GOVT. OF NCT OF DELHI OFFICE OF THE MEDICAL SUPERINTENDENT SHRI DADA DEV MATRI AVUM SHISHU CHIKITSALAYA, DABRI, DELHI-110 045 TENDER NOTICE Sealed tenders are invited from licensed manufacturer/supplier having Delhi Sales Tax Registration Number/TIN for entering into running Rate Contract for supply of various consumable and non-consumable items under various Groups to SDDMSC, Dabri, Delhi for a period of one year from the date of issue of Rate Contract which may be extended further till the next rate contracts are awarded. S.No Group No. 1. 2 Group - I Group - II 3. 4. Group - III Group - IV 5. 6. 7. 8. 9. 10. Group - V Group - VI Group - VII Group - VIII Group - X Group - XI Name of the Group Drugs & Medicines General Surgical Consumable (including Sutures & Dressing Material) Lab Consumable & non consumable General Items, Stationery & Linen (Consumable & Non-Consumable) Anesthesia (Consumable & Non-Consumable) Medicine (Consumable & Non-Consumable) Pediatrics (Consumable & Non-Consumable) Gynae (Consumable & Non-Consumable) Radiology (Consumable & Non-Consumable) Medical Gases EMD (In Rs.) 50,000.00 50,000.00 50,000.00 50,000.00 50,000.00 50,000.00 50,000.00 50,000.00 25,000.00 25,000.00 The tender form can be obtained from Procurement Branch, SDDMSC, Dabri, Delhi w.e.f. 05.10.2009 upto 04.11.2009 on any working day between 10.00 AM to 1.00 PM on payment of Rs.500/- in the form of DD in favour of “Medical Superintendent, SDDMSC, Dabri, Delhi”. The Tender Notice is also available on website of Govt. of Delhi, www. delhi govt.nic.in and can also be downloaded. In case of downloading, tenderer will have to deposit a draft of Rs.500/- alongwith tender form by Demand Draft drawn in favour of Medical Superintendent, SDDMSC, Dabri, Delhi. For obtaining the tender form by post, the tenderer should apply with a self addressed envelope size 35cm x 25cm along with demand draft of Rs. 100/- as postal charges etc. in addition to the tender cost of Rs. 500/-. The tender document complete in all respect along with the Earnest Money in the form of Fixed Deposit Receipt (for 2 years) for Rs. 50,000/- for Group I to Group VIII and Rs. 25,000/- for Group IX to Group X in favour of Medical Superintendent, SDDMSC, Dabri, Delhi should be put in a tender box placed in the Office of Medical Supdt, SDDMSC, Dabri, Delhi, Delhi by 2.00PM on 04.11.2009. Tender received through post or after due date and time will not be accepted. The tender process involves of 02-stage scrutiny - technical bid and price bid. The technical bid will be opened on 04.11.2009 at 2.30 PM in presence of tenderer or their authorized representative who choose to be present on the occasion. Price bid of technically qualified tender will be opened later, for which date, time & venue will be intimated to technically qualified tenderer separately. The tender will be valid for 01 (one) year from the date of issue of Rate Contract; however it can be extended further on mutual consent and satisfactory performance by the agency. Medical Supdt., SDDMSC, Dabri, Delhi has the full and exclusive right to accept or reject any or all the tenders without assigning any reasons and also to cancel the supply order at any time. MEDICAL SUPERINTENDENT SDDMSC, DABRI, DELHI 1 GOVT. OF NCT OF DELHI OFFICE OF THE MEDICAL SUPERINTENDENT SHRI DADA DEV MATRI AVUM SHISHU CHIKITSALAYA, DABRI, DELHI-110 045 Issued to M/s……………………………..….. Cost of the tender Rs.500/(Non-refundable) Tender due on : 04.11.2009 For Procurement of items under Group No._____ TENDER FORM Sealed tenders are invited from licensed manufacturer/supplier having Delhi Sales Tax Registration Number/TIN for entering into running Rate Contract for supply of various consumable and non-consumable items to SDDMSC, Dabri, Delhi, for a period of one year from the date of issue of Rate Contract which may be extended further till the next rate contracts are awarded. The tender form can be obtained from Procurement Branch, SDDMSC, Dabri, Delhi, w.e.f. 05.10.2009 upto 04.11.2009 on any working day between 10.00 AM to 1.00 PM on payment of Rs.500/- in the form of DD in favour of “Medical Superintendent, SDDMSC, Dabri, Delhi”. The Tender document is also available on website of Govt. of Delhi, www.delhi govt.nic.in and can also be downloaded. In case of downloaded tender, tenderer will have to deposit a draft of Rs.500/- along with tender document in the form of Demand Draft drawn in favour of “Medical Superintendent, SDDMSC, Dabri, Delhi”. For obtaining the tender document by post, the tenderer should apply with a self addressed envelop size 35cm x 25cm along with demand draft of Rs. 100/- as postal charges etc. in addition to the tender cost of Rs. 500/-. The tender document complete in all respect alongwith the Earnest Money in the form of Fixed Deposit Receipt (for 2 years) for Rs. 50,000/- for Group I to Group VII and Rs. 25,000/- for Group XI to Group X in favour of “Medical Superintendent, SDDMSC, Dabri, Delhi” should be dropped in tender box placed in the Office of Medical Supdt, SDDMSC, Dabri, Delhi, by 2.00 PM on 04.11.2009. Tender received through post or after due date and time will not be accepted. The tender process involves of 02-stage scrutiny - technical bid and price bid. The technical bid will be opened on 04.11.2009 at 2.30 PM in presence of tenderer or their authorized representative who choose to be present on the occasion. Price bid of technically qualified tender will be opened later, for which date, time & venue will be intimated to the technically qualified tenderer separately. The tender will be valid for 01 (one) year from the date of issue of Rate Contract; however it can be extended further on mutual consent and satisfactory performance by the agency. Medical Supdt., SDDMSC, Dabri, Delhi has the full and exclusive right to accept or reject any or all the tenders without assigning any reasons and also to cancel the supply order at any time. The following terms and conditions should be read carefully and complied with before submitting the tender. 1) TERMS AND CONDITIONS Tenders should be prepared in two separate envelopes Technical bid and Price bid. a) Technical Bid containing original Performa for SDDMSC Open Tender dully filled in and signed, Earnest Money Deposit and copies of required documents. Irrelevant/uncalled document need not to be enclosed with the Technical Bid. b) Price Bid containing prescribed schedule to quote the rate duly filled in and signed without overwriting, neatly written. Further these two sealed envelopes of Technical Bid and Price Bid must be kept in single envelope super scribed as SDDMSC OPEN TENDER FOR SUPPLY OF ITEMS UNDER GROUP…….., Due Date and Name & address of tenderer. PLEASE NOTE THAT PRICE SHOULD NOT BE INDICATED IN TECHNICAL BID, OTHERWISE THE BID WILL BE DISQUALIFIED. 2) Tender should be preferably typed and the rates be quoted in words AS WELL AS IN FIGURE without any overwriting or erasing which will render the tender of that particular item invalid. 3) The tenderer is bound to submit an undertaking as per Performa attached on non-judicial stamp paper of Rs. 100/-(one hundred) only. 4) Covering letter should clearly indicate the list of the items quoted and enclosures. 5) Only one model/brand to be quoted against each item. If more than one model/brand is quoted, the item will not be considered for technical/Price Evaluation. 6) Each paper of the tender must be numbered and signed by the tenderer with the seal of the firm and all photocopies of original documents must be attested by Gazetted Officer/Notary/. 7) The rates quoted should be exclusive of VAT. The rates of Sales Tax (State & Central) chargeable may however be given separately. 2 8) Each tender must be accompanied by a fixed deposit receipt valid for two years forRs.50,000/- (Rupees Fifty Thousand) Only for Group I to Group VIII and Rs. 25,000/- for Group IX to Group X as an Earnest Money Deposit/Security deposit pledged in favour of Medical Supdt., SDDMSC, Dabri, Delhi, payable at New Delhi. No cheques/Postal Orders/Money Order/ Cash Payment will be accepted. Govt. undertakings and Small Scale Industries are exempted from submitting the Earnest Money. However, if the rate contract holding firm fails or neglects to observe or perform any of his obligations under the contract, it shall be lawful for the purchaser to forfeit the earnest money deposited. Earnest Money deposit of the successful tenderer will be kept as the security deposit against the tender, which will be released two months after the successful completion of the Rate Contract. 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) 21) 22) 23) 24) The tenderers must attach Photostat copy of Sales Tax Registration/TIN Certificate duly attested by any Gazetted Officer/Notary/Self. Failure to submit the STRC/TIN will render the tender invalid automatically. The tenderers must attach self attested Photostat copy of PAN of the firm (in case of partnership/public limited co.) or individual PAN (in case of sole proprietorship along with certificate in this regard). In case of Drugs/Medicine, the tender should quote only those items for which the manufacturer is having valid WHO GMP Certificate /Revised Scheduled M Certificate and attested copy of the same issued by the drug controller of the concerned State indicating the date of validity /current valid certificate along with a list of product registered should also be submitted. Pharmacopeia specification: IP/BP/USP etc. should be clearly mentioned against each drug /constituent of the drug quoted as per the provision of the Drugs & Cosmetic Act. In case of equipment, catalogues with detailed specifications must be submitted with the technical bid. However at the time of approval of tender the technical committee can ask for samples / demonstration. Samples will be received in the respective Stores. In case of items without catalogue, sample should be submitted in the concerned store By 04.11.2009. No sample will be received after 04.11.2009. Every sample should be tagged with the slip mentioning the name of the firm, Group .No. & Sl.No. of the tender and name of the item. After finalization of the tender the firm must remove the unapproved item within 15 days, failing which the sample will be disposed off without further reference to the firm. Approved samples will be kept in the store concerned till the validity of the rate contract. The firm/tenderer should not be blacklisted in the past by any Govt./Pvt. Institution. Delivery period: The supplies have to be made within 30 days (for indigenous item) and 90 days (for imported items) from the date of issue of the supply order, failing which the order is likely to be cancelled. The time or/and date of delivery of equipment stipulated in supply order shall be deemed to be essence of contract and delivery must be completed in stipulated period. However in exceptional circumstances and at written request before expiry of delivery period, extension of date of supply can be considered for further 15 days of indigenous items and 30 days for imported items. Grant of extension of supply period is at the sole discretion of Medical Superintendent. The delivery of goods can be accepted after expiry of delivery/extended period with penalty of 5% of the value of order for every delayed week or part of week, subject to maximum of 10% depending on the requirement of the hospital. The firm will be bound to supply the equipment/store with in stipulated /extended period, failing which the supply order is likely to be cancelled and EMD/Security Deposit will be forfeited and/or firm may be blacklisted. Store shall be marked with the words in CAPITAL AND BOLD LETTERS ‘NOT FOR SALE – FOR SUPPLY TO GOVT.OF NCT OF DELHI’. The store supplied should have adequate expiry period and should not passed 1/6th of self life. The hospital has right to send the sample(s) from consignment received for testing. If the product is found not of standard quality, the total cost of the test will be recovered from the supplier. The supplier will have to replace the entire consignment irrespective of the fact that part of the stores supplied may have been consumed. All rejected store shall in any event remain and will always be at the risk of the supplier. In case, tenderer is the sole distributor of a particular item he should submit authority letter in support of the same from the actual manufacturer. In case tenderer is selling agent of a particular item he should submit an authority letter in support of the same from the actual manufacturer/sole distributor concerned. Failure to submit the authority letter of a particular item may render the tender invalid for that particular item. If the Principal Manufacturer/sole distributor withdraws its distribution ship from the tenderer during validity period of approved rates, Medical Superintendent has full right to cancel the eligibility of tenderer. The tenderers are bound to supply the store during the validity of tender at the approved rates. The validity of the tender will be for the period of one year from the date of issue of Rate Contract. However, 3 25) 26) 27) 28) 29) 30) 31) 32) 33) 34) 35) 36) 37) 38) the contract can be extended further up to another 01 year subject to satisfactory performance of the firm and on mutual consent. Tender form is non-transferable. The payment will be made after the receipt of the item and completion of all codal formalities. No advance payment will be made. If `D' form is required, it will be provided by the concerned office subject to the production of necessary documents thereof. While quoting rates S.No. of the tender list must be indicated and rates should be quoted in the same S.No./order as given in the tender list The price quoted should be in Indian currency only. The price quoted should not exceed the MRP/prevailing market price/rate quoted in another Hospital under Govt. of NCT of Delhi in the same financial year. In case of equipments / machines having cost below Rs.2.0 Lacs, the tenderer will give comprehensive guarantee for 24 months. He will maintain the equipment / machine during this period and replace spare parts at free of cost, if necessary. The tenderer should be in position to provide the AMC services, spare parts and consumable for 3 years, after 2yrs guarantee. Repair of equipment/ machine is to be carried in the hospital premises where it is installed. In case the equipment / machine is to be shifted to the manufacturer workshop for repair, to & fro transport charges are to be born by the tenderer. The Tenderer shall ensure that down time is minimum & shall have to supply standby unit in case of undue delay in public interest. However in case of equipment costing more than Rs.2.0 lacs each, the tender will submit comprehensive guarantee/warranty from the manufacturer for a period of 60 months including spares. For the next 60 months the firm shall provide free service and shall charge for the spares, if any. The firm should submit bank guarantee of 10% of the cost of the equipment costing more than Rs.2.00 lacs (valid for 05 years) and indemnifying the hospital against all losses incurred by the hospital during the guarantee period. Instruments and other items with certification will be preferred. Attested copies of certification like CE/FDA/BSI etc. should also be submitted wherever necessary. Post tender negotiation will not be allowed. The decision of Medical Superintendent regarding approval of sample/item shall be final. The tenderers must attach a soft copy of technical Bid alongwith the hard copy of the technical bid in form of CD. The courts of Delhi shall alone have jurisdiction to decide any dispute arising out of or in respect of the contract. MEDICAL SUPERINTENDENT SDDMSC, DABRI, NEW DELHI 4 To be enclosed with technical bid UNDERTAKING (On non-judicial stamp paper of Rs.100/-) Open Tender for Supply of Items under Group____________ Date of opening_______________ The undersigned undertake with Medical Superintendent, SDDMSC, Dabri, Delhi to declare and accepts as follows: 1. It is certified that I/We…………. s/o…………… r/o……………. am sole proprietor/partner/director of the firm M/s………………………….. 2. The undersigned declare that I/We have gone through the terms & conditions mentioned for the above and undertake to comply with them. The rates quoted by me/us are valid and binding on me/us for acceptance for the period of one year from the date of issue of Rate Contract and in extended period, if any. 3. I/we undersigned hereby bind myself/ourselves to the Medical Superintendent, SDDMSC, Dabri, Delhi to supply the items for SDDMSC, Dabri , Delhi for or on behalf of the Lt. Governor of Delhi during the period of contract. The exclusive showing the rates quoted by me/us for the items tendered for are specified against each. 4. The article shall be of the best quality and kind as per requirement of the institution. The decision of the Medical Superintendent, SDDMSC, Dabri, Delhi (herein after called the said officer) as regards to the quality and kind of article shall be final and binding on me/us. 5. Earnest Money deposited by me/us viz. in the form of FDR for 02 years, pledged in favour of Medical Superintendent SDDMSC, Dabri, Delhi is enclosed herewith and shall remain in custody of the Medical Superintendent, SDDMSC, Dabri, Delhi till the successful completion of the rate contract as security/performance deposit. 6. If I/We fail to supply the article within the stipulated time as per terms & conditions of the tender, the Medical Superintendent, SDDMSC, Dabri will have full right to forfeit the security deposited by me/us, cancellation of contract and/or blacklisting of firm. 7. If any items/articles supplied found of inferior quality it shall be replaced by me/us immediately failing which I/we shall be liable for forfeiture of Security Deposit deposited, cancellation of contract and/or blacklisting of firm. 8. There is no vigilance case pending against the firm / supplier. 9. I/We hereby certify that my/our firm has not been blacklisted in the past by any Govt. /Pvt. Institution. 10. I hereby undertake to supply the items during the validity of the tender as per direction given in supply order within the stipulated period. 11. In case of equipment costing less than Rs.2 Lacs I/We will provide comprehensive guarantee/warranty for 24 months and will provide free service for next 3 years and will charge only for spares. However, in case of equipments/ machines costing more than Rs.2.00 Lacs, I/We undertake to provide comprehensive guaranty/warranty from the manufacturer for a period of 60 months including spares. After 60 months, I/we will provide maintenance free of cost for another 60 months and will charge only for spare parts and accessories. I/We undertake to give post replacement guarantee/warranty of the parts replaced for minimum 06 months for the period beyond 60 months. 12. In case of equipment costing more than Rs.2.00 Lacs, I/We should submit a bank guaranty of 10% of the cost of the equipment indemnifying the hospital against all losses incurred by the hospital during the guarantee period. 13. The Medical Superintendent, SDDMSC, Dabri, Delhi has the right to accept or reject any or all the tenders without assigning any reason. 14. I/We agree to accept the amount of the bill to be paid by the purchaser after completion of all codal formalities and should any amount of the bill found by the audit office or Govt. of Delhi to have been over-paid, the amount so found shall be refunded by me/us. 15. I/we understand all the terms & conditions of rate contract and bind myself/ourselves to abide by them. 16. It is certified that the rate quoted by me are not higher than the M.R.P/prevailing market rate/rate quoted in other hospital under GNCTD in the same financial year. If it is found false, the firm may be penalized or blacklisted. 17. Certified that I/We have paid the Income Tax as assessed for the period ending………………. 18. Certified that I/We have paid the Sales Tax as assessed for the period ending on……………… and proof thereof is enclosed. 19. I shall also be responsible to pay all taxes as applicable to the Govt. like; Sales tax/VAT, Income tax etc. SIGNATURE OF THE TENDERER WITH STAMP 5 GOVT. OF NCT OF DELHI OFFICE OF THE MEDICAL SUPERINTENDENT SHRI DADA DEV MATRI AVUM SHISHU CHIKITSALAYA, DABRI, DELHI-110 045 8. Form SDDMSC, Dabri Annual Open Tender 2009-10 Name of the tenderer/firm: Full postal address: Telephone No. & Fax No. : Whether the tendering firm is manufacturer of items or supplier Name/Address of the Proprietor: Status of the Proprietor (Sole/Partnership/Public Ltd.) : Name of person who are responsible for conduct of business: Sl. No. Name Father’s/Husband’s Name Age Residential Address Name of Govt. Hospitals/institutions to which the tenderer already supplied the items 9. Has the tenderer ever been black listed by any Govt. agency? If yes, give details 10. Are any cases pending in the court related to any supplies? If yes, give details (attach separate sheet) 11. Registration No. of Sales Tax/TIN with copy of registration no 12. Whether Income Tax has been paid, if so Indicate the last period of assessment 13. Does the firm have the adequate facilities to check the quality? 14. Tenderer should enclose the required documents as per check list enclosed here with 1. 2. 3. 4. 5. 6. 7. I, ______________________________________________Prop./Partner/Director of M/s___________ _______________________________________________ hereby declare that the information given in this form is true & correct to the best of my knowledge & belief. I offer to supply the items mentioned in the schedule (enclosed in price bid) at the rates quoted therein. I agree to hold this offer for one year after finalization of rate contract. Yours faithfully Dated: Signature Name of tenderer…………………. Address……………………………. …………………………….. …………………………….. WARNING: - Subsequently, if information furnished in this form is found incorrect, the tender will be rejected and further tenderer will be black listed. 6 To be enclosed in Technical Bid GOVT. OF NCT OF DELHI OFFICE OF THE MEDICAL SUPERINTENDENT SHRI DADA DEV MATRI AVUM SHISHU CHIKITSALAYA, DABRI, DELHI-110 045 NAME OF FIRM TENDER FOR SUPPLY OF ITEMS UNDER GROUP………… LIST OF ITEMS QUOTED:S.No. S.No.as per tender Name of items Make/ Model Indian or Imported Sample (Yes/No) Catalogue Yes/No If required separate sheet may be appended. Signature_____________________ Name of tenderer_______________ 7 To be put in separate envelope superscribed “Price Bid” GOVT. OF NCT OF DELHI OFFICE OF THE MEDICAL SUPERINTENDENT SHRI DADA DEV MATRI AVUM SHISHU CHIKITSALAYA, DABRI, DELHI-110 045 Schedule to quote rates NAME OF FIRM_______________________ TENDER FOR SUPPLY OF ITEMS UNDER GROUP………… S.No. S.No. as per tender Name of items Make/ Model Rate per unit (In Rs.) Figures Words Tax Yes (%)/No Signature _____________________ Name of tenderer _______________ Note: 1. Rate quoted should be exclusive of VAT. Sales Tax Chargeable if any may be given separately. 2. Rate should be according to unit asked for. 3. Plea of clerical error, typographic error etc. would not be accepted. 