Kinpo Electronics (China) Co., Ltd Scientific

advertisement
Kinpo Electronics (China) Co., Ltd
Scientific Calculator
Model No.: SR260
Prepared for : Kinpo Electronics (China) Co., Ltd
Industrial Area, Shatou Village, Chang An Town, Dongguan
City, Guangdong Province
Prepared By : Audix Technology (Shenzhen) Co., Ltd.
No. 6, Ke Feng Rd., 52 Block,
Shenzhen Science & Industrial Park,
Nantou, Shenzhen, Guangdong, China
Tel: (0755) 26639496
Fax: (0755) 26632877
Report Number :
Date of Test
:
Date of Report :
ACS-J08621
Nov.28, 2008
Dec.03, 2008
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 1 of 24
TABLE OF CONTENTS
Description
Page
Test Report Declaration…………………………………………….………………..…..3
1.
Summary of standards and results ....................................................................................................4
1.1. Description of Standards and Results.................................................................................................... 4
2.
GENERAL INFORMATION ...........................................................................................................5
2.1. Description of Device (EUT) ................................................................................................................ 5
2.2. Test Facility ........................................................................................................................................... 6
2.3. Measurement Uncertainty ..................................................................................................................... 6
3.
Radiated Disturbance test .................................................................................................................7
3.1.
3.2.
3.3.
3.4.
3.5.
3.6.
3.7.
3.8.
4.
5.
IMMUNITY PErFORMANCE CRITERIA................................................................................... 11
Electrostatic Discharge immunity Test...........................................................................................12
5.1.
5.2.
5.3.
5.4.
5.5.
5.6.
5.7.
5.8.
6.
Test Equipment.................................................................................................................................... 15
Block Diagram of Test Setup .............................................................................................................. 15
Test Standard ....................................................................................................................................... 16
Severity Levels and Performance Criterion......................................................................................... 16
EUT Configuration.............................................................................................................................. 16
Operating Condition of EUT ............................................................................................................... 16
Test Procedure ..................................................................................................................................... 16
Test Results ......................................................................................................................................... 16
MAGNETIC field immunity test....................................................................................................18
7.1.
7.2.
7.3.
7.4.
7.5.
7.6.
7.7.
7.8.
8.
Test Equipment.................................................................................................................................... 12
Block Diagram of Test Setup .............................................................................................................. 12
Test Standard ....................................................................................................................................... 12
Severity Levels and Performance Criterion......................................................................................... 12
EUT Configuration.............................................................................................................................. 12
Operating Condition of EUT ............................................................................................................... 13
Test Procedure ..................................................................................................................................... 13
Test Results ......................................................................................................................................... 13
RF Field Strength susceptibility Test..............................................................................................15
6.1.
6.2.
6.3.
6.4.
6.5.
6.6.
6.7.
6.8.
7.
Test Equipment...................................................................................................................................... 7
Block Diagram of Test Setup ................................................................................................................ 7
Test Standard ......................................................................................................................................... 7
Radiated Disturbance Limit................................................................................................................... 8
EUT Configuration on Test ................................................................................................................... 8
Operating Condition of EUT ................................................................................................................. 8
Test Procedure ....................................................................................................................................... 8
Radiated Disturbance Test Results ........................................................................................................ 8
Test Equipment.................................................................................................................................... 18
Block Diagram of Test Setup .............................................................................................................. 18
Test Standard ....................................................................................................................................... 18
Severity Levels and Performance Criterion......................................................................................... 18
EUT Configuration on Test ................................................................................................................. 18
Operating Condition of EUT ............................................................................................................... 19
Test Procedure ..................................................................................................................................... 19
Test Results ......................................................................................................................................... 19
Photographs ....................................................................................................................................21
8.1.
8.2.
8.3.
8.4.
Photos of Radiated Disturbance Test (In Anechoic Chamber)............................................................ 21
Photos of Electrostatic Discharge Immunity Test ............................................................................... 23
Photo of RF Strength Susceptibility Test ............................................................................................ 24
Photo of Magnetic Field Test .............................................................................................................. 24
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 2 of 24
1. SUMMARY OF STANDARDS AND RESULTS
1.1.Description of Standards and Results
The EUT have been tested according to the applicable standards as referenced below.
