Stainless Steel Partitions CSI 3-Part Spec Guideline Section

advertisement
Bradley Mills Stainless Steel Toilet Partitions
Bradley Mills Stainless Steel Partitions provide a low maintenance, and durable solution for toilet
rooms. Bradley's Permaseal™ panel edge design locks moisture out of the panel cores, preventing rust
forming from the inside out, and backed by a 15-year rust-out material warranty. Bradley's Stainless Steel
Partitions are available in overhead braced, floor braced, ceiling hung, and floor to ceiling configurations,
along with urinal and entrance screens with several mounting options.
Architects, engineers, and specifiers look to Bradley Corporation for innovation in design and leadership in
the development of environmentally conscious products. Bradley Corporation, a member of the U.S.
Green Building Council, the Wisconsin Green Building Alliance, has several products earning certification
by GREENGUARDSM Environmental Institute, and GREENGUARD Children and Schools program.
Bradley eases the specifying process with a seasoned customer service staff and a range of helpful
information tools on an advanced website. For example, easy-to-use sizing software, available on
Bradley's website, allows engineers to quickly determine the correct size Thermostatic Mixing Valves.
Bradley is the industry leader in the manufacture of premium quality commercial plumbing fixtures,
valves, and washroom accessories that appear in the following CSI MasterFormat 2004™ Sections:
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
Section
10
10
10
10
10
10
10
10
10
10
22
22
22
22
22
22
22
22
22
22
22
21
21
21
21
21
21
28
28
28
51
11
42
42
42
42
42
42
42
43
45
46
13.13 – Steel Toilet Compartments
13.15 – Stainless Steel Toilet Compartments
13.16 – Plastic Laminate Toilet Compartments
13.17 – Phenolic-Core Toilet Compartments
13.19 – Plastic Toilet Compartments
13.40 – Stone and Stainless Steel Toilet Compartments
13.13 – Commercial Toilet Accessories
13.15 – Warm Air Dryers (Aerix® Hand and Hair Dryers)
13.63 – Detention Toilet Accessories
26 – Plastic Lockers (Lenox Plastic Lockers)
19 – Domestic Water Piping Specialties (Thermostatic mixing valves)
16.01 – Commercial Lavatories and Faucets (Single and multi-station lavatory systems)
16.02 – Commercial Lavatories and Faucets (Bradley Advocate™ Lavatory System)
16.03 – Commercial Lavatories and Faucets (Bradley Verge™ Lavatory System)
16.04 – Commercial Lavatory Decks and Faucets (Bradley Omni Decks)
16.11 – Commercial Sinks and Faucets
23 – Commercial Showers and Shower Valves
33 – Wash Fountains
00 – Healthcare Plumbing Fixtures (Patient care lavatory units)
00 – Emergency Plumbing Fixtures (Emergency Eyewash Fixtures and Drench Showers)
00 – Security Plumbing Fixtures
Contact Bradley Corporation, Menomonee Falls, WI 53051; Phone: 800-BRADLEY ((800)272-3539) Fax:
(262)251-5817, or visit the Bradley web site www.bradleycorp.com.
Bradley Corporation is an AIA/CES registered provider currently offering six programs earning one (1)
HS&W Learning Unit each; several qualify for sustainable design (SD) credit.
Lenox® and Aerix® are registered trademarks of Bradley Corporation.
Advocate™, Evero™ and Verge™ are trademarks of Bradley Corporation.
GREENGUARD Certification ProgramSM is a service mark of GREENGUARD Environmental Institute.
BRADLEY CORPORATION
10 21 13.15
Page 1 of 10
STAINLESS STEEL TOILET COMPARTMENTS
SECTION 10 21 13.15
STAINLESS STEEL TOILET COMPARTMENTS
PART 1 - GENERAL
1.1
SUMMARY
A.
Section Includes:
1.
Stainless steel toilet compartment partitions[ floor mounted, overhead braced] for
following applications:
a.
b.
c.