4. In no case the rate quoted should be higher than the M.R.P. of that item. 8 GOVT. OF NCT OF DELHI OFFICE OF THE MEDICAL SUPERINTENDENT SHRI DADA DEV MATRI AVUM SHISHU CHIKITSALAYA, DABRI, DELHI-110 045 Check list of documents to be submitted in the technical bid: S.N. Name of the Document Yes/No 1 2 3 4 Tender Application Form in original Undertaking on Non-Judicial Stamp Paper of Rs.100/Duly filled & signed form for SDDMSC, Dabri Open Tender Earnest Money Deposit (EMD) for Rs. 50,000/- for Group I to Group VIII and Rs. 25,000/- for Group IX to Group X in the form of FDR valid for 02 years, pledged in favour of “Medical Superintendent, SDDMSC, Dabri, Delhi”. Sales Tax Registration Certificate (STRC)/TIN , DVAT Return PAN No. Return Authority letter from manufacturer/Distributor Drug License, if applicable Yes/No Yes/No Yes/No Yes/No 5 6 7 8 Page No Yes/No Yes/No Yes/No Yes/No Note: All above documents are mandatory for technical bid. Irrelevant/uncalled document need not to be enclosed with the technical bid. Signature of tenderer with seal 9 Tender Group No. I Tender for Medicines/Drugs (CPA Medicines/Drugs shall be procured only when CPA fail to make the supply) S.No. Name of Item 1 Antacid gel with MgOH+ALCL3+Activated, 200ml, Francosil MPS 2 Antispasmodic Drops Each ml contains Dicyclomine HCl IP10mg.,Activated Diamethacone IP , 40mg-10ml Bottle 3 Betamethosone + Gentamycin + Tolnaftete + Idochlohydroxyguinolone (0.61 mg + 1.00mg + 10.00mg + 10.00mg + 1.00mg) 4 Cap Anti Oxidant with selenium & copper (Vit.A, Acetate IP-5000 IU, Vit.E Acetate 25mg, Vit.C 100mg, Thiamine mononitrate 10mg, Riboflavine 10mg, Pyridoxin HCL 3mg, Cyanocobalamine 5mcg, Niacinamid 50mg, Folic Acid 1mg, Calcium Pantothenate 12.5mg, Zinc Oxide 40mg, Cupric Oxide 25mg, Sodium Selenate 60mcg, Manganses Chloride 1mg, Chromium Chloride 65mcg). 5 Cap Citrus Bioflavonoid Compound 150mg, Ascorbic Acid IP 75mg, Menadione IP 0.66MG, Ferrous Gluconate IP 67mg, Tri-Basic Calcium Phosphate IP 144.43mg. 6 Cap. Ferrous Succinate BP 200mg, Succinic Acid 210mg, Folic Acid IP 400mc g. 7 Cap Fluconazole, 150mg. 8 Cap Vitamin A 25000IU equivalent to retinal 7.5mg in water soluble form 9 Cap. Alphacalcidol B.P. 0.25mcg (1@-Hydroxyvitamin D3), Calcium Carbonate I.P. 500mg 10 Cap. Paracetamol 400mg + Dextropropoxyphen HCl 65mg 11 Carbonyl Iron, Zinc Gluconate, Vit. B12 and Vit. E, Selnium and Folic Acid Syp 12 Cough syrup - Each 5ml contains : Dextromethorpan Hydrobromide IP 7.5mg, Centrizine Hydrochloride BP 2.5mg, Zinc, Gluconate USP, Equivalent to Elemental Zinc 7.5 mg, Menthol IP 1.5mg, Flavoured Syrupy base q.s 13 Cream Anti Inflamatory, containing: Nimusulide 10mg, Methyl Salicylate IP 100mg, Menthol IP 50mg, Capsaicin USP 0.025mg, 30gm, 14 Cream Silver Sulphadiazine Jar, 500gm 15 Drops Iron (each 1ml containing) - Colloidal Iron, equivalent to elemental Iron 25mg + Lysine HCL 200mg + Vit.B12 5mcg + Folic Acid 200mcg - 15ml bottle, 15ml 16 Each 5ml contains - Terbutaline Sulphate IP 1.5mg. Ambroxol Hydrochloride BP 15 mg, Guaiphenesin IP-50mg, Zinc Gluconate USP, Equivalent to Elemental Zinc 7.5mg, Menthol IP 0.5mg, Flavoured Syrup base q.s. 17 Each 5ml contains : Paracetamol IP 125mg, Phenylephrine Hydrochloride IP 2.5mg., Cetirizine Hydroc hloride BP 2.5mg, Zinc Gluconate USP, Equiv. to Elemental Zinc 7.5mg, Flavoured Syrup base q.s 18 Enteral Nutrition powder containing Carb, Fat, Protein) -57 Gm Sachet, 57gm 19 Ferric Ammonium Citrate-160mg(equal to elemental iron 32.8mg) + Cyanocobalamin-7.5mcg + Folic Acid-0.5mg, 200ml 20 I/V Omega 3 Fatty Acid a) 10% fish oil emulsion with a high percentage of omega-3, fatty acids eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA). b) The polyunsaturated omega-3 fatty acids EPA and DHA serve as precursors of anti inflammatory eicosanoids and for cell membrane assembling 21 Infusion Aminoacid solution for parentral nutrition (40% Amino Acid+80%Glucose with option of lipid addition port in bag), Celemin 10 plus 200ml, 22 syp. methdilazin2.5mg+amounim chloride .1mg+ sodium citrate 50mg 100ml 23 Inh. Halothane 24 Inh.Isoflurane. 100ml bottle 25 Inj Trimethoprim and sulfamethoxazole 80 & 400 mg 26 Inj Adrenaline (1:10000), 1ml 27 Inj Amidorone 10 Remarks 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 Inj Aminophylline, 10ml, Inj Amoxicillin +Clavulanic acid 1.2 Gm, Inj Ampicillin, 500mg Inj Anti D 300 mg Inj Botropsae, 1ml, Inj Calcitrol, 1mcg Inj Calcium Gluconate, 10ml, Inj Cefaparazone 1gm + Salbactum 1gm Inj Cefotaxime 1gm Inj Dextrose 10% Inj Dextrose 25% 25 ml Inj Dextrose 5% Inj Dextrose 5% with Saline 0.9% Inj Digoxin Inj Dobutamine 250mg/ 5ml Inj Ethamsylate, 250mg/2ml Inj Frusemide, 2ml Inj Hydrocortisone Acetate 2ml, 1ml (vial) Inj. Glycerly Trinitrate 5ml ampule Inj Imipanam 500mg Inj Insulin (Human) Cartridges- Mixtard(30/70) Inj Insulin (Human) Cartridges Plain Inj Insulin Aspart Inj Isolyte –P, 500ml Inj Levofloxacin 500mg IV inj Lignocaine 1% inj Lignocaine 2%, 30ML inj Lignocaine 4% inj Lignocaine with Adrenaline Inj Magnisium Sulphate, 2ml Inj. Mennitol IP 10g + Glycrein 10g per 100ml bottle Inj.Meropenam, 250mg, 1gm Inj. Metclopramide 2ml Inj. Inj. Methyl Prednisolone Sodium Succinate 1gm Inj. Methylcobalamine 500ug, IV & IM use, No preservative or stabiliser Inj MVI 10 ml, Inj Nor adrenaline, 2ml Inj Normal Saline 0.9 %, 2 Lit (Plastic Inj Oxytocin, 1ml Inj PAM, 500mg/2ml Inj Paracetamol Inj Parentral Fat emulsion 10% (500ml), 20%(250/500ml), Inj Pentoprazole 40 mg/ ml Inj Phenytoin Sodium, Inj Piperacilin, 4gm + Tazobactum,500mg, Ala Inj Potassium cloride 10ml Inj Propofol 1%, 20ml Inj Prostidin 125mg/ml Inj Rabeprazole 20mg I/V Inj Ranitidine, 2ml Inj Ringer Lactate Inj Saline, 3% Inj Sodabicarbonate 7.5%, 25ml Inj Sodium Bicarbonate-7.5% Isotonic, 10ml Inj Sodium Chloride, 10ml Inj Somatostatin, 3mg/1ml Inj Tetanus Toxoid 0.5ml amp/5ml vial Inj Tramadol, 2ml, Inj Vancomycin 500 mg Inj. Vecuroniun 4mg/2ml 11 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 Inj.Meropenem 500 mg , 1 gm & 250 mg Inj.Nimodipine Inj. Octreotide 50 mcg & 100 mcg Inj. Amoxycillin 1 gm + clavulanic acid .2 gm Inj. Noradrenaline Bitartarate I.P. 400/2m Inj. Iron sucrose injection USP 20 mg/ml 5ml Inj. Verapamil 2.5 mg/ml Inj. Freeze dried acyclovir I.V. infusion 250 mg/vial Inj Vitamin A (1 lac units per 2ml) Inj Vitamin D (6 lac units per 1ml) Inj Vitamin K 1 Jelly Lignocaine Hydrochloride, 2% Liquid Paraffin + Milk of Magnesia (200ml), Liquid Potassium Chloride IP 1.5 gm, (corresponding of elemental Potassium) in a flavoured, Sugarless base per 15ml, 200ml Bottle Lotion Betamethasone 0.05% + Salicylic Acid 2% - 50ml bottle Lotion Clotrimazole 1%, Beclomethason Dipropionate 0.025% w/v, Propylene Glycol, I.P. 15ml Lotion Gamma Benzine Hex achloride 1%, 100ml Mouth Wash - Chlorhexadine Gluconate 0.2% w/v + Sodium Floride 0.05% w/v + Zinc Chloride 0.09% w/v, 150ml bottle Multivitamin drops - Drops each ml contains : Vitamin A Concentrate (Oily form) IP, (As Palmitate) 2500 IV, Cholecalciferol IP 200 IU, Ascorbic Acid IP 25mg, Thiamine Hydrocholride UP 0.5mg Riboflavine Sodium Phosphate IP Equiv, to Riboflavine 0.5mg, Nicotainamide IP 5mg, Pyrdoxine Hydroxide IP 0.5mg, D-Panthenol IP 1.5 mg, VitmainE Acetate IP 2.5mg. Natural Compound Medical Dressing Solution 50ml Oint Benzoic Acid 12% + Salicyacid 6% + Hydrocortisone Acetate 0.5% w/w 15gms Oint Betamethasone + Salicylic acid, 20gm, Besa-6 Oint Povidone Iodine, 15gm, 500gm Gel. Diclofenac Diethylamine B.P 1.16% w/w equivalent to diclofenac sodium B.P 1% w/v. Capsaicin USP 0.025% w/w. Methyl salicylate IP 10% w/w. menthol IP 5% w/w. 30 GM TUBE. Powder Clotrimazole, 75gm Rotacap- Beclomethasone 50, 100ug Rotacap-Budesonite100ug, 200ug. Solution 6% Hydroxy Ethyl Starch (130/0.04) with molecular weight 130,000 daltons; degree of substitution, 0.4 in isotonic sodium chloride Solution Gention violet 1% 100ml pack Solution Budesonide for nebulizer Solution Cetrimide 15 %, Chlorhexidine 7.5% 1 liter packs, Solution Formaldehyde, 5ltr, Solution Ipatronium for nebulizer Solution salbutamol for nebulizer, 15ml, Syp Cetrizine 5mg/5ml, 30ml, Syp. Zinc Acetate-50ml/100ml Syp Cyproheptadine HCL 2mg + B1 2.5mg + B12 2.5mg + B6 0.75mg + DPanthenol 2.5mg + Neacinamide 22.5mg/5ml - 200ml bottle Syp Dextrometharphan 5mg + Ammonium Cloride 60gm + Chlorpheniramine Maleate, 2.5mg + Gualphenesin 50mg (100ml bottle) Syp Digoxin Syp Enzyme (each 15ml containing) - Diastase (1:50) 60mg + L-Lysine Mono HCL 90mg + Vit.B1 3mg + Vit.B6 1.5mg + Vit.B12 5mcg + D-Panthenot 5mg + Niacinamide 24mg – Syrup base 200ml bottle Syp Erythromycin 125mg/5ml - 30bottle Syp Glycerol, 500ml Syp Iron (each 5ml containing) - Colloidal Iron, equivalent to elemental Iron 250mg + Folic Acid, 500mc g + B12 5mcg - 200ml bottle Syp Iron : Ferric AmmoCitrate 160mg + Vit.B 125mcg + Folic Acid 1mg + Zinc 12 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 Sulphate 40mg Syp Multi Vitamin Each 5ml Contains: Vita-A-2500I.U.+ Cholecalciferol 200I.U. + Vita E -7.5 I.U. + Thiamine Hck-2mg+ Riboflavin-2.5mg + Pyrudixube Hcl-1.0mg +Vita. B12- 1Mcg+ Vita. B3-22.5mg + Asorbic Acid – 40mg + Zinc Sulphate1mg + Potassium Iodide- 50mcg + ch Syp Ibruprofen 100mg + Paracetamol162.5mg each 5 ml Promethazine 5mg + Paracetamol 125mg each 5 ml Syp Paracetamol, 60ml Drop. Dicyclomine Hcl 10m + Simethicone 40mg /10 ml Tab. Atorvastatin 20mg Tab Amiodarone, 200mg. Tab Amlodopine 5mg + Atenolol 50mg Tab. Pantaprazole Sodium 40mg Tab. Pantaprazole Sodium 40mg+ Domperide 10mg Cap. Omprazole 20mg + Domperidone 10mg Cap Amoxicillin 250mg/500mg Tab. Fluconazole 150mg Tab Amoxicillin + Clavulanic acid, 1 gm per tab Tab Amoxy+Clavulanic Acid, 625mg, (per tab Tab B. Complex - Thiamine Mono Nitrate Ip 10mg, Pyridoxin Hydro Chloride Ip 3 Mg, Cynocobalamine Ip 15 Mcg, Riboflavin Ip 5 Mg, Nicotinamide Ip 50mg., Calcium Pantothenate IP. 5mg. Tab Calcium Carbonate Tab. Progesterone 400 mg (vaginal/rectal pessaries) Tab Cefuroxime Axetil, 250mg/500mg, (per tab Tab Ciprofloxacine, 250mg/500mg Tab Diclofenac Potassium 50mg + Paracetamol 500mg + Chlorzoxazone 250mg Tab Diclofenac Sodium SR-75,100 mg. Tab. Cefphodoxime Profetil 50mg/100mg/200mg Tab. Cefurxime Axetil 125mg Tab. Leofloxacin Hemihydrate 500mg Tab. Doxyphyline 400mg ER Tab Ethamsylate 250mg/500mg Tab Ferrous sulphate (equav to 60mg of elemental iron) Tab Gabapentin 400mg Tab Gliclazide 80mg + Metformin 500mg Tab Glipizide (sustained released) Tab Ibuprofen 400mg Tab Iron containing - Ferrous Furmorate 152 mg, Zinc Sulphate 61.8mg, Folic Acid 75mg Tab Iron Folic Acid (ferrous sulphate exsiccated IP 333-335mg (equiv.to100mg of elemental iron)+folic acid IP 0.5mg Tab Methylcobalamine 500 ug , 1500 ug Tab Ofloxacillin 200mg + Tinidazole 400mg Tab Paracetamol 500mg Tab Rabeprazole 20mg,40mg Tab Ramipril 5 mg. Tab Ranitidine, 150mg Tab Spirolactone + Frusemide (50mg + 20mg) Tab. Loratadine 10mg Tab. Levocetrizine 5mg Tab vilda gliptin 50 mg (anti Diabitic) Urine Alkalinizer containing Disodium Hydrogen Citrate 1.38 – 1.55gm/5ml100ml Bottle, 13 Tender Group No. II List of items for General Surgical Consumables S.No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Name of Item Abdominal Sponge, hydrophilic non-woven,3layer,Lycra Pipin Bounded with radio opaque marker & long string size: 30cm X 30cm, 20 X 20cm Reusable)ETO Sterile Abdominal drainage set , sizes 22,24,26,28,30 Aerosol Mask Transparent Mask With Nose Clip, Feathered Edges With Star Lumen Tube Alcohol Based disinfectant with 50 g 1-propanol, .075 g Didec yldimethylammonium Chloride per 100 grams solution (in tissue & spray form) Alcohol swabs Anaesthetic Kit consisting of OT Half Gown-1pc, Face Mask-1pc, Cap-1pc, Spinal Drape-1pc (all non-woven spunlace, impervious & breathable fabric), Hydrophilic lint free Swab-5pc, ETO Sterile Bandages - Cotton Roll (10cm X 5mtr) (Dzn) Bandages - Cotton Roll (15cm X 5mtr) (Dzn Black Breaded Silk Suture 2.0 Silk Roll (box of 06) Closed Wound Suction Unit (ADULT) ( 12,14,16G Complete Mask With Tubing For Nebulizer Disposable Disposable Surgeon Gown (small, medium, large) [Water repellant, breathable, splash res istant surgeon's gown Abdominal Swab With Radio Opaque Thread (30x30cm 8 Ply) Adhesive Plaster, 7.5 cms x 5mtr (per spool Band Aid (WaterProof) Black Breaded Silk Suture 1.0 Silk Roll (box of 06) Blood Transfusion set Coated Polyglactin 910 (Rapid) Episiotomy Suture with double needle ½ circle round bodied, ½ circle, reverse c utting, 36mm 140cm (size: 2/0) (box of 12) Corrugated Sheet Plastic/Silicon Cord Clamp Disposable Sterile, Pyrogen Free Cotton Crepe Bandage (10 cm x 4m) Cotton Crepe Bandage (15cm x 4m) Cotton Wool Roll (500 Gms) Disposable draw sheet Disposable Nebuliser Chamber Different Sizes Disposable Sterile Syringes (single use) 50/60ml E.T. Tube Holder (Adult/neonatal), latex free with two part system which includes soft cushioned neckband with tube channel and adhesive backed base with velcro strip that adheres to neckband Elastic Self Adhesive Bandage (10cm X 4mtr) Elastic Self Adhesive Bandage (6cm X 4mtr) Elbow length procedure gloves for Labour Room, flexible, size - 6, 6.5, 7 General Surgery Drape non-woven spunlace, impervious & breathable with medical grade Opsite, size: 140cm X 300cm(sheet) & 18cm X 45cm(Opsite), ETO Sterile High Point Extension Tube Spirally Coiled With Male, Female Leur Lock In 100cm,150cm With Volume < 1ml High Risk Prevention Kit for Patient consisting of Bed Sheet-1pc, Pillow Cover1pc, Patient Gown- 1pc, Plain Drape-2pc, General Surgery Drape-1pc (all made of non-woven spunlace, impervious & breathable fabric), ETO Sterile High Risk Prevention Kit for Surgeon consisting of OT Gown-1pc, Hood Cap1pc, Face Mask-1pc, Leg Cover-1pair (all made of non-woven spunlace, impervious & breathable fabric), Surgeon Gloves-1pair, Eye Protection Glasses-1pc, ETO Sterile Hydrogel dressings for Bed Sores Sizes:- 6x12 cms,10x12 CM,12x24 CM, Dis c 14 Remarks 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 of 5cm & 6.5 cm Diameter. Oval Dressing size;- 5.5X 11 CM. Incision drape, Sterile, disposable Karman Cannula For Endomaterial Aspiration, 6,7,8,10,12 With Adaptor ECG Jelly Folley's Catheter Size 14 & 16, 2 Way Folley's Catheter Size 14 & 16, 3 Way Gauze Than (90 Cmsx18 Meters) Gloves Powder - Absorbable Glycerin Enema Hourly Urine Measurement Bag (Adult/Paed) I.V. Cannula Size 16, 18,20,22 With Integrated 3 Way Stop Cock I.V. Cannula Size 24 With Integrated 3 Way Stop Cock I.V.Set (Non-vent) Infant (Nasogastric) Feeding Tube Size: 5-10 Mack-In-Tosh (per meter) Micropore Surgical Tape Non woven viscose rayon porous backing with acrylate, Hypoallergenic adhesive. (Size - 1",2",3" x 10 yards) Mini vac suction drain - Size 8,10,12fr Non-Absorbable Silk Suture On Round Body 1/2 Circle Needle (No.1-0 to No.40) Non-Absorbable silk Suture With Cutting Needle 3/8 Circle (No.1-0 to No.4-0) Normal Delivery Kit consisting of Lithotomy Sheet with Leggings & Garbage Collection Funnel attached-1pc, PHMB antibacterial processed Dripping Sheet made of highly absorbent, lint free, hydrophilic non-woven-1pc, Gynae Pads highly absorbent, hydrophilic non-woven-5pc, Plain Drape-1pc, Cord Clamp-2pc, ETO Sterile O.T.Wear Kit for Prevention of HIV (Sterile) - wrap around gown of air permeable and Impervious Material, Face mask 03 layered, Cap, Leg cover and Goggles. Polyglactin suture on round body 1/2 circle needle (No.1, 1-0 to 4-0) Polypropylene Monofilament on R.B. Needle ½ circle (No.1-0 to No.4-0) Silicon Folleys Catheter Size 8 To 24F Stilet for E.T.Tube Surgeon Caps Disposable (Size: Unisex) Surgeon Mask Disposable, Tripple Layered Thermometer Oral & Rectal, Digital Three Way Cannula Ultrasound Jelly Vacuum Suction Drainage Set Disposable 8,10,12,14 sizes Tourniquet Kelly's Pad Rubber Leg U drape O cut, Sterile, disposable Leg U drape U cut, Sterile, disposable LINT (POUCH OF 500 GRM.) Lithotomy Sheet LP Drape Disposable Sterile Malecot Catheter (size-12,14,16) Measured Volume Set (110ml) Measured Volume Set (150ml) Monopolar loop for total and sub total Hysterectomy Mucus Extractor Multi lumen IV extension tubes Neo born baby kit, PHMB antibacterial processed consisting of Baby Shirt, Baby Cap, Baby Napkin, Baby Mattress with PVC Lining, Wraparound & Mosquito net for face Neo-natal IV sponges, non-woven, highly absorbent, lint free hydrophilic material with strong medical grade adhesive & PHMB antibacterial processed to prevent microbial growth Nylon suture on cutting needle 3/8 circle (No.1-0 to No.3-0) OT Apron, upto k nee length, made of Impervious Rubberized Polyester material & Spun cotton, pipin bounded with strings & autocleavable OT Full Gown, Non-woven spunlace, Impervious & Breathable, universal fit, 15 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 stockinet at cuffends, double overlap, ETO Sterile OT Towel made of Lint free Spun Cotton( Cotton-70%, Viscous-30%) & Rubberized polyester impervious material ,Logo of the Hospital, autoclavable, Size: 27" X 34" Paraffin Gauge (Sterile) (pack of 20pcs) Plain Drape PE, medical grade odorless & clear PP, with adhesive on sides, size: 100cm X 100cm ,100cm X 150cm,120cm X 200cm , 120cm X 300cm ETO Sterile Presterilised sheets for draping during s urgery with a hole of 10" size 24"x12" & 36"x 24" Reusable Earthing Pad ,Capacitive, Non-Adhesive, Non-sticky, Akton polymer made compatible with any brand Shoe cover pair. Silicone Double Nasal Tube For Neonatal Ventilation Catheter Length 4 Cm Sofratulle dressing Sterile Specimen Containers (100ml, 250ml, 500ml, 1000ml) Sterile Surgical Dressing Pad Gamma Sterile 10x10cm & 20x10cm Sterile Transparent Wound Dressing (variable sizes) Surgical Hand Coutry pencil PTFE Swab, Highly absorbent, lint free, non-woven hydrophilic material size: 5cm X 5cm, 7.5cm X 7.5cm, ETO Sterile I.V. Canula Trocar Drain For Pleural Drainage Of New Born Pvt Xro Marking Every Cm. One Lateral Sys. Female Luer Lock Urine Collection Bag with botton outlet Urine Sample Collection Bottle Yankaur Suction Set Sterilized 2.5 Mtr Long tube With Connector To Fit In Any Suction Machine, Transparent Cromic Catget Suture size 2.0, 1.0, 1, needled half circle, ¼ circle Plain Cromic Catget Suture size 2.0, 1.0, 1, needled half circle, ¼ circle Cromic Catget Suture Nio.1 half circle trocar pointed Vicryl no. 1, 1.0, half circled, cutting and round body needle 16 Tender Group No. III DEPARTMENT OF LABORATORY2009-2010 (NON- CONSUMABLE) (CONSUMABLE OF EQUIPMENT, IF ANY MAY BE QUOTED SEPARATELY) NON CONSUMABLS – biochem 1 2 3 4 Semi automated biochemistry analyzer – 1) Compact microprocessor – controlled, general purpose bi-chromatic photometer system with at least six filters ranging from 340 nm to 700 nm, to read & calculate results of both end point & Kinetic colorimetric assays. 2) Temperature – 37oC – Peltier based temperature control. 3) Light source – tungsten Halogen lamp 4) Measurement modes – Absorbance, Concentration, turbidometry 5) Calculation modes – single standard, multistandard – linear & nonlinear, factor, kinetic 6) Input – Facility to attach external key board 7) Output – built in printer & facility to attach external dot matrix printer 8) Measurement range 0.00 to 2.50 absorbance units (A) 9) Measuring device: Facility to use both cuvettes and flow cells 10) Ability to generate patient work list, reports and quality control data for not less than two levels for 50 parameters or more. 11) Facility to transfer data via LIS 12) Store reagent performance data (blank absorbance), calibration curves, Levy- Jenning plots and not less than 1000 patient results 13) One spare flow cell, 12 cuvettes, two bulbs, and 10 printer paper rolls to be supplied along with equipment. 14) Compatible online UPS with battery back up of at least one hour 15) with separate computer and printer Cell counter 3 part – Hematology analyzer based on impedance principal having 18 parameters i.e. HGb,wbc count, 3 part differential, MCV,MCH,MCHC,HCT,RBC count, plt count, MPV, RDW-CV, SD, PDW, P-LCR with whole blood and capillary modes, sample rotator valve with separate channels for wbc and rbc counting with floating discriminators for each, clog removal with minimum through of 60 samples/hour with result on screen and printer reagents to be available in Indian rupees. The instrument should have aperture monitoring facility and also employ time and volume count for better results Cell counter 5 part – Five part differential heamatology analyzer based on flow cytometry principle, with parameters viz WBC, lympho# %, neutron # %, mono #/%, eosinophil #/%, baso #/%, RBC,HGB,HCT,MCV,MCH,MCHC,RDW-CV, REW-SD, PLT,MPV,PDW,PCT4, Reticulocyte count %, 2 histograms for RBC and PLT, 2 scattergrams for Basophils & differential scattergram Perfprmance parameter WBC Linearity range 1.00-99.99, plt linearity range 10-1000. Reasearch parameter includes 2 histograms for RBC and plt: tft touch screen with external laser printer. Binocular Microscope – binocular microscope iso 9002 approved, with four objectives on reverse nose piece, wide field eye pieces with foldable eye guards, 20 watt halogen bulb light at base with easy accessibility of bulb with input volt range 90 to 240, mechanical stage 150mm x 135 mm with 76 x 50 mm movement supported on ball bearing guideways, coaxial focusing with autofocus stop, with stage moving knobs at lower right side, xl model ACL 7000 Specifications 1. Instrument should have a flexible test menu with clotting, chromogenic and immunoassay capabilities 2. Instrument should have a centrifugal analysis principle 3. Should have a nephelometric (at 660nm) and absorbance (405nm) reading 4. Instrument should have a internal barcode reader for sample identification 17 Unit Unit Unit 5 5. Reagent volume for factor assays should be 40 microlitres 6. Instrument should have auto dilution for samples and calibrations 7. Instrument should have 2 probes for sample and reagent 8. Expression of results for PT should be in seconds, activity& ratio or INR 9. Precision in analyses should be < 1 %(cv-pt),<2% (cv-aptt) 10. Instrument should use primary blood tubes and sample cups. 11. Instrument should collect and compute 1100 consecutive light scatter readings per reaction for better precision Coagulation Analyzer with consumables: Specifications:1. Instrument should have a flexible test menu with clotting, chromogenic and immunoassay capabilities 2. Instrument should have a centrifugal analysis principle 3. Should have a nephelometric (at 660nm) and absorbance (405nm) reading 4. Instrument should have a internal barcode reader for sample identification 5. Reagent volume for factor assays should be 40 microlitres 6. Instrument should have auto dilution for samples and calibrations 7. Instrument should have 2 probes for sample and reagent 8. Expression of results for PT should be in seconds, activity& ratio or INR 9. Precision in analyses should be < 1 %(cv-pt),<2% (cv-aptt) 10. Instrument should use primary blood tubes and sample cups. 11. Instrument should collect and compute 1100 consecutive light scatter readings per reaction for better precision Unit 6 Slide warming table – Digital Slide Warming Table should be rectangular flattening table intended for clinical histopathology with a jet Black Aluminum Surface ensuring very high thermal conductivity rates & exceptional resistance to mechanical exploitations temperature ranging from ambient to 70° C can be Selcted. The programmed as well as set temp should be displayed on the instrument & set values memorized by a built-in battery backup system. The instrument should be modern. Top Plate Size : Length X Width 300 mm X 200mm The product should be CE Marked. Unit 7 VDRL rotator – Should be useful for VDRL & other agglutination tests, blood grouping test & for mixing of solutions in small flasks, beakers & bottles. Should be fitted with Timer. The rotator should have large platform size of 300 X 300 mm which should take concave slides, blood bottles & flasks held by spring holder. Should have a with Digital speed controller & Indicator as well as Digital Timer of 0 to 199 minutes to control the shaking duration. Should work on 220V single phase 50Hz AC supply.The product should be CE Marked. Slide staining container with slide holding rack (SS), Vertical for 30 pieces. SS Rack with SS container medium and large Blood vial rotator For uniform mixing of blood for better results on fixed and variable speed. Rocking and rolling motion, fully adjustable moving angle, speed 2-40rpm, for20 tubes Test Tube Holder Material-SS 18G/20G Sizes-Small/Medium/Large Needle burner and syringe destroyer Should destroy both i.e. needle and syringes in a safe, ecofriendly and cost effective manner. Should have provision for inserting the used needle to the small hole provided and the needle should be destroyed with in seconds. Specially designed electrodes should generate high temperature to instantly incinerate the needle. Should have provision for inserting the syringe on the top of the machine in the big 2ml hole provided with a cutting blade, just pulling the lever should cut the syringe into two . Should have tray is built in to collect needle residue & Syringe container to collect syringe bodies after cutting. Should be provided with battery backup with built in power source trickle charger. The Unit 8 9 10 11 18 unit unit unit Unit battery should constantly charge when the main is on. It should automatically shift to battery power in case of a power failure without disturbance in the operation. Should be fitted with an overload trip device. The product should be CE Marked. 