Thermal Heads for Power and Single-Shot Energy – mW to KW, mJ to 300J The highest damage threshold in the industry Models for 1500W 5000W, 8000W and 20KW for high power laser measurement LP coating that can withstand up to 6KW/cm2 at the maximum rated head power Energy damage threshold up to 250J/cm2 EMI rejection Single pulse energy measurement up to 200 joules Sensitive meters to measure power down to 40 W and energy to 7 J www.ophiropt.com 32 Thermal Surface Absorbing Heads Laser Power & Energy (For pulses shorter than 100µs see volume absorber section on page 46) 3A CW & Pulsed Measurements 60 W-3W 15 J-2J Recommended Use: Very low power and energy lasers Special Features: Very sensitive, low noise, fast response Heads BB pyro 0.19 - 20µm Ø9.6mm 3W / 300mW / 30mW / 3mW / 300µW 200W/cm2 2µW 5 - 20µW a ±3% 1.5s 0.3J/cm2 for 10ns pulses ±1.5% 2J / 200mJ / 20mJ / 2mJ / 200µJ 15µJ ±2% ±2µJ See drawing Convection 48 30 Ø70 Ø9.5 19 Ø23 97-143 ADJUSTABLE 30o 100 75 Note a: Depending on typical room airflow and temperature variations Displays Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Thermal drift (30 min): Power Accuracy: Response Time with Display (0 - 95%): Maximum Energy Density: Linearity with Power: Energy Scales: Energy Threshold: Linearity with energy: Dimensions: Cooling: 3A 3A-FS CW & Pulsed Measurements 40 W-3W 7 J-2J Notes a: For measurement beyond 2.5µm and up to 20µm, window should be removed. Noise and drift will be higher b: Depending on typical room airflow and temperature variations 3A-FS 34 30 Ø9.5 Ø70 19 Ø25 Ø23 30˚ 97 - 143 ADJUSTABLE 75 100 Ordering Information Item 3A 3A-FS Fiber Adapters Description 3 Watt power/energy meter for low power lasers 3 Watt power/energy meter for low power lasers with removable fused silica window See page 55 for ordering information www.ophiropt.com 33 Integrated Systems Broadband, 0.19 - 2.5µm a Ø9.6mm 3W / 300mW / 30mW / 3mW / 300µW 200W/cm2 2µW 2 - 10µW b ±3% 1.5s 0.3J/cm2 for 10ns pulses ±1.5% 2J / 200mJ / 20mJ / 2mJ / 200µJ 7µJ ±2% ±1.5µJ See drawing Convection Ophir P/N 1Z02621 1Z02628 OEM Products Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Thermal drift (30 min): Power Accuracy: Response Time with Display (0 - 95%): Maximum Energy Density: Linearity with Power: Energy Scales: Energy Threshold: Linearity with energy: Dimensions: Cooling: Beam Profile Wavelength Recommended Use: Very low power and energy lasers Special Features: Removable fused silica window Very sensitive, low noise, fast response. Paricularly suitable for thermally unstable environments 10A CW & Pulsed Measurements 20mW-10W 6mJ-2J Recommended Use: General, powers to 10W Special Features: Compact, fast response Broadband, 0.19 - 20µm Ø16mm 10W / 5W / 0.5W 30KW/cm2 1mW ±3% 0.8s ±1% 2J / 200mJ 6mJ Convection 33.5 Ø65 Ø16 Distance from front surface to absorber 11.3mm ˚ 10 75 Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0 - 95%): Linearity with Power: Energy Scales: Energy Threshold: Cooling: 10A ADJUSTABLE 92 - 127 75 100 12A CW & Pulsed Measurements 2mW-12W 1mJ-30J Recommended Use: Very low to low power and energy lasers Special Features: Very wide dynamic range, low noise and drift Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Thermal drift (30 min): Power Accuracy: Response Time with Display (0 - 95%): Maximum Energy Density: Linearity with Power: Energy Scales: Energy Threshold: Linearity with energy: Dimensions: Cooling: Broadband, 0.19 - 20µm Ø16mm 12W / 2W / 200mW / 20mW / 2mW 25KW/cm2 50µW 40-150µW a ±3% 2.5s 0.3J/cm2 for 10ns pulses ±1.5% 30J / 3J / 200mJ / 300mJ / 30mJ b 1mJ ±1.5% ±50µJ See drawing Convection 12A 38 Ø80 7 Ø16 45˚ ADJUSTABLE 19 102-134 44 ADJUSTABLE 107 - 150 43 ø85 Notes: a. Depending on typical room airflow and temperature variations. b. For the 30mJ energy scale measurements it is recommended to use the attached snout or to protect the head from direct air flow. 100 75 75 100 Ordering Information Item 10A-V3 12A Fiber adapters Description 10 Watt power/energy meter for low power lasers 12 Watt power/energy meter for low power lasers See page 55 for ordering information www.ophiropt.com 34 Ophir P/N 1Z02637 1Z02638 30A Recommended Use: General purpose powers to 30W Special Features: Fast response, wide dynamic range 30A Broadband, 0.19 - 20µm Ø17.5mm 30W / 5W a 25KW / cm2 1mW ±3% 0.8s ±1% 30J / 3J b 6mJ Convection 44 43 ø85 Ø17.5 Heads Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0 - 95%): Linearity with Power: Energy Scales: Energy Threshold: Cooling: Laser Power & Energy CW & Single Pulse Measurements 20mW-30W 6mJ-30J Notes: a. Use model 30(150)A-HE / HE1/HL for higher energies. b. The