Internal Telephone Modem 3 (ITM3) Elster’s ITM3 provides modem communication capabilities to the ALPHA Plus® and A3 ALPHA® meters. The ITM3 has outage reporting capabilities, intrusion detection, and off-hook detection. The ITM3 option board is compatible with wide voltage range ALPHA Plus meters Release 2.7 or later. A3 ALPHA meters require Release 3.0 or later to support the ITM3 option board. Intrusion and Off-hook Detection Intrusion detection recognizes when another telephone extension sharing the telephone line is attempting a call while the modem is off-hook. When the modem detects another extension is attempting a call, the modem ceases communication and immediately disconnects allowing the other extension to use the line. The ITM3 option board also provides off-hook detection. Offhook detection recognizes that the telephone line is in use before the modem attempts a call. When it detects that the telephone line is already in use, the modem will follow the user-configured retry strategy to retry the call. Meters with RS-485 only Master RS-485 loop O E N Modem [ITM3 & RS-485] Figure 1. Line sharing enabled Dual Remote Port Access On the A3 ALPHA meter only, the ITM3 may be used to enable dual, simultaneous remote port access to the meter (see Figure 2). To enable, simply install the ITM3 plus a second communication option board (that is, RS-232 or RS-485) under the cover of the A3 ALPHA meter. You will be able to simultaneously access the meter over both communication links. This provides an economic solution for applications where a second party desires direct access to the meter (for example, end customer access, power grid management, etc.). Outage Reporting When equipped with an optional outage reporting battery, the ITM3 option board can report power outages that meets userspecificed criteria. ALPHA Plus meter outage reporting calls are made using the Elster Electricity protocol; A3 ALPHA meter outage reporting calls are made using ANSI C12.21 and C12.19. Line Sharing By using the ITM3 in association with Elster’s RS-485 option board, up to 31 meters may share the same telephone line with no external equipment to install or maintain (see Figure 1). In this application, the master meter is equipped with both an ITM3 and an RS-485 option board. Every other meter is equipped with only an RS-485 option board. All meters can be read by making a single telephone call. The ITM3 will support line sharing on both the ALPHA Plus and A3 ALPHA meter. O P E N Port 1 Telephone Port 2 RS-485 or RS-232 Simultaneous communications Figure 2. Dual remote port access (A3 ALPHA meter only) Extended Memory for A3 ALPHA Meters A3 ALPHA Meters When used on an A3 ALPHA meter, the ITM3 option board may be optionally provided with 1 MB of extended memory for additional interval data recording. This memory, when requested, is provided directly on the ITM3 circuit board. The A3 ALPHA meter builds upon the strengths of existing ALPHA meter designs. Like its predecessors, the A3 ALPHA meter users Elster Electricity’s patented digital measurement techniques that offer high accuracy, repeatability, and low ownership costs. In support of open architecture standards, the A3 ALPHA meter is the first Elster meter with full ANSI C12.18, C12.19, and C12.21 support. ALPHA Plus Meter The ALPHA Plus solid-state polyphase meter is a powerful meter that builds on the patented ALPHA metering technology. The ALPHA Plus meter can be a single phase, 240-volt, one-rate demand meter or a polyphase, wide voltage supply, multi-rate, real/reactive meter that validates meter service connections automatically, performs power quality monitoring, and provides load profile reading with remote communications. Any ALPHA Plus meter can be upgraded to any other configuration through option boards and reprogramming techniques. The ALPHA Plus meter is designed so that one meter can be applied at all line voltages ranging from 96 to 528 volts. The wide voltage range also eliminates the need for some commonly used ANSI wiring forms without the need to rewire existing sockets. The ITM3 option board requires wide voltage range ALPHA Plus meters release 2.7 or later. The A3 ALPHA meter supplies many standard features such as the following: • • • • self reads (up to 15 self reads may be stored) over 50 different instrumentation display quantities system service checking Class 0.2 accuracy for transformer rated and self-contained meters The ITM3 option board requires A3 ALPHA meters release 3.0 or later. Technical Specifications ITM3 Option Board Optional outage reporting battery operational life Communication rate S-base 1200 bps or 2400 bps A-base 6.95 [177] 1.35 [34] 6.95 [177] Over 100 outage reporting calls in a ten-year period 7.6 [193] 10.3 [262] 6.4 [162] 6.4 [162] 9.4 [238] 5.5 [139] 0.75 [19] LINE Dimensions in inches [millimeters]. For reference only. Do not use in construction. LOAD 2.56 [65] 2.5 [62] Elster Raleigh, North Carolina, USA +1 800 338 5251 (US toll free) +1 905 634 4895 (Canada) support@us.elster.com www.elster.com © 2005 by Elster. All rights reserved. Information herein is subject to change without notice. Product specifications cited are those in effect at the time of publication. Printed in the United States. Rev. A. July 2007.