DOULGERAKIS CONSULTING ENGINEERS, INC. To: DeKalb County, GA Board of Appeals 330 W Ponce de Leon Avenue, Suites 100-500 Decatur, GA 30030 404-371-2155 06/23/2015 RE: Application of Mr. Doug Bryant for Variances regarding a 0.20 acre tract of land located at 1574 N. Decatur Rd, Atlanta, GA 30307. (Parcel ID 18-053-02-001) Dear Board of Appeals: This firm represents the applicant, Mr. Doug Bryant, concerning the above-captioned variance application. The property at issue consists of a 0.20 acre tract of land located in unincorporated DeKalb County at the intersection of N Decatur Road and Oxford Road. The property is presently zoned C-1 and is located within the Emory Village Overlay District. The property currently is developed with a gas and service station which has been closed and decommissioned. The surrounding properties to the north, west and south are also zoned C-1 and located within the Emory Village Overlay District. The property to the north and east on the opposite side of Oxford Rd and the roundabout is part of the Emory University campus and is zoned O-I. The applicant has entered into contract to purchase the subject property and it is the applicant’s intent to renovate the existing structure and to repair/ repave the existing exterior paved areas. The present proposed use of the property is as an approximately 2000 SF wine store as described in the Emory Village Overlay District, however it is essential to the applicant that the property meet all the necessary requirements to permit a restaurant use as future tenant. The contract of sale for the property is conditional on the ability secure the necessary variances that would allow the renovated structure to be used at the applicants option as either a wine store or a restaurant. The following variances are requested: a. A special exception to reduce the required number of off street parking spaces for an approximately 2000 SF restaurant use from 16 spaces to 11 spaces. This would waive Sec. 27-728.11.14 for food service use requiring 8 spaces per 1,000 square feet of floor area to 5.5 spaces per 1000 square feet. b. A waiver to allow the use of small car “compact” spaces despite the total number of off-street parking being less than 20 spaces pursuant to Sec. 27-766 (b)(3). c. A waiver to allow parking in front of the building pursuant to Sec.27-728.11.4.(g)(6) and pursuant to the Emory Village Design Standard Guidelines Sec. II.B.2. d. A waiver to reduce the minimum one way drive aisle for a private alley from 12 ft to 10 ft per Sec. 14195(b)(1). e. A waiver to eliminate the required 10 ft planting strip between off street parking and the public sidewalk pursuant to Sec. 27-766(4). f. A waiver to eliminate the 5 ft wide landscaping buffer area between the parking lot and the build to line pursuant to the Emory Village Design Standard Guidelines Sec. II.B.2. All of the above requested variances are required due to the undue hardships caused by the narrow size and shape of the property and by the locations of the existing structure and driveway entrances/exits. The requests above are the minimum variances necessary to afford relief of the zoning regulations for the proposed use. Attached to this letter for the consideration of this Board are a survey of the property, a proposed conceptual site plan, proposed architectural elevations, a proposed conceptual landscaping plan, current photos of the property and a historical photo of the property. Sincerely, Emmanuel Doulgerakis, P.E. & MSCE Page 1 of 1 400 Abbey Court, Alpharetta, GA 30004 · (770) 753-9800 · Fax (770) 753-9810 SITE DATA Zoning............................ C-1 w/ Emory Village Overlay Setbacks: Front...................... 20 ft Side........................ 0 ft Rear........................ 0 ft Parcel Area........................ 0.20 AC Total Parking Provided........... 11 spaces Standard.................... 9 spaces Handicap.................... 1 space Small Car (Compact)...... 1 space Lot Coverage: Existing...................... 100% Proposed.................... 98% EXISTING DRIVEWAY EXISTING PLANTER BOXES PROPOSED DUMPSTER LOACTION W/ SCREENING NOTE: VARIANCES REQUIRED FOR PARKING SPACES IN FRONT OF BUILDING, ELIMINATION OF PARKING BUFFER STRIP, REDUCTION OF MINIMUM ONE WAY DRIVE AISLE WIDTH, AND ALLOWANCE OF COMPACT PARKING SPACES. VARIANCE REQ'D TO REDUCE MIN ONE WAY AISLE WIDTH TO 10 FT EXISTING WALL EXISTING BUILDING EXIST. RAISED CURB DELIVERIES EXIST. CONC. SIDEWALK EMERGENCY EXIT RAISED PLANTER BOX (TYP) EXISTING BUILDING INTOWN BEVERAGE APPROX. 2000 SF N68° 24' 15.8"E 5.62' EXISTING BUILDING N HANDICAP RAMP STEPS "E .7 8 2 0' ' 0 7.74 ° 51 3 P. PRO EXISTING BUILDING OWNER and DEVELOPER WHEEL STOP MAIN ENTRANCE PARALLEL PARKING SPACE S70° 15' 40.9"W 2.64' LDG B F EO EDG NO F CA PY EXISTING SIDEWALK GE O D E T. EXIS PROP. PAVERS ING E D L I BU K LIN BAC SET RAISED PLANTER BOX EXIST. STREET TREE PROP. PAVERS EXISTNG SIGN EXISTING DRIVEWAY EXISTING DRIVEWAY EXISTING BIKE RACK (3 SPACES) REVISION EXISTING WALL NO. DATE EXIST. STREET TREE SCALE: DATE: R 0 10' 20' 30' 1" = 10' 06-23-15 JOB. NO. GRAPHIC SCALE : 1" = 10' Know what's below. E n g i n e e r i n g Co n t a c t Call before you dig. SHEET. 1523 1 of 1 J. R Y A N D U F F E Y ARCHITECT, INC 1 8 E a s t A n d r e w s D r i v e A t l a n t a, G A 3 0 3 0 5 T e l e p h o n e : 4 0 4 . 8 0 8 . 7 8 8 4 F a c s i m i l e : 4 0 4 . 8 1 6 . 2 3 2 6 E m a i l : ryan@jryanduffey.com RENOVATIONS TO THE STANDARD OIL GAS STATION 1574 N. DECATUR ROAD ATLANTA, GA 30307 Copyright © 2012 J. Ryan Duffey Architect, Inc All rights reserved. This drawing is the property of J. Ryan Duffey Architect, Inc and is not to be reproduced or copied in whole or in part, the dimension of which are 22" x 34". It is only to be used for the project and site specifically identified herein and is not to be used on any other project without written permission from the Architect. The Contractor is responsible for verifying all field measurements, quantities, dimensions and related field construction criteria. Half-Size Plot Note to Contractor: Any discrepancies, inconsistencies or ambiguities found between the drawings, specifications & site conditions shall be immediately reported to the Architect in writing. The Architect will promptly correct the same in writing. Work done by the contractor after discovery of such discrepancies, inconsistencies or ambiguities shall be done at the contractor's risk. Print Record 01 MAY 2014 CLIENT REVIEW Revisions Date: Project #: 28 APR 2014 Drawn By: J.R.D. Checked By: J.R.D. 15003 AS - BUILT PLANS AB1.1 R eleased for Construction Not Released for Construction