Lutron® |10 % lighting management dimming Eco-10®

advertisement
Lutron
®
| 10 % lighting management dimming
Eco-10
®
To maximize the benefits of a lighting
management system, use Eco-10 dimming
ballasts. Eco-10 offers 100 % to 10 %
dimming, and is ideal for use in any space
where saving energy is the primary goal,
and critical performance is secondary.
Eco-10 ballasts are available for a large
range of lamps, making them an ideal
choice for applications with many different
fixture types. In addition, Eco-10 ballasts
are fully compatible with the complete
line of Lutron 3-wire fluorescent controls.
For the complete listing of Eco-10 ballasts,
please see pages 24 and 26.
|
20 Lutron
•
Dims 2', 3' and 4' T5 linear lamps
•
Dims T8 linear and T8 U-bent lamps
•
Slim-profile design–just 1" high
•
Slim-profile design–just 1" high
•
Color-keyed push-in connectors
•
Color-keyed push-in connectors
Eco-10
Performance
®
| 10 %
Specifications
•
Continuous, flicker-free dimming from
100 % to 10 %
•
Lighting management dimming from
100 % to 10 % relative light output
•
3-wire line-voltage control for consistent
fixture-to-fixture dimming
•
No visible flicker
•
Total Harmonic Distortion (THD) less than 20 %
•
Power factor greater than .95
•
Ballast factor greater than .85 for T8 lamps
•
Ballast factor equal to 1.0 for T5 and T5-HO lamps
•
Frequency of operation greater than 25 kHz for
T8 lamps
•
Frequency of operation greater than 42 kHz for
T5 and T5-HO lamps
•
Inaudible in 27 dBA ambient environment
•
Inrush current limiting circuitry built-in (maximum
of 7 amps for 120 V and 3 amps at 277 V)
•
Internal fusing
•
Minimum lamp starting temperature 10 °C (50 °F)
•
Maximum ballast case temperature 75 °C (167 °F)
•
Lamps turn on at any dimmed level without
flashing to full brightness
•
Low harmonic distortion
•
Slim-profile and standard designs available
•
100 % performance tested
•
Ultra-quiet operation
•
Designed in the USA
•
5-year warranty (limited) with field service
commissioning (3-year warranty standard)
3-wire control
For the full offering of Eco-10 dimming ballast
controls by Lutron®, please see pages 42-43.
Hot
120 / 277 VAC
60 Hz Feed
Control
Hot
Dimmed Hot
Dimming Ballast
Neutral
Neutral
|
Lutron 21
Lutron
®
|
Lamps
Lamp
per
Watts
(Length) Ballast
NEW!
For the latest
model numbers:
www.lutron.com/3d
Hi-lume 3D universal voltage
digital multi-input dimming ballasts
®
1 % Dimming
Hi-lume 3D
Ballast
Ballast System System Efficacy
Ballast Input
Input
Case Voltage Current Power Factor Lumens Efficacy Factor
(W)
(BF)
(lm)2
(lm/W)2 (BEF)
Type1 (VAC) (A)
Relative
System
Efficacy
(RSE)
T5 Linear
1
H3D T528 C UNV 1 10
C
28 W
(48 in)
2
H3D T528 C UNV 2 10
C
120
0.27
32.5
1.00
2,900
88
3.04
0.85
240
0.13
32.2
1.00
2,900
88
3.04
0.85
277
0.12
32.1
1.00
2,900
89
3.07
0.86
120
0.54
65.0
1.00
5,800
89
1.53
0.86
240
0.26
64.0
1.00
5,800
89
1.54
0.86
277
0.23
64.1
1.00
5,800
90
1.55
0.87
120
0.30
35.1
1.00
3,000
85
2.85
0.91
240
0.15
35.0
1.00
3,000
86
2.85
0.91
277
0.13
34.8
1.00
3,000
86
2.87
0.92
120
0.34
40.1
1.17
3,510
88
2.92
0.93
240
0.17
40.0
1.17
3,510
88
2.92
0.94
277
0.15
39.7
1.17
3,510
88
2.95
0.94
120
0.58
66.5
1.00
6,000
90
1.50
0.96
240
0.28
66.3
1.00
6,000
90
1.51
0.97
277
0.24
65.7
1.00
6,000
91
1.52
0.97
120
0.67
76.9
1.17
7,020
91
1.52
0.97
240
0.31
76.5
1.17
7,020
92
1.53
0.98
277
0.28
75.4
1.17
7,020
93
1.55
0.99
120
0.83
95.4
1.00
9,000
96
1.05
1.01
240
0.40
94.9
1.00
9,000
96
1.05
1.01
277
0.37
93.5
1.00
9,000
96
1.07
1.03
120
0.95
106.8
1.17
10,530
99
1.10
1.05
240
0.47
106.5
1.17
10,530
99
1.10
1.05
277
0.41
105.7
1.17
10,530
100
1.11
1.06
T8 Linear and U-Bent
H3D T832 C UNV 1 10
C
1
H3D T832 C UNV 1 17
H3D T832 C UNV 2 10
32 W
(48 in)
C
C
2
H3D T832 C UNV 2 17
H3D T832 G UNV 3 10
C
G
3
H3D T832 G UNV 3 17
G
When installing more than one ballast in a fixture, contact Lutron Technical
Support at 1.800.523.9466 for specific guidelines to maximize performance.
1 For case type information, see pages 34 and 35.
2 Actual number may vary with lamp model. Please consult the lamp manufacturer for lamp-specific data.
|
22 Lutron
Lutron
®
|
Lamps
Lamp
per
Watts
(Length) Ballast
NEW!
