 STAGE with FLOWMETER and FLOW RATE
 For B type and D type cylinders
Heavy duty and should come with stand /trolley
The system consisting of following specifications:
 Intended for use in pre operative, peri operative and
post operative care in OT,. Recovery rooms ,ICU and
wards.
 It should have multiple independent working temperature
sensors on all heating elements
 Large temperature and alarm LEDs to view from
distance.
 High temperature alarm with auto shut-off at 42 degree
Centigrade
 Detection and display of errors and alarms in case of
malfunction
 Preset temperature at 37 degree for neonates and 39
degree for paed. Which can be changed
 Compatible with Matress or Blankets.
 All mattresses to be equipped with pressure relief foam.
 Blankets made of soft, light weight and flexible textiles to
cover patient body.
 Facility to warm 2 patients with one Monitor.
Should be
 having both Celsius and Fahrenheit scales
 Auto switch off facility
 Washable
 Suitable for oral as well as axillary measurement
( i) 330 Ltrs
(ii) 465 Ltrs.
Should have drawers/ shelves
Should have cross flow blowers
Should have fully automatic temperature controls.
Should not be effected by ambient changes
Insulation should be not less than 55mm in any case
Door should essentially be solid door.
Should have a 365 days temperature & humidity recorder
paperless
Should be supplied with Voltage stabiliser.
It should be fabricated from heavy gauge preferably type 304
SS, seamlessly welded and polished to a satin finish, designed to
be installed on a wall using mounting carriers with removable
front access panel for access to the water control valves, waste
connection, stops and strainers., sloping bottom surface to
minimize splashing and a tail piece with flat strainer drain,
infrared sensor with built in adjustment for Hands free operation
along with elbow action & knee action taps. thermostatically
mixing valve control for constant water temperature.
It should have user definable settings for different time periods.
It is provided with soap dispensers and canceled hanger
33
20.
ECG PLUS AED DEFIBRILLATOR
21.
PATIENT TRANSFER TROLLY
(Hydraulic)
22.
AUTOMATIC SHOE COVER
DISPENSER
23.
AUTOMATIC SHOE COVER
REMOVER
brackets.
Should have
 3 Channel ECG machine with LCD Display
 12 lead resting ECG with interpretation and thrombolysis
software
 With integrated biphasic defibrillator technology
 Light weight upto 3 Kg and supplied with 10 lead ECG
cable facility to enter patient data
 Should be an AED mode
Unit should be made of epoxy poweder coated M.S. and
should have the overall size 210 L x 74 Wcm Siderail up- 120 L
x 37 H cm,. Positioning should be Backrest- 0 to 90 degree (dual
air spring), Knee Gatch- 0 to 40 degree (crank), Height
adjustment range- 35 cm
(hydraulic pump), Trend./Reverse
Trendburg,
(e) Foot Position Lever- 0 to 15 degree
(manual),side rail should be foldable with safety lock, Chest Xray platform,e. 5th wheel , Folding driving handle x 2PCs
Name card holder x 1PC, h. Reverse oxygen holder x
1PC,
Restraint strap loop x 5PCs/side
CasteI(J central braking and steering system with head and
foot pedal and Mattress should
be at least 40 density, Hospital grade radiolucent mattress,
constructed of flame retardant material
with antimicrobial agents. And Covered with material
resistant to blood, urine and chemical stains
a. Dimension:
(a) Overall – 210 L x 74 Wcm
(b) Sleeping surface – 190 L x 64 Wcm
(c) Siderail up- 120 L x 37 Hcm
b. Positioning:
(a) Backrest- 0 to 90 degree (dual air spring)
(b) Knee Gatch- 0 to 40 degree (crank)
(c) Height adjustment range- 35 cm
(hydraulic pump)
(d) Trend./Reverse Trend.- ±18 degree
(hydraulic pump)
(e) Foot Position Lever- 0 to 15 degree (manual)
c. Side-rail:foldable with safety lock
d. Chest X-ray platform
e. 5th wheel
f. Folding driving handle x 2PCs
g. Name card holder x 1PC
h. Reverse oxygen holder x 1PC
i.
Restraint strap loop x 5PCs/side
j.
Caster:8” central braking and steering system with
head and foot pedal
Automatic shoe cover Remover
It should have digital display for the shoe covers
The dimensions should be
H - 70-80 cm
W - 30-35cm
L - 95-105cm
Should have capacity to hold min. 100 covers
Should be easy to operate
Should be operable on 220V
Empty weight should not be more than 35Kgs.
Should not consume more than 50W of electricity
34
24.
ADULT ACLS TORSO WITH
INTERACTIVE ARRHYTHMIA
SIMULATOR
25.
GLUCOMETER
Product should be CE marked
ISO company will be given preference.
 Should allow wide range of ACLS training possibilities
including arrhythmia recognition & confirmable
defibrillation
 Should be supplied with storage case
 Should have palpable & visual landmarks
 Fully articulated head neck & jaw
 Realistic anatomy of the mouth ,tongue, oral pharynx,
larynx,epiglottis,vocal cords,trchea,oesophagus
 Cricoids cartilage allows for practice of sellick manoeuvre
 Separate left & right lungs for auscultation
 Oral ,nasl,digital intubation facilities
 Suctioning capabilities
 Internal load box absorbs full strength of every shock
 Manual ,semi automatic, automatic defibrillation
 Monitor manikin like a real patient at 4 ECG sites & 2
defibrillation sites
 Compatible with all standard brands & types of
defibrillators


26.
OXYGEN CYLINDERS
27.
28.
30.
NITROUS OXIDE CYLINDERS
SPINDLE KEY FOR GAS
CYLINDERS
CYLINDER
STAND
WITH
WHEELS FOR A and B TYPE and
D TYPE CYLINDERS
HAEMOGLOBINOMETER
31.
AUTOCLAVE(HORIZONTAL)
29.
Should be able to measure glucose from small drop of
blood obtained by pricking the skin
disposable test strip, which the meter reads and uses to
calculate the blood glucose level.
Test strip should be shelf life of at least 2 year
The meter should display the level in mg/dl and mmol/l.
A Type
B Type
D Type





A Type
should be made of good quality metal
should be provided with antistatic wheels
Should have
 capability to measure venous, arterial or capillary samples
 capability to measure all clinically relevant haemoglobin
species and haematocrit.
 Measuring time should be less than 90 sec.
 should be fast and accurate
 Measure unit g/dl, or mmol/l (selectable)
 Reading error - 5% max
 calculation should be based on the principle of absorption
photometry
 capacity to store at least 100 results with date and time
 should be battery operable in case of power failure
 light weight
 should be operable at room temperature
 samples should be able to taken in microcuvettes with store
/shelf life of at least 2 years at the time of supply
 supplier should give undertaking of providing microcuvettes
on short notice in case of shortage
Should be ISI Mark
Should be hydraulically tested to withstand 2.5 times the working
pressure.
Chamber, Jacket, Steam generator, outer cover should be made
of 304 grade SS. Should be Triple walled with steam jacket and
separate boiler Inner chamber and steam jacket should be of
35
32.
ENDOTRACHEAL TUBE CUFF
PRESSURE MONITOR
33.
34
Resuable LMA
MANUAL SUCTION UNIT
35
HIGH VACCUUM SUCTION UNITS
36
BLOOD GAS ANALYSER
Heavy gauge S.S. Sheet with leak proff argon-arc welding.
Should have single piece door made of steel plate lined with S.S.
from inside and back plate and ring should also made of thick
stainless steel sheet. Door should have grooves to hold EPDM or
silicon gasket to ensure leak proof locking. Door should have
hinged self locking single piece thick steel plate lined with S.S.
from inside door and should not open under pressure. Should
have self locking automatically engaging devise with clutch
mechanism to avoid opening of the door when chamber is
pressurized. Sterlizer should be mounted on tubular steel frame
duly powder coated with ground leveling screwed flanges. The
Outer jacket should have insulation material & should be covered
by steam polished stainless steel sheet. Steam generator should
be made of heavy stainless steel sheet with minimum joints and
bolted parts. Should be fitted with suitable capacity heating
elements and low water level cutoff system, gauge glass
assembly with shut off valves for water level indication, water
inlet & outlet valves. Heater plate should have a hole for easy
cleaning of the deposited scale. Should be fitted with pressure
control device. Complete Sterilizer cycle should be controlled
from one point with the help of multiport valve. Should have two
speeds of steam exhaust. Drying of the sterilized load should
also be done with the help of powerful ejectors.
Switch Box should have main switch , pilot lamps, relays etc. and
mounted on the stand of the sterilizer for easy operation.
The sterilizer is provided with the triple safety features
functioning independently & should back each other. A
removable plug screen should be provided to prevent the
discharge line from choking. Should have digital temperature
controller with time that raises an alarm at a set time. Should
have Automatic water feed system.
Sterilizing Temp : 121 ºC
Sterilizing Pressure : 1.2 to 1.5 kg/cm2(15 psi to 22psi)
Power Requirement : Suitable to operate on 440Vvolts, 3 ph, 50
Hz, Ac Supply
Should be ;
 Portable
 Light weight
 Calibration in mmHg (0 to 90)and cm of water(0to120)
Should be re-useable silicon flexible laryngeal mask reinforced.
Should be ;
 Manually operable with single hand
 Vacuum 450 mm Hg
 Having two containers of 250 ml with two different use
catheters.
- Housing should be made of Plastic Moulding (Rust
Free).
- Suction Capacity should be -700mm Hg+/-10 regulable,
Flutter free vacuum control knob, have option of
selecting 30Ltr/hr to 60Ltr/hr & vice-versa at the press of
a button.
- Twin Double diaphragm & lubrication free pump. Double
overflow protection i.e; manual overflow device & electric
shutoff on overflow.
- Wide mouthed 2x2Ltrs PC Jars with self sealing bungs
with overflow safety device.
- Bourden type vacuum gauge 0 – 760mm Hg (also
kg/cm2) Calibration.
- Power 230V, 50 Hz +/-0.5 Amps, 430 watts.
- Noise Level 50dB A+/-3
- C.E & ISI Approved.
Should be
36












37
Air Purification
System
&
Fumigation
38
WRIGHT’S PEAK FLOWMETER
39
BP APPARATUS
40
NEEDLE CUM SYRINGE
DESTROYER
41
Percutaneous Neuromodulation
Pain Therapy System
Fully automatic,fast and microprocessor based/computer
controlled of reputed brand.
Should provide an all inclusive test menu offering at least the
following parameters pO2,pCO2,Ph,H+,Hct,Hb,
Na+,K+,Ca2+,Cl2+,Glucose,Lactate, standardHCO3,actual
HCO3,BEecf,BEB,Anion gap, tCO2, O2 Sat,O2 Content , P50.
Automatic calibration and washing.
On screen display of results and in built Printer and memory.
Results should be available in a maximum of 60 secs.
Availability of separate bottles/bags for washing and
calibration gas/solutions
Should have economy mode with extended calibration
interval to reduce the reagents consumption.
Electrodes should have long life with guaranteed durability
of at least three years each. guarantee certificate about the
life of electrodes from the original manufacturer should be
attached
On board life,i.e stability of reagents after opening reagent
bottle must be a minimum of 90 days.
All the brochures /literature/catalogue must be provided by
the supplier/firm to support the specifications claimed to be
present in the equipment.
UPS and CVT of required rating should be provided.
Firm should ensure real time demonstration of the equipment
put up for tender.
– Air Purification System for killing Bacteria and fungus,
for deodorize the air and stop regeneration of bacteria.
– Should have user selectable program for fumigation and
purification modes.
– Should have four-stage mechanical filtration to trap
99.97% particles up to 0.3 microns.
– Should have Activated carbon filter to remove odors and
volatile organic compounds.
– It should use ozone gas shock treatment for fumigation.
The ozonation period
should be user programmable
with a provision for minimum 8 programs for 7 days in
advance.
– It should have maintenance of air purification by Ultra
Violet Germicidal Irradiation technique at 254nm.
– Should have High Efficiency Particulate Arrester Filter
with its life monitor.
– The machine should be programmable for 7 days and
minimum 8 options /day.
– The System should be wall mounted for maximum air
purification.
– The maximum area recommended for one should be
4000 cubic feet.
– It should be manufactured by ISO,GMP and WHO
certified company
Should be
 6 Inch dial
 Well mounted with extension tube
 Should be provided with cuffs of all sizes
Equipment to destroy syringe & needle both in single action
without use of battery or Electric Power. The cut hub & needle
should fall in sharp containers made up of bio-degradable &
Autoclavable material having minimum 2Ltrs Capacity.
The equipment should
1. Should be be microprocessor based system capable of
delivering output through
37
Percutaneous electrode Array ( 1.5’’ diameter microneedle array
within 2.5”
diameter hydrogel-based sterile electrode.
2. Should have signal output through two feed electrodes (Feed
frequency 1: 3858 Hz, Feed
Frequency 2: 3980 Hz) .
3. Should have voltage range : 0-27.5 V rms & waveform should
be sum of 2 sinewaves.
4. Should have power source 12 V DC, 3850 mAh rechargeable
NiMH internal battery.
5. Should have compatibility with following accessories
5a. Percutaneous electrode Array having 1000 microneedles
0.74 mm (
1.5’’ diameter microneedle array within 2.5” diameter hydrogelbased
sterile electrode.
5b. Surface feed electrodes of various sizes (2” x 4” and 5” x 8”).
42
ENDOTRACHEAL TUBE
CUFF MANOMETER
Hand pressure guage, for intra cuff pressure monitoring. Should
be able to inflate or deflate cuff as per requirement and form an
adequate seal and safe cuff pressure. Calibrated in cm h2o, fitted
with clip attachment, for intra cuff pressure monitoring. Additional
extension cord supplied with the instrument
43
REVOLVING STOOL
44
DRIP STAND
45.
ANAESTHETIST CHAIR
46.
KICK BUCKET
47.
Foot STEP STOOL (Single and
Double)
ANATOMICAL FACE
MASKS(RUBBER & SILICON)
Should be
 Height adjustable 41 to 56cms.
 Stainless steel top with pneumatic height adjustment
 Moulded five pronged mobile base with 5cms. Swivel
twin castors
Should be
 Height Adjustable 136 to 240 cms.
 Stainless steel outer tube
 Stainless steel pole with 4 hooks
 Moulded five pronged mobile base with 5 cms swivel
twin castors
Should be
 Height adjustable 43 to 58 cms.
 Cushioned seat & back with pneumatic height
adjustment
 Moulded five pronged mobile base with 5 cms. Swivel
twin castors
 Provided with a foot ring
Should have
 Three swivel castors
 Stainless steel frame
 Deep container
 All round bumper
Should have Power epoxy finish with aluminium treads for grip
48.
49.
50.
RINDAL BAKER SAUCHEK
MASKS
PAEDIATRIC LARYNGOSCOPE
(Paeds & Adult)
 Sizes 0 to 5
 Should be reprocessable and air cushioned type
 Optional- scented silicon masks
should be made of antistatic material
Set containing:
1. Laryngoscope Blade
laryngoscope blade(s) with specially designed view
tube allowing vision of 42 degree from straight line of
sight,
 two sizes of blades available, small mouth and
standard mouth
38








integral oxygen supply tube allows extension of
intubation time,
easy link up to Endoscopic systems provided
blade containing replaceable fibre-optic element,
Replaceable fiber clip for easy cleaning.
Stainless steel , fibre-optic blades that complies with
Green System (ISO 7376(iii) compatible) handles
blade that fits on to International standard ISO
compatible handle,
all contact points between blade and handle must be
of stainless steel.
Production batch number must appear on blade
a. Optishape Stylet