EMISSION
Description of Test Item
Radiated disturbance
Standard
EN 55022:2006
Limits
Results
Class B
PASS
IMMUNITY (EN55024: 1998+A1:2001+A2: 2003)
Performance
Criteria
B
Description of Test Item
Basic Standard
Results
Electrostatic discharge (ESD)
IEC 61000-4-2:2001
Radio-frequency,
Continuous radiated disturbance
IEC 61000-4-3:2002+
A1: 2002
A
PASS
Power frequency magnetic field
IEC 61000-4-8:2001
A
PASS
PASS
N/A is an abbreviation for Not Applicable.
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 4 of 24
2. GENERAL INFORMATION
2.1.Description of Device (EUT)
Description
:
Scientific Calculator
Model No.
:
SR260
Applicant
:
Kinpo Electronics (China) Co., Ltd
Industrial Area, Shatou Village, Chang An Town,
Dongguan City, Guangdong Province
Manufacturer
:
Kinpo Electronics (China) Co., Ltd
Industrial Area, Shatou Village, Chang An Town,
Dongguan City, Guangdong Province
Date of Test
:
Nov.28, 2008
Date of Receipt
:
Nov.27, 2008
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 5 of 24
2.2.Test Facility
Site Description
Name of Firm
:
Audix Technology (Shenzhen) Co., Ltd.
No. 6, Ke Feng Rd., 52 Block, Shenzhen
Science & Industrial Park, Nantou,
Shenzhen, Guangdong, China
3m Anechoic Chamber
:
Jun. 13, 2006 File on Federal
Communication Commission
Registration Number: 90454
3m & 10m Anechoic Chamber
:
Jan. 31, 2007 File on Federal
Communication Commission
Registration Number: 794232
EMC Lab.
:
Accredited by DATech, German
Registration Number: DAT-P-091/99-01
Dec.20, 2007
Accredited by NVLAP, USA
NVLAP Code: 200372-0
Apr.01, 2008
2.3.Measurement Uncertainty
No.
Item
MU
1 Uncertainty for Conducted Emission Test 2.02dB
Uncertainty for Radiation Emission test in 3.44 dB
2
3m chamber
3.96 dB
3.86dB
Uncertainty for Radiation Emission test in 4.18dB
3
10m chamber
4.02dB
4.36dB
4 Uncertainty for Power Clamp Test
2.82 dB
Remark
Polarize: V
Polarize: H
Distance: 10m Polarize: V
Distance: 10m Polarize: H
Distance: 3m Polarize: V
Distance: 3m Polarize: H
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 6 of 24
3. RADIATED DISTURBANCE TEST
3.1.Test Equipment
Item
1
2
3
4
5
6
7
8
9
10
Equipment
3#Chamber
EMI Spectrum
Test Receiver
Amplifier
Bilog Antenna
RF Cable
RF Cable
RF Cable
RF Cable
Coaxial Switch
Manufacturer
AUDIX
Agilent
Rohde & Schwarz
HP
Schaffner
JINGCHENG
JINGCHENG
JINGCHENG
JINGCHENG
Anritsu
Model No.
N/A
E7403A
ESVS20
8447D
CBL6112D
KLMR400
JBY400
JBY400
JBY400
MP59B
Serial No.
N/A
MY42000106
830350/005
2648A04738
25237
3# Chamber No.1
3# Chamber No.2
3# Chamber No.3
3# Chamber No.4
M73989
Last Cal.
Jun.09,08
May 10, 08
May 10, 08
Jul.08.08
Feb.21, 08
Jul.08.08
Jul.08.08
Jul.08.08
Jul.08.08
Jul.08.08
Cal. Interval
1/2 Year
1 Year
1 Year
1/2 Year
1 Year
1/2 Year
1/2 Year
1/2 Year
1/2 Year
1/2 Year
3.2.Block Diagram of Test Setup
3.2.1. Block Diagram of Test Setup
EUT
(EUT: Scientific Calculator)
3.2.2. In Anechoic Chamber Test Setup Diagram
ANTENNA TOWER
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
3 METERS
EUT and
Support System
1.5m(L)*1.0m(W)*0.8m(H)
TURN TABLE
(WOOD)
0.8 METER
GROUND PLANE
3.3.Test Standard
EN55022: 2006, Class B
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 7 of 24
3.4.Radiated Disturbance Limit
All emanations from a Class B computing devices or system, including any network of
conductors and apparatus connected thereto, shall not exceed the level of field strengths
specified below:
FREQUENCY
DISTANCE
FIELD STRENGTHS LIMITS
(MHz)
(Meters)
(dBμV/m)
30 ~ 230
3
40
230 ~ 1000
3
47
Note:
(1) Emission level = Antenna Factor + Cable Loss + Reading
(2) The lower limit shall apply at the transition frequencies.
