APPARATUS OPERATOR – AERIAL DEVICE FINAL EXAMINATION Name _______________________________________ Course # 79-____________ Circle the correct answer. 1. Which NFPA Standard governs the Service Testing of aerial apparatus? A) B) C) D) 1901 1921 1914 1971 2. An aerial is load tested at what capacity? A) B) C) D) 250 Lbs. 500 Lbs. 1000 Lbs. The manufactures recommendations 3. What items have an impact on legal ramifications? A) B) C) D) State Motor Vehicle and Traffic Laws Organizational SOP’s/SOG’s Nationally recognized standards All of the above 4. What NFPA standard governs the requirements of new fire apparatus? A) B) C) D) 1901 1921 1911 1971 5. Aerial devices are typed into how many categories? A) B) C) D) 2 5 4 7 Office of Fire Prevention and Control Test Page - 1 APPARATUS OPERATOR – AERIAL DEVICE FINAL EXAMINATION 6. Diverter Valves transfer hydraulic power from _____ to the_____? A) B) C) D) The PTO to the hydraulic pump Outriggers to the Jacks The Outriggers/Jacks to the Aerial device The turntable control to the platform control 7. Lift cylinders are used to? A) B) C) D) Level the platform Raise the outriggers Lift the aerial device Extend the aerial sections 8. Extension of the sections can be accomplished by? A) B) C) D) Winch/cables Hydraulic cylinders/cables Motor/chains All of the above 9. What NFPA standard governs fire apparatus maintenance programs? A) B) C) D) 1901 1914 1915 1972 10. NFPA 1914 suggests a non-destructive test of an aerial device? A) B) C) D) Every 5 years Every year After any accident After any time that the aerial is run 11. Aerial waterways should be tested to what PSI? A) B) C) D) 100, 150, 100 300, 400, 500 200, 250, 300 150, 200, 250 Office of Fire Prevention and Control Test Page - 2 APPARATUS OPERATOR – AERIAL DEVICE FINAL EXAMINATION Office of Fire Prevention and Control Test Page - 3 APPARATUS OPERATOR – AERIAL DEVICE FINAL EXAMINATION 12. Safety pins may be supplied for? A) B) C) D) Stabilizers Outriggers/Jacks Aerial Sections Wheel Chocks 13. Aerials set up on grades of greater than 10% will function at what capacity? A) B) C) D) 0% 100% 50% 75% 14. Power transfer to the aerial from the outriggers/jacks/stabilizers may be? A) B) C) D) Electrical Manual None All of the above 15. The recommended operational sequence for aerials is? A) B) C) D) Extend-Raise-Rotate Raise-Rotate-Extend Rotate-Raise-Extend Extend-Rotate-Raise 16. Aerial failures are commonly caused by? A) B) C) D) Overloading Overextension Operating at low angles All of the above 17. Aerial devices may be used for? A) B) C) D) Ventilation Elevated Fire Attack Rescue All of the above Office of Fire Prevention and Control Test Page - 4 APPARATUS OPERATOR – AERIAL DEVICE FINAL EXAMINATION 18. The scrub area can be defined as:? A) B) C) D) The part of the tire that can hit the curb The part of the platform that will hit the building The area of the building that can be touched by the platform The amount of space that the apparatus needs to turn around 19. Tower Ladder platform water flow capacities can be as much as? A) B) C) D) 250 - 500 GPM 1000 -2000 GPM 500 -750 GPM 750 -1000 GPM 20. A rotation limiter control will? A) B) C) E) Limit the speed of the rotation Limit the number of times you can rotate the turntable Limit the rotation of the aerial when the unit it “short jacked” All of the above 21. Aerial inclinometers generally tell? A) B) C) D) The angle of the platform The angle of the turntable The angle that the aerial is hoisted The angle that the aerial is rotated 22. Section locks should be applied when? A) B) C) D) Any time the aerial is raised When the aerial is used for climbing or water tower operations Any time the aerial is rotated Only in emergencies Office of Fire Prevention and Control Test Page - 5 APPARATUS OPERATOR – AERIAL DEVICE FINAL EXAMINATION 23. The load test should be conducted how often? A) B) C) E) Every 5 years Semi Annually Annually At the Fire Departments discretion 24. The weight on an outrigger may exceed ____ of the weight of the apparatus? A) B) C) D) 100% 75% 50% 25% 25. New aerial devices should not be operated in the_____? A) B) C) D) Unsupported position Cantilever position Supported position Level Office of Fire Prevention and Control Test Page - 6