12 13 14 15 16 17 18 Manual cell counter 8 units Physical weighing balance for laboratory for weighing chemicals 0-100 grams Centrifuge machine Should have a digital timer Body should be made of strong fabricated & corrosion resistant steel Control panel – for start/stop switch, dynamic brakes, step less speed regulator with zero start switch & speed indicator with timer and protective fuses. Door interlock Maintenance-free brushless drive motor with exact speed pre selection and digital display in control panel. Speed range 100 to 6000 rpm and above. Tube Holders as appropriate Shall meet IEC-60601-1-2:2001(Or Equivalent BIS) General Requirements of Safety for Electromagnetic Compatibility. The unit shall be capable of operating continuously in ambient temperature of 10 -40deg C and relative humidity of 15-90% The unit shall be capable of being stored continuously in ambient temperature of 0 -50deg C and relative humidity of 15-90% The supplier should be ISO certified for quality standards. Product should be FDA/CE or ISI approved Should comply with IEC/TR 61010-3-020 :Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-020: Conformity verification report for IEC 61010-2-020:1992 Particular requirements for laboratory centrifuges" Should comply with IEC 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – part 1: Microslide Cabinet - Horizontal Manner Should have a storage for atleast 10,000 slides .Should be useful for safe and easy handling of 75 X 25 mm slides. Construction should be of CRC sheet, well designed for its performance, durability and appearance. Should be powder coated paint outer finish with smooth working doors fitted with handle, lock and key. The anodized seamless moulded ( die- pressed) aluminum slide strays for holding 75 X 25 mm slides, should be arranged separately so as not to disturb other compartments while taking out or putting in the slides. The size of the tray should be 335 X 230 X 35 mm and should be properly fitted with uniformly slotted aluminum carries in four rows, each holding 50 slides i.e. each tray should hold 100/200 slides in horizontal position and should be fitted with index holder. Slider holding slotted rows should be numbered 1 to 50 to identify the slides. The manufacturer should be ISO & WHO-GMP certified. The product should be CE Marked. unit unit UPS battery 12V, Dry Battery Pharmaceutical Refrigerator Capacity ( i) 330 Ltrs Specifications Should have drawers/ shelves Should have cross flow blowers Should have fully automatic temperature controls. Should not be effected by ambient changes Insulation should be not less than 55mm in any case Door should essentially be solid door. Should have a 365 days temperature & humidity recorder paperless Should be supplied with Voltage stabilizer Lab refrigerator 720 lts Unit .unit 19 unit unit unit 19 20 21 22 23 Specifications Should have drawers/ shelves Should have cross flow blowers Should have fully automatic temperature controls. Should not be effected by ambient changes Insulation should be not less than 55mm in any case Door should essentially be solid door. Should have a 365 days temperature & humidity recorder paperless Should be supplied with Voltage stabilizer Centrifuge Machine – Heavy duty with digital timer, speed setting, capacity 36 tubes Water Bath Digital Should be ISI Mark Should provide exceptional temperature control of liquid for uniform and stable temperature. The inner chamber of the Water Bath should be made of seamless corrosion resistant stainless steel grade 304 for a longer life time and easy cleaning & External Material should be M.S Sheet, Power Coated. Excellent temperature uniformity should be obtained by incorporated PID control system which maintains the temperature very precisely. The system should have a high wattage heater to act in response to any settled temperature more quickly compared to other systems, but only a fraction of the heater wattage should be consumed when the set temperature has been achieved, saving lot of energy. Should have in built soft start for heaters to prolong the heater life. Should have auto key lock feature to ensures no manipulation could be done within the system while being operated by an un-authorized person. The unit should incorporate user friendly feather touch buttons for setting temperature, delay time and process time which should be visible on seven segment display. LEDs should indicate the mode of operation. All the process date should be recorded to remote computer via RS232/RS485. Also should have an attachment for the printer. Should have remote monitoring alarms & controls. Should have Data Retentive Delay and Process Timer to ensure that the material inside is objected to the set temperature for the set time only, irrespective of any power cuts or voltage fluctuations. Temperature Range should be Ambient-80°C, Temperature Sensor should be RTD (PT 1 00). Control System- PID, Programmable Microprocessor, Temperature Set & Display Sensitivity should be O. l°C. Temperature Fluctuation should not exceed +0.l°C. Timer - 999 Min delay +999 Process, Should work on 230v,50 Hz. AC. Internal Dimensions: WXHXD 330 x 300 x 150 mm for 4packs The product should be CE Marked. Cytospin Cytocentrifuge Low speed centrifugal force to separate &deposit on slides, cyofunnel load on tilted position to prevent cell loss. Programmable acceleration speeds 200-2000 rpm capacity for spinning 4- 12 samples simultaneously. Autofixation mode & improved lid mechanism FNAC syringe holder Incubator . unit unit LIST OF CONSUMABLE ITEMS RATES TO BE QUOTED IN AS PER OUR PACK SIZE ONLY AS AND WHERE MENTIONED. NO OTHER RATES OF DIFFERENT PACK SIZE WILL BE ACCEPTED AT ANY CONDITION 1. Biochemistry Kits 20 a. Uric acid enzymatic end point, single reagent in stable liquid form kit with standard 125ml b. Creatinine kinetic test kit jaffe fixed time test with stable reagent in liquid form with standard 200ml c. Urea kinetic GLDH method kit with reagent in stable liquid form with standard 200ml d. Total bilirubin kit D.M.S.O. method single reagent for total bilirubin with separate sodium nitrite solution without need of sample blank with each test with standard 2x250ml e. Direct bilirubin D.M.S.O. method single reagent kit with separate sodium nitrite solution without need of sample blank with each test with standard Serum glutamate oxaloacetae transaminase test kit IFCC/MDH/NADH kinetic single step with stable reagent in liquid form 2x250ml g. Serum glutamate pyruvate transaminase test kit IFCC/LDH/NADH kinetic single step with stable reagent in liquid form 250ml h. Alkaline phosphatase kinetic reagent kit IFCC/PNPP method, single step, stable reagent in liquid form 250ml i. Protein biuret reagent kit end point with standard 2x50 ml j. Albumin bromocresol green reagent kit end point with standard 2 x 50ml k. Glucose reagent in lypholized form GOD/POD end point with standard 10 x 100ml l. Total cholesterol reagent enzymatic/POD end point single stable reagent in liquid form with standard and calibrater 250ml m. Hdl cholesterol third generation direct homogeneous method based on selective solublizing effect by use of special surfactants having two reagents ready to use liquid stable till expiry with standard and calibrater 160ml n. Ldl cholesterol third generation direct homogeneous method based on innovative surfactant technology with ready to use two liquid stable reagents stable till expiry with standard and calibrater 160ml o. Triglyceride test kit lipase/glycerol KIN/GPO/PEROX. End point single step stable reagent in liquid form with standard 250ml p. Calcium kit arsenazo III end point, single reagent in liquid form stable at room temperature with one to two min incubation with standard. Phosphorous kit with molybadate UV end point stable reagent in stable liquid form kit with standard Lactate Dehydrogenase enzyme kinetic kit DGKC single step reagent in stable liquid form kit Serum amylase kit in stable liquid fom , CNP –G3 method kinetic kit Liquid assayed multi quality control human serum based chemistry controls in three levels, 3 year shelf life at -20 degrees, 30 days unopened stability at 2 – 8 degree centigrade, 14 day open vial stability at 2 – 8 degree c, all three levels For electrolyte analyzer – rapid chem. by Siemens Rapid chem.. Reagent (trouble shooting kit) Daily cleaning solution Reagent kit Urine Diluent Sample cups Pump tubing Electrodes Controls for electrolyte analyzer. – trilevel standard company 3x50ml f. q. r. s. 02. 03. a. b. c. d. e. f. g. 4. 21 250ml 1x125ml 30ml 8x1ml 12x5 50ml 50ml Unit 500ml Unit Unit Unit 10x3ml 5. Strips for Glucometer – accucheck 6. 7 8. a. b. c. d. e. f. 9. a. Controls strips for glucometer Distill water (double distillation) For cell counter – H3D Premier by Diagnova RFCL - Hematon plus – Diluent - Hemaref II - Rinsing solution - Cell lyse - Lysing agent - Hemaclean - Cleaning solution - Probe cleanser - E-Z cleanser For ESR analyzer - med India ESR analyzer Citrated tubes for ESR – (evacuated/ non evacuated) ESR tubes for med India ESR analysis, Monitor J, EDTA/Non-EDTA sample compatible tubes Disposable droppers 2ml, 3ml,5 ml For electronic hemoglobin meter – hemocontrol by Diamed Strips for hemoglobin meter Drabkins reagent Hemoglobin pipette Cuvettes Capillary tubes for CT 12” size RBC pipette WBC pipette Liquichek haematology 16 control with 6 month shelf life trilevel for haematology analyser b. 10. a. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. New improved neubauers counting chamber Glass Beaker Borosil Make 10ml, 250ml, 500ml, 1000ml. each Cover slip big 22 x 50 mm of optically flat english glass no 1 Cover slip 22 x 22 mm of optically flat English glass no 1 Whatmann filter paper circular 10 cm diameter Filter paper sheet of fine quality, whatmann type 75x 46 cm size Glass marking pen (OHP marker pens)– Black, Blue, Red Glass Rods Glass test tubes with rim 12 x 75mm, (Borosilicate Glass Heat Resistant) Glass test tubes without rim, 12x100mm (Borosilicate Glass Heat Resistant) Holder for Vacutainer syringes Immersion oil for microscopy Lens cleaning Solution Pasture Pipette (disposable) Printing paper for analyzers (57mm, 100mm) Stickers white 20 x 15 mm (SDDMSC printed, bar-coded with date for lab reporting) Stickers white 50x 20 mm printed SDDMSC 35. Stickers white 50x 20 mm printed SDDMSC 36. 37. 38. 39. 40. 41. 42. Test Tube Rack, Aluminium 96 holes, 46 holes Disposable tips 5-200/ (Yellow) Disposable tips 200-1000/ (Blue) ml blueDisposable tips 5-20 Tooth Picks Tourniquet Sterile evacuated blood collection tube (plastic) with powdered sodium fluoride for Blood sugar [EDTA+fluoride) tube size 13X75mm with 2 ml draw volume Sterile evacuated blood collection tube (plastic) with K3 EDTA (Silicon Coated) [K3 EDTA 7.5%] spry dried for hematology – tube size 13X75mm with 3 ml draw volume Sterile evacuated blood collection tube (plastic) with 3.2% buffered sodium citrate for coagulation tube size 13X75mm with 2.7ml draw volume 43. 44. 22 50tests/ bottle --5 liter 20l 20l 1000ml 17ml 100ml Unit Unit Unit 1000ml Unit Unit 100/pack Unit Unit 6 x3 ml Unit 10 gm 10 gm 100 no.. Rim 500 Unit Unit Unit Unit Unit 100ml 100ml Unit Each roll 30x75x12 100 per sheet 100 per sheet Unit Unit Unit Unit Box Unit Unit Unit Unit 45. 46. 47. 48. 49. 50. 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 Sterile evacuated blood collection tube (plastic) with acrylic gel & clot activator for serum chemistry determination – tube size 13x75, 13x100 with (3,5,7ml draw volumes Sterile evacuated blood collection tube (plastic) plain with clot activator for serum chemistry determination – tube size 13x75, 13x100 with (3,5,7ml draw volumes Vaccutainer needle Vaccutainer system for pediatric blood collection Unit Vaccutainers Needle Holders Serum separator vial Attached hinged cap, 2 ml capacity with sticker, air tight Permanent marker thick tipped Lancets with pen device and disposable lancet unit Unit Unit Unit Unit each Unit 1 Pen with1000 Lancet Pack of 100 Unit each Tissue paper – good quality Tissue roll – good quality Measuring cylinder borocil make of class A quality certificate – 1000ml, 500ml, 250ml, 100ml and 10 ml Each Conical flask – borosil make of class A quality certificate for stain preparation –100ml, 500 ml, 1000ml Each Slides – deluxe size 25x75mm , 1.45mm thick, polished edges, lint free packing, with frosted end one side for labeling Toniquet (rubber, Velcro) Autopippets - 1000µl,100µl, 200µl.(single channel, fixed), variable volume – 10100microl, 100-1000micro lt. Prothrombin time test kit reagent in stable liquid form along with CaCl2 (0.25 MOL%) solution Partial thromboplastin time with kaolin reagent in stable liquid form along with CaCl2 (0.25 MOL%) solution Stopwatch Rack for tips Rack for pipettes Microcuvette for Hb & Hematocrit with 10ul of capillary, venous or arterial blood for haemoglobinometer Rubber Tubing- Tourniquet Blood Grouping Tiles- sp - Blood grouping tiles (1. One set 2. reusable) - Transparent with individual slot steps Urine Container (Plastic) Slides deluxe size 25 x 75 mm,1.45 mm thick,polished edges & lint free packing made from optically flat glass,delux model 4 Blood Grouping Tiles- 1. One set 2. Reusable 3. Transparent with individual slot steps blood grouping kit pasture pipette (glass) Each 50slides/box Unit Unit 12x5 ml 12x5ml Unit Unit Unit 50 test Unit Unit Unit 50 slide /box . unit 10x3 ml unit SEROLOGY 72 73 74 75 76 77 78 79 80 81 82 Typhi RAPID,IgG /IgM RPR card test for syphilis TPHA test for syphilis Hbsag rapid card test (sens 1ng/ml) with positive control in each card Approved for blood bank use by drug controller CRP slide test with controls with sensitivity of 6 mg% Rheumatoid arthritis Factor latex kit with controls ANA Profile (LIA) with 15 antigens Pregnancy card sensitive as low as 25iu/ml with in built control, store at room temperature. Result as early as 1 min. 100% specificity ASO latex kit with positive and negative controls and sensitivity 200 units/liter Procalcitonin Q Widal slide test kit coloured antigen for salmonella typhi O,H & Salmonella 23 unit unit Unit unit 50 test 50 tests unit 50 Tests 25T 5 ml x 4 83 84 85 86 87 88 89 90 91 92 93 94 paratyphi AH, BH HCV rapid card / spot to detect antigen con ns3, ns4, ns5 (4 th generation) test kit with positive control incorporated in each card approved for blood bank use by drug controller Rubella IgG & IgM rapid test TORCH Profile (LIA 16T/kit) Filariasis kit leshminiasis detection kits Rapid meningitis combo kit with positive and negative controls Rapid Immunochromatographic Test for Malaria with Antigen capture assay of P. Falciparum and P.VIVEX Strip to test albumin and sugar in urine Ketodiasticks for testing glucose and ketone bodies in urine Multistix to test for sp.gr, ph, glu, prot, bil, urobil, ketone, blood, nitrite in urine Lugols iodine Strips for detecting occult blood in stool basd on benzidine and H2o2 reaction UNIT 50 tests 50 tests 30 tests 50 Test 100 strip 50 strip 100 strip 25 strip/ box CYTOLOGY 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 Koplin jar Horizontal lid glass. Koplin jar Vertical lid glass. Koplin jar, Vertical With lid portable Slide staining jar with ground glass lid for 30 pieces Ethyl alcohol AR Methanol AR Formaldehyde 40%AR DPX mountant Leishmans stain Lieshmans powder with solution Xylene AR sulphur free Brilliant cresyl blue for reticulocyte count Brilliant cresyl blue powder Sodium citrate Sodium citrate powder Sodium chloride powder (pure grade) Dibasic sodium phosphate anhydrous Monobasic sodium phosphate anhydrous Geimsa stain Giemsa powder Eosine Methylene blue 98% sulphuric acid Haematoxyline EA 50 OG-6 1% Acitic Acid Sulphosalicylic acid Sulphur poweder Benedicts reagent Light green Gills hematoxyline Harris hematoxyline Fields stain A Fields stain B Rapid PAP stain kit Hydrochloric acid Sperm seperation kit Cryo prep-1 kit Cryo wash kit Sperm wash media 24 Unit Unit Unit unit 500ml 500ml 500ml 250ml 500ml 500ml 2.5 l 125ml 100mg 500ml 100mg 500g 100g 50 g 500ml 25g 25g 125ml 500ml 5g 100ml 125ml 125ml 125ml 100g 500ml 100 ml unit 125ml 25test/kit 10test/kit 10test/kit 136 a) b) c) d) e) f) g) h) i) j) k) l) m) n) o) p) q) r) s) t) 137 138 a) b) c) d) e) 139 a) b) c) 140 141 AIA- 360 by TOSOH FT3 FT4 T3 T4 TSH LH FSH AFP CEA BHCG CA125 Eastrogen Prolactin Progesterone Diluent Wash solution Substrate Standard cups Ethanol Sample cups Controls- trilevel standard company – human serum assayed immunoassay and TDM control Nephlometer – Turbox plus by Trivitron ASO CRP AT-III RA sample cups For semen analyzer - SQA IIC-P Disposable capillary Paper roll Capillary compartment cleaning kit (solution with cleaning capillaries) Wintrobes tubes for ESR test tubes (small) 7x75 mm size 25 20tests/kit 20tests/kit 20tests/kit 20tests/kit 20tests/kit 20tests/kit 20tests/kit 20tests/kit 20tests/kit 20tests/kit 20tests/kit 20tests/kit 20tests/kit 20tests/kit 4x100ml 4x100ml 2x100ml unit 500ml 20tests/kit 12x5ml 50tests/kit 50tests/kit 50tests/kit 50tests/kit Unit 50/pack unit unit unit unit Tender Group No. IV List of Items for Stationery, Lines & General Items S.No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 Name of Item Alkaline Battery Cell (all sizes including AAA) Baby Sheet waterproof. Bed Pan (Steel) Bio medical waste segregation System With three compartment -Black,Yellow and Red Bio medical waste segregation System with Two compartment -Black,Yellow and Red Bleaching powder 1 kg pac k, preferably ISI Marked Bucket plastic with cover – 25 Ltr Carbolic Soap Chemical treatment System (double bucket) for disinfection Coloured Poly bags for segregation and transportation of B.M. Waste – Red, yellow, black of sizes: (18”x 18”) Coloured Poly bags for segregation and transportation of B.M. Waste – Red, yellow, black of sizes: (24"X24") Coloured Poly bags for segregation and transportation of B.M. Waste – Red, yellow, black of sizes: (36"X36") Dinner Set (Bone China) Disposable Apron Plastic Disposable Glass Thermocol, 250ml Disposable Spoon Dustbin foot operate (Plastic) – Small (10Ltr) Dusters 24” x 24” Electricity Extension Board with power point (15 amp.), with 15-20 feet wire (wooden) ,heavy duty Electronic Platform model weighing Machine (iron made) for use in Bio Medical Waste with sliding ramp on 4 sides for trolley. With printer Foot Rest (LLDPE Material) 12" (L) x 18"(B) x 9" (H), tapper to front 3", Front height 6", Light weight, Unbreakable, Washable, Rust free, Maintenance free, durable material Glass Tumbler 200 ml Wall Clock (branded) Weighing Machine (Ordinary) Heat Convector ISI marked 2000 watts with thermostat Hot case ISI Medium size Hot Plate: - Rectangular top covered with stainless steel sheet 25 x40 x 14[10’’x16’’x6’’] fitted with on/off switch, energy regulator Liquid Soap per ltr. Lock size (Brass) 7 Lever Brass (50mm, 60mm, 70mm) Multipurpose trolley –ss material with four wheel (4”) drive with HDPE pot and HDPE lid with five colour Natural, red, yellow, blue, black. Naphthalene balls white 500gm pack ISI Marked. (Per k g) Oil Heater , ISI Marked O.T. sleeper V-shape and Front Covered , sizes 6, 7, 8 & 9 Odonil air freshness 100gm Paper Napkins 12” x 12” Plastic Jug with lid 2.5 Ltr. Plastic Mug 1 Ltr Road side Bins (Rate quoted should include installation of Bins at specified points) Room freshener(DIFFERENT FLAVOURS) Rubber Mat (Foot Mat) (size- small, medium & large) Scissors (cloth cutting) Sealing Wax (Pkt of 10 sticks) Set of 6 cups & plates (OFFICER) Soap case with cover Table Glass 4 mm, margin smooth & round per sq ft. 26 Remarks 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 Tape Measure 150 cm Tea Set (ORDINARY) Three pin plug 5 amps & 15amps (ISI Mark ) Tissue paper Roll Torch (2 Cells) ISI plastic (pointed white Light) Torch Cell ISI leak proof (Size - Pencil, Medium & Large) UPS with battery 1 KV with automatic control, with 1 hour back Urine Pot (Male/Female) Washing Powder (1 kg pack) Waste paper Basket (Plastic) Water Jugs, all sizes Emergency Light (isi) Hand Dryer (Double Blower) Fly Trapper(25”L*12”H*4” 2Tube ,2 Fit Each HT Transformer Good Quality Of PVC Cabinet)(isi) Stand For Kipping Equipment (48”*36”*12” Square MS Tube Pipe Powder Coating 1.5”*1.5”) Wheeled Bins (Round and Square Shape) ROOM HEATER (electronics) { voltage 230vs, frequency 50hz, power 2000 watt, , remote control , swing function automatic vanetimer, Safety cutoff,wall hanging,isi mark) Loading Trolley, Capable to take the weight up to 500KG, Steel Benches for patients, powder coated, three seater Disposables cans for sharp blaster sterilization unit Disposables inserts for sharp blaster sterilization unit Refrigerator (5star rating,branded,) LCD TV (32”,42”) Water Dispenser R.O. System (12to25ltr,isi) Floor Cleaning machine (light weight,isi) Air Curtains Should be Stainless Steel Body High velocity Ultrasonic Pest Repellers Should have high frequency ultrasonic sound waves between 20-25 khz approx. The should not inaudiable to the humans. Pallet Mobile Storage System Work bench Should made from M.S. powederd coated. Should be flexible system. Galvanished platforms with a platform load capacity of 100kg approx The benchtop surface should be smoothed. Linen Items 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 Abdominal sheets all cotton 48”x 72” Baby sheet all cotton 36”x 36” Bed sheet, SDDMSC weaved along the length both s ides SIZE 90 inches x 60 inches (approx) Blanket( patient )woolen Curtain cloth for general use cotton width 54” Curtain cloth superior for officer’s room width 54” Doctor’s blanket woolen Draw sheet all cotton 36”x 60” Gynae sheets all cotton 36”x 54”with central hole of dis ered sizes Ladies maxi stitched all cotton Leggings all cotton Pair O.T. Gown all cotton O.T. Towel all cotton 36”x 36” Patient Gown all cotton Patient’s kurta pyagama cotton Petticoat and jacket for female patient all cotton 27 91 92 93 94 95 96 Surgeon’s shirt and pajama (Green and colored) fine cotton Three fold screen curtains set 54”x54”- 1Pair Three fold screen curtains set 54”x 52”- 2Pair Towel large 54”x 27” Towel medium 48”x 24” Towel small 24”x 16” White coat full sleeve terricot White coat half sleeve terricot Stationery Items 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 All Pin Cushion All Pins Attendance Register Ball Pen(Blue/Red/Green) Board Pin(Classic) Calculator (10 Digits desktop, Dual Power with memory function, big digits with review facility for 100 and correction facility Carbon Paper (Black/Blue) all sizes Cartage for HP Laser Jet P 1505 Cartage for HP Ink Jet 860 Cartage for Toshiba Photocopier E-Studio 352 Cartage for SAMSUNG Fax SF-560-R CDs- Plain /rewritable Cello Tape size ½ Inches & 1 inch Dairy Register Dak Pad Date Stamp Dispatch Register Duplicator paper Envelop (File s ize) Brown Plastic coated. Eraser / Rubber File board File covers (name of the hospital and other particulars as desired printed on the c over) File wrapper Flags (self adhesive), size 1" wide & 3" wide Gel Pen (Blue/Red/Green) Glue Stick, 15gms GPF Pass Book Gum bottle 700ml big High Lighter Pen Ink for stamp pad Marker Pen Note sheet (best quality) Numbering Machine Paper Tray Paper weight Pen Stand- (2 pens) Pencil HB Pen Drive ( 2&4GB) Peon Book Permanent Marker Branded Photocopy paper (size-A4) 75GSM & ISI. Photocopy paper (size- A3) 75GSM & ISI. Photocopy paper (size- FS) 75GSM & ISI Pilot Pin (Blue/Red/Green) Plain register (2 Qr) Plain register (4 Qr) Plain register (6 Qr) Plain register (8 Qr) Plastic file folder 28 141 142 143 144 145 146 147 148 149 150 151 152 153 154 Punching Machine-single Punching Machine-double Short Hand Book Scale (12”) Stamp Pad (Small) Stapler (Big) Stapler (Small) Stapler pin (Big) Stapler pin (Small) Stock Register Suan (Pointed punch) Tags Cotton (bundal) Typing Paper U Clip White envelop (4” X 6”) per 1000 White envelop (4” X 9”), per 100 White envelop ( A-4) per 1000 White fluid with diluter Writing pad 29 Tender Group No. V Anesthesia & Critical Care S.No. 1. 