maximum energy density even for long pulses is limited to 2J / cm2. ADJUSTABLE 102-134 21.5 45o 75 Displays 100 L30A CW & Single Pulse Measurements 80mW-30W 20mJ-30J Broadband absorber 0.19 - 20µm Ø29mm 30W/3W 25KW/cm2 4mW ±3% 1.5s ±1% 30J/3J/300mJ 20mJ Convection L30A 44 43 Ø29 Ø85 ADJUSTABLE 102-134 100 75 Integrated Systems Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0-95%): Linearity with Power: Energy Scales: Energy Threshold: Cooling: Beam Profile Wavelength Recommended Use: Divergent beams, large aperture Special Features: 29 mm aperture, 30 watts Item 30A-V1 L-30A-V1 Fiber adapters www.ophiropt.com Description 30 Watt power/energy meter Large aperture 30 Watt power/energy meter See page 55 for ordering information 35 Ophir P/N 1Z02604 1Z02603 OEM Products Ordering Information L30A-10MM CW & Single Pulse Measurements 80mW-30W 20mJ-60J Recommended Use: Tight spaces, photolithography exposure Special Features: Low profile – 10mm thick, 26mm aperture Absorber: Aperture: Digital Power Scales: Maximum Power: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0-95%): Linearity with Power: Energy Scales: Energy Threshold Repeatability of Energy: Max Width of Pulse train Cooling: Broadband absorber 0.15 - 20µm Ø26mm 30W/3W 4W free standing, 30W heat sinked 25KW/cm2 4mW ±3% 1.5s ±1% 60J/20J/2J/200mJ 20mJ 0.5% 4s for measuring accumulated energy Convection, conduction L30A-10MM 10 Ø75 Ø26 55o ADJUSTABLE 100-145 100 75 L50A CW & Single Pulse Measurements 80mW-50W 20mJ-100J Recommended Use: General purpose to 50W Special Features: Large aperture, convection cooled Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0-95%): Linearity with Power: Energy Scales: Energy Threshold Cooling: Broadband, 0.19 - 20µm Ø29mm 50W/5W 20KW/cm2 4mW ±3% 1.5s ±1% 100J / 30J / 3J / 300mJ 20mJ Convection L50A Ø100 Ø29 47 18.5 ADJUSTABLE 110 - 135 100 75 Ordering Information Item L30A-10MM L50A Fiber adapters www.ophiropt.com Description Large aperture 10mm thick 30 Watt power/energy meter 50 Watt power meter for general use See page 55 for ordering information 36 Ophir P/N 1Z02273 1Z02606 30(150)A Laser Power & Energy CW & Average Power Measurements 60mW-150W 20mJ-100J Recommended Use: Short-term measurement to 150 watts Special Features: Compact, convection cooled 30(150)A Broadband, 0.19 - 20µm Ø17mm 150W/30W a 20KW/cm2 3mW ±3% 1.2s ±1% 100J/30J/3J 20mJ Convection 44 43 Ø85 Ø17 Heads Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0-95%): Linearity with Power: Energy Scales: Energy Threshold Cooling: ADJUSTABLE 102-134 Note a: Maximum continuous power is 30 Watts. Can be used intermittently to 150 watts. 75 Displays 100 L30(150)A-LP CW & Pulsed Measurements 50mW-150W 80mJ-300J Energy Threshold Cooling: LP 0.4 - 1.5, 10.6µm Ø29mm 150W/30W/3W a 30W continuous, 150W intermittent 3mW ±3% 1.5s ±1% 300J/30J/3J 10ns 0.1J/cm2 2ms 50J/cm2 10ms 150J/cm2 25mJ Convection Beam Profile Wavelength Absorber: Aperture: Digital Power Scales: Maximum Average Power: Power Noise Level: Power Accuracy: Response Time with Display (0-95%): Linearity with Power: Energy Scales: Maximum Energy Density J/cm2 L30(150)A-LP 44 43 Ø29 Ø85 ADJUSTABLE 102-134 Note a: Maximum continuous power is 30 Watts. Can be used intermittently to 150 watts. 100 75 Integrated Systems Recommended Use: Long pulsed lasers Special Features: High damage threshold for long pulses and CW Item 30(150)A-V1 L30(150)A-LP Fiber adapters www.ophiropt.com Description 30/150 Watt power/energy meter Power meter for high energy pulses >1ms, 30W continuous, 150W intermittent See page 55 for ordering information 37 Ophir P/N 1Z02608 1Z02636 OEM Products Ordering Information L40(150)A CW & Average Power Measurements 200mW-150W 80mJ-200J Recommended Use: Large beams, low profile, single shot energy Special Features: Large aperture, slim profile Absorber: Aperture: Digital Power Scales: Maximum Power: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0-95%): Linearity with Power: Energy Scales: Energy Threshold Cooling: L40(150)A Broadband, 0.19 - 20µm Ø50mm 150W/20W 35W continuous, 150W intermittent 20KW/cm2 15mW ±3% 2.5s ±1% 200J/30J/3J 80mJ Convection 90 (2x) M3 Mounting Threads 33 72 17 Ø50 ADJUSTABLE 107 - 152 75 100 L50(150)A CW & Pulsed Measurements 200mW-150W 80mJ-200J Recommended Use: Large aperture lasers Special Features: Convection cooled, up to 50W CW, 150W intermittent Absorber: Aperture: Digital Power Scales: Maximum Average Power: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0-95%): Linearity with Power: Energy Scales: Energy Threshold Cooling: L50(150)A Broadband, 0.19 - 20µm Ø50mm 150W/20W 50W continuous, 150W