Re-usable stainless steel stylets, two sizes (pediatric
& Adult) with patented ideal shape .
b. Handle
 Xenon bulb with gold plated housing and contacts
with light output in excess of 2,800 Lux.
 Must hear click when blade is engaged onto handle
to protect against faulty placing of blade
 Handle components of electrical system must be
manufactured from stainless steel to prevent
corrosion
 Handle conform to international standard ISO
7376(iii)
51.
52
Fan Holder For Endotracheal Tube
And Anaesthesia Circuit
Anesthesia Trolley
53
AMBU BAG WITH RESERVOIR
BAG
54
LARYNGEAL MASK AIRWAY
CLASSIC
55
LARYNGEAL MASK AIRWAY
PROSEAL
56
INTUBATING LARYNGEAL
MASK AIRWAY
Unit should have high density resin / ABS framework, slide out
writing surface, Hard surface plastic table top. Drawers of
different configuration 3” , 6” 9” etc. with lock for keeping different
items.
Should be
 100% latex free
 Air intake valve with integrated oxygen reservoir bag

360º rotatable patient valve which can be easily
assembled and disassembled
 Should be available in adult/paediatric /neonatal models
Should be
 Reusable ,upto 40 times autoclavable
 Made of medical grade silicon
 Separate inflation line
 Should have aperture valves to prevent obstruction by
epiglottis
 Should be available in sizes 1 / 1.5/ 2/2.5/ 3.0 /4 /5/ 6
 Cuff deflator for all sizes should be supplied
Should be
 Made from medical grade silicon
 Should be reusable ,autoclavable at 135ºC
 Built in bite block
 Shold be supplied with an introducer,insertion strap
 Gastric port shold be compatible with 14 G ryles tube
 Should be available in sizes 1.5 ,2 2.5 ,3,4,5,
 Should be supplied with cuff deflaters
Should be
 Made from medical grade silicon
 Should be reusable ,autoclavable at 135ºC
 SHOLD BE SUPPLIED with a 15 mm connecter
39



Sizes 3,4,5
Should be supplied with silicon ,soft ,wire reinforced
,cuffed ETT of 7.0 ,7.5 8mm internal diameter
Should have stabilization rod of 20 cm
57
EO STERILIZER
Should be
 Automatic microprocessor controlled
 Should have LCD display of cycle process i.e
temperature,pressure,relative humidity in %,current
phase, set values with context to time
 Size should be at least 4 ft x 1 ft
 Horizontal stand alone unit constructed from high grade
ss material with radial arm door locking unit
 Should be capable of operating with both 100% EO
Cartridges and EO:CO2 cylinder
 Puncturing of the 100% EO cartridge should be
automatic
 Should have in built steam generator for humidification.
 The system should have remote monitoring and
controlling software. The software has to be installed in
the computer provided by the manufacturer for the
purpose.
 It should give visual printed records in following formats.
1 Graph
2 Summary
3 Detailed data
 Rates of accessories , including 100% EO catridge is to
be quoted
58
MAGILL FORCEPS
Should be made of S.S.
59
ISI Marked and should be made of SS.
60
DRUMS FOR AUTOCLAVE
MADE OF STAINLESS STEEL
BOTH BIG &SMALL SIZES
FORMALIN CHAMBERS
61.
MULTIUTILITY CART
62.
SPHYGNOMANOMETER
63.
INCUBATOR FOR BIOLOGIC
INDICATORS
64.
SEALING MACHINE
65.
SYSTEM FOR THE TREATMENT
Three Trays
20” X 8” X8”
 Should have rail mounted drawers,atleast 10 in no.,5 on
each side with trashbin on one side
 Solid base small instrument case on other side
 Should have stainless steel cage on top for for placing
drugs and IV rod
 Writing base provision
 Should have provision for electrical connections & inbuilt
power station
 Should be shock proof & shock absorbing polyamide
housing latex free &push button air release valve.
 Fine & precise air release rate adjustment
 Ultrafast on release
 Practically wear free
Autoreader ,self calibrating,to read rapid attest BI with twelve
incubation wells ,each well with a red green & yellow light
For ease of interpretation of positive BI readout time should be 1
hr.,3hr., 4hrs. by a visual red light & an audible alarm
Should be
 Basic sealer for packaging of medical products
 Rotary sealing machine in coated metal housing white
varnish, without starting atomization for packaging
transport
 Sealing speed should be 10 m /min, digital temp.
control,230 V
Using surface bonded long lasting non-leaching antimicrobial
40
OF VARIOUS SURFACES
66.
FUMIGATION MACHINE
67.
Anesthesia Machine
treatment.
Chemical for the system:
Should have broad-spectrum microbicidal molecule.
Should be non-volatile non migrating material with a unique
surface modifying technology to impart safe & lasting
antimicrobial activity to treated surfaces.
Shouldn’t contain arsenic heavy metals or polychlorinated
phenols.

Multipurpose, heavy-duty portable fumigation machine
capable of producing aerosols with particle size of less then 5
microns, for use in critical and semi critical areas of hospital.
 Body should be compact, durable, leak proof and made of
stainless steel/heavy duty plastic. The blower head should be
rust proof and deliver aerosols uniformly.
 Machine should be compatible with all disinfectant solutions
containing sliver nitrate, hydrogen peroxide in usual
concentration. Machine should be compatible with maximum
ph range (both acid and alkali).
 The tank capacity should be 4-6 liters, with easy cleaning
facility.
 The machine should operate on 220 +- 10 Volts, 50Hz, single
phase, A.C supply commonly used in Indian conditions
 The discharge rate should not be less than 1 Liter/25 minutes.
 The tank capacity, discharge rate and timer on the machine
should be so that the disinfectant should be able to disinfect
4000-5000 cubic feet in one cycle of 2 hours (max).
 The equipment should be of good quality and conform to
national/international standards.
 Machine should be user friendly and have safety features
 Cable should be at least 5 meters in length, ISI marked.
 Company should be able to demonstrate and train users on
proper usage of the fumigation machine in the user areas
 The company should ISO or equivalent certified.
1.The Unit should have for the following gases - Oxygen,
Nitrous Oxide and Air,
1. Low Flow Rotameter for Oxygen, Nitrous Oxide & Air,
2. Mechanical Anti Hypoxic Device with audio visual alarm
with Propotionating device for
3. oxygen and nitrous oxide (link system)
4. Audio visual alarm for Oxygen Failure,
5. On/Off Switch with Basal Flow,
6. Backlit Rotameter,
7. Nitrous cut off in case of oxygen failure.
8. Airway pressure monitoring with audiovisual alarms
during ventilator use
9. Ventilator bellows with gradations of 100 cc onwards
10. Auxiliary oxygen outlet.
11. Emergency oxygen flush
12. Pipeline Inlets for Oxygen, Nitrous Oxide, and Air,(DISS
Compatible)
13. Cylinder Yokes for Oxygen(2) and Nitrous(1) Oxide with
pin index,
14. 2 Deep Spaced Drawers,
15. Integrated Circle Absorber with On/Off and Bag-Vent
switches,
16. Oxygen Sensor port.
17. It should have common gas outlet ISO standard taper
and suitable for Open, semi
18. it should have open and closed circuit system.
19. Patient safety blow off valve if pressure> 50 cm H2O
20. In built drug and instrument tray on front portion of the
41
machine for anaesthesia drug and instrument
21. it should have the facility to mount a minimum of two
vaporizers.
22. it should be CE marked
68
Vaporizer
69
Examinations Hammers
1. It should have high precise vaporizers. It has scope of
concentration regulation.
2. Calibration range 0 to 5%. It should have interlock
mechanism to lock in series with other vaporizers.
3. Easy to turn dials for safety locks to prevent accidental
turn on.
4. CE marked.
Should be of good make and quality
70
106 Nylon filaments
Should be of soft texture
71
O.T. Bottle Holder
Should fit into any hand disinfectant bottle of standard quality
72
Hand Rub Dispenser pump
should be compatible with all standard hand rub solution bottles
73
SWAB RACK /STAND
74
HUMIDIFIER FOR BIPAP
Should made of S.S.
Overall size approx 137 h x 76 w x 46 D cms
Should have frame work of s.s. Tubes mounted on 10 cms dia
castor.
Should Have Eight Rows With Six Hooks In Each Row.
Should have S.S. Tray fitted on bottom side
Should be compatible with standard BIPAP machines &
should function as inbuilt humidifier
75
Emergency First Kit
with respiratory Care Equipment
42
LIST OF CONSUMABLES FOR DEPARTMENT OF ANAESTHESIA
S.No.
1.
2.
3.
4
Name of Item
Wooden disposable tongue depressor
Disposable plastic apron
Disposable Cap and Mask
Face mask with anti fogging shield
5.
6.
Antifog Safety goggles
OT wear kit (HIV)
7.
8.
9.
10.
11.
Antimicrobial hand cleaning lotion
Antimicrobial skin cleanser
IV cannula
IV and CVP dressing
Transparent dressing pads
12.
Surgical Tape
13.
14.
15.
IV Drip Set
Three Way Stop Cock
IV extension Tubing
16.
17.
18.
Measured Volume Set
Blood Transfusion Set
ECG electrodes
19.
20.
ECG Jelly
Ryles Tube
21.
22.
23.
24.
25.
26.
Suction Catheters
Foley catheter
Urobags
Bains Circuits
HME filter
Patient Connectors
27.
28.
Endotractal tube with suction canula
Airway
29.
30.
31.
Endotractal tube with Bite Blocks
Dental Guard
Nasal Oxygen Catheter
Specifications
should be good quality
It should be Knee length
Double, non-woven cloth
Double, non-woven cloth, malleable, smooth, nasal clip, strips
and adequate length
Eye shield or goggles double layers double fold
Single Doctor kit – should be made of water repellent spun
less fabric containing
Facemask 3 layers with filter
Hood cap
Long shoe cover up to knee
Gloves double high quality with change of Colour after
puncture
Gown one with internal lining in front and the sleeves
Eye shield or goggles double layers double fold
Double, non-woven cloth, malleable, smooth, nasal clip, strips
and adequate length
Should be ISI marked
Should be ISI marked
Should be with injection port and wings. (all gauges)
Should be transparent dressing tape.
Should be transparent and absorbent dressing pads. Sizes –
5x7, 9x15, 9x25, 9x35, 9x10
Should be soft cloth surgical tape. It should be hypoallergic,
latex free directional tear surgical tape with 0.5, 1, 2, 3, 4, 5
inches
Should be presterilized. And ISO certified.
Should be ISO certified.
Should be with three way stop cock., high pressure resistant
low volume spirally coiled 200cm and should be ISO certified.
Should be 100 cc with 10 ml overflow and flow controller.
Should be with filter chamber and ISO certified.
Should be disposable and standard size with button preferably
with loc system
Bottle of 250 ml.
Ryles tube with distal end coned with SS balls, 4 lateral eyes,
radioopaque line all sizes.
Should be thumb operable and ET tube compatible all sizes.
Should be silicone / rubber, all sizes, perefrbly ISO certified.
Should be disposable with sample port.
Should be disposable with APL valve.
Should be anti bacterial and anti viral.
It should be straight/ angled/ Y-piece/ T-pieces. It should be 22
mm , male-male, male-female, male, female.
Guedels
 It should be with bite block with color code size
000,00,0,1,2,3,4,5
Nasopharyngeal
 size should be 5,5,6,6.5,7
It should be straight, curved flared and curved flared prong.
43
32.
Oxygen Masks
33.
Venturi Valves
34.
Aerosol therapy mask
35.
T-Pieces
36.
37.
Anti Fog Solution
Trachlight Set
38.
Endotracheal Tube
39.
40.
41.
42.
HYPODERMIC NEEDLES
Combitube
Endotracheal tube fixers
Intubating Stylets
43.
44.
45.
46.
47.
Nebuliser kit
Circle Breathing system
Carbon Di Oxide Absorbants
Breathing Tube extension
Breathing System T- piece
48.
49.
50.
Bains Breathing System
Disposable Spinal Drape
Spinal Needles
51.
52.
Epidural catheter set
CSE set
53.
Epidural Catheter extension
54.
Epidural Needle With Catheter Set
55.
56.
57.
58.
59.
60.
Cricothyrotomy Sets
Percutaneous Tracheostomy set
Tracheostomy Set
Central Venous lines
Arterial Cannula
Syringes
61
Needleless Syringes
62
63
Disposable Needles
Urine pot
64
65
66
67
68
69
Bed Side Commode
Bed Side chair Commoede
Steam Inhalation kit
Incentive spirometer kit
Adult Diapers
Endotracheal Intubation set
Oxygen masks should be with nose clip and oxygen tube. It
should be adult and paediatric sizes.
It should be silicone made ranule valves and ranule mask
kit , modular ranule valves, direct ventury valve mask kits,
adult ventury kit and oxygen recovery kit.
It should be modular with small, adult, paediatric with and
without nose clip.
It should be made of silicone and modular, preferably ISO
certified.
It should be of good quality, clear sight, single use.
Trachlight set illuminating stylet. It should be in all sizes with
separate handle and light wand
It should be cuffed and non cuffed in all sizes including
flexometallic.
All sizes(27G to 16 G)
It should be in all sizes.
It should be made of silicone and ISO certified.
It should be malleable sheathed intubating stylets in all sizes.
It should be adult and paediatric.
It should be made of silicone and ISO certified
It should be of good quality and in shape of granules.
It should be made of silicone and should be transparent
It should be t-pieces breathing system in infant size.
(Mapleson F)
Bains breathing system with inner lumen leak tester.
It should be disposable spinal drape.
 Quinckes
o should be18,20, 22,23,24,25,26,27,28 G with
or without introducer needle.
 Whitcare
o should be 25,26 G
It should be made of silicone and ISO certified
should be of good quality and should comprise of epidural
needle,spinal needle,epidural catheter,bacterial filter and loss
of resistance syringe
It should be made of silicone extension tube for infusion of
drugs by epidural catheter.
Epidural needle touhy 16,18 G with marks at 1 cm intervals
and epidural catheter with appropriate markings
It should be cuffed.with 7.5 cm length
It is made of silicone and ISO certified
It should be in all sizes and should be disposable.
It should be double and triple lumen.
It should be with radioopaque line.
It should be disposable syringes with all sizes i.e. 10 ml, 20 ml,
50, 60 ml.
It should be non venting needleless syringes for in line
catheter use 1,3,5 CC
It should be in all gauges
It should be made of PVC with gradations showing urine
volume.
It should be made of PVC and leak proof.
It should be made of PVC and should be leak proof
It should be of good quality preferbl;y ISO certified
It should be of good quality preferbl;y ISO certified.
It should be of good quality preferbl;y ISO certified
It should contain Endotracheal tube, stylet, laryngoscope
blade, tube holder, suction catheter, suction tube, syringe 5ml,
10ml, and gloves
44
70
Spinal Set
71
Epidural Kit
72
Pressure infusion bags
73
Uristicks
74
75
76
77
BULBS FOR
LARYNGOSCOPES,ADULT
&PAEDIATRIC
LONG LINE MADE OF
POLYURETHANE MATERIAL
FOR CVP MEASUREMENT
DISINFECTANT FOR CLEARING
THE SUCTION SYSTEM
SURGICAL TAPE
78
SURGICAL TAPE (STRETCHABLE)
79
TRANSPARENT DRESSINGS
80
TEGADERM DRESSING WITH
ABSORBENT PAD
81
DRESSING WITH SOFT CLOTH
REINFORCEMENT
82
IOBAN INCISE DRAPE
It should contain swabs, gloves, sheet, small towels, spinal
needle, syringe 5 ml, 10 ml 20ml,
Epidural puncture needle, liquid medicine filter, air filter,
epidural aneathesia tube, plastic syringe, 5ml glass syringe,
needleless syringes 3 nos., tube holders two, skin brushes,
gloves, non woven fabric with hole, two gauze, dressing pad,
tampon.
 500 ml, 1000 ml, 3000 ml capacity
 Optically clear window like nylon netting for viewing
infusion fluid level
 Tested to be free of pin holes
 Visible gauge to indicate bladder pressure
It should be for protein, sugar and ketones.


