F30 Accessories/ sundry items for brick/ block

advertisement
Er02
CLADDED WALLS
WITHIN CURTAIN WALLING SYSTEM
H11 CURTAIN WALLING
To be read with Preliminaries/General conditions. The details contained within this proposal are
based on information available at the time of writing and covers the installation of Knauf Insulation
products. Knauf Insulation cannot be held responsible for unknown site conditions or for the
performance of materials within the system other than those manufactured, supplied or branded by
Knauf Insulation. The requirements of all relevant British Standards and Industry Codes of Practice
should be complied with at all times. All clauses that are not applicable should be deleted.
TYPES OF CURTAIN WALLING
110 CURTAIN WALLING_________
Supporting structure: ________
Curtain walling system:
Manufacturer: ________
Product reference: ________
Type: _______
Internal framing member:
Material: _______
Finish: _______
Colour/ texture: _______
Minimum film thickness: _______
External cover cap:
Material: ________
Finish: ________
Colour/ texture: ________
Minimum film thickness: ________
Glazing: _______
Inner pane: _______
Outer pane: _______
Glazing system: _______
Panel/ facing type: _______
External material: _______
External finish: _______
Internal material: _______
Internal finish: _______
Core insulation: _______
Accessories: _______
Incorporated components: _______
Other requirements: _______
KNAUF INSULATION LTD.
PO BOX 10, STAFFORD ROAD, ST HELENS, MERSEYSIDE, WA10 3NS, UK.
TEL: 01744 24022 FAX: 01744 612007 www.knaufinsulation.co.uk
TECHNICAL ADVISORY CENTRE TEL 01744 766666 FAX 01744 766667 E MAIL tech@knaufinsulation.com
REGISTERED OFFICE: STAFFORD ROAD, ST HELENS, MERSEYSIDE WA10 3NS, UK, REGISTERED IN ENGLAND, COMPANY NUMBER 1926842
H11/NBS Version/March 2008
370 THERMAL PROPERTIES
Manufacturer: Knauf Insulation Ltd, PO Box 10, Stafford Road, St Helens, Merseyside, WA10
3NS, Tel: 01744 766600, Web: www.knaufinsulation.co.uk
E-mail: tech@knaufinsulation.com
Method of calculating the thermal transmittance (U-value) of curtain walling/ each zone of
curtain walling: Weighted U-value
Average U-value of curtain walling: ________
Curtain wall zone interfaces: Co-ordinate to achieve required average U-value.
Method for assessing thermal transmittance (U-value) of assemblies: ________
390 AVOIDANCE OF CONDENSATION
Requirement: Notional psychrometric conditions under which condensation must not form
on building interior surfaces of framing members or any part of infill panels/ facings are:
Notional outdoor psychrometric conditions as BS 6229, table A1
Notional indoor psychrometric conditions:
Temperature: ________
Relative humidity: ________
Vapour pressure: ______
430 FIRE STOPPING
Locations: At junctions of curtain walling with compartment walls and floors
Materials and methods of fixing: To ensure fire resistance not less than that specified for
compartment walls and floors
PRODUCTS
780 THERMAL INSULATION
Manufacturer: Knauf Insulation Ltd, PO Box 10, Stafford Road, St Helens, Merseyside, WA10
3NS, Tel: 01744 766600, Web: www.knaufinsulation.co.uk
E-mail: tech@knaufinsulation.com
Material: Earthwool Universal Slab RS45
Thickness: 40mm/50mm/60mm/75mm/100mm
Material: Earthwool Universal Slab RS60
Thickness: 40mm/50mm/60mm/75mm/100mm
Properties: Durable, rot and vermin proof and not degradable by moisture or water vapour
Fixing: Attached to or supported within the curtain walling so as not to bulge, sag,
delaminate or detach during installation or in situ during the life of the curtain walling
KNAUF INSULATION LTD.
PO BOX 10, STAFFORD ROAD, ST HELENS, MERSEYSIDE, WA10 3NS, UK.
TEL: 01744 24022 FAX: 01744 612007 www.knaufinsulation.co.uk
TECHNICAL ADVISORY CENTRE TEL 01744 766666 FAX 01744 766667 E MAIL tech@knaufinsulation.com
REGISTERED OFFICE: STAFFORD ROAD, ST HELENS, MERSEYSIDE WA10 3NS, UK, REGISTERED IN ENGLAND, COMPANY NUMBER 1926842
H11/NBS Version/March 2008