Phantoms • END-TO-END STEREOTACTIC QA Perform image transfer QA, dosimetry and machine QA within the exact coordinate system of commercially available stereotactic head frames and frameless mask systems •PHYSICS TOOLS AT YOUR FINGERTIPS The Lucy 3D QA Phantom minimizes clinically relevant errors by quantifying system variances in the imaging chain to within 0.1mm. Increase your confidence in your system to correctly image known volumes, distances and geometries. Confirm that CT/MRI/Angioscans and image fusion are accurately recreated within the TPS, assuring precise target dose delivery •SRS PATIENT DOSIMETRY QA Obtain absolute, relative and point dose dosimetry QA measurements at isocenter and at exact positions off Elekta Fraxion™ Stereotactic Frame Interface for Fraxion systems isocenter, using your current ion chambers, film, diodes, gels, MOSFETs and TLDs •RADIATION ALIGNMENT MACHINE QA Assess optical and geometric isocenter, laser alignment, BrainLAB Stereotactic Frame Interface and non-invasive Mask Systems indexed table positioning alignment and positioning coordinates for a comprehensive evaluation of geometric accuracy. Precisely determine CBCT and MV/kV isocenter alignment. •LOCKS INTO SRS FRAMES Leksell Gamma Knife® Stereotactic Frame Interface Quickly and precisely position the Lucy 3D QA Phantom within the manufacturer’s exact coordinate system using the Stereotactic Frame Interface, available for all commercial SRS systems. Works for invasive and non-invasive systems. Varian / Radionics™ / CRW/BRW Stereotactic Frame Interface Phantoms Features • Make QA setup easy by locking the Lucy 3D QA Phantom to your exact SRS coordinate system • Effectively evaluates six degrees of freedom positioning systems in 3D space with convenient image markers • Commission your system quickly by using the Lucy 3D QA Phantom to confirm specification upon delivery of equipment • Evaluate manufacturer’s automatic patient positioning systems with film, ion chambers, diodes, gels, MOSFETs and TLDs • Use as a QA tool as described in the performance validation references 1,2,3,4,5 and in AAPM Task Group reports including TG-142 • Check cone beam CT performance in 3D space • Ideally suited for QC and dosimetry measurements with framed and frameless SRS systems • Evaluate CT/MRI/Angiofusion at 20 points in 3D space Configurations Lucy 3D QA Phantom Lucy MRI Imaging QA Accessory Package • Spherical Lucite Phantom • MRI Marker Cylinders, set of four • Precision Leveling and Rotational Alignment Base • MRI Volume Insert with three known geometries Stereotactic Frame Interfaces • MRI Signal Generator • Elekta Fraxion Radiation Alignment Pointers • BrainLAB • Includes 5 mm tungsten sphere tip and 3 mm aluminum sphere tip • Leksell Gamma Knife • Varian and Radionics CRW/BRW frame • Tomotherapy Hi-Art System • Precision Leveling and Rotational Alignment Base for frameless systems and extracranial work • Automate Winston-Lutz test with the Lucy 3D QA Phantom and PIPSpro Software using a filmless procedure Accessories • IGRT kV and X-Ray Angiography Marker Cylinders, set of four Lucy Dosimetry QA Accessory Package • Dosimetry Film Cassette for fourteen 2.5 x 2.5 inch films • Dosimetry Insert for small volume ion chamber of your choice • Other accessories are available for many ion chambers, TLD dosimetry, diode detectors, MOSFET detectors and MRI compatible bases for phantom positioning • Dosimetry Film Cassette for three 3 x 3 inch films • Target/Treatment Verification Film Cassette Dosimetry Instruments Lucy CT Imaging QA Accessory Package • MAX 4000 Electrometer • CT Marker Cylinders, set of four • Exradin A16 MicroChamber • CT Electron Density Insert • Exradin A14SL MicroChamber • CT Volume Insert with three known geometries • CT Grid Insert for spatial distortion Leksell Gamma Knife® is a registered trademark of Elekta Instruments, Inc. CyberKnife® is a registered trademark of Accuray Incorporated. TomoTherapy Hi-Art System® is a trademark of TomoTherapy, Inc. Specifications subject to change without notice. performance validation 1. R. Ramasesham, M. Heydarian, “Comprehensive quality assurance for stereotactic radiosurgery treatments”, Phys. Med. Biol. 48(2003) N119-N205. 2. R. Ramani, et.al., “A QA phantom for dynamic stereotactic radiosurgery: Quantitative measurements”, Med. Phys. 22(8), August 1995. 3. R. Ramani, et.al., “The use of Radiochromic film in treatment verification of dynamic stereotactic radiosurgery”, Med. Phys. 21(3), 1994. 4. AAPM Radiation Therapy Committee TG53: “Quality assurance for clinical radiotherapy treatment planning”, Med. Phys. 25(10), October 1998. 5. AAPM Radiation Therapy Committee TG66: “Quality assurance for computed-tomography simulators and the computed-tomography-simulation process”, Med. Phys. 30(10), October 2003 3120 Deming Way Middleton WI 53562-1461 USA 800-261-4446 . ph 608-831-0025 . fax 608-831-2202 www.standardimaging.com © 2010 Standard Imaging, Inc. 1284-21, 9/10