2. (CONSUMABLE OF EQUIPMENT, IF ANY MAY BE QUOTED SEPARATELY) Name of Equipment Specifications MULTIPARA MONITOR Should have following specifications ; High Resolution TFT display Size should be 7 to 8 inches Built in rechargeable battery User friendly operational window 60 seconds full disclosure of ECG playpack Digital SpO2 even for low perfusion states Protection against artifacts Wireless communication with central monitoring system Isolation against defibrillation defect 5 lead ECG ,Resp., Digital SpO2,NIBP,Temp. Light Weight approx. 4Kgs. DEFIBRILLATOR Should have following specifications 3. O.T. & ICU MONITOR 4. DESKTOP PULSE OXIMETER The unit should be portable easy to use lightweight. Weight of the machine should not exceeding 5 kg. The unit should be based on biphasic technology up to 360 J. The unit should have both synchronous/Asynchronous mode. The unit should have both adult and pediatric paddies. The charging time should be less than 6 sec up to 200 J. The unit should have facility to display six lead ECG with heart rate alarm limit is from 30-300 bpm. The unit should have inbuilt thermal printer with a sweep speed of 25/50 shocks on battery or 2 Hours of monitoring. It should have integrated high resolution 5” LCD monitor for display of 6 lead ECG. It should have data storage for internal ECG & voice recording for at least 48 Hrs which can be later reviewed on a computer. The unit should be supplied with complete a accessories i.e ECG cable user’s manual and 5 packet of ECG Electrodes. Should have ; High Resolution TFT display & size should be 10.4 inches and 15 inches 5 lead ECG waveform display ST analysis, arrhythmia analysis Digital SpO2 even for low perfusion cases Network capacity to connect with CNS 72 hour tabular and graphic trend and data storage Standard parameters :ECG, Resp.,NIBP,EtCO2.IBP,SpO2,Temp. Upgradability for thermal recorder ,multigas {CO2,O2,N2O,5AA} and Cardiac output Should be; Portable Large 240 multiplied by 64 graphical display Good viewing angle Mains/battery operated 24 hrs. trends 30 Comprehensive alarms Should have these specifications Minimum of Windows XP based system Online monitoring of all parameters Online arrhythmia detection &ST alarm without data loss 96 hrs. trend for all parameters (graphical & tabular) Data transmission upto 30 meters Individual bed / patient information zoom facility Individual bed alarm priority setup with alarm lag report Easy printing option with any Windows XP compatible printer 4/8/12/16 bed alignment with different screen configuration Arrhythmia analysis and recall facility Selection of waveform display 5. MULTIPARAMETER WIRELESS CENTRAL STATION FOR ICU 6. MULTIPLE SYRINGE INFUSION SYSTEM Specifications should be Multiple infusion system for high flow rate upto 1200 ml/hr and a minimum of 0.1ml/hr Automatic syringe identification(10/20/50 ml for all major Indian brands of syringes) Mains and battery operable. Pressure alarm settings should be available Inbuilt drug library. Volume & time controlled infusion Flow rate controlled infusion function Total intravenous anaesthesia infusion mode for all anaesthesia drugs Patient controlled analgesia infusion Bolus rate upto 800ml/hr for 50/60 ml syringe Audible and visual alarm for syringe disengaged ,empty syringe, occlusion etc. 7. SYRINGE INFUSION PUMP 8. VOLUMETRIC INFUSION PUMP 9. BLOOD WARMERS Should have following specifications; Fully microprocessor controlled which surveys all operating and alarm parameters Automatic syringe identification (10/20/50 ml for all major Indian brands) Inbuilt drug library Flow rate selectable for 20 ml- max. 400 ml/hr. and for 50/60 ml- max. of 600ml/hr. Bolus upto 999 ml/hr for 50/60 ml syringe User friendly single knob operation Mains cum battery operation LCD Display Infusion should be programmed in rate(ml/hr.) or time(secs.) Audiovisual alarm indication for syringe disengagement, drive disengagement, empty syringe, occlusion) Should have Flow setting 1-1000 ml per hour Dose calculation feature Alarms for error with LED light & buzzer Having battery backup and status of battery charge Should have keep vein open feature at low speed Peristatic pump method Purge facility i.e rapid flow volume Alarm for bubble, tube clog, Door open, flow error , low voltage Power supply 220-240 volts It should have microprocessor control. 31 10. BIPAP MACHINE 11. OPERATION THEATRE TABLE 12 Fluid Warming System 13. OXYGEN CONCENTRATORS Dry heat rapid warmer Large bright LED display for easy view from distance Low and high temperature alarms with auto shut off at 400 Temperature setting should be from 370 C to 410 C in steps of 0.50 C. It should have mounting clamp for vertical and horizontal operations Multiple temperature censors It should have warmer sleeve from exit of warmer to patient Accessories Extension set approx 45 Centimeter with or without air bubbles tracks with two lver lock connectors Reusable silicon temperature insulation tubing It should be CE certified. Should have; Bi Level Spontaneous mode of operation I-PAP and EPAP IPAP: 4 cm H20 to 25 cm H2O EPAP: 4 cm H2O to 25 cm H2O Starting Ramp Pressure 4 cm H2O to EPAP level Ramp Time 0 to 45 minutes (5-minute increments) It should have reusable pollen filters, LCD keypad Should be provided with inbuilt humidifier should be CE certified Should have following specifications ; Table Top UP-Down movement Lateral tilt -200 Both Sides Kidney section up -150mm Trendelenberg position 300 Reverse Trendelenberg Position- 200 Back Section refraction- 80-up/15 down With standard accessories Anesthesia screen-1 Shoulder Support 2 Lateral Supports -2 Arm Rest -1 Kneee Crutches -2 Arm Board Radiolucent Top-1 Remote Control Handswith-1 1. It should provide sufficient space for infusion bottles of 500/1000 ml. It should have capacity of 18-32 bottles. 2. It should have warmth insulation having energy saving qualities and temperature stability. 3. The drawers dimension should approx 23 x 42x 28 cm. 4. It should have two drawers of dimension each. 5. Electronic and mechanical devices to prevent overheating. 6. It should have key switch for system test . 7. plastic laminated insulation plates, transport handle, four castors with wheel brakes 8. Drawers should have Metal extension, automatic closing, alarm signal when the door is open Should have following; Dimensions 27.5 in.Hx 16.5 in. W x 14.5in. D 24.5 kg weight ALARMS - Power failure, high and low pressure, 32 14. OXYGEN PRESSURE REGULATOR 15. 16. ULTRASONIC NEBULISER PATIENT WARMING SYSTEM 17. DIGITAL THERMOMETER 18. PHARMACEUTICAL REFRIGERATOR 19. OPERATION THEATRE SCRUB STATION temperature, battery test, low purity test(with optical oxygen monitor) PERFORMANCE – LPM Concentration 1-3 95%±3% 4 92%±3% 5 90%±3% Should be based on atmospheric pressure of 101 kPa at 70ºF(21ºC) Should be CE Certified Should be; 2 STAGE with FLOWMETER and FLOW RATE For B type and D type cylinders Heavy duty and should come with stand /trolley The system consisting of following specifications: Intended for use in pre operative, peri operative and post operative care in OT,. Recovery rooms ,ICU and wards. It should have multiple independent working temperature sensors on all heating elements Large temperature and alarm LEDs to view from distance. High temperature alarm with auto shut-off at 42 degree Centigrade Detection and display of errors and alarms in case of malfunction Preset temperature at 37 degree for neonates and 39 degree for paed. Which can be changed Compatible with Matress or Blankets. All mattresses to be equipped with pressure relief foam. Blankets made of soft, light weight and flexible textiles to cover patient body. Facility to warm 2 patients with one Monitor. Should be having both Celsius and Fahrenheit scales Auto switch off facility Washable Suitable for oral as well as axillary measurement ( i) 330 Ltrs (ii) 465 Ltrs. Should have drawers/ shelves Should have cross flow blowers Should have fully automatic temperature controls. Should not be effected by ambient changes Insulation should be not less than 55mm in any case Door should essentially be solid door. Should have a 365 days temperature & humidity recorder paperless Should be supplied with Voltage stabiliser. It should be fabricated from heavy gauge preferably type 304 SS, seamlessly welded and polished to a satin finish, designed to be installed on a wall using mounting carriers with removable front access panel for access to the water control valves, waste connection, stops and strainers., sloping bottom surface to minimize splashing and a tail piece with flat strainer drain, infrared sensor with built in adjustment for Hands free operation along with elbow action & knee action taps. thermostatically mixing valve control for constant water temperature. It should have user definable settings for different time periods. It is provided with soap dispensers and canceled hanger 33 20. ECG PLUS AED DEFIBRILLATOR 21. PATIENT TRANSFER TROLLY (Hydraulic) 22. AUTOMATIC SHOE COVER DISPENSER 23. AUTOMATIC SHOE COVER REMOVER brackets. Should have 3 Channel ECG machine with LCD Display 12 lead resting ECG with interpretation and thrombolysis software With integrated biphasic defibrillator technology Light weight upto 3 Kg and supplied with 10 lead ECG cable facility to enter patient data Should be an AED mode Unit should be made of epoxy poweder coated M.S. and should have the overall size 210 L x 74 Wcm Siderail up- 120 L x 37 H cm,. Positioning should be Backrest- 0 to 90 degree (dual air spring), Knee Gatch- 0 to 40 degree (crank), Height adjustment range- 35 cm (hydraulic pump), Trend./Reverse Trendburg, (e) Foot Position Lever- 0 to 15 degree (manual),side rail should be foldable with safety lock, Chest Xray platform,e. 5th wheel , Folding driving handle x 2PCs Name card holder x 1PC, h. Reverse oxygen holder x 1PC, Restraint strap loop x 5PCs/side CasteI(J central braking and steering system with head and foot pedal and Mattress should be at least 40 density, Hospital grade radiolucent mattress, constructed of flame retardant material with antimicrobial agents. And Covered with material resistant to blood, urine and chemical stains a. Dimension: (a) Overall – 210 L x 74 Wcm (b) Sleeping surface – 190 L x 64 Wcm (c) Siderail up- 120 L x 37 Hcm b. Positioning: (a) Backrest- 0 to 90 degree (dual air spring) (b) Knee Gatch- 0 to 40 degree (crank) (c) Height adjustment range- 35 cm (hydraulic pump) (d) Trend./Reverse Trend.- ±18 degree (hydraulic pump) (e) Foot Position Lever- 0 to 15 degree (manual) c. Side-rail:foldable with safety lock d. Chest X-ray platform e. 5th wheel f. Folding driving handle x 2PCs g. Name card holder x 1PC h. Reverse oxygen holder x 1PC i. Restraint strap loop x 5PCs/side j. Caster:8” central braking and steering system with head and foot pedal Automatic shoe cover Remover It should have digital display for the shoe covers The dimensions should be H - 70-80 cm W - 30-35cm L - 95-105cm Should have capacity to hold min. 100 covers Should be easy to operate Should be operable on 220V Empty weight should not be more than 35Kgs. Should not consume more than 50W of electricity 34 24. ADULT ACLS TORSO WITH INTERACTIVE ARRHYTHMIA SIMULATOR 25. GLUCOMETER Product should be CE marked ISO company will be given preference. Should allow wide range of ACLS training possibilities including arrhythmia recognition & confirmable defibrillation Should be supplied with storage case Should have palpable & visual landmarks Fully articulated head neck & jaw Realistic anatomy of the mouth ,tongue, oral pharynx, larynx,epiglottis,vocal cords,trchea,oesophagus Cricoids cartilage allows for practice of sellick manoeuvre Separate left & right lungs for auscultation Oral ,nasl,digital intubation facilities Suctioning capabilities Internal load box absorbs full strength of every shock Manual ,semi automatic, automatic defibrillation Monitor manikin like a real patient at 4 ECG sites & 2 defibrillation sites Compatible with all standard brands & types of defibrillators 26. OXYGEN CYLINDERS 27. 28. 30. NITROUS OXIDE CYLINDERS SPINDLE KEY FOR GAS CYLINDERS CYLINDER STAND WITH WHEELS FOR A and B TYPE and D TYPE CYLINDERS HAEMOGLOBINOMETER 31. AUTOCLAVE(HORIZONTAL) 29. Should be able to measure glucose from small drop of blood obtained by pricking the skin disposable test strip, which the meter reads and uses to calculate the blood glucose level. Test strip should be shelf life of at least 2 year The meter should display the level in mg/dl and mmol/l. A Type B Type D Type A Type should be made of good quality metal should be provided with antistatic wheels Should have capability to measure venous, arterial or capillary samples capability to measure all clinically relevant haemoglobin species and haematocrit. Measuring time should be less than 90 sec. should be fast and accurate Measure unit g/dl, or mmol/l (selectable) Reading error - 5% max calculation should be based on the principle of absorption photometry capacity to store at least 100 results with date and time should be battery operable in case of power failure light weight should be operable at room temperature samples should be able to taken in microcuvettes with store /shelf life of at least 2 years at the time of supply supplier should give undertaking of providing microcuvettes on short notice in case of shortage Should be ISI Mark Should be hydraulically tested to withstand 2.5 times the working pressure. Chamber, Jacket, Steam generator, outer cover should be made of 304 grade SS. Should be Triple walled with steam jacket and separate boiler Inner chamber and steam jacket should be of 35 32. ENDOTRACHEAL TUBE CUFF PRESSURE MONITOR 33. 34 Resuable LMA MANUAL SUCTION UNIT 35 HIGH VACCUUM SUCTION UNITS 36 BLOOD GAS ANALYSER Heavy gauge S.S. Sheet with leak proff argon-arc welding. Should have single piece door made of steel plate lined with S.S. from inside and back plate and ring should also made of thick stainless steel sheet. Door should have grooves to hold EPDM or silicon gasket to ensure leak proof locking. Door should have hinged self locking single piece thick steel plate lined with S.S. from inside door and should not open under pressure. Should have self locking automatically engaging devise with clutch mechanism to avoid opening of the door when chamber is pressurized. Sterlizer should be mounted on tubular steel frame duly powder coated with ground leveling screwed flanges. The Outer jacket should have insulation material & should be covered by steam polished stainless steel sheet. Steam generator should be made of heavy stainless steel sheet with minimum joints and bolted parts. Should be fitted with suitable capacity heating elements and low water level cutoff system, gauge glass assembly with shut off valves for water level indication, water inlet & outlet valves. Heater plate should have a hole for easy cleaning of the deposited scale. Should be fitted with pressure control device. Complete Sterilizer cycle should be controlled from one point with the help of multiport valve. Should have two speeds of steam exhaust. Drying of the sterilized load should also be done with the help of powerful ejectors. Switch Box should have main switch , pilot lamps, relays etc. and mounted on the stand of the sterilizer for easy operation. The sterilizer is provided with the triple safety features functioning independently & should back each other. A removable plug screen should be provided to prevent the discharge line from choking. Should have digital temperature controller with time that raises an alarm at a set time. Should have Automatic water feed system. Sterilizing Temp : 121 ºC Sterilizing Pressure : 1.2 to 1.5 kg/cm2(15 psi to 22psi) Power Requirement : Suitable to operate on 440Vvolts, 3 ph, 50 Hz, Ac Supply Should be ; Portable Light weight Calibration in mmHg (0 to 90)and cm of water(0to120) Should be re-useable silicon flexible laryngeal mask reinforced. Should be ; Manually operable with single hand Vacuum 450 mm Hg Having two containers of 250 ml with two different use catheters. - Housing should be made of Plastic Moulding (Rust Free). - Suction Capacity should be -700mm Hg+/-10 regulable, Flutter free vacuum control knob, have option of selecting 30Ltr/hr to 60Ltr/hr & vice-versa at the press of a button. - Twin Double diaphragm & lubrication free pump. Double overflow protection i.e; manual overflow device & electric shutoff on overflow. - Wide mouthed 2x2Ltrs PC Jars with self sealing bungs with overflow safety device. - Bourden type vacuum gauge 0 – 760mm Hg (also kg/cm2) Calibration. - Power 230V, 50 Hz +/-0.5 Amps, 430 watts. - Noise Level 50dB A+/-3 - C.E & ISI Approved. Should be 36 37 Air Purification System & Fumigation 38 WRIGHT’S PEAK FLOWMETER 39 BP APPARATUS 40 NEEDLE CUM SYRINGE DESTROYER 41 Percutaneous Neuromodulation Pain Therapy System Fully automatic,fast and microprocessor based/computer controlled of reputed brand. Should provide an all inclusive test menu offering at least the following parameters pO2,pCO2,Ph,H+,Hct,Hb, Na+,K+,Ca2+,Cl2+,Glucose,Lactate, standardHCO3,actual HCO3,BEecf,BEB,Anion gap, tCO2, O2 Sat,O2 Content , P50. Automatic calibration and washing. On screen display of results and in built Printer and memory. Results should be available in a maximum of 60 secs. Availability of separate bottles/bags for washing and calibration gas/solutions Should have economy mode with extended calibration interval to reduce the reagents consumption. Electrodes should have long life with guaranteed durability of at least three years each. guarantee certificate about the life of electrodes from the original manufacturer should be attached On board life,i.e stability of reagents after opening reagent bottle must be a minimum of 90 days. All the brochures /literature/catalogue must be provided by the supplier/firm to support the specifications claimed to be present in the equipment. UPS and CVT of required rating should be provided. Firm should ensure real time demonstration of the equipment put up for tender. – Air Purification System for killing Bacteria and fungus, for deodorize the air and stop regeneration of bacteria. – Should have user selectable program for fumigation and purification modes. – Should have four-stage mechanical filtration to trap 99.97% particles up to 0.3 microns. – Should have Activated carbon filter to remove odors and volatile organic compounds. – It should use ozone gas shock treatment for fumigation. The ozonation period should be user programmable with a provision for minimum 8 programs for 7 days in advance. – It should have maintenance of air purification by Ultra Violet Germicidal Irradiation technique at 254nm. – Should have High Efficiency Particulate Arrester Filter with its life monitor. – The machine should be programmable for 7 days and minimum 8 options /day. – The System should be wall mounted for maximum air purification. – The maximum area recommended for one should be 4000 cubic feet. – It should be manufactured by ISO,GMP and WHO certified company Should be 6 Inch dial Well mounted with extension tube Should be provided with cuffs of all sizes Equipment to destroy syringe & needle both in single action without use of battery or Electric Power. The cut hub & needle should fall in sharp containers made up of bio-degradable & Autoclavable material having minimum 2Ltrs Capacity. The equipment should 1. Should be be microprocessor based system capable of delivering output through 37 Percutaneous electrode Array ( 1.5’’ diameter microneedle array within 2.5” diameter hydrogel-based sterile electrode. 2. Should have signal output through two feed electrodes (Feed frequency 1: 3858 Hz, Feed Frequency 2: 3980 Hz) . 3. Should have voltage range : 0-27.5 V rms & waveform should be sum of 2 sinewaves. 4. Should have power source 12 V DC, 3850 mAh rechargeable NiMH internal battery. 5. Should have compatibility with following accessories 5a. Percutaneous electrode Array having 1000 microneedles 0.74 mm ( 1.5’’ diameter microneedle array within 2.5” diameter hydrogelbased sterile electrode. 5b. Surface feed electrodes of various sizes (2” x 4” and 5” x 8”). 42 ENDOTRACHEAL TUBE CUFF MANOMETER Hand pressure guage, for intra cuff pressure monitoring. Should be able to inflate or deflate cuff as per requirement and form an adequate seal and safe cuff pressure. Calibrated in cm h2o, fitted with clip attachment, for intra cuff pressure monitoring. Additional extension cord supplied with the instrument 43 REVOLVING STOOL 44 DRIP STAND 45. ANAESTHETIST CHAIR 46. KICK BUCKET 47. Foot STEP STOOL (Single and Double) ANATOMICAL FACE MASKS(RUBBER & SILICON) Should be Height adjustable 41 to 56cms. Stainless steel top with pneumatic height adjustment Moulded five pronged mobile base with 5cms. Swivel twin castors Should be Height Adjustable 136 to 240 cms. Stainless steel outer tube Stainless steel pole with 4 hooks Moulded five pronged mobile base with 5 cms swivel twin castors Should be Height adjustable 43 to 58 cms. Cushioned seat & back with pneumatic height adjustment Moulded five pronged mobile base with 5 cms. Swivel twin castors Provided with a foot ring Should have Three swivel castors Stainless steel frame Deep container All round bumper Should have Power epoxy finish with aluminium treads for grip 48. 49. 