intermittent 20KW/cm2 6mW ±3% 2.5s ±1% 200J/30J/3J 80mJ Convection 38.5 (5x) 3.5 (6x) 2.5 100 (2x) M3 Mounting Threads 100 16 Ø50 ADJUSTABLE 112 - 158 75 100 Ordering Information Item L40(150)A-V2 L50(150)A Fiber adapters www.ophiropt.com Description Large aperture power/energy meter, 35W continuous, 150W intermittent Large aperture power/energy meter, 50 W continuous, 150W intermittent See page 55 for ordering information 38 Ophir P/N 1Z02626 1Z02633 F150A Recommended Use: High power surgical lasers, broadband Special Features: Fan cooled F150A Broadband, 0.19 - 20µm Ø17.5mm 150W/30W 15KW/cm2 3mW ±3% 1.2s ±1% 100J/30J/3J 20mJ Fan 115 118 89 45 Ø50 Heads Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0-95%): Linearity with Power: Energy Scales: Energy Threshold Cooling: Laser Power & Energy CW & Average Power Measurements 60mW-150W 20mJ-100J 44.5 13 89 ADJUSTABLE 106-152 100 Displays 75 FL250A CW & Average Power Measurements 200mW-250W 50mJ-200J Recommended Use: Surgical lasers, large beams Special Features: Fan cooled, large aperture Broadband, 0.19 - 20µm Ø50mm 250W/30W 250W 10KW/cm2 10mW ±3% 2.5s ±1% 300J/30J/3J 50mJ Fan 115 118 89 45 Ø50 44.5 13 89 ADJUSTABLE 106-152 100 75 Integrated Systems Absorber: Aperture: Digital Power Scales: Maximum Power: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0-95%): Linearity with Power: Energy Scales: Energy Threshold Cooling: Beam Profile Wavelength FL250A www.ophiropt.com Description Fan cooled 150W power/energy meter Fan cooled 150W power/energy meter with electrical calibration option Large aperture fan cooled 250 Watt power/energy meter See page 55 for ordering information 39 Ophir P/N 1Z02163 1Z02164 1Z02605 OEM Products Ordering Information Item F150A F150A-CAL FL250A-V1 Fiber adapters FL300A CW & Average Power Measurements 200mW-300W 50mJ-300J Recommended Use: General purpose to 300W Special Features: Fan cooled FL300A Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0 - 95%): Linearity with Power: Energy Scales: Energy Threshold: Surface Uniformaty: Cooling: Broadband, 0.19-20µm Ø50mm 300W/30W 8KW/cm2 10mW ±3% 2.5s ±1% 300J/30J/3J 50mJ ±2% over central 70% of surface Fan 115 118 89 45 Ø50 44.5 13 89 ADJUSTABLE 106-152 100 75 FL300A-LP CW & Average Power Measurements 200mW-300W 50mJ-300J Recommended Use: High power and long pulse YAG and CO2 lasers Special Features: High power density and high pulse energy density Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0 - 95%): Linearity with Power: Energy Scales: Energy Threshold: Maximum Energy Density: Surface Uniformaty: Cooling: LP 0.4-1.5, 10.6µm Ø50mm 300W/30W 10KW/cm2 10mW ±3% 2.5s ±1% 300J/30J/3J 50mJ 0.1J/cm2 10ns 20J/cm2 0.5ms 120J/cm2 5ms ±2% over central 70% of surface Fan FL300A-LP 115 118 89 45 Ø50 44.5 13 89 ADJUSTABLE 106-152 100 75 Ordering Information Item FL300A FL300A-LP www.ophiropt.com Description Large aperture fan cooled 300W power/energy meter Large aperture 300W power/energy meter with damage resistant LP coating 40 Ophir P/N 1Z02627 1Z02635 L250W Laser Power & Energy CW & Single Pulse Measurements 4W-250W 200mJ-200J Recommended Use: Tight spaces Special Features: Water cooled, very thin design – 20mm thick Broadband, 0.19-20µm Ø50mm 250W / 30W 250W 10KW / cm2 200mW ±3% 2.5s ±2% 200J/ 30J/ 3J 200mJ Water – 1.0 liter/minute, (minimum) Water temperature range 18-30oC Water temperature rate of change <1oC/min. L250W CABLE WATER CONNECTION 6.5 20 10 60 90 15 Heads Absorber: Aperture: Digital Power Scales: Maximum Average Power: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0 - 95%): Linearity with Power: Energy Scales: Energy Threshold: Cooling: Ø50 6.5 90 1/4-20 BSW 6 DEEP 1/8-27 NPT THREAD FOR WATER CONNECTION Displays WATER CONNECTOR FOR Ø1/4” PLASTIC HOSE 1000W CW & Average Power Measurements 5W-1000W 300mJ-300J 1000W 35 Ø34 1 / 8” NPT 21.5 THREAD SIZE Ø100 9 45˚ 30˚ ADJUSTABLE 112-158 17.5 1 / 4” BSW THREAD FOR ROD QUICK CONNECT FITTING FOR Ø3 / 8” PLASTIC HOSE 100 75 Ordering Information Item L250W 1000W-V1 www.ophiropt.com Description Thin profile, water cooled 250W power/energy meter 1000 Watt power/energy meter 41 Integrated Systems Broadband, 0.19 - 20µm Ø34mm 1000W / 200W 6KW / cm2 0.2W ±3% 2.5s ±2% 300J / 30J 300mJ ±2.5% Water – 1.8 liter / minute (minimum) Water temperature range 18-30oC Water temperature rate of change <1oC/min. Ophir P/N 1Z02688 1Z02634 OEM Products Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0 - 95%): Linearity with Power: Energy Scales: Energy Threshold: Surface Uniformity: Cooling: Beam Profile Wavelength Recommended Use: High power CO2, Nd YAG and Diode lasers Special Features: High