Should be 16 G length 70cms. Needle through needle
technique
Should be
 Phenol &aldehyde free
 Biodegradable
 4.2 gm amidosulfonic acid
 3.28gm Na Hydrogen Phosphate,Tensides,Audiliaries
Sizes ½”,1”,2”,3” X 10 yards
Woven fabric, acetate taffeta non elastic tape with strong
tensile strength, bi directional tear-ability and high
adhesive strength for securing critical tubings and devices
 Sizes should be 2”,3”,4”, 6”,8” × 10 yards
 Hydro entangled polyester fibre, non woven porous
perforated thus breathable, water resistant, stretchable
soft cloth backing, coated with pressure sensitive
hypo-allergic acrylate adhesive.
Should have following specifications
 Single sterile, transparent, semi-permeable, water and
bacteria proof thin conformable polyurethane film;
coated with water repellant hypoallergic pressure
sensitive acrylate adhesive with unique paper window
frame delivery design.
 Sizes 6cmx7cm ; 10cmx12cm ; 10cmx25cm; 15x20cm
; 20cmx30cm
Should be ;
 Single sterile,transparent, semi-permeable,water and
bacteria proof thin conformable polyurethane film;
coated with water repellant acrylate hypoallergenic
adhesive with paper window frame delivery and having
a non adherent absorbent pad.
 Sizes - 5cmx7cm; 9cmx10cm; 9cmx15cm; 9cmx20cm;
9cmx25cm; 9cmx35cm
Should be
 Single sterile,transparent, semi-permeable,water and
bacteria proof thin conformable polyurethane film with
one half laminated with soft cloth breathable backing
for enhanced grip.
 Sizes – 5cmx5.7cm ; 8.5cmx10.5cm
 Incise drape comprised of polyester , thin breathable,
low memory iodophor impregnated film offering
gradual sustained relief for 7 hrs.
 Drape coated with pressure sensitive acrylate
adhesive
45
83
SURGICAL CLIPPER
84
85
CARTRIDGE FOR SURGICAL
CLIPPER
SURGICAL DISPOSABLE GOWN
86
HAND DISINFECTANT
87
GLUTARALDEHYDE MONITOR
88
MULTIENZYME CLEANING
SOLUTION
AUTOCLAVE INDICATOR TAPE
89
90
ETHYLENE OXIDE INDICATOR
TAPE
91
CHEMICAL INTEGRATORS-STEAM
92
BOWIE DICK TEST PACKS
93
RAPID READOUT BIOLOGICAL
INDICATORS
PATIENT PLATES
94