For the latest
model numbers:
www.lutron.com/3d
Hi-lume 3D universal voltage
digital multi-input dimming ballasts
®
1 % Dimming
Hi-lume 3D
Ballast
Ballast System System Efficacy
Ballast Input
Input
Case Voltage Current Power Factor Lumens Efficacy Factor
(W)
(BF)
(lm)2
(lm/W)2 (BEF)
Type1 (VAC) (A)
Relative
System
Efficacy
(RSE)
T8 Linear and U-Bent
H3D T825 C UNV 1 10
C
1
H3D T825 C UNV 1 17
C
25 W
(36 in)
H3D T825 C UNV 2 10
C
2
H3D T825 C UNV 2 17
C
120
0.25
30
1.00
1,900
64
3.34
0.84
240
0.12
29
1.00
1,900
66
3.46
0.87
277
0.11
29
1.00
1,900
65
3.44
0.86
120
0.29
34
1.17
2,223
66
3.46
0.87
240
0.14
33
1.17
2,223
67
3.53
0.88
277
0.12
34
1.17
2,223
66
3.49
0.87
120
0.49
59
1.00
3,800
64
1.69
0.85
240
0.24
56
1.00
3,800
68
1.79
0.89
277
0.22
56
1.00
3,800
68
1.79
0.89
120
0.55
64
1.17
4,446
69
1.83
0.91
240
0.27
62
1.17
4,446
72
1.89
0.95
277
0.24
62
1.17
4,446
71
1.88
0.94
120
0.19
23
1.00
1,300
57
4.39
0.75
240
0.09
23
1.00
1,300
58
4.42
0.75
277
0.08
23
1.00
1,300
57
4.37
0.74
120
0.20
26
1.17
1,521
59
4.57
0.78
240
0.10
25
1.17
1,521
60
4.62
0.79
277
0.09
25
1.17
1,521
60
4.62
0.79
120
0.32
39
1.00
2,600
66
2.56
0.87
240
0.16
38
1.00
2,600
68
2.60
0.89
277
0.14
39
1.00
2,600
67
2.58
0.88
120
0.36
43
1.17
3,042
71
2.71
0.92
240
0.18
42
1.17
3,042
73
2.81
0.95
277
0.15
42
1.17
3,042
73
2.80
0.95
T8 Linear and U-Bent
H3D T817 C UNV 1 10
C
1
H3D T817 C UNV 1 17
C
17 W
(24 in)
H3D T817 C UNV 2 10
C
2
H3D T817 C UNV 2 17
C
When installing more than one ballast in a fixture, contact Lutron Technical
Support at 1.800.523.9466 for specific guidelines to maximize performance.
1 For case type information, see pages 34 and 35.
2 Actual number may vary with lamp model. Please consult the lamp manufacturer for lamp-specific data.
|
Lutron 23
Lutron
Lamp
Type
®
|
Hi-lume , Compact SE , Eco-10
120 volt 3-wire dimming ballasts
®
™
Lamp
Lamps
Watts
per
Case
(Length) Ballast Type1
®
10 % Dimming
1 % Dimming
Hi-lume
For the latest
model numbers:
www.lutron.com/ballasts
5 % Dimming
Eco-10
Ballast
Current2
– Amps
T5 Linear
14 W
1
(21.6 in) 2
C3
C3
—
—
E 3 T514 C 120 1
E 3 T514 C 120 2
.17
.32
5/8 in Dia
21 W
1
(33.4 in) 2
C3
C3
—
—
E 3 T521 C 120 1
E 3 T521 C 120 2
.25
.43
28 W
1
(45.2 in) 2
C3
C3
—
—
ECO-T528-120-1
ECO-T528-120-2
.30
.55
T5-HO
Linear
24 W
1
(21.6 in) 2
C3
C3
FDB-T524-120-1
FDB-T524-120-2
ECO-T524-120-1
ECO-T524-120-2
.26
.45
5/8 in Dia
39 W
1
(33.4 in) 2
C3
C3
FDB-T539-120-1
FDB-T539-120-2
ECO-T5H39-120-1
ECO-T5H39-120-2
.38
.76
54 W
1
(45.2 in) 2
C3
C3
FDB-T554-120-1
FDB-T554-120-2
ECO-T554-120-1
ECO-T554-120-2
.58
1.1
T8 Linear
17 W
and U-Bent (24 in)
1
2
3
F
F
F
FDB-2427-120-14
FDB-2427-120-24
FDB-2427-120-3
ECO-T817-120-1
ECO-T817-120-2
ECO-T817-120-3
.19
.31
.43
1 in Dia
25 W
(36 in)
1
2
3
F
F
F
FDB-3627-120-14
FDB-3627-120-24
FDB-3627-120-3
ECO-T825-120-1
ECO-T825-120-2
—
.24
.43
.62
32 W
(48 in)
1
1
1
2
2
2
3
F
D
D
F
D
D
F
FDB-4827-120-14
—
—
FDB-4827-120-24
—
—
FDB-4827-120-34
—
ECO-T832-120-1-L
ECO-T832-120-1-T
—
ECO-T832-120-2-L
ECO-T832-120-2-T
ECO-T832-120-3
.30
.34
.34
.57
.53
.53
.82
40 W
(60 in)
1
2
F
F
FDB-6027-120-1
FDB-6027-120-2
—
—
.36
.64
When installing more than one ballast in a fixture, contact Lutron Technical
Support at 1.800.523.9466 for specific guidelines to maximize performance.
1
2
3
4
|
For case type information, see pages 34 and 35.
To calculate ballast input power, use the following formula: Watts = Ballast Current x 120.
Standard with terminals. Leaded options available. Please consult Lutron.
Use Hi-lume 3D ballasts (pages 22 and 23) for more efficient operation. Hi-lume dimming
ballasts for T8 lamps are not recommended for new specifications.
24 Lutron
Download