power, fast response, compact L1500W / L1500W-LP CW & Average Power Measurements 20W-1500W 500mJ-200J Recommended Use: High power and long pulse YAG and CO2 and Diode lasers Special Features: High power and energy density, large aperture Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Response Time with Display (0 - 95%): Linearity with Power: Energy Scales: Energy Threshold: Maximum Energy Density Cooling: Broadband 0.19-20µm LP 0.19-1.5, 10.6µm Ø50mm 1500W / 150W BB-5KW/cm2, LP-6KW/cm2 0.7W ±5% 2.7s ±2% 200J / 20J 500mJ pulse width BB LP 10ns 0.3J/cm2 0.1J/cm2 0.5ms 5J/cm2 20J/cm2 5ms 20J/cm2 120J/cm2 Water – 2.5 liter / minute, (minimum) Water temperature range 18-30oC Water temperature rate of change <1˚C/min. L1500W/L1500W-LP 40 Ø120 Ø50 1 / 8” NPT THREAD SIZE 22 15o 6.5 30o ADJUSTABLE 125-165 QUICK CONNECT FITTING FOR Ø3 / 8” PLASTIC HOSE 100 75 Ordering Information Item L1500W L1500W-LP www.ophiropt.com Description Water cooled 1500W power/energy meter Large aperture 1500W power/energy meter with damage resistant LP coating 42 Ophir P/N 1Z02660 1Z02082 5000W / 5000W-LP Laser Power & Energy CW Power 100W-5000W Recommended Use: High power and long pulse YAG, CO2 and Diode lasers Special Features: High power density and large pulse energy density. Diode LP type – Highest damage threshold 5000W/5000W-LP Absorber: Broadband 0.19-20µma LP 0.19-1.5, 10.6µma Aperture: Ø50mm Digital Power Scales: 5000W / 500W Maximum Ave. Power Density: BB - 3KW / cm2 LP - 4KW / cm2 Power Noise Level: 1W Power Accuracy: ±5% Response Time with Display (0 - 95%): 3s Linearity with Power: ±2% Energy Scales: N.A. Cooling: Water – 4.5 liter / minute, (minimum) Water temperature range 18-30oC Water temperature rate of change <1oC/min. 52 Ø146 1 / 8” NPT THREAD SIZE Ø50 30o 30o 30o ADJUSTABLE 135-180 34.5 6.5 QUICK CONNECT FITTING FOR Ø3/8” PLASTIC HOSE 100 75 Displays Note a: Head is calibrated for YAG, CO2 and Diode lasers. Heads 14.5 10K-W CW & Pulsed Measurements 200W-10,000W Recommended Use: Very High Powers and power densities Special Features: Withstands up to 10KW/cm2 at 10,000W 10K-W 71 Ø146 Ø45 7 30˚ CABLE 55.5 18.5 30˚ 30˚ ADJUSTABLE 135-180 75 1/8” NPT THREAD SIZE QUICK CONNECT FITTING FOR Ø3/8” PLASTIC HOSE Integrated Systems Broadband type for 0.8-1.1µm and 10.6µm. Patent pending method for beam intensity reduction Aperture: Ø45mm Digital Power Scales: 10KW / 1KW Beam Maximum Ave. Power Max Power Max Energy Density Diameter Density 1ms pulse w 3ms p.w. 10ms p.w. and energy Density: <15mm 60J/cm2 150J/cm2 10KW/cm2 30J/cm2 15-20mm 7KW/cm2 20J/cm2 40J/cm2 100J/cm2 20-40mm 5KW/cm2 15J/cm2 30J/cm2 70J/cm2 40-45mm 4KW/cm2 12J/cm2 25J/cm2 60J/cm2 2W Power Noise Level: ±5% Power Accuracy: Response Timewith Display (0 - 95%): <3s ±2% Linearity with Power: N.A. Energy Scales: ±2% Beam Size Dependence: ±5 degrees Maximum incidence Angle: Water – 9 liter / minute, (minimum) Cooling: Water temperature range 18-25oC Water temperature rate of change <1oC/min. Beam Profile Wavelength Absorber: 100 Item 5000W 5000W-LP 10K-W-V1 Description Water cooled 5000W power meter 5000W power/energy meter with damage resistant LP coating Water cooled 10,000W power meter www.ophiropt.com 43 Ophir P/N 1Z02119 1Z02255 1Z02645 OEM Products Ordering Information Comet Laser Power Probes CW power: Comet 10K, 10K-HD – 200W to 10KW, Comet 1K – 20W to 1KW Ophir now offers the simple to use, economical but also highly accurate Comet laser power probe. It operates by measuring the heat rise from a 10 second exposure to a laser beam. The Comet has a sophisticated algorithm to take into account the heat loss due to the Comet temperature so that it gives accurate readings even if it is hot before the measurement. This allows you to take several measurements before cooling the probe with water. Along with the Comet 10K for industrial lasers which measures mainly from 1KW to 10KW, Ophir offers a smaller Comet 1K for measuring from ~20W up to 1KW. Recommended Use: Comet 10K, 10K-HD – Industrial lasers, Comet 1K – quick power check of low-med power lasers Special Features: Accurate, simple to use and inexpensive Ø55 SMART KEYS Ø50 MAX. BEAM DIAMETER SMART KEYS MENU 43 39 25 Ø110 "ON/READY/OFF" BUTTON BUTTON “ON/READY/OFF” 43 95 LASER ABSORBER Model Power measurement range: Spectral range: Absolute calibation accuracy at calibrated wavelengths: Repeatability: Linearity with power: Number of readings before probe must be cooled (for 25degC starting temp.) Comet 10K 200W to 10,000W CO2, YAG & diode ±5% 295 12.5 25 SMART KEYS 39 Ø90 350 39 14 26.5 145 100 145 345 12.5 50 87 MENU ON/READY/OFF 100 53 ON/READY/OFF 145 Comet 10K