Volume 8 • Number 1 • 2001 Amino Acid # Amino Acid # Amino Acid # = Semi-Permissive = Permissive G20 R388 Y100 R255 Figure 4. The location of the 19-amino acid insertion into eight independent β-galactosidase insertion derivatives. The designated amino acid is immediately N-terminal to the point of insertion. The domain structure of β-galactosidase is adapted from Jacobson et al., (1994) Nature 369:761. = Non-permissive D671 N345 L631 P703 EZ::TN™ In-Frame Linker Insertion Kit EZI04KN Domain 1 αComplementation Region 1 100 Domain 2 200 300 Domain 3 400 500 Domain 4 600 700 TransforMax™ EC100™ Electrocompetent E. coli Domain 5 800 900 10 Reactions 1000 β-galactosidase Highest efficiency electrocompetent cells available. See center insert for more information. EC10005 5 X 100 µl (10 electroporations) EC10010 10 X 100 µl (20 electroporations) Finish your DNA Sequencing Project Complete Difficult Regions with SequiTherm EXCEL™ II DNA Sequencing Kits Sequence through hairpin loops, regions of high GC or AT content, areas of interstrand reannealing, and inverted or direct repeats. Using end-labeled primers, SequiTherm EXCEL II DNA Sequencing Kits provide complete, clear sequencing data when all other methods fail. “I know of no other sequencing method that resolves GC compressions better than SequiTherm EXCEL™ II.” - Glenn Dawes, Affymax Research Institute, The Scientist, Vol.12, #6, 1998, pg. 13 SequiTherm EXCEL II resolved a “2-year-old puzzle” due to “an unreadable hairpin loop” for the Washington University genome center. - Science, Vol. 280, 8 May 1998, pg. 816 G A T C Benefits SequiTherm EXCEL™ II DNA Sequencing Kit - LC For 25-41 cm gels on LI-COR® Sequencers • Complete work on most any difficult gap to finish your sequencing project. • High flexibility - you can perform both cycle and isothermal sequencing with one kit. • Kits compatible with LI-COR® and ALF™ DNA Sequencers (both dyeprimer and internal label) and with ABI™ automated sequencers (dye-primer). SE9101LC Figure. Sequencing through a GC-rich trinucleotide repeat. Supercoiled plasmid template containing (CGG)23 was sequenced using the SequiTherm EXCEL II isothermal sequencing protocol. (100 Sequences) SequiTherm EXCEL™ II DNA Sequencing Kit - LC For 66 cm gels on LI-COR® Sequencers SE9202LC (100 Sequences) SequiTherm EXCEL™ II Long-Read™ DNA Sequencing Kit - ALF™ For ALF DNA Sequencers SE8301A (100 Sequences) SequiTherm EXCEL™ II DNA Sequencing Kit • Reduced background signal. (for manual cycle and non-cycle sequencing) SEM79020 20 Sequences SEM79050 50 Sequences SEM79100 100 Sequences www.epicentre.com 3