(3) Distance refers to the distance in meters between the test antenna and
the
closed point of any part of the EUT.
3.5.EUT Configuration on Test
The EN 55022 Class B regulations test method must be used to find the maximum
emission during Radiated Disturbance test.
3.5.1. Scientific Calculator (EUT)
Model Number : SR260
3.6.Operating Condition of EUT
3.6.1. Setup the EUT and the simulators as shown on Section 3.2.
3.6.2. Turned on the power of all equipments.
3.6.3. Let the EUT worked in test mode (Running ) and tested it.
3.7.Test Procedure
The EUT was placed on a non-metallic table, 80 cm above the ground plane inside a
semi-anechoic chamber. An antenna was located 3m from the EUT on an adjustable
mast. A pre-scan was first performed in order to find prominent radiated emissions. For
final emissions measurements at each frequency of interest, the EUT were rotated and
the antenna height was varied between 1m and 4m in order to maximize the emission.
Measurements in both horizontal and vertical polarities were made and the data was
recorded. In order to find the maximum emission, the relative positions of equipments
and all of the interface cables were changed according to EN 55022 Class B on
Radiated Disturbance test.
The bandwidth setting on the test receiver (R&S TEST RECEIVER ESVS20) is 120
kHz.
The frequency range from 30MHz to 1000MHz is checked. The test result are reported
on Section 3.8.
3.8.Radiated Disturbance Test Results
PASS.
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 8 of 24
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 9 of 24
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 10 of 24
4. IMMUNITY PERFORMANCE CRITERIA
Performance Level
The test results shall be classified in terms of the loss of function or degradation of performance of the
equipment under test, relative to a performance level by its manufacturer or the requestor of the test, or
the agreed between the manufacturer and the purchaser of the product.
Definition related to the performance level:
1. Based on the used product standard
2. Based on the declaration of the manufacturer, requestor or purchaser
Criterion A:
Definition: normal performance within limits specified by the manufacturer, requestor and purchaser.
The equipment shall continue to operate as intended without operator intervention. No degradation of
performance or loss of function is allowed below a performance level specified by the manufacturer when
the equipment is used as intended. The performance level may be replaced by a permissible loss of
performance. If the minimum performance level or the permissible performance loss is not specified by
the manufacturer, then either of these may be derived from the product description and documentation,
and by what the user may reasonably expect from the equipment if used as intended.
Criterion B:
Definition: temporary loss of function or degradation of performance which ceases after the
disturbance ceases, and from which the equipment under test recovers its normal performance,
without operator intervention.
After the test, the equipment shall continue to operate as intended without operator intervention. No
degradation of performance or loss of function is allowed, after the application of the phenomena below a
performance level specified by the manufacturer, when the equipment is used as intended. The
performance level may be replaced by a permissible loss of performance. During the test, degradation of
performance is allowed. However, no change of operating state or stored data is allowed to persist after
the test. If the minimum performance level (or the permissible performance loss) is not specified by the
manufacturer, then either of these may be derived from the product description and documentation, and
by what the user may reasonably expect form the equipment if used as intended.
Criterion C:
Definition: temporary loss of function or degradation of performance, the correction of which requires
operator intervention.
Loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation
of the controls by the user in accordance with the manufacturer’s instructions. Functions, and/or
information stored in non-volatile memory, or protected by a battery backup, shall not be lost.
Criterion D:
Definition: loss of function or degradation of performance, which is not recoverable, owing to damage
to hardware or software, or loss of data.
