FLUID CONTROL RESEARCH INSTITUTE (Under Ministry of Heavy Industries & Public Enterprises, Govt. of India) Kanjikode West, Palakkad – 678 623, Kerala Email: training@fcriindia.com Website: www.fcriindia.com FCRI, a state of the art flow and fluid engineering facility, first of its kind in South East Asia is dedicated to Research & Development in Fluid Flow Measurement & Control Techniques. About 100 sponsored Projects for various reputed organisations have been successfully completed by the Institute. The Institute provides facilities towards technological developments to the flow product industries and serves as a National Certifying Authority and Quality / reliability evaluation facility. The Institute also provides facility for calibration of mechanical, thermal, electrical parameters, noise, vibration etc. apart from testing and calibration, the Institute conducts National and International training programmes in the field of flow control, measurement & Instrumentation, Calibration and related areas. Laboratory Fluid flow NABL C026/T027 Water Flow Air Flow At Ambient conditions Maximum Flow Rate (m3/hr) 15000 Maximum Line Size 2000mm 10000 400mm Closed loop Air Test Facility (20 Bar) *Calibration Loop *Gravimetric Loop Velocity Oil Flow 400 50 650 150mm 50mm 200mm Compressed Natural Gas 4500 Kg/hr 40 mm Calibration & Measurement Capability 0.0025 mg to 1 g 0.001 mg/g to 100 mg/kg Parameters Mechanical Calibration Metrological, Pressure, Noise, Vibration etc. NABL C 056 MASS-Standards Weights MASS-Weighing Balance & Mass Comparator VOLUME -Specific Gravity Bottle, Pipettes, Burettes Measuring Flasks DENSITY Hydrometers 0.6 g/cc – 1.98 g/cc ±0.01% ±0.0005 g/cc 1mPas to 60000 mPas/cSt ±0.7% rdg ±1% rdg Acoustic Pressure 94 dB @ 1 Khz 114 dB @ 1 Khz 124 dB @ 250 Hz 30 to 130 dB 31.5 Hz to 16 KHz 0.3 dB Sound Power 1.2 dB ±0.3% ±0.1% 0-100m3/hr: ±0.05% 100-600m3/hr:±0.075% ±0.1% Parameters PRESSURE-Dead weight tester Barometric Pressure Gauge Pressure: Pressure Transducers, Pressure Calibrators, Pressure Transmitters, Pressure Switches, Pressure Gauges. Uncertainty in Volume (% reading) 0.20m3 : ± 0.05% 0-0.5 m3: ±0.1% 2 m3: ±0.1% 0-9 m3: ±0.05% Range 6 to 60 bar 100 to 1200 bar >(600 to 1300) mbar 1 bar to 60 bar & 100 bar to 1200 bar Calibration & Measurement Capability 0.021% of rdg 0.035% of rdg 0.02% rdg 0.02% rdg 0.035% rdg Absolute Pressure – (Pneumatic): Pressure Calibrators, Pressure Transmitters, Gauges, Switches Vacuum / Negative Pressure Gauges, Transducers, Transmitters, Calibrators, Switches 30 mbar abs to 2000 mbar abs 0.25 bar abs to 20 bar abs -100 mbar to 980 mbar 0.02% rdg Low Pressure Gauges & Differential (Pneumatic): Transducers, Calibrators, Transmitters, Gauges, Switches Gauges/ Differential Pressure – (Pneumatic): Transducers, Calibrators, Transmitters, Gauges, Switches 0.2 mbar to 3.2 mbar 3.2 tp 9.5 mbar 10 to 160 mbar 100 mbar to 2000 mbar 14 bar to 140 bar 1.4% rdg Gauge / Differential Pressure Transducer (Pneumatic) Barometric Pressure 2 bar to 20 bar 0.015% rdg >(600 to 1300) mbar 0.5 – 100 mm 0.02% rdg Speed (Contact) 100 to 10000 rpm 1.6rpm Speed (Non-contact) 60 -10000 rpm 10000 -50000 rpm 50000 -10000 rpm 10 to 100 m/s2 (1 to 10g) 2Hz-15 KHz 1.0 rpm 2.0 rpm 3.5 rpm 2.4% (5 Hz to 5 KHz) 1.3% to 2.5% Vibration Sensor Sensitivity Check DC Voltage Source Measure 100-160Hz 1.30% LENGTH-Slip Gauges(steel) ±100µV to ±1000 V ±0.1mV to ±1000V 0.66% to 0.001% 0.64% to 0.001% DC Current Source Measure AC Voltage Source Measure 1mV to 1000V 10mV to 1000V 0.4% -o 0.014% 0.028% - 0.014% AC Current Source Measure ±100µA to ±1000A ±100µA to ±20A 1mA to 1000A 100µA to 20A Resistance Source Measure Time 1µΩ – 10G Ω 0.1Ω – 1G Ω 1 Sec – 5400 sec Frequency Source 1 Hz to 1Ghz Frequency Measure 1 Hz to 1 Ghz Temperature -70 ºC to +1200 ºC 8.56% to 0.415% 0.062% to 0.2% 1.53 µSec to 5.4mSec ±0.022ºC to 1.3ºC Fixed Point Cells -38.8344ºC to 961.78ºC *Temperature & Humidity Chamber 5ºC to 70ºC 10% to 95% RH *IP Tests Dust IP 5X& IP6X Water IP X3 to IP X8 Vibration Sensor Electro Technical Calibration NABL C 0254 1mg and upto 500kg Various ranges from 0-2 g to 60600 Kg and upto 0-20000kg 0.05 ml – 5000 ml VISCOSITY-Liquids & Viscometers Acceleration Thermal Calibration NABL C 0255 Range Uncertainty in Flow Rate (% reading) 0-1800 m3/hr: ±0.05% 1800-4500 m3/hr: ±0.15% 4500-15000 m3/hr: ±0.5% 0.05-0.25 m3/hr: ±0.2% 0-25-40 m3/hr: ±0.1% 40-10000 m3/hr: ±0.25% 0.026% rdg 