HD 200W to 10,000W CO2 ±5% 43 Ø100 LASER ABSORBER BUTTON “ON/READY/OFF” Comet 1K 20W to 1000W 0.2 - 20µm ±5% ±1% for same initial temperature ±1% for same initial temperature ±1% for same initial temperature ±2% ±1W from 20W to 1KW ±2% from 1KW to 10KW ±2% from 1KW to 10KW 4 4 100W 4 1KW 1KW 3 3 300W 3 3KW 3KW 2 2 400W 2 4KW 4KW 1 1 1KW 1 10KW 10KW Dimensions: Absorber: Ø50mm diameter x 25mm Absorber: Ø100mm diameter x 50mm Absorber: Ø110mm diameter x 87mm thick thick thick. Max beam size 55mm Length: 340mm Length: 295mm Length: 340mm Standard Model Damage Threshold for power: a 1K Model Power Beam diameter <40mm Beam diameter >40mm Power 3500W/cm2 7KW/cm2 10KW/cm2 1KW 100W 10KW/cm2 2800W/cm2 6KW/cm2 8KW/cm2 2KW 200W 10KW/cm2 2500W/cm2 5KW/cm2 6KW/cm2 3KW 300W 8KW/cm2 1500W/cm2 3KW/cm2 5KW/cm2 5KW 500W 6KW/cm2 1000W/cm2 2KW/cm2 4KW/cm2 10KW 1KW 4KW/cm2 Damage threshold for <100ns 0.3J/cm2 0.3J/cm2 1J/cm2 energy/pulse width: 1J/cm2 1J/cm2 10µs 3J/cm2 10J/cm2 10J/cm2 1ms 30J/cm2 50J/cm2 50J/cm2 10ms 150J/cm2 Time to reading: Initial reading approximately 20s after exposure, Initial reading approximately 10s after final reading 40s after exposure exposure, final reading 20s after exposure Weight: 1.2Kg 300g Temperature compensation: Temperature compensated to give accurate readings independent of starting probe temperature Maximum permitted probe temperature: 70degC before measurement, 140degC after measurement Swivel mount: Handle swivels ±90 degrees vis a vis absorber for ease of use. Display: 2x8 character LCD. Character height 5mm Operation models: AUTO: Automatic measurement with laser set to 10s timed exposure. Unit senses temperature rise and measures automatically. MANUAL: User places probe in front of beam for 10s. Unit beeps to indicate start and stop measurement points. History: Stores last three readings Calibration: Can be recalibrated by user Battery: 2 x AA. Lifetime in normal use approximately 1 year Electromagnetic compatibility: CE approved Note a: For centered top hat beam Ordering Information Item Comet 10K-V1 Comet 10K HD Comet 1K Description Hand held power probe for 200 - 10,000W Hand held power probe for 200 - 10,000W with beam spreading cone in center for high damage threshold Hand held power probe for 20 - 1000W www.ophiropt.com 44 Ophir P/N 1Z02705 1Z02703 1Z02702 Approximate Spectral Absorption and Damage Threshold of Ophir Thermal Surface Absorbers 100 BB Thermal Laser Power & Energy 90 ABSORTIVITY IN % 80 70 60 50 40 30 20 10 0.1 1 10 20 30 10 20 30 Heads 0 WAVELENGTH IN µm 100 LP 90 70 60 50 40 Displays ABSORTIVITY IN % 80 30 20 10 0 0.1 1 WAVELENGTH IN µm 10 1 BB 0.3 LP 0.1 CW W / cm LP 2 0.01 10-10 10-9 1 nsec 10-8 10-7 10-6 10-5 1 µsec 10-4 10-3 10-2 1 msec 10-1 1 1 sec PULSE WIDTH IN SECONDS Note a: With BB (broadband) coating, slight cosmetic damage that does not affect calibration may occur at 3 - 10KW/cm2 Maximum power and energy density ratings of thermal BB and LP coatings vary with power level and beam diameter. In general, highest values of shaded area in curve are for powers below 300W and beam diameters below 1mm. For larger beam diameters the maximum power and energy density ratings approach the lower values in the shaded area. For model 30A, the maximum energy density even for long pulses is limited to 2J/cm2. It is recommended to use model 30(150)A-HE/HE1 for long pulse length high energy single shot lasers. Rating is for single pulses and is considerably less for repetitive pulses. www.ophiropt.com 45 Integrated Systems 100 OEM Products 1K (CW) POWER DENSITY W / CM2 ENERGY DENSITY IN J / CM2 LP > 1500W a BB thermal > 1500W a Beam Profile Wavelength BB Thermal < 300W a Pulsed Laser Damage Threshold 10K Thermal Volume Absorbers for Short and Long Pulse Lasers 3A-P CW & Pulsed Measurements 60 W-3W 20 J-2J Recommended Use: Very low power and energy pulsed lasers Special Features: Very sensitive, low noise, spectrally flat Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Thermal drift (30 min.) Power Accuracy: Maximum Energy Density J/cm2 b Response Time with Display (0 - 95%): Linearity with Power: Linearity with Energy: Energy Threshold: Energy Scales: Cooling: Dimensions: P type, 0.15 - 6µm Ø12mm 3W / 300mW/30mW/3mW/300µW 50W/cm2 4µW 5 - 30µW a ±3% single shot 10-30Hz 10 1 2.5s ±1.5% ±2% ±4µJ 20µJ 2J / 200mJ / 20mJ / 2mJ / 200µJ Convection See drawing 3A-P 48 30 Ø12 Ø70 19 Ø23 97-143 ADJUSTABLE Notes: a. Depending on typical room airflow and temperature variations b. For shorter wavelengths derate to values shown: Wavelengths Derate to value 355nm 40% 266nm 10% 193nm 10% 30º 75 100 12A-P CW & Pulsed Measurements 200 