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 11 of 24
5. ELECTROSTATIC DISCHARGE IMMUNITY TEST
5.1.Test Equipment
Item Equipment
1.
ESD Tester
Manufacturer Model No. Serial No.
Last Cal. Cal. Interval
EM Test
Dito
V0503100053 Jan.15, 08 1 Year
5.2.Block Diagram of Test Setup
5.2.1. Block Diagram of Test Setup
EUT
(EUT: Scientific Calculator)
5.2.2. Block Diagram of ESD Test Setup
EUT and
Support System
ESD
Tester
AC Mains
0.8 m
AC Mains
Remark:
is Discharge Electrode
(EUT: Scientific Calculator)
5.3.Test Standard
EN 55024: 1998+A1: 2001+A2: 2003 (IEC 61000-4-2: 2001)
(Severity Level 1&2&3 for Air Discharge at 2kV&4kV&8kV,
Severity Level 1&2 for Contact Discharge at 2kV&4kV)
5.4.Severity Levels and Performance Criterion
5.4.1. Severity level
Level
1.
Test Voltage
Contact Discharge (kV)
2
Test Voltage
Air Discharge (kV)
2
2.
4
4
3.
6
8
8
Special
15
Special
4.
X
5.4.2. Performance criterion: B
5.5.EUT Configuration
The configurations of EUT are listed in Section 3.5.
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 12 of 24
5.6.Operating Condition of EUT
Same as radiated test that is listed in Section 3.6. except the test set up replaced by
Section 5.2.
5.7.Test Procedure
5.7.1. Air Discharge:
The test was applied on non-conductive surfaces of EUT. The round discharge tip
of the discharge electrode was approached as fast as possible to touch the EUT.
After each discharge, the discharge electrode was removed from the EUT. The
generator was re-triggered for a new single discharge and repeated 20 times for
each pre-selected test point. This procedure was repeated until all the air
discharge completed
5.7.2. Contact Discharge:
All the procedure was same as Section 5.7.1. except that the generator was
re-triggered for a new single discharge and repeated 50 times for each
pre-selected test point. The tip of the discharge electrode was touching the EUT
before the discharge switch was operated.
5.7.3. Indirect discharge for horizontal coupling plane
At least 20 single discharges were applied to the horizontal coupling plane, at
points on each side of the EUT. The discharge electrode positions vertically at a
distance of 0.1m from the EUT and with the discharge electrode touching the
coupling plane.
5.7.4. Indirect discharge for vertical coupling plane
At least 20 single discharges were applied to the center of one vertical edge of the
coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, was placed
parallel to, and positioned at a distance of 0.1m from the EUT. Discharges were
applied to the coupling plane, with this plane in sufficient different positions that
the four faces of the EUT are completely illuminated.
5.8.Test Results
PASS.
The EUT was tested and all the test results are listed in next page.
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 13 of 24
Electrostatic Discharge Test Results
Audix Technology (Shenzhen) Co., Ltd.
Applicant
: Kinpo Electronics (China) Co., Ltd
Test Date
:
Date: 12/03/2008
Nov.28, 2008
Temperature
: 24℃
Humidity
: 52%
Test Mode
: Running
Pressure
: 100.6KPa
Actual
Performance
: B
: A
±2kV ±4kV ±8kV # For Air Discharge each Point Positive 10 times and negative 10
times discharge.
Contact Discharge: ±2kV ±4kV
# For Contact Discharge each point positive 25 times and
negative 25 times discharge
For the time interval between successive single discharges an initial value of one second.