50. RINDAL BAKER SAUCHEK MASKS PAEDIATRIC LARYNGOSCOPE (Paeds & Adult) Sizes 0 to 5 Should be reprocessable and air cushioned type Optional- scented silicon masks should be made of antistatic material Set containing: 1. Laryngoscope Blade laryngoscope blade(s) with specially designed view tube allowing vision of 42 degree from straight line of sight, two sizes of blades available, small mouth and standard mouth 38 integral oxygen supply tube allows extension of intubation time, easy link up to Endoscopic systems provided blade containing replaceable fibre-optic element, Replaceable fiber clip for easy cleaning. Stainless steel , fibre-optic blades that complies with Green System (ISO 7376(iii) compatible) handles blade that fits on to International standard ISO compatible handle, all contact points between blade and handle must be of stainless steel. Production batch number must appear on blade a. Optishape Stylet Re-usable stainless steel stylets, two sizes (pediatric & Adult) with patented ideal shape . b. Handle Xenon bulb with gold plated housing and contacts with light output in excess of 2,800 Lux. Must hear click when blade is engaged onto handle to protect against faulty placing of blade Handle components of electrical system must be manufactured from stainless steel to prevent corrosion Handle conform to international standard ISO 7376(iii) 51. 52 Fan Holder For Endotracheal Tube And Anaesthesia Circuit Anesthesia Trolley 53 AMBU BAG WITH RESERVOIR BAG 54 LARYNGEAL MASK AIRWAY CLASSIC 55 LARYNGEAL MASK AIRWAY PROSEAL 56 INTUBATING LARYNGEAL MASK AIRWAY Unit should have high density resin / ABS framework, slide out writing surface, Hard surface plastic table top. Drawers of different configuration 3” , 6” 9” etc. with lock for keeping different items. Should be 100% latex free Air intake valve with integrated oxygen reservoir bag 360º rotatable patient valve which can be easily assembled and disassembled Should be available in adult/paediatric /neonatal models Should be Reusable ,upto 40 times autoclavable Made of medical grade silicon Separate inflation line Should have aperture valves to prevent obstruction by epiglottis Should be available in sizes 1 / 1.5/ 2/2.5/ 3.0 /4 /5/ 6 Cuff deflator for all sizes should be supplied Should be Made from medical grade silicon Should be reusable ,autoclavable at 135ºC Built in bite block Shold be supplied with an introducer,insertion strap Gastric port shold be compatible with 14 G ryles tube Should be available in sizes 1.5 ,2 2.5 ,3,4,5, Should be supplied with cuff deflaters Should be Made from medical grade silicon Should be reusable ,autoclavable at 135ºC SHOLD BE SUPPLIED with a 15 mm connecter 39 Sizes 3,4,5 Should be supplied with silicon ,soft ,wire reinforced ,cuffed ETT of 7.0 ,7.5 8mm internal diameter Should have stabilization rod of 20 cm 57 EO STERILIZER Should be Automatic microprocessor controlled Should have LCD display of cycle process i.e temperature,pressure,relative humidity in %,current phase, set values with context to time Size should be at least 4 ft x 1 ft Horizontal stand alone unit constructed from high grade ss material with radial arm door locking unit Should be capable of operating with both 100% EO Cartridges and EO:CO2 cylinder Puncturing of the 100% EO cartridge should be automatic Should have in built steam generator for humidification. The system should have remote monitoring and controlling software. The software has to be installed in the computer provided by the manufacturer for the purpose. It should give visual printed records in following formats. 1 Graph 2 Summary 3 Detailed data Rates of accessories , including 100% EO catridge is to be quoted 58 MAGILL FORCEPS Should be made of S.S. 59 ISI Marked and should be made of SS. 60 DRUMS FOR AUTOCLAVE MADE OF STAINLESS STEEL BOTH BIG &SMALL SIZES FORMALIN CHAMBERS 61. MULTIUTILITY CART 62. SPHYGNOMANOMETER 63. INCUBATOR FOR BIOLOGIC INDICATORS 64. SEALING MACHINE 65. SYSTEM FOR THE TREATMENT Three Trays 20” X 8” X8” Should have rail mounted drawers,atleast 10 in no.,5 on each side with trashbin on one side Solid base small instrument case on other side Should have stainless steel cage on top for for placing drugs and IV rod Writing base provision Should have provision for electrical connections & inbuilt power station Should be shock proof & shock absorbing polyamide housing latex free &push button air release valve. Fine & precise air release rate adjustment Ultrafast on release Practically wear free Autoreader ,self calibrating,to read rapid attest BI with twelve incubation wells ,each well with a red green & yellow light For ease of interpretation of positive BI readout time should be 1 hr.,3hr., 4hrs. by a visual red light & an audible alarm Should be Basic sealer for packaging of medical products Rotary sealing machine in coated metal housing white varnish, without starting atomization for packaging transport Sealing speed should be 10 m /min, digital temp. control,230 V Using surface bonded long lasting non-leaching antimicrobial 40 OF VARIOUS SURFACES 66. FUMIGATION MACHINE 67. Anesthesia Machine treatment. Chemical for the system: Should have broad-spectrum microbicidal molecule. Should be non-volatile non migrating material with a unique surface modifying technology to impart safe & lasting antimicrobial activity to treated surfaces. Shouldn’t contain arsenic heavy metals or polychlorinated phenols. Multipurpose, heavy-duty portable fumigation machine capable of producing aerosols with particle size of less then 5 microns, for use in critical and semi critical areas of hospital. Body should be compact, durable, leak proof and made of stainless steel/heavy duty plastic. The blower head should be rust proof and deliver aerosols uniformly. Machine should be compatible with all disinfectant solutions containing sliver nitrate, hydrogen peroxide in usual concentration. Machine should be compatible with maximum ph range (both acid and alkali). The tank capacity should be 4-6 liters, with easy cleaning facility. The machine should operate on 220 +- 10 Volts, 50Hz, single phase, A.C supply commonly used in Indian conditions The discharge rate should not be less than 1 Liter/25 minutes. The tank capacity, discharge rate and timer on the machine should be so that the disinfectant should be able to disinfect 4000-5000 cubic feet in one cycle of 2 hours (max). The equipment should be of good quality and conform to national/international standards. Machine should be user friendly and have safety features Cable should be at least 5 meters in length, ISI marked. Company should be able to demonstrate and train users on proper usage of the fumigation machine in the user areas The company should ISO or equivalent certified. 1.The Unit should have for the following gases - Oxygen, Nitrous Oxide and Air, 1. Low Flow Rotameter for Oxygen, Nitrous Oxide & Air, 2. Mechanical Anti Hypoxic Device with audio visual alarm with Propotionating device for 3. oxygen and nitrous oxide (link system) 4. Audio visual alarm for Oxygen Failure, 5. On/Off Switch with Basal Flow, 6. Backlit Rotameter, 7. Nitrous cut off in case of oxygen failure. 8. Airway pressure monitoring with audiovisual alarms during ventilator use 9. Ventilator bellows with gradations of 100 cc onwards 10. Auxiliary oxygen outlet. 11. Emergency oxygen flush 12. Pipeline Inlets for Oxygen, Nitrous Oxide, and Air,(DISS Compatible) 13. Cylinder Yokes for Oxygen(2) and Nitrous(1) Oxide with pin index, 14. 2 Deep Spaced Drawers, 15. Integrated Circle Absorber with On/Off and Bag-Vent switches, 16. Oxygen Sensor port. 17. It should have common gas outlet ISO standard taper and suitable for Open, semi 18. it should have open and closed circuit system. 19. Patient safety blow off valve if pressure> 50 cm H2O 20. In built drug and instrument tray on front portion of the 41 machine for anaesthesia drug and instrument 21. it should have the facility to mount a minimum of two vaporizers. 22. it should be CE marked 68 Vaporizer 69 Examinations Hammers 1. It should have high precise vaporizers. It has scope of concentration regulation. 2. Calibration range 0 to 5%. It should have interlock mechanism to lock in series with other vaporizers. 3. Easy to turn dials for safety locks to prevent accidental turn on. 4. CE marked. Should be of good make and quality 70 106 Nylon filaments Should be of soft texture 71 O.T. Bottle Holder Should fit into any hand disinfectant bottle of standard quality 72 Hand Rub Dispenser pump should be compatible with all standard hand rub solution bottles 73 SWAB RACK /STAND 74 HUMIDIFIER FOR BIPAP Should made of S.S. Overall size approx 137 h x 76 w x 46 D cms Should have frame work of s.s. Tubes mounted on 10 cms dia castor. Should Have Eight Rows With Six Hooks In Each Row. Should have S.S. Tray fitted on bottom side Should be compatible with standard BIPAP machines & should function as inbuilt humidifier 75 Emergency First Kit with respiratory Care Equipment 42 LIST OF CONSUMABLES FOR DEPARTMENT OF ANAESTHESIA S.No. 1. 2. 3. 4 Name of Item Wooden disposable tongue depressor Disposable plastic apron Disposable Cap and Mask Face mask with anti fogging shield 5. 6. Antifog Safety goggles OT wear kit (HIV) 7. 8. 9. 10. 11. Antimicrobial hand cleaning lotion Antimicrobial skin cleanser IV cannula IV and CVP dressing Transparent dressing pads 12. Surgical Tape 13. 14. 15. IV Drip Set Three Way Stop Cock IV extension Tubing 16. 17. 18. Measured Volume Set Blood Transfusion Set ECG electrodes 19. 20. ECG Jelly Ryles Tube 21. 22. 23. 24. 25. 26. Suction Catheters Foley catheter Urobags Bains Circuits HME filter Patient Connectors 27. 28. Endotractal tube with suction canula Airway 29. 30. 31. Endotractal tube with Bite Blocks Dental Guard Nasal Oxygen Catheter Specifications should be good quality It should be Knee length Double, non-woven cloth Double, non-woven cloth, malleable, smooth, nasal clip, strips and adequate length Eye shield or goggles double layers double fold Single Doctor kit – should be made of water repellent spun less fabric containing Facemask 3 layers with filter Hood cap Long shoe cover up to knee Gloves double high quality with change of Colour after puncture Gown one with internal lining in front and the sleeves Eye shield or goggles double layers double fold Double, non-woven cloth, malleable, smooth, nasal clip, strips and adequate length Should be ISI marked Should be ISI marked Should be with injection port and wings. (all gauges) Should be transparent dressing tape. Should be transparent and absorbent dressing pads. Sizes – 5x7, 9x15, 9x25, 9x35, 9x10 Should be soft cloth surgical tape. It should be hypoallergic, latex free directional tear surgical tape with 0.5, 1, 2, 3, 4, 5 inches Should be presterilized. And ISO certified. Should be ISO certified. Should be with three way stop cock., high pressure resistant low volume spirally coiled 200cm and should be ISO certified. Should be 100 cc with 10 ml overflow and flow controller. Should be with filter chamber and ISO certified. Should be disposable and standard size with button preferably with loc system Bottle of 250 ml. Ryles tube with distal end coned with SS balls, 4 lateral eyes, radioopaque line all sizes. Should be thumb operable and ET tube compatible all sizes. Should be silicone / rubber, all sizes, perefrbly ISO certified. Should be disposable with sample port. Should be disposable with APL valve. Should be anti bacterial and anti viral. It should be straight/ angled/ Y-piece/ T-pieces. It should be 22 mm , male-male, male-female, male, female. Guedels It should be with bite block with color code size 000,00,0,1,2,3,4,5 Nasopharyngeal size should be 5,5,6,6.5,7 It should be straight, curved flared and curved flared prong. 43 32. Oxygen Masks 33. Venturi Valves 34. Aerosol therapy mask 35. T-Pieces 36. 37. Anti Fog Solution Trachlight Set 38. Endotracheal Tube 39. 40. 41. 42. HYPODERMIC NEEDLES Combitube Endotracheal tube fixers Intubating Stylets 43. 44. 45. 46. 47. Nebuliser kit Circle Breathing system Carbon Di Oxide Absorbants Breathing Tube extension Breathing System T- piece 48. 49. 50. Bains Breathing System Disposable Spinal Drape Spinal Needles 51. 52. Epidural catheter set CSE set 53. Epidural Catheter extension 54. Epidural Needle With Catheter Set 55. 56. 57. 58. 59. 60. Cricothyrotomy Sets Percutaneous Tracheostomy set Tracheostomy Set Central Venous lines Arterial Cannula Syringes 61 Needleless Syringes 62 63 Disposable Needles Urine pot 64 65 66 67 68 69 Bed Side Commode Bed Side chair Commoede Steam Inhalation kit Incentive spirometer kit Adult Diapers Endotracheal Intubation set Oxygen masks should be with nose clip and oxygen tube. It should be adult and paediatric sizes. It should be silicone made ranule valves and ranule mask kit , modular ranule valves, direct ventury valve mask kits, adult ventury kit and oxygen recovery kit. It should be modular with small, adult, paediatric with and without nose clip. It should be made of silicone and modular, preferably ISO certified. It should be of good quality, clear sight, single use. Trachlight set illuminating stylet. It should be in all sizes with separate handle and light wand It should be cuffed and non cuffed in all sizes including flexometallic. All sizes(27G to 16 G) It should be in all sizes. It should be made of silicone and ISO certified. It should be malleable sheathed intubating stylets in all sizes. It should be adult and paediatric. It should be made of silicone and ISO certified It should be of good quality and in shape of granules. It should be made of silicone and should be transparent It should be t-pieces breathing system in infant size. (Mapleson F) Bains breathing system with inner lumen leak tester. It should be disposable spinal drape. Quinckes o should be18,20, 22,23,24,25,26,27,28 G with or without introducer needle. Whitcare o should be 25,26 G It should be made of silicone and ISO certified should be of good quality and should comprise of epidural needle,spinal needle,epidural catheter,bacterial filter and loss of resistance syringe It should be made of silicone extension tube for infusion of drugs by epidural catheter. Epidural needle touhy 16,18 G with marks at 1 cm intervals and epidural catheter with appropriate markings It should be cuffed.with 7.5 cm length It is made of silicone and ISO certified It should be in all sizes and should be disposable. It should be double and triple lumen. It should be with radioopaque line. It should be disposable syringes with all sizes i.e. 10 ml, 20 ml, 50, 60 ml. It should be non venting needleless syringes for in line catheter use 1,3,5 CC It should be in all gauges It should be made of PVC with gradations showing urine volume. It should be made of PVC and leak proof. It should be made of PVC and should be leak proof It should be of good quality preferbl;y ISO certified It should be of good quality preferbl;y ISO certified. It should be of good quality preferbl;y ISO certified It should contain Endotracheal tube, stylet, laryngoscope blade, tube holder, suction catheter, suction tube, syringe 5ml, 10ml, and gloves 44 70 Spinal Set 71 Epidural Kit 72 Pressure infusion bags 73 Uristicks 74 75 76 77 BULBS FOR LARYNGOSCOPES,ADULT &PAEDIATRIC LONG LINE MADE OF POLYURETHANE MATERIAL FOR CVP MEASUREMENT DISINFECTANT FOR CLEARING THE SUCTION SYSTEM SURGICAL TAPE 78 SURGICAL TAPE (STRETCHABLE) 79 TRANSPARENT DRESSINGS 80 TEGADERM DRESSING WITH ABSORBENT PAD 81 DRESSING WITH SOFT CLOTH REINFORCEMENT 82 IOBAN INCISE DRAPE It should contain swabs, gloves, sheet, small towels, spinal needle, syringe 5 ml, 10 ml 20ml, Epidural puncture needle, liquid medicine filter, air filter, epidural aneathesia tube, plastic syringe, 5ml glass syringe, needleless syringes 3 nos., tube holders two, skin brushes, gloves, non woven fabric with hole, two gauze, dressing pad, tampon. 500 ml, 1000 ml, 3000 ml capacity Optically clear window like nylon netting for viewing infusion fluid level Tested to be free of pin holes Visible gauge to indicate bladder pressure It should be for protein, sugar and ketones. Should be 16 G length 70cms. Needle through needle technique Should be Phenol &aldehyde free Biodegradable 4.2 gm amidosulfonic acid 3.28gm Na Hydrogen Phosphate,Tensides,Audiliaries Sizes ½”,1”,2”,3” X 10 yards Woven fabric, acetate taffeta non elastic tape with strong tensile strength, bi directional tear-ability and high adhesive strength for securing critical tubings and devices Sizes should be 2”,3”,4”, 6”,8” × 10 yards Hydro entangled polyester fibre, non woven porous perforated thus breathable, water resistant, stretchable soft cloth backing, coated with pressure sensitive hypo-allergic acrylate adhesive. Should have following specifications Single sterile, transparent, semi-permeable, water and bacteria proof thin conformable polyurethane film; coated with water repellant hypoallergic pressure sensitive acrylate adhesive with unique paper window frame delivery design. Sizes 6cmx7cm ; 10cmx12cm ; 10cmx25cm; 15x20cm ; 20cmx30cm Should be ; Single sterile,transparent, semi-permeable,water and bacteria proof thin conformable polyurethane film; coated with water repellant acrylate hypoallergenic adhesive with paper window frame delivery and having a non adherent absorbent pad. Sizes - 5cmx7cm; 9cmx10cm; 9cmx15cm; 9cmx20cm; 9cmx25cm; 9cmx35cm Should be Single sterile,transparent, semi-permeable,water and bacteria proof thin conformable polyurethane film with one half laminated with soft cloth breathable backing for enhanced grip. Sizes – 5cmx5.7cm ; 8.5cmx10.5cm Incise drape comprised of polyester , thin breathable, low memory iodophor impregnated film offering gradual sustained relief for 7 hrs. Drape coated with pressure sensitive acrylate adhesive 45 83 SURGICAL CLIPPER 84 85 CARTRIDGE FOR SURGICAL CLIPPER SURGICAL DISPOSABLE GOWN 86 HAND DISINFECTANT 87 GLUTARALDEHYDE MONITOR 88 MULTIENZYME CLEANING SOLUTION AUTOCLAVE INDICATOR TAPE 89 90 ETHYLENE OXIDE INDICATOR TAPE 91 CHEMICAL INTEGRATORS-STEAM 92 BOWIE DICK TEST PACKS 93 RAPID READOUT BIOLOGICAL INDICATORS PATIENT PLATES 94 Surgical clipper with disposable blade assembly operated either by battery or cord.It should be having cutting blade position away from skin. Should be with unique modern ergonomic design. Should be Non woven 4 layered sterile,lightweight,breathable,low linting surgical disposable gown with outer & inner layer made of strong &spun bond repellant fabric and two middle layers offering fluid control and bacterial barrier. Sizes medium 132cms.,large 142cms.,xlarge 148 cms.,xxlarge 156cms. Should be Antiseptic alcoholic slution for hand hygiene containing 2 propanol &mecetronium ethosulphate with pleasant fragrance. The solution should be capable of killing micro organism including bacteria,spores, virus, fungi & algae Indicator strips should check minimum effective conc. (1.5%) of 2% glutareldehyde solution by a visual colour change readout within 2-3 mins. Must act against all possible body secretions compatible to instruments Should be Heat sensitive chemical indicator self adherent tape without leaving any adhesive residue for steam sterilization cycles Colour change should be from white to dark brown for easy identification after processed in steam autoclaves of different time & temp. requirements within 15 minutes at 121 degree C & 3 minutes at 134 degree C. Size 1/2×30 mtr. roll Should be Applicable to both warm & cool temperature cycles run at 37ºC or≥50ºC ¾”×55mtr. Roll Moving front chemical integrators should verify all parameters of steam sterilization together i.e. time ,temp.,& quality of steam Read out indicates accept or reject after processing allows to differentiate all the parameters Should be Test sheet along with penetration challenge material should be in single easy handled pack For steam and ETO sterilisation Should be Disposable grounding plates for electrosurgical use, with thin conformable, tear resistant, fluid resistant, fluid resistant, occlusive polypropylene backing coated with thick and soft hydrophilic conductive adhesive gel. Plate design to have handling tabs, plate lined with transparent polyester liner and available in split and non split versions with both cord and without cord design for adult and paediatric applications as a Universal size. 46 95 BASIC SURGICAL PACK Should be Made from absorbent impervious material Should contain all contents ideal for general surgery surgical procedures which includes hand towels table cover, operation tape & adhesive drape sheet Must be sterile Sterile leg covers for lithotomy position Should be ; Sterile adhesive strips of porous ,non woven, rayon backing,reinforced with polyester filaments for skin closure,coated with pressure sensitive ,hypoallergic acrylate adhesive Sizes 6mm×100mm,12mm×100mm,25mmx125mm Heat sealable sterilization packaging material of medical grade paper on one side & laminate of polyesters &polypropylene on the other for both steam & EO sterilization Packaging material has its chemical process indicators for both ETO &steam sterilization process printed on paper side to allow the differentiation between processed &unprocessed packages Should be available in 10 commonly used sizes should come in all adult sizes and should be of good quality should be of good quality contents should be provided in a good sized briefcase and should include all the equipments of emergency resuscitation including laryngoscopes with blades of all szes,airways (all sizes),intubating styllette, ambubag with mask - Aqua, alcohol denat, sodium laureth sulfate, Sodium Chloride, PEG-7, PEG-200, Glyceryl Hydrogenated , Palmitate , Glyceryl Cocate, Dibutyl Adipate, Sorbic Acid, Citric Acid. 96 97 LEGGINGS FOR LEG COVER SKIN CLOSURE SYSTEM 98 STERILISATION PACKAGING MATERIAL 99 Nasophyrangal Airway 100 101 DISPOSABLE SHOE COVER ADULT RESUSCITATION(CPR) KIT 102 Antimicrobial hand cleaning lotion 103 Intubating Stylette. Should be malleable with plastic sheath. Should have soft distal tip. Should be sterile. Should be available in sizes of 6fr---2.0mm,10fr--3.3mm & 14fr---4.6mm 104 Combitube The tube should have unique double lumen design for rapid establishment of an effective airway through either esophageal or tracheal placement There should be blind placement which eliminates the need of laryngoscope.. The tube should have pharyngeal balloon which inflates to hold device firmly in place and helps prevent the escape of gas through nose or mouth. The tube should have full length lumen which allows for suctioning of gastric content s with no interruption of patient ventilation should the tube airway be placed in the esophagus. Esophagus cuff inflates to seal the esophagus so that gas does not enter the stomach and gastric content are not aspirated . Should be available in two sizes of 37fr 7 41fr. Tube should have number of holes for better airway passage. 47 105 Closed suction system 106 Catheter mount 1. The catheter should be part of the breathingg system during suctioning without disconnecting ventilator support. 2. The catheter should be atraumatic, dual density & should have flexible, ultra soft , round distal tip . 3. The system should have rotating patient access valve to enable complete isolation of the sleeved suction catheter from patient airway when suctioning is not required. 4. The suction catheter should have all round depth marking in cms that allow easy measurement of proper catheter insertion in the trachea. 5. The catheter sleeves should have strength and transparency with tactile sensitivity and a metered dose inhaler for more effective, quick and convenient drug delivery. 6. The system should have an online closed port for bronchoscopy up to 5mm bronchoscope. 