W-12W 200 J-30J Recommended Use: High energy pulsed lasers, dermatology and scientific applications Special Features: High sensitivity, spectrally flat, very high dynamic range 12A-P Absorber: Aperture: Digital power scales: Maximum average power density: Power noise level: Thermal drift (30 min.) Power accuracy: Maximum energy density J/cm2 Response time with display (0 - 95%): Linearity with power: Energy scales: Energy threshold: Linearity with Energy: Dimensions: Cooling: P type, 0.19 - 6µm Ø16mm 12W / 2W/200mW/20mW/2mW 50W/cm2 80µW 40 - 150µW a ±3% single shot 10-30Hz 10 1 3.5s ±1.5% 30J / 3J / 300mJ / 30mJ / 3mJ b 1mJ ±1.5% ±50µJ See drawing Convection Notes: a. Depending on typical room airflow and temperature variations. b. For the 30mJ energy scale measurements it is recommended to use the screw on barrel supplied with the head to protect from direct air flow 38 Ø80 7 Ø16 45˚ ADJUSTABLE 19 102-134 44 ADJUSTABLE 107 - 150 43 ø85 100 75 75 100 Ordering Information Item 3A-P-V1 12A-P Fiber adapters www.ophiropt.com Description 3W power/energy meter for low energy pulsed lasers 12W power/energy meter for pulsed lasers See page 55 for ordering information 46 Ophir P/N 1Z02622 1Z02624 30A-P Laser Power & Energy CW & Single Pulse Measurements 60mW-30W 30mJ-30J Recommended Use: Single pulsed Q-switched lasers, low average power pulsed lasers Special Features: Broad spectral range Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Maximum Energy Density J/cm2 a: P type, 0.19 - 6µm Ø17mm 30W / 3W 50W / cm2 3mW ±3% single shot 10 Response Time with Display (0 - 95%): 2.5s Linearity with Power: ±1% Energy Scales: 30J / 3J Energy Threshold: 30mJ Cooling: Convection 10-30Hz 1 43 Ø85 Heads Ø17 ADJUSTABLE 102-134 40% 10% 10% 100 30A-P-DIF 75 Displays Note a: For shorter wavelengths derate to values shown: Wavelength: 355nm Derate to value: 266nm 193nm 30A-P 30A-P-DIF CW & Pulsed Measurements 60mW-30W 30mJ-30J P type, 0.19 - 6µm a Ø16mm 30W / 3W 30 Watts continuous 500W / cm2 3mW Diffuser IN Diffuser OUT 3J / cm2 1J / cm2 2J / cm2 1J / cm2 ±5% 2.5s typ ±1% 30J / 3J 30mJ Convection 1J / cm2 0.4J / cm2 ±3% Diffuser IN Diffuser OUT 77 43 Ø17 Ø85 Ø25 REMOVABLE DIFFUSER ASSEMBLY ADJUSTABLE 102-134 Note a: With diffuser in, head is only calibrated at wavelengths listed. 100 75 Integrated Systems Absorber: Aperture: Digital Power Scales: Maximum Average Power: Maximum Average Power Density: Power Noise Level: Maximum Energy Density J/cm2 for 10ns pulses and 10-30Hz: 1064nm 532nm 355nm Power Accuracy: Response Time with Display (0 - 95%): Linearity with Power: Energy Scales: Energy Threshold: Cooling: Beam Profile Wavelength Recommended Use: Concentrated beam Q-switched lasers Special Features: Diffuser to spread out concentrated pulsed laser beams Item 30A-P 30A-P-DIF P absorber Fiber adapters Description 30W power/energy meter for pulsed lasers 30W power/energy meter for pulsed lasers with diffuser for concentrated beams up to 500W/cm2 Replacement absorber for user installation for 30A-P-V1 heads See page 55 for ordering information www.ophiropt.com 47 Ophir P/N 1Z02613 1Z02616 19509 OEM Products Ordering Information 30A-N CW & Single Pulse Measurements 60mW-30W 30mJ-200J Recommended Use: Concentrated beam YAG lasers Special Features: Very high damage threshold for power density Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy: Maximum Energy Density J/cm2: N type, 1064nm, 532nm Ø17.5mm 30W / 3W 5KW / cm2 3mW ±3% 30A-N 44 43 Ø85 Ø17.5 1J/cm2 1µS: 0.5ms: 20J/cm2 >5ms: >100J/cm2 Response Time with Display (0 - 95%): 2s typ ±1% Linearity with Power: 200J / 30J / 3J Energy Scales: 30mJ Energy Threshold: Convection Cooling: ADJUSTABLE 102-134 100 75 30(150)A-HE/HE1 CW & Single Pulse Measurements 50mW-150Wa 50mJ-200J Recommended Use: High energy and average power pulsed lasers. HE: YAG + harmonics, Holmium, Erbium / HE1: Ruby, Alexandrite, Erbium Special Features: Very high damage threshold, high average power. HE type, 0.19-3µm except 625-900nm HE1 type: 0.19-0.76µm, 2.9µm Ø17mm Aperture: 150W / 30W/3W a Digital Power Scales: Maximum Average Power: 30 Watts continuous, 150 Watts intermittent Maximum AveragePower Density: 500W / cm2 3mW Power Noise Level: ±3% Power Accuracy: single shot 10-30Hz Maximum Energy Density J/cm2 b 10ns 5 2 0.5ms 100 25 5ms 250 60 Response Time with Display (0 - 95%): 3.8s, typ Linearity with Power: ±1% Energy Scales: 200J/30J/3J Energy Threshold: 50mJ Cooling: Convection Absorber: Notes: a. b. Max power is 30W continuous, 150W intermittent For shorter wavelengths derate to values shown: Wavelength Derate to value 355nm 50% 266nm 50% 193nm 10% 30(150)A-HE/HE1 