SECTION 10 14 00 SIGNAGE PART 1 1.01 GENERAL REFERENCES A. The following is a list of standards that may be referenced in this section: 1. 2. 3. 4. 5. 6. 7. 1.02 American Society of Mechanical Engineers (ASME): A13.1, Scheme for the Identification of Piping Systems. ASTM International (ASTM): a. A53/A53M, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded and Seamless. b. D709, Standard Specification for Laminated Thermosetting Materials. The Chlorine Institute, Inc.: WC-1, Wall Chart: Handling Chlorine Cylinders and Ton Containers. International Code Council (ICC): a. A117.1, Accessible and Usable Buildings and Facilities. b. International Fire Code (IFC): Chapter 27, Hazardous Materials-General Provisions. National Fire Protection Association (NFPA): a. 704, Standard System for the Identification of the Hazards of Materials for Emergency Response. b. HAZ-01, Fire Protection Guide to Hazardous Materials. Occupational Safety and Health Act (OSHA). U.S. Department of Transportation, Federal Highway Administration: Manual on Uniform Traffic Control Devices for Streets and Highways. SUBMITTALS A. Action Submittals: 1. B. Shop Drawings: a. Drawings showing layouts, actual letter sizes and styles, and Project-specific mounting details. b. Manufacturer’s literature showing letter sizes and styles, sign materials, and standard mounting details. Informational Submittals: Manufacturer’s installation instructions. PW/DEN001/650394 SEPTEMBER 17, 2015 ©COPYRIGHT 2015 CH2M HILL SIGNAGE 10 14 00 - 1 PART 2 2.01 PRODUCTS SIGNS A. Metal Sign (Type B): 1. 2. B. Fiberglass Sign (Type C): 1. 2. C. Material: Three-ply laminated fiberglass, minimum 1/8 inch thick, with contrasting color core message layer between two clear weatherresistant surface layers. Manufacturers: a. Best Manufacturing Co. b. Brady Signmark. Exit Sign (Type G): 1. 2. 3. 2.02 Material: Baked enamel finished 20-gauge (minimum) steel or 18-gauge (minimum) aluminum signs. Manufacturers: a. Seton Identification Products. b. Nutheme Illustrated Safety Co. Material: Plastic, 1/8 inch minimum thickness. Letters: a. 6 inches high, with 3/4-inch stroke. b. 2 inches wide, except for letter “I”, with spacing of 3/8 inch. Colors: Red letters and direction arrows on white background. IDENTIFICATION LABELS A. Pipe Labels: 1. 2. 3. 4. 5. 6. 7. 8. SIGNAGE 10 14 00 - 2 Snap-on, reversible type with lettering and directional arrows, sized for outside diameter of pipe and insulation. Provided with ties or straps for pipes of 6 inches and over diameter. Designed to firmly grip pipe so labels remain fixed in vertical pipe runs. Material: Heavy-duty vinyl or polyester, suitable for exterior use, long lasting, and resistance to moisture, grease, and oils. Letters and Arrows: Black on OSHA safety yellow background. Color Field and Letter Height: Meet ASME A13.1. Message: Piping system name as indicated on Piping Schedule. Manufacturers and Products: a. Brady Signmark; B-915 BradySnap-On and Strap-On Pipe Markers. b. Seton Identification Products; Ultra-mark Pipe Markers. PW/DEN001/650394 SEPTEMBER 17, 2015 ©COPYRIGHT 2015 CH2M HILL B. Equipment Labels: 1. 2. 3. 4. 5. 6. 7. 8. 2.03 ANCILLARY MATERIALS A. Fasteners: Stainless steel screws or bolts of appropriate sizes. B. Manufacturer’s standard brackets for wall mounting of two-sided exit signs. PART 3 3.01 3.02 Applies to equipment with assigned tag numbers, where specified. Letters: White engraved, 3/4 inch minimum high. Background: Black. Materials: Multi-layered acrylic. Furnish 1-inch margin with holes at each end of label, for mounting. Size: a. 2 inches minimum and 3 inches maximum high, by 14 inches minimum and 18 inches maximum long. b. Furnish same size base dimensions for all labels. Message: Equipment names and tag numbers as used in sections where equipment is specified. Manufacturers: a. Brady Signmark. b. Seton Identification Products. EXECUTION INSTALLATION—GENERAL A. In accordance with manufacturer’s recommendations. B. Mount securely, plumb, and level. SIGNS A. General: 1. 2. B. Fasten to walls or posts, or hang as scheduled. Anchor in place for easy removal and reinstallation with ordinary hand tools. Information, Exit, and Safety Signs: 1. 2. Install facing traffic. Locate for high visibility with minimum restriction of working area around walkways and equipment. Install as scheduled. PW/DEN001/650394 SEPTEMBER 17, 2015 ©COPYRIGHT 2015 CH2M HILL SIGNAGE 10 14 00 - 3 3.03 IDENTIFICATION LABELS A. Pipe Labels: 1. 2. 3. 4. 5. 6. B. Equipment Labels: 1. 2. 3.04 Locate at connections to equipment, valves, or branching fittings at wall boundaries. At intervals along piping not greater than 18 feet on center with at least one label applied to each exposed horizontal and vertical run of pipe. At exposed piping not normally in view, such as above suspended ceilings and in closets and cabinets. Supplementary Labels: Provide to Owner those listed on Piping Schedule that do not receive arrows. Apply to pipe after painting in vicinity is complete, or as approved by Engineer. Install in accordance with manufacturer’s instructions. Locate and install on equipment or concrete equipment base. Anchor to equipment or base for easy removal and replacement with ordinary hand tools. SUPPLEMENT A. The supplement listed below, following “End of Section,” is a part of this specification. 1. Sign Schedule: Tabulation of characteristics and mounting information for each sign on Project. Provide items as scheduled. Meet requirements of Occupational Safety and Health Act (OSHA). END OF SECTION SIGNAGE 10 14 00 - 4 PW/DEN001/650394 SEPTEMBER 17, 2015 ©COPYRIGHT 2015 CH2M HILL Sign Schedule Sign Size No.1 Type2 Format3 Width Height Lettering Mounting Color Location Method Height to Top Height Style Color Message Faces Other Requirements C-1 C 1014-002 20" 14" Yellow Hanging Chain 5'-6" 1" min. Helvetica Black CAUTION Equipment Starts Automatically 1 2 - in room 200201 & 200-101 C-2 C 1014-002 20" 14" Yellow Wall Bolts 5'-6" 1" min. Helvetica Black CAUTION Ear Protection Required 1 At door 200-D102C S-3 B 1014-011 7" 10" White Door/Wall Screws/ Bolts 5'–6" 2-1/2" Block Black NOT AN EXIT 1 On door 200-D102A X-1 G 1014-005 10" 14" White Wall Bolts 6'-0" 6" Block Red 1 At exterior stairwell door in Digester Expansion EXIT 1 Numbers refer to a particular sign type with a particular message. Letters refer to sign types specified in this section. 3 Numbers refer to Design Details that show sign layout. 4 Verify requirements for this sign with Laws and Regulations in state where Project is located. 2 PW/DEN001/650394 SEPTEMBER 17, 2015 ©COPYRIGHT 2015 CH2M HILL SIGNAGE 10 14 00 SUPPLEMENT - 1