7. Should have thumb Controller to control extra pressure from suction machine. 8 Should have self sealing cap after bronchoscopy procedure is performed. Should be flexible, Should be having bronchoscopy port. Should be of good quality. 48 Tender Group No. VI Equipments for Medicine Department S.No. 1 Name of Item WASTE BINS 2 Alcolmeter (Breath Analyser) With Printer 3 Drug Dispensing System 4 5 Metallic ECG Trolley with Lockable Wheels. ICU Bed Mechanical 6 Ultra violet Room Sterilizer 7 Vital Sign Monitor 8 9 Patient Mobiliser Decontamination Cart Specifications It should be automatically open when hands will be near it It will automatically close after 6 seconds It should work on 6V Batteries only The outer body should be made of Stainless Steel & inner should be high quality ABS It should have capacity of 30 Ltrs. Also quote the price for Additional Inner Bin Separately. The equipment should be a portable one ,light weight and can be operated on battery as well as mains The equipment should be able to measure quantitatively the alcohol level in the expired air of an individual suspected to have consumed alcohol. The equipment should be able to give a printable record of the measured alcohol level with date & time. Should have Measuring range : 0.02 to 2 mg/liter BrAc The equipment’s Response Time – 30 to 35 second at room temp. Specificity – not to be affected by : a)acetone, b) Paint, c) Fumes from glue, food, confections or any other item found in human breath. The equipment should have LCD Display. The detection of alcohol should only be done with a Platinum electrochemical fuel cell at temp -5 to 40 deg C. Calibration- Automated either by dry gas or wet bath simulator. Memory function facility (with date & Time), even after switching off the instrument. Downloading Facility. Should be with all standard Accessories. Should have able to store atleast 400 ltrs of medicines Should have able in built revolving space saving drawers to keep variety of medicines Should have able lockable covers to prevent unauthorized access. Should be mechanically operated backrest, height and knee break. Should have parallel beam mattress platform. Should have removable head and foot boards. Should have tuck away side railings Able to came cardiac chair position. Should have integral telescopic IV Drip rod and urine bag hooks CE mark Should have able multilevel mechanical filtration, UV light, electrostatic precipitator (ESP), negative ion generator, Ozonation system and Hepa filter. Should have Bi directional connectivity to central monitoring system Non volatile Trend graph memory Design enables head rail mounting Should have 7 ECG leads Should have wave from freeze time selectable 30 Sec, 1 Min. 2 min 4 min Should have buzzer system Should have pacemaker detection & ST Analysis Should be upgradable up to 7 parameters. Should have roller based & easy to handle. Should have U.L.V fogger Should Have 3 tube U.V system Should have Air purification/ Humidifier / De humidifier system. Should be self powered too. 49 10 Patient record reterival system 11 Three channel ECG machine 12 ECG machine 12 channel 13 Ophthalmoscope 14 15 Oto Scope Spirometer Should be open to all & password operated specific storage in one with software as standard & compatible with all available formats. Hand band type. Band should be reusable. Shoulh not exceeded 2” x 3” inch to facilitate tying & carrage. It should have Automatic, Mannual and programmed recording modes 12 Lead simultaneous acquisition It has 3 channel and rytham lead recording facility, it has inbuilt high resolution thermal recorder It has alarm for different frault conditions, common error indicator , printer recorder error , beep sound of all keys. It has indications of ECG lead selected, cursor position, filter on/off, pacer detection and print error. Should have 12 channel simultaneous acquisition, LCD display having 320 x 240 dots, displaying both 3 and 6 channel with interpretation facility, inbuilt Thermal printer, capable of printing 3, 6 and 12 Channel simultaneously, internal rechargeable Ni-Cd batteries, 12 standard Leads, sensitivity of 5 mm/mV, 10 mm/mV, 20 mm/mV, 5 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s. Should have filters: Muscles tremors; Power line interferences. Should support more than 2 hours of continuous operation. Should conform to quality standards. 1. 2.5V/3.5V with aspherical optical system, having 74 single diopter steps having xenon Halogen Bulb, 2. Recessed coating window, 3. Dust proof, 4. Having 7 apertures with separate free filter, 5. Suitable for large or small pupils, 6. Incorporated slit apertures, 7. Fixation star, cobalt blue filter and red free filter for improvrd contrast. 8. Power source Rechargeable Battery/ Dry cell one. 9. Rates of Re chargeable battery should be quoted. \ flow range -15- 16 liters/ min, volume range 0-8 liters/ Back light LCD screen 16 17 PFT Machine with paper Echo Cardiography with Colour Doppler machine 3.1 Latest generation Electronic Phased array Color Doppler system with Minimum 512 Electronic independent channels. 3.2 256 gray shades for sharp contrast resolutions 3.3 Adult & Paediatric Trans thoracic Cardiac and Vascular Probes to be supplied which should be latest generation wide band transducers. 3.4 Harmonic Imaging- System should have following modes in 50 harmonic with separate setting for: a. Tissue Harmonic. b. Contrast Harmonic c. Harmonic Angio. d. Quantification of harmonics imaging 3.5 Harmonic imaging capability in Adult Cardiac, Pediatric Cardiac and linear Probe 3.6 Gain control in two dimensions for additional level of flexibility to image quality control. 3.7 Real time high frequency 2D for higher resolution and low frequency Doppler for higher sensitivity in all probes 3.8 Frame rate should be 300 FPS or more 3.9 Steerable PW/CW in all Phased Array probes. 3.10 High-definition acoustic zoom for enlarging sections of 2D and Color flow images with more acoustic information for greater clarity and detail while maintaining an optimal frame rate. 3.11 Modes – 3D, 2D, M-Mode, Steerable PW/CW Doppler, Color Doppler, and High Definition Color flow. 3.12 Monitor should be 15" or more, high-resolution color Monitor. Tilt and Swivel monitor should be able to view in all angles and all light conditions. 3.13 Color Flow Imaging for a) Increased lateral & spatial resolution. b) Detection of even subtle areas of turbulence, displaying a more physiological blood flow appearance without loss of frame rate. c) Color flow with capability of automatically picking up color flow as a function of focal depth 3.14 Tissue Colorization (B-Color) for improved contrast resolution 3.15 Application software for Adult, Pediatric, Fetal and Peripheral Vascular and Trans esophageal applications. (All application package should be built into the system) 3.16 Cine loop memory- more than 120MB of memory. a. High Frame rate review for better clarity of playback images study in slow motion. b. Quad loop with memory for pre and post image comparison of any procedure. c. Memory- 256 frames or more in quad loop. M Mode & Doppler Scroll Memory-40 seconds or more. d. Frame grabber facility for post analysis. 3.17 Various maps for pre and post processing. 3.18 ECG and respiration trigger facility. 3.19 User defined system and application presets for multi-user department. 3.20 Minimum 4.8 GB optical disc drive for image storage and retrieval. (Standard with system) 3.21 Dedicated integrated dynamic stress echo package for flexible user defined protocols with stacked sub loops facility and contrast stress protocol usable for stress echocardiography. 3.22 Tissue movement colorization with quantification possibility for IHD/CAD/Heart Failure patients. 51 18 19 20 Finger Pulse Oxymeter Sengstaken-Blakemore tube ECG Paper roll 21 22 23 ECG Paper Roll Surgical Tape Bone Marrow Biopsy Needle 24 Liver Biopsy Needle 25 26 27 Kidney Biopsy Needle Automatic Gum for biopsy Spinal Needle 28 29 Pleural biopsy needle AED 30 Trachostcomy tube 31 32 33 CVP Scale CVP Connector lines CVP catheter 34 Insulin Applicator 3.23 Three or more transducer ports. 3.24 Color Map resolution up to 128 levels. 3.25 Facility for high definition digital acquisition, review and editing of complete patient studies. 3.26 Facility of Real time perfusion studies 3.27 PC based Peripheral system comprising of dedicated computer at least 100 GB storage space (Hard disc) with 1 GB RAM or more with a Microprocessor speed of more than 3.00 GHz, frame grabber incorporated (All Software Inclusive) interfaced with the echocardiography machine with DVD writer and a high quality Color Laser printer. CD/DVD produced should be playable on any system. 3.28 Color M-Mode 4. C.E. certified ,measuring pulse and oxygen saturation Good quality Z Fold Orian Model (L & T) For Vega Model Machine Good Quality 1)Stainless steel with stellate and needle iliac crest Jamshidi 2) Stainless steel biopsy needle with guard and stellate sternal SALAH 1)Menghini Type 2)Liver Biopsy Gun 3) TRUCUT BIOBSY NEEDLE 4) Wilms Silverman needle Good quality Menghini Type Renal biopsy automatic Gun disposable 1) Stainless steel Sizes from 18-28 Gz disposable 3-4 inches Abrams pleural biopsy needle System should work on biphasic rectilinear wave form. System should have icon for complete chain of survival System should provide CPR help System should have pictorial and verbal help System should run on easily available consumer batteries. Disposable all sizes , cuffed , non cuffed Tracheostomy tube PVC with low pressure high volume cuff, adjustable flange 15 mm Connectors size5 ,6,7,7.5,8 &8.5 Good quality CVP Cathetor(Triple Lumen ) (Seldinger type) full set 7.5 Frwith dilator, needle (introducer) Guide wire ,2 syrings Ultrasonic Insulin applicator is a microprocessor controlled transdermal drug delivery devices using the ultrasonic technology which transdermal permeation of the insulin and other medium & Small molecular medication. It should the provide the diabetic Patients who administer insulin by mean of inj., sustained release of the insulin & eliminates the pain associated the drug Inj. Transdermal drug delivery eliminates the irritation to the digestive system via the oral & Gastrointestinal absorption. 52 35 Non-Invasive Bilirubin Analyzer 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 13. 14. 15. No Needles Required A Totally invasive insulin delivery system Direct Blood Stream absorption via on demand delivery system A Recharge able battery system is located with in device Should have POCT instrument for non-invasive measurement of total serum billirubin levels for neonates. Should have no pain, no trauma, no risk of infection and no hazardous waste Should be able to perform during and after phototherapy. Should be able to perform during age (24-42 weeks) and post-natal age (0-20 days). Measuring range should be between 0-20 mg/dl. Should have accuracy of + mg/dl & standard deviation (instrument to instrument repeatability) should not be more than + 0.66 mg/dl. Weight of instrument with battery pack should not be more than 356 gm. Instrument should have rechargeable battery of life minimum 1 year and measurement per full charge must not less than 100 test. Should have tungsten bulb as a light source for minimum life of 30,000 measurement. Should have FDA approval, CE marked certificate and published independent clinical studies. Accurate results in standard clinical units regardless of race or gestational age. No need to perform separate analysis or refer to conversion tables. Immediate, point-of-care result gives you the information your need, when your need it. Clinical care decisions for discharge or therapy are made more efficiently. Consumables of Non-Invasive Bilirubin Analyzer 1. 36 Fully Automated Biochemistry Alayzer for Critical Care Automatic calibration for each measurement with the consumables ensures accuracy without a baseline measurement. 2. Cost-effective, standard of care, and convenient management of newborn jaundice. The instrument should be dry chemistry system to perform chemistries, electrolytes and Blood gas tests. Should be light weight/portable and should also run with automobile battery. Should have a memory to store more than 1000 patients reports Test reporting time should be less than 15 minutes for any of the profiles/group of tests Should be use friendly and easy to operate even by nursing staff, paramedics etc. Should be able to test with very small amount of whole blood/Serum/Plasma. Should be CE Certified/FDA approved 53 Tender Group No. VII PEADIATRIC DEPTT (CONSUMABLES) S.No NAME OF THE ITEM 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. Hypodermic needles Syringes I.V. cannula I V. set Peadiatric drip set Blood infusion set Infant feeding tube Ryle’s tube Urinary catheter Urine bags Gloves Umbilical catheter Three way stop cock Infant Urine Collector Sterile Disposable Baby Nappy Oxygen mask Oxygen tubing IV Cannula Dressing Mucous extractor Umbilical clamps Baby identification tags Kidney biopsy needle Uristicks Central line Disposable plastic apron Disposable cap Disposable mask Disposable shoe cover Chlorhexidine hand wash bottles Alcohol swabs TECHNICAL SPECIFICATIONS It should cone in size 26-20. It should be disposable 1ml, 2ml, 5ml, 10ml, 20ml, 50 ml It should made of silicone and Size – 26-18 Good quality polythelene tubing with a stopper It should made of polythelene 100ml +- 10% chamber It should made of silicone and size should be 5-10 Different sizes Different sizes Small, medium size It should be sterile latex surgical gloves diff sizes Different sizes It should made of silicone with neo, pead size It should be sterile and disposable It should be single,sterile,transparent,water & bacteria proof.Size 5x5.7cm, 6x7cm. Good quality Non-breakable, good quality Different sizes Uristicks for glucose and albumin Different sizes Good quality Male/female 3 layers with nose clip Good quality 200ml, 500ml, 1000ml Packed individually, Should be wet Spacer with mask Different sizes Complete tray for It should have catheter, 3 way stop cock, 50ml syringe, 20 ml syringe, gloves exchange blood transfer and sterile sheet. CPAP tubing For bubbling CPAP Liver Biopsy needle Different sizes Wooden Spatula Pack of 500, 1000 Endotracheal tubes(cuffed) Cuffed endotracheal tubes, clear thermo sensitive material, radio opaque line, 15mm connector. Good quality and atraumatic hooded tip, allows easier insertion with cuff, in sizes 4.5, 5, 5.5, 6. Endotracheal tubes (plain) Plain endotracheal tubes, clear thermo sensitive material, radio opaque line, 15mm connector. Good quality and atraumatic hooded tip, allows easier insertion without cuff, in sizes 2.0,2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6. Bed Bath with Wet Towels Should made of Non woven spunlace fabric size should be 24 X 30 CMs approx Laminate structure- 12 micron poly + 40 micron LDPE with Aqua Baby Bed sheet with It should be made of non woven spunlace fabric of 40 gsm laminated with cushion 12 micron LDPE. 54 NON – CONSUMABLES CONSUMABLE OF EQUIPMENT, IF ANY MAY BE QUOTED SEPARATELY 1 Laryngoscope fibre optic (for Infants) Set containing1. Laryngoscope Blade laryngoscope blade with specially designed viewtube allowing vision of 46 degree from straight line of sight, integral oxygen supply tube allows extension of intubation time, easy link up to Endoscopic systems provided Stainless steel , fibre-optic blades that complies with Green System (ISO 7376(iii) compatible) handles blade that fits on to International standard ISO compatible handle, all contact points between blade and handle must be of stainless steel. Production batch number must appear on blade a. Optishape Stylets Re-usable stainless steel stylets, two sizes with patented ideal shape. b. Handle Rechargeable Handle Xenon bulb with light output in excess of 2,800 Lux. Must hear click when blade is engaged onto handle to protect against faulty placing of blade Handle components of electrical system must be manufactured from stainless steel to prevent corrosion Handle conform to international standard ISO 7376(iii) 2 3 Oxygen Hoods Ambu bags 4 Weighing machine 5 6 Weight and height measuring scale Vital Sign Monitor 7 8 Kidney Tray Nebuliser 9 10 Bed pans Digital thermometers 11 Suction machine electronic It should be made of polycarbonate with small, medium and large size Self-inflating silicon resuscitation bags with volume of 250-500ml.. Should have facilities to connect oxygen reservoir bag. Should have springloaded pop-off valve set to 35-40 cm water pressure Should be provided with non-rigid silicon facemasks of sizes – 0 and 1. Electronic baby weighing scale with flat baby tray which can be used for lying down and sitting babies with detachable baby pan. Unit should have 0-20 kg range and 5 gm resolution/accuracy through the range. It should work on AC as well as rechargeable battery. I t should be electronic with digital display and weight upto 180 kg or more and height upto 185 cm unit should be CE certified with BMI Vital sign monitor minimum 5 parameters: spO2, NIBP, temp., ECG, RR with facility for up gradation for invasive monitoring for CVP & intra arterial pressure with colored screen display size minimum 8" screen with battery backup of 90min., should be complete with all accessories. CE/FDA/TUV certified/approved. It should be made of SS and size small, medium large. Nebuliser Piston Compressor Heavy Duty with mouth piece, Adult mask,connector,5-filter It should be made of S.S with standard size It is having both Celsius and Fahrenheit scales Auto switch off facility • Washable Suitable for oral as well as axillary measurement Electrically Operated ISI marked, heavy duty motorized pump/1HP & ½ HP, 2 suction jars of 2 ltr. capacity each, suction capacity 25-35 ltr. Per minute, 55 12 Suction Machine foot operated 13 Billrubinometer 14 Glucometer 15 16 17 Infantometer Flux meter Non – Invasive Blood pressure Monitor 18 Breast feeding Pump 19 ABG machine pressure upto-700mm of mercury, cabinet with SS top and handle, 8-10mm dia non collapsible tubing, moveable on castors, overall size 40X30X65 cm. It should be small size, battery operated. It should be have max. negative pressure value 0.08 pa. Reservoir capacity should be 1000 ml and should be certified. Unit should have Liquid Crystal Display for easily view. Should be Streamlined designed and easy to be handled., low energy consumption. It should have Battery indicator. It should provide test results rapid providing serum bilirubin concentration. It should have Storage and memory function. It should be 7. Convenient to browse and delete functions. And should be certified. It is capable To Measure Glucose From small drop of blood obtained by pricking the skin. It has disposable test strip, which the meter reads and uses to calculate the blood glucose level. Test strip have a shelf life of 2year The meter displays the level in mg/dl and mmo1/l _._It should be made of polycarbonate and should be standard size Unit should be able to measure the intensity or the lux of fluroscene tube. Displays plethsmogram wave form, trend, battery status, time and Date. Read through motion and low perfusion conditions. It should have Audible and visual alarm for pulse rate B.P., system failure and low battery.Pulse rate from 25-250 bpm. With accuracy +-2 NIBP measure mode auto surge Working mode auto/ manual, For adult, Paed, Neonates. Alarm range for systolic, diastolic and mean pressure. Power 220V, 50 Hzs. Screen size 5.8” Wt. 1.5 Kg, Unit should have a cup to fit the breast to extract the milk in a bottle directly. The mouth of bottle should be computable with the nipple attachment so that the baby can be fed without touching and transferring the milk. It should work both on battery and AC Fully automatic, upgradeable fast and latest blood gas and electrolyte combi analyzer. Simultaneously measured following parameters: pH,pCO2., pO2, SaO2, tHb,Na+, K+, Ca++, Cl-, and Hematocrit in one single machine with one single aspiration of blood sample. Calculated parameters which includes BE, BEecf, BB, HCO3-, tCO2, stHCO3-, stpH, ctO2, aH+, AaDO2,MCHC,Anion Gap with COHb & MetHb flagging . Sample volumes – 75 micro lit max Sample throughput – 30 samples / hour Fast analysis time - maximum 50 sec to results. Maintenance free electrodes with individual electrodes ON / OFF facility Fully automatic liquid calibration of all parameters at user-defined intervals without the use of Gas equilibrated reagents, external gases, tanks & regulators. Reagents should be in separate bottle which can be individually replaceable( Not one pack system) Continuous reagent level monitoring with graphic display. Automatic sample device recognition. Upgradeability for auto QC . Data display on well illuminated 5” LCD color touch screen display. Data printout on in built graphic printer. Storage facility of measured data in case of power failure. Built in data storage facility for at least 25,000 patient results 56 20 Pulse Oximeter 21 Infant Radient Warmer Built in QC analysis software for Levy Jennings. Built in barcode reader. Built in optional Auto QC facility. RS 232 interface facility. Built in Network and remote control facility. Built in voltage stabilizer for the range of 100 – 240 V / 50 Hz with 601-1 compliance Should be latest model and FDA approved. It should have at least 5” screen display Spo2%, pulse rate, Plethesmograph waveform, bar graph, alarm for high low status. Trend for 24 hrs. It should have Adult and neonetel probe. It should Microcomputer based temperature controller. It should have both manual and servo modes of temperature control. It should have Skin/ Air/ Manual mode. It should have High temperature cut off system temperature alarm for both skin and air (skin, +- 1 degree C alarm, Skin >38 degree alarm, air over temperature alarm, sensor failure alarm, heater failure alarm) It should have Halogen examination lamp It should have Heater wattage of 600 watts In manual mode unit the user is able to control heater outputs as well as time duration limit for manual mode. It should have APGAR timer, attend baby alarm, It should have set temperature range skin 25 C- 39 degree C, Air 25 degree C – 39 degree C, resolution 0.1 degree C Unit should have easy access from all sides with thick Acrylic collapsible side panels. Unit should have Acrylic baby tray with infants head up/ down facility and foam mattress. S.S tray with slot to use under surface photo therapy 22 Infant Open care system It should Microcomputer based temperature controller It should have both manual and servo modes of temperature control It should have Skin/ Air/ Manual mode It should have High temperature cut off system temperature alarm for both skin and C alarm, Skin >38 degree alarm, air over temperature alarm, sensor failure alarm, he It should have Halogen examination lamp It should have Heater wattage of 600 watts In manual mode unit the user is able to c heater outputs as well as time duration limit for manual mode. It should have APGAR timer, attend baby alarm, It should have set temperature rang degree C, Air 25 degree C – 39 degree C, resolution 0.1 degree C unit should have easy access from all sides with thick Acrylic collapsible side panels Unit should have Acrylic baby tray with infants head up/ down facility and foam mattr to use under surface photo therapy Unit should have Vital sign monitor minimum 5 parameters: spO2, NIBP, temp., ECG 96 hrs trend with colored screen display size minimum 7.4" screen with battery backu should be based on nellcor technology. review of ECG should be available . It should Y sensor probe, temp probe ECG cable should be provided as standard accessories to Central Nursing Station. wireless connectivity should be possible upto 16 beds. Unit should have syringe mounted on side pole of the warmer it should have Volume Automatic calculation of infusion amount having feature of keeping vein open by low blood coagulation, it should have drug liberary also. Uses different brands of syringe ml -50 ml Power supply 220-240 volts and battery backup facility Volume setting rang depending on size of syringe. 