ACDHUM ACDHUM - Air Change Dehumidification Unit First Australian made Dehumidification Unit with air to air counterflow plate heat exchange technology for temperature and humidity control. DX Packaged Unit 200-5000 L/s Chilled Water Unit 200-6000 L/s • Heat exchange technology enables pre-cooling and re-heating • Higher efficiency and superior humidity control over standard systems • Achieves high COP • Advanced Control System as standard • Complete packaged design • No return air required – 100% pressurisation • Improves indoor air quality with up to 100% outdoor air • Multi award winning Australian made, internationally patented technology Australian Innovation at its best airchange.com.au ACDHUM Features & Benefits Air Change Dehumidification Unit - DX or Chilled Water The specialised ACDHUM range is designed to provide a more energy efficient and cost effective solution for handling high latent loads. The ACDHUM unit efficiently pre-conditions the temperature and humidity of the building fresh air supply. The system is an ideal solution for situations where exhaust air cannot be recovered or used due to spill air contamination, building pressure requirements or the practical constraint of recovering exhaust air. Although it has been designed for hot and humid environments the ACDHUM is not only limited to that, it can be effectively used all year round. During winter or mild temperatures the reverse cycle capability provides efficient operation in heating mode. Product Range • DX Units from 200–5000L/s • Chilled Water Units from 200–6000L/s Backward curve fans Built-in high grade air filters High static fan *EC Plug Fan (standard for ACDHUM1) Advanced Control System (BACnet compliant) allows for virtual plug and play High efficiency sensible only air to air counter-flow plate heat exchanger Variable speed compressors Direct coupled fan & motor Scroll compressors Upgraded compressors for extra refrigeration capacity Standard Optional • Air to air counterflow plate sensible heat exchanger enables pre-cooling and re-heating • Advanced Control System (BACnet compatible) as standard • No return air required - 100% pressurisation • High COP - average measurement of 6 in an onsite situation and 10 under peak design conditions • Supplies 100% outdoor air for optimal IAQ • Complies with Section J of BCA • Complete packaged and factory tested units, with guaranteed performance • Assists with earning Green Star points and improves NABERS energy rating • Australian made, designed and patented award winning heat exchange technology How it works ines The ACDHUM system will cool and dehumidify hot and humid outside air to the supply air set point condition. In the cooling mode (see schematic below) outside air (1) is pre-cooled and dehumidified as it passes through the air to air sensible heat exchanger (2). The air is further cooled and dehumidified as it passes over the cooling coil (3) before being directed back through the counter path of the heat exchanger. This supply air is reheated to supply air set point temperature (4) as it passes back through the heat exchanger and its condition can be precisely trimmed via the bypass damper. The main source of energy efficiency is attributed to the heat exchanger, as only fan energy Project: Brigidine Street Contact: James Aye is required to pre cool and reheat the supply air. Psychrometric Chart Psychrometric Chart ACDHUM schematic ` 1 4 1 2 3 2 4 3 SA Fan 5 Bypass Damper Modulating Cooling Coil Drain Tray HX (Sensible) Bag Filter Point 10 Sydney Brisbane 15 20 25Location30 35 40 45 North 50Adeilade Melbourne Darwin Dry Bulb Temperature (°C) Queensland Perth 1. Outside Air Tdb/Twb (°C) 2. Air Off Heat Exchanger Cooling Tdb/Twb (°C) 35.5/24 33.5/26 34.5/27.5 25.5/21 23.5/23.5 40/23 37.5/21.5 34.5/28 40/23 25/25 29/20 26.5/18.5 27.5/25.5 29/20 Shane Carmichael 3. Air Off Coil Tdb/Twb (°C) 13/13 13/13 13/13 13/13 13/13 13/13 13/13 4. Supply Air After Reheat Tdb/Twb (°C) 24/17 24/17 24/17 24/17 24/17 24/17 24/17 Aldi QLD & NSW (various stores) Consultant DMA Professional Engineers Brisbane City Hall, QLD Consultant EMF Griffiths Installation Siganto and Stacey ACDHUM2-W & ACDHUM3-W Multi Award Winning Technology Coles, Cannon Hill, QLD Consultant DMA Professional Engineers Installation Cool Air Solutions ACDHUM2-D ARBS Industry Awards “ESD Product” Winner 2010 AIRAH “Excellence in HVAC” Winner 2003 (Qld) & 2006 (National) SEDA “Green Globe” Winner 2002 & 2003 Installations Gold Coast University Hospital, QLD Consultant SKM Installation Hastie Air Conditioning 13 various ACDHUM6-W, ACDHUM7-W & ACDHUM8-W Technical Data Dehumidification Units Model No ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM 1-D Nominal Flow Rate (L/s) 720 Supply Air 3-D 4-D 5-D 850 1100 1700 2400 < 150 External Static (Pa) Compressor Capacity 2-D 6-D 7-D 3500 4000 < 200 1-W 2-W 3-W 4-W 5-W 6-W 7-W 8-W 720 850 1100 1700 2400 3500 4000 5000 < 250 26 51 67 88 114 140 165 < 150 < 200 < 250 N/A Energy Reclaim# kWr) Precool 9.5 11.3 14.6 22.6 31.8 46.4 53.1 9.5 11.3 14.6 22.6 31.8 46.4 53.1 66.3 Reheat 9.5 11.3 14.6 22.6 31.8 46.4 53.1 9.5 11.3 14.6 22.6 31.8 46.4 53.1 66.3 Total 19 22.6 29.2 45.2 63.6 92.8 106.2 19 22.6 29.2 45.2 63.6 92.8 106.2 112.6 48.4% 48.4% 48.4% 48.4% Heat Exchanger Energy Savings 48.4% 48.4% 48.4% 48.4% 1 Compressor Type 48.4% 48.4% 48.4% 48.4% 48.4% 2 N/A R407C Refrigerant 48.4% 48.4% N/A 3 Phase Direct Couple Motor/Fan - VSD Controlled Fan Type Volts/ph/Hz 415 / 3 / 50 Construction 50mm sandwich panel, 0.6mm clad colourbond both sides. UV treated polymer joiners for maximum strength, insulation and durability Weight (kg) 640 975 1315 1743 2074 2536 2820 350 682 909 1211 1491 1834 2075 2424 # Data based on ambient 35.5°C/24°C and supply 24°C/17°C at nominal flow rate with 100% Outdoor Air. Specifications subject to change without notice. ACDHUM Schematic A B A B C C ACDHUM - D ACDHUM - W Dehumidification Unit Dimensions Size ACDHUM - D ACDHUM - W A (Width) B (Depth) C (Height) A (Width) B (Depth) C (Height) 1 1450 2590 2325 950 2590 1860 2 2100 2490 2325 1600 2490 1990 3 2750 2490 2325 2250 2490 1990 4 3550 2490 2375 2900 2490 1990 5 4200 2490 2375 3550 2490 1990 6 4850 2490 2450 4200 2490 2040 7 5500 2490 2450 4850 2490 2040 8 N/A N/A N/A 5500 2490 2040 Contact Air Change engineers for technical information or visit www.airchange.com.au airchange.com.au Offices NSW 02 9531 4699 VIC 03 9482 1010 QLD 07 3891 1974 Distributors NTH QLD 07 4775 5222 SA/NT 08 8354 0088 WA 08 9367 3288 TAS 03 6344 6888 New Zealand +64 3 343 6184 Air Change products internationally patent protected I Refrigerant Trading Authorisation No: AU23586 ACDHUM 2012