Toilet enclosures.
Privacy screens.
Urinal screens.
Specifier: Related Requirements paragraph and subparagraphs are included here for information, but are
frequently deleted from project specifications. If retaining, edit subparagraphs as required to coordinate
with construction documents and components specified.
B.
Related Requirements:
1.
2.
3.
4.
Division 03 Section "Cast in Place Concrete" for compartment anchorage to concrete
substrates.
Division 04 Section "Unit Masonry" for compartment anchorage to masonry substrates.
Division 05 Section "Metal Fabrications" for miscellaneous structural and support metal
components required to secure compartments.
Division 06 Section "Rough Carpentry" for compartment anchorage to frame walls.
Specifier: References Article is included here for information, but is frequently deleted from project
specifications. If retaining, edit subparagraphs as required to coordinate with construction documents
and components specified.
1.2
REFERENCES
A.
ASTM International (ASTM):
1.
2.
3.
4.
5.
ASTM A 240 - Standard Specification for Chromium and Chromium-Nickel Stainless Steel
Plate, Sheet, and Strip for Pressure Vessels and for General Applications.
ASTM A 666 - Standard Specification for Annealed or Cold-Worked Austenitic Stainless
Steel Sheet, Strip, Plate, and Flat Bar.
ASTM A 743/A 743M - Standard Specification for Castings, Iron-Chromium, IronChromium-Nickel, Corrosion Resistant, for General Application.
ASTM B 86 - Standard Specification for Zinc and Zinc-Aluminum (ZA) Alloy Foundry and
Die Castings.
ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building
Materials.
BRADLEY CORPORATION
10 21 13.15
Page 2 of 10
STAINLESS STEEL TOILET COMPARTMENTS
6.
B.
International Code Council (ICC)/American National Standards Institute (ANSI):
1.
C.
ASTM B 221/B 221M - Standard Specification for Zinc and Zinc-Aluminum (ZA) Alloy
Foundry and Die Castings.
ICC/ANSI A117.1 - Accessible and Usable Buildings and Facilities, as applicable to toilet
compartments designated as accessible.
United States Department of Justice:
1.
ADA - Americans with Disabilities Act, Excerpt from 28 CFR Part 36 - ADA Standards for
Accessible Design.
GREENGUARD Environment Institute is an ANSI Authorized Standards Developer that oversees the
GREENGUARD certification program. GEI establishes acceptable indoor air standards for indoor products,
environments, and buildings.
D.
GREENGUARD Environmental Institute (GREENGUARD):
1.
1.3
GREENGUARD certified low emitting products.
ACTION SUBMITTALS
A.
Product Data: Manufacturer's data sheets for each type of product indicated.
fabrication details, description of materials and finishes.
1.
B.
Include
Product Test Reports: When requested by Architect, submit documentation by qualified
independent testing agency indicating compliance of products with requirements.
Shop Drawings: Include overall product dimensions, floor plan, elevations, sections, details,
and attachments to other work. Include choice of options with details.
Specifier: Delete Samples for Selection paragraph if Architect has already made product and finish
selections.
C.
Samples for Selection:
selection.
D.
Samples for Verification: Furnish physical sample of material in selected finish.
1.
E.
Furnish samples of manufacturer's full range of finishes for initial
Size: 2 by 2 inch (52 by 52 mm) minimum, in type of finish specified.
LEED Submittals:
Specifier: Retain below if selecting products with recycled content, applicable to LEED-NC, LEED-CS,
LEED-CI, and LEED for Schools.
1.
Product Data for Credit MR 4: For products having recycled content, documentation
indicating percentages by weight of postconsumer and preconsumer recycled content.
Include breakout costs for each product with recycled content.
BRADLEY CORPORATION
10 21 13.15
Page 3 of 10
STAINLESS STEEL TOILET COMPARTMENTS
1.4
INFORMATIONAL SUBMITTALS
A.
1.5
Warranty: Sample of special warranty.
