Vectron International Filter specification TFS 90F 1/5

advertisement
Filename: tfs 90f.doc
Version 1.2
Vectron International
01.02.2012
Filter specification
TFS 90F
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
403 Ω || -29 pF
450 Ω || -28 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 90F is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The
nominal frequency fN is fixed at 90,0 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The
frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
6,5
Nominal frequency
fN
-
PB
Passband
p-p
Pass band ripple
dB
dB
... fN ±
0,63
arel
MHz
MHz ... fN ±
MHz ... fN ±
6,0
20,0
MHz
MHz
Relative attenuation
fN
fN ±
fN ±
2,0
6,0
-
max.
fN
±
10,0
dB
90,0
MHz
0,63 MHz
0,26
dB
max.
1,0
dB
1,81
3,42
MHz
MHz
min.
max.
1,26
4,0
0,26
dB
max.
1
dB
39
47
dB
dB
min.
min.
30
40
dB
dB
50
ns
max.
300
ns
16
dB
min.
10
dB
BW
Bandwidth
1
30
dB
tolerance / limit
Group delay ripple within fN ± 0,8 MHz
p-p
Return loss within PB
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf **
-
- 40 °C ... + 85 °C
-
- 40 °C ... + 85 °C
-15,5
ppm/K
MHz
MHz
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only.
Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Generated:
Checked / Approved:
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: tfs 90f.doc
Version 1.2
Vectron International
01.02.2012
Filter specification
TFS 90F
2/5
Filter characteristic
3.4
-1
3.16
-20
-2
2.92
-30
-3
2.68
-40
-4
2.44
-5
2.2
-6
1.96
-70
-7
1.72
-80
-8
1.48
-90
-9
1.24
-50
-60
-100
65.7
70.56
75.42
80.28
85.14
90
94.86
frequency in MHz
99.72
104.58
109.44
-10
88
114.3
88.4
88.8
89.2
89.6
90
90.4
frequency in MHz
90.8
91.2
91.6
delay in µs
0
-10
magnitude in dB
magnitude in dB
insertion loss: -7.39 dB
0
1
92
Construction and pin connection
(All dimensions in mm)
TPS-F-2417-3
1
10
X06
1,0± 0,2
1,91± 0,2
7,62± 0,2
5
Date code
1,9± 0,2
●
1,8± 0,2
6,5 ± 0,2
± 0,2
1
2
3
4
5
6
7
8
9
10
Input
Ground
Ground
Ground
Output RF Return
Output
Ground
Ground
Ground
Input RF Return
Date code:
X
A
B
...
Year + week
2009
2010
2011
6
50 Ω Test circuit
L1
1
10
6
SAW
L2
5
C2
C1
2, 3, 4, 7, 8, 9
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: tfs 90f.doc
Version 1.2
Vectron International
01.02.2012
Filter specification
TFS 90F
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
5. ESD
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
ANSI/ESD S20.20-1999, class 1A for HBM
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
1700
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
:24,00 +0,30/-0,10
Po
:4,00
± 0,1
Do
:1,50
+0,1/0
E
:1,75
± 0,10
F
:11,50 ± 0,10
G(min)
:0,60
P2
:2,00
± 0,1
P1
:12,00 ± 0,1
D1(min)
:1,50
Ao
:7,10
± 0,10
Bo
:13,90 ± 0,10
Ct
:21,5
± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
:24,4
+2/-0
W2(max) :30,4
N(min)
: 60
C
:13,0
+0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: tfs 90f.doc
Version 1.2
Vectron International
01.02.2012
Filter specification
TFS 90F
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max.
260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: tfs 90f.doc
Vectron International
Version 1.2
Filter specification
01.02.2012
TFS 90F
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
01.10.2008
1.1
- Change from development specification to filter specification
- Add terminating impedances
- Add typical values
- Add filter characteristics
- Add matching circuit
Alawneh
05.02.2009
1.2
- Customer request to update labelling, change form TFS90G to TPS-F-2417-3
TCUK
01.02.2012
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Download