Datenblatt 9363232, 78210469, 78210808

advertisement
Dual-Band Combiner
1850 – 1910 / 1930 – 1990 MHz
1710 – 1755 / 2110 – 2155 MHz
PCS
AWS
• Designed for co-siting purposes
• Enables feeder sharing
• Suitable for indoor or outdoor applications
COM ANT
• With fault detection and integrated switch for multiple
DC power supply
AWS
PCS
782 10469
Typical Attenuation Curves
Diagram I
Technical Data
VSWR
936.3232
Subject to alteration.
Impedance
Input power
Port PCS
Port AWS
Intermodulation products
Power supply voltage
operational
survival
Polarity protection
Max. Current
Power supply current at PCS port
operating with dummy load
Lightning protection
Temperature range
Connectors
Application
Weight
Dimensions (w x h x d)
782 10808
Single unit
Double unit
1850 – 1910 (Rx) / 1930 – 1990 (Tx) MHz
1710 – 1755 (Rx) / 2110 – 2155 (Tx) MHz
Attenuation/dB
Pass band
PCS
AWS
Insertion loss
Port PCS ↔ Port ANT
Port AWS ↔ Port ANT
Isolation
Port PCS ↔ Port AWS
782 10469
-10
1850 – 1910
-20
-30
1930 – 1990
1710 – 1755
2110 – 2155
-50
< 0.3 dB (1850 – 1910 / 1930 – 1990 MHz)
< 0.2 dB (1710 – 1755 / 2110 – 2155 MHz)
-60
-70
> 50 dB (1850 – 1910 / 1930 – 1990 MHz)
> 50 dB (1710 – 1755 / 2110 – 2155 MHz)
< 1.25 (1850 – 1910 / 1930 – 1990 MHz)
< 1.25 (1710 – 1755 / 2110 – 2155 MHz)
50 Ω
-80
-90
-100
1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200
Frequency/MHz
< 250 W (1850 – 1910 / 1930 – 1990 MHz)
< 250 W (1710 – 1755 / 2110 – 2155 MHz)
< –160 dBc (3 rd order; with 2 x 20 W)
+10 … +15 V DC (Port PCS)
+10 … +30 V DC (Port AWS)
+10 … +35 V DC
–48 V DC (Port PCS, Port AWS)
1.5 A (Port ANT)
Port PCS ↔ Port ANT
0
-40
Diagram II
Port
Port
AWS ↔ ANT
Attenuation/dB
Type No.
Port AWS ↔ Port ANT
Port
Port
PCS ↔ ANT
Port
Port
AWS ↔ ANT
0
-0.1
-0.2
2110 – 2155
1710 – 1755
-0.3
1850 – 1910
100 mA ±20mA (+10 ... +15 V DC)
8/20 μs, 20 kA; 10/350 μs, 3 kA (Port ANT)
–40 ... +65 °C
7-16 female (long neck)
Indoor or outdoor (IP 66)
2.5 kg
5 kg
122 x 296 x 64 mm
122 x 296 x 120 mm
(including mounting brackets)
-0.4
1930 – 1990
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200
Frequency/MHz
Internet: http://www.kathrein.de
782 10469, 782 10808
Page 1 of 2
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494
Dual-Band Combiner
1850 – 1910 / 1930 – 1990 MHz
1710 – 1755 / 2110 – 2155 MHz
PCS
AWS
Accessories (order separately)
Type No.
Clamp set
suitable for mast
diameter of
734 360
34 – 60 mm
734 361
60 – 80 mm
734 362
80 – 100 mm
734 363
100 – 120 mm
734 364
120 – 140 mm
734 365
45 – 125 mm
Type No.
Description
793 301
Clamp Set
DC stop
DC stop
Side view
782 10469
Single Unit
4 screws M5 x 10
➀ ➁ 4 spring washers 5.5 DIN 6095 ➂ ➃
Side view
782 10808
Double Unit
➀➁
4 screws M5 x 10
4 spring washers 5.5 DIN 6095
➂➃
The mounting plates can be removed by loosening the screws ➀ to ➃ (M5 x 10) and replaced with other means of mounting, always provided that
the max. drilled depth of 8.5 mm is respected with the choice of replacement screws.
As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may
arise when products are used under extraordinary operating conditions.
Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures), may result
in the breakage of a mast mounted device or even cause it to fall to the ground.
These facts must be considered during the site planning process.
The Dual-band Combiners are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E and have passed environmental tests as recommended in ETS 300 019-2-4.
The installation team must be properly qualified and also be familiar with the relevant national safety regulations.
The details given in our data sheets have to be followed carefully when installing the antennas, filters, combiners, amplifiers and accessories.
The limits for the coupling torque of RF connectors, recommended by the connector manufacturers must be obeyed.
Any previous datasheet issues have now become invalid.
Page 2 of 2
782 10469, 782 10808
Internet: http://www.kathrein.de
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494
936.3232
Please note:
Subject to alteration.
Top view
782 10469 Single Unit,
782 10808 Double Unit
Download