CLOSEOUT SUBMITTALS
A.
1.6
Maintenance and cleaning instructions.
QUALITY ASSURANCE
A.
Manufacturer Qualifications: Approved manufacturer listed in this section, with minimum [5]
years experience in the manufacture of toilet compartments.
Specifier: Retain paragraph above or below based on project requirements. Retain paragraph below
when owner will allow substitution requests.
B.
Manufacturer Qualifications: Approved manufacturer listed in this section, with minimum [5]
years experience in the manufacture of toilet compartments. Manufacturers seeking approval
must submit the following in accordance with Instructions to Bidders and Division 01
requirements:
1.
2.
3.
Product data, including test data from qualified independent testing agency indicating
compliance with requirements.
Samples of each component of product specified.
List of successful installations of similar products available for evaluation by Architect.
C.
Installers Qualifications: Experienced Installer regularly engaged in installation of toilet
compartments for minimum 3 years.
D.
Source Limitations:
manufacturer.
Obtain toilet compartment components and accessories from single
Specifier: Bradley offers handicapped-accessible toilet compartments conforming to requirements of
ICC/ANSI A117.1. Show accessible unit locations and details on Drawings.
E.
Accessibility Requirements: Comply with requirements of ICC/ANSI 117.1, and with
requirements of authorities having jurisdiction.
F.
Surface-Burning Characteristics: As determined by testing identical products according to ASTM
E 84 by qualified testing agency. Identify products with appropriate markings of applicable
testing agency.
1.
2.
Flame-Spread Index: 0.
Smoke-Developed Index: 0.
Specifier: Bradley's Mills Stainless Steel Toilet Compartments exceed LEED for Schools IEQ requirements
as certified by GREENGUARD.
G.
Indoor Environmental Quality Certification: Provide certificate indicated that products have
been certified under the following programs, or a comparable certification acceptable to Owner:
BRADLEY CORPORATION
10 21 13.15
Page 4 of 10
STAINLESS STEEL TOILET COMPARTMENTS
1.
2.
1.7
GREENGUARD Indoor Air Quality Certified.
GREENGUARD Certified for Children and Schools.
DELIVERY, STORAGE, AND HANDLING
A.
Do not deliver toilet compartments to site until building is enclosed and HVAC systems are in
operation.
1.
2.
1.8
Deliver toilet compartments in manufacturer's original packaging.
Store in an upright condition.
WARRANTY
A.
Special Manufacturer’s Warranty: Provide manufacturer's standard form in which manufacturer
agrees to repair or replace products that fail in materials or workmanship during the following
period after substantial completion:
1.
Stainless Toilet Partitions: Against rust-out: 15 years.
Specifier: Select hardware warranty from following two paragraphs for hardware materials consistent
with those selected.
2.
Chrome Hardware: 5 years.
3.
Stainless Steel Hardware: Lifetime.
PART 2 - PRODUCTS
2.1
MANUFACTURERS
A.
Basis-of-Design Manufacturer: Subject to compliance with requirements, provide products of
The Mills Company, Marion, OH 43302.
1.
2.2
Contact Information: (800)272-3539, fax (262)251-5817; Email info@BradleyCorp.com;
Website www.bradleycorp.com.
MATERIALS
Specifier: Select stainless steel finish from folowing two paragraphs. No. 4 satin brushed is the most
common stainless steel finish for smooth partition surfaces.
A.
Stainless Steel Sheet: A 666, 300 series commercial stainless steel sheet suitable for exposed
applications. Provide smooth material, without creases or ripples.
1.
B.
Provide with No. [#4] [5WL] [leather grain] finish.
Stainless Steel Castings: ASTM A 743/A 743M.
BRADLEY CORPORATION
10 21 13.15
Page 5 of 10
STAINLESS STEEL TOILET COMPARTMENTS
C.
Zinc Aluminum Magnesium and Copper Alloy (Zamac): ASTM B 86.
