System Configuration Guide (V.8) (February / 2000) Notes ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P2 teamserver ES200----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P10 teamserver ES300----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P12 teamserver C800 series---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P14 teamserver MS400 ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P16 teamserver G800 series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P20 teamserver MS600 ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P22 teamserver HS900 ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P25 teamserver External Devices --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P27 teamserver Rackmount ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P28 Hardware ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P29 Index Key to The numbers on the left hand side of each page correspond to the various options available with teamservers as follows : CPU slot RAM module slot 3.5 inch HDD Bay 5 inch Bay RS-232C PCI slot ISA slot Redundant PSU Others Or 1 And NOTES Disk array configuration • Physical pack • Logical drive • Partition • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• A collection of physical HDDs comprising a RAID. Logical drive (ex. D: ) seen by the Operating System. One of the logical access units into which a logical drive is divided. Physical pack HDD HDD HDD HDD Logical drive A Partition 1 Logical drive B * Drives can be divided into partition. Partition 2 Logical drive C <Restrictions> (1) Physical pack must contain the same type(size) of HDDs. (2) Maximum logical drive size is 2TB (GP5U141/U142/-143/-144/-146). (3) The number of HDDs comprising a physical pack is as shown below. RAID Level ) RAID 0 ) RAID 1 RAID 5 RAID 6 Discription The data is broken down into blocks,each on a separate disk drive Duplicates the disk and writes the same data onto two disks. ) The data is broken down into blocks and each blocks is written together with parity bits on a separate disk drive. ) Duplicates the disk and broken down into blocks,each on a separate disk. (RAID0+1) HDDs Capacity of logical drives ( - 2~8 The capacity of logical drive is same as the capacity of connected HDD. ( - The capacity of the logical drive is half the capacity of connected HDD. ( ( 2 - 3~8 The capacity of each logical drive is the number of connected HDDs - 1). - 3~8 The capacity of each logical drive is the half the capacity of connected HDD. (GP5143/144/145) *GP5U141/142: RAID6 is available with Firmware 4.04-F-56 or greater (4) The same RAID level must be use when dividing a physical pack into a number of logical drives. (5) A physical pack must contain only HDDs which are connected by the same RAID card. (6) A RAID card can support more than one physical pack. ( even if different RAID levels) (7) In case of the same capacity HDD is connected with one RAID Card, the revolution of HDD also must be the same. 9GB 7200rpm 9GB 7200rpm 9GB 10000rpm This must be 9GB with 7200rpm HDD! RAID Hard disk cabinet/RAID card/SCSI card ●Hard disk cabinet GP5MS622A: Up to two can be connected Note: The operating System must be installed on an internal hard disk. ●RAID card (GP5U141/GP5-144/GP5-146) 1.Up to two Hard disk cabinets can be connected with one RAID card. (Up to three can be connected with one GP5-144 card) 2.When using GP5U141 in ES200/C800i/G800i, a RAID Card cannot be used for both external disk array (GP5UR1DC4/GP5MS622A) and internal disk array. 3.Internal and external array devices cannot be connected to the same channel. 4.GP5-144/146 can only be used with GP5-144/146, they cannot be mixed with (GP5U141/142/-143) 5.Up to two GP5-146 can be used for internal array configuration in G800i 6.When installing three RAID cards in G800i, the internal HDD must be connected using GP5-144 7.GP5-128 SCSI cannot be used in conjunction with any RAID Card in MS600. 2 NOTES ●RAID card (GP5U142/GP5-143) Only for use with internal devices. Only one of these RAID cards can be used per server. In MS400, GP5-143 cannot be used if the Drive Cage Conversion Kit (GP5BBU1) is installed ●SCSI card (GP5-125/GP5-126/GP5-127/GP5-128) 1.Internal and external devices cannot be connected to the same SCSI card. 2.Maximum number of daisy chain connections allowed : (1) Up to four external devices (but not Hard disk cabinets) can be connected by daisy chain. (2) Only one Hard disk cabinet can be connected. (Daisy chain connection is not available) 3.GP5-128 is for connecting internal Ultra160 HDD 4.GP5-128 SCSI cannot be used in conjunction with any RAID Card in MS600. Number of connectable Hard Disk Cabinet Product ES200 ES300 MS400 MS600 HS900 C800i G800i Hard Disk Node Hard Disk Cabinet Storage System GP5MS622A GP5UR1DC4 2 – 4 4 4 4 4 4 – 12 4 4 4 4 Mounting internal devices in HS900 In HS900, there are two HDD bays (9GB/18GB/36GB disks are available) as system disks. Storage System (GP5UR1DC4) is required for data storage. HS900 has no internal 5" bay in chasis, so Backup cabinet (GP5UR1BC1) is required to mount backup devices. Mounting internal SCSI device (HDD/Backup device) in MS600/MS400 ●Drive Cage Conversion Kit (GP5BBU1) Applicable products : MS600/MS400 - Standard Drive Cage SCSI Channel : Number of mountable HDD : 1ch 8 (8HDDs per 1ch) Mountable HDD : 1inch/1.6inch height Hard Disk Drive - Drive Cage Conversion Kit (GP5BBU1) SCSI Channel : Number of mountable HDD : 2ch 12 (6HDDs per 1ch x 2) Mountable HDD : 1inch height Hard Disk Drive ●NOTES 1.1.6inch height hard disk drives [36GB:GP5-HDH62/GP5BHDH62] cannot be mounted when using the Drive Cage Conversion Kit (GP5BBU1). 2.Ultra 160 SCSI interface (GP5-128 in MS600/Onboard Wide A/B ch in MS400) must be used for Ultra 160 SCSI Hard Disk Drives (GP5HDH9A/GP5-HDH87/GP5-HDH62). [MS600] 3.SCSI Card (GP5-128) is required for Ultra160 SCSI. 4.Two SCSI Cards (GP5-128) are required when the Drive Cage Conversion Kit (GP5BBU1) is used in MS600 [MS400] 5.An additional PSU is required if the Drive Cage Conversion Kit is installed in MS400. 6.In MS400, GP5-143 cannot be used if the Drive Cage Conversion Kit (GP5BBU1) is installed. Please use GP5-144/GP5-146. 7.SCSI Card (GP5-127/GP5B127) and SCSI Cable (GP5-842/GP5B842) are required for mounting Narrow connect backup devices in case that Drive Cage Conversion Kit (GP5BBU1) is applied 3 NOTES The following figure indicates the right adapters (Onboard SCSI channel, SCSI Card, etc.) used to mount devices in MS600/MS400. teamserver MS600 Connection of internal HDD and internal backup devices Onboard SCSI Narrow For backup device (Narrow) Wide A For HDD Wide B For HDD / backup device (Wide) Internal HDD Configuration Internal backup device Drive Cage SCSI Interface Connection Pattern Host Cable Internal HDD Ultra2 Wide Onboard SCSI (Ch.A) Cable(✕1) (Standard equipment) 1) 2) 3) 4) 5) Ultra160 SCSI Card (GP5-128) Cable(✕1) (Standard equipment) 1) 9GB, 10,000rpm 2) 18GB, 10,000rpm 3) 36GB, 10,000rpm Cable(✕2) (Standard equipment) 1) 2) 3) 4) 1) 9GB, 10,000rpm 2) 18GB, 10,000rpm One device is connected Two devices are connected Narrow connect device*2 Narrow device ✕ 2 9GB, 7,200rpm 18GB, 7,200rpm 9GB, 10,000rpm 18GB, 10,000rpm 36GB, 10,000rpm Wide device ✕ 2 Narrow device and Wide device Onboard SCSI (Wide B) connection Wide-1 Onboard SCSI(WideB) Wide-2 SCSI Card(GP5-127) Narrow: Onboard SCSI(Narrow) Wide: Onboard SCSI(Wide B) SCSI Card (GP5-127 *3/*4) Wide-1 SCSI Card(GP5-127) Wide-2 SCSI Card(GP5-127) Narrow: Onboard SCSI(Narrow) WideI SCSI Card (GP5-127) Wide-1 SCSI Card(GP5-127) Wide-2 SCSI Card(GP5-127) Narrow: Onboard SCSI(Narrow) Wide: SCSI Card (GP5-127) Wide-1 SCSI Card(GP5-127) Wide-2 SCSI Card(GP5-127) Narrow: Onboard SCSI(Narrow) Wide: SCSI Card(GP5-127) Wide connect device*3 Standard (8Bays) SCSI Configuration Onboard SCSI Ultra2 Wide (Ch.A/B) When Drive Cage Conversion (12Bays)*1 Standard (8Bays) Ultra160 SCSI Card (GP5-128) ✕2 Cable(✕2) (Standard equipment) Ultra2 Wide RAID Card GP5-144/146 (Ch0) Cable(✕1) (Standard equipment) Array Configuration 1) 2) 3) 4) 5) 9GB, 7,200rpm 18GB, 7,200rpm 9GB, 10,000rpm 18GB, 10,000rpm Onboard SCSI (Narrow) connection SCSI Card (GP5-127 *3) Narrow-1,2 Onboard SCSI(Narrow) Daisy chain connection SCSI Card (GP5-127 *3) 9GB, 7,200rpm 18GB, 7,200rpm 9GB, 10,000rpm 18GB, 10,000rpm 36GB, 10,000rpm Narrow: Onboard SCSI(Narrow) Wide-1 Onboard SCSI(WideB) Wide: Onboard SCSI(WideB) Wide-2 SCSI Card(GP5-127) Onboard SCSI (Wide B) connection 1) 9GB, 7,200rpm When Drive Cable(✕2) 2) 18GB, 7,200rpm Cage RAID Card 3) 9GB, 10,000rpm (Standard Ultra2 Wide 4) 18GB, 10,000rpm GP5-144/146 (Ch0/1) Conversion equipment) (12Bays)*1 *1 Narrow connect devices: GP5UDL201/GP5UDT301/GP5USL501 *2 Wide connect devices: GP5-DT401/GP5-ML301/GP5-DL351 *3 Daisy chain is not available for connection of Wide SCSI connection device to SCSI Card (GP5-127) *4 SCSI Card (GP5-127) is required in case of Ultra 160 SCSI configuration, because GP5-128 cannot be used with Onboard Wide channel. teamserver MS400 Connection of internal HDD and internal backup devices Onboard SCSI Narrow For backup device (Narrow) Wide A For HDD/backup device (Wide) Wide B For HDD Internal HDD Internal backup device (Max.2) Connection Pattern Connection Select either of the SCSI chnnel Drive Cage SCSI Interface Ultra2 Wide Host Onboard SCSI (Ch.B) Cable Cable(✕1) (Standard equipment) Standard (8Bays) Ultra160 Onboard SCSI (Ch.B) Cable(✕1) (Standard equipment) Ultra2 Wide Onboard SCSI (Ch.A/B) Cable(✕2) (Standard equipment) Ultra160 Onboard SCSI (Ch.A/B) Cable(✕2) (Standard equipment) Ultra2 Wide RAID Card GP5-143/144/146 (Ch0) Cable(✕1) (Standard equipment) SCSI Configuration When Drive Cage Conversion (12Bays)*1 Standard (8Bays) Array Configuration When Drive Cage Conversion (12Bays)*1 Ultra2 Wide RAID Card GP5-144/146 (Ch0/1) Cable(✕2) (Standard equipment) Internal HDD 1) 2) 3) 4) 5) 9GB, 7,200rpm 18GB, 7,200rpm 9GB, 10,000rpm 18GB, 10,000rpm 36GB, 10,000rpm Onboard SCSI (Narrow) connection 9GB, 7,200rpm 18GB, 7,200rpm 9GB, 10,000rpm 18GB, 10,000rpm 1) 9GB, 10,000rpm 2) 18GB, 10,000rpm 1) 2) 3) 4) 5) 9GB, 7,200rpm 18GB, 7,200rpm 9GB, 10,000rpm 18GB, 10,000rpm 36GB, 10,000rpm 1) 2) 3) 4) 9GB, 7,200rpm 18GB, 7,200rpm 9GB, 10,000rpm 18GB, 10,000rpm Two devices are connected Narrow device ✕2 Max. 8HDDs 1) 9GB, 10,000rpm 2) 18GB, 10,000rpm 3) 36GB, 10,000rpm 1) 2) 3) 4) One device is connected Narrow connect device*2 Wide connect device*3 Wide device ✕2 Narrow device and Wide device Narrow: Onboard SCSI(Narrow) Wide: Wide-1 Narrow-1,2 Onboard SCSI(WideA) SCSI Card(GP5-127) Onboard SCSI(Narrow) or Onboard SCSI (WideA) Daisy chain connection connection Wide-2 Narrow: SCSI Card (GP5-127) SCSI Card(GP5-127) SCSI Cable(GP5-842) Wide: Onboard SCSI(Narrow) Narrow-1,2 SCSI Card (GP5-127) SCSI Cable (GP5-842) Max. 12HDDs Max. 