View My Resume - Qatarmark.com

advertisement
CURRICULAM - VITAE
Name
Date of Birth
Permanent Address
Mail Id
: A.Jayakumar
: 28.03.1983
: 2/45, Arunthathiyar Street,
Valkinathur, Iyyampudhur PO,
Kolathur-636303, Mettur TK,
Salem DT, TN, India.
+91 4298 251124 Mobile: +91 9894743403
: ajayakumarbe@gmail.com
Passport Number
Marital status
Languages known
: G 3713784 (Valid up to 2017)
: Married
: English, Hindi, Tamil & Telugu
Current Assignment
: Testing & Commissioning Engineer (2009 June to till date)
Educational Qualification : B.E. (E.E.E), 2007, 71 %
Diploma (E.E.E) 2004, 86 %
Key responsibilities:
Supporting testing staff in Engineering, materials specification, and installation and
testing procedures.
1. Ability to apply protection coordination settings, Circuit Breaker setting and
equipment operation for MV and LV schemes.
2. Involved in testing of Substation equipments CT, VT, CVT and Switchgears up to
220KV.
3. Testing of Synchronizing, VFD, SCADA, Control and Relay panels up to 220KV.
4. Testing of Power and auxiliary transformers up to 112MVA.
5. Testing of Backup and auxiliary relays, AC/DC distribution boards.
6. Managing, supervising and submitting contractor’s man power requirements.
7. LVAC & DC system, Battery chargers, Control room and Interface system.
8. Trouble shooting of electrical and control wiring system.
9. Major contributor to the SHE/EHS by ensuring contractors and workers adhered
to the SHE/EHS policy.
10. Coordinate the MV and LV switching, Isolation and lock out Procedures.
11. Coordinate the as build drawings for Engineering designs for power reticulation
and distribution single line diagrams and substation layouts including MV and LV
switchgear and control schemes and MCCs schematic diagrams.
12. Intensively trained in the safety aspects while handling electrical testing.
Page 1/4
Testing Kits Handled:
1. CMC 256,356 – Relay test set
2. Freeja and Sverker760 - Relay test set
3. ODAN, CPC 100 – CT Primary injection kit
4. Oil dielectric, CB analyzer, CT analyzer test kit
5. Contact resistance / break time test kit
Electrical Testing & Commissioning Engineer
Glotech Trading & Contracting WLL, Doha, Qatar
09/06/2009 to till date
1. Testing and commissioning of 132/11KV GIS Barzan Camp-2 SS 132/11KV
Switchgears, CT, VT testing, Scheme check, CT Primary and Secondary
Injection, 11KV Bus bar stability and sensitivity, LVAC & LVDC Testing,
Interlock test, SCADA and Alarm signal check, drawing as built in Phase X
project for Kahramaa through L&T Ltd.
2. Erection, Testing and Commissioning of SCS SCADA Control panels in
substations, Panel Modifications, Drawing as built, Erection witness in Phase IX
project for Kahramaa through Siemens.
3. Testing and commissioning of 40MVA, 66/11KV Power Transformer, and 11KV
Switchgears, VT, Scheme check, CT testing, CT Primary Injection, Bus Bar
Stability Test, Drawing as built in Ezdan Village (Ezdan-3 and Ezdan-4) project
for Kahramaa through Siemens.
4. Participated in the Testing and Commissioning of the Qatalum Aluminum
Smelter Project in Qatar, working for the contractor National Contracting
Company WLL under the EPCM contract with SNC Lavalin International.
5. Principle involvement in Testing of 112.5MVA 220/33KV Transformer, 33KV
Switchgears, Scheme check, Inter trip check, AREVA P132 and SEPAM
Relays tripping Test, CT testing, Transformer oil BDV Testing, LVAC, DCDB
Scheme check, 2*20KVAR Capacitor Bank.
6. Principle involvement in Testing of 20MVA, 33/11KV Transformer, Transformer
Tan Delta, Stability, 11KV Switchgears, Scheme check, Inter trip check, Bus
Bar, AREVA P132 , P632 Relays tripping test, CT testing, Battery Charging and
Discharging.
7. Principle involvement in Testing of 10MVA, 33/6.6KV Transformer, Transformer
Tan Delta, Stability, 6.6KV Switchgears, Scheme check, Breaker Timing test,
Inter trip check, AREVA P132 , P632 ,P127, P220 Relays tripping test, CT
testing, Bus Bar, PDCS Scheme check.