D.
Aluminum: ASTM B 221/B 221M.
2.3
STAINLESS STEEL TOILET COMPARTMENTS
Specifier: Select among following 4 paragraphs and subparagraphs to coordinate partition mounting
style with Drawings. Be sure to verify the structural supports required for ceiling hung units.
A.
Toilet Compartment Type:
1.
Overhead braced.
a.
2.
Floor anchored.
a.
3.
Basis of Design Product: Bradley, Mills Partitions, Floor to Ceiling, Series
700.
Privacy Screen Type:
1.
Floor anchored.
a.
2.
Basis of Design Product: Bradley, Mills Partitions, Floor Braced, Series 500.
Floor and ceiling anchored.
a.
C.
Basis of Design Product: Bradley, Mills Partitions, Ceiling Hung, Series 600.
Floor and ceiling anchored.
a.
B.
Basis of Design Product: Bradley, Mills Partitions, Floor Braced, Series 500.
Ceiling hung.
a.
4.
Basis of Design Product: Bradley, Mills Partitions, Sentinel, Series 400.
Basis of Design Product: Bradley, Mills Partitions, Floor to Ceiling, Series
700.
Urinal Screen Style:
1.
Wall hung with wing bracket:
a.
b.
2.
Basis of Design Product: Bradley, Mills Partitions, Model No. 2.
Provide chrome plated wing bracket for mounting to wall.
Floor anchored:
a.
b.
c.
Basis of Design Product: Bradley, Mills Partitions, Model No. 3.
Floor mounted, requiring concrete floor, minimum 3 inches thick for anchoring.
Where indicated on Drawings, modify to become floor-to-ceiling mounted by
changing mounting pilaster.
BRADLEY CORPORATION
10 21 13.15
Page 6 of 10
STAINLESS STEEL TOILET COMPARTMENTS
3.
Wall-hung with Brackets:
a.
4.
Basis of Design Product: Bradley, Mills Partitions, Model No. 4.
Government-flanged with Wing Bracket:
a.
b.
Basis of Design Product: Bradley, Mills Partitions, Model No. 5.
Provide with continuous bracket in addition to wing bracket.
Specifier: Bradley stainless steel panels utilize watertight interlocked edges, a protection against
moisture penetration of the panel interior which can result in corrosion.
D.
Door, Panel, and Pilaster Construction, General: Form edges with interlock to provide
watertight fit without crown molding. Braze corners and finish smooth.
1.
2.
E.
Door Construction: 1 inch (25 mm) thick, constructed from 0.0313 inch/22 ga (0.794 mm)
stainless steel.
1.
2.
F.
Provide each door with internal 0.0625 inch/16 ga (1.59 mm) and 0.0781 inch/14 ga
(1.98 mm) welded reinforcements at top and bottom hinge locations, with factory
installed concealed true gravity cam hinges.
Provide pre-punched hole to permit field installation of ADA-compliant concealed slide
latch.
Panel Construction: 1 inch (25 mm) thick, constructed from 0.0313 inch/22 ga (0.794 mm)
stainless steel.
1.
G.
Provide exposed surfaces free of pitting, visible seams and fabrication marks, stains,
telegraphing of core material, or other imperfections.
Core Material: Manufacturer's standard sound-deadening, water resistant honeycomb in
thickness required to provide finished thickness for doors, panels and pilasters.
Grab-Bar Reinforcement:
mounted on units.
Provide concealed internal reinforcement for grab bars
Pilaster Construction: 1 1/4 inch (32 mm) thick, constructed from [0.0375 inch/20 gauge (0.953
mm)] [0.048 inch/18 gauge (1.219 mm)] stainless steel.
1.
Provide pilaster with internally welded bracket suitable to accept minimum 3 inch (76
mm) long, 5/16 inch (7.9 mm ) stainless steel hex bolt for leveling.
Specifier: Retain first paragraph below for overhead-braced toilet partitions.
H.
Specifier:
screens.