Surgical clipper with disposable blade assembly
operated either by battery or cord.It should be having
cutting blade position away from skin. Should be with
unique modern ergonomic design.
Should be
 Non woven 4 layered sterile,lightweight,breathable,low
linting surgical disposable gown with outer & inner
layer made of strong &spun bond repellant fabric and
two middle layers offering fluid control and bacterial
barrier.
 Sizes medium 132cms.,large 142cms.,xlarge 148
cms.,xxlarge 156cms.
Should be
 Antiseptic alcoholic slution for hand hygiene containing
2 propanol &mecetronium ethosulphate with pleasant
fragrance.
 The solution should be capable of killing micro
organism including bacteria,spores, virus, fungi &
algae
Indicator strips should check minimum effective conc. (1.5%)
of 2% glutareldehyde solution by a visual colour change
readout within 2-3 mins.
 Must act against all possible body secretions
compatible to instruments
Should be
 Heat sensitive chemical indicator self adherent tape
without leaving any adhesive residue for steam
sterilization cycles
 Colour change should be from white to dark brown for
easy identification after processed in steam autoclaves
of different time & temp. requirements within 15
minutes at 121 degree C & 3 minutes at 134 degree
C.
 Size 1/2×30 mtr. roll
Should be
 Applicable to both warm & cool temperature cycles run
at 37ºC or≥50ºC
 ¾”×55mtr. Roll
 Moving front chemical integrators should verify all
parameters of steam sterilization together i.e. time
,temp.,& quality of steam
 Read out indicates accept or reject after processing
allows to differentiate all the parameters
Should be
 Test sheet along with penetration challenge material
should be in single easy handled pack
 For steam and ETO sterilisation
Should be Disposable grounding plates for electrosurgical use, with thin conformable, tear resistant, fluid
resistant, fluid resistant, occlusive polypropylene
backing coated with thick and soft hydrophilic
conductive adhesive gel. Plate design to have
handling tabs, plate lined with transparent polyester
liner and available in split and non split versions with
both cord and without cord design for adult and
paediatric applications as a Universal size.
46
95
BASIC SURGICAL PACK
Should be
 Made from absorbent impervious material
 Should contain all contents ideal for general surgery
surgical procedures which includes hand towels table
cover, operation tape & adhesive drape sheet
 Must be sterile
 Sterile leg covers for lithotomy position
Should be ;
 Sterile adhesive strips of porous ,non woven, rayon
backing,reinforced with polyester filaments for skin
closure,coated with pressure sensitive ,hypoallergic
acrylate adhesive
 Sizes 6mm×100mm,12mm×100mm,25mmx125mm
 Heat sealable sterilization packaging material of
medical grade paper on one side & laminate of
polyesters &polypropylene on the other for both steam
& EO sterilization
 Packaging material has its chemical process indicators
for both ETO &steam sterilization process printed on
paper side to allow the differentiation between
processed &unprocessed packages
 Should be available in 10 commonly used sizes
should come in all adult sizes and should be of good
quality
should be of good quality
contents should be provided in a good sized briefcase and
should include all the equipments of emergency
resuscitation including laryngoscopes with blades of all
szes,airways (all sizes),intubating styllette, ambubag with
mask
- Aqua, alcohol denat, sodium laureth sulfate, Sodium
Chloride, PEG-7, PEG-200, Glyceryl Hydrogenated , Palmitate
, Glyceryl Cocate, Dibutyl Adipate, Sorbic Acid, Citric Acid.
96
97
LEGGINGS FOR LEG COVER
SKIN CLOSURE SYSTEM
98
STERILISATION PACKAGING
MATERIAL
99
Nasophyrangal Airway
100
101
DISPOSABLE SHOE COVER
ADULT RESUSCITATION(CPR) KIT
102
Antimicrobial hand cleaning lotion
103
Intubating Stylette.
Should be malleable with plastic sheath.
Should have soft distal tip.
Should be sterile.
Should be available in sizes of 6fr---2.0mm,10fr--3.3mm & 14fr---4.6mm
104
Combitube
The tube should have unique double lumen
design for rapid establishment of an effective
airway through either esophageal or tracheal placement
There should be blind placement which eliminates the need of
laryngoscope..
The tube should have pharyngeal balloon which inflates to hold
device firmly in place and helps prevent the escape of gas through
nose or mouth.
The tube should have full length lumen which allows for suctioning of
gastric content s with no interruption of patient ventilation should the
tube airway be placed in the esophagus.
Esophagus cuff inflates to seal the esophagus so that gas does not
enter the stomach and gastric content are not aspirated .
Should be available in two sizes of 37fr 7 41fr.
Tube should have number of holes for better airway passage.
47
105
Closed suction system
106
Catheter mount
1. The catheter should be part of the breathingg system during
suctioning without disconnecting ventilator support.
2. The catheter should be atraumatic, dual density & should have
flexible, ultra soft , round distal tip .
3. The system should have rotating patient access valve to enable
complete isolation of the sleeved suction catheter from patient
airway when suctioning is not required.
4. The suction catheter should have all round depth marking in cms
that allow easy measurement of proper catheter insertion in the
trachea.
5. The catheter sleeves should have strength and transparency with
tactile sensitivity and a metered dose inhaler for more effective,
quick and convenient drug delivery.
6. The system should have an online closed port for bronchoscopy
up to 5mm bronchoscope.
7. Should have thumb Controller to control extra pressure from
suction machine.
8 Should have self sealing cap after bronchoscopy procedure is
performed.
Should be flexible, Should be having bronchoscopy port.
Should be of good quality.
48
Tender Group No. VI
Equipments for Medicine Department
S.No.
1
Name of Item
WASTE BINS
2
Alcolmeter (Breath Analyser)
With Printer
3
Drug Dispensing System
4
5
Metallic ECG Trolley with
Lockable Wheels.
ICU Bed Mechanical
6
Ultra violet Room Sterilizer
7
Vital Sign Monitor
8
9
Patient Mobiliser
Decontamination Cart
Specifications
It should be automatically open when hands will be near it
It will automatically close after 6 seconds
It should work on 6V Batteries only
The outer body should be made of Stainless Steel & inner should be
high quality ABS
It should have capacity of 30 Ltrs.
Also quote the price for Additional Inner Bin Separately.
The equipment should be a portable one ,light weight and can be
operated on battery as well as mains
The equipment should be able to measure quantitatively the
alcohol level in the expired air of an individual suspected to have
consumed alcohol.
The equipment should be able to give a printable record of the
measured alcohol level with date & time.
Should have Measuring range : 0.02 to 2 mg/liter BrAc
The equipment’s Response Time – 30 to 35 second at room temp.
Specificity – not to be affected by : a)acetone, b) Paint, c) Fumes
from glue, food, confections or any other item found in human
breath.
The equipment should have LCD Display.
The detection of alcohol should only be done with a Platinum
electrochemical fuel cell at temp -5 to 40 deg C.
Calibration- Automated either by dry gas or wet bath simulator.
Memory function facility (with date & Time), even after switching
off the instrument.
Downloading Facility.
Should be with all standard Accessories.
Should have able to store atleast 400 ltrs of medicines
Should have able in built revolving space saving drawers to keep
variety of medicines
Should have able lockable covers to prevent unauthorized access.
Should be mechanically operated backrest, height and knee break.
Should have parallel beam mattress platform.
Should have removable head and foot boards.
Should have tuck away side railings
Able to came cardiac chair position.
Should have integral telescopic IV Drip rod and urine bag hooks
CE mark
Should have able multilevel mechanical filtration, UV light,
electrostatic
precipitator (ESP), negative ion generator, Ozonation system and
Hepa filter.
Should have Bi directional connectivity to central monitoring system
Non volatile Trend graph memory
Design enables head rail mounting
Should have 7 ECG leads
Should have wave from freeze time selectable 30 Sec, 1 Min. 2 min 4
min
Should have buzzer system
Should have pacemaker detection & ST Analysis
Should be upgradable up to 7 parameters.
Should have roller based & easy to handle.
Should have U.L.V fogger
Should Have 3 tube U.V system
Should have Air purification/ Humidifier / De humidifier system.
Should be self powered too.
49
10
Patient record reterival
system
11
Three channel ECG machine
12
ECG machine 12 channel
13
Ophthalmoscope
14
15
Oto Scope
Spirometer
Should be open to all & password operated specific storage in one
with software as standard & compatible with all available formats.
Hand band type. Band should be reusable.
Shoulh not exceeded 2” x 3” inch to facilitate tying & carrage.
It should have Automatic, Mannual and programmed recording modes
12 Lead simultaneous acquisition
It has 3 channel and rytham lead recording facility, it has inbuilt high
resolution thermal recorder
It has alarm for different frault conditions, common error indicator ,
printer recorder error , beep sound of all keys.
It has indications of ECG lead selected, cursor position, filter on/off,
pacer detection and print error.
Should have 12 channel simultaneous acquisition, LCD display having
320 x 240 dots, displaying both 3 and 6 channel with interpretation
facility, inbuilt Thermal printer, capable of printing 3, 6 and 12 Channel
simultaneously, internal rechargeable Ni-Cd batteries, 12 standard
Leads, sensitivity of 5 mm/mV, 10 mm/mV, 20 mm/mV, 5 mm/s, 12.5
mm/s, 25 mm/s, 50 mm/s. Should have filters: Muscles tremors;
Power line interferences. Should support more than 2 hours of
continuous operation. Should conform to quality standards.
1. 2.5V/3.5V with aspherical optical system, having 74 single
diopter steps having xenon Halogen Bulb,
2. Recessed coating window,
3. Dust proof,
4. Having 7 apertures with separate free filter,
5. Suitable for large or small pupils,
6. Incorporated slit apertures,
7. Fixation star, cobalt blue filter and red free filter for improvrd
contrast.
8. Power source Rechargeable Battery/ Dry cell one.
9. Rates of Re chargeable battery should be quoted.
\
flow range -15- 16 liters/ min, volume range 0-8 liters/
Back light LCD screen
16
17
PFT Machine with paper
Echo Cardiography with
Colour Doppler machine
3.1 Latest generation Electronic Phased array Color Doppler system
with Minimum 512
Electronic independent channels.
3.2 256 gray shades for sharp contrast resolutions
3.3 Adult & Paediatric Trans thoracic Cardiac and Vascular Probes
to be supplied which should be latest generation wide band
transducers.
3.4 Harmonic Imaging- System should have following modes in
50
harmonic with separate
setting for:
a. Tissue Harmonic.
b. Contrast Harmonic
c. Harmonic Angio.
d. Quantification of harmonics imaging
3.5 Harmonic imaging capability in Adult Cardiac, Pediatric Cardiac
and linear Probe
3.6 Gain control in two dimensions for additional level of flexibility to
image quality control.
3.7 Real time high frequency 2D for higher resolution and low
frequency Doppler for higher
sensitivity in all probes
3.8 Frame rate should be 300 FPS or more
3.9 Steerable PW/CW in all Phased Array probes.
3.10 High-definition acoustic zoom for enlarging sections of 2D and
Color flow images with
more acoustic information for greater clarity and detail while
maintaining an optimal
frame rate.
3.11 Modes – 3D, 2D, M-Mode, Steerable PW/CW Doppler, Color
Doppler, and High Definition
Color flow.
3.12 Monitor should be 15" or more, high-resolution color Monitor.
Tilt and Swivel monitor should be able to view in all angles and all light
conditions.
3.13 Color Flow Imaging for
a) Increased lateral & spatial resolution.
b) Detection of even subtle areas of turbulence, displaying a more
physiological blood
flow appearance without loss of frame rate.
c) Color flow with capability of automatically picking up color flow as a
function of
focal depth
3.14 Tissue Colorization (B-Color) for improved contrast resolution
3.15 Application software for Adult, Pediatric, Fetal and Peripheral
Vascular and Trans
esophageal applications. (All application package should be built into
the system)
3.16 Cine loop memory- more than 120MB of memory.
a. High Frame rate review for better clarity of playback images study
in slow motion.
b. Quad loop with memory for pre and post image comparison of any
procedure.
c. Memory- 256 frames or more in quad loop. M Mode & Doppler
Scroll Memory-40
seconds or more.
d. Frame grabber facility for post analysis.
3.17 Various maps for pre and post processing.
3.18 ECG and respiration trigger facility.
3.19 User defined system and application presets for multi-user
department.
3.20 Minimum 4.8 GB optical disc drive for image storage and
retrieval. (Standard with
system)
3.21 Dedicated integrated dynamic stress echo package for flexible
user defined protocols
with stacked sub loops facility and contrast stress protocol usable for
stress
echocardiography.
3.22 Tissue movement colorization with quantification possibility for
IHD/CAD/Heart Failure
patients.
51
18
19
20
Finger Pulse Oxymeter
Sengstaken-Blakemore tube
ECG Paper roll
21
22
23
ECG Paper Roll
Surgical Tape
Bone Marrow Biopsy Needle
24
Liver Biopsy Needle
25
26
27
Kidney Biopsy Needle
Automatic Gum for biopsy
Spinal Needle
28
29
Pleural biopsy needle
AED
30
Trachostcomy tube
31
32
33
CVP Scale
CVP Connector lines
CVP catheter
34
Insulin Applicator
3.23 Three or more transducer ports.
3.24 Color Map resolution up to 128 levels.
3.25 Facility for high definition digital acquisition, review and editing of
complete patient
studies.
3.26 Facility of Real time perfusion studies
3.27 PC based Peripheral system comprising of dedicated computer
at least 100 GB storage
space (Hard disc) with 1 GB RAM or more with a Microprocessor
speed of more than
3.00 GHz, frame grabber incorporated (All Software Inclusive)
interfaced with the
echocardiography machine with DVD writer and a high quality Color
Laser printer.
CD/DVD produced should be playable on any system.
3.28 Color M-Mode
4.
C.E. certified ,measuring pulse and oxygen saturation Good quality
Z Fold
Orian Model (L & T)
For Vega Model Machine
Good Quality
1)Stainless steel with stellate and needle iliac crest Jamshidi
2) Stainless steel biopsy needle with guard and stellate sternal
SALAH
1)Menghini Type
2)Liver Biopsy Gun
3) TRUCUT BIOBSY NEEDLE
4) Wilms Silverman needle
Good quality Menghini Type
Renal biopsy automatic Gun disposable
1) Stainless steel Sizes from 18-28 Gz disposable 3-4 inches
Abrams pleural biopsy needle
System should work on biphasic rectilinear wave form.
System should have icon for complete chain of survival
System should provide CPR help
System should have pictorial and verbal help
System should run on easily available consumer batteries.
Disposable all sizes , cuffed , non cuffed
Tracheostomy tube PVC with low pressure high volume cuff,
adjustable flange 15 mm Connectors size5 ,6,7,7.5,8 &8.5
Good quality
CVP Cathetor(Triple Lumen ) (Seldinger type) full set 7.5 Frwith
dilator, needle (introducer) Guide wire ,2 syrings
Ultrasonic Insulin applicator is a microprocessor
controlled
transdermal drug delivery devices using the ultrasonic technology
which transdermal permeation of the insulin and other medium &
Small molecular medication.
It should the provide the diabetic Patients who administer insulin by
mean of inj., sustained release of the insulin & eliminates the pain
associated the drug Inj.
Transdermal drug delivery eliminates the irritation to the digestive
system via the oral & Gastrointestinal absorption.
52