8HDDs *1 Additional PSU (GP5-PU161) is required *2 Narrow connect devices: GP5UDL201/GP5UDT301/GP5USL501 *3 Wide connect devices: GP5-DT401/GP5-ML301/GP5-DL351 *4 Daisy chain is not available for connection of Wide SCSI connection device to SCSI Card (GP5-127) 4 Daisy chain connection Wide-1 with SCSI Card (GP5- SCSI Card(GP5-127) 127)/SCSI Cable (GP5842) Wide-2 SCSI Card (GP5-127) Narrow: SCSI Card(GP5-127) SCSI Cable(GP5-842) Wide: SCSI Card(GP5-127) Narrow: Onboard SCSI(Narrow) Wide: Wide-1 Onboard SCSI(WideA) SCSI Card(GP5-127) or Onboard SCSI (WideA) Onboard SCSI(Narrow) Daisy chain connection Wide-2 connection Narrow: SCSI Card (GP5-127) SCSI Card(GP5-127) SCSI Cable(GP5-842) Wide: Onboard SCSI(Narrow) Narrow-1,2 Onboard SCSI (Narrow) connection Max. 12HDDs SCSI Card (GP5-127) *4 NOTES Mounting internal SCSI device (HDD/Backup device) in ES300 teamserver ES300 Connection of internal HDD and internal backup devices Onboard SCSI Narrow For backup device (Narrow) Wide A For HDD/backup device (Wide) Wide B For HDD Internal HDD (Max.2) Internal backup device Connection Pattern Connection SCSI Interface Ultra2 Wide Host Cable Onboard SCSI (Ch.B) Cable(✕1) (Standard equipment) Internal HDD 1) 2) 3) 4) Select either of the SCSI chnnel One device is connected Two devices are connected Narrow connect device*1 Narrow device ✕2 Wide connect device*2 Wide device ✕2 9GB, 7,200rpm 18GB, 7,200rpm 9GB, 10,000rpm 18GB, 10,000rpm Narrow-1,2 SCSI Configuration Ultra160 Onboard SCSI (Ch.B) RAID Card Array Configuration Ultra2 Wide GP5-143/144/146 (Ch0) Cable(✕1) (Standard equipment) Cable(✕1) (Standard equipment) 1) 9GB, 10,000rpm 2) 18GB, 10,000rpm 1) 2) 3) 4) Onboard SCSI(Narrow) connection 9GB, 7,200rpm 18GB, 7,200rpm 9GB, 10,000rpm 18GB, 10,000rpm Narrow device and Wide device Narrow device: Wide-1 Onboard Onboard SCSI(WideA) SCSI(Narrow) connection Onboard Wide-2 Onboard SCSI(WideA) SCSI Card SCSI(Narrow) connection (GP5-127)*3 Daisy chain connection Wide device: SCSI Card(GP5-127) *1 Narrow connection devices: GP5UDL201/GP5UDT301/GP5USL501 *2 Wide connection devices: GP5-DT401/GP5-ML301/GP5-DL351 *3 Daisy chain is not available for connection of Wide SCSI device to SCSI Card(GP5-127) Mounting internal SCSI device (HDD/Backup device) in ES200 teamserver ES200 Connection of internal HDD and internal backup devices There are two EIDE channel on Motherboard Onboard IDE Controler Secondary EIDE Primary EIDE For CD-ROM For HDD Internal HDD Internal backup device (Max:2) Connection Pattern Connection Interface Host Internal HDD One device is connected Two devices are connected Narrow connect device *1 Narrow device x 2 Wide device x 2 Narrow device and Wide device SCSI Card (GP5-126) Daisy chain with primary connected device SCSI Card (GP5-127 *3) connection (SCSI Card is required per device) Narrow device: SCSI Card (GP5-126) SCSI Cable (GP5-841) (SCSI Card can be used for both HDD and backup device) Wide connect device *2 1) 9GB, 7,200rpm SCSI Card (GP5-126) 2) 18GB, 7,200rpm SCSI Cable (GP5-841) SCSI Configuration Ultra2 Wide SCSI Card (GP5-126) SCSI Cable (GP5-843) SCSI IDE Configuration IDE UltraDMA/3 Onboard Primary IDE 3 Array Configuration Ultra2 Wide RAID Card (GP5-143) SCSI SCSI Cable (GP5-843) (SCSI Card can be used for both HDD and backup device) 1) 13GB, 5400rpm SCSI Card (GP5-127) SCSI Cable (GP5-840) 1) 9GB, 7,200rpm 2) 18GB, 7,200rpm *1 Narrow connect devices: GP5UDL201/GP5UDT301/GP5USL501 *2 Wide connect devices: GP5-DT401/GP5-ML301/GP5-DL351 *3 Daisy chain is not available for connection of Wide SCSI device to SCSI Card(GP5-127) 5 SCSI Card (GP5-127 *3) SCSI Card (GP5-127) Daisy chain with primary connected device Wide device: SCSI Card (GP5-127 *3) connection (SCSI Card is required per device) NOTES Mounting internal SCSI device (HDD/Backup device) in G800i G800i have eight HDD bays and 18.2GB HDD (1"height) can be mounted. SCSI Card (GP5-127) is required if DLT unit (GP5-DL351) or Tape unit (GP5-ML301) is installed Mounting internal SCSI device (HDD/Backup device) in C800i C800i have four HDD bays (3hotplug and 1non hotplug) and 18.2GB HDD (1"height) can be mounted. SCSI Card (GP5-125) is required if Tape unit (GP5-ML301) is installed Mountable Hard Disk Drive in each models Main unit ES200 Succesor HDD Product ID Product Hard disk drive-9GB Interface Height Revolution Hard disk drive-13GB GP5-HD9G3 GP5-HD9G3B GP5-HD8G1 GP5-HD8G1B GP5-HD3E1 Ultra2Wide Ultra2Wide Ultra2Wide Ultra2Wide UltraDMA/33 1" 1" 1" 1" 1" 7200rpm 7200rpm 7200rpm 7200rpm 5400rpm Hard disk drive-9GB Hard disk drive-9GB Hard disk drive-18GB Hard disk drive-18GB GP5-HD9G3 GP5-HDH96 GP5-HD8G1 GP5-HDH83 Ultra wide Ultra wide Ultra wide Ultra wide 1" 1" 1" 1" 7200rpm 7200rpm 7200rpm 7200rpm G800i Hard disk drive-9GB Hard disk drive-18GB GP5-HDH96 GP5-HDH83 Ultra2Wide Ultra2Wide 1" 1" 7200rpm 7200rpm ES300 Hard disk drive-9GB Hard disk drive-9GB Hard disk drive-18GB Hard disk drive-18GB GP5-HDH99 GP5-HDH9A GP5-HDH86 GP5-HDH87 Ultra2Wide Ultra 160 Ultra2Wide Ultra 160 1" 1" 1" 1" 7200rpm 10000rpm 7200rpm 10000rpm MS400 Hard disk drive-9GB Hard disk drive-9GB Hard disk drive-18GB Hard disk drive-18GB Hard disk drive-36GB GP5-HDH99 GP5-HDH9A GP5-HDH86 GP5-HDH87 GP5-HDH62 Ultra2Wide Ultra 160 Ultra2Wide Ultra 160 Ultra 160 1" 1" 1" 1" 1.6" 7200rpm 10000rpm 7200rpm 10000rpm 10000rpm MS600 Hard disk drive-9GB Hard disk drive-9GB Hard disk drive-18GB Hard disk drive-18GB Hard disk drive-36GB GP5-HDH97 GP5-HDH9A GP5-HDH84 GP5-HDH87 GP5-HDH62 Ultra2Wide Ultra 160 Ultra2Wide Ultra 160 Ultra 160 1" 1" 1" 1" 1.6" 7200rpm 10000rpm 7200rpm 10000rpm 10000rpm HS900 Hard disk drive-9GB Hard disk drive-18GB Hard disk drive-36GB GP5-HDH98T GP5-HDH85T GP5-HDH61T 1" 1" 1.6" 10000rpm 10000rpm 10000rpm Hard disk drive-18GB C800i Ultra2Wide Ultra2Wide Ultra2Wide Remarks For mounting in 5" bay For mounting in 5" bay IDE HDD Non hotplug Non hotplug S.M.A.R.T function S.M.A.R.T. function is available in the conbinations shown below: ■ : Corresponds , x:Does not correspond , -:N/A Internal Hard disk units IDE Models Hard disk cabinet SCSI Hard disks Standard Standard equipment equipment GP5UR1DC4/GP5MS622A SCSI card SCSI card RAID card RAID card GP5-126 GP5-127 GP5-128 GP5U141 GP5U142 GP5-143 GP5-144 GP5-146 GP5-125 GP5-127 GP5U141 ES200 ■ - ■ C800i - ■ - - - G800i - ■ - - - ES300 - ■ - - - MS400 - ■ - - - MS600 - ■ - - ■ HS900 - ■ - - - - - x ■ x - ■ x x - - - ■ - - ■ - - ■ ■ - - - ■ x - GP5-144 GP5-146 - ■ ■ - ■ - x - - - ■ - ■ ■ ■ - ■ - ■ ■ ■ - ■ - ■ ■ ■ - ■ - ■ ■ ■ - ■ - ■ ■ - - - - ■ ■ ■ ■ Caution: Intel LANDesk Server Manager or Fujitsu Servervisor is required for SMART function SMART function is not available with the NOS of NetWare/IntranetWare,Solaris 6 NOTES Mounting additional memory (HS900) A memory board with 16slots is standard equipment and up to 16GB memory can be mounted. When you add more than 16GB, an additional Memory Board (GP5-RB201) is required. When using two memory boards in HS900, the same memory size must be mounted on each board. (MS600) Mount the same capacity DIMM's in units of four. (Mounting of DIMM's with different capacities or a set of less than four DIMM's is not allowed) Mount the DIMM's in ascending order of their capacity. Use DIMM slots in the order from bank A (J1 to J4) to bank D (J13 to J16) (MS400/ES300) The mother board has four slots for RAM modules. Two slots are occupied for standard memory, so two DIMMs can be added. Shaded part (A) indicates the slots where standard memory is mounted. Additional memory can be mounted in slots (B) as in the figure below. A B A B (ES200/G800i/C800i) The mother board has four slots for RAM modules (including base memory), install RAM modules in slot number order. (teamserver ES200 has three slots) Configuration To Order Configuration To Order (CTO) is available in teamserver MS600/MS400/ES300/ES200. Products are provided with option (HDD, Memory, Backup device, etc.) mounted along with the requirement of customers. 1. How to be shipped [Main unit] [CTO option] (1) CPU+Chassis+Memory (2) Mount option in free slots Shippment + (3) Standard Memory/Drive Cage conversion 2. Applicable products for CTO (1) Main unit MS600/MS400/ES300/ES200 (2) Option (GP5BXXX) All options which are connectable with the servers above. Exclude Storage System (GP5UR1DC4)/Hard Disk Cabinet (GP5MS622A) CPU Field Upgrade Kit Additional Memory Standard Memory Conversion Kit Hard Disk Drive Drive Cage Conversion Kit Backup Device Redundant PSU SCSI Card/RAID Card SCSI Cable LAN Card Others GP5BFG203/GP5BFG202/GP5BFG201/GP5BFG206/GP5BFG204 GP5BRM1G/GP5BRM51G/GP5BRM25G/GP5BRM12G GP5BRM2K/GP5BRM1K/GP5BRM51K/GP5BRM25K/GP5BRM12K GP5BRM25H/GP5BRM12H/GP5BRM64H GP5BRU1GB/GP5BRU51B/GP5BRU2GB/GP5BRU1GD/GP5BRU51G/GP5BRU25D GP5BHDH62/GP5BHDH87/GP5BHDH9A/GP5BHDH84/GP5BHDH97/GP5BHDH86/GP5BHDH99 GP5BHD8G1/GP5BHD9G3/GP5BHD8G1B/GP5BHD9G3B/GP5BHD3E1 GP5BBU1 GP5BDT401/GP5BDT301/GP5BSL501/GP5BDL201/GP5BDL351/GP5BML301 GP5BUPU151/GP5BUPU161 GP5B126/GP5B127/GP5B128/GP5B143/GP5B144/GP5B146 GP5B840/GP5B841/GP5B842/GP5B843 GP5B183/GP5B185 GP5BUSM103 7 NOTES Number of mountable optional cards HS900 MS600 Maximum number of cards mounted Cards Product ID Bus RAID card (Ultra2wide LVD) GP5-144 PCI64 8 RAID card (Ultra2wide LVD) GP5-145/146 PCI64 SCSI card (Ultra2wide LVD) GP5-127 SCSI card (Ultrawide Diff) Fibre Channel Card REMARKS Total Cards Product ID Bus Maximum number of cards mounted SCSI card (Ultrawide Diff) GP5-123 PCI 2 8 SCSI card (Ultra2wide LVD) GP5-127 PCI 3 PCI64 6 SCSI card (Ultra2wide LVD) GP5-128 PCI 2 GP5-123 PCI64 2 RAID card (Ultra2wide LVD) GP5-144 PCI 3 GP5-FC101 PCI64 2 RAID card (Ultra2wide LVD) GP5-146 PCI 2 LAN card (1000Base-SX) GP5-183 PCI64 1 Fibre Channel Card GP5-FC101 PCI 2 LAN card (100Base-TX) GP5-184 PCI64 3 LAN card (1000Base-SX)GP5-183 Standard LAN card (100Base-TX) equipment Server Monitor Module 8 For external disk array 2 PCI64 1 GP5USM103 PCI64 1 1 MS400 SCSI card (Ultrawide Diff) SCSI card (Ultra2wide LVD) RAID card (Ultra2wide LVD) For external disk array 3 GP5-127 is also used for connecting internal backup devices (Wide connect devices) 7* PCI 1 Only can be mounted in PCI-A2 4 LAN card (100Base-TX) GP5-185 PCI 3 Standard LAN card (100Base-TX) equipment PCI 1 Mounted in PCI-A1(fixed) GP5USM103 PCI 1 Mounted only in PCI-A3 Cards Product ID Bus Maximum number of cards mounted Total RAID card (Ultra2wide LVD) GP5-143 PCI32 1 3 GP5-144 PCI64 2 2 Internal/external array configuration Internal backup devices/external hard disk drive Server Monitor Module Cards REMARKS Total ES300 Product ID Bus Maximum number of cards REMARKS Total GP5-123 PCI32 2 GP5-127 PCI32 3 To connect with GP5UR1DC4 /GP5MS622A/internal backup device GP5-144 PCI64 3 For internal/external array configuration RAID card (Ultra2wide LVD) RAID card (Ultra2wide LVD) GP5-146 PCI64 For internal array configuration SCSI card (Ultra2wide LVD) GP5-127 PCI32 3 For internal/external array configuration Fibre Channel Card GP5-FC101 PCI64 2 RAID card (Ultra2wide LVD) GP5-143 PCI32 1 RAID card (Ultra2wide LVD) GP5-146 PCI64 2 Fibre Channel Card GP5-FC101 PCI64 2 LAN card (1000Base-SX) GP5-183 PCI64 1 LAN card (100Base-TX) GP5-185 PCI32 3 3 For external disk array 3 REMARKS Internal array configuration 2 Internal/external array configuration 5 2 3 LAN card (1000Base-SX) GP5-183 PCI64 1 LAN card (100Base-TX) GP5-185 PCI32 3 GP5USM103 PCI32 1 Product ID Bus Maximum number of cards mounted GP5U141 PCI 2 GP5-143 PCI 1 Server Monitor Module 3 ES200 Cards Product ID Bus Maximum number of cards mounted Total SCSI card GP5-126 PCI 1 3 SCSI card GP5-127 PCI 3 REMARKS Internal HDD/backup device/external device 3 Fibre Channel Card GP5-FC101 PCI 2 RAID card (Ultra2 wide LVD) GP5-143 PCI 1 RAID card (Ultra2 wide LVD) 4 Internal array configuration 2 GP5-146 PCI 1 LAN card (1000Base-TX) GP5-183 PCI 1 LAN card (100Base-TX) GP5-185 Server Monitor Module Internal backup device/external device PCI 3 GP5USM103 PCI 1 Product ID Maximum number of cards mounted External array configuration 3 G800 Cards SCSI card (Ultrawide Diff) SCSI card (Ultrawide SE) SCSI card (Ultra2wide LVD) RAID card (Ultrawide SE) RAID card (Ultrawide) RAID card (Ultra2wide LVD) RAID card (Ultra2wide LVD) Fibre Channel Card C800i Bus Cards For external disk array Use for external SCSI devices (also GP5ML301) RAID card (Ultrawide SE) RAID card (Ultrawide SE) To connect with GP5UR1DC4 SCSI card GP5-123 PCI 2 PCI 3 GP5-127 PCI 3 GP5-125 PCI 3 GP5U141 PCI 2 5 Internal/external array configuration LAN card (1000Base-SX) GP5-183 PCI 1 GP5U142 PCI 1 Only for internal array configuration LAN card (100Base-TX) GP5-185 PCI 3 GP5-144 PCI 3 GP5USM103 PCI 1 PCI 2 Cannot be used with GP5U141/142 Internal/external array configuration Cannot be used with GP5U141/142 Server Monitor Module GP5-146 GP5-FC101 PCI 2 PCI 1 LAN card (100Base-TX) GP5-184 PCI 3 GP5USM103 PCI 1 3 REMARKS GP5-125 LAN card (1000Base-SX) GP5-183 Server Monitor Module Total 3 1 8 REMARKS Total 3 Internal/external array configuration 2 Only for internal array configuration Only for external SCSI devices 3 NOTES Differentiation between Servervisor and Intel LANDesk Server Manager Server monitoring software (Servervisor V1.0 and Intel LANDesk Server Manager V6.0) is bundled with all teamservers Differences in function between Servervisor and Intel LANDesk Server Manager are indicated below: Items Product Main function Alert function SMM support Required memory capacity Advantage Servervisor V1.0 ES200/ES300/C800i MS400/MS600/G800/ HS900 Server status monitoring Error notification Intel LANDesk Server Manager V6.0 All products Server status monitoring Error message Remote control WindowsNT performance monitoring (e.g. CPU/Memory utilization) Internet mail transmission Internet mail transmission SNMP Trap transmission SNMP Trap transmission Message box (*On the monitored Message box (*On the monitored server) server) Pager Activation by program No Yes 6–10MB 32–64MB Servervisor provides the minimum LDSM is suitable for systems employing functions required for server management remote central monitoring or SMM based to reduce the amount of resources used, monitoring to provide a more powerful making it convenient for a small-scale server management function. system without a dedicated manager. -Powerful functions -Simplified operation, light-weight -Easy to use *1 Remote monitoring is provided by System Walker plus LiveHelp. Remote control and WindowsNT performance monitor are provided by System Walker. *2 If the message box is to be displayed for server error detection, the message box must be logged on to the server. Errors that occur while the message box is not logged on can be reported using Internet mail and SNMP Trap. The event log also can be used to check whether such errors have occurred. 9 System Configuration teamserver ES200 teamserver ES200 CPU: Pentium®lll (700/600E/550EMHz), Cache (L1+L2) : 32KB+256KB/ Celeron (466MHz) x 1, Cache (L1+L2) : 32KB+128KB / 4x32bitPCI / CD-ROM / Onboard LAN (Std.) / Internal Hard Disk Drive Bay : 4 (Non Hotplug) Bundled S/W: Servervisor/Intel LANDesk® Server Manager/ServerWizard GP5T2A51A : [1CPU(Pentiumlll700MHz)/Pedestal Type] GP5T2AY1A : [1CPU(Pentiumlll600EMHz)/Pedestal Type] GP5T2AV1A : [1CPU(Pentiumlll550EMHz)/Pedestal Type] GP5T2A81A : [1CPU(Celeron466MHz)/Pedestal Type] <Items> Memory addition : Standard memory conversion : Connect HDD (SCSI configuration) : Internal backup device : Connect HDD (Array configuration) : Internal backup device : Others (NIC, PSU, etc.) : Go to A Go to B Go to C Go to D Go to E Go to F Go to G Memory A Max:768MB w Additional Memory-64MB (64MB SDRAM-DIMM✕1) GP5-RM64H/GP5BRM64H Standard : 128MB (128MB-DIMM✕1) Additional Memory-128MB (128MB SDRAM-DIMM✕1) GP5-RM12H/GP5BRM12H Additional Memory-256MB (256MB SDRAM-DIMM✕1) GP5-RM25H/GP5BRM25H B Standard Memory conversion option w Standard Memory Conversion Kit-256MB GP5BRU25D Internal HDD/Internal backup device (SCSI Configuration) C Max:Four HDDs Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) GP5-HD9G3/GP5BHD9G3 (For HDD bay:Up to 3HDDs can be mounted) GP5-HD9G3B /GP5BHD9G3B (For forth HDD mounted in 5"bay:Only one can be mounted) y SCSI Card GP5-126/GP5B126 SCSI Cable GP5-843/GP5B843 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) GP5-HD8G1/GP5BHD8G1 (For HDD bay:Up to 3HDDs can be mounted) GP5-HD8G1B/GP5BHD8G1B (For forth HDD mounted in 5"bay:Only one can be mounted) DAT unit (DDS3) GP5UDT301/GP5BDT301 Only one DDS3 can be mounted in "bay2" D SCSI Cable GP5-841/GP5B841 Tape unit GP5USL501/GP5BSL501 Max.2 backup devices can be mounted DAT unit (DDS4) GP5-DT401/GP5BDT401 y SCSI Card GP5-127/GP5B127 E Tape unit (MLR3) GP5-ML301/GP5BML301 SCSI Cable GP5-840/GP5B840 (IDE configuration) Max:2 IDE Disk can be mounted Haed Disk Drive-13GB (Ultra DMA, 5,400rpm) GP5-HD3E1/GP5BHD3E1 e (Array configuration) y RAID Card (8MB Cache, Ultra2 Wide SCSI, Only for internal HDD connection) GP5-143/GP5B143 Go to SCSI Hard Disk Drive as above SCSI Cable GP5-843/GP5B843 SCSI Card (GP5-127/GP5B127) is required for mounting backup device in each case as below: 1) Internal Array configuration 2) IDE configuration 3) Conbination of Array and IDE configuration F y DAT unit (DDS3) GP5UDT301/GP5BDT301 SCSI Card GP5-127/GP5B127 SCSI Cable GP5-840/GP5B840 Tape unit GP5USL501/GP5BSL501 Max.2 backup devices can be mounted DAT unit (DDS4) GP5-DT401/GP5BDT401 Tape unit (MLR3) GP5-ML301/GP5BML301 10 System Configuration G Others y LAN Card GP5-185/GP5B185 y LAN Card GP5-183/GP5B183 y Server Monitor Module GP5USM103/GP5BUSM103 11 System Configuration teamserver ES300 teamserver ES300 CPU: Pentium®lll (733MHz) x1 (~2) / Cache (L1+L2) : 32KB+256KB / Onboard SCSI (1xUltra160/Ultra2 Wide, 1xUltra160/Ultra2 Wide or Fast Narrow), 5x32bitPCI/CD-ROM / Onboard LAN (Std.) / Internal Hard Disk Drive Bay : 5 (Hotplug) Bundled SW:Servervisor/Intel LANDesk® Server Manager/ServerWizard GP5T3A61A : [1CPU(Pentiumlll733MHz)/Pedestal Type] GP5T3A61R : [1CPU(Pentiumlll733MHz)/Rackmount Type] <Items> CPU Field upgrade : Memory addition : Standard memory conversion : Connect HDD (SCSI configuration) : Connect HDD (Array configuration) : Internal backup device : Others (NIC, PSU, etc.) : [Pedestal type] Go to A Go to B Go to C Go to D Go to E Go to F Go to G [Rackmount type] A CPU q ® pentium CPU Field Upgrade Kit-53 (Pentiumlll 733MHz (256KB) ✕1) GP5-FG206/GP5BFG206 Memory B Max : 4GB (1GB DIMM x 4) w Additional Memory-128MB (64MB SDRAM-DIMM✕2) GP5-RM12K/GP5BRM12K Standard : 256MB (128MB-DIMM✕2) Additional Memory-256MB (128MB SDRAM-DIMM✕2) GP5-RM25K/GP5BRM25K Additioanl Memory-512MB (256MB SDRAM-DIMM✕2) GP5-RM51K/GP5BRM51K Additional Memory-1GB (512MB SDRAM-DIMM✕2) GP5-RM1K/GP5BRM1K Additional Memory-2GB (1GB SDRAM-DIMM✕2) GP5-RM2K/GP5BRM2K C Standard Memory conversion option Standard Memory Conversion Kit-512MB (256MB to 512MB) GP5BRU51G r Standard Memory Conversion Kit-1GB (256MB to 1GB) GP5BRU1GD Standard Memory Conversion Kit-2GB (256MB to 2GB) GP5BRU2GB Internal HDD D (Ultra160/Ultra2 Wide SCSI Configuration) Max : 5HDDs u To comprise Ultra160 configuration GP5-HDH9A/GP5BHDH9A GP5-HDH87/GP5BHDH87 must be used. Hard Disk Drive-9GB (Ultra2 Wide SCSI, 7,200rpm) 1"height/Hotplug GP5-HDH99/GP5BHDH99 Hard Disk Drive-18GB (Ultra2 Wide SCSI, 7,200rpm) 1"height/Hotplug GP5-HDH86/GP5BHDH86 Hard Disk Drive-9GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1"height/Hotplug GP5-HDH9A/GP5BHDH9A Hard Disk Drive-18GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1"height/Hotplug GP5-HDH87/GP5BHDH87 (Array Configuration) E 11 RAID Card (32MB Cache / Ultra2 Wide SCSI / 3ch / Battery Backup) GP5-144 / GP5B144 RAID Card (16MB Cache / Ultra2 Wide SCSI / 2ch / Battery Backup) GP5-146 / GP5B146 RAID Card (8MB Cache / Ultra2 Wide SCSI / 1chI) Only for internal array configuration GP5-143/GP5B143 12 Go to internal Hard Disk Drive (Same as SCSI configuration) System Configuration F Internal backup device Connect one backup device (Wide) DAT unit (DDS4) GP5-DT401/GP5BDT401 u Connect second backup device (Wide) 11 Tape unit (MLR3) GP5-ML301/GP5BML301 SCSI Card GP5-127/GP5B127 Two SCSI Cards (GP5-127/GP5B127) are required if two Wide connect devices are mounted. Max.2 backup devices can be Backup device (Narrow) DLT unit (DLT4000) GP5UDL201/GP5BDL201 * This device occupies two bays i DAT unit (DDS3) GP5UDT301/GP5BDT301 Tape unit (SLR5) GP5USL501/GP5BSL501 G Others y LAN Card GP5-185/GP5B185 y LAN Card GP5-183/GP5B183 One PSU can be added i Redundant Power Supply Unit GP5UPU151/GP5BUPU151 y Server Monitor Module GP5USM103/GP5BUSM103 13 System Configuration teamserver C800 series teamserver C800 series CPU: Pentium®lll (750/700/600E/550EMHz)x 1(~2) , Cache (L1+L2) : 32KB+256KB, On board SCSI, CD-ROM, Onboard LAN (Std.), Internal Hard disk bay: 4bays (3xHot-plug), Bundled SW : Servervisor/ Intel LANDesk® Server Manager, ServerWizard C885ix GP5C885 GP5C885R C880ix GP5C883 GP5C883R [Pedestal type] C880i GP5C881 GP5C881R [Rackmount type] C875ix GP5C880 GP5C880R [1CPU/Pedestal Type] 1CPU(Pentiumlll 750MHz), Memory:128MB(ECC), HDD:Option [1CPU/Rackmount Type] 1CPU(Pentiumlll 750MHz), Memory:128MB(ECC), HDD:Option [1CPU/Pedestal Type] 1CPU(Pentiumlll 700MHz), Memory:128MB(ECC), HDD:Option [1CPU/Rackmount Type] 1CPU(Pentiumlll 700MHz), Memory:128MB(ECC), HDD:Option [1CPU/Pedestal Type] 1CPU(Pentiumlll 600EMHz), Memory:128MB(ECC), HDD:Option [1CPU/Rackmount Type] 1CPU(Pentiumlll 600EMHz), Memory:128MB(ECC), HDD:Option [1CPU/Pedestal Type] 1CPU(Pentiumlll 550EMHz), Memory:128MB(ECC), HDD:Option [1CPU/Rackmount Type] 1CPU(Pentiumlll 550EMHz), Memory:128MB(ECC), HDD:Option CPU Max : 2CPUs q ® pentium ® pentium ® pentium ® pentium Memory w CPU Field Upgrade Kit (Pentium®III-750MHz (256KB) ✕1) GP5-FG20A (for C885ix) CPU Field Upgrade Kit (Pentium®III-700MHz (256KB) ✕1) GP5-FG205 (for C880ix) CPU Field Upgrade Kit (Pentium®III-600EMHz (256KB) ✕1) GP5-FG12Y (for C880i) CPU Field Upgrade Kit (Pentium®III-550EMHz (256KB) ✕1) GP5-FG11V (for C875ix) Max : 1GB Additional Memory - 64MB (64MB SDRAM-DIMM✕1) GP5-RM64F Standard memory : 128MB (128MB SDRAM-DIMM✕1) Additional Memory - 128MB (128MB SDRAM-DIMM✕1) GP5-RM12F Additional Memory - 256MB (256MB SDRAM-DIMM✕1) GP5-RM25F Internal Hard Disk Total 4 disks(3Hot Plug and 1non-Hot Plug) can be installed. Hard Disk Drive - 9GB (Ultra Wide.7,200rpm)(Hot Plug) GP5-HDH96 (1)Disk Addition to Hot Plug bays (Max . 