Discharge
Performance
Result
Type of
Dischargeable Points
Voltage (kV)
discharge
Require Observation (Pass/Fail)
A
Contact
1
B
±2
Pass
A
Contact
1
B
±4
Pass
A
Air
2,3,4
B
±2
Pass
A
Air
2,3,4
B
±4
Pass
A
Air
2,3,4
B
±8
Pass
A
HCP-Bottom
Edge of the HCP
B
±2
Pass
A
VCP-Front
Center of the VCP
B
±2
Pass
A
VCP-Left
Center of the VCP
B
±2
Pass
A
VCP-Back
Center of the VCP
B
±2
Pass
A
VCP-Right
Center of the VCP
B
±2
Pass
A
HCP-Bottom
Edge of the HCP
B
±4
Pass
A
VCP-Front
Center of the VCP
B
±4
Pass
A
VCP-Left
Center of the VCP
B
±4
Pass
A
VCP-Back
Center of the VCP
B
±4
Pass
A
VCP-Right
Center of the VCP
B
±4
Pass
Discharge Points Description
1 Screws
6
2 LCD
7
3 Slots
8
4 Buttons
9
5
10
Remark:
Test Equipment:
ESD Tester dito
Discharge should be considered on Contact and Air and Horizontal Coupling Plane (HCP) and Vertical
Coupling Plane (VCP)
EUT
M/N
Test Voltage
Test Engineer
Required
Performance
Air Discharge:
:
:
:
:
Scientific Calculator
SR260
DC 3V
Sun
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 14 of 24
6. RF FIELD STRENGTH SUSCEPTIBILITY TEST
6.1.Test Equipment
Item
1.
2.
4.
5.
Equipment
2#Chamber
Signal Generator
Amplifier
Isotropic Field
Monitor
Manufacturer
AUDIX
Marconi
A&R
A&R
6.
7.
8.
9.
10.
11
12
Isotropic Field Probe A&R
Laser Probe Interface A&R
Model No.
N/A
2031B
Serial No.
N/A
11606/058
100W/1000M1 17028
FM7004
0325983
FP7006
FL7000
Power Meter
Anritsu
ML2487A
Power Sensor
Anritsu
MA2491A
Log-periodic Antenna A&R
AT1080
PC
N/A
486DX2
RF Cable
JINGCHENG KLMR400
0325736
325430
6k00003262
33005
16512
N/A
No.1/2/3
Last Cal.
Aug.21.08
May 10, 08
NCR
NCR
Cal. Interval
1/2Year
1 Year
NCR
NCR
July. 26, 08
NCR
May.10,08
May.10,08
NCR
N/A
NCR
1 Year
NCR
1Year
1Year
NCR
N/A
NCR
6.2.Block Diagram of Test Setup
6.2.1. Block Diagram of Test Setup
EUT
(EUT: Scientific Calculator)
6.2.2. R/S Test Setup
3 Meters
EUT and Support
System
Anechoic
Chamber
0.8 Meter
Measurement
Room
Power Amp
Signal
Generator
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 15 of 24
6.3.Test Standard
EN 55024: 1998+A1:2001+A2: 2003 (IEC 61000-4-3: 2002+A1: 2002)
(Severity Level: 2 at 3V / m)
6.4.Severity Levels and Performance Criterion
6.4.1. Severity level
Level
Test Field Strength V/m
1.
1
2.
3
3.
10
X
Special
6.4.2. Performance criterion: A
6.5.EUT Configuration
The configurations of EUT are listed in Section 3.5.
6.6.Operating Condition of EUT
Same as radiated test that is listed in Section 3.6. except the test set up replaced by
Section 6.2.
6.7.Test Procedure
Testing was performed in a fully anechoic chamber as recommended by IEC 61000-4-3.
The EUT was placed on an 80 cm high non-conductive table located in the area of field
uniformity. The radiating antenna was placed 3m in front of the EUT and Support
system, and dwell time of the radiated interference was controlled by an automated,
computer-controlled system. The signal source was stepped through the applicable
frequency range at a rate no faster than 1% of the fundamental. The signal was
amplitude modulated 80% over the frequency range 80 MHz to 1GHz at a level of 3
V/m. The dwell time was set at 3.0 s. Field presence was monitored during testing via a
field probe placed in close proximity to the EUT. Throughout testing, the EUT was
closely monitored for signs of susceptibility. The test was performed with the antennae
oriented in both a horizontal and vertical polarization.
All the scanning conditions are as follows:
Condition of Test
Remarks
------------------------------------------------------------------------------1. Test Fielded Strength
3 V/m (Severity Level 2)
2. Radiated Signal
80% amplitude modulated with a
1kHz sine wave
3. Scanning Frequency
80 - 1000 MHz
4. Sweeping time of radiated
0.0015 decade/s
5. Dwell Time
3.0 Sec.
6.8.Test Results
PASS.
The EUT was tested and all the test results are listed in next page.
