SUSI Adapters, Inc. Retrofit Relay Adapter (SWL) Cost-effective solution for upgrading old relays Easy installation Retrofits into existing switchboard relay case Relay Adapter with VAMP 55 Relay Adapters with MiCOM P111 Description These Retrofit Relay Adapter (SWL series) allows the user to install a Schneider Electric protection relay into an existing switchboard panel. The installation can be done in minutes without de-energizing the circuit or re-wiring anything since the most cases have CT shorting mechanisms built in. Easy installation translates into lower labor costs, which makes the relay upgrade feasible for many applications. With this solution, you can cost-effectively offer your customer the newest relay technology without shutting down their circuit or being concerned about mis-wiring or handing asbestos wiring. Once the relay/adapter has been installed, your user will have the benefit of a new electronic relay. ADVANTAGES Retrofits directly into ABB, GE, and Basler relay cases Cost-effective solution for upgrading old relays Easy installation: Minutes not hours No re-wiring or shutting off power is needed Matching operating characteristics of old relays Increased communication options for remote access Enhanced protection capabilities Local indication, real-time measurements, event recording, disturbance recording and self monitoring Relay setting files can be downloaded, archived and reused for other upgrades Multiple level passwords give proper rights for secure maintenance of the relay 600-1800-00-E 9560 Red Bird Lane · Johns Creek, GA 30022 · Phone: 770-448-6810 · Fax: 770-448-7260 · sales@SUSIadapters.com · www.SUSIadapters.com SUSI Adapters, Inc. Make Relay Type Description Schneider Relay SUSI Adapter ABB CO Time Overcurrent VAMP50S ABB MCO Time Overcurrent VAMP50S ABB MMCO Time Overcurrent VAMP50S Make Relay Description Type Schneider Relay SUSI Adapter GE IAC Time Overcurrent (EM) MiCOM P111 GE IFC Time Overcurrent (EM) MiCOM P111 ABB SC Instantaneous Overcurrent MiCOM P111 GE SFC Time Overcurrent (EM) MiCOM P111 ABB CM Current Unbalance MiCOM P111 GE DIAC Time Overcurrent (EM) MiCOM P111 ABB POQ Current Unbalance MiCOM P111 GE DIFC Time Overcurrent (EM) MiCOM P111 ABB SOQ Current Unbalance MiCOM P111 GE DSFC Time Overcurrent (EM) MiCOM P111 ABB CV Over/Under Voltage VAMP55 GE BFC Instantaneous Overcurrent MiCOM P111 ABB KP Over/Under Voltage VAMP55 GE CHC Instantaneous Overcurrent MiCOM P111 ABB KV Over/Under Voltage VAMP55 GE PJC Instantaneous Overcurrent MiCOM P111 ABB SV Over/Under Voltage VAMP55 GE HFC Instantaneous Overcurrent MiCOM P111 ABB KF Frequency VAMP55 GE IJC Current Unbalance MiCOM P111 ABB MDF Frequency VAMP55 GE IAV Over/Under Voltage VAMP55 ABB RC Reclosing MiCOM P111 GE IFV Over/Under Voltage VAMP55 ABB IMPRS Three Phase Overcurrent MiCOM P111 GE CFV Over/Under Voltage VAMP55 BASLER BE1-50 Overcurrent MiCOM P111 GE IRC Over/Under Voltage VAMP55 BASLER BE1-50/51 Overcurrent MiCOM P111 GE NGV Over/Under Voltage VAMP55 BASLER BE1-51 Overcurrent MiCOM P111 GE PJV Over/Under Voltage VAMP55 BASLER BE1-27 Undervoltage VAMP55 GE NBV Voltage Unbalance VAMP55 BASLER BE1-27/59 Undervoltage VAMP55 GE IJF Frequency VAMP55 BASLER BE1-59 Overvoltage VAMP55 GE SFF Frequency VAMP55 BASLER BE1-59N Overvoltage VAMP55 GE NLR Reclosing MiCOM P111 BASLER BE1-27/59 Overvoltage VAMP55 GE NSR Reclosing MiCOM P111 BASLER BE1-47N Voltage Unbalance VAMP55 GE SLR Reclosing MiCOM P111 BASLER BE1-81O/U Frequency VAMP55 BASLER BE1-79A Reclosing MiCOM P111 BASLER BE1-79M Reclosing MiCOM P111 SWL11IAC1C SWL11SLR1C *To use original cover replace “C” with “N”. The relay will be in the recessed position and no cover will be shipped. SWL55WKF1 SWL11IMP1 600-1800-00-E 9560 Red Bird Lane · Johns Creek, GA 30022 · Phone: 770-448-6810 · Fax: 770-448-7260 · sales@SUSIadapters.com · www.SUSIadapters.com