35
Non-Invasive Bilirubin
Analyzer
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
13.
14.
15.
No Needles Required A Totally invasive insulin delivery
system
Direct Blood Stream absorption via on demand delivery
system
A Recharge able battery system is located with in device
Should have POCT instrument for non-invasive measurement
of total serum billirubin levels for neonates.
Should have no pain, no trauma, no risk of infection and no
hazardous waste
Should be able to perform during and after phototherapy.
Should be able to perform during age (24-42 weeks) and
post-natal age (0-20 days).
Measuring range should be between 0-20 mg/dl.
Should have accuracy of + mg/dl & standard deviation
(instrument to instrument repeatability) should not be more
than + 0.66 mg/dl.
Weight of instrument with battery pack should not be more
than 356 gm.
Instrument should have rechargeable battery of life minimum
1 year and measurement per full charge must not less than
100 test.
Should have tungsten bulb as a light source for minimum life
of 30,000 measurement.
Should have FDA approval, CE marked certificate and
published independent clinical studies.
Accurate results in standard clinical units regardless of race or
gestational age.
No need to perform separate analysis or refer to conversion
tables.
Immediate, point-of-care result gives you the information your
need, when your need it.
Clinical care decisions for discharge or therapy are made
more efficiently.
Consumables of Non-Invasive Bilirubin Analyzer
1.
36
Fully Automated
Biochemistry Alayzer for
Critical Care
Automatic calibration for each measurement with the
consumables ensures accuracy without a baseline
measurement.
2.
Cost-effective, standard of care, and convenient management
of newborn jaundice.
The instrument should be dry chemistry system to perform
chemistries, electrolytes and Blood gas tests.
Should be light weight/portable and should also run with automobile
battery.
Should have a memory to store more than 1000 patients reports
Test reporting time should be less than 15 minutes for any of the
profiles/group of tests
Should be use friendly and easy to operate even by nursing staff,
paramedics etc.
Should be able to test with very small amount of whole
blood/Serum/Plasma.
Should be CE Certified/FDA approved
53
Tender Group No. VII
PEADIATRIC DEPTT
(CONSUMABLES)
S.No
NAME OF THE ITEM
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
Hypodermic needles
Syringes
I.V. cannula
I V. set
Peadiatric drip set
Blood infusion set
Infant feeding tube
Ryle’s tube
Urinary catheter
Urine bags
Gloves
Umbilical catheter
Three way stop cock
Infant Urine Collector
Sterile Disposable Baby
Nappy
Oxygen mask
Oxygen tubing
IV Cannula Dressing
Mucous extractor
Umbilical clamps
Baby identification tags
Kidney biopsy needle
Uristicks
Central line
Disposable plastic apron
Disposable cap
Disposable mask
Disposable shoe cover
Chlorhexidine hand wash
bottles
Alcohol swabs
TECHNICAL SPECIFICATIONS
It should cone in size 26-20.
It should be disposable 1ml, 2ml, 5ml, 10ml, 20ml, 50 ml
It should made of silicone and Size – 26-18
Good quality polythelene tubing with a stopper
It should made of polythelene 100ml +- 10% chamber
It should made of silicone and size should be 5-10
Different sizes
Different sizes
Small, medium size
It should be sterile latex surgical gloves diff sizes
Different sizes
It should made of silicone with neo, pead size
It should be sterile and disposable
It should be single,sterile,transparent,water & bacteria proof.Size 5x5.7cm,
6x7cm.
Good quality
Non-breakable, good quality
Different sizes
Uristicks for glucose and albumin
Different sizes
Good quality
Male/female
3 layers with nose clip
Good quality
200ml, 500ml, 1000ml
Packed individually,
Should be wet
Spacer with mask
Different sizes
Complete tray for
It should have catheter, 3 way stop cock, 50ml syringe, 20 ml syringe, gloves
exchange blood transfer
and sterile sheet.
CPAP tubing
For bubbling CPAP
Liver Biopsy needle
Different sizes
Wooden Spatula
Pack of 500, 1000
Endotracheal tubes(cuffed) Cuffed endotracheal tubes, clear thermo sensitive material, radio opaque
line, 15mm connector. Good quality and atraumatic hooded tip, allows
easier insertion with cuff, in sizes 4.5, 5, 5.5, 6.
Endotracheal tubes (plain)
Plain endotracheal tubes, clear thermo sensitive material, radio opaque line,
15mm connector. Good quality and atraumatic hooded tip, allows easier
insertion without cuff, in sizes 2.0,2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6.
Bed Bath with Wet Towels
Should made of Non woven spunlace fabric
size should be 24 X 30 CMs approx
Laminate structure- 12 micron poly + 40 micron LDPE
with Aqua
Baby Bed sheet with It should be made of non woven spunlace fabric of 40 gsm laminated with
cushion
12 micron LDPE.
54
NON – CONSUMABLES
CONSUMABLE OF EQUIPMENT, IF ANY MAY BE QUOTED SEPARATELY
1
Laryngoscope fibre optic
(for Infants)
Set containing1. Laryngoscope Blade laryngoscope blade with specially designed viewtube allowing
vision of 46 degree from straight line of sight,
 integral oxygen supply tube allows extension of intubation time,
 easy link up to Endoscopic systems provided
 Stainless steel , fibre-optic blades that complies with Green
System (ISO 7376(iii) compatible) handles
 blade that fits on to International standard ISO compatible
handle,
 all contact points between blade and handle must be of stainless
steel.
 Production batch number must appear on blade
a. Optishape Stylets
 Re-usable stainless steel stylets, two sizes with patented ideal
shape.
b. Handle
 Rechargeable Handle
 Xenon bulb with light output in excess of 2,800 Lux.
 Must hear click when blade is engaged onto handle to protect
against faulty placing of blade
 Handle components of electrical system must be manufactured
from stainless steel to prevent corrosion
 Handle conform to international standard ISO 7376(iii)
2
3
Oxygen Hoods
Ambu bags
4
Weighing machine
5
6
Weight and height
measuring scale
Vital Sign Monitor
7
8
Kidney Tray
Nebuliser
9
10
Bed pans
Digital thermometers
11
Suction machine electronic
It should be made of polycarbonate with small, medium and large size
Self-inflating silicon resuscitation bags with volume of 250-500ml..
Should have facilities to connect oxygen reservoir bag. Should have springloaded pop-off valve set to 35-40 cm water pressure
Should be provided with non-rigid silicon facemasks of sizes – 0 and 1.
Electronic baby weighing scale with flat baby tray which can be used for lying
down and sitting babies with detachable baby pan.
Unit should have 0-20 kg range and 5 gm resolution/accuracy through the
range.
It should work on AC as well as rechargeable battery.
I t should be electronic with digital display and weight upto 180 kg or more
and height upto 185 cm unit should be CE certified with BMI
Vital sign monitor minimum 5 parameters: spO2, NIBP, temp., ECG, RR with
facility for up gradation for invasive monitoring for CVP & intra arterial
pressure with colored screen display size minimum 8" screen with battery
backup of 90min., should be complete with all accessories. CE/FDA/TUV
certified/approved.
It should be made of SS and size small, medium large.
Nebuliser Piston Compressor Heavy Duty with mouth piece, Adult
mask,connector,5-filter
It should be made of S.S with standard size
It is having both Celsius and Fahrenheit scales Auto switch off facility •
Washable
Suitable for oral as well as axillary measurement
Electrically Operated ISI marked, heavy duty motorized pump/1HP & ½ HP, 2
suction jars of 2 ltr. capacity each, suction capacity 25-35 ltr. Per minute,
55
12
Suction Machine foot
operated
13
Billrubinometer
14
Glucometer
15
16
17
Infantometer
Flux meter
Non – Invasive Blood
pressure Monitor
18
Breast feeding Pump
19
ABG machine
pressure upto-700mm of mercury, cabinet with SS top and handle, 8-10mm
dia non collapsible tubing, moveable on castors, overall size 40X30X65 cm.
It should be small size, battery operated.
It should be have max. negative pressure value 0.08 pa. Reservoir capacity
should be 1000 ml and should be certified.
Unit should have Liquid Crystal Display for easily view.
Should be Streamlined designed and easy to be handled., low energy
consumption.
It should have Battery indicator.
It should provide test results rapid providing serum bilirubin concentration.
It should have Storage and memory function.
It should be 7. Convenient to browse and delete functions. And should be
certified.
It is capable To Measure Glucose From
small drop of blood obtained by pricking the
skin.
It has disposable test strip, which the meter reads and uses to calculate the
blood glucose level.
Test strip have a shelf life of 2year
The meter displays the level in mg/dl and mmo1/l
_._It should be made of polycarbonate and should be standard size
Unit should be able to measure the intensity or the lux of fluroscene tube.
Displays plethsmogram wave form, trend, battery status, time and Date.
Read through motion and low perfusion conditions.
It should have Audible and visual alarm for pulse rate B.P., system failure and
low battery.Pulse rate from 25-250 bpm.
With accuracy +-2 NIBP measure mode auto surge
Working mode auto/ manual,
For adult, Paed, Neonates.
Alarm range for systolic, diastolic and mean pressure.
Power 220V, 50 Hzs.
Screen size 5.8”
Wt. 1.5 Kg,
Unit should have a cup to fit the breast to extract the milk in a bottle directly.
The mouth of bottle should be computable with the nipple attachment so that
the baby can be fed without touching and transferring the milk. It should work
both on battery and AC
Fully automatic, upgradeable fast and latest blood gas and electrolyte combi
analyzer.
Simultaneously measured following parameters: pH,pCO2., pO2, SaO2,
tHb,Na+, K+, Ca++, Cl-, and Hematocrit in one single machine with one single
aspiration of blood sample.
Calculated parameters which includes BE, BEecf, BB, HCO3-, tCO2, stHCO3-,
stpH, ctO2, aH+, AaDO2,MCHC,Anion Gap with COHb & MetHb flagging .
Sample volumes – 75 micro lit max
Sample throughput – 30 samples / hour
Fast analysis time - maximum 50 sec to results.
Maintenance free electrodes with individual electrodes ON / OFF facility
Fully automatic liquid calibration of all parameters at user-defined intervals
without the use of Gas equilibrated reagents, external gases, tanks &
regulators.
Reagents should be in separate bottle which can be individually replaceable(
Not one pack system)
Continuous reagent level monitoring with graphic display.
Automatic sample device recognition.
Upgradeability for auto QC .
Data display on well illuminated 5” LCD color touch screen display.
Data printout on in built graphic printer.
Storage facility of measured data in case of power failure.
Built in data storage facility for at least 25,000 patient results
56
20
Pulse Oximeter
21
Infant Radient Warmer
Built in QC analysis software for Levy Jennings.
Built in barcode reader.
Built in optional Auto QC facility.
RS 232 interface facility.
Built in Network and remote control facility.
Built in voltage stabilizer for the range of 100 – 240 V / 50 Hz with 601-1
compliance
Should be latest model and FDA approved.
It should have at least 5” screen display Spo2%, pulse rate, Plethesmograph
waveform, bar graph, alarm for high low status.
Trend for 24 hrs.
It should have Adult and neonetel probe.
It should Microcomputer based temperature controller.
It should have both manual and servo modes of temperature control.
It should have Skin/ Air/ Manual mode.
It should have High temperature cut off system temperature alarm for both
skin and air (skin, +- 1 degree C alarm, Skin >38 degree alarm, air over
temperature alarm, sensor failure alarm, heater failure alarm)
It should have Halogen examination lamp
It should have Heater wattage of 600 watts In manual mode unit the user is
able to control
heater outputs as well as time duration limit for manual mode.
It should have APGAR timer, attend baby alarm,
It should have set temperature range skin 25 C- 39 degree C, Air 25 degree
C – 39 degree C, resolution 0.1 degree C
Unit should have easy access from all sides with thick Acrylic collapsible side
panels.
Unit should have Acrylic baby tray with infants head up/ down facility and
foam mattress.
S.S tray with slot to use under surface photo therapy
22
Infant Open care system
It should Microcomputer based temperature controller
It should have both manual and servo modes of temperature control
It should have Skin/ Air/ Manual mode
It should have High temperature cut off system temperature alarm for both skin and
C alarm, Skin >38 degree alarm, air over temperature alarm, sensor failure alarm, he
It should have Halogen examination lamp
It should have Heater wattage of 600 watts In manual mode unit the user is able to c
heater outputs as well as time duration limit for manual mode.
It should have APGAR timer, attend baby alarm, It should have set temperature rang
degree C, Air 25 degree C – 39 degree C, resolution 0.1 degree C
unit should have easy access from all sides with thick Acrylic collapsible side panels
Unit should have Acrylic baby tray with infants head up/ down facility and foam mattr
to use under surface photo therapy
Unit should have Vital sign monitor minimum 5 parameters: spO2, NIBP, temp., ECG
96 hrs trend with colored screen display size minimum 7.4" screen with battery backu
should be based on nellcor technology. review of ECG should be available . It should
Y sensor probe, temp probe ECG cable should be provided as standard accessories
to Central Nursing Station. wireless connectivity should be possible upto 16 beds.
Unit should have syringe mounted on side pole of the warmer it should have Volume
Automatic calculation of infusion amount having feature of keeping vein open by low
blood coagulation, it should have drug liberary also. Uses different brands of syringe
ml -50 ml Power supply 220-240 volts and battery backup facility Volume setting rang
depending on size of syringe.
23
Double Surface
phototherapy
Should have compact fluorescent lamps blue & white on both surfaces
(double surface )
It should have 4 blue and two daylight CFL lamps on upper surface and 2
57
24
Single Surface
Phototherapy unit
26
Neonatal Crib
27
X – Ray view Box
28
NEWBORN CPR MANIKIN
29
Hand sterilizers
30
Phototheray Eye band
blue and two daylight CFL lamps on lower surface.
Should provide irradiance of over to 10uw /cm2/ min in 420-480 nm range
Should be mounted on high quality castors with locking mechanism
Should have provision for easy adjustment of height and side positioning
It should have detachable cradle.
It should run on run on 200-250 volt
Phototherapy unit should have
Compact fluorescent lamps blue & white on both surfaces (double surface ).
It should have 4 blue and two daylight CFL lamps on upper surface and 2
blue and two daylight.
Should provide irradiance of over to 10uw /cm2/ min in 420-480 nm range
Should be mounted on high quality castors with locking mechanism
Should have provision for easy adjustment of height and side positioning
It should run on 200-250 volt
It should be preprex transparent crib with mattress.
Unit should betrendlenburg/ reverse trendlenburg 5 cms castors, I.V. rod.
Fluorescent View Box - Specially ultra thin panel X-Ray Film View Box Using
External Electrode Fluorescent Lamp Technology,
Suitable For Viewing Film Size Up To 14"X17",
Light Weight And Slim With Panel Thickness Not More Than 1.5 Inches,
To Provide A Uniform Light Pattern With An Output Ranging Between 7000
To 12,000 Lux.
The life span should be 20,000 Hrs or more.,
Easy insertion and removal of films with a automatic switch which turns on
with the insertion of the film and turns off when the film is taken out.
It should have adjustable brightness control and flicker free high frequency
light for reduction of eye strain.
It should be light weight ,rugged with no internal parts to break.
It should have life like anatomical landmaeks such as nipples,xiphoid process
and substernal notch
It should have realistic chest rise
Ozone discharge controlled ,
Fully automatic system with wall mounting having features of sterilization in
approx. 10 seconds.
Sensor technology and timer facility
Sterility level approx. 99.9%.
1. It provides the best eye protection from visible light,making it the
safest phototherapy mask available.
2. Special eye-pad material blocks more visible light to the baby’s eyes
than other normal masks.
3. A soft ,absorbent elastic band holds the eye-pad securely in placeso
the baby can’tpull it off.
4. Shape of symbolic animal of the birth year is specially
designed.Shape of Ox head for babies born in 2009.
31
32
Bone Marrow Set
(Aspiration/biosy)
Stethoscope(Pediatric)
Good quality CE/ISI mark
58
Tender Group No. VIII
GYNAE & OBST. DEPARTMENT
NON-CONSUMABLES
S. NO.
Name of Item
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
Specifications.
Outlet Forceps
Uterine clamp
Kockker’s clamp
Mayoma screw
Metallic bladder catheter
Uterine Manupulator
Endo uterine aspiration
currette
Cusco”s speculum
It should be S.S.
It should be S.S.
It should be S.S.( diff sizes)
It should be S.S.
It should be S.S.
It should be S.S.
It should be S.S.
Sim’s speculum
Post vaginal wall self
retaining speculam
Mosquito Artery forcep
S. shaped vaginal retractor
mellables
Russian tooth forscep
Uterine sound
Sponge holder
Alli’s forceps
Non- toothed forceps
Toothed forceps
Episiotomy Scissor
Suture cutting scissors
Mayo’s scissors
Needle Holder 6”,8”
Vulsellum
Basins different size
Ovum forceps
Cord clamps
D&C Set
Blunt and Sharp Curette
Artery Forceps straight
Artery Forceps curved
Anterior Vaginal wall
retractor
Kidney tray
Instrument tray with cover
Green Armytage
Cheatle Forceps
E.B. Currette
Cidex Tray
Doyen retractor
Robert artery
Right angle forcep
Zernis retractor
Longeh back retractor
Deaver's retractor
Towel clips
Dressing drums
Thermometer
CVP SET
Cannula and pyramidal
It should be S.S. small, medium, large size
Long blade
It should be S.S. small, medium, large size
It should be S.S.
It should be S.S. (different sizes)
It should be S.S. (different sizes)
It should be S.S.
It should be S.S.
It should be S.S. ((different sizes)
It should be S.S. (different sizes)
It should be S.S. (different sizes)
It should be S.S. 6”, 8” in size.
It should be S.S.
It should be S.S. 6”, 8”, 10
It should be S.S. 6”, 8”, 10
It should be S.S.
It should be S.S. 12”,15”,18”
It should be S.S.
It should be S.S.
It should be S.S.
It should be S.S.
It should be S.S. 6”, 8”
It should be S.S. 6”, 8”
It should be S.S.
It should be S.S.(diff sizes)
It should be S.S. (diff sizes)
It Should be SS, (different sizes)
It Should be SS, (different sizes)
It should be S.S. (different sizes)
It should be S.S. (different sizes)
It should be S.S. (different sizes)
It should be S.S. (different sizes)
It should be S.S. (different sizes)
It should be S.S. (different sizes)
It should be S.S.
It should be S.S.(diff sizes)
Fixed and flexi tip mercury free
it should be with double luman and with single luman.
10/11 mm cannula and pyramedal trocar with valve and
59
49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
trocar
Pyramidal Trocar with valve
and stopcock
L-Shaped hook
Spatula Electrode
Suction irrigation cannula
Bipolar cable
Bipolar forceps
Atraumatic grasper
Toothed grasper
Maxigrip
Maryland Dissector
Metzenbaum Scissor
Hook Scissor
Babcock Forceps 5mm
Rotatable and dismentable
with and without ratchet
handle insulated 32cm long
Clip Applicator
Needle holder with ratchet
64.
Reusable Hassan trocar
65.
Laparoscopic needle holder
66.
Self righting
Optical cleaning system
67.
stopcock for insufflator tubing
5/5.5mm cannula and pyramedal trocar with valve and
stopcock for insufflator
L- shaped hook electrode insulated 5mm
Spatula electrode insulated 5mm
Suction irrigation cannula with pistol handle system
Bipolar cable to be attached to bipolar forceps
Bipolar forceps 32cm long 5mm
Atraumatic grasper 5mm Rotatable and dismentable with and
without ratchet handle insulated 32cm long
Toothed grasper 5mm Rotatable and dismentable with and
without ratchet handle insulated 32cm long
Maxigrip 5mm Rotatable and dismentable with and without
ratchet handle insulated 32cm long
Maryland Dissector 5mm Rotatable and dismentable with and
without ratchet handle insulated 32cm long
Metzenbaum Scissor 5mm Rotatable and dismentable with and
without ratchet handle insulated 32cm long
It should be 5mm Rotatable and dismentable with and without
ratchet handle insulated 32cm long
It should be 5mm Rotatable and dismentable with and without
ratchet handle insulated 32cm long
It should have medium large clips
Needle holder with ratchet
Reusable Hassan trocar for laparoscopy Reusable ,1012mm,blunt tip
Laparoscopic needle holder 5 mm self- righting for allowing
automatic upright positioning of Needle at different angles to
the instrument shaft.Approx length 310mm
Self righting Laproscopic needle holder 5mm -310mm
It should provide cleaning of lens without removing telescopes
System to have tubing, irrigation syringe, suction tube etc. for
10mm telescopes for approx. 300mm length
69.
Disposable laproscopic
scissors
Monopolar cable
70.
FIBRE OPTIC CABLE
FIBRE OPTIC CABLE 4.8, 230 cm long to be attached to
telescope with light source
Maryland Grasper forscep
Uterine Manupulator forcep
Tripolar cautery forcep
Fan retractor
Dissector
Delivery Bed
It should be standard sizes
It should be standard sizes
It should be standard sizes
It should be standard sizes
5mm, 10 mm
Three Sectional Stainless Steel top.
Epoxy Powder coated frame & assembly.
Large Perineal Cut.
Hydraulic height adjustment from 550mm to 920mm with
pedals on both sides.
Pneumatic stepless adjustment for back section 700 for
Tredelenburg and reverse tredelenburg (140 & 30 respectively).
Sliding Stainless Steel basin.
Additional support bar.
Folding foot section (Telescopic Type). Antistatic mattress of
80mm thick.
150mm dia four castors with central Braking and steeling
facility.
Accessory rails on both sides for fixing accessories.
68.
71.
72.
73.
74.
75.
76.
Disposable laproscopic scissors
Monopolar cable for laproscopic instruments
60
77.
Fetal, maternal monitor
78.
Multi functional obstetric
table
79.
B.P.Instrument mercury
free LCD display
80.
Medical Video Recording
system
81.
Gynae Examination Light
Mobile O.T. Light
82.
Pulse Oximeter
83.
Multipara meter
Complete with standard accessories I.V. Rod, Lithotomy leg
supports.
12.1” high-resolution TFT LCD display, support plug-in large
screen display.
Standard configration FHR, TOCO, FETAL MOVEMENTS,
ECG, SPO2,NIBP,RESP, TEMP, PULSE RATE.
Optional twins
Built in battery, portable and light wt.
Dynamic save and display the monitored information within 48
hrs.
Facility to connect with the central monitor. And thermal printer.
Multi function table designed for delivery, abortion and
gynecological examination.
Should be easily operational and with reliable safety.
The bed surface should have a back section , a seat section
and a leg section.
The up and down movement of the back section and the
forward and backward tilt of the bed surface should be
contrlooed by the wheels.
It should have a hydraulic up and down monements.
Ht. Adjustments 650x895mm.
Max degree of backrest adjustment up 75 degree and low 6
degree.
Automatic BP instrument with LCD bar display MERCURY
FREE Having following features LCD
Digital display system along with vertical LCD bar display for
both systolic and Diastolic Measuring method - Oscillometric.
BP range - 0-300mmHg with accuracy + 3 mmHg
Pulse range = 30-180 per minute,
Power source battery.
Fixed on wall or on plastic stand having facility to keep cuff.
Optional: Stand with wheels for the above.
It should have High resolution screen with 170 degree angle of
vision, pause and record facility.
It should have built in hard drive at least 160 GB. A/V in and
A/V out mode, IR remote controlled. I
It should have rechargeable battery, input connection
composite Video and S video.
Unit should have Adjustable height trolley,
wheel mounted with articulated arm.
LED technology having life of approx. 50000 hours.
Power supply 100-240 volts, Power consumption approx. 25
watts.
Colour temp. - 5000 K
Light adjustable from 25000-50000 Lux
Temp increse - Minimum
Colour rendering index CRI - 86
Trolley mounted light with lockable wheels and articulated arm.
1. Digital and microprocessor controlled LED Lamps
2. Light Intensity- 100000 Lux, and adjustment by feature touch
panel
3. Colour temp - 5000K
4. Colour rendering index CRI - 86
5. Temp Increase on operating field/Operator head - zero deg.
6. LED lamp life approx. 50000 hours
7. Power supply 220-230 volts, consumption approx. 80 watts
It should display Spo2%, pulse rate, Plethysmograph
waveform, bar graph, alarm for high low status.
Trend for 24 hrs.
It should have Adult and neonetal probe.
It should have 10.2 and15” TFT display with ECG waveform. It
61
91
84.
Infusion pump
85.
Syringe pump
86.
Fetal Doppler
87.
Suction machine
88.
SCALPLE & SHARPS
TRANSFER INSTRUMENT
89.
90.
Vantouse cups
Video Colposcope
Telescope
92
Electronic Co2 Insufflator
has arrythemia analysis, ST segment detection
Parameters – ECG,SPO2,RESP,TEMP,NIBP
Probe – neo/pead/adult
Infusion pump having following features:Flow setting 1-1000 ml per hour Dose calculation feature
Alarms for error with LED light & buzzer
Having battery backup and status of battery charge Keep vein
open feature at low speed
Peristatic pump method Purge facility i.e rapid flow volume
Alarm for bubble,
Tube clog,
Door open,
Flow error ,
Low voltage Power supply 220-240 volts
Volume range 0.1-999.9 ml,
Automatic calculation of infusion amount having feature of
keeping vein open by low speed to prevent blood coagulation
Uses different brands of syringes and different size 10 ml -50
ml Power supply 220-240 volts and battery backup facility
Volume setting range 0-1200 ml per hour depending on size of
syringe
Doppler should battery as well as mains operated;
rechargeable batteries ;
Digital rate display and with auto correction processing;
Built in loud speaker and active noise reduction
Light weight and compact unit, portable (hand held)
Suction machine ½ HP and 1 HP, 2 lit twin jars noiseless, air
control knob, mounted on sturdy base with wheels, ISI marked
An instrument to safely transfer scalpels at the time of use or
after use , so that whatever way the scalpel is dropped it is
parked in the tray in the fashion to avoid injury to the user. It
should be GAMMA Sterilized & made of biodegradable
material. It should have provision to be used for transfer of
other instruments also.
Silicon cup diff sizes with hand suction
Unit should have high resolution images,
Camera with at least 800 pixels, ultra high frequency intensity
cold light source in loop shape, even, bright, and shadowless.
Video output AV/S-V connectable with TV and monitor.
Images can be displayed, captured and stored and printed in
real time, step free continuous zoom and focus electronic filter,
capable of databasing for managing patient demographics,
administrate with doctor’s ID compose, print clinical report with
integrated patient images and relevant annotations.
Unit should have digital camera, software, video cards color
printer and trolley.
It should be CE certified.
Telescope should be 0 degree 10mm and 30 degree 10 mm
enlarged view, rod lens 10mm diameter should be approx 32
cm length . unit should be autoclavable.
Electronic CO2 insufflator it should be with pin index
connectors, silicone tubing set high Pressure hose, CO 2 bottle
empty, with pin index connection, universal wrench, CO 2 gas
filter, sterile disposable package of 10, insufflation’s pressure:
30mm hg(max),gas flow 20 Lt./min. Display: digital display of
patient pressure and gas flow, clear adjacent bar diagram for
set value and actual values , monitoring of insufflations
procedure. Optical and acoustical warning signal in case of
patient over pressured electronically controlled gas refill, all
secondary functions for bottle pressure, gas pre heating,
62
insuflation mode should be clearly displayed on large TFT
screen. The unit should be fully driven by touch screen.
93
Display Monitor
94
Xenon Light Source
95
Obstetric Labour Table
96
Ambulance Stretcher
97
Scoop Stretcher
98
Head Immobilizer
99
Stretcher on Trolley with
matterss
101
Folding stretcher
102
Foot Step Double
103
Lab Technician Stool
104
Over Bed table
105
Soiled Linen trolley with
plastic Bucket
106
Soiled Linen trolley with
canvas bag
LCD COLOR Monitor, screen 19” with RGB System medical
grade
It should be Cold light fountain Xenon 300 lamp type: Xenon
lamp,300 watt color temp.Ca 6000k, light outlets: 1
continuously adjustable light intensity from 0 to100% by the
camera video output signal. Fiber optic light cable size
4.8mm,length 250cm. It should be Capable of transmission of
adequate illumination . unit should be driven with a touch
screen multi language menu, all information for lamp life time
and temp- and light intensity etc. should be displayed on large
TFT screen. It should be CE/ISO certified. It should have flash
memory of last retaining used . adjust,ment of light intensity 5%
to 100% motorized.
It should be telescopic with adjustable height
approx dimensions is 72” L x 27”w x 24-32” height, tubular
frame work,mounted on swiveling castors., it should have S.S.
top in three sections with trendlenburg position, adjustable by
pneumatic gas spring system, hydraulically height adjustable
by foot paddle from side,l backrest section adjustable on
ratchet, leg and section can slide under the main section,
height adjustable a pair of knee crutches. It should be Pre
treated and epoxy powder coated.
Should Be CE marked
It should be lightweight, strond structure, easy antisepsis, can
be automatically folded through the hand control handle. It
should made of high quality alloy tubes. Load weight should be
upto 120 kg, diameter of the castors should be at least 125
mm.
It should be portable, first aid stretcher. It should have a clutch
zip design at the middle of the unit and can be divided in to two
parts. The stretcher length can be fold or be separated. it
should have bearing pressure < 159 kg.
It should have multi axis block system to accommodate all
hesad shapes and injury positions. It should have direct access
to patient ear for better communication and inspection. The
blocks should have disposable foam pads straps so as to avoid
inconvients of taping.
It should have tubular frame work of M.S. pipe, swing away
type side railing of S.S>, adjustable I.V. rod, utility tray, cylinder
crtridge, castors of 6” diameter with brakes. Epoxy powder
coated finish.
It should have aluminium poles but folding lengthwise as well
as widthwise.
M.S. tubular frame fitted with PVC stump. CRC sheet duly
double press bent, it should be epoxy powder coated.
It should be height adjustable cushioned seat and 5 legs base
on castors.
It should be adjustable by gear handle, it should be laminated
with membrane pressed top, pre treated and epoxy powder
coated.
It should have push handle at one end, frame work on CRC
tube mounted on 10 cms castors, superior quality plastic
bucket, pre treated and epoxy powder coated.
It should have frame work on CRC tube mounted on 10 cms
castors, superior quality canvas bag, pre treated and epoxy
63
powder coated.
M.S. tubular frame work mounted 5 cms castors
Unit should be approx size 91 L x 50 W cms, frame work of
CRC tube mounted on 10 cms castors, height adjust5able by
gear handle, epoxy powder coated.
Tray size should be 56 L x 40 W cms frame work of CRC tube
mounted on 5cms castors, height adjust5able by side knob ,
epoxy powder coated.
Emergency cart of high density resin / steel with plastic
framework, having, Defibrillator board, Oxygen cylinder holder,
Needle containers.
Facility for storing suction tubes, Endotracheal tubes etc.
Drawers of different configurations with locks.
107
108
Kick Bucket
Instrument Mayo Trolley
109
Mayo Trolley
110
Emergency Trolley
111
Cubical Track System
Should be Made of Metal Aluminum Alloy of Box size 1.7 x 20
x25 mm with 50-60 microns thick powder coating in white color
finish. Tracks should be bendable to a radius of 300 mm at 90
degree to cover the whole bed. Curtain should be made of
Hospital grade premium quality Stain Proof fabric with high
quality Nylon Net of 18” and 24” on top. Supporting system
should consist of wall bracket Made of CRC steel with powder
coating finish, Bridge Clamp Made of Aluminum with white
powder coating finish, Roof Suspension Made of aluminum
pipe of 12.5 mm & 19.5 mm diameter. The upper circle should
be made with aluminum with 50.4 mm diameter thickness.
Should be with white powder coating (Outer Surface) finish &
are of variable height fixed with the ceiling with anchors, bolts,
screws etc. Curtain removable point should be made of SS for
simple loading and unloading of curtains. (Also serve as an end
hook retainer). Runner should comprise of Wheel type runners
are made of Teflon for easy and smooth sliding of the curtain.
The price should be quoted for per running feet & should be
including installation
112
IV bag holder
Should be a 5 bag holder fitted onto the ceiling which should
raise and lower without disturbing needles and tubes or
causing patient discomfort. Should be made from SS for
sanitation. Arms should fold for sterilization & easy storage.
Should have a open length of 41.5” & a closed length of 27”.
Should have easy one arm operation. Should run on tracks.
Installation to be done by the supplier himself. The price should
be quoted for per running feet.
113
Cleansing system
Should have high velocity & powered jets nozzles of clean
filtered air on both the ceiling & walls. The jet air flow of
30.5m/sec should be provided by the adjustable nozzles.
Should be plug & play modular unit. Should scrub off
particulate matter on the clothing.
Should have a 3 pre-programmes offering user selectable full
auto, semi-auto, manual modes. Should be based on electric
logic circuit to control various operations. Should also have two
operation modes of entry only entry & exit also user selectable.
Should be provided with a non contact detection system to
enable auto operation, of door open/close detection, with
magnetic sensors. Should have the option of auto start with
infra red detection system to bring in automatic functioning.
Should be provided with electric trouble free magnetic door
locks. Should be constructed from CR M.S. Epoxy Powder
Coated, with Aluminium Framed Glass Door. The outer
dimension should be 1725X1000X2400mm & the loading inner
dimensions should be 900X900X1950mm. the floor should be
64
grated to act as a dust trap.
Should have a 3 filtering process with 10 micron fresh air filter
to keep inside air fresh, 10 microns washable pre filter & 0.3
microns dop tested 99.97% efficient HEPA filter.
The backbone of the system blower should be of hi-efficiency
to make the system effective.
Should have a both inside & outside for quick servicing
The manufacturer should be ISO & WHO-GMP certified. The
product should be CE Marked.
114
115
MEDICAL RECORD
TROLLEY
CASE SHEET HOLDER
116
117
Monitor Trolley
OT pendent
118
Autoclave (Vertical)
119
Autoclave portable
120
laprocator
121
Electro surgical unit
ABS framework, table top, Sliding board beneath table top,
Approx 30-50 no of layers for file holder with lock.
ABS material case sheet holder for patients records. Approx.
150 mm x 250 mm x 30 mm
Unit should have approx size 800 mm w x 1408 mm H
It should be single arm surgical pendent, rotation within 340
degree and fixed flexibility according to the requirement . it
should have pneumatic brakes, medium load capacity, easy
manual arm movement.
Unit should be vertical high pressure steam sterilizer under
pressure of 15 to 20 PSI. triple chamber with inner chamber
and steam jacket made of SS sheet reinforced with M.S. sheet,
double safety valve, water level indicator, water inlet and drain
valves. It should work on 220 volts, total load 4 KW
It should be single/double drum made of aluminium alloy with
turning on lid highly polished . sixze should be 14” x 16”
Single puncture laproscope with side view both 90 degree and
45 degree with a length of 268 mm, and working channel of
6mm.
Verus insufflation needle 2.0mm, length 100,120 mm
Ring applicator 6mm, 287mm
Unit should be Microcontroller based isolated electrosurgical
generator having both monopolar and Bipolar outputs designed
for all surgical procedures. Smart generator should be able to
monitor changes in tissue impedence continuously and adjusts
power.Monopolar outputs should have three cutting modes :
 Low cut forr delicate tissue of laproscopic cases having
maximum power of 300 W at 300 ohms.
 Pure cut for clean , precise cut in general surgery
having maximum power 300 W
At 300 ohms.
 Blend mode for cutting with homeostatis having
maximum power of 200 W at 300
All cut modes should be able to adjust output power depending
on tissue density by less than 15% or 5 W, whichever is
greater.It should have three coagulation modes with maximum
power of 120 W at 500 ohms, dessicate mode for low voltage
contact coagulation suitable for laproscopic and delicate tissue
work.
Fulgurate mode for efficient non contact coagulation in most
applications.
Spray moede has randomized spray effect of verifying
amplitude and frequency for large tissue areas with minimum
depth of necrosis.
It should have three bipolar modes with maximum power of 70
W at 100 ohms.
Precise mode to have fine control of desiccation in delicate
tissue.
Standard mode for application at low voltage to prevent
sparking.
Macro mode for application on tissue with high resistance
It should have patient plate monitoring facility and should give
65
audiovisual alarm
and deactivate output if contact
between patient and patient plate is not proper to eliminate the
risk of patient burns.
It has two hand switchiong and two foot switching monopolar
outputs and one hand switching and one foot switching bipolar
output.
It has membrane keybord for power setting.
It has individual digital display of power for bipolar , monopolar
cut monopolar coagulation.
It has temperature sensing cooling fan.
It has RS 232 serial port to interface with computer to reduce
the time ion problem diagnosis.
It should be compatable with Argon Beam Coagulator and
Ultrasonic aspirator system.
It has RF activation port to tell other equipments like ECG or
EEG that RF current is being generated.
It has RF leakage current less than 150 mA.
It should have a minimum of Capacity – 100 L
Inner body size(mm) should be minimum : 310*470*800
Should have Quantity of racks – min. 3 Nos.
Power supply - 220V
Should have Disinfecting time of 3-6hrs.
Should have the capacity to hold Various models of
endoscopes-including rigidity and tender type: arthroscope,
cystoscope, bronchoscope, colon-scope, gastro-scope,
duodenumoscope, laryngoscope, and rena-scope and some
endoscopes which are not very long. Conventional heatsensitive equipment and bone electric drill, etc. Various
plastic products: line box, pipeline, and heat-dissipating
cable, etc. All mental, rubber and glass, etc
 Esp. some medical devices which are susceptible to high
temperature, humidity, and erosion.
 Should have the Efficiency of disinfection - 99.999%
 The chemical used to disinfect the instruments should be
gluteraldehyde






