This document provides guidance for applicants on how to gain certification on Radio Apparatus when using Timco
Engineering Inc. as the Certification Body. This guide is only applicable for gaining certifications on Radio
Apparatus intended for the Canadian market.
The actual requirements specified by Industry Canada for certification are contained within document CB-03
(Requirements for the Certification of Radio Apparatus to Industry Canada’s Standards and Specifications). To aid
applicants with the certification process Timco has created this guidance document based on CB-03 although it
should be noted that CB-03 is the base requirement and will always take precedence.
Any comments or suggestions regarding this document would be welcomed. Please forward your comments to:
Quality Assurance Manager
Timco Engineering, Inc.
849 NW State Road 45
PO Box 370
Newberry, FL 32669 USA
Alternatively you may send e-mail to tei@timcoengr.com.
Page 2 of 15
D:\106735552.doc
____________________________________________________________________________
Contents
Introduction..................................................................................................................................................2
1.
Company Profile.............................................................................................................................4
2.
Eligible Products.............................................................................................................................4
3.
Test Facility Requirements............................................................................................................4
4.
Certification Fees............................................................................................................................5
4.1
Fee Schedule................................................................................................................. ............................5
4.2
Methods of Payment......................................................................................................................... ........5
5.
Application Procedures..................................................................................................................5
5.1
Documentation requirements................................................................................................... .................5
5.2
Guidance on completing your application................................................................................................6
5.3
Format of application..........................................................................................................................…12
6.
The Certification Process.............................................................................................................12
6.1
Preliminary Evaluation....................................................................................................... ....................12
6.2
Service Level........................................................................................................................................ ..12
6.3
Confidentiality.............................................................................................................. ..........................13
7.
Certification Number Format......................................................................................................13
8.
Modification of certified equipment............................................................................................14
9.
Certification retention and audits...............................................................................................14
9.1
Continuing compliance...........................................................................................................................14
9.2
Transfer of certificates..................................................................................................... ........................14
10.
Withdrawal of certification..........................................................................................................14
11.
Appeals...........................................................................................................................................15
12.
References......................................................................................................................................15
Page 3 of 15
D:\106735552.doc
____________________________________________________________________________
1.
Company Profile
Timco Engineering, Inc. is privately owned and incorporated in the State of Florida. Timco offers EMC testing and
certification services to customers worldwide.
Our knowledgeable engineering staff has over 65 years of combined experience in EMC testing. Company
representatives in China and Korea help us to serve our international clients in an efficient manner.
Timco’s accreditations include ISO/IEC 17025 and ISO/IEC 17065.
2.
Eligible Products
Industry Canada separated Radio Apparatus into two categories depending on whether certification is required or
not. All Category I apparatus must be certified.
Radio Communications Equipment is subject to the applicable requirements of the Radio Standards Specifications
(RSS) or Broadcasting Equipment Technical Standards (BETS) standards on the Category I equipment Standards
List. Note that Radio Communications Equipment imported only for demonstration or trial does not need to be
certified. However, it does require an experimental radio license. Refer to Industry Canada publication RIC-66
(Radio Communication Information Circular 66) for details of Industry Canada offices. The office closest to the
demonstration or trial site should be contacted.
The Category I standards list is published on the Spectrum Management and Telecommunications section of the
Industry Canada website. http://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/h_sf01342.html
The list is subject to change without notice.
3.
Test Facility Requirements
The certification and testing departments are operated separately within Timco Engineering, Inc. This is to ensure
that all applications with test data provided from any acceptable test facility are processed equally.
Test laboratories are considered to be competent to perform the required measurements if:
1)
The laboratory testing the EUT meets our requirements. If you are accredited to ISO/IEC 17025 there
are no further requirements. If you are not accredited to 17025 then you must prove to us that you are
capable of testing & preparing the report for the EUT in question.
2)
For measurements where an OATS is required, the laboratory must have their OATS listed with
Industry Canada.
Page 4 of 15
D:\106735552.doc
____________________________________________________________________________
4.
Certification Fees
4.1
Fee Schedule
Contact us for a Price for Certification.
4.2
Methods of payment
The following methods of payment are acceptable



Credit Card (Visa, Mastercard, American Express)
Check or Money Order (made payable to Timco Engineering, Inc.)
Wire Transfer to the following account:
*Contact us for current wire transfer information
Payment is to be in United States Dollars drawn on a US Bank.
5.
Application procedure
5.1
Documentation requirements
The following documents shall be submitted with the certification application depending on the Type of
Certification Service(s) listed at the bottom of the table. Please review the details below the table for guidance.
Type of
Service
REQUIRED EXHIBIT
Application Cover Letter: A letter with explanation of the type of Certification Service
requested and brief description of the radio equipment.
Timco’s Certification Application Form (Appendix I & II Form)
RSP-100 Annex A: A completed and signed copy required.