3 disks) e Hard Disk Drive - 18GB (Ultra Wide.7,200rpm)(Hot Plug) GP5-HDH83 (2)Internal Disk Array(Maximum 3Hot Plug disks can be installed) y Hard Disk Drive - 9GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH96 RAID Card (Cache : 16MB) GP5U141 RAID Card (Cache : 8MB Internal Hard disk only) GP5-143 (3)Disk Addition to a non-Hot Plug bay GP5U831 SCSI Cable (Intl.) Hard Disk Drive - 18GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH83 only one disk can be installed e Hard Disk Drive - 9GB (7,200rpm) (non-Hot Plug) GP5-HD9G3 Hard Disk Drive - 18GB (7,200rpm) (non-Hot Plug) GP5-HD8G1 y Server Monitor Module GP5USM103 14 System Configuration Internal Devices y Tape unit GP5-ML301 SCSI Card GP5-125 r DAT unit GP5UDT301 Tape unit GP5USL501 15 System Configuration teamserver MS400 teamserver MS400 CPU: Pentium®lll (733MHz) x1 (~2) / Cache (L1+L2) : 32KB+256KB / Onboard SCSI(1xUltra160/Ultra2 Wide, 1xUltra160/Ultra2 Wide or Fast Narrow) CD-ROM / Onboard LAN(Std.) Internal Hard Disk Drive Bay:8~12(Opt.) (Hotplug) Bundled SW: Servervisor/Intel LANDesk® Server Manager/ServerWizard GP5T4A61A : [1CPU(Pentiumlll733MHz)/Pedestal Type] GP5T4A61R : [1CPU(Pentiumlll733MHz)/Rackmount Type] [Pedestal type] [Rackmount type] A <Items> CPU Field upgrade : Go to A Memory addition : Go to B Standard memory conversion : Go to C Connect HDD (Standard Drive Cage) SCSI configuration : Go to D Internal backup device : Go to E Array configuration : Go to F Internal backup device : Go to G Connect HDD (Drive Cage Conversion Kit) SCSI configuration : Go to H Internal backup device : Go to I Array configuration : Go to J Internal backup device : Go to K Others (NIC, PSU, etc.) : Go to L CPU q ® pentium CPU Field Upgrade Kit-53 (Pentiumlll 733MHz (256KB) ✕1) GP5-FG206 / GP5BFG206 Memory B Max : 4GB (1GB DIMM x 4) w Additional Memory-128MB (64MB SDRAM-DIMM✕2) GP5-RM12K/GP5BRM12K Standard : 256MB (128MB-DIMM✕2) Additional Memory-256MB (128MB SDRAM-DIMM✕2) GP5-RM25K/GP5BRM25K Additional Memory-512MB (256MB SDRAM-DIMM✕2) GP5-RM51K/GP5BRM51K Additional Memory-1GB (512MB SDRAM-DIMM✕2) GP5-RM1K/GP5BRM1K Additional Memory-2GB (1GB SDRAM-DIMM✕2) GP5-RM2K/GP5BRM2K C Standard Memory conversion option Standard Memory Conversion Kit-512MB (256MB to 512MB) GP5BRU51G w Standard Memory Conversion Kit-1GB (256MB to 1GB) GP5BRU1GD Standard Memory Conversion Kit-2GB (256MB to 2GB) GP5BRU2GB Internal HDD/Internal backup device Standard Drive Cage 1inch/1.6inch height HDD x 8 D (Ultra160/Ultra2 Wide SCSI Configuration) Hard Disk Drive-9GB (Ultra2 Wide SCSI, 7,200rpm) 1"height/Hotplug GP5-HDH99/GP5BHDH99 e To comprise Ultra160 configuration, GP5-HDH9A/GP5BHDH9A, GP5-HDH87/GP5BHDH87 and GP5-HDH62/GP5BHDH62 must be used. Hard Disk Drive-18GB (Ultra2 Wide SCSI, 7,200rpm) 1"height/Hotplug GP5-HDH86/GP5BHDH86 Hard Disk Drive-9GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1"height/Hotplug GP5-HDH9A/GP5BHDH9A Hard Disk Drive-18GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1"height/Hotpluhg GP5-HDH87/GP5BHDH87 Hard Disk Drive-36GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1.6"height/Hotplug GP5-HDH62/GP5BHDH62 *Cannot be mounted when Drive Cage Conversion Kit (GP5BBU1) is applied 16 System Configuration E Backup device (Narrow) DLT unit (DLT4000) GP5UDL201/GP5BDL201 * Two 5"bays are occupied r DAT unit (DDS3) GP5UDT301/GP5BDT301 SCSI Card GP5-127/GP5B127 SCSI Cable GP5-842/GP5B842 SCSI Card (GP5-127/GP5B127) and SCSI Cable (GP5-842/GP5B842) are required if both Narrow connect device and Wide connect device are mounted. (In case that Onboard WideA channel is connected for device) Tape unit GP5USL501/GP5BSL501 Max.2 backup devices can be mounted Connect one backup device (Wide) DLT unit (DLT7000) GP5-DL351/GP5BDL351 * Two 5"bays are occupied r Connect second backup device (Wide) y DAT unit (DDS4) GP5-DT401/GP5BDT401 SCSI Card GP5-127/GP5B127 Tape unit (MLR3) GP5-ML301/GP5BML301 SCSI Card (GP5-127/GP5B127) is required in each case as below: 1)Two Wide connect devices are installed. (SCSI Card is required for secondary device) 2)Both Narrow connect device and Wide connect device are mounted. (In case that Onboard Narrow channel is connected for device) (Array Configuration) F RAID Card (32MB Cache / Ultra2 Wide SCSI / 3ch) GP5-144 / GP5B144 y Go to Hard Disk Drive as above RAID Card (16MB Cache / Ultra2 Wide SCSI / 2ch) GP5-146 / GP5B146 RAID Card (8MB Cache / Ultra2 Wide SCSI / 1ch) GP5-143/GP5B143 Only for internal array configuration Cannot be used when Drive Cage Conversion Kit (GP5BBU1) is applied. G Backup device (Narrow) DLT unit (DLT4000) GP5UDL201/GP5BDL201 * Two 5"bays are occupied r DAT unit (DDS3) GP5UDT301/GP5BDT301 SCSI Card GP5-127/GP5B127 SCSI Cable GP5-842/GP5B842 SCSI Card (GP5-127/GP5B127) and SCSI Cable (GP5-842/GP5B842) are required if both Narrow connect device and Wide connect device are mounted. (In case that Onboard WideA channel is connected for device) Tape unit GP5USL501/GP5BSL501 Max.2 backup devices can be mounted Connect one backup device (Wide) DLT unit (DLT7000) GP5-DL351/GP5BDL351 * Two 5"bays are occupied r Connect second backup device (Wide) y DAT unit (DDS4) GP5-DT401/GP5BDT401 SCSI Card GP5-127/GP5B127 Tape unit (MLR3) GP5-ML301/GP5BML301 SCSI Card (GP5-127/GP5B127) is required in each case as below: 1)Two Wide connect devices are installed. (SCSI Card is required for secondary device) 2)Both Narrow connect device and Wide connect device are mounted. (In case that Onboard Narrow channel is connected for device) 17 System Configuration (When Drive Cage Conversion Kit is used) Drive Cage Conversion Kit (for CTO only) (HDD Bay: 8bays to 12bays) GP5BBU1 *When using this option, Only 1"height HDD can be mounted. (An additional PSU is required if Drive Cage Conversion Kit is applied.) H e (Ultra 160/Ultra2 Wide SCSI Configuration) Hard Disk Drive-9GB (Ultra2 Wide SCSI, 7,200rpm) 1"height/Hotplug GP5-HDH99/GP5BHDH99 Hard Disk Drive-18GB (Ultra2 Wide SCSI, 7,200rpm) 1"height/Hotplug GP5-HDH86/GP5BHDH86 Hard Disk Drive-9GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1"height/Hotplug GP5-HDH9A/GP5BHDH9A Hard Disk Drive-18GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1"height/Hotpluhg GP5-HDH87/GP5BHDH87 1.6" 36GB HDD(GP5BHDH62) cannot be mounted in Drive Cage Conversion Kit (GP5BBU1). I Backup device (Narrow) DLT unit (DLT4000) GP5UDL201/GP5BDL201 * Two 5"bays are occupied r SCSI Card GP5-127/GP5B127 SCSI Cable GP5-842/GP5B842 DAT unit (DDS3) GP5UDT301/GP5BDT301 Tape unit GP5USL501/GP5BSL501 Max.2 backup devices can be mounted Backup device (Wide) DLT unit (DLT7000) GP5-DL351/GP5BDL351 * This device occupies two bays y SCSI Card GP5-127/GP5B127 DAT unit (DDS4) GP5-DT401/GP5BDT401 Tape unit (MLR3) GP5-ML301/GP5BML301 (Array configuration) J y RAID Card (32MB Cache/Ultra2 Wide SCSI/3ch) GP5-144/GP5B144 Go to Hard Disk Drive as above RAID Card (16MB Cache/Ultra2 Wide SCSI/2ch) GP5-146/GP5B146 GP5-143/GP5B143 cannot be used with Drive Cage Conversion Kit (GP5BBU1). 18 System Configuration K Backup device (Narrow) DLT unit (DLT4000) GP5UDL201/GP5BDL201 * Two 5"bays are occupied r DAT unit (DDS3) GP5UDT301/GP5BDT301 SCSI Card GP5-127/GP5B127 SCSI Cable GP5-842/GP5B842 SCSI Card (GP5-127/GP5B127) and SCSI Cable (GP5-842/GP5B842) are required if both Narrow connect device and Wide connect device are mounted. (In case that Onboard WideA channel is connected for device) Tape unit GP5USL501/GP5BSL501 Max.2 backup devices can be mounted Connect one Backup device (Wide) DLT unit (DLT7000) GP5-DL351/GP5BDL351 * Two 5"bays are occupied r Connect secondary Backup device (Wide) y DAT unit (DDS4) GP5-DT401/GP5BDT401 SCSI Card GP5-127/GP5B127 Tape unit (MLR3) GP5-ML301/GP5BML301 SCSI Card (GP5-127/GP5B127) is required in case as below: 1) Both Narrow connect device and Wide connect device are mounted. (In case that Onboard WideA channel is connected for device) 2) Two SCSI Cards are required if two Wide connect devices are mounted. L Others y LAN Card GP5-185/GP5B185 y LAN Card GP5-183/GP5B183 o Redundant Power Supply Unit GP5UPU161/GP5BUPU161 An additional PSU is required when Drive Cage Conversion Kit (GP5BBU1) is used 19 System Configuration teamserver G800i series (Jan.1999) teamserver G800 series CPU: Pentium®lll (750/700/600E/550MHz) x 1(~2) , Cache (L1+L2) : 32KB+256KB, On board SCSI, CD-ROM, Onboard LAN (Std.), Internal Hard disk bay: 8bays (Hot-plug), Servervisor/ Intel LANDesk® Server Manager, Server Wizard G885ix GP5G885L GP5G885LR G880ix GP5G883L [Pedestal type] GP5G883LR G880i GP5G881L GP5G881LR G875ix [Rackmount type] GP5G880L GP5G880LR CPU [1CPU/Pedestal Type] 1CPU(Pentiumlll 750MHz), Memory:256MB(ECC), HDD:Option [1CPU/Rackmount Type] 1CPU(Pentiumlll 750MHz), Memory:256MB(ECC), HDD:Option [1CPU/Pedestal Type] 1CPU(Pentiumlll 700MHz), Memory:256MB(ECC), HDD:Option [1CPU/Rackmount Type] 1CPU(Pentiumlll 700MHz), Memory:256MB(ECC), HDD:Option [1CPU/Pedestal Type] 1CPU(Pentiumlll 600EMHz), Memory:256MB(ECC), HDD:Option [1CPU/Rackmount Type] 1CPU(Pentiumlll 600EMHz), Memory:256MB(ECC), HDD:Option [1CPU/Pedestal Type] 1CPU(Pentiumlll 550EMHz), Memory:256MB(ECC), HDD:Option [1CPU/Rackmount Type] 1CPU(Pentiumlll 550EMHz), Memory:256MB(ECC), HDD:Option ® CPU Field Upgrade Kit (Pentium®III-750MHz (256KB) ✕1) GP5-FG20A (for G885ix) ® CPU Field Upgrade Kit (Pentium®III-700MHz (256KB) ✕1) GP5-FG205 (for G880ix) ® CPU Field Upgrade Kit (Pentium®III-600EMHz (256KB) ✕1) GP5-FG12Y (for G880i) ® CPU Field Upgrade Kit (Pentium®III-550EMHz (256KB) ✕1) GP5-FG11V (for G875ix) Max : 2CPUs q pentium pentium pentium pentium Memory w Max : 2GB Additional Memory - 64MB (64MB SDRAM-DIMM✕1) GP5-RM64F Standard memory : 256MB (256MB SDRAM-DIMM✕1) Additional Memory - 128MB (128MB SDRAM-DIMM✕1) GP5-RM12F Additional Memory - 256MB (256MB SDRAM-DIMM✕1) GP5-RM25F Additional Memory - 512MB (512MB SDRAM-DIMM✕1) GP5-RM51F Internal Hard Disk (1)Disk Addition / Duplexing e Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH96 ❋Up to 8 disks in a teamserver Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH83 (2)Internal Disk Array y Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH96 RAID Card (Cache : 16MB, Ultra Wide SCSI) GP5U141 RAID Card (Cache : 4MB, Internal use only) GP5U142 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH83 RAID Card (Cache : 32MB, Ultra2 Wide SCSI, BBU) GP5-144 RAID Card (Cache : 16MB, Ultra2 Wide SCSI, BBU) GP5-146 y Server Monitor Module GP5USM103 Redundant Power Supply Unit GP5UPU131 i NOTE : 2 PSUs are required if GP5-DL351 is installed Maximum 3PSUs can be installed in G800i series. 