Page 2/4
8. Principle involvement in Testing of 3MVA, 33/0.690KV Transformer,
Transformer Tan Delta, Stability, 690V Switchgears, Breaker Timing test,
Scheme check, Inter trip check, AREVA P132 Relays tripping test, Bus Bar, CT
testing.
9. Principle involvement in Testing of 500KVA, 690/230V Transformer, Scheme
check, LVAC, DCDB Scheme check.
Overall final inspection and Completion before Charging of Substation.
Preparations of cable schedule, modification of drawings as per client request, overall
scheme checking, VT selection & Synchronization, VFD Motor, Capacitor Banks,
CT&VT Primary and Secondary injunction, bus bar & Bus duct Hi-pot test, Up to 40KVA
UPS Testing, Transformer Tan Delta, stability.
Testing Engineer
Power Projects Engineers, Chennai, India
01/10/2008 to 01/06/2009
Maintenance Testing:
1. Principle involvement in Testing of 11kV/415V CT,VT, Electromagnetic relays
and Breakers in INDIAN OIL CORPORATION LTD, Rayapuram Chennai.
2. Principle involvement in Pre Commissioning Testing of Protective relays and
CT in ARS METALS PVT LTD, Gumidipundi Chennai.
3. Principle involvement in Testing of 40MVA, 230/11 KV (TELK) Transformer in
HYUNDAI MOTORS INDIA LTD, Chennai.
4. Principle involvement in Testing of Breakers and Electromagnetic relays in SSD
OIL MILLS LTD, Chennai.
5. Principle involvement in Testing of Electromagnetic relays in SPORTS
STADIUMS (Five Stadiums), Chennai.
6. Principle involvement in Testing of AREVA MICOM P111Relays, Auxiliary and
tripping relays in SOUTHERN RAILWAY LOCO WORKS, Perambur, Chennai.
7. Principle involvement in Testing of Protective relays (MICOM Ritx-210) and
CT’s in SOUTHERN RAILWAY, Velacherry, Chennai.
8. Principle involvement in Testing of Electromagnetic relays and CT in SRI
RAGAVA TEXTILES LTD, Tada, AP.
Page 3/4
Assistant Engineer
INEL Power System Engineers Private Ltd, Chennai, India
13/08/2007 to 24/09/2008
1. Principle involvement in Testing of Distribution Transformer, 11KV Cables,
Static and Electromagnetic (Areva & Easun reyrolle) O/C , E/F & Auxiliary
Relays in TATA PROJECTS LTD, Water Treatment (Purifier) Plant, Tirupur,
TN.
2. Principle involvement in Maintenance and Testing of 11KV/415V Distribution
Transformer, 11KV Cables in 4th WORLD MILITARY GAMES, Stadium Site,
Hyderabad.
Key Responsibility at Factory Testing in Mumbai Siemens Kalwa works:
Involved as a Team leader in testing of all the panels like 11KV to 400KV control and
relay panels in various clients some clients given below
1. Involved in Testing of 132 KV UPPTCL, Line Control & Relay Panels including
Testing & Programming of SIEMENS Numerical Distance & Auxiliary Relay.
2. Involved in Testing of 220 KV WBSEB, Feeder Control & Relay Panels
including Testing & Programming of SIEMENS Numerical Distance & Auxiliary
Relays.
3. Involved in Testing of 2 * 300 MW Reliance Industries Ltd. DCR Thermal Power
Project, Control & Relay Panels including Testing & Programming of SIEMENS
Numerical & Auxiliary Relays.
4. Involved in Testing of 220/110/11 KV KPTCL, Transformer Control & Relay
Panel including Testing & Programming of SIEMENS, AREVA Numerical &
Auxiliary and Tripping Relays.
5. Involved in Testing of 220/132 KV Biharshariff (BSEB), line Control & Relay
Panels including Testing & Programming of SIEMENS, AREVA and EASUN
REYROLLE Numerical, & Auxiliary and Tripping Relays.
6. Involved in Testing of 400KV Adani Power LTD, line Control & Relay Panels
including Testing & Programming of SIEMENS, AREVA Numerical and
Electromechanical Relays.
7. Involved in Testing of 400/220 KV TATA POWER, Tie Relay Panels including
Testing & Programming of SIEMENS Numerical & Auxiliary Relays.
8. Involved in Testing of 400/220 KV TATA POWER, Tie Relay Panels including
Testing & Programming of SIEMENS Numerical & Auxiliary Relays.
--------x--------
Page 4/4
Download