ETC Unison® 100-120V Rack Enclosure Unison DRd Series O r d e r i n g i n f o r m at i o n 100-120V - DRd Rack Enclosures Model Description DRd6-12-120 6 module rack enclosure (12 circuits) DRd12-24-120 12 module rack enclosure (24 circuits) DRd12-48-120* (2) 12 module rack enclosures (48 circuits) *In 48 channel configurations, (2) 12 module racks are cross-bussed using AX series main lug or main breaker enclosures. G e n e r a l I n f o r m at i o n 100-120V - Auxiliary Enclosures ETC’s Unison DRd Series Rack Enclosures are the workhorses behind the scenes, supporting two processor options and a variety of dimming, switching and option modules. DRd Rack Enclosures are trusted for their reliability and versatility Applications • Churches • Hotels • Convention Centers • Theatres • Schools • Restaurants Features • All-On – clearly marked switch allows for all loads to be turned on to full, without the need for a control processor • HighFault – protection from power spikes and surges with short circuit current ratings from 22,000 amps, up to 100,000 amps • Regulation – monitoring and adjustment of incoming line voltage with min and max scale voltages • Bypass – UL924-listed emergency lighting bypass input with load shedding • Hold Last Look – dimming engine holds the last output during any loss of control • QuickBoot – dimming engine boot time of less than 4 seconds • PowerStrip – solid copper bus that easily converts form 1-phase to 3-phase without additional parts • HiRes Dimming – support for 16 bit DMX and over 65,000 steps of dimming • Electronic Low Voltage Dimming – reverse phase dimming control when used with the ELV module Model Description AX6-MCB-1-150 Auxiliary rack with 150A Main Breaker for DRd6 -1ø, 3W AX6-MCB-3-100 Auxiliary Rack with 100A Main Breaker for DRd6 - 3ø, 4W AX12-MCB-1-300 Auxiliary Rack with 300A Main Breaker for DRd12 - 1ø, 4W AX12-MCB-3-200 Auxiliary Rack with 200A Main Breaker for DRd12 - 3ø, 4W AX12-ML-3-200 Auxiliary Rack with Main Lugs for DRd12 3ø, 4W AX12X-MCB-1-400 Auxiliary Rack with 400A Main Breaker for (2) DRd12 - 1ø, 3W AX12X-MCB-3-400 Auxiliary Rack with 400A Main Breaker for (2) DR12 - 3ø, 4W AX12X-ML-1-600 Auxiliary Rack with Main Lugs for (2) DR12 - 1ø, 3W AX12X-ML-3-400 Auxiliary Rack with Main Lugs for (2) DR12 - 3ø, 4W DRd Options and Accessories 1 of 4 Model Description DRd-FLO DRd 4-wire Fluorescent Option DRd-DALI DRd DALI Option DRd-PED DRd Floor Mount Pedestal ETC Unison® 100-120V Rack Enclosure Unison DRd Series sp e ci f ic a t i o n s Acc e ss o r i e s a n d Op t i o n s General • DRd rack enclosures available in two sizes. DRd6 with support for 6 modules and up to 12 circuits and DRd12 with up to 12 modules and 24 circuits. • Full 8 year Warranty Mechanical • Welded 18-gauge formed steel construction • Surface or floor stand mount • Hinged, lockable full-height door with electrostatic air filter • Fine-textured, scratch resistant, epoxy paint • Integral low voltage fan • Modular control electronics Electrical • 100-120 Volt, 3 phase systems – -- Field configurable for single-phase operation with no additional parts -- Available in 230 Volt CE, and 240 or 277 Volt UL configurations • Voltage tolerance ± 10% • Operating frequency: 50-60Hz. • DRd6/ DRd12 Rack Enclosure fault current protection: -- 22,000A Short Circuit Current Rating (SCCR) -- 100,000A SCCR when installed using AX Auxiliary Rack with Main Breaker • Main lugs accept maximum 350 MCM wire • Load terminals accept maximum #6 AWG wire • AX Racks equipped with breakers sized for maximum load capacity -- Lower rated trip plug options available • UL and cUL Listed Functional • High density dimming for incandescent, fluorescent, neon, cold cathode, electronic and magnetic low voltage transformer, load types • Ability to cross bus and control two rack enclosures using one control processor • Supports ETC Dimmer Doubling • 16 bit DMX input • Designed for reliable continuous operation Thermal • Ambient room temperature: 0-40°C / 32-104°F • Ambient humidity: 10-90% non-condensing Control Processors • SmartLink® Architectural Control Processor (S-ACP) • Paradigm™ Architectural Control Processor (P-ACP) Station power Options • SmartLink Station Power Module (S-SPM) -- Provides Echelon® LinkPower for up to 16 SmartLink stations -- Allows for up to 1640 feet (500 meters) of station bus wiring • Paradigm Station Power Module (P-SPM) -- Provides Echelon LinkPower for up to 32 Unison stations -- Provides 24V auxiliary power for interface and touchscreen stations -- Allows for up to 1640 feet (500 meters) of station bus wiring uNISON MODULES Model Description D15 Dual 1.8KW (120V) Dimmer Module D15E Dual 1.8KW (120V) High Rise-time Dimmer Module D15F Single 1.8KW (120V) 3-wire Dimmer Module R15 Dual 1.8KW (120V) Relay Module CC15 Dual 1.8KW (120V) Constant Current Module D20 Dual 2.4KW (120V) Dimmer Module D20E Dual 2.4KW (120V) High Rise-time Dimmer Module D20F Single 2.4KW (120V) 3-wire Dimmer Module R20 Dual 2.4KW (120V) Relay Module CC20 Dual 2.4KW (120V) Constant Current Module ELV10 Dual 1.2KW (120V) Electronic Low-Voltage Module Accessories • Unison RideThru Option (URTO) -- Short term power back-up of control electronics for at least 10 seconds -- Automatically engages when power is lost -- Recharges during normal power operation • Unison Battery Pack Option (UBPO) -- Long term power back-up of control electronics for at least 90 minutes -- Automatically engages when power is lost -- Recharges during normal power operation • 4-wire Fluorescent option (DRd-FLO)* -- 4-wire (0-10 Volt sink) ballast control -- Up to 24 outputs -- Up to 50 ballasts per output • DALI Ballast option (DRd-DALI)* -- Support for 24 loops of DALI control in broadcast mode -- Up to 63 ballasts per output -- External DALI power supply required (by others) • Unison DRd Pedestal (DRd-PED) -- Floor-mount pedestal for Unison DRd dimming enclosures *Option module required, either (1) DRd-DALI or (1) DRd-FLO may be used in each DRd enclosure 2 of 4 ETC Unison® 100-120V Rack Enclosure Unison DRd Series t y pic a l s y s t e m r is e r – sMARTL I N K C ONTROL To load circuits SmartLink Timeclock S-ATC To load circuits Unison DRd12 Unison DRd12 LinkConnect Belden 8471+(1) #14 LinkConnect Belden 8471+(1) #14 SmartLink button stations S10005 and S10010 LinkConnect Belden 8471+(1) #14 DMX Belden 9729 Link Power Link Power Fault+ Fault+ Fault- Fault- 1 Power DMX IN Error DMX Belden 9729 4 2 5 3 1 Power 6 7 8 9 recent and 0 help # nav thru 4 DMX IN Error 2 5 3 6 7 8 9 recent and 0 help # nav thru Optional DMX input Main input Main input t y pic a l s y s t e m r is e r – P a r a dig m C ONTROL To 3rd party serial device LinkConnect Belden 8471+(1) #14 Serial RS232 Belden 9729 Paradigm Touchscreen P-LCD ETC Net3 Belden 1583A PC for LightDesigner and other ETC software Paradigm Touchscreen P-LCD AuxPower (2) #16 AWG LinkConnect Belden 8471+(1) #14 DMX Belden 9729 Heritage Control Stations ETC Net3 Belden 1583A Aux Power Link Power Fault+ Fault- 1 Power DMX A DMX B Ethernet Error 2 abc 3 def 4 ghi 5 jkl 6 mno 7pqrs 8 tuv 9 wxyz recent and 0 help # nav thru Unison DR12 ETC Net3 Belden 1583A PoE Switch Remote Video Interface Net3 RVI ETC Net3 Belden 1583A ETC Net3 Belden 1583A Net3 Gateway N34G DMX Belden 9729 To DMX devices ETC Net3 Belden 1583A SmartSwitch SS24 ETC Net3 Belden 1583A Control Console ION Sensor+ SR48+ 3 of 4 ETC Unison® 100-120V Rack Enclosure Unison DRd Series physical Clearence above fan DRd12 AX Rack* 12.0” 304.8 mm DRd12 Clearence above fan AX Rack* 12.0” 304.8 mm DRd6 31.0” 787.4 mm 21.9” 556.3 mm Aux Power Aux Power Aux Power Link Power Link Power Link Power Fault+ Fault+ Fault- Fault- 2 abc 1 Power DMX A DMX B Ethernet Error Fault- Power 5 jkl 6 mno DMX A 7pqrs 8 tuv 9 wxyz Ethernet recent and 0 # nav thru help Fault+ 1 3 def 4 ghi DMX B Error 2 abc 3 def 1 Power 4 ghi 5 jkl 6 mno DMX A 7pqrs 8 tuv 9 wxyz Ethernet recent and 0 help # nav thru DMX B Error 2 abc 3 def 4 ghi 5 jkl 6 mno 7pqrs 8 tuv 9 wxyz recent and 0 help # nav thru 9.6” 243.8 mm 13.0” 330.2 mm 9.6” 243.8 mm 17.0” 431.8 mm 17.0” 431.8 mm 30.0” 762 mm 13.0” 330.2 mm 17.0” 431.8 mm 47.0” 1193.8 mm *Optional AX Shown Product Weights* Product Dimensions* Model Height inches mm Width inches mm model Depth inches mm weight shipping weight lbs kgs lbs kgs DRd6-12-120 21.9 557 17.0 432 9.60 244 DRd6-12-120 38 17.15 42 19.05 DRd12-24-120 31.0 787 17.0 432 9.60 244 DRd12-24-120 51 23.13 55 24.95 AX6 21.9 557 13.0 330 8.0 203 AX6-ML 23 10.43 28 12.70 AX12 31.0 787 13.0 330 8.0 203 AX6-MCB 28 12.52 35 15.87 AX12X 31.0 787 13.0 330 8.0 203 AX12-ML 28 12.70 35 15.88 AX12-MCB 33 14.97 40 18.14 AX12X-ML 33 14.97 40 18.14 AX12X-MCB 35 15.88 42 19.05 *Weights and dimensions typical Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736 London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000 Rome, IT • Via Ennio Quirino Visconti, 11, 00193 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486 Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00 Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325 Web • www.etcconnect.com • Copyright©2008 ETC. All Rights Reserved. All product information and specifications subject to change. PRELIMINARY Printed in USA 05/08 Unison® products protected by one or more of the following U.S. Patenten Numbers 5,323,088, 5,352,958 and 6,849,943; European Pateten Number 0603333; German Patent Number 69203609; US and International patents pending 4 of 4