RSP-100 Annex B: A completed and signed copy required.
RSS-102 Annex A/B or C: A completed and signed copy of Annex A and B or C of RSS-102
─ Radio Frequency Exposure Compliance of Radiocommunication Apparatus (All Frequency
Bands)
Canadian Representative Letter: The applicant-Canadian Representative agreement signed by
the Canadian Representative.
Agent/Authorization Letter: If the applicant has authorized another entity for legal
representation on their behalf, this agreement shall be submitted.
Certificate: If a new or revised certification certificate has been issued by a CB for the
product(s), a copy of the issued certificate shall be submitted.
RSP-100 Annex D: A completed and signed copy required for only modular certification.
Radio Test Report: A detailed test report meeting the technical requirements of the applicable
Radio Standards Specification (RSS) and/or BETS.
RSS-102 Compliance: SAR Test Report or RF Evaluation for the product.
Photos: Internal and External photos of the product versions in the application.
Manual: Product manual with applicable user notifications and operational description.
Schematics and Block Diagrams
Product Label: Actual label & label location photo(s) or illustration of the product label.
Confidentiality Request: A letter stating the confidential documents.
Family Certification Information: A letter/diagrams/photos explaining/showing the
similarities and differences between the versions of the product. May include
All
All
All
All
All
All
All*
All*
All*
All*
All*
All*
All*
All*
2, 3
Page 5 of 15
D:\106735552.doc
____________________________________________________________________________
schematics/diagrams/photos if necessary.
Modification Information: A signed letter explaining/showing the changes to the existing
version of the product. May include schematics/diagrams/photos if necessary.
Original Applicant Authorization: A letter signed by original applicant authorizing new
Applicant to certify the product for Multiple Listing or Transfer of TAC.
3, 4
5, 6
All – The requirement applicable for all 1,2,3,4,5,6 types of Certification Services listed below.
* For all types of applications, if this document is identical to the document with the original filing,
the document can be om
omitted.
1 – New Single Product Certification;
2 – New Family Product Certification;
3 – Add New Product to Existing Family/(C1PC, C2PC);
4 – Modifications/(C3PC, C4PC);
5 – Multiple Listing of Certification;
6 – Full/Partial Transfer of Certification
The application forms detailed above may be downloaded from our website www.timcoengr.com or can be
requested from us directly. Please contact us at tei@timcoengr.com or 1-800-472-2424 should you require any
further guidance on the application requirements.
5.2
Guidance on completing your application form
To assist you in ensuring that your application is complete the following guidelines can be used:

Cover letter
This should detail the contents of your application with specific attention being made to previous certification
numbers if applicable and the product and applicant details.
Appendix I - Certification Application Form
Section 1: Applicant information
Complete all contact information for the Applicant. It should be noted that the applicant maintains all
responsibility for the application and the certification agreement. Timco may, if necessary contact the applicant
directly. You must already have a Company Number assigned by Industry Canada. If you do not then you
must contact Certification Engineering Bureau at Industry Canada directly.
Section 2: Canadian Representative information
What do we mean by Canadian representative? The applicant must provide in writing the identity of a
representative in Canada who is capable of responding to inquiries and who can provide post-certification audit
samples at no charge to Industry Canada or to Timco. Complete all contact information for the Canadian
representative.
Section 3: Manufacturer
Please list the Manufacturer contact information.
Section 4: Customer
Page 6 of 15
D:\106735552.doc
____________________________________________________________________________
Please list the main point of contact information for the application submitted.
Section 5: Certification Number
The Certification Number is made up of the applicant’s company number and the unique product number of
their choosing. Details are provided in section 7 of this Guide.
Section 6: Hardware Version Id Number (HVIN)
The Hardware Version Identification Number (HVIN) identifies hardware specs of a product version. HVIN
replaces the IC Model Number in the legacy E-filing System. HVIN is required for all products for certification
applications.
Please list all model numbers for the device
Section 7: product Marketing Name (PMN)
The Product Marketing Name (PMN) is the name or model number under which the product will be
marketed/offered for sale in Canada. The PMN must be provided before the product is listed in REL and made
available on the Canadian Market.
Section 8: Firmware Version Identification Number (FVIN)
The Firmware Version Identification Number (FVIN) identifies the firmware version utilized by the product
which controls/affects the RF characteristics of the product.
Section 9: Host Marketing Name (HMN)
The Host Marketing Name (HMN) is the name or model number of a final product which contains a certified
radio module.
If the device meet the Modular Approval or Limited Modular Approval Requirements please mark this here.
Please note RSP-100 Annex D will be required for submission.
Section 10: Description of Product as it is Marketed:
Please list the description of the device that is to be placed on the certificate.
Section 11: Specification Standard
Please list the Standard that the device was tested to. Include the issue number of the Standard as well.