I.
Headrail: Extruded anodized aluminum headrail with anti-grip profile. Provide fasteners for
attachment to pilaster and stainless steel brackets to secure to wall.
Retain first paragraph below for floor-anchored, floor mounted , and post-to-ceiling urinal
Shoes: 4 inches (102 mm) high minimum, Type 304 stainless steel with No. 4 satin brushed
finish. Secured to the floor with tamper-resistant screws.
BRADLEY CORPORATION
10 21 13.15
Page 7 of 10
STAINLESS STEEL TOILET COMPARTMENTS
J.
Urinal-Screen Construction: Matching toilet compartment panel construction
Specifier: Retain first paragraph below for floor-anchored, overhead-braced, and post-to-ceiling urinal
screens.
K.
Urinal-Screen Post: Manufacturer's standard post design of [material matching the thickness
and construction of pilasters] [or] [1-3/4-inch- (44-mm-) square] aluminum tube with satin
finish]; with shoe[ and sleeve (cap)] matching pilaster.
L.
Brackets (Fittings):
Specifier: Retain one or both subparagraphs below; if retaining both, indicate locations of each type of
fitting on Drawings or by inserts. If necessary, revise to indicate fitting requirements for specific
applications, e.g., "heavy-duty" urinal-screen brackets.
1.
2.
2.4
Stirrup Type: Ear or U-brackets; [chrome-plated zamac] [stainless steel].
Full-Height (Continuous) Type: Manufacturer's standard design; [aluminum] [stainless
steel].
HARDWARE
Specifier: Retain paragraph and subparagraphs below for projects where standard hardware is adequate
for traffic and use.
A.
Hardware, Standard Duty: Manufacturer's standard chrome-plated zamac castings, including
corrosion-resistant, tamper-resistant fasteners:
1.
2.
3.
4.
Hinges: Self-closing [wrap-around gravity-type] [continuous spring-loaded type]
adjustable to hold doors open at any angle up to 90 degrees, with emergency access by
lifting door.
Latch and Keeper: [Concealed slide latch] [Surface-mounted slide latch] with [wraparound] [flat] rubber-faced combination door strike and keeper, with provision for
emergency access, meeting requirements for accessibility at accessible compartments.
Coat Hook: Combination hook and rubber-tipped stop, sized to prevent door from hitting
compartment-mounted accessories. Provide wall bumper where door abuts wall.
Provide formed L-shaped hook without stop at outswing doors.
Door Pull: Standard unit on outside of inswing doors. Provide pulls on both sides of
outswing doors.
Specifier: Retain paragraph and subparagraphs below for projects where heavy duty hardware is
required for traffic and use.
B.
Hardware, Heavy Duty: Manufacturer's heavy-duty stainless steel castings, including stainless
steel tamper-resistant fasteners:
1.
Hinges: Self-closing [wrap-around gravity-type] [continuous spring-loaded type],
adjustable to hold doors open at any angle up to 90 degrees, with emergency access by
lifting door. Mount with stainless steel through-bolts.
BRADLEY CORPORATION
10 21 13.15
Page 8 of 10
STAINLESS STEEL TOILET COMPARTMENTS
2.
3.
4.
2.5
Latch and Keeper: [Concealed slide latch] [Surface-mounted slide latch] with [wraparound] [flat] rubber-faced combination door strike and keeper, with provision for
emergency access, meeting requirements for accessibility at accessible compartments.
Coat Hook: Combination hook and rubber-tipped stop, sized to prevent door from hitting
compartment-mounted accessories. Provide wall bumper where door abuts wall.
Provide formed L-shaped hook without stop at outswing doors. Mount with stainless
steel through-bolts.
Door Pull: Standard unit on outside of inswing doors. Provide pulls on both sides of
outswing doors.
FABRICATION
Specifier: Retain one or more paragraphs below that correspond to project requirements.
A.