122
INSTRUMENT
DISINFECTING CABINET
123
Ethylene Oxide Sterilizer
The unit should be made out of stainless steel 304 chambers.
Stainless steel back plate as well as S.S./M.S. door. The unit
should have individual valves for exhaust, allowing gas in the
chamber and for vacuumising. The unit should have vacuum
pump, chamber heating and control system. Should be a table
top model suitable for 2 Nos. Sterilizing Baskets & should be
easily placeable on table size of 2.5’ X 4’. The unit should have
fascia panel with all accessories pump etc. are enclosed with
stainless steel cover. Gauges and controls should be provided
in the fascia panel. This model should be specially designed for
Hospitals & Lab.
The unit should be suitable for working with 10 : 90 EO : CO2
or 12: 88 EO: F-12 mixture.
Dimensions should be 250 (H) X 300 (W) x 550 (D) mm.
The manufacturer should be ISO & WHO-GMP certified. The
product should be CE Marked.
124
sliding door,
Rail construction should be aluminum profile, with hermetic
closing. Canopy
should be coated aluminum plate in
standard RAL9006 aluminum color. Should have stainless steel
lever handles on both sides. The door blade should be Anodized
aluminum surrounding, 4-sided, blind fixed with thickness of 60
mm flushed on both sides. Door core should be made of CFC-free
Polyurethane, thickness 48 mm. The top layer on both sides
should be hard HPL plastic laminate of size 6mm. should be
provided with gasket on all 4 sides of the door blade to ensure
66
hermetic sealing up to 150 pa over or under pressure. Should have
inbuilt window double glazed flushed glass quality should be both sides laminate
weight should be approx. 100 KG, & rail and canopy approx. 25
KG. Sliding direction should be DIN-Right or DIN-Left. Inside frame
dim should be 1500 x 2100 mm. high (example), Clear opening
should be 1380 x 2100 mm. high. The dimensions should be
adjustable as per the requirement of the specific door.
125
Ultrasonic Cleaner
It should be useful for cleaning of Instruments
It should have Latest International Sweep Technology
It should be compact one-piece construction;
Capacity should be minimum 20 Ltrs.
Maintenance should be easy; no moving partsshould be there.
It should have esthetic model with non rusting body
The tank should be made of 304 Stainless steel dye pressed
It should clean all surgical instruments including metallic or
plastic parts like suction tips, endotracheal tubes, sharp
instruments etc.
126
Bed weighing Scale
127
Dust barrier reusable Mat
(2x4ft)
128
Air Purification System
129
RIPPLE BEDS
Should have BIM Function self folding
Net Capacity: 250 kg, Gross capacity: 500 gross. 100 gm
graduation. 1. Should have capacity at least
536 Kg
Should have portable air supply unit
Should have inflated height 8 inches
Should be made of nylon or lectrolite
Should have washable transfer pads
Should have length at least of 78 inches
Should be made of bacteria proof, water proof, static electricity
free and launder able material
Should have built in stabilization bands to contour patients
Should have santi-liner with non magnetic snaps
Should have patient security straps
Should have able Fully washable & easily dried.
Should have able Made of strong material and strong adhesive
topping to trap the
dust and not interfere with the walking.
Should reusable type.
Should work the whole year round and can be installed easily
with
the help of special adhesive supplied with mats.
Should contain a bactericide to reduce the footborne microbial
contamination by over 9%.
Should resistant to most chemicals. Should withstand working
temp. between 0°C- 50°C.
Should have able supplied with compatible detergent.
Should be Wall/Standing Model
The body should be 24 Inch X 19 Inch
There should be four stage of filtration
pre-filter
electrostatic Filter
Activated Carbon Filter
UV-ray sterilization
Large graphical LCD with date/time consumption of UVmadiation tube life.
low-noise centrifugal blowers
Two U.V light inside the body of the equipment, should not be
exposed to the naked eyes.
Purification area should be approximately 10ft. X 10 tt X 12 ft.
AIR MATTRESS FOR BED SORE PREVENTION TUBE TYPE
6-8” tubes, should have facility to change single tube, with
polyuetherane covering for easy cleaning the pump should be
67
130
131
132
Forcep for skin stapler
DOPPLER WITH TWIN
MONITORING
FINGERTIP PULSE
OXIMETER
133
Laparoscopic Humidifier
light wt. with capacity to deliver air at 3-5 ltr per min. should
have alarm for low pressure and power failure.
Forcep for application of absorbable skin stapler
Doppler With Twin Facility Having Two Probes For Twin
Monitoring Simultaneously With Two Display At A Time
Should have color display for pulse rate and SPo2. should
have bar and wave form display. Should have different size for
paeds. And adult finger.
it should have sterile heated limb with dual heating element to
maintain temperature and humidity all the way to the patient.
The outer tubing provides insulation and aids flexibility. Tubing
is connected with a standard male luer lock connector with
swiveling lock for easy connection to any laparoscopic probe.
should contain a humidifier chamber
Should have dry tubing for connection from Insufflator to
humidifier chamber, filter.
Should have male to male connector to connect filter to heated
limb to purge air from tubing before entry to patient.
134
Laminar Air Flow
135
Chair Cum Trolley
Stretcher
Should be automatic loading stretcher with capacity to covert
into wheel chair
Should have completely overturnable side protections
Should have loading capacity 160-180
Approx size 190 X 56 X 82-85 cm
136
Makler Counting Chamber
137
Instrument & Medicine
Cabinet
138
High Pressure Vertical
Steam Sterilizer
Should be made from SS
Should have lockable doors
Should have adjustable sS/Glass shelves
The machine should covered with stainless steel sheet for
aesthetics and convenience.
Should have digital time & temperature controller.
should have choice selection of rapid or natural cooling or
drying
Should have CE marked.
139
Cryo Container
140
Pneumatic Curtain
141
O.T. Light (ceiling) with
doom with camera and LCD
arm (Single/Multipal Doom)
Should assist in maintaining a turbulence free environment
when every time the door is opened. Should create an invisible
curtain to contain the movement of dust/microbes/bacteria etc.
when the door is opened or left opened. Should be designed
with the latest air barrier technology. Should give thick air
curtain with suitable air capacity as per the size of the door.
Should also maintain a high level of cleanliness by removing
the possibility of dust particles from entering the clean
environment.
Should work on single phase, 220V, 50Hz, AC supply.
Should be constructed from CRC sheet heavy duly powder
coated.
Should work on the heavy duty centrifugal technology using
well balanced blowers.
Should conserve energy by prohibiting temperature loss in
controlled atmosphere areas.
Should be provided with clamps for mounting. The
manufacturer should be ISO & WHO-GMP certified. The
product should be CE Marked.
Should have high resolution Video Camera
Should have shadowless effect and focusing depth
Compatible with laminar air flow in the O.T.
Should have stable electric performance
68
Should have backup build changeover system
CE Marked
Consumables for Gynae
S.No.
1
Name of Item
System pack for Sterigen SG400
2
SELF RETAINING
RETRACTOR
3
I.D BANDS
4
HAND PORT SYSTEM
5
DIRECT DRIVE GRASPER
6
SEPARATOR 5MM WITH
TROCAR
7
SEPARATOR 12 MM WITH
TROCAR
8
SEPARATOR 11MM WITH
TROCAR
9
SEPARATOR 15MM WITH
TROCAR
10
DISPOSABLE TIP NON
BLADED TROCAR SYSTEM
12MM
Specification
Disposable self retaining retractor,Must provide 360 degree
retraction,Must have the ability to prevent abdominal wall
contamination,Must have the ability to adjust as per the wall
thickness
Transparent pu material for excellent conformability
it should be made of nylon or any good material with facility to
write name age sex and ward no.
Gel based hand access device,Must have gel based seal
only,Must provide 360 degree retraction,Should not strangle
hand and allow free movement,Side locking mechanism for gel
cap,Must allow insertion of trocar thru seal cap even hand is
inserted
Disposable atraumatic grasper with mesh covered ptica jaws,
Must be disposable 5mm
Wide opening jaws with mesh covered polymer pads for 100%
atraumatic grasping
One finger tip ratchet design for smooth locking
Disposable sequential helical tip non bladed trocar 5mm, Must
have a sequential helical design for total atraumatic insertion,
Must not have any type of metallic or plastic blades on the
obturator, Must have seal tabs for easier removal of specimen
and rapid desufflation
Shielded septum design for prolonged use.length-55mm,
100mm, 150mm
Disposable sequential helcal tip non bladed trocar 12mm, Must
have a sequential helical design for total atraumatic insertion,
Must not have any type of metallic or plastic blades on the
obturator, Must have seal tabs for easier removal of specimen
and rapid desufflation, Shielded septum design for prolonged
use , Universal seal to accommodate any 5 mm to 12 mm
instrument.length-55mm,100mm,150mm
Disposable sequential helical tip non bladed trocar 11mm, Must
have a sequential helical design for total atraumatic insertion,
Must not have any type of metallic or plastic blades on the
obturator, Must have seal tabs for easier removal of specimen
and rapid desufflation
Shielded septum design for prolonged use.length55mm,100mm,150mm
Disposable sequential helical tip non bladed trocar 15mm, Must
have a sequential helical design for total atraumatic insertion,
Must not have any type of metallic or plastic blades on the
obturator, Must have seal tabs for easier removal of specimen
and rapid desufflation
Shielded septum design for prolonged use. Length100mm,150mm
Must have spaceguard technology, Must have the ability to
minimize the trocar entry before ptical tions to avoid injury,
Must have the ability to release the abdominal vacuum upon
3mm entry, Must have scope lock and pneumo seal for scope,
Must have a sequential helical design for total atraumatic
69
insertion, Must not have any type of metallic or plastic blades
on the obturator, Shielded septum design for prolonged use,
Universal seal to accommodate any 5 mm to 12 mm instrument
length 100mm and 150mm
11
DISPOSABLE
LAPAROSCOPIC SCISSOR
WITH DUAL CUTTING EDGE
must be hand sharpened for excellent cutting edge
must have dual cutting edge for cutting different type of tissue
blades should be made of 400 series stainless steel only for
prolonged life and heavy usage
sizes of 35 cm and 45 cm
12
12 MM HASAN TROCAR
must have 12mm blunt tip trocar ptica type, must have
universal seal, two layered universal seal, lowest housing
profile, only non-bladed ptical tip
13
VASCULAR CLAMPS
DISPOSABLE INSERTS
14
Gel port Ballon trocar
The inserts should disposable and interchangeable
the inserts should made of mesh covered latis material to
provide full atraumatic grasping
in various sizes varying from 30mm to 90mm straight, curved
and sidebite
must provide different design combinations for different
vessels.
Gel port Ballon trocar system 12mm length-100mm,150mm
15
Oxidised cellulose
Normal weaving, all size
Thick weaving, all sizes
16
Delivery Kit
Dripping Sheet (Antibacterial), Lithotomy sheet
(With Leggings & Funnel Attached), Draper, Cord
Clamp(2pcs.),
Gynae Pad(5pcs.)
17
Caesarean Kit
OT Gown,Face Mask, Frill Cap, Gynae Surgi Sheet
(150cm X 200cm-sheet, 15cm X 20cm-incise area), Plain
Drape,
Hydrophilic Lint Free Sponge with radio opaque wire(3pc),
Surgical Pad with Adhesive
18
Surgical Pad
Hydrophilic, Lint free, Sterile Surgical Pad, with & without
adhesive, size-10cm X 10cm, 10cm X 20cm, 5cm X 5cm
(Pad) & 7.5cm X 7.5cm (Adh.),7.5cm X 7.5cm (Pad) & 10cm X
10cm
(Adh.), 5cm X 10cm (Pad) & 7.5cm X 12.5cm (Adh.)
19
20
21
Baby Kit
Trolley Cover
Antimicrobial sealant
22
Sterile Wrap
23
Finger squeeze alcohol based
Anti Bacterial processed Baby Cap,Nappy,Shirt & Mattress
with wraparound & PVC Lining, with mosquito net for face
Trolley Cover (Tyvec), Impervious & Autocleavable,
size-27” X 36”, 36” X 54”
Antimicrobial sealant intended for use prior to surgical incisionnon-flammable,latex free, non irritating and non-cytotoxic.
Coverage area: 25cm*25cm and 50 cm * 25 cm. individually
packed.




