Data Sheet Z6AM Weighing module for 50 kg ... 500 kg Special features − Equipped with load cell Z6F... class C4 according to OIML R60 − With Overload stop and Transverse control arm − Maintenance-free − Compact installation at minimum installation height − Easy installation − Galvanized material and stainless steel version available − Self-restoring due to pendle bearing − Prepared for Lift-off securing device 15 Dimensions (in mm; 1 mm= 0.03937 inches) 200 155 22.5 15 79 60 65 M12* 50 100 ~120 17.5 150 22.5 14 20** 75 120 * in base plate ** in top plate B0986-3.0 en 14 Specifications of the weighing module Z6AM: Maximum capacity 50 kg Limit load Restoring force (at 1 mm side offset) 100 kg 200 kg % of Maximum capacity 150 % of Applied load 2.8 Maximum permissible side offset transverse to the control arm axis mm "3.5 Maximum permissible horizontal force in the control arm direction kN 5 500 kg Galvanized or Stainless steel Material Weight (depending on the version, incl. load cell) kg mm Adjustment range of the overload stop 8...9 ≤0.35 ≤0.25 ≤0.45 ≤0.8 For technical data and additional information on the appropriate load cells, please refer to the Data sheet Z6F... Cable assignment of the load cell (grey) (black) (white) (blue) Excitation (−) Signal (+) Excitation (+) (green) Sensor circuit (red) Signal (−) (yellow) HBM Sense Shield / wire strand connected with housing 2 B0986-3.0 en Survey of ordering codes: Weighing module Z6AM available with different options K-Z6AM Code Option1: Material V Galvanized R Stainless steel Code Option 2: Accuracy class C4 Class C4 C6 Class C6 (not possible with Option 3 / code 500) Code Option 3: Capacity 50 50 kg 100 100 kg 200 200 kg 500 500 kg Code Option 4: Ex protection according to ATEX 95 0 without 1 II 2 G EEx ia IIC T4 resp. T6 (Zone 1); II 2 D IP68 (Zone 21) 2 II 3 G EEx nA II T6 (Zone 2); II 3 D IP68 (Zone 22 for nonconductive dust) Code A 3m B 6 m (not possible with Option 2 = Code C6 and / or Option 4 = Code 1 or 2) C 12 m (not possible with Option 2 = Code C6 and / or Option 4 = Code 1 or 2) Codes on grey background identify the standard version which is available from stock at short notice notice. K-Z6AM ordering example K-Z6AM R Option 5: Cable length C4 1 0 0 2 A Scope of supply: Weighing module with load cell Z6FC4/... (Standard) or Z6FC6/... (Option), complete mounted with transverse control arm, pendle support and ground wire B0986-3.0 en 3 HBM Mounting examples for weighing modules with Transverse control arms: Arrangement of the weighing modules below cylindrical tanks 120° 120° Transverse control arm 120° Rectangular arrangement of the weighing modules below tanks Attention: The represented bearing arrangements consider only weighing−technical criteria. The carrying and stabilitymust be examined and guaranteed in each case by the operator. Modifications reserved. All details describe our products in general form only. They are not to be understood as express warranty and do not constitute any liability whatsoever. B0986-3.0 en Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45, D-64293 Darmstadt, Germany Tel.: +49 6151 8030; Fax: +49 6151 803 9100 E−mail: support@hbm.com www.hbm.com