0.10% rdg 0.55% rdg 0.05% rdg 0.04% rdg 0.06% rdg 0.05μm to 0.16 μm 0.014% to 0.48% 0.015% - 0.05% 0.02% to 0.51% 0.07% to 0.11% 0.3% to 0.00012% 10.3µHz to 1.54 Hz 7.1mºC to 24mºC National and International trade depends on acceptable system of measurement standards for efficient operation. Recognizing critical role of metrology, the International Standards Organisation (ISO) has given it a due important place in the International Quality Standards – ISO 9000, 14000 & 18000 series by incorporating specific clauses on Calibration and Traceability. The course covers specification of laboratory reference equipments, testing and calibration techniques including documentation, traceability, uncertainty evaluation as required by ISO 17025/NABL 141 guidelines for accreditation of laboratories in different areas like Mechanical, thermal, Electro-technical etc. Basics of Measurement and Calibration Dimensional metrology – Precision Measurement / calibration Techniques Mass Calibration demonstration Pressure Metrology and Calibration of Pressure measuring instruments demonstration Thermometry and Calibration demonstration Transducers, transmitters and calibration techniques Laboratory accreditation as per NABL Norms Traceability and inter-comparison campaigns Quality Standards and relevance of calibration Assessment of uncertainty of measurements for laboratory environs Venue Course Timings : : FCRI, Kanjikode West, Palakkad 9.30 a.m. to 5.30 p.m. Personnel with 2-3 years experience in Metrological or inspection sectors and quality groups from Engineering Industries, process control & instrumentation and other related areas can participate. Fees For Indians working in India : Rs. 13,230/- + Service Tax@ 12.36% Rs. 1,635/= Total Rs. 14,865/- per participant For Those Working Abroad : US $ 778 + Service Tax @12.36% US $ 96 + Charge US $ 20 = Total US $ 894 per participant. Control Valves/Actuators Water Meters Butterfly Valves & Actuators Venting devices/air valves Safety Relief Valves Gas Turbine Meters Gas Regulators Diaphragm Gas meters Cv, FL, Seat leakage test, Fugitive emission, cryogenic testing, torque All test as per IS6784, IS779,IS2373, IS04064 POD tests as per AWWA C504 & C540 API 2000 ASME PTC 25 OIMLR137-1 Model Approval BS EN 334 BS EN 1359 Model Approval Life Cycle Tests & Cavitation Tests for valves Agency Category National Accreditation Board for Testing and Calibration Laboratories (NABL) Netherlands Measurement Institute (NMI) Department of Science & Technology Department of Weights & Measures (Ministry of Civil Supplies) Chief Controller of Explosives, Nagpur Bureau of Indian Standards Institution of Fire Engineers, New Delhi Central Pollution Control Board Nuclear Power Corporation Ministry of External Affairs (ITEC) & Ministry of Finance, Dept. of Economic Affairs (Colombo Plan) GCAS Quality Certification Pvt. Ltd Calibration/Testing of Flow Products, Mechanical Measurements Thermal Calibration, Electro Technical Calibration CLATF (20 Bar, 400 m3/h) of FCRI complies with the criteria for Calibration Laboratories as per ISO/IEC 17025 Recognized R&D Institute Model Approval tests on flowmeter for custody transfer of oil/gas as per OIML Standard Testing of Safety Relief Valves Testing of Water Meters, Anemometers etc. Hydraulic Qualification tests on fire fighting equipments Certification of Petrol, Kerosene & Diesel Generators for type approval Seismic Studies for Power plant Equipments Training programmes for Foreign Nationals on Flow Measurement and Instrumentation for Oil Gas & Water utilities/industries ISO 9001:2008 Certification in Calibration & testing of fluid flow component, calibration of mechanical, electro technical, thermal instruments, flow calibration & measurements at site, project consultancy & implementation, professional training. Registration for the training program can be confirmed by sending the details: Name, Designation, Organisation, Postal Address Email/Phone/Fax/Post to the address given below. The course fee is to be remitted in advance through crossed Demand Draft favouring “Fluid Control Research Institute”, payable at Palakkad. The registration must be completed on or before 04rth August 2014. For further information & Registration, please contact: Director, Fluid Control Research Institute Kanjikode West, Palakkad-678623, Kerala, India Telephone: 0491-2566206, 2566120, Fax: 0491-2566326 Email: training@fcriindia.com Website: www.fcriindia.com