Transformer Terminal, RET 541/543/545
Release Note
1MRS755546
January 21, 2005
Page 1 (4)
Handled by: Rainer Harju
RET 541/543/545
Release Note
Dear Reader
We are pleased to announce the release of new RET 541/543/545 Transformer Terminals. These terminals share the same reliable hardware platform and system software as in REF 541/543/545 Feeder
Terminals.
Application and
The main features of the new terminals are:
Technological highlights
•
Comprehensive protection function library for two-winding power transformers and generatortransformer blocks
•
Control, condition monitoring and measurement functions as in REF 541/543/545 Feeder
Terminals and REM 543/545 Motor and Generator Terminals
•
•
Automatic voltage regulator function as an option
Dual port communication with the following protocols: SPA, LON, IEC 60870-5-103, Modbus®
RTU/ASCII, DNP 3.0®; connectivity to Profibus-DP and IEC 61850 based systems via adapters
•
•
•
Three functionality levels: Control, Basic and Multi
Extensive language support
The RET 541/543/545 Transformer Terminals are supported by the following setting and
configuration tool versions:
CAP 505 Relay Product Engineering Tools v. 2.3.0-4
CAP 501 Relay Setting Tools v. 2.3.0-4
LNT 505 LON Network Tool v. 1.1.1-1
LIB 510 Application Library v. 4.0.5-2
SMS 510 v. 1.2.0-1-1
Distribution Automation
Power technology
products
Business identity code:
FI0763403-3
Domicle: Helsinki
Visiting Address
Strömberg Park,
Muottitie 2A
FIN-65100 Vaasa
FINLAND
Postal Address
P.O. Box 699
FIN-65100 Vaasa
FINLAND
Telephone
+358 10 2211
Telefax
+358 10 22 41599
+358 10 22 41094 Sales
Internet
www.abb.com/
substationautomation
e-mail:
firstname.lastname@fi.abb.com
Transformer Terminal, RET 541/543/545
Release Note
Product Verification
1MRS755546
January 21, 2005
Page 2 (4)
The substation automation system related functionality of the RET 541/
543/545 Transformer Terminals has been successfully tested and verified
in the DA System Test Laboratory at ABB Oy, Distribution Automation.
Dear Reader
Application and
Technological Highlights
Product Verification
Product Configurations and
The RET 541/543/545 Transformer Terminals can be ordered with different
Product Configurations
Ordering Information
functionality levels, analog input module versions and sets of digital inputs
and Ordering Information
and outputs. The type designation for the RET 54_ terminals is defined as
Checking the CPU
follows:
Capacity for the RET
541/543/545 Transformer Terminals
RET54_AB230AAAA
A = fixed display, B = external display module
Reserved for future use
Reserved for future use
Auxiliary voltage range of the power supply module and
voltage range of the digital inputs
A: power supply:
PS1/240 V (Medium) or PS2/240 V
Ur = 110/120/220/240 V AC;
110/125/220 V DC
digital inputs:
Ur = 110/125/220 V DC
threshold voltage:
Ut = 80 V DC
B: power supply:
PS1/240 V (High) or PS2/240 V
Ur = 110/120/220/240 V AC;
110/125/220 V DC
digital inputs:
Ur = 220 V DC
threshold voltage:
Ut = 155 V DC
C: power supply:
PS1/48 V (Low) or PS2/48 V
Ur = 24/48/60 V DC
digital inputs:
Ur = 24/48/60/110/125/220 V DC
Hardware number: 230, 231, 232, 233, 234, 235,
240, 241, 242, 243, 244, 245,
250, 251, 252
Functionality level: C = Control, B = Basic, M = Multi
Software revision: A
Transformer terminal type: RET 541, RET 543, RET 545
The type designation details both the hardware and the supported functionality level. The functionality available can be selected from three different levels: Control, Basic and Multi. When ordering, please separately state
the language combination and possible optional voltage regulator function. The user’s manuals must be ordered separately or you can download
them from our web address: http://www.abb.com/substationautomation.
Ordering example:
RET543AM240AAAA
with English and German language support and a voltage
regulator option COLTC 1MRS100144
The above statement is sufficient information to order a RET 543 Trans
former terminal with six current and three voltage transformer inputs, two
Additional information
Delivery Time and
Quantity
Transformer Terminal, RET 541/543/545
Release Note
digital I/O boards, Uaux = 80...265 Vdc/ac (Medium), binary input threshold
voltage 80 Vdc, no RTD1-card, fixed Graphical HMI. The available functions are according to the Multi-level functionality; see table in Appendix II.
The language combinations supported are detailed in the Technical over-
1MRS755546
January 21, 2005
Page 3 (4)
Dear Reader
Application and
Technological Highlights
view brochure (1MRS755543).
Product Verification
The outlook design of the RET 541/543/545 Transformer Terminal follows
Product Configurations
the new PT division design guideline "Power Technologies Guidelines for
and Ordering Information
Product Design". RE_ 541/543/545 series products with the old design
can also be ordered during a transition period of 6 months (until June 30,
Checking the CPU
2005). Should the customer wish to receive a product with the old design
Capacity for the RET
this shall be clearly notified in the purchase order with the text "Old de-
541/543/545 Trans-
sign". If there are no comments in the purchase order the customer will get
former Terminals
the product with the new design.