20 System Configuration Internal Devices DLT unit *(Occupied two 5" bay slots) GP5-DL351 Only G800i y SCSI Card GP5-127 Tape unit GP5-ML301 r DLT unit (Occupied two 5" bay slots) GP5UDL201 *NOTE : 2 PSUs are required as standard if GP5DL351 is installed DAT unit GP5UDT301 Maximum 3PSUs can be installed in G800i series. Tape unit GP5USL501 Tape unit GP5-NS201 21 System Configuration teamserver MS600 teamserver MS600 CPU: Pentium®lll (550MHz) x1 (~4) / Cache (L1+L2) : (32KB+2MB/1MB/512KB)/Onboard SCSI(Ultra2 Widex2, Fast Narrowx1) CD-ROM/LAN Card(Std.)/Internal Hard Disk Drive Bay:8~12(Opt.) (Hotplug) Bundled SW:Servervisor/Intel LANDesk® Server Manager/ServerWizard GP5T6A31A : [1CPU(Pentiumlll550MHz/2MB)/Pedestal Type] GP5T6A31R : [1CPU(Pentiumlll550MHz/2MB)/Rackmount Type] GP5T6A21A : [1CPU(Pentiumlll550MHz/1MB)/Pedestal Type] GP5T6A21R : [1CPU(Pentiumlll550MHz/1MB)/Rackmount Type] GP5T6A11A : [1CPU(Pentiumlll550MHz/512KB)/Pedestal Type] GP5T6A11R : [1CPU(Pentiumlll550MHz/512KB)/Rackmount Type] [Pedestal type] [Rackmount type] A <Items> CPU Field upgrade : Go to A Memory addition : Go to B Standard memory conversion : Go to C Connect HDD (Standard Drive Cage) SCSI configuration : Go to D Internal backup device : Go to E Array configuration : Go to F Internal backup device : Go to G Connect HDD (Drive Cage Conversion Kit) SCSI configuration : Go to H Internal backup device : Go to I Array configuration : Go to J Internal backup device : Go to K Others (NIC, PSU, etc.) : Go to L CPU CPU Field Upgrade Kit (Pentiumlll Xeon 550MHz (2MB) ✕1) GP5-FG203/GP5BFG203 q CPU Field Upgrade Kit (Pentiumlll Xeon 550MHz (1MB) ✕1) GP5-FG202/GP5BFG202 CPU Field Upgrade Kit (Pentiumlll Xeon 550MHz (512KB) ✕1) GP5-FG201/GP5BFG201 Memory B Max:4GB (1GB DIMMx4) w Additional Memory-128MB (32MB EDO-DIMM✕4) GP5-RM12G/GP5BRM12G Standard:256MB (64MB-DIMM✕4) Additional Memory-256MB (64MB EDO-DIMM✕4) GP5-RM25G/GP5BRM25G Additional Memory-512MB (128MB EDO-DIMM✕4) GP5-RM51G/GP5BRM51G Additional Memory-1GB (256MB EDO-DIMM✕4) GP5-RM1G/GP5BRM1G C Standard Memory conversion option Standard Memory Conversion Kit-512MB (128MB EDO-DIMM✕4) GP5BRU51B w Standard Memory Conversion Kit-1GB (256MB EDO-DEMM✕4) GP5BRU1GB Internal HDD/Internal backup device (Standard drive cage) Standard Drive Cage 1inch/1.6inch height HDD x 8 D e y (SCSI Configuration) (Ultra2 Wide SCSI) Hard Disk Drive-9GB (Ultra2 Wide SCSI, 7,200rpm) 1"height/Hotplug GP5-HDH97/GP5BHDH97 (Ultra160 SCSI) Hard Disk Drive-18GB (Ultra2 Wide SCSI, 7,200rpm) 1"height/Hotplug GP5-HDH84/GP5BHDH84 SCSI Card GP5-128/GP5B128 Hard Disk Drive-9GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1"height/Hotplug GP5-HDH9A/GP5BHDH9A To comprise Ultra160 configuration, GP5-HDH9A/GP5BHDH9A GP5-HDH87/GP5BHDH87 GP5-HDH62/GP5BHDH62 must be used. Hard Disk Drive-18GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1"height/Hotplug GP5-HDH87/GP5BHDH87 Hard Disk Drive-36GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1.6"height/Hotplug GP5-HDH62/GP5BHDH62 22 System Configuration Connect one backup device (Wide) E DLT unit (DLT7000) GP5-DL351/GP5BDL351 * Two 5"bays are occupied r Connect second backup device (Wide) y DAT unit (DDS4) GP5-DT401/GP5BDT401 SCSI Card GP5-127/GP5B127 SCSI Card (GP5-127/GP5B127) is required to connect backup device (Wide) in case of Ultra160 configuration (Using GP5-128/GP5B128). * Two GP5-127/GP5B127 are required when two Wideconnect devices are mounted. Tape unit (MLR3) GP5-ML301/GP5BML301 Max.2 backup devices can be mounted Backup device(Narrow) DLT unit (DLT4000) GP5UDL201/GP5BDL201 * Two 5"bays are occupied r DAT unit (DDS3) GP5UDT301/GP5BDT301 Tape unit GP5USL501/GP5BSL501 (Array Configuration) F RAID Card (32MB Cache/Ultra2 Wide SCSI) GP5-144/GP5B144 y Go to Hard Disk Drive as above RAID Card (16MB Cache/Ultra2 Wide SCSI) GP5-146/GP5B146 Bbackup device (Wide) G DLT unit (DLT7000) GP5-DL351/GP5BDL351 * Two 5"bays are occupied r DAT unit (DDS4) GP5-DT401/GP5BDT401 SCSI Card GP5-127/GP5B127 SCSI Card (GP5-127/GP5B127) is required in case of two backup device (Wide) are connected. (The SCSI Card is used for connecting secondary device) Tape unit (MLR3) GP5-ML301/GP5BML301 Max.2 backup devices can bemounted Backup device (Narrow) DLT unit (DLT4000) GP5UDL201/GP5BDL201 * Two 5"bays are occupied r DAT unit (DDS3) GP5UDT301/GP5BDT301 Tape unit GP5USL501/GP5BSL501 (When Drive Cage Conversion Kit is used) Drive Cage Conversion Kit (for CTO only) (HDD Bay: 8bays to 12bays) GP5BBU1 *When using this option, Only 1"height HDD can be mounted. H (SCSI Conflguration) (Ultra2 Wide SCSI) Hard Disk Drive-9GB (Ultra2 Wide SCSI, 7,200rpm) 1"height/Hotplug GP5-HDH97/GP5BHDH97 e (Ultra160 SCSI) y SCSI Card GP5-128/GP5B128 * Two GP5-128 are required, in case of using Drive Cage Conversion Kit. Hard Disk Drive-18GB (Ultra2 Wide SCSI, 7,200rpm) 1"height/Hotplug GP5-HDH84/GP5BHDH84 Hard Disk Drive-9GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1"height/Hotplug GP5-HDH9A/GP5BHDH9A Hard Disk Drive-18GB (Ultra160/Ultra2 Wide SCSI, 10,000rpm) 1"height/Hotplug GP5-HDH87/GP5BHDH87 23 System Configuration Backup device (Wide) I DLT unit (DLT7000) GP5-DL351/GP5BDL351 * Two 5"bays are occupied r SCSI Card GP5-127/GP5B127 DAT unit (DDS4) GP5-DT401/GP5BDT401 * Two SCSI Cards (GP5-127/GP5B127) are required for connecting two Wide connect backup devices Tape unit (MLR3) GP5-ML301/GP5BML301 Max.2 backup devices can be mounted Backup device(Narrow) DLT unit (DLT4000) GP5UDL201/GP5BDL201 * Two 5"bays are occupied r DAT unit (DDS3) GP5UDT301/GP5BDT301 Tape unit GP5USL501/GP5BSL501 (Array configuration) J RAID Card (32MB Cache/Ultra2 Wide SCSI/3ch) GP5-144/GP5B144 RAID Card (16MB Cache/Ultra2 Wide SCSI/2ch) GP5-146/GP5B146 y Go to Internal Hard Disk Drive (Same as SCSI configuration) Backup device (Wide) K DLT unit (DLT7000) GP5-DL351/GP5BDL351 * Two 5"bays are occupied r DAT unit (DDS4) GP5-DT401/GP5BDT401 SCSI Card GP5-127/GP5B127 SCSI Card (GP5-127/GP5B127) is required in case of two backup devices (Wide) are connected. (The SCSI Card is used for connecting secondary device) Tape unit (MLR3) GP5-ML301/GP5BML301 Max.2 backup devices can be mounted Backup device(Narrow) DLT unit (DLT4000) GP5UDL201/GP5BDL201 * Two 5"bays are occupied r DAT unit (DDS3) GP5UDT301/GP5BDT301 Tape unit GP5USL501/GP5BSL501 L Others LAN Card GP5-185/GP5B185 y y o LAN Card GP5-183/GP5B183 One PSU can be added Redundant Power Supply Unit GP5UPU161/GP5BUPU161 Server Monitor Module GP5USM103/GP5BUSM103 y 24 System Configuration teamserver HS900 teamserver HS900 series CPU: Pentium®lll Xeon™ (550MHz) x 2(~8) , Cache (L1+L2) : 32KB+2MB/1MB, Internal Hard disk bay:(Hot-plug) 2bays, 2 x Ultra2 Wide SCSI Onboard, 2ch RAID Card, CD-ROM, LAN Card (Std.), Redundant Power Supply (Std.)/FAN (Std.), Intel LANDesk® Server Manager/Servervisor, ServerWizard GP5T9A32R [Rackmount Type] 2 x Pentium®lll Xeon™ 550MHz(2MB), Memory:1GB(ECC), HDD:Option GP5T9A22R [Rackmount Type] 2 x Pentium®lll Xeon™ 550MHz(1MB), Memory:1GB(ECC), HDD:Option [Rackmount type] CPU Max : 8CPUs Standard : 2CPUs q CPU Field Upgrade Kit (Pentium®III Xeon™-550MHz (2MB) ✕1) GP5-FG203T CPU Field Upgrade Kit (Pentium®III Xeon™-550MHz (1MB) ✕1) GP5-FG202T Memory w Max. memory: 32GB Additional Memory - 256MB (128MB-DIMM✕2) GP5-RM25J Standard memory : 1GB (128MB-DIMM✕8) w Additional Memory - 512MB (256MB-DIMM✕2) GP5-RM51J Additiond Memory Board GP5-RB201 Additional Memory - 1024MB (512MB-DIMM✕2) GP5-RM1J Internal Hard Disk Up to two HDDs can be mounted in the main unit Additional Memory - 2048MB (1024MB-DIMM✕2) GP5-RM2J Max : 2 SCSI on board Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH98T e y Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH85T RAID Card (GP5-146 : std.) Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH61T Connect with Storage System Max : 8 y SCSI Card (Ultra2 Wide) GP5-127 SCSI Cable(3m) GP5MU823A Storage System GP5UR1DC4 Max : 1 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH9A Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH87 Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH62 SCSI Cable(5m) GP5S-833 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH97 SCSI Cable(10m) GP5S-834 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH84 Redundant Power Supply Unit GP5U R1PU1 25 System Configuration Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH9A y RAID Card (Cache : 32MB Ultra2 Wide SCSI) GP5-144 SCSI Cable GP5S-832 Storage System GP5UR1DC4 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH87 Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH62 SCSI Cable GP5S-835 RAID Card (Cache : 16MB Ultra2 Wide SCSI) GP5-146 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH97 SCSI Cable GP5S-836 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH84 y Server Monitor Module GP5USM103 Internal Devices Up to four Tape units can be mounted o Backup Cabinet GP5UR1BC1 SCSI Cable GP5S-832 DLT unit (Occupied two 5" bay slots) GP5-DL351 Tape unit GP5-ML301 DLT unit (Occupied two 5" bay slots) GP5UDL201 DAT unit GP5UDT301 Tape unit GP5USL501 Redundant Power Supply Unit GP5UPU151 26 System Configuration teamserver External Devices (Pedestal only) MS600 MS400 ES200 ES300 G800 C800 Hard disk cabinet Disk addition y C800 only SCSI card GP5-125 SCSI cable GP5MU823A RAID card(cache:16MB) GP5U141 SCSI cable GP5MU829A SCSI card GP5-127 SCSI cable GP5MU823A RAID card(cache:32MB) GP5-144 SCSI cable GP5S-832 RAID card(cache:16MB) GP5-146 SCSI cable GP5S-832 Disk array y Disk addition y y y Hard disk cabinet GP5MS622A G800 only Disk array y y G800 only Disk array y y y G800 only Configuration of the inside Hard disk cabinet Hard Disk Drive-9GB (7,200rpm) GP5-HDH97 Hard Disk Drive-18GB (10,000rpm) GP5-HDH87 Hard Disk Drive-9GB (10,000rpm) GP5-HDH9A Hard Disk Drive-36GB (10,000rpm) GP5-HDH62 Hard Disk Drive-18GB (7,200rpm) GP5-HDH84 Power Supply Unit GP5URIPU1 27 System Configuration teamserver Rackmount 40U Rack GP5-R1RC4 40U Rack & Rack Coupling kit GP5-R1RC5 24U Rack GP5-R2RC1 ❋A maximum of two servers can be installed in a, 40U Rack system. ❋The Rack Coupling kit is used for connecting two Racks together. 