Section 12: Type of Equipment
The Type of Equipment description comes from a list provided by IC, see link. You may also refer to the list in
Appendix 1 of this Guide and select the appropriate type of equipment from the list and type it into the space
provided. This information will be used when the certification is uploaded to the REL. Type of Radio
Equipment
Section 13: Equipment Information
Please mark whether or not this device is a Transmitter or Scanner Receiver.
Section 14: Type of Service (Per RSP-100)
This section specifies which certification services are being requested.
Page 7 of 15
D:\106735552.doc
____________________________________________________________________________
New Certification (Single) - A new single certification may be granted to products (final product or module)
provided that the applicant has never been granted certification for the assigned HVIN and IC certification
number in the application.
o The PMN may be identical to HVIN and vice versa.
o The FVIN must be provided if applicable otherwise please enter “N/A” as FVIN.
o The HMN is only required for modular certifications when module compliance was assessed in a
host.
o Documents must be submitted as per Annex C.
New Family Certification - A new family certification may be granted to products (final products or modules)
provided that the applicant has never been granted certification for the assigned HVIN(s) and IC certification
number in the application.
o At least one field (PMN, HVIN or FVIN) must be unique to identify different version(s) of the
product for new family certification.
o Family certification information document(s) must list the PMN, HVIN and FVIN of all the
product versions within the application to explain in detail the hardware and/or software
similarities/differences (RF characteristics, circuitry design, function capabilities etc.) between all
the versions.
o If FVIN is the only differentiation between product versions (PMN and HVIN remain identical)
within the family certification application then FVIN must be provided.
o The HMN is only required for modular certifications when module compliance was assessed in a
host.
o Documents must be submitted as per Annex C.
Existing Family/ Modification (Add Model, C1PC, C2PC) - If family certification is requested and at
least one model in the family has been certified.
o
o
o
o
o
PMN, HVIN or FVIN may be identical or different from the existing certified version(s) of the
product. Additionally, if the application contains two or more product versions, the product
versions must have at least one unique field (PMN, HVIN or FVIN) to identify different
version(s).
The HMN is only required for modular certifications when module compliance was assessed in a
host.
Any permitted modifications (hardware or software) to the original certified product which may
affect the RF must be supported by a test report with full or partial testing.
The modifications to the existing certified product shall comply with the requirements of Class I/II
Permissive Changes.
The documents shall be submitted as per Annex C and shall include:
 A detailed description of the firmware/hardware changes/differences (RF characteristics,
circuitry design, and functional capabilities) between different versions of the product.
 The changes/differences may be detailed with photographs, block diagrams, schematics
and product literature.
 A brief statement as to how the modifications to the product meet the Class I/II
modification requirements and/or family certification requirements.
Modifications (C3PC, C4PC) Product Modifications (C3PC) Application
o PMN and HVIN must remain identical to the existing certified product while a new and unique
FVIN must be provided.
o A detailed information in the “Modification Information” document(s) shall include and not
limited to:
 Detailed description of the RF characteristics and/or functional changes to the certified
product due the firmware change.
Page 8 of 15
D:\106735552.doc
____________________________________________________________________________


A brief statement as to how the modifications meet the Class III modification
requirements.
Documents must be submitted as per Annex C.
Product Modifications (C4PC) Application
o The SAR/RF exposure testing/evaluation in the new host shall be provided.
o When the module integration affects the RF emissions characteristics, a test report with full or
partial testing and updated RF emissions information shall be submitted.
o HMN must be provided.
o The documents shall be submitted as per Annex C and the provided information shall include
details regarding the module integration including statements regarding changes to module’s
original reported RF emissions characteristics and/or SAR/RF exposure evaluation/testing.
Multiple Listing (Add Applicant) - Multiple listing of a certified model is required when a manufacturer
or distributor wishes to list under its name and unique model number, certified equipment of an original
equipment manufacturer (OEM). A model of equipment may be multiple-listed to other manufacturers or
distributors based upon the approval granted to the original applicant and certificate holder.
o The existing certificate holder or another entity/company (new applicant) may request a new IC
certification number based on existing certification of a product.
o The new application shall include a unique IC certification number for which certification has
never been granted to the applicant.
o The selected HVIN, PMN and/or FVIN in the new application may be identical or different from
the existing certification provided the applicant has never obtained certification for the selected
HVIN, PMN and FVIN combination in the application.
o The product version(s) in the new application must be identical (C1PC permitted) to the existing
certification.
o The “Application Cover Letter” from the new applicant shall include:
 Product details (IC Certification Number, PMN, HVIN, FVIN when applicable) from the
existing certification and new application.
 Declaration that the new product version is identical to the certified product.