23 Double Surface phototherapy Should have compact fluorescent lamps blue & white on both surfaces (double surface ) It should have 4 blue and two daylight CFL lamps on upper surface and 2 57 24 Single Surface Phototherapy unit 26 Neonatal Crib 27 X – Ray view Box 28 NEWBORN CPR MANIKIN 29 Hand sterilizers 30 Phototheray Eye band blue and two daylight CFL lamps on lower surface. Should provide irradiance of over to 10uw /cm2/ min in 420-480 nm range Should be mounted on high quality castors with locking mechanism Should have provision for easy adjustment of height and side positioning It should have detachable cradle. It should run on run on 200-250 volt Phototherapy unit should have Compact fluorescent lamps blue & white on both surfaces (double surface ). It should have 4 blue and two daylight CFL lamps on upper surface and 2 blue and two daylight. Should provide irradiance of over to 10uw /cm2/ min in 420-480 nm range Should be mounted on high quality castors with locking mechanism Should have provision for easy adjustment of height and side positioning It should run on 200-250 volt It should be preprex transparent crib with mattress. Unit should betrendlenburg/ reverse trendlenburg 5 cms castors, I.V. rod. Fluorescent View Box - Specially ultra thin panel X-Ray Film View Box Using External Electrode Fluorescent Lamp Technology, Suitable For Viewing Film Size Up To 14"X17", Light Weight And Slim With Panel Thickness Not More Than 1.5 Inches, To Provide A Uniform Light Pattern With An Output Ranging Between 7000 To 12,000 Lux. The life span should be 20,000 Hrs or more., Easy insertion and removal of films with a automatic switch which turns on with the insertion of the film and turns off when the film is taken out. It should have adjustable brightness control and flicker free high frequency light for reduction of eye strain. It should be light weight ,rugged with no internal parts to break. It should have life like anatomical landmaeks such as nipples,xiphoid process and substernal notch It should have realistic chest rise Ozone discharge controlled , Fully automatic system with wall mounting having features of sterilization in approx. 10 seconds. Sensor technology and timer facility Sterility level approx. 99.9%. 1. It provides the best eye protection from visible light,making it the safest phototherapy mask available. 2. Special eye-pad material blocks more visible light to the baby’s eyes than other normal masks. 3. A soft ,absorbent elastic band holds the eye-pad securely in placeso the baby can’tpull it off. 4. Shape of symbolic animal of the birth year is specially designed.Shape of Ox head for babies born in 2009. 31 32 Bone Marrow Set (Aspiration/biosy) Stethoscope(Pediatric) Good quality CE/ISI mark 58 Tender Group No. VIII GYNAE & OBST. DEPARTMENT NON-CONSUMABLES S. NO. Name of Item 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. 48. Specifications. Outlet Forceps Uterine clamp Kockker’s clamp Mayoma screw Metallic bladder catheter Uterine Manupulator Endo uterine aspiration currette Cusco”s speculum It should be S.S. It should be S.S. It should be S.S.( diff sizes) It should be S.S. It should be S.S. It should be S.S. It should be S.S. Sim’s speculum Post vaginal wall self retaining speculam Mosquito Artery forcep S. shaped vaginal retractor mellables Russian tooth forscep Uterine sound Sponge holder Alli’s forceps Non- toothed forceps Toothed forceps Episiotomy Scissor Suture cutting scissors Mayo’s scissors Needle Holder 6”,8” Vulsellum Basins different size Ovum forceps Cord clamps D&C Set Blunt and Sharp Curette Artery Forceps straight Artery Forceps curved Anterior Vaginal wall retractor Kidney tray Instrument tray with cover Green Armytage Cheatle Forceps E.B. Currette Cidex Tray Doyen retractor Robert artery Right angle forcep Zernis retractor Longeh back retractor Deaver's retractor Towel clips Dressing drums Thermometer CVP SET Cannula and pyramidal It should be S.S. small, medium, large size Long blade It should be S.S. small, medium, large size It should be S.S. It should be S.S. (different sizes) It should be S.S. (different sizes) It should be S.S. It should be S.S. It should be S.S. ((different sizes) It should be S.S. (different sizes) It should be S.S. (different sizes) It should be S.S. 6”, 8” in size. It should be S.S. It should be S.S. 6”, 8”, 10 It should be S.S. 6”, 8”, 10 It should be S.S. It should be S.S. 12”,15”,18” It should be S.S. It should be S.S. It should be S.S. It should be S.S. It should be S.S. 6”, 8” It should be S.S. 6”, 8” It should be S.S. It should be S.S.(diff sizes) It should be S.S. (diff sizes) It Should be SS, (different sizes) It Should be SS, (different sizes) It should be S.S. (different sizes) It should be S.S. (different sizes) It should be S.S. (different sizes) It should be S.S. (different sizes) It should be S.S. (different sizes) It should be S.S. (different sizes) It should be S.S. It should be S.S.(diff sizes) Fixed and flexi tip mercury free it should be with double luman and with single luman. 10/11 mm cannula and pyramedal trocar with valve and 59 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63. trocar Pyramidal Trocar with valve and stopcock L-Shaped hook Spatula Electrode Suction irrigation cannula Bipolar cable Bipolar forceps Atraumatic grasper Toothed grasper Maxigrip Maryland Dissector Metzenbaum Scissor Hook Scissor Babcock Forceps 5mm Rotatable and dismentable with and without ratchet handle insulated 32cm long Clip Applicator Needle holder with ratchet 64. Reusable Hassan trocar 65. Laparoscopic needle holder 66. Self righting Optical cleaning system 67. stopcock for insufflator tubing 5/5.5mm cannula and pyramedal trocar with valve and stopcock for insufflator L- shaped hook electrode insulated 5mm Spatula electrode insulated 5mm Suction irrigation cannula with pistol handle system Bipolar cable to be attached to bipolar forceps Bipolar forceps 32cm long 5mm Atraumatic grasper 5mm Rotatable and dismentable with and without ratchet handle insulated 32cm long Toothed grasper 5mm Rotatable and dismentable with and without ratchet handle insulated 32cm long Maxigrip 5mm Rotatable and dismentable with and without ratchet handle insulated 32cm long Maryland Dissector 5mm Rotatable and dismentable with and without ratchet handle insulated 32cm long Metzenbaum Scissor 5mm Rotatable and dismentable with and without ratchet handle insulated 32cm long It should be 5mm Rotatable and dismentable with and without ratchet handle insulated 32cm long It should be 5mm Rotatable and dismentable with and without ratchet handle insulated 32cm long It should have medium large clips Needle holder with ratchet Reusable Hassan trocar for laparoscopy Reusable ,1012mm,blunt tip Laparoscopic needle holder 5 mm self- righting for allowing automatic upright positioning of Needle at different angles to the instrument shaft.Approx length 310mm Self righting Laproscopic needle holder 5mm -310mm It should provide cleaning of lens without removing telescopes System to have tubing, irrigation syringe, suction tube etc. for 10mm telescopes for approx. 300mm length 69. Disposable laproscopic scissors Monopolar cable 70. FIBRE OPTIC CABLE FIBRE OPTIC CABLE 4.8, 230 cm long to be attached to telescope with light source Maryland Grasper forscep Uterine Manupulator forcep Tripolar cautery forcep Fan retractor Dissector Delivery Bed It should be standard sizes It should be standard sizes It should be standard sizes It should be standard sizes 5mm, 10 mm Three Sectional Stainless Steel top. Epoxy Powder coated frame & assembly. Large Perineal Cut. Hydraulic height adjustment from 550mm to 920mm with pedals on both sides. Pneumatic stepless adjustment for back section 700 for Tredelenburg and reverse tredelenburg (140 & 30 respectively). Sliding Stainless Steel basin. Additional support bar. Folding foot section (Telescopic Type). Antistatic mattress of 80mm thick. 150mm dia four castors with central Braking and steeling facility. Accessory rails on both sides for fixing accessories. 68. 71. 72. 73. 74. 75. 76. Disposable laproscopic scissors Monopolar cable for laproscopic instruments 60 77. Fetal, maternal monitor 78. Multi functional obstetric table 79. B.P.Instrument mercury free LCD display 80. Medical Video Recording system 81. Gynae Examination Light Mobile O.T. Light 82. Pulse Oximeter 83. Multipara meter Complete with standard accessories I.V. Rod, Lithotomy leg supports. 12.1” high-resolution TFT LCD display, support plug-in large screen display. Standard configration FHR, TOCO, FETAL MOVEMENTS, ECG, SPO2,NIBP,RESP, TEMP, PULSE RATE. Optional twins Built in battery, portable and light wt. Dynamic save and display the monitored information within 48 hrs. Facility to connect with the central monitor. And thermal printer. Multi function table designed for delivery, abortion and gynecological examination. Should be easily operational and with reliable safety. The bed surface should have a back section , a seat section and a leg section. The up and down movement of the back section and the forward and backward tilt of the bed surface should be contrlooed by the wheels. It should have a hydraulic up and down monements. Ht. Adjustments 650x895mm. Max degree of backrest adjustment up 75 degree and low 6 degree. Automatic BP instrument with LCD bar display MERCURY FREE Having following features LCD Digital display system along with vertical LCD bar display for both systolic and Diastolic Measuring method - Oscillometric. BP range - 0-300mmHg with accuracy + 3 mmHg Pulse range = 30-180 per minute, Power source battery. Fixed on wall or on plastic stand having facility to keep cuff. Optional: Stand with wheels for the above. It should have High resolution screen with 170 degree angle of vision, pause and record facility. It should have built in hard drive at least 160 GB. A/V in and A/V out mode, IR remote controlled. I It should have rechargeable battery, input connection composite Video and S video. Unit should have Adjustable height trolley, wheel mounted with articulated arm. LED technology having life of approx. 50000 hours. Power supply 100-240 volts, Power consumption approx. 25 watts. Colour temp. - 5000 K Light adjustable from 25000-50000 Lux Temp increse - Minimum Colour rendering index CRI - 86 Trolley mounted light with lockable wheels and articulated arm. 1. Digital and microprocessor controlled LED Lamps 2. Light Intensity- 100000 Lux, and adjustment by feature touch panel 3. Colour temp - 5000K 4. Colour rendering index CRI - 86 5. Temp Increase on operating field/Operator head - zero deg. 6. LED lamp life approx. 50000 hours 7. Power supply 220-230 volts, consumption approx. 80 watts It should display Spo2%, pulse rate, Plethysmograph waveform, bar graph, alarm for high low status. Trend for 24 hrs. It should have Adult and neonetal probe. It should have 10.2 and15” TFT display with ECG waveform. It 61 91 84. Infusion pump 85. Syringe pump 86. Fetal Doppler 87. Suction machine 88. SCALPLE & SHARPS TRANSFER INSTRUMENT 89. 90. Vantouse cups Video Colposcope Telescope 92 Electronic Co2 Insufflator has arrythemia analysis, ST segment detection Parameters – ECG,SPO2,RESP,TEMP,NIBP Probe – neo/pead/adult Infusion pump having following features:Flow setting 1-1000 ml per hour Dose calculation feature Alarms for error with LED light & buzzer Having battery backup and status of battery charge Keep vein open feature at low speed Peristatic pump method Purge facility i.e rapid flow volume Alarm for bubble, Tube clog, Door open, Flow error , Low voltage Power supply 220-240 volts Volume range 0.1-999.9 ml, Automatic calculation of infusion amount having feature of keeping vein open by low speed to prevent blood coagulation Uses different brands of syringes and different size 10 ml -50 ml Power supply 220-240 volts and battery backup facility Volume setting range 0-1200 ml per hour depending on size of syringe Doppler should battery as well as mains operated; rechargeable batteries ; Digital rate display and with auto correction processing; Built in loud speaker and active noise reduction Light weight and compact unit, portable (hand held) Suction machine ½ HP and 1 HP, 2 lit twin jars noiseless, air control knob, mounted on sturdy base with wheels, ISI marked An instrument to safely transfer scalpels at the time of use or after use , so that whatever way the scalpel is dropped it is parked in the tray in the fashion to avoid injury to the user. It should be GAMMA Sterilized & made of biodegradable material. It should have provision to be used for transfer of other instruments also. Silicon cup diff sizes with hand suction Unit should have high resolution images, Camera with at least 800 pixels, ultra high frequency intensity cold light source in loop shape, even, bright, and shadowless. Video output AV/S-V connectable with TV and monitor. Images can be displayed, captured and stored and printed in real time, step free continuous zoom and focus electronic filter, capable of databasing for managing patient demographics, administrate with doctor’s ID compose, print clinical report with integrated patient images and relevant annotations. Unit should have digital camera, software, video cards color printer and trolley. It should be CE certified. Telescope should be 0 degree 10mm and 30 degree 10 mm enlarged view, rod lens 10mm diameter should be approx 32 cm length . unit should be autoclavable. Electronic CO2 insufflator it should be with pin index connectors, silicone tubing set high Pressure hose, CO 2 bottle empty, with pin index connection, universal wrench, CO 2 gas filter, sterile disposable package of 10, insufflation’s pressure: 30mm hg(max),gas flow 20 Lt./min. Display: digital display of patient pressure and gas flow, clear adjacent bar diagram for set value and actual values , monitoring of insufflations procedure. Optical and acoustical warning signal in case of patient over pressured electronically controlled gas refill, all secondary functions for bottle pressure, gas pre heating, 62 insuflation mode should be clearly displayed on large TFT screen. The unit should be fully driven by touch screen. 93 Display Monitor 94 Xenon Light Source 95 Obstetric Labour Table 96 Ambulance Stretcher 97 Scoop Stretcher 98 Head Immobilizer 99 Stretcher on Trolley with matterss 101 Folding stretcher 102 Foot Step Double 103 Lab Technician Stool 104 Over Bed table 105 Soiled Linen trolley with plastic Bucket 106 Soiled Linen trolley with canvas bag LCD COLOR Monitor, screen 19” with RGB System medical grade It should be Cold light fountain Xenon 300 lamp type: Xenon lamp,300 watt color temp.Ca 6000k, light outlets: 1 continuously adjustable light intensity from 0 to100% by the camera video output signal. Fiber optic light cable size 4.8mm,length 250cm. It should be Capable of transmission of adequate illumination . unit should be driven with a touch screen multi language menu, all information for lamp life time and temp- and light intensity etc. should be displayed on large TFT screen. It should be CE/ISO certified. It should have flash memory of last retaining used . adjust,ment of light intensity 5% to 100% motorized. It should be telescopic with adjustable height approx dimensions is 72” L x 27”w x 24-32” height, tubular frame work,mounted on swiveling castors., it should have S.S. top in three sections with trendlenburg position, adjustable by pneumatic gas spring system, hydraulically height adjustable by foot paddle from side,l backrest section adjustable on ratchet, leg and section can slide under the main section, height adjustable a pair of knee crutches. It should be Pre treated and epoxy powder coated. Should Be CE marked It should be lightweight, strond structure, easy antisepsis, can be automatically folded through the hand control handle. It should made of high quality alloy tubes. Load weight should be upto 120 kg, diameter of the castors should be at least 125 mm. It should be portable, first aid stretcher. It should have a clutch zip design at the middle of the unit and can be divided in to two parts. The stretcher length can be fold or be separated. it should have bearing pressure < 159 kg. It should have multi axis block system to accommodate all hesad shapes and injury positions. It should have direct access to patient ear for better communication and inspection. The blocks should have disposable foam pads straps so as to avoid inconvients of taping. It should have tubular frame work of M.S. pipe, swing away type side railing of S.S>, adjustable I.V. rod, utility tray, cylinder crtridge, castors of 6” diameter with brakes. Epoxy powder coated finish. It should have aluminium poles but folding lengthwise as well as widthwise. M.S. tubular frame fitted with PVC stump. CRC sheet duly double press bent, it should be epoxy powder coated. It should be height adjustable cushioned seat and 5 legs base on castors. It should be adjustable by gear handle, it should be laminated with membrane pressed top, pre treated and epoxy powder coated. It should have push handle at one end, frame work on CRC tube mounted on 10 cms castors, superior quality plastic bucket, pre treated and epoxy powder coated. It should have frame work on CRC tube mounted on 10 cms castors, superior quality canvas bag, pre treated and epoxy 63 powder coated. M.S. tubular frame work mounted 5 cms castors Unit should be approx size 91 L x 50 W cms, frame work of CRC tube mounted on 10 cms castors, height adjust5able by gear handle, epoxy powder coated. Tray size should be 56 L x 40 W cms frame work of CRC tube mounted on 5cms castors, height adjust5able by side knob , epoxy powder coated. Emergency cart of high density resin / steel with plastic framework, having, Defibrillator board, Oxygen cylinder holder, Needle containers. Facility for storing suction tubes, Endotracheal tubes etc. Drawers of different configurations with locks. 107 108 Kick Bucket Instrument Mayo Trolley 109 Mayo Trolley 110 Emergency Trolley 111 Cubical Track System Should be Made of Metal Aluminum Alloy of Box size 1.7 x 20 x25 mm with 50-60 microns thick powder coating in white color finish. Tracks should be bendable to a radius of 300 mm at 90 degree to cover the whole bed. Curtain should be made of Hospital grade premium quality Stain Proof fabric with high quality Nylon Net of 18” and 24” on top. Supporting system should consist of wall bracket Made of CRC steel with powder coating finish, Bridge Clamp Made of Aluminum with white powder coating finish, Roof Suspension Made of aluminum pipe of 12.5 mm & 19.5 mm diameter. The upper circle should be made with aluminum with 50.4 mm diameter thickness. Should be with white powder coating (Outer Surface) finish & are of variable height fixed with the ceiling with anchors, bolts, screws etc. Curtain removable point should be made of SS for simple loading and unloading of curtains. (Also serve as an end hook retainer). Runner should comprise of Wheel type runners are made of Teflon for easy and smooth sliding of the curtain. The price should be quoted for per running feet & should be including installation 112 IV bag holder Should be a 5 bag holder fitted onto the ceiling which should raise and lower without disturbing needles and tubes or causing patient discomfort. Should be made from SS for sanitation. Arms should fold for sterilization & easy storage. Should have a open length of 41.5” & a closed length of 27”. Should have easy one arm operation. Should run on tracks. Installation to be done by the supplier himself. The price should be quoted for per running feet. 113 Cleansing system Should have high velocity & powered jets nozzles of clean filtered air on both the ceiling & walls. The jet air flow of 30.5m/sec should be provided by the adjustable nozzles. Should be plug & play modular unit. Should scrub off particulate matter on the clothing. Should have a 3 pre-programmes offering user selectable full auto, semi-auto, manual modes. Should be based on electric logic circuit to control various operations. Should also have two operation modes of entry only entry & exit also user selectable. Should be provided with a non contact detection system to enable auto operation, of door open/close detection, with magnetic sensors. Should have the option of auto start with infra red detection system to bring in automatic functioning. Should be provided with electric trouble free magnetic door locks. Should be constructed from CR M.S. Epoxy Powder Coated, with Aluminium Framed Glass Door. The outer dimension should be 1725X1000X2400mm & the loading inner dimensions should be 900X900X1950mm. the floor should be 64 grated to act as a dust trap. Should have a 3 filtering process with 10 micron fresh air filter to keep inside air fresh, 10 microns washable pre filter & 0.3 microns dop tested 99.97% efficient HEPA filter. The backbone of the system blower should be of hi-efficiency to make the system effective. Should have a both inside & outside for quick servicing The manufacturer should be ISO & WHO-GMP certified. The product should be CE Marked. 114 115 MEDICAL RECORD TROLLEY CASE SHEET HOLDER 116 117 Monitor Trolley OT pendent 118 Autoclave (Vertical) 119 Autoclave portable 120 laprocator 121 Electro surgical unit ABS framework, table top, Sliding board beneath table top, Approx 30-50 no of layers for file holder with lock. ABS material case sheet holder for patients records. Approx. 