24U Rack & Rack Coupling kit GP5-R2RC2 Component Shelf GP5-R1TB4 Keyboard/Monitor Shelf Kit GP5-R1TB5(for GP5R2RC1/GP5-R1RC4) teamserver CPU nodes for Rackmount Keyboard/Monitor Extention Cables GP5-411 Key board/Monitor Enhanced Switch GP5-SB101 Enhanced keyboard GP5-R1KB2 – Each GP5-411 is reguired for each CPU node. – One GP5-SB101 is used for max. 4 CPU nodes. HS900 MS600 MS400 ES300 G800 C800 y C800 Only SCSI Card GP5-125 Storage System GP5UR1DC4 SCSI Cable GP5MU823A y RAID Card❋ GP5U141 y y G 800 Only y SCSI Card GP5-127 SCSI Cable GP5MU823A/GP5S-833/834 y G 800 Only y SCSI Cable GP5MU829A RAID Card GP5-144 SCSI Cable GP5S-832/835/836 y RAID Card GP5-146 G 800 Only SCSI Cable GP5S-832/835/836 ❋GP5U141 can be used for Hard disk cabinet only when GP5U142 (G800) / GP5-143 (C800) is used to connect internal hard disk array. [Inside of Storage System] Hard Disk Drive-9GB(7,200rpm) GP5-HDH97 Hard Disk Drive-18GB(10,000rpm) GP5-HDH87 Hard Disk Drive-9GB(10,000rpm) GP5-HDH9A Hard Disk Drive-36GB(10,000rpm) GP5-HDH62 Hard Disk Drive-18GB(7,200rpm) GP5-HDH84 Redundant Power Supply Unit GP5UR1PU1 NOTE : A maximum of eight Hard Disk Drives can be installed in a Storage System. In a RAID configuration, a physical pack must be comprised of the same type of Hard disks. 28 teamserver Hardware Product teamserver HS900 Product ID GP5T9A32R Remarks Pentium lll Xeon 550MHz with 2MB Cache (x2, up to 8CPUs) , 1GB SDRAM-DIMM(128MBx8) with ECC ( 32GB maximum ) (Rackmount) # of HDD Bay: 2(Hotplug) [Up to twelve Storage System(GP5UR1DC4) can be mounted as external storage]/32Xspeed CD- (End Nov 1999) ROM /LAN Card(Std.) Onboard SCSI:Ultra2 Widex2/Redundant&Hotplug PSU(Std.), Redundant&Hotplug&Proactive Fan(Std.)/Rackmount7U Servervisor/LANDesk Server Manager/Server Wizard teamserver HS900 GP5T9A22R Pentium lll Xeon 550MHz with 1MB Cache (x2, up to 8CPUs) , 1GB SDRAM-DIMM(128MBx8) with ECC ( 32GB maximum ) (Rackmount) # of HDD Bay: 2(Hotplug) [Up to twelve Storage System(GP5UR1DC4) can be mounted as external storage]/32Xspeed CD- (End Nov 1999) ROM /LAN Card(Std.) Onboard SCSI:Ultra2 Widex2/Redundant&Hotplug PSU(Std.), Redundant&Hotplug&Proactive Fan(Std.)/Rackmount7U Servervisor/LANDesk Server Manager/Server Wizard teamserverMS600 GP5T6A31A Pentium lll Xeon 550MHz with 2MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM(64MBx4) with ECC,50ns ( 4GB (Pedestal) maximum ) (Beg Mar 2000) # of HDD Bay: 8(Hotplug) [12(Hotplug): With drive cage conversion (GP5BBU1)]/32Xspeed CD-ROM /LAN Card(Std.) Onboard SCSI:Ultra2 Widex2, Narrowx1/Ultra160 is available[SCSI Card(GP5-128/GP5B128) is required] Redundant&Hotplug PSU(Opt.)/Redundant&Hotplug&Proactive Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverMS600 GP5T6A31R Pentium lll Xeon 550MHz with 2MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM(64MBx4) with ECC,50ns ( 4GB (Rackmount) maximum ) (Beg Mar 2000) # of HDD Bay: 8(Hotplug) [12(Hotplug): With drive cage conversion (GP5BBU1)]/32Xspeed CD-ROM /LAN Card(Std.) Onboard SCSI:Ultra2 Widex2, Narrowx1/Ultra160 is available[SCSI Card(GP5-128/GP5B128) is required] Redundant&Hotplug PSU(Opt.)/Redundant&Hotplug&Proactive Fan(Std.)/Rackmount 7U Servervisor/LANDesk Server Manager/Server Wizard teamserverMS600 GP5T6A21A Pentium lll Xeon 550MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM(64MBx4) with ECC,50ns ( 4GB (Pedestal) maximum ) (Beg Mar 2000) # of HDD Bay: 8(Hotplug) [12(Hotplug): With drive cage conversion (GP5BBU1)]/32Xspeed CD-ROM /LAN Card(Std.) Onboard SCSI:Ultra2 Widex2, Narrowx1/Ultra160 is available[SCSI Card(GP5-128/GP5B128) is required] Redundant&Hotplug PSU(Opt.)/Redundant&Hotplug&Proactive Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverMS600 GP5T6A21R Pentium lll Xeon 550MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM(64MBx4) with ECC,50ns ( 4GB (Rackmount) maximum ) (Beg Mar 2000) # of HDD Bay: 8(Hotplug) [12(Hotplug): With drive cage conversion (GP5BBU1)]/32Xspeed CD-ROM /LAN Card(Std.) Onboard SCSI:Ultra2 Widex2, Narrowx1/Ultra160 is available[SCSI Card(GP5-128/GP5B128) is required] Redundant&Hotplug PSU(Opt.)/Redundant&Hotplug&Proactive Fan(Std.)/Rackmount 7U Servervisor/LANDesk Server Manager/Server Wizard teamserverMS600 GP5T6A11A Pentium lll Xeon 550MHz with 512KB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM(64MBx4) with ECC,50ns ( 4GB (Pedestal) maximum ) (Beg Mar 2000) # of HDD Bay: 8(Hotplug) [12(Hotplug): With drive cage conversion (GP5BBU1)]/32Xspeed CD-ROM /LAN Card(Std.) Onboard SCSI:Ultra2 Widex2, Narrowx1/Ultra160 is available[SCSI Card(GP5-128/GP5B128) is required] Redundant&Hotplug PSU(Opt.)/Redundant&Hotplug&Proactive Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverMS600 GP5T6A11R Pentium lll Xeon 550MHz with 512KB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM(64MBx4) with ECC,50ns ( 4GB (Rackmount) maximum ) (Beg Mar 2000) # of HDD Bay: 8(Hotplug) [12(Hotplug): With drive cage conversion (GP5BBU1)]/32Xspeed CD-ROM /LAN Card(Std.) Onboard SCSI:Ultra2 Widex2, Narrowx1/Ultra160 is available[SCSI Card(GP5-128/GP5B128) is required] Redundant&Hotplug PSU(Opt.)/Redundant&Hotplug&Proactive Fan(Std.)/Rackmount 7U Servervisor/LANDesk Server Manager/Server Wizard teamserverMS400 GP5T4A61A Pentium lll733MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (128MB x2) with ECC (4GB maximum) (Pedestal) # of HDD Bay: 8(Hotplug) [12(Hotplug): With drive cage conversion (GP5BBU1)]/40Xspeed CD-ROM /Onboard LAN (Beg Mar 2000) Onboard SCSI:Ultra160/Ultra2 Widex1, Ultra160/Ultra2 Wide or Fast Narrowx1/Redundant&Hotplug PSU(Opt.), Redundant&Hotplug&Proactive Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard 29 teamserver Hardware Product teamserverMS400 Product ID GP5T4A61R Remarks Pentium lll733MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (128MB x2) with ECC (4GB maximum) (Rackmount) # of HDD Bay: 8(Hotplug) [12(Hotplug): With drive cage conversion (GP5BBU1)]/40Xspeed CD-ROM /Onboard LAN (Beg Mar 2000) Onboard SCSI:Ultra160/Ultra2 Widex1, Ultra160/Ultra2 Wide or Fast Narrowx1/Redundant&Hotplug PSU(Opt.), Redundant&Hotplug&Proactive Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverES300 GP5T3A61A Pentium lll733MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (128MBx2) with ECC, (4GB maximum ) (Pedestal) # of HDD Bay: 5(Hotplug)/40Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra160/Ultra2 Widex1, Ultra160/Ultra2 Wide (Beg Mar 2000) or Fast Narrowx1 Redundant&Hotplug PSU(Opt.), Redundant&Hotplug&Proacitve Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverES300 GP5T3A61R Pentium lll733MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (128MBx2) with ECC, (4GB maximum ) (Rackmount) # of HDD Bay: 5(Hotplug)/40Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra160/Ultra2 Widex1, Ultra160/Ultra2 Wide (Beg Mar 2000) or Fast Narrowx1 Redundant&Hotplug PSU(Opt.), Redundant&Hotplug&Proacitve Fan(Std.)/Rackmount4U Servervisor/LANDesk Server Manager/Server Wizard teamserverES200 GP5T2A51A (End Feb 2000) Pentium lll700MHz with 256KB Cache (x1) , 128MB SDRAM (128MBx1) with ECC (768MB maximum ) # of HDD Bay: 4(Non hotplug)[2xSCSI Bay(Use one 5"Bay) + 2xSCSI bay(SCSI/EIDE HDD both can be mounted) 40Xspeed CD-ROM /Onboard LAN/Proactive Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverES200 GP5T2AY1A (End Feb 2000) Pentium lll600EMHz with 256KB Cache (x1) , 128MB SDRAM (128MBx1) with ECC (768MB maximum ) # of HDD Bay: 4(Non hotplug)[2xSCSI Bay(Use one 5"Bay) + 2xSCSI bay(SCSI/EIDE HDD both can be mounted) 40Xspeed CD-ROM /Onboard LAN/Proactive Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverES200 GP5T2AV1A (End Feb 2000) Pentium lll550EMHz with 256KB Cache (x1) , 128MB SDRAM (128MBx1) with ECC (768MB maximum ) # of HDD Bay: 4(Non hotplug)[2xSCSI Bay(Use one 5"Bay) + 2xSCSI bay(SCSI/EIDE HDD both can be mounted) 40Xspeed CD-ROM /Onboard LAN/Proactive Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverES200 GP5T2A81A (End Feb 2000) Celeron466MHz with 128KB Cache (x1) , 128MB SDRAM (128MBx1) with ECC (768MB maximum ) # of HDD Bay: 4(Non hotplug)[2xSCSI Bay(Use one 5"Bay) + 2xSCSI bay(SCSI/EIDE HDD both can be mounted) 40Xspeed CD-ROM /Onboard LAN/Proactive Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverG885ix GP5G885L (Beg Feb 2000) Pentium lll750MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x2) with ECC (2GB maximum) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2 Widex1, Ultra2 Wide or Fast Narrowx1 /Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverG885ix GP5G885LR Pentium lll750MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MBx1) with ECC (2GB maximum) (Rackmount) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2 Widex1, Ultra2 Wide or Fast Narrowx1 (Beg Feb 2000) /Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)/Rackmount7U Servervisor/LANDesk Server Manager/Server Wizard teamserverG880ix GP5G883L (Beg Jan 2000) Pentium lll700MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2 Widex1, Ultra2 Wide or Fast Narrowx1 /Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverG880ix GP5G883LR Pentium lll700MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum) (Rackmount) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2 Widex1, Ultra2 Wide or Fast Narrowx1 (Beg Jan 2000) /Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)/Rackmount7U Servervisor/LANDesk Server Manager/Server Wizard 30 teamserver Hardware Product teamserverG880i Product ID GP5G881L (Beg Feb 2000) Remarks Pentium lll600EMHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2 Widex1, Ultra2 Wide or Fast Narrowx1 /Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverG880i GP5G881LR Pentium lll600EMHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum) (Rackmount) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2 Widex1, Ultra2 Wide or Fast Narrowx1 (Beg Feb 2000) /Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)/Rackmount7U Servervisor/LANDesk Server Manager/Server Wizard teamserverG875i GP5G880L (Beg Feb 2000) Pentium lll550EMHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2 Widex1, Ultra2 Wide or Fast Narrowx1 /Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.) Servervisor/LANDesk Server Manager/Server Wizard teamserverG875i GP5G880LR Pentium lll550EMHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum) (Rackmount) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2 Widex1, Ultra2 Wide or Fast Narrowx1 (Beg Feb 2000) /Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)/Rackmount7U Servervisor/LANDesk Server Manager/Server Wizard teamserverC885ix GP5C885 (Beg Feb 2000) Pentium lll750MHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MBx1) with ECC, (1GB maximum ) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra Widex1, Ultra Wide or Fast Narrowx1 Servervisor/LANDesk Server Manager/Server Wizard teamserverC885ix GP5C885R Pentium lll750MHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MBx1) with ECC, (1GB maximum ) (Rackmount) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra Widex1, Ultra Wide or Fast (Beg Feb 2000) Narrowx1/Rackmount6U Servervisor/LANDesk Server Manager/Server Wizard teamserverC880ix GP5C883 (Beg Jan 2000) Pentium lll700MHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MBx1) with