43 Ø85 Ø17 ADJUSTABLE 102-134 100 75 Ordering Information Item 30A-N 30(150)A-HE 30(150)A-HE106 30(150)A-HE1 30(150)A-HE1-755 Fiber adapters Description 30W power/energy meter for concentrated or high energy YAG beams 30/150W power/energy meter for wavelength 0.19-625 and 0.9-3µm. Energy calibrated for 0.19-0.6µm and 2.9µm 30(150)A-He with energy calibration for 1.064µm 30/150W power/energy meter for high pulse energies, 0.19-0.76µm. Energy calibrated for 0.694µm (Ruby laser) 30(150)A-HE1 with energy calibrated for 0.755µm (Alexandrite laser) See page 55 for ordering information www.ophiropt.com 48 Ophir P/N 1Z02003 1Z02380 1Z02385 1Z02382 1Z02387 30(150)A-HE-DIF 30(150)A-HE-DIF Laser Power & Energy CW & Pulsed Measurements 50mW-150W 50mJ-30J Recommended Use: Concentrated beam Q-switched lasers. Special Features: Diffuser to spread out concentrated pulsed beam HE type, 0.19-3µm except 625-900nm a Ø16mm 150W / 30W / 3W 30 Watts continuous, 150 Watts intermittent 500W / cm2 3mW Diffuser IN 5J/cm2 4J/cm2 1.5J/cm2 ±5% 3.8s typ ±1% 30J / 3J 50mJ Convection Diffuser IN Diffuser OUT 2J / cm2 2J / cm2 1J cm2 ±3% Diffuser OUT 77 43 Ø17 Ø85 Ø25 Heads Absorber: Aperture: Digital Power Scales: Maximum AveragePower: Maximum AveragePower Density: Power Noise Level: Maximum Energy Density J/cm2 for 10ns pulses and 10-30Hz: 1064nm 532nm 355nm Power Accuracy: Response Time with Display (0 - 95%): Linearity with Power: Energy Scales: Energy Threshold: Cooling: REMOVABLE DIFFUSER ASSEMBLY ADJUSTABLE 102-134 Note a: With diffuser in, head is only calibrated for wavelengths listed 75 Displays 100 30(150)A-SV CW & Pulsed Measurements 50mW-150W 50mJ-300J SV type, 0.19 - 12µm Ø17mm 150W / 30W / 3W 30 Watts continuous, 150 Watts intermittent >100KW/cm2 3mW >2J/cm2 40J/cm2 >100J/cm2 ±3% 1.5s typ ±1% 300J / 30J / 3J 50mJ Convection Beam Profile Wavelength Absorber: Aperture: Digital Power Scales: Maximum AveragePower: Maximum AveragePower Density: Power Noise Level: Maximum Energy Density J/cm2 10ns 0.5ms 2ms Power Accuracy: Response Time with Display (0 - 95%): Linearity with Power: Energy Scales: Energy Threshold: Cooling: 30(150)A-SV 43 Ø85 Ø17 Integrated Systems Recommended Use: Both high power density and energy density Special Features: Extremely high damage threshold for average power and single pulses ADJUSTABLE 102-134 100 75 Item 30(150)A-HE-DIF 30(150)A-SV Fiber adapters www.ophiropt.com Description 30(150)A-HE with diffuser for concentrated beams up to 500W/cm2 30/150W power/energy meter with extremely high damage threshold See page 55 for ordering information 49 Ophir P/N 1Z02354 1Z02625 OEM Products Ordering Information F100A-HE/HE1 CW & Single Pulse Measurements 120mW-100W 50mJ-200J Recommended Use: High energy and average power pulsed lasers. HE: YAG + harmonics, Holmium, Erbium HE1: Ruby, Alexandrite, Erbium Special Features: Very high damage threshold, high average power. Absorber: HE type: 0.19-3µm except 625-900nm HE1 type: 0.19-0.76µm, 2.9µm Aperture: Ø25mm Digital Power Scales: 100W / 30W Maximum AveragePower Density: 500W / cm2 Power Noise Level: 6mW Power Accuracy: ±3% Maximum Energy Density J/cm2 a single shot 10-30Hz 10ns 5 2 0.5ms 100 25 5ms 250 60 Response Timewith Display (0 - 95%): 3.8s, typ Linearity with Power: ±1% Energy Scales: 200J / 30J / 3J Energy Threshold: 50mJ Cooling: Fan Note a: For shorter wavelengths derate to values shown: Wavelength Derate to value 355nm 50% 266nm 50% 193nm 10% F100A-HE/HE1 115 115 89 45 12.5 89 Ø24 ADJUSTABLE 106-152 100 75 Ordering Information Item F100A-HE F100A-HE-106 F100A-HE1 www.ophiropt.com Description As 30(150)A-HE (page 48) for 100W average power As 30(150)A-HE-106 (page 48) for 100W average power As 30(150)A-HE1 (page 48) for 100W average power 50 Ophir P/N 1Z02430 1Z02432 1Z02431 Approximate Spectral Absorption of Thermal Volume Absorbers 100 P SV Laser Power & Energy HE1 90 LP 80 SV 10.6µm HE ABSORTIVITY IN % 70 60 50 40 30 Heads 20 10 0 0.1 1 10 20 30 WAVELENGTH IN µm Displays Pulse Energy Rating for Ophir Thermal Volume Absorbers Pulsed Laser Damage Threshold 1K 100 P 10 2 1 0.1 CW W / cm LP 2 Beam Profile Wavelength HE / HE1 (CW) POWER DENSITY W / CM2 ENERGY DENSITY IN J / CM2 10K 10-8 10-7 10-6 10-5 1 µsec 10-4 10-3 10-2 1 msec PULSE WIDTH IN SECONDS Note: Power and energy density is derated as follows: Absorber 193nm 248-266nm 355nm P type derate to 10% derate to 10% derate to 40% HE/HE1 type derate to 10% derate to 50% derate to 50% Rating is for single pulses and is considerably less for repetitive pulses www.ophiropt.com 51 10-1 1 1 sec OEM Products 10-10 10-9 1 nsec Integrated Systems 0.01 Thermal Excimer