Weighing module for 50 kg 500 kg Data Sheet

advertisement
Data Sheet
Z6AM
Weighing module
for 50 kg ... 500 kg
Special features
− Equipped with load cell Z6F...
class C4 according to OIML R60
− With Overload stop and
Transverse control arm
− Maintenance-free
− Compact installation at minimum installation height
− Easy installation
− Galvanized material and
stainless steel version available
− Self-restoring due to pendle
bearing
− Prepared for Lift-off securing
device
15
Dimensions (in mm; 1 mm= 0.03937 inches)
200
155
22.5
15
79
60
65
M12*
50
100
~120
17.5
150
22.5
14
20**
75
120
* in base plate
** in top plate
B0986-3.0 en
14
Specifications of the weighing module Z6AM:
Maximum capacity
50 kg
Limit load
Restoring force (at 1 mm side offset)
100 kg
200 kg
% of Maximum capacity
150
% of Applied load
2.8
Maximum permissible side offset transverse to
the control arm axis
mm
"3.5
Maximum permissible horizontal force in the
control arm direction
kN
5
500 kg
Galvanized or Stainless steel
Material
Weight (depending on the version, incl. load cell)
kg
mm
Adjustment range of the overload stop
8...9
≤0.35
≤0.25
≤0.45
≤0.8
For technical data and additional information on the appropriate load cells, please refer to the Data sheet Z6F...
Cable assignment of the load cell
(grey)
(black)
(white)
(blue)
Excitation (−)
Signal (+)
Excitation (+)
(green)
Sensor circuit
(red)
Signal (−)
(yellow)
HBM
Sense
Shield / wire strand connected with housing
2
B0986-3.0 en
Survey of ordering codes:
Weighing module Z6AM available with different options
K-Z6AM
Code
Option1: Material
V
Galvanized
R
Stainless steel
Code
Option 2: Accuracy class
C4
Class C4
C6
Class C6 (not possible with Option 3 / code 500)
Code
Option 3: Capacity
50
50 kg
100
100 kg
200
200 kg
500
500 kg
Code
Option 4: Ex protection according to ATEX 95
0
without
1
II 2 G EEx ia IIC T4 resp. T6 (Zone 1); II 2 D IP68 (Zone 21)
2
II 3 G EEx nA II T6 (Zone 2); II 3 D IP68 (Zone 22 for nonconductive dust)
Code
A
3m
B
6 m (not possible with Option 2 = Code C6 and / or Option 4 = Code 1 or 2)
C
12 m (not possible with Option 2 = Code C6 and / or Option 4 = Code 1 or 2)
Codes on grey background identify the standard version which is available from stock at short notice
notice.
K-Z6AM
ordering example
K-Z6AM
R
Option 5: Cable length
C4
1 0 0
2
A
Scope of supply:
Weighing module with load cell Z6FC4/... (Standard) or Z6FC6/... (Option), complete mounted with transverse control
arm, pendle support and ground wire
B0986-3.0 en
3
HBM
Mounting examples for weighing modules with Transverse control arms:
Arrangement of the weighing modules below cylindrical tanks
120°
120°
Transverse
control arm
120°
Rectangular arrangement of the weighing modules below tanks
Attention: The represented bearing arrangements consider only weighing−technical criteria. The carrying and
stabilitymust be examined and guaranteed in each case by the operator.
Modifications reserved.
All details describe our products in general form only. They
are not to be understood as express warranty and do not
constitute any liability whatsoever.
B0986-3.0 en
Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45, D-64293 Darmstadt, Germany
Tel.: +49 6151 8030; Fax: +49 6151 803 9100
E−mail: support@hbm.com www.hbm.com
Download