SMMS fabric
water resistant,
flame resistant
LOW linting
Compatible with Steam EO and Plasma, All size
Finger squeeze alcohol based hand sanitizer which may be
70
hand sanitizer
worn/put on belt.
It should be in a cartridge with an integrated no drip valve.
Capacity should be enough for one full work shift
24
25
Disposable Vomit bags
Instrument cleanser
Made of biodegradable material having closing facility.
100 gm solution contains non ionic surfactant & alkyl dimethyl
benzyl ammonium chloride.
26
27
Anti microbial hand & skin
cleansing lotion
Mild cleaning foam for
prevention & management of
bedsores
28
Antimicrobial skin gel with
ethyl alcohol 75%.
29
SHARP CONTAINERS
contains aqua sodium lacerceth seelfate, sodicem cbloride,
alcohol denat, disodium cocoanphodiacetate PEG 200 glyceryl
Should contains: aqua, alchohal denat, sodium laureth, PEG-7
glyceryl, cocoatedibuthyl adipate, farnesol, sorbic acid.
Disposable and unpeiercable round containers of various sizes
-
Shutter Blade Lids with needle removing provision.
Should be made of ecological plastic material and
polypropylene copolymer
colored with master batch without heavy metals and
cadmium.
Thickness should be 1.6 mm bottom and sides. 1.8mm
lid and closure.
30
31
32
33
Umbilical Clamps
Disposable abdominal
drainage system
Female urine catheter
Surgical Pad (Sterile)
34
Gauze Swab
35
Gauze swab X-ray Detectable
min.
Should be suitable for autoclave at 134 degree for 25
-
Should must have quality standard NF mark/FDA
approval & Should comply to ADR Norms.
It should be female metallic Urine catheter
Dressing pads sterile made of non-woven spunlace fabric at
least 30gsm
Size 10 X 10
10 X 15
10 X 20
Made of non-woven spunlace fabric at least 30 gsm
sizes 10 X 10 X 8
7.5 X 7.5 X 8
5X5X8
Made of non-woven spunlace fabric at least 30 gsm
should be x-ray detectable.
sizes
10 X 10 X 8
7.5 X 7.5 X 8
71
5X5X8
36
37
Abdominal sponges with X-ray
detectable
Catherization tray
38
Antivirus Kit
39
40
41
42
43
44
45
46
47
Sperm Wash
Sperm Filter
Sperm Cryo
Tissue Culture Medias
Vaginal Speculum
Centrifuge Tube
Semen Collection Container
Cryovials
IUI Catheters (Different Sizes)
48
49
Pasture Pipette
Cesarian/Abdominal Fluid
Collection Drape
50
Under Buttock Drape
51
Skin stapler
52
Disposable bed linen
53
Dressing Kit (major)
54
Dressing Kit (miner)
55
Stitch Removal pack
56
57
58
Abdominal sponges with X-ray detectable
Should be made of non-woven spunlace fabric at least 30gsm
sizes
25 X25X 4 & 6 PLY
30 X30X 4 & 6 PLY
35 X35X 4 & 6 PLY
Operation Kit (major)
Minor Operation /Procedure
Kit
Electrosurgical Pencil with
Lead
It should contain foley’s catheter, plastic forceps, cotton balls
pre-filled 20 ml syringe , lubricant, urine bag, test tube -1,
gauze pad, tenestratel drape, gloves, kidney shape basin
Flip tip endotractal tube & non woven swab.
Should have antivirus apron, Cap, Mask, Shoe Cover, Gloves,
Goggles,
Cesarian/abdominal fluid collection drape,
(254cm*183cm*305cm), having 33cm*33cm adhesive incise
area,360 degree fluid collection pouch,foam band, with suction
port,having tube holders and armboard covers.,sterile.
Under Buttock Drape with fluid collection pouch, 102cm*112cm
with absorbent pad, sterile.
Subcuticular absorbable skin stapler containing 25 polyglactin
pins.
Should made up of nonwoven spunlace fabric, 40 gsm
laminated with 12 micron LDPE, color : blue, green, and white.
Size should be 6ft x 3.5 ft
It should contain dressing forcep, tray with gallipots, cotton
balls, gauze swabs, absorbant dressing pad 4”x4”, hand wipe
tissue,disposable bag
It should contain dressing forcep, cotton balls, gauze swabs,
absorbant dressing pad 2.5” x 7”, hand wipe tissue,disposable
bag
It should contain dressing forcep, cotton balls, gauze swabs,
absorbant dressing pad 2.5” x 7”, hand wipe tissue,disposable
bag,, long stitch cutter with handle.
Should contain gown, trolley sheet , drape sheet , drape
sheets, abdominal sheet, absorbant dressing pads, paking
rolled gauze, abdominal sponges, operatingpeanuts, cotton
balls, gauze swabs kidney tray, bowls, hand-wipe tissues,
disposable bag
Should contain sterile drape , dressing forcep, tray with
gallipots, cotton balls, gauze swabs, absorbent dressing pad ,
hand-wipe tissues, disposable bag
hand operated, with removable non stick electrode, with cable.
72
Tender Group No. IX
Radiology Department
S.No.
1
2
3
Name of Item
Barium Enema Equipment with complete
Accessories
Cassette Box of all sizes
Chest Stand
4
Intensifying Screen for cass ettes of
following sizes
5
6
Lead Apron (all sizes)
Lead Goggles (Front & side), for
fluroroscopy
Lead Marker 0 to 9 (size 3/4")
Lead Marker A to Z (size 3/4")
Lead Screen (3 Panel) for Prevent ion of
radiation for dental x-ray machine
Lead Skirt and Vest Set
Light Weight Zero Lead Aprons
7
8
9
10
11
12
Specification
Floor Model & Heavy duty with auto loc king
arrangements
a) (size 17" x 14")
b) (size 14 x 14)
c) (size 12 x 15)
d) (size 10 x 12)
e) (size 10 x 8)
f) (size 6 1/2 x 8 1/2)


