Overhead-Braced Units: Provide manufacturer's standard corrosion-resistant supports, leveling
mechanism, and anchors at pilasters to suit floor conditions. Provide shoes at pilasters to
conceal supports and leveling mechanism.
B.
Floor-Anchored Units:
Provide manufacturer's standard corrosion-resistant anchoring
assemblies with leveling adjustment nuts at pilasters for structural connection to floor. Provide
shoes at pilasters to conceal anchorage.
C.
Ceiling-Hung Units: Provide manufacturer's standard corrosion-resistant anchoring assemblies
with leveling adjustment nuts at pilasters for connection to structural support above finished
ceiling. Provide assemblies that support pilasters from structure without transmitting load to
finished ceiling. Provide sleeves (caps) at tops of pilasters to conceal anchorage.
D.
Floor-and-Ceiling-Anchored Units:
Provide manufacturer's standard corrosion-resistant
anchoring assemblies with leveling adjustment at tops and bottoms of pilasters. Provide shoes
and sleeves (caps) at pilasters to conceal anchorage.
E.
Urinal-Screen Posts: Provide manufacturer's standard corrosion-resistant anchoring assemblies
with leveling adjustment at[ tops and] bottoms of posts. Provide caps, shoes, and covers at
posts to conceal anchorage.
Specifier: Retain paragraph below and revise to suit Project if door sizes and swings are not shown on
Drawings; verify requirements of authorities having jurisdiction.
F.
Door Size and Swings: Unless otherwise indicated, provide 26-inch- (660-mm-) wide, inswinging doors for standard toilet compartments and 36-inch- (914-mm-) wide, out-swinging
doors with a minimum 32-inch- (813-mm-) wide clear opening for compartments designated as
accessible.
PART 3 - EXECUTION
3.1
EXAMINATION
A.
Examine work area to verify that measurements, substrates, supports, and environmental
conditions are in accordance with manufacturer's requirements to allow installation.
BRADLEY CORPORATION
10 21 13.15
Page 9 of 10
STAINLESS STEEL TOILET COMPARTMENTS
1.
3.2
Proceed with installation once conditions meet manufacturer's requirements.
INSTALLATION
A.
General: Comply with manufacturer's written installation instructions. Install units rigid,
straight, level, and plumb. Secure units in position with manufacturer's recommended
anchoring devices.
B.
Install toilet partitions and screens in spaces with operating, temperature controlled HVAC
systems. Shield partitions and screens from direct sunlight.
C.
Clearances: Install with clearances indicated on Drawings. Where clearances are not indicated,
allow maximum 1/2 inch (13 mm) between pilasters and panels, and 1 inch (25 mm) between
panels and walls.
Specifier: Retain paragraph below for stirrup brackets. For solid plastic units, three brackets are
recommended for panel-to-wall and panel-to-pilaster connections to prevent sagging of panel.
D.
3.3
Stirrup Brackets: Secure panels to walls and to pilasters with no fewer than [two brackets
attached] [three brackets attached at midpoint and] near top and bottom of panel. Locate wall
brackets so holes for wall anchors occur in masonry or tile joints. Align brackets at pilasters
with brackets at walls.
ADJUSTING
Specifier: Revise hinge adjustment requirements in this article to suit Project.
requirements of authorities having jurisdiction.
A.
3.4
Verify accessibility
Hardware Adjustment: Adjust and lubricate hardware according to hardware manufacturer's
written instructions for proper operation. Set hinges on in-swinging doors to hold doors open
approximately 15 degrees from closed position when unlatched. Set hinges on out-swinging
doors [ and doors in privacy screens] to return doors to fully closed position.
FINAL CLEANING
A.
Remove packaging and construction debris and legally dispose of off-site.
B.
Clean partition and screen surfaces with materials and cleansers in accordance with
manufacturer's recommendations.
END OF SECTION
BRADLEY CORPORATION
10 21 13.15 STAINLESS STEEL TOILET COMPARTMENTS
Page 10 of 10
Download