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 16 of 24
RF Field Strength Susceptibility Test Results
Audix Technology (Shenzhen) Co., Ltd.
Date: 12/03/2008
Applicant
:
Kinpo Electronics (China) Co.,
Ltd
Test Date
:
Nov.28, 2008
EUT
:
Scientific Calculator
Temperature
:
25℃
M/N
:
SR260
Humidity
:
52%
Test Voltage
:
DC 3V
Test Mode
:
Running
Sun
Pressure
:
100.6KPa
:
A
Actual
Performance
:
:
80 MHz -1000MHz
Field Strength :
Test Engineer :
Required
Performance
Frequency
Range
Modulation:
; AM
… Pulse
… none
1 kHz
A
3 V/m
80%
Frequency Rang 1:
80 MHz -1000MHz
Steps
1%
Horizontal
Required
Observation
Vertical
Result
Required
Observation (Pass / Fail)
Front
A
A
A
A
Pass
Right
A
A
A
A
Pass
Rear
A
A
A
A
Pass
Left
A
A
A
A
Pass
Test Equipment:
1. Signal Generator: Marconi 2031B
2. Power Amplifier: A&R 500A/100; 100W/1000M.
3. Power Antenna: A&R AT-1080.
4. Field Monitor: A&R FM7004.
Remark:
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 17 of 24
7. MAGNETIC FIELD IMMUNITY TEST
7.1.Test Equipment
Item Equipment
Manufacturer Model No. Serial No. Last Cal. Cal. Interval
1.
Magnetic Field HEAFELY MAG100.1 083858-10 May 10, 08 1 Year
Tester
7.2.Block Diagram of Test Setup
7.2.1. Block Diagram of Test Setup
EUT
(EUT: Scientific Calculator)
7.2.2. Block Diagram of Test Setup
Induction Coil
EUT and
Support
0.8 m
Magnetic Field
Tester
AC Mains
wood
Ground Reference Support
7.3.Test Standard
EN 55024: 1998+A1: 2001+A2: 2003 (IEC 61000-4-8: 2001)
(Severity Level 1 at 1A/m)
7.4.Severity Levels and Performance Criterion
7.4.1. Severity level
Level
Magnetic Field Strength A/m
1.
1
2.
3
3.
10
4.
30
5.
100
X.
7.4.2. Performance criterion: A
Special
7.5.EUT Configuration on Test
The configurations of EUT are listed in Section 3.5.
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 18 of 24
7.6.Operating Condition of EUT
Same as radiated test that is listed in Section 3.6. except the test set up replaced by
Section 7.2.
7.7.Test Procedure
The EUT was subjected to the test magnetic field by using the induction coil of
standard dimensions (1m*1m) and shown in Section 7.2. The induction coil was then
rotated by 90°in order to expose the EUT to the test field with different orientations.
7.8.Test Results
PASS.
The EUT was tested and all the test results are listed in next page.
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 19 of 24
Magnetic Field Immunity Test Results
Audix Technology (Shenzhen) Co., Ltd.
Date: 12/03/2008
Applicant
:
Kinpo Electronics (China) Co.,
Ltd
Test Date
:
Nov.28, 2008
EUT
:
Scientific Calculator
Temperature
:
25℃
M/N
:
SR260
Humidity
:
52%
Test Voltage
:
DC 3V
Test Mode
:
Running
Test Engineer
:
Sun
Pressure
:
100.6KPa
Required
Performance
:
A
Actual
Performance
:
A
Testing Duration
Coil Orientation
1A/m
5 min / coil
X
A
A
PASS
1A/m
5 min / coil
Y
A
A
PASS
1A/m
5 min / coil
Z
A
A
PASS
Remark:
Required Observation
Result
(Pass/Fail)
Test Level
Test Equipment:
Magnetic Field Tester MAG100.1
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 20 of 24
8. PHOTOGRAPHS
8.1.Photos of Radiated Disturbance Test (In Anechoic Chamber)
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 21 of 24
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 22 of 24
8.2.Photos of Electrostatic Discharge Immunity Test
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 23 of 24
8.3.Photo of RF Strength Susceptibility Test
8.4.Photo of Magnetic Field Test
Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-J08621
Page 24 of 24