ECC, (1GB maximum ) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra Widex1, Ultra Wide or Fast Narrowx1 Servervisor/LANDesk Server Manager/Server Wizard teamserverC880ix GP5C883R Pentium lll700MHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MBx1) with ECC, (1GB maximum ) (Rackmount) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra Widex1, Ultra Wide or Fast (Beg Jan 2000) Narrowx1/Rackmount6U Servervisor/LANDesk Server Manager/Server Wizard teamserverC880i GP5C881 (Beg Feb 2000) Pentium lll600EMHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MBx1) with ECC, (1GB maximum ) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra Widex1, Ultra Wide or Fast Narrowx1 Servervisor/LANDesk Server Manager/Server Wizard teamserverC880i GP5C881R Pentium lll600EMHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MBx1) with ECC, (1GB maximum ) (Rackmount) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra Widex1, Ultra Wide or Fast (Beg Feb 2000) Narrowx1/Rackmount6U Servervisor/LANDesk Server Manager/Server Wizard teamserverC875i GP5C880 (Beg Feb 2000) Pentium lll550EMHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MBx1) with ECC, (1GB maximum ) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra Widex1, Ultra Wide or Fast Narrowx1 Servervisor/LANDesk Server Manager/Server Wizard teamserverC875i GP5C880R Pentium lll550EMHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MBx1) with ECC, (1GB maximum ) (Rackmount) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra Widex1, Ultra Wide or Fast (Beg Feb 2000) Narrowx1/Rackmount6U Servervisor/LANDesk Server Manager/Server Wizard 31 teamserver Hardware G800i ES300 C800i ES200 GP5-FG205 CPU Field Upgrade Kit-57 GP5-FG12Y CPU Field Upgrade Kit-60 GP5-FG11V Additional Memory 2GB GP5-RM2J ■ ■ SDRAM-DIMM (100MHz) 1024MBx2 Additional Memory 1GB GP5-RM1J ■ ■ SDRAM-DIMM (100MHz) 512MBx2 Additional Memory 512MB GP5-RM51J ■ ■ SDRAM-DIMM (100MHz) 256MBx2 Additional Memory 256MB GP5-RM25J ■ ■ SDRAM-DIMM (100MHz) 128MBx2 Additional Memory Board GP5-RB201 ■ ■ Additional memory board for mounting more than 16 DIMMs Additional Memory 1GB GP5-RM1G GP5BRM1G [CTO option] ■ ■ ■ EDO-DIMM(Buffered;50ns)256MBx4 Additional Memory 512MB GP5-RM51G GP5BRM51G [CTO option] ■ ■ ■ EDO-DIMM(Buffered;50ns)128MBx4 Additional Memory 256MB GP5-RM25G GP5BRM25G [CTO option] ■ ■ ■ EDO-DIMM(Buffered;50ns)64MBx4 Additional Memory 128MB GP5-RM12G GP5BRM12G [CTO option] ■ ■ ■ EDO-DIMM(Buffered;50ns)32MBx4 Standart Memory Conversion Kit-1GB GP5BRU1GB [CTO option] ■ ■ ■ Standard Memory conversion 256MB to 1GB Standart Memory Conversion Kit-512MB GP5BRU51B [CTO option] GP5-RM2K GP5BRM2K [CTO option] ■ ■ ■ Standard Memory conversion 256MB to 512MB GP5T2A81A CPU Field Upgrade Kit-56 GP5T2AV1A GP5-FG20A GP5T2AY1A CPU Field Upgrade Kit-61 GP5T2A51A GP5-FG206 GP5BFG206 [CTO option] GP5C880(R) CPU Field Upgrade Kit-53 GP5C881(R) GP5-FG201 GP5BFG201 [CTO option] GP5C883(R) CPU Field Upgrade Kit GP5C885(R) GP5-FG202 GP5BFG202 [CTO option] GP5T3A61A(R) CPU Field Upgrade Kit GP5G880L(R) GP5-FG203 GP5BFG203 [CTO option] GP5G881L(R) CPU Field Upgrade Kit GP5G883L(R) GP5-FG202T GP5G885L(R) CPU Field Upgrade Kit GP5T4A61A(R) ■ GP5T6A11A(R) GP5-FG203T GP5T6A21A(R) CPU Field Upgrade Kit Product ID GP5T6A31A(R) (Overseas inc.Korea) Product GP5T9A22R MS600 MS400 GP5T9A32R HS900 Remarks Pentiumlll Xeon(550MHz)/32KB+2MBcachex1,Placed on motherboard Includes one CPU, For HS900 ■ Pentiumlll Xeon(550MHz)/32KB+1MBcachex1,Placed on motherboard Includes one CPU, For HS900 ■ Pentiumlll Xeon(550MHz)/32KB+2MBcachex1,Placed on motherboard Includes one CPU and dedicated power supply module (VRM) ■ Pentiumlll Xeon(550MHz)/32KB+1MBcachex1,Placed on motherboard Includes one CPU and a dedicated power supply module (VRM) ■ Pentiumlll Xeon(550MHz)/32KB+512KBcachex1,Placed on motherboard Includes one CPU and a dedicated power supply module (VRM) ■ ■ ■ Pentiumlll(733MHz)/32KB+256KB x1, for MS400/ES300 Cannot be used with other frequency and L2cache processor ■ ■ Pentiumlll(750MHz)/32KB+256KB x1, for G800i/C800i Cannot be used with other frequency and L2cache processor ■ ■ Pentiumlll(700MHz)/32KB+256KB x1, for G800i/C800i Cannot be used with other frequency and L2cache processor ■ ■ Pentiumlll(600EMHz)/32KB+256KB x1, for G800i/C800i Cannot be used with other frequency and L2cache processor ■ Pentiumlll(550EMHz)/32KB+256KB x1, for G800i/C800i Cannot be used with other frequency and L2cache processor ■ ■ SDRAM-DIMM 1GBx2 (Registered 100MHz) Additional Memory 1GB GP5-RM1K GP5BRM1K [CTO option] ■ ■ SDRAM-DIMM 512MBx2 (Registered 100MHz) Additional Memory 512MB GP5-RM51K GP5BRM51K [CTO option] ■ ■ SDRAM-DIMM 256MBx2 (Registered 100MHz) Additional Memory 256MB GP5-RM25K GP5BRM51K [CTO option] ■ ■ SDRAM-DIMM 128MBx2 (Registered 100MHz) Additional Memory 128MB GP5-RM12K GP5BRM12K [CTO option] ■ ■ SDRAM-DIMM 64MBx2 (Registered 100MHz) Standard Memory Conversion Kit-2GB GP5BRU2GB [CTO option] ■ ■ Standard Memory conversion 256MB to 2GB Standard Memory Conversion Kit-1GB GP5BRU1GD [CTO option] ■ ■ Standard Memory conversion 256MB to 1GB Standard Memory Conversion Kit-512MB GP5BRU51G [CTO option] ■ ■ Standard Memory conversion 256MB to 512MB Additional Memory 512MB GP5-RM51F ■ ■ ■ ■ Additional Memory 256MB GP5-RM25F ■ ■ ■ ■ ■ ■ ■ ■ SDRAM-DIMM 256MBx1 (Registered 100MHz) Additional Memory 128MB GP5-RM12F ■ ■ ■ ■ ■ ■ ■ ■ SDRAM-DIMM 128MBx1 (Registered 100MHz) Additional Memory 64MB GP5-RM64F ■ ■ ■ ■ ■ ■ ■ ■ SDRAM-DIMM 64MBx1 (Registered 100MHz) Additional Memory 256MB GP5-RM25H GP5BRM25H [CTO option] ■ ■ ■ ■ Unbuffered SDRAM-DIMM 256MBx1 Additional Memory 128MB GP5-RM12H GP5BRM12H [CTO option] ■ ■ ■ ■ Unbuffered SDRAM-DIMM 128MBx1 Additional Memory 2GB SDRAM-DIMM 512MBx1 (Registered 100MHz) 32 teamserver Hardware GP5T2A81A GP5T2AV1A GP5T2AY1A GP5T2A51A ES200 GP5C880(R) GP5C881(R) GP5C883(R) C800i GP5C885(R) GP5T3A61A(R) ES300 GP5G880L(R) GP5G881L(R) GP5G883L(R) G800i GP5G885L(R) GP5T4A61A(R) GP5T6A11A(R) GP5T6A21A(R) (Overseas inc.Korea) MS600 MS400 GP5T6A31A(R) Product ID GP5T9A22R Product GP5T9A32R HS900 Remarks Additional Memory 64MB GP5-RM64H GP5BRM64H [CTO option] ■ ■ ■ ■ Unbuffered SDRAM-DIMM 64MBx1 Standard Memory Conversion Kit-256MB GP5BRU25D [CTO option] ■ ■ ■ ■ Standard Memory conversion 128MB to 256MB Hard Disk Drive-36GB GP5-HDH61T ■ ■ 1.6"height/36.4GB/Ultra2wide SCSI/10000rpm/SCA2 80pin/Hotplug/SMART Hard Disk Drive-18GB GP5-HDH85T ■ ■ 1"height/18.2GB/Ultra2wide SCSI/10000rpm/SCA2 80pin/Hotplug/SMART Hard Disk Drive-9GB GP5-HDH98T ■ ■ 1"height/9.1GB/Ultra2wide SCSI/10000rpm/SCA2 80pin/Hotplug/SMART Hard Disk Drive-36GB GP5-HDH62 GP5BHDH62 [CTO option] ■ ■ ■ ■ Hard Disk Drive-18GB GP5-HDH87 GP5BHDH87 [CTO option] ■ ■ ■ ■ ■ 1"height/18.2GB/Ultra160/Ultra2 Wide SCSI/10000rpm/SCA2 80pin/ Hotplug/SMART/For MS600, MS400, Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A) Hard Disk Drive-9GB GP5-HDH9A GP5BHDH9A [CTO option] ■ ■ ■ ■ ■ 1"height/9.1GB/Ultra160/Ultra2 Wide SCSI/10000rpm/SCA2 80pin/ Hotplug/SMART/For MS600, MS400, Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A) Hard Disk Drive-18GB GP5-HDH84 GP5BHDH84 [CTO option] ■ ■ ■ 1"heught/18.2GB/Ultra2wide SCSI/7200rpm/SCA2 80pin/Hotplug/SMART/ For MS600,Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A) Hard Disk Drive-9GB GP5-HDH97 GP5BHDH97 [CTO option] ■ ■ ■ 1"height/9.1GB/Ultra2wide SCSI/7200rpm/SCA2 80pin/Hotplug/SMART/For MS600, Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A) Hard Disk Drive-18GB GP5-HDH86 GP5BHDH86 [CTO option] ■ ■ 1"height/18.2GB/Ultra2wide SCSI/7200rpm/SCA2 80pin/Hotplug/SMART/For MS400, ES300 Hard Disk Drive-9GB GP5-HDH99 GP5BHDH99 [CTO option] ■ ■ 1"heught/9.1GB/Ultra2wide SCSI/7200rpm/SCA2 80pin/Hotplug/SMART/For MS400, ES300 Hard Disk Drive-18GB GP5-HDH83 ■ ■ ■ ■ ■ ■ ■ ■ 1"height/18.2GB/Ultra2wide SCSI/7200rpm/SCA2 80pin/Hotplug/SMART/For G800i/C800i Hard Disk Drive-9GB GP5-HDH96 ■ ■ ■ ■ ■ ■ ■ ■ 1"heught/9.1GB/Ultra2wide SCSI/7200rpm/SCA2 80pin/Hotplug/SMART/For G800i/C800i Hard Disk Drive-18GB GP5-HD8G1 GP5BHD8G1 [CTO option] ■ ■ ■ ■ ■ ■ ■ ■ 1"height/18.2GB/Ultra2 Wide SCSI/7200rpm/68pin/Non Hotplug/SMART/For GP5-HD9G3 GP5BHD9G3 [CTO option] ■ ■ ■ ■ ■ ■ ■ ■ 1"height/9.1GB/Ultra2 Wide SCSI/7200rpm/68pin/Non Hotplug/SMART/For Hard Disk Drive-9GB 1.6"height/36.4GB/Ultra160/Ultra2 Wide SCSI/10000rpm/SCA2 80pin/ Hotplug/SMART/For MS600,MS400, Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A)* Cannot be mounted in Drive Cage Conversion Kit (GP5BBU1) ES200 (Mounted in HDD Bay)/C800i(C800i is NOT available for CTO) ES200 (Mounted in HDD Bay)/C800i(C800i is NOT available for CTO) GP5-HD8G1B GP5BHD8G1B [CTO option] ■ ■ ■ ■ 1"height/18.2GB/Ultra2 Wide SCSI/7200rpm/68pin/Non Hotplug/SMART/For GP5-HD9G3B GP5BHD9G3B [CTO option] ■ ■ ■ ■ 1"height/9.1GB/Ultra2 Wide SCSI/7200rpm/68pin/Non Hotplug/SMART/For Hard Disk Drive-13GB GP5-HD3E1 GP5BHD3E1 [CTO option] ■ ■ ■ ■ EIDE,5400rpm, 13GB, for ES200 Drive Cage Conversion Kit GP5BBU1 Storage System GP5UR1DC4 Hard Disk Cabinet GP5MS622A DAT unit (DDS-4) GP5-DT401 GP5BDT401 [CTO option] Hard Disk Drive-18GB Hard Disk Drive-9GB ES200 (Mounted in 5"Bay) ES200 (Mounted in 5"Bay) ■ ■ ■ ■ Standard Drive Cage conversion 1ch 1"/1.6"HDDx8 to 2ch 1"HDDx12*An additional PSU is required to mount(Details, Please refer to page 3) ■ ■ R R R R R R R R R R R R R Hard Disk Node LVD/SE (Ultra2 Wide/Ultra Wide)for Rack (4U) 8 Hot plug HDD Bays (up to 291.2GB: 36.4GBx8)/Ultra2 Wide/Ultra Wide SCSI/Redundant&Hotplug FAN(Std.)/PSU(A GP5UR1PU1is standard equipment, up to two) <Required Components> 1. GP5-127/GP5B127-GP5MU823A/GP5S-833/GP5S-834 (HS900/MS600/MS400/ES300) 2. GP5-144(146)/GP5B144(146)-GP5S-832/GP5S-835/GP5S-836 (HS900/MS600/ MS400/ES300) <Available HDD> GP5-HDH62/GP5-HDH87/GP5-HDH9A/GP5-HDH84/GP5-HDH97 P P P P P P P P P P P P P P P P P ■ ■ ■ ■ ■ ■ ■ Hard Disk Node LVD/SE (Ultra2 Wide/Ultra Wide)for Pedestal 8 Hot plug HDD Bays (up to 291.2GB: 36.4GBx8)/Ultra2 Wide/Ultra Wide SCSI/Redundant&Hotplug FAN(Std.)