Heads L30A-EX CW & Single Pulse Measurements 80mW-30W 20mJ-30J Recommended Use: Medium aperture excimer lasers, Cu vapor lasers, TEA lasers Special Features: Sensitive, spectrally flat in UV, compact L30A-EX Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy Response Time with Display (0-95%): Linearity with Power: Energy Scales: Energy Threshold: Cooling: EX absorber, 0.15-0.4µm, 10.6µm Ø29mm 30W / 3W 44 43 2KW/cm2 4mW ±3% 1.5s ±1% 30J / 3J / 300mJ 20mJ Convection Ø29 Ø85 ADJUSTABLE 102-134 100 75 L40(150)A-EX CW & Single Pulse Measurements 200mW-150Wa 80mJ-200J Recommended Use: Large aperture, low power excimer lasers, Cu vapor lasers, TEA lasers Special Features: Sensitive, spectrally flat in UV, low profile Absorber: Aperture: Digital Power Scales: Maximum Average Power Density: Power Noise Level: Power Accuracy Response Time with Display (0-95%): Linearity with Power: Energy Scales: Energy Threshold: Cooling: L40(150)A-EX EX absorber, 0.15-0.4µm, 10.6µm Ø50mm 150W / 20W a 2KW/cm2 15mW ±3% 2.5s ±1% 200J / 30J / 3J 80mJ Convection 90 33 100 75 Ø50 ADJUSTABLE 107-152 Note a: Max power is 35W continuous, 150W intermittent. Ordering Information Item L30A-EX L40(150)A-EX-V1 www.ophiropt.com Description Large aperture 30W excimer power/energy meter Large aperture 35/150W excimer power/energy meter 52 Ophir P/N 1Z02194 1Z02614 FL250A-EX Laser Power & Energy CW & Single Pulse Measurements 200mW-250W 50mJ-200J Recommended Use: Large aperture excimer lasers, Cu vapor lasers, long pulse lasers Special Features: Sensitive, spectrally flat in UV, compact EX absorber, 0.15-0.4µm, 10.6µm Ø50mm 250W / 30W 2KW/cm2 10mW ±3% 2.5s ±1% 200J / 30J / 3J 50mJ Convection Heads Absorber: Aperture: Digital Power Scales: Maximum Ave. Power Density: Power Noise Level: Power Accuracy: Response Time withDisplay (0 - 95%): Linearity with Power: Energy Scales: Energy threshold Cooling: 115 Ø50 Displays FL250A-EX 118 44.5 89 44.5 12.5 89 75 Integrated Systems 100 Beam Profile Wavelength ADJUSTABLE 106 - 152 Ordering Information Description Large aperture 250W excimer power/energy meter Large aperture 250W excimer power/energy meter with electrical calibration option Ophir P/N 1Z02391 1Z02393 OEM Products Item FL250A-EX FL250A-EX-CAL www.ophiropt.com 53 Approximate Spectral Absorption of EX Absorbers 100 EX 90 ABSORTIVITY IN % 80 70 60 50 40 30 20 10 0 0.1 1 10 20 30µ WAVELENGTH IN µm Pulse Energy Rating for Ophir Surface & Volume Absorbers Pulsed Laser Damage Threshold 1K 100 (CW) POWER DENSITY W / CM2 ENERGY DENSITY IN J / CM2 10K 10 2 1 0.5 EX 0.1 CW W / cm 2 0.01 10-10 10-9 1 nsec 10-8 10-7 10-6 10-5 1 µsec 10-4 10-3 10-2 1 msec PULSE WIDTH IN SECONDS www.ophiropt.com 54 10-1 1 1 sec Fiberoptic Adapters and Accessories for Thermal Heads Ø32 Ø32 Ø32 13 7 2 13 7 2 13 M20x1 M20x1 M20x1 Ø25 Ø25 Ø25 3A-P/10A-SMA 3A-P/10A-ST 3A-P/10A-FC 1Z02216 1Z02214 1Z02215 48 118 F.O. ADAPTER MOUNTING BRACKET F.O. ADAPTER MOUNTING BRACKET Ø25 2 89 6 F.O. ADAPTER F.O. ADAPTER M20x1 75 75 30A/L30A FL250A with F.O. input with F.O. input SMA F.O. adapter for 30A/L30A/F100A and FL250A 1G01236 55 Integrated Systems 45 43 www.ophiropt.com Beam Profile Wavelength 2 OEM Products 7 Displays Heads Laser Power & Energy The heads can work either with or without the adapters attached Ordering Information for Fiber Adapters for Thermal and Photodiode Heads Head Series Fiber adapter mounting bracket (1 bracket will fit all fiber adapters) SC Fiber adapter LC Fiber adapter ST Fiber adapter FC Fiber adapter SMA Fiber adapter PD300 PD300-IRG-V1 3A-IS-V1 F100A-IS 3A 3A-P-V1 10A-V1 12A / 12A-P 30A-V1 30A-P L30A-V1 L50A 30(150)A-HL 30(150)A-SV 30(150)A-HE / HE1 30(150)A-V1 L40(150)A-V2 / L50(150)A FL250A-V1 FL300A / FL300A-LP not needed not needed 1Z08213 1Z08213 not needed not needed not needed not needed 1Z08211 1Z08230 1Z08210 1Z08210 1Z08211 1Z08230 1Z08230 1Z08211 1Z08238 a 1Z08212 1Z08212 1Z08221 not available 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 1Z08227 not available 1Z08215 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z08228 1Z02210 not available 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z08226 1Z02213 1Z08216 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z08229 1Z02212 1Z08222 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 1G01236 Note a: The fiber mounting bracket for these heads is a triple adapter for mounting up to three different fibers looking at same head SH to BNC Adapter Ordering Information Item SH to BNC Adapter www.ophiropt.com Description Allows connection of smart head to voltage measuring device for measurement of raw voltage output 56 Ophir P/N 1Z11010