MICRINS
®®
Distinctive Products for the Discriminating Surgeon
Endoscopic
Plastic Surgery
Instrumentation
For more information see your ERIEM representative or call 800.833.3380
ERIEM
Distinctive Products for the Discriminating Surgeon
ERIEM Surgical, Inc. • 28438 Ballard Drive, Lake Forest, IL 60045 • Phone 888.219.4211 • Fax 847. 549.1510 • www.micrins.com
MICRINS
Distinctive Products for the Discriminating Surgeon
MICRINS Endo-Forehead
Dissector
Commonly used for dissection of the lower
forehead and glabellar region. Long curved
shaft for access from high in hairline.
PR5056 11”
(28cm)
MICRINS Endo-Forehead
Arcus-Marginalis Dissector
Commonly used for dissection in the
subperiosteal plane. Long curved shaft for
dissection over orbital rim.
PR5051
10”
(25.5cm)
MICRINS Endo-Forehead
Spreader
Commonly used for incision of periosteum to
allow access to muscle and nerves.
PR5061
10 1/4”
(26cm)
MICRINS Endo-Forehead Flap
Dissector
Commonly used for separating the
intermediate from the deep temporal fascia
and elevation of periosteum on the zygomatic
arch.
PR5053
9 3/4”
(25cm)
ERIEM Surgical, Inc. • 28438 Ballard Drive • Lake Forest, IL 60045 • Phone 888.219.4211 • Fax 847.549.1510 •www.micrins.com
MICRINS
Distinctive Products for the Discriminating Surgeon
MICRINS Endo-Forehead “T”
Dissector
Commonly used for dissection in temporal
region. Also used for flap dissection in
standard rhytidectomy.
PR5062
9 7/8”
(25.3cm)
MICRINS Endo-Forehead
Dissector, Straight
Commonly used for initial dissection in the
subperiosteal plane.
PR5055
9 1/2” (24cm)
MICRINS Endo-Forehead
Dissector, Curved
Commonly used for initial dissection in the
subperiosteal plane. Curved to accommodate
forehead anatomy.
PR5054
9 1/2”
(24cm)
MICRINS Endo-Forehead
Parietal Elevator
Commonly used for initial posterior
dissection in the subperiosteal plane.
PR5060
10 1/2”
(26.5cm)
ERIEM Surgical, Inc. • 28438 Ballard Drive • Lake Forest, IL 60045 • Phone 888.219.4211 • Fax 847.549.1510 •www.micrins.com
MICRINS
Distinctive Products for the Discriminating Surgeon
DANIEL Endo-Forehead
Elevator
Semi-sharp outer edges for easy elevation of
periosteum. Commonly used for elevation in
the subperiosteal plane. Quarter curve for
most patients, half curve for patients with
high hairline.
PR5025 Half Cvd 9 ¼” (23.5cm)
PR5031 Qtr Cvd 9 ¼” (23.5cm)
DANIEL Endo-Forehead Scalp
Elevator
Commonly used for elevation in the subgaleal
or subperiosteal planes. Semi-sharp flat tip
permits tissue dissection atraumatically.
PR5036 Half Cvd 9 ¼” (23.5cm)
DANIEL Endo-Forehead Nerve
Dissector
Commonly used to dissect the nerves from the
muscle by stripping in an upward motion.
PR5028 Half Cvd 9 ¼” (23.5cm)
DANIEL Endo-Forehead Orbital Rim
Dissector
Commonly used over orbital rim. Sharp tip to
facilitate dissection in subperiosteal plane.
Sharp edges can be used to cut through
periosteum to expose muscle.
PR5033 Half Cvd 9 ¼” (23.5cm)
ERIEM Surgical, Inc. • 28438 Ballard Drive • Lake Forest, IL 60045 • Phone 888.219.4211 • Fax 847.549.1510 •www.micrins.com
MICRINS
Distinctive Products for the Discriminating Surgeon
DANIEL Endo-Forehead Nerve Hook
Commonly used to isolate nerves from muscles
thereby making debulking safe and easy.
PR5032 Half Cvd 9 ¼” (23.5cm)
DANIEL Endo-Forehead Scissors,
Curved
Commonly used to cut through periosteum and
muscle. Curved left or right to fit forehead
anatomy. Insulated for cauterization.
PR5029 Left 5” (12.5cm)
PR5030 Right 5” (12.5cm)
DANIEL Endo-Forehead Forceps,
Curved
Commonly used for muscle resection. Curved
left or right to fit forehead anatomy. Insulated
for cauterization.
PR5026 Left 5” (12.5cm)
PR5027 Right 5” (12.5cm)
DANIEL Endo-Forehead Punch, Curved
Commonly used for muscle resection. Curved
left or right to fit forehead anatomy. Insulated
for cauterization.
PR5034 Left 5” (12.5cm)
PR5035 Right 5” (12.5cm)
ERIEM Surgical, Inc. • 28438 Ballard Drive • Lake Forest, IL 60045 • Phone 888.219.4211 • Fax 847.549.1510 •www.micrins.com
MICRINS
Distinctive Products for the Discriminating Surgeon
Endoscope, Plastic Surgery, 5mm
Commonly used for endoscopic plastic surgery.
5mm diameter for excellent lighting and
visualization in smaller pockets. Highest quality
lenses provide high definition image.
PR5044
30°
7”
(17.5cm)
Endoscope, Plastic Surgery, 10mm
Commonly used for endoscopic plastic
surgery. Large 10mm diameter for excellent
lighting and visualization in large pockets.
Highest quality lenses provide high definition
image.
PR5039
30°
8”
(20.3cm)
DANIEL Endo-Forehead Cannula
Commonly used to retract dissected tissue
upwards exposing pocket for further
dissection. Fits over endoscope and locks in
place. With suction/irrigation port.
PR5024
fits 4mm or 5mm scopes
MICRINS Endo-Forehead Cannula
Commonly used to retract dissected tissue
upwards exposing pocket for further dissection.
Cobra tip for enhanced tissue elevation. Fits
over endoscope and locks in place. With
suction/irrigation port.
PR5022
fits 4mm or 5mm scopes
ERIEM Surgical, Inc. • 28438 Ballard Drive • Lake Forest, IL 60045 • Phone 888.219.4211 • Fax 847.549.1510 •www.micrins.com
MICRINS
Distinctive Products for the Discriminating Surgeon
EMORY Endo-Plastic Retractor
Commonly used in endoscopic breast
augmentation procedure. Also used in
abdominoplasty. Scope guide accommodates
10mm endoscope. Permits wide angle of
visualization during dissection of pocket.
Smoke evacuation incorporated in design.
PR5038 1” x 4 ¾” blade
EMORY Endo-Plastic Dissector
Designed to allow precise endoscopic dissection
of breast pocket during endoscopic breast surgery. Dissector is insluated to protect surrounding tissue. Smoke evacuation is incorporated in
design. Two per package, multiple use. Fits
PR5037 Electrode handle.
PR5040 14 1/2” (36.5cm) Left curved
PR5041 14 1/2” (36.5cm) Right curved
PR5042 14 1/2” (36.5cm) Straight
Electrode Handle
Used with electrodes for dissection during endoscopic plastic surgery. Suction incorporated
into handle design. Autoclavable.
PR5023
For more information see your ERIEM representative or call 800.833.3380
ERIEM
Distinctive Products for the Discriminating Surgeon