/PSU(A GP5UR1PU1is standard equipment, up to two) <Required Components> 1. GP5-127/GP5B127-GP5MU823A(MS600/MS400/ES300/ES200) 2. GP5-144(146)/GP5B144(146)-GP5S-832(MS600/MS400/ES300/ES200) <Available HDD> GP5-HDH62/GP5-HDH87/GP5-HDH9A/GP5-HDH84/GP5-HDH97 ■ ■ ■ ■ Internal DAT unit (DDS-4:20GB-40GB)/SCSI Card (GP5-127/GP5B127) is required(Exclude HS900) Cable is included. Please refer to Page 4.5 for mounting backup devices 33 teamserver Hardware DAT unit (DDS-3) GP5UDT301 GP5USL501 GP5UDL201 GP5-DL351 Internal DLT unit (DLT4000: 20GB-40GB) Two 5" bays are occupied to mount Please refer to Page 4.5 for mounting backup devices ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Internal DLT unit(DLT7000: 35-70GB) Two 5"bays are required and occupied GP5BDL351 [CTO option] Tape unit (MLR-3) GP5-ML301 Please refer to Page 4.5 for mounting backup devices ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Internal MLR unit (MLR-3: 20-40GB) SCSI Card (GP5-127/GP5B127)is required GP5BML301 [CTO option] Backup Cabinet GP5UR1BC1 GP5T2A81A Please refer to Page 4.5 for mounting backup devices ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ GP5BDL201 [CTO option] DLT unit GP5T2AV1A Please refer to Page 4.5 for mounting backup devices ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Internal SLR unit (SLR-5: 4-8GB) GP5BSL501 [CTO option] DLT unit Remarks ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Internal DAT unit (DDS-3:12-24GB) GP5BDT301 [CTO option] Tape unit (SLR5) GP5T2AY1A GP5T2A51A ES200 GP5C880(R) GP5C881(R) GP5C883(R) C800i GP5C885(R) GP5T3A61A(R) ES300 GP5G880L(R) GP5G881L(R) GP5G883L(R) G800i GP5G885L(R) GP5T4A61A(R) GP5T6A11A(R) GP5T6A21A(R) (Overseas inc.Korea) MS600 MS400 GP5T6A31A(R) Product ID GP5T9A22R Product GP5T9A32R HS900 Please refer to Page 4.5 for mounting backup devices ■ ■ 5" bay node for HS900 (3U) Up to four Tape units can be mounted, GP5UDL351(two bays are occupied),GP5-ML301,GP5-DT401, GP5UDT301,GP5USL501,GP5UDL201 are available/Power management (RCI)/Redundant PSU (Opt.) Redundant Power Supply Unit GP5UPU131 Redundant Power Supply Unit GP5UPU151 ■ ■ ■ ■ ■* ■* Redundant PSU (450W), For G800i ■ Redundant PSU (305W), For ES300 GP5BUPU151 [CTO option] Redundant Power Supply Unit GP5UPU161 * For Backup Cabinet (GP5UR1BC1) ■ ■ ■ ■ Redundant PSU (350W), For MS600/MS400 GP5BUPU161 [CTO option] Redundant Power Supply Unit GP5UR1PU1 Rackmount Pattern GP5RMP 40U Rack GP5-R1RC4 An additional PSU is required if Drive Cage Conversion Kit (GP5BBU1) is used in MS400. ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Redundant PSU for GP5UR1DC4/GP5MS622A (350W) R R R R R R R R R R R R R R R Rackmount pattern instruction ■ ■ R R R R R R R R R R R R R 19'' 40U Locker , Front door,rear door,side panel,earthquake proof board ,blank panel is attached. Size(WxDxH)mm:600x900x2000 <Number of units required for installation> ES300:4U/MS400,MS600:7U,HS900:7U/C800i:6U, G800i:7U GP5UR1DC4: 4U Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard) /Component shelf: 5U CRT/KB switch: Mounted at side of CRT (occupies same U as CRT) 40U Rack&Rack Coupling Kit GP5-R1RC5 ■ ■ R R R R R R R R R R R R R 24U Rack GP5-R2RC1 ■ ■ R R R R R R R R R R R R R 19''40U Locker + connection metal fittings Front door,rear door,concatenation frame,blank panel is attached. 19'' 24U Locker , Front door,rear door,side panel,earthquake proof board, blank panel is attached. Size(WxDxH)mm:600x900x1200 <Number of units required for installation> ES300:4U/MS400,MS600:7U,HS900:7U/C800i:6U, G800i:7U GP5UR1DC4: 4U Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard)/Component shelf: 5U CRT/KB switch: Mounted at side of CRT (occupies same U as CRT) 24U Rack&Rack Coupling Kit GP5-R2RC2 ■ ■ R R R R R R R R R R R R R Component Shelf GP5-R1TB4 Keyboard/Monitor Shelf Kit GP5-R1TB5 Keyboard/Monitor Enhanced Switch GP5-SB101 ■ ■ R R R R R R R R R R R R R ■ ■ R R R R R R R R R R R R R ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Keyboard/Monitor Extension Cables GP5-411 Enhanced Keyboard GP5-R1KB2 SCSI Card GP5-123 19''24U Locker + connection metal fittings Front door,rear door,concatenation frame,blank panel is attached. Shelf to fit peripheral device into 40U Rack, Table size:400(W)x500(D) Used to store display unit (CRT), a keyboard (KB), and a mouse on a rack. Switch enables sharing of a set of CRT,keyboard,and mouse by two or more servers (up to four servers). ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ R R R R R R R R R R R R R ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ CRT/KB cable , CRT cablex1,KB/Mouse cablex1 is attached 87Key keyboard for Rackmountable type Ultrawide (HVD:High Voltage Differential)1ch//SMART HDD is not supported/ Up to 40MB/s of syncronous transfer support/For connection with Disk Array devices -68-pin connector for external SCSI device (Ultra Wide)x1 -68-pin connector for internal SCSI device (Ultra Wide )x1 -50-pin connector for internal SCSI device (Narrow)x1 * SCSI cable is required. SCSI Card GP5-125 ■ ■ ■ ■ Ultra Wide(SE)/1ch/SMART HDD/Transfer speed: up to 40MB/s -68-pin connector for external SCSI device (Ultra Wide)x1 -68-pin connector for internal SCSI device (Ultra Wide SE)x1 -50-pin connector for internal SCSI device (Narrow)x1 (Either external Wide or internal Wide connector can be used in teamserver) *SCSI cable is required SCSI Card GP5-126 ■ ■ ■ ■ Ultra2wide(LVD)/1ch/SMART HDD/Transfer speed: up to 80MB/s GP5B126 [CTO option] -68-pin connector for external SCSI device (Ultra2 Wide)x1 -68-pin connector for internal SCSI device (Ultra2 Wide)x1 -68-pin connector for internal SCSI device (Ultra Wide SE)x1 -50-pin connector for internal SCSI device (Narrow)x1 (Internal Ultra2 Wide and Narrow SCSI can be used in teamserver) *SCSI cable is required 34 teamserver Hardware SCSI Card GP5-127 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ GP5T2A81A GP5T2AV1A GP5T2AY1A GP5T2A51A ES200 GP5C880(R) GP5C881(R) GP5C883(R) C800i GP5C885(R) GP5T3A61A(R) ES300 GP5G880L(R) GP5G881L(R) GP5G883L(R) G800i GP5G885L(R) GP5T4A61A(R) GP5T6A11A(R) GP5T6A21A(R) (Overseas inc.Korea) MS600 MS400 GP5T6A31A(R) Product ID GP5T9A22R Product GP5T9A32R HS900 Remarks ■ ■ ■ ■ Ultra2wide(LVD)/1ch/SMART HDD/Up to 80MB/s of syncronous transfer GP5B127 [CTO option] -68-pin connector for external device (Ultra2 Wide)x1 -68/50-pin connector for internal device (Ultra2 Wide)x1 (Either external or internal connector can be used) SCSI Card ■ ■ ■ GP5-128 Ultra160SCSI/1ch/SMART HDD/Up to 160MB/s of synchronous transfer GP5B128 [CTO option] -68-pin connector for external SCSI device (Ultra160)x1 -68-pin connector for internal SCSI device (Ultra160)x1 -68-pin connector for internal SCSI device (Ultra2 Wide)x1 -50-pin connector for internal SCSI device (Narrow)x1 (Only internal Ultra160 connector can be used in MS600) <Use> For connection internal Ultra160 HDD in MS600 RAID Card ■ ■ ■ ■ GP5U141 ■ ■ ■ ■ RAID card, Ultra Wide SCSI(SE)/2ch/16MB cache/RAID level 0,1,5,6 are supported For internal/external array configuration *SCSI cable(for array configuration use) is required * GP5U141 can be used with GP5U142 in G800i. RAID Card ■ ■ ■ ■ GP5U142 Raid card, Ultra Wide SCSI, SE, x2ch, 4MB cache, RAID level 0,1,5 are supported For internal array configuration *SCSI cable(for array configuration use) is required RAID Card ■ GP5-143 ■ ■ ■ ■ ■ ■ ■ ■ ■ Ultra2 wide(LVD)/1ch/8MB cache/RAID level 0,1,5,6 are supported/For GP5B143 [CTO option] internal array configuration/One GP5-143/GP5B143 can be used in one server*SCSI cable(for array configuration use) is required RAID Card GP5-144 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Ultra2wide (LVD)/3ch/32MB cache/Battery Backup/RAID level 0,1,5,6 are GP5B144 [CTO option] supported For internal/external array configuration *SCSI cable(for array configuration use) is required RAID Card GP5-146 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Ultra2wide (LVD)/2ch/16MB cache/Battery Backup/RAID level 0,1,5,6 are GP5B146 [CTO option] supported For internal/external array configuration *SCSI cable(for array configuration use) is required SCSI Cable GP5S-832 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SCSI Cable GP5S-833 SCSI Cable GP5S-834 SCSI Cable GP5S-835 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SCSI Cable GP5S-836 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SCSI Cable GP5-840 ■ ■ ■ ■ For connection GP5-144/GP5B144 or GP5-146/GP5B146 to GP5UR1DC4/GP5MS622A (3m) For connection GP5-127/GP5B127 to GP5UR1DC4 (5m), Only for Rackmount For connection GP5-127/GP5B127 to GP5UR1DC4(10m), Only for Rackmount For connection GP5-144/GP5B144 or GP5-146/GP5B146 to GP5UR1DC4(5m), Only for Rackmount For connection GP5-144/GP5B144 or GP5-146/GP5B146 to GP5UR1DC4(10m), Only for Rackmount ■ ■ ■ ■ Internal narrow SCSI cable(68pin-50pin) for 5'' Bay of ES200/Connect with GP5B840 [CTO option] SCSI Cable GP5-127/GP5B127 ■ ■ ■ ■ Internal narrow SCSI cable(50pin-50pin) for 5'' Bay of ES200/Connect with GP5-841 GP5B841 [CTO option] SCSI Cable GP5-126/GP5B126 ■ GP5-842 Internal narrow SCSI cable(68pin-50pin) for 5'' Bay of MS400[In case of 2ch GP5B842 [CTO option] Drive Cage(Drive Cage Conversion Kit:GP5BBU1)is used]/Connect with GP5-127/GP5B127 SCSI Cable ■ ■ ■ ■ Internal Wide SCSI cable(68pin-68pin) for ES200/Connect GP5- GP5-843 GP5B843 [CTO option] SCSI Cable GP5MU823A SCSI Cable GP5MU829A SCSI Cable GP5U831 SCSI Cable GP5U832 SCSI Cable GP5U833 SCSI Cable GP5U834 Fibre Channel Cable GP5-311 Fibre Channel Cable GP5-312 Fibre Channel Cable GP5-313 LAN Card (1000Base-SX) GP5-183 126/GP5B126/GP5-143/GP5B143 with Hard Disk Drive ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SCSI-3(68pin)-SCSI-4(68pin), For connecting GP5-127/GP5B127to GP5MS622A,GP5UR1DC4 (3.0m) ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SCSI-3(68pin)-SCSI-4(68pin), For connecting GP5U141to GP5MS622A,GP5UR1DC4 (2.0m) ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Connenction internal backup devices in C800i ■ ■ ■ ■ ■ ■ ■ GP5B183 [CTO option] LAN Card GP5-185 GP5USM103 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SCSI Cable half68pin-Full50pin (1.0m)/For connect external SCSI device SCSI Cable half68pin-half50pin (1.0m)/For connect external SCSI device SCSI Cable half50pin-full50pin (1.0m)/For connect external SCSI device Fibre Channel Card (3m) : For FC Card (GP5-FC101)/Giga LAN Card (GP5-183) Fibre Channel Card (5m) : For FC Card (GP5-FC101)/Giga LAN Card (GP5-183) Fibre Channel Card (15m) : For FC Card (GP5-FC101)/Giga LAN Card (GP5-183) 1000BASE-SX/PCI64bit/driver is included Fibre Channel cable is required : GP5-311/2m, GP5-312/5m, GP5-313/15m ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 100BASE-TX/10BASE-T/PCI64bitTwisted pair cable (category 5:100BASE- GP5B185 [CTO option] Server Monitor Module ■ ■ ■ ■ ■ ■ ■ TX/category 3:10BASE-T) is required ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Server Monitor Module has its own CPU,LAN,and power supply (AC adapter: GP5BUSM103 [CTO option] option-procured locally)/External Interface:10BASE-T RJ45/RS232C D-sub 9pin/AC adapter:16V(DC) * Modem-only operation is impossible. 35 Specifications are subject to change without notice. For the latest detailed information, contact your local representative. All brand names and product names are trademarks and registered trademarks of their respective holders. C1999 Fujitsu Limited. All rights reserved. Printed in Japan. Eighth Edition February 2000 FUJITSU LIMITED Business Development & Marketing Division Marketing Group Marunouchi Center Building 6-1, Marunouchi 1-chome, Chiyoda-ku, Tokyo 100-8211, Japan Phone: +81-3-3215-5255 Fax: +81-3-3215-5259 URL http://www.fujitsu.co.jp/index-e.html BK0065-8NS