Additional information
Delivery Time and
Checking the CPU Capacity
Each function block engaged in the functional configuration reserves a
for the RET 541/543/545
portion of the CPU capacity of the transformer terminal. In order to ensure
Transformer Terminals
proper terminal performance, it is important that the CPU capacity is
checked before giving a customer a commitment for the selected functionality. Pay attention to the required number of stages for each function
and the system frequency (50 or 60 Hz).
An Excel template for CPU load checking is available in the Lotus Notes
database “Competitive Edge, Engineering Information”. When the functional configuration is downloaded to the RET 54_ transformer terminal,
the device also automatically checks the system resources and informs of
possible violations of the CPU capacity limit.
Additional Information
The available product-related user manuals and documents are listed in
Appendix III.
The Sales brochure and Technical overview brochure (TOB) are available
to help promoting and quoting this product. The material is available on
the Internet at http://www.abb.com/substationautomation.
Quantity
Transformer Terminal, RET 541/543/545
Release Note
Delivery Time and Quantity
1MRS755546
January 21, 2005
Page 4 (4)
A standard delivery time of 4-6 weeks (depending on the factory load situation) applies to orders for RE_ 541/543/545 series terminals of 24 units or
less. Please consult our sales representatives for the delivery time of larger
quantities. Please also take into account our weekly message “DELIVERY
Dear Reader
Application and
Technological Highlights
TIMES AND MAXIMUM DELIVERY QUANTITIES” giving the latest information concerning the present delivery situation.
Product Verification
Product Configurations
and Ordering Information
Checking the CPU
Yours faithfully
Capacity for the RET
541/543/545 Transformer Terminals
Rainer Harju
Additional information
Product Manager
Delivery Time and
ABB Oy, Distribution Automation
Appendix
Appendix II:
Hardware versions
Appendix II:
Functionality Levels
Appendix III: User Manuals and Documents
Quantity
Transformer Terminal, RET 541/543/545
Release Note, Appendix I
Appendix II: Description of RET 54_ hardware versions
Table 3.2.-1 Hardware versions of RET 541, 6I/3U transformers
1MRS755546
January 21, 2005
Page 1 (9)
Transformer Terminal, RET 541/543/545
Release Note, Appendix I
Table 3.2.-2 Hardware versions of RET 541, 7I/2U transformers
1MRS755546
January 21, 2005
Page 2 (9)
Transformer Terminal, RET 541/543/545
Release Note, Appendix I
Table 3.2.-3 Hardware versions of RET 541, 8I/1U transformers
1MRS755546
January 21, 2005
Page 3 (9)
Transformer Terminal, RET 541/543/545
Release Note, Appendix I
Table 3.2.-4 Hardware versions of RET 543, 6I/3U transformers
1MRS755546
January 21, 2005
Page 4 (9)
Transformer Terminal, RET 541/543/545
Release Note, Appendix I
Table 3.2.-5 Hardware versions of RET 543, 7I/2U transformers
1MRS755546
January 21, 2005
Page 5 (9)
Transformer Terminal, RET 541/543/545
Release Note, Appendix I
Table 3.2.-6 Hardware versions of RET 543, 8I/1U transformers
1MRS755546
January 21, 2005
Page 6 (9)
Transformer Terminal, RET 541/543/545
Release Note, Appendix I
Table 3.2.-7 Hardware versions of RET 545, 6I/3U transformers
1MRS755546
January 21, 2005
Page 7 (9)
Transformer Terminal, RET 541/543/545
Release Note, Appendix I
Table 3.2.-8 Hardware versions of RET 545, 7I/2U transformers
1MRS755546
January 21, 2005
Page 8 (9)
Transformer Terminal, RET 541/543/545
Release Note, Appendix I
Table 3.2.-9 Hardware versions of RET 545, 8I/1U transformers
1MRS755546
January 21, 2005
Page 9 (9)
Transformer Terminal, RET 541/543/545
Release Note, Appendix II
1MRS755546
January 21, 2005
Page 1 (2)
Handled by: Rainer Harju
Appendix II: Description of RET 54_ Functionality levels
Transformer Terminal, RET 541/543/545
Release Note, Appendix II
1MRS755546
January 21, 2005
Page 2 (2)
1MRS755546
January 21, 2005
Page 1 (1)
Transformer Terminal, RET 541/543/545
Release Note, Appendix III
Appendix III: RET 541/543/545 Transformer Terminal Related User Manuals and Documents
Manual
Revision
Document ID
Installation Manual
K
1MRS750526-MUM
Operator's Manual
H
1MRS750500-MUM
Transformer Terminal RET 54_ Technical
ReferenceManual, General
A
1MRS755225-MUM
Technical Descriptions of Functions, Introduction
N
1MRS750528
Technical Descriptions of Functions (CD-ROM)
V. 2.9
1MRS750889-MCD
Protection & Control Terminals RET 54_, REF 54_,REM
54_, REC 523 Configuration Guideline
H
1MRS750745-MUM
Functional description of Configuration Solution for Single
transformer system without tap changer control
A
1MRS755529
Functional description of Configuration Solution for Power
transformer with tap changer and parallel operationwith
Master/Follower principle
A
1MRS755530
Functional description of Configuration Solution for Power
transformer with tap changer and parallel operationwith
Minimizing Circulating Current principle
A
1MRS755531
Download