X-Ray & Imaging Film Digitizer System








73
Product quoted should be lead free and
international certification
Radiation protection apparel should
incorporate high quality protection sheet of
even thickness and uniform distribution of
lead.
Protection sheet should be flexible and not
prone to cracks and pin holes.
Lead bonding and PVC /Rubber to create
protective sheeting composition should be
lead minimum 80 and PVC/Rubber 20. Ratio
should be 80:20
Weight should not exceed 3.3 kg /Sq.m.
Lead equivalence of 0.5mm (pb)
All models should have anti skid pads
resulting in comfort of wearing over
shoulders.
Belt should be provided inside to avoid back
stress.
Side cuts should be there for ease of
movement (walk)
X-Ray and imaging film digitizer system for
digitization of X-Ray, CT-Scan, Ultrasound &
MRI films.
It should accept all the film sizes ranging
from 5” x 7” to 14” x 17”.
Scanning should be based on Professional
µ
Lens CCD technology.
The gray scale resolution s hould be
minimum 16 bits.
The scanning speed should be less than 18
seconds for 14” X 17” film size.
The spatial resolution should be 40800
pixels/line (approximately).
The optical density of the system should be
upto 3.2D.
13
‘X’ ray film of various sizes
14
X – Ray view Box
(Single Double & Triple Panel)
15
Image Work Station
16
X-ray film Digitizer
 Scanner should have USB hardware
 interface.
 It should be capable of storing scanned
 images in DICOM, JPEG and BMP format.
 The output DICOM format image should be
 compatible with PACS network .
 The digitizer should have a work station
 having 17” LCD & should be capable of
 processing image data of the scanner.
 It should have a DVD writer, 1 Gigabytes
 Ram, 100 Gigabytes storage.
 It should have post process ing facilities lik e
 windowing, scaling, multi-graphics
 processing, image division functions, image
 flipping & rotating, Image zooming,
 annotation, measurement, Cropping, cine
 play, text writing, Edge detection, gray
 equalization, contrast equalization.
 It should be compatible with DICOM film
Sizes are ;
6½“X8½“
8” X 10”
10” X 12”
12” X 15”
14” X 14”
14” X 17”
Fluorescent View Box - Specially ultra thin panel XRay Film View Box Using External Electrode
Fluorescent Lamp Technology,
Suitable For Viewing Film Size Up To 14"X17",
Light Weight And Slim With Panel Thickness Not
More Than 1.5 Inches,
To Provide A Uniform Light Pattern With An Output
Ranging Between 7000 To 12,000 Lux.
The life span should be 20,000 Hrs or more.,
Easy insertion and removal of films with a automatic
switch which turns on with the insertion of the film
and turns off when the film is taken out.
It should have adjustable brightness control and
flicker free high frequency light for reduction of eye
strain.
work station having a high resolution 2 Mega pixel
or more monitor with 2GHz processor, CD/DVD
recorders, 200GB or more HDD, software capable
of capturing image from DICOM compatible
equipments and route the images to other locations,
for advanced image processing and documentation.
Unit should have scanning mode-16 ft gray scale,
12 to 8 bit conversion(256) optimize grey level.
Scanning speed 300 epi (4x4k) 30 sec.. and 150 dgi
2x2 k 12 sec, integrated light box, scanned and
original images can be compared immediately..
Large media size – upto 14” x 17”
DICOM – 3.0 interface for DICOM complience
system, PACS and tele radiology, power supply100 – 250 AC
COMPUTER – it should be supplied with CPU ,
Pentium IV/ intel duo core, minimum 1 GB RAM,
window HP, video card 64 MB supported modem,
network card for DICOM, 240 GB hard disk, dual
interface – fire wire or high speed USB interface, fire
74
wire card and cables.
75
Tender Group No. X
Refilling of Medical Gases
S.No.
Name of Item
01
Oxygen Cylinder “A” Type
02
Oxygen Cylinder “B” Type
03
Oxygen Cylinder “D” Type
04
Nitrous Oxide “A” Type
05
Carbon diOxide Cylinder
76
Download