150 mm x 250 mm x 30 mm Unit should have approx size 800 mm w x 1408 mm H It should be single arm surgical pendent, rotation within 340 degree and fixed flexibility according to the requirement . it should have pneumatic brakes, medium load capacity, easy manual arm movement. Unit should be vertical high pressure steam sterilizer under pressure of 15 to 20 PSI. triple chamber with inner chamber and steam jacket made of SS sheet reinforced with M.S. sheet, double safety valve, water level indicator, water inlet and drain valves. It should work on 220 volts, total load 4 KW It should be single/double drum made of aluminium alloy with turning on lid highly polished . sixze should be 14” x 16” Single puncture laproscope with side view both 90 degree and 45 degree with a length of 268 mm, and working channel of 6mm. Verus insufflation needle 2.0mm, length 100,120 mm Ring applicator 6mm, 287mm Unit should be Microcontroller based isolated electrosurgical generator having both monopolar and Bipolar outputs designed for all surgical procedures. Smart generator should be able to monitor changes in tissue impedence continuously and adjusts power.Monopolar outputs should have three cutting modes : Low cut forr delicate tissue of laproscopic cases having maximum power of 300 W at 300 ohms. Pure cut for clean , precise cut in general surgery having maximum power 300 W At 300 ohms. Blend mode for cutting with homeostatis having maximum power of 200 W at 300 All cut modes should be able to adjust output power depending on tissue density by less than 15% or 5 W, whichever is greater.It should have three coagulation modes with maximum power of 120 W at 500 ohms, dessicate mode for low voltage contact coagulation suitable for laproscopic and delicate tissue work. Fulgurate mode for efficient non contact coagulation in most applications. Spray moede has randomized spray effect of verifying amplitude and frequency for large tissue areas with minimum depth of necrosis. It should have three bipolar modes with maximum power of 70 W at 100 ohms. Precise mode to have fine control of desiccation in delicate tissue. Standard mode for application at low voltage to prevent sparking. Macro mode for application on tissue with high resistance It should have patient plate monitoring facility and should give 65 audiovisual alarm and deactivate output if contact between patient and patient plate is not proper to eliminate the risk of patient burns. It has two hand switchiong and two foot switching monopolar outputs and one hand switching and one foot switching bipolar output. It has membrane keybord for power setting. It has individual digital display of power for bipolar , monopolar cut monopolar coagulation. It has temperature sensing cooling fan. It has RS 232 serial port to interface with computer to reduce the time ion problem diagnosis. It should be compatable with Argon Beam Coagulator and Ultrasonic aspirator system. It has RF activation port to tell other equipments like ECG or EEG that RF current is being generated. It has RF leakage current less than 150 mA. It should have a minimum of Capacity – 100 L Inner body size(mm) should be minimum : 310*470*800 Should have Quantity of racks – min. 3 Nos. Power supply - 220V Should have Disinfecting time of 3-6hrs. Should have the capacity to hold Various models of endoscopes-including rigidity and tender type: arthroscope, cystoscope, bronchoscope, colon-scope, gastro-scope, duodenumoscope, laryngoscope, and rena-scope and some endoscopes which are not very long. Conventional heatsensitive equipment and bone electric drill, etc. Various plastic products: line box, pipeline, and heat-dissipating cable, etc. All mental, rubber and glass, etc Esp. some medical devices which are susceptible to high temperature, humidity, and erosion. Should have the Efficiency of disinfection - 99.999% The chemical used to disinfect the instruments should be gluteraldehyde 122 INSTRUMENT DISINFECTING CABINET 123 Ethylene Oxide Sterilizer The unit should be made out of stainless steel 304 chambers. Stainless steel back plate as well as S.S./M.S. door. The unit should have individual valves for exhaust, allowing gas in the chamber and for vacuumising. The unit should have vacuum pump, chamber heating and control system. Should be a table top model suitable for 2 Nos. Sterilizing Baskets & should be easily placeable on table size of 2.5’ X 4’. The unit should have fascia panel with all accessories pump etc. are enclosed with stainless steel cover. Gauges and controls should be provided in the fascia panel. This model should be specially designed for Hospitals & Lab. The unit should be suitable for working with 10 : 90 EO : CO2 or 12: 88 EO: F-12 mixture. Dimensions should be 250 (H) X 300 (W) x 550 (D) mm. The manufacturer should be ISO & WHO-GMP certified. The product should be CE Marked. 124 sliding door, Rail construction should be aluminum profile, with hermetic closing. Canopy should be coated aluminum plate in standard RAL9006 aluminum color. Should have stainless steel lever handles on both sides. The door blade should be Anodized aluminum surrounding, 4-sided, blind fixed with thickness of 60 mm flushed on both sides. Door core should be made of CFC-free Polyurethane, thickness 48 mm. The top layer on both sides should be hard HPL plastic laminate of size 6mm. should be provided with gasket on all 4 sides of the door blade to ensure 66 hermetic sealing up to 150 pa over or under pressure. Should have inbuilt window double glazed flushed glass quality should be both sides laminate weight should be approx. 100 KG, & rail and canopy approx. 25 KG. Sliding direction should be DIN-Right or DIN-Left. Inside frame dim should be 1500 x 2100 mm. high (example), Clear opening should be 1380 x 2100 mm. high. The dimensions should be adjustable as per the requirement of the specific door. 125 Ultrasonic Cleaner It should be useful for cleaning of Instruments It should have Latest International Sweep Technology It should be compact one-piece construction; Capacity should be minimum 20 Ltrs. Maintenance should be easy; no moving partsshould be there. It should have esthetic model with non rusting body The tank should be made of 304 Stainless steel dye pressed It should clean all surgical instruments including metallic or plastic parts like suction tips, endotracheal tubes, sharp instruments etc. 126 Bed weighing Scale 127 Dust barrier reusable Mat (2x4ft) 128 Air Purification System 129 RIPPLE BEDS Should have BIM Function self folding Net Capacity: 250 kg, Gross capacity: 500 gross. 100 gm graduation. 1. Should have capacity at least 536 Kg Should have portable air supply unit Should have inflated height 8 inches Should be made of nylon or lectrolite Should have washable transfer pads Should have length at least of 78 inches Should be made of bacteria proof, water proof, static electricity free and launder able material Should have built in stabilization bands to contour patients Should have santi-liner with non magnetic snaps Should have patient security straps Should have able Fully washable & easily dried. Should have able Made of strong material and strong adhesive topping to trap the dust and not interfere with the walking. Should reusable type. Should work the whole year round and can be installed easily with the help of special adhesive supplied with mats. Should contain a bactericide to reduce the footborne microbial contamination by over 9%. Should resistant to most chemicals. Should withstand working temp. between 0°C- 50°C. Should have able supplied with compatible detergent. Should be Wall/Standing Model The body should be 24 Inch X 19 Inch There should be four stage of filtration pre-filter electrostatic Filter Activated Carbon Filter UV-ray sterilization Large graphical LCD with date/time consumption of UVmadiation tube life. low-noise centrifugal blowers Two U.V light inside the body of the equipment, should not be exposed to the naked eyes. Purification area should be approximately 10ft. X 10 tt X 12 ft. AIR MATTRESS FOR BED SORE PREVENTION TUBE TYPE 6-8” tubes, should have facility to change single tube, with polyuetherane covering for easy cleaning the pump should be 67 130 131 132 Forcep for skin stapler DOPPLER WITH TWIN MONITORING FINGERTIP PULSE OXIMETER 133 Laparoscopic Humidifier light wt. with capacity to deliver air at 3-5 ltr per min. should have alarm for low pressure and power failure. Forcep for application of absorbable skin stapler Doppler With Twin Facility Having Two Probes For Twin Monitoring Simultaneously With Two Display At A Time Should have color display for pulse rate and SPo2. should have bar and wave form display. Should have different size for paeds. And adult finger. it should have sterile heated limb with dual heating element to maintain temperature and humidity all the way to the patient. The outer tubing provides insulation and aids flexibility. Tubing is connected with a standard male luer lock connector with swiveling lock for easy connection to any laparoscopic probe. should contain a humidifier chamber Should have dry tubing for connection from Insufflator to humidifier chamber, filter. Should have male to male connector to connect filter to heated limb to purge air from tubing before entry to patient. 134 Laminar Air Flow 135 Chair Cum Trolley Stretcher Should be automatic loading stretcher with capacity to covert into wheel chair Should have completely overturnable side protections Should have loading capacity 160-180 Approx size 190 X 56 X 82-85 cm 136 Makler Counting Chamber 137 Instrument & Medicine Cabinet 138 High Pressure Vertical Steam Sterilizer Should be made from SS Should have lockable doors Should have adjustable sS/Glass shelves The machine should covered with stainless steel sheet for aesthetics and convenience. Should have digital time & temperature controller. should have choice selection of rapid or natural cooling or drying Should have CE marked. 139 Cryo Container 140 Pneumatic Curtain 141 O.T. Light (ceiling) with doom with camera and LCD arm (Single/Multipal Doom) Should assist in maintaining a turbulence free environment when every time the door is opened. Should create an invisible curtain to contain the movement of dust/microbes/bacteria etc. when the door is opened or left opened. Should be designed with the latest air barrier technology. Should give thick air curtain with suitable air capacity as per the size of the door. Should also maintain a high level of cleanliness by removing the possibility of dust particles from entering the clean environment. Should work on single phase, 220V, 50Hz, AC supply. Should be constructed from CRC sheet heavy duly powder coated. Should work on the heavy duty centrifugal technology using well balanced blowers. Should conserve energy by prohibiting temperature loss in controlled atmosphere areas. Should be provided with clamps for mounting. The manufacturer should be ISO & WHO-GMP certified. The product should be CE Marked. Should have high resolution Video Camera Should have shadowless effect and focusing depth Compatible with laminar air flow in the O.T. Should have stable electric performance 68 Should have backup build changeover system CE Marked Consumables for Gynae S.No. 1 Name of Item System pack for Sterigen SG400 2 SELF RETAINING RETRACTOR 3 I.D BANDS 4 HAND PORT SYSTEM 5 DIRECT DRIVE GRASPER 6 SEPARATOR 5MM WITH TROCAR 7 SEPARATOR 12 MM WITH TROCAR 8 SEPARATOR 11MM WITH TROCAR 9 SEPARATOR 15MM WITH TROCAR 10 DISPOSABLE TIP NON BLADED TROCAR SYSTEM 12MM Specification Disposable self retaining retractor,Must provide 360 degree retraction,Must have the ability to prevent abdominal wall contamination,Must have the ability to adjust as per the wall thickness Transparent pu material for excellent conformability it should be made of nylon or any good material with facility to write name age sex and ward no. Gel based hand access device,Must have gel based seal only,Must provide 360 degree retraction,Should not strangle hand and allow free movement,Side locking mechanism for gel cap,Must allow insertion of trocar thru seal cap even hand is inserted Disposable atraumatic grasper with mesh covered ptica jaws, Must be disposable 5mm Wide opening jaws with mesh covered polymer pads for 100% atraumatic grasping One finger tip ratchet design for smooth locking Disposable sequential helical tip non bladed trocar 5mm, Must have a sequential helical design for total atraumatic insertion, Must not have any type of metallic or plastic blades on the obturator, Must have seal tabs for easier removal of specimen and rapid desufflation Shielded septum design for prolonged use.length-55mm, 100mm, 150mm Disposable sequential helcal tip non bladed trocar 12mm, Must have a sequential helical design for total atraumatic insertion, Must not have any type of metallic or plastic blades on the obturator, Must have seal tabs for easier removal of specimen and rapid desufflation, Shielded septum design for prolonged use , Universal seal to accommodate any 5 mm to 12 mm instrument.length-55mm,100mm,150mm Disposable sequential helical tip non bladed trocar 11mm, Must have a sequential helical design for total atraumatic insertion, Must not have any type of metallic or plastic blades on the obturator, Must have seal tabs for easier removal of specimen and rapid desufflation Shielded septum design for prolonged use.length55mm,100mm,150mm Disposable sequential helical tip non bladed trocar 15mm, Must have a sequential helical design for total atraumatic insertion, Must not have any type of metallic or plastic blades on the obturator, Must have seal tabs for easier removal of specimen and rapid desufflation Shielded septum design for prolonged use. Length100mm,150mm Must have spaceguard technology, Must have the ability to minimize the trocar entry before ptical tions to avoid injury, Must have the ability to release the abdominal vacuum upon 3mm entry, Must have scope lock and pneumo seal for scope, Must have a sequential helical design for total atraumatic 69 insertion, Must not have any type of metallic or plastic blades on the obturator, Shielded septum design for prolonged use, Universal seal to accommodate any 5 mm to 12 mm instrument length 100mm and 150mm 11 DISPOSABLE LAPAROSCOPIC SCISSOR WITH DUAL CUTTING EDGE must be hand sharpened for excellent cutting edge must have dual cutting edge for cutting different type of tissue blades should be made of 400 series stainless steel only for prolonged life and heavy usage sizes of 35 cm and 45 cm 12 12 MM HASAN TROCAR must have 12mm blunt tip trocar ptica type, must have universal seal, two layered universal seal, lowest housing profile, only non-bladed ptical tip 13 VASCULAR CLAMPS DISPOSABLE INSERTS 14 Gel port Ballon trocar The inserts should disposable and interchangeable the inserts should made of mesh covered latis material to provide full atraumatic grasping in various sizes varying from 30mm to 90mm straight, curved and sidebite must provide different design combinations for different vessels. Gel port Ballon trocar system 12mm length-100mm,150mm 15 Oxidised cellulose Normal weaving, all size Thick weaving, all sizes 16 Delivery Kit Dripping Sheet (Antibacterial), Lithotomy sheet (With Leggings & Funnel Attached), Draper, Cord Clamp(2pcs.), Gynae Pad(5pcs.) 17 Caesarean Kit OT Gown,Face Mask, Frill Cap, Gynae Surgi Sheet (150cm X 200cm-sheet, 15cm X 20cm-incise area), Plain Drape, Hydrophilic Lint Free Sponge with radio opaque wire(3pc), Surgical Pad with Adhesive 18 Surgical Pad Hydrophilic, Lint free, Sterile Surgical Pad, with & without adhesive, size-10cm X 10cm, 10cm X 20cm, 5cm X 5cm (Pad) & 7.5cm X 7.5cm (Adh.),7.5cm X 7.5cm (Pad) & 10cm X 10cm (Adh.), 5cm X 10cm (Pad) & 7.5cm X 12.5cm (Adh.) 19 20 21 Baby Kit Trolley Cover Antimicrobial sealant 22 Sterile Wrap 23 Finger squeeze alcohol based Anti Bacterial processed Baby Cap,Nappy,Shirt & Mattress with wraparound & PVC Lining, with mosquito net for face Trolley Cover (Tyvec), Impervious & Autocleavable, size-27” X 36”, 36” X 54” Antimicrobial sealant intended for use prior to surgical incisionnon-flammable,latex free, non irritating and non-cytotoxic. Coverage area: 25cm*25cm and 50 cm * 25 cm. individually packed. SMMS fabric water resistant, flame resistant LOW linting Compatible with Steam EO and Plasma, All size Finger squeeze alcohol based hand sanitizer which may be 70 hand sanitizer worn/put on belt. It should be in a cartridge with an integrated no drip valve. Capacity should be enough for one full work shift 24 25 Disposable Vomit bags Instrument cleanser Made of biodegradable material having closing facility. 100 gm solution contains non ionic surfactant & alkyl dimethyl benzyl ammonium chloride. 26 27 Anti microbial hand & skin cleansing lotion Mild cleaning foam for prevention & management of bedsores 28 Antimicrobial skin gel with ethyl alcohol 75%. 29 SHARP CONTAINERS contains aqua sodium lacerceth seelfate, sodicem cbloride, alcohol denat, disodium cocoanphodiacetate PEG 200 glyceryl Should contains: aqua, alchohal denat, sodium laureth, PEG-7 glyceryl, cocoatedibuthyl adipate, farnesol, sorbic acid. Disposable and unpeiercable round containers of various sizes - Shutter Blade Lids with needle removing provision. Should be made of ecological plastic material and polypropylene copolymer colored with master batch without heavy metals and cadmium. Thickness should be 1.6 mm bottom and sides. 1.8mm lid and closure. 30 31 32 33 Umbilical Clamps Disposable abdominal drainage system Female urine catheter Surgical Pad (Sterile) 34 Gauze Swab 35 Gauze swab X-ray Detectable min. Should be suitable for autoclave at 134 degree for 25 - Should must have quality standard NF mark/FDA approval & Should comply to ADR Norms. It should be female metallic Urine catheter Dressing pads sterile made of non-woven spunlace fabric at least 30gsm Size 10 X 10 10 X 15 10 X 20 Made of non-woven spunlace fabric at least 30 gsm sizes 10 X 10 X 8 7.5 X 7.5 X 8 5X5X8 Made of non-woven spunlace fabric at least 30 gsm should be x-ray detectable. sizes 10 X 10 X 8 7.5 X 7.5 X 8 71 5X5X8 36 37 Abdominal sponges with X-ray detectable Catherization tray 38 Antivirus Kit 39 40 41 42 43 44 45 46 47 Sperm Wash Sperm Filter Sperm Cryo Tissue Culture Medias Vaginal Speculum Centrifuge Tube Semen Collection Container Cryovials IUI Catheters (Different Sizes) 48 49 Pasture Pipette Cesarian/Abdominal Fluid Collection Drape 50 Under Buttock Drape 51 Skin stapler 52 Disposable bed linen 53 Dressing Kit (major) 54 Dressing Kit (miner) 55 Stitch Removal pack 56 57 58 Abdominal sponges with X-ray detectable Should be made of non-woven spunlace fabric at least 30gsm sizes 25 X25X 4 & 6 PLY 30 X30X 4 & 6 PLY 35 X35X 4 & 6 PLY Operation Kit (major) Minor Operation /Procedure Kit Electrosurgical Pencil with Lead It should contain foley’s catheter, plastic forceps, cotton balls pre-filled 20 ml syringe , lubricant, urine bag, test tube -1, gauze pad, tenestratel drape, gloves, kidney shape basin Flip tip endotractal tube & non woven swab. Should have antivirus apron, Cap, Mask, Shoe Cover, Gloves, Goggles, Cesarian/abdominal fluid collection drape, (254cm*183cm*305cm), having 33cm*33cm adhesive incise area,360 degree fluid collection pouch,foam band, with suction port,having tube holders and armboard covers.,sterile. Under Buttock Drape with fluid collection pouch, 102cm*112cm with absorbent pad, sterile. Subcuticular absorbable skin stapler containing 25 polyglactin pins. Should made up of nonwoven spunlace fabric, 40 gsm laminated with 12 micron LDPE, color : blue, green, and white. Size should be 6ft x 3.5 ft It should contain dressing forcep, tray with gallipots, cotton balls, gauze swabs, absorbant dressing pad 4”x4”, hand wipe tissue,disposable bag It should contain dressing forcep, cotton balls, gauze swabs, absorbant dressing pad 2.5” x 7”, hand wipe tissue,disposable bag It should contain dressing forcep, cotton balls, gauze swabs, absorbant dressing pad 2.5” x 7”, hand wipe tissue,disposable bag,, long stitch cutter with handle. Should contain gown, trolley sheet , drape sheet , drape sheets, abdominal sheet, absorbant dressing pads, paking rolled gauze, abdominal sponges, operatingpeanuts, cotton balls, gauze swabs kidney tray, bowls, hand-wipe tissues, disposable bag Should contain sterile drape , dressing forcep, tray with gallipots, cotton balls, gauze swabs, absorbent dressing pad , hand-wipe tissues, disposable bag hand operated, with removable non stick electrode, with cable. 72 Tender Group No. IX Radiology Department S.No. 1 2 3 Name of Item Barium Enema Equipment with complete Accessories Cassette Box of all sizes Chest Stand 4 Intensifying Screen for cass ettes of following sizes 5 6 Lead Apron (all sizes) Lead Goggles (Front & side), for fluroroscopy Lead Marker 0 to 9 (size 3/4") Lead Marker A to Z (size 3/4") Lead Screen (3 Panel) for Prevent ion of radiation for dental x-ray machine Lead Skirt and Vest Set Light Weight Zero Lead Aprons 7 8 9 10 11 12 Specification Floor Model & Heavy duty with auto loc king arrangements a) (size 17" x 14") b) (size 14 x 14) c) (size 12 x 15) d) (size 10 x 12) e) (size 10 x 8) f) (size 6 1/2 x 8 1/2) X-Ray & Imaging Film Digitizer System 73 Product quoted should be lead free and international certification Radiation protection apparel should incorporate high quality protection sheet of even thickness and uniform distribution of lead. Protection sheet should be flexible and not prone to cracks and pin holes. Lead bonding and PVC /Rubber to create protective sheeting composition should be lead minimum 80 and PVC/Rubber 20. Ratio should be 80:20 Weight should not exceed 3.3 kg /Sq.m. Lead equivalence of 0.5mm (pb) All models should have anti skid pads resulting in comfort of wearing over shoulders. Belt should be provided inside to avoid back stress. Side cuts should be there for ease of movement (walk) X-Ray and imaging film digitizer system for digitization of X-Ray, CT-Scan, Ultrasound & MRI films. It should accept all the film sizes ranging from 5” x 7” to 14” x 17”. Scanning should be based on Professional µ Lens CCD technology. The gray scale resolution s hould be minimum 16 bits. The scanning speed should be less than 18 seconds for 14” X 17” film size. The spatial resolution should be 40800 pixels/line (approximately). The optical density of the system should be upto 3.2D. 13 ‘X’ ray film of various sizes 14 X – Ray view Box (Single Double & Triple Panel) 15 Image Work Station 16 X-ray film Digitizer Scanner should have USB hardware interface. It should be capable of storing scanned images in DICOM, JPEG and BMP format. The output DICOM format image should be compatible with PACS network . The digitizer should have a work station having 17” LCD & should be capable of processing image data of the scanner. It should have a DVD writer, 1 Gigabytes Ram, 100 Gigabytes storage. It should have post process ing facilities lik e windowing, scaling, multi-graphics processing, image division functions, image flipping & rotating, Image zooming, annotation, measurement, Cropping, cine play, text writing, Edge detection, gray equalization, contrast equalization. It should be compatible with DICOM film Sizes are ; 6½“X8½“ 8” X 10” 10” X 12” 12” X 15” 14” X 14” 14” X 17” Fluorescent View Box - Specially ultra thin panel XRay Film View Box Using External Electrode Fluorescent Lamp Technology, Suitable For Viewing Film Size Up To 14"X17", Light Weight And Slim With Panel Thickness Not More Than 1.5 Inches, To Provide A Uniform Light Pattern With An Output Ranging Between 7000 To 12,000 Lux. The life span should be 20,000 Hrs or more., Easy insertion and removal of films with a automatic switch which turns on with the insertion of the film and turns off when the film is taken out. It should have adjustable brightness control and flicker free high frequency light for reduction of eye strain. work station having a high resolution 2 Mega pixel or more monitor with 2GHz processor, CD/DVD recorders, 200GB or more HDD, software capable of capturing image from DICOM compatible equipments and route the images to other locations, for advanced image processing and documentation. Unit should have scanning mode-16 ft gray scale, 12 to 8 bit conversion(256) optimize grey level. Scanning speed 300 epi (4x4k) 30 sec.. and 150 dgi 2x2 k 12 sec, integrated light box, scanned and original images can be compared immediately.. Large media size – upto 14” x 17” DICOM – 3.0 interface for DICOM complience system, PACS and tele radiology, power supply100 – 250 AC COMPUTER – it should be supplied with CPU , Pentium IV/ intel duo core, minimum 1 GB RAM, window HP, video card 64 MB supported modem, network card for DICOM, 240 GB hard disk, dual interface – fire wire or high speed USB interface, fire 74 wire card and cables. 75 Tender Group No. X Refilling of Medical Gases S.No. Name of Item 01 Oxygen Cylinder “A” Type 02 Oxygen Cylinder “B” Type 03 Oxygen Cylinder “D” Type 04 Nitrous Oxide “A” Type 05 Carbon diOxide Cylinder 76