 Declaration that the documents on-file with IC from the original certification, remain
unchanged and continue to be valid.
o The “Original Applicant Authorization” letter from the existing certificate holder shall include:
 Product identification details (IC Certification Number, PMN, HVIN, FVIN when
applicable) from the existing certification and new application.
 Authorization for the existing certified product to be listed under the new
applicant/company.
 Authorization for IC to utilized documents on-file with IC from the existing certification.
 Documents must be submitted as per Annex C.
Full Transfer of Certifications (Company Takeover): This application service is applicable when
one company takes over another company.
o
o
o
o
The new company/applicant must assume all of the responsibilities associated with all existing
certifications from the existing certificate holder and shall provide a signed statement with this
fact.
The new applicant shall submit a copy of a signed letter from the current certificate holder,
authorizing the IC Certification Bureau to transfer the certificate ownership from the current
certificate holder to the to the new applicant and change the certificate file information to reflect
the new certificate holder’s information.
The HVIN and IC certification number shall remain unchanged.
Documents must be submitted as per Annex C.
Page 9 of 15
D:\106735552.doc
____________________________________________________________________________
Partial Transfer of Certifications (A Product Line Takeover): This application service is applicable
when one company takes over one or more product line(s) but not all of the product lines from another
company.
o For the product line(s) being transferred, the new company/applicant must assume all of the
responsibilities associated with the existing certifications from the existing certificate holder and
shall provide a signed statement with this fact.
o If all the certified products associated with the particular Company Number (123A-1234, 123A is
CN) are subject to transfer, then the new applicant/company has the option of retaining the
existing IC certification number(s) and HVIN(s). Alternatively, going forward, the new
applicant/company may assign new IC certification number(s) to all the transferred product lines.
o The new applicant shall submit a copy of a signed letter from the existing certificate holder,
authorizing IC to transfer the certificate ownership to the new applicant and change the certificate
file information to reflect the new certificate holder’s information.
o Documents must be submitted as per Annex C.
Section 15: Is this product subject to TEL listing per Declaration of Conformity Procedures DC-01 (CS-03)?
Terminal equipment that is also a radio apparatus requires certification under the Radiocommunication Act.
Notification to the Department of the certification to the applicable Radio Standards Specifications and the
registration of the terminal equipment must be performed at the same time.
Section 16: Agreement
The agreement must be signed by the applicant or authorized agent. The signatory will hold all responsibility
for the applicant even of an agent is used to make the application. All terms and conditions are accepted by
signing this form.
Appendix II – Test Report Cover Page/Performance Test Data
Section 17: Product Information
Copy and paste from Appendix I form
Section 18: Test Site Company Number
Please list the IC Test Site Registration Number. Link to search Test Site Registration Number is provided.
Section 19: SAR Lab Company Number
Please list the IC SAR Lab Registration Number. Link to search Test Site Registration Number is provided
Section 20: Equipment Specifications- Each Section must be completed unless otherwise stated.
RSS# & Issue#: list as follows- RSS-210; 8
Frequency Range: must list frequency in MHz and list Min and Max
RF Power: Units must be listed in- Watts.
Or
Field Strength: Units must be listed in- dBuV @ distance of 3m, 10m, 30m, or 300m
Measured Bandwidth: Units must be listed in- kHz
Page 10 of 15
D:\106735552.doc
____________________________________________________________________________
Method: Units must be listed in one of the following- 6dB, 20dB, 26dB, 99%, or other
Necessary Bandwidth: Units must be listed in- kHz
Emission Classification: Example- F1D, G1D, D1D, etc.
Transmitter Spurious: Units must be listed in one of the following- uV, uW, dBc, dBm, dBw, or dBuV
Receiver Spurious: Units must be listed in one of the following- uV, uW, dBc, dBm, dBw, or dBuV
If item 13 is marked as Scanning Receiver, please be sure to complete this information for the receiver
portion.
Antenna Type & Gain: Must be listed on the IC Certificate.
Section 21: Declaration
The declaration must be signed by the Test Lab.
RSP-100, Annex D – Modular Approval Attestation
Modular Checklist/ Information
Product Information and Checklist must be completed and signed for equipment that fall under Modular
Approval.
RSS-102, Annex A – RF Technical Brief Cover Sheet
RF Exposure: SAR and RF (MPE) Evaluation – RSS-102
All fields must be completed with the requested information or the following codes: N/A, N/P, or N/V
RSS-102, Annex B – Declaration of RF Exposure Compliance
Must be signed if Annex A- (a), (b), (c), or (d) has been completed. The declaration must be signed by the Test
Lab/ SAR Lab.
RSS-102, Annex C – Declaration of RF Exposure Compliance for Exemption from Routine
Evaluation Limits
Must be signed if Annex A & B are Not Applicable. The declaration must be signed by the Test Lab/ SAR Lab.
Page 11 of 15
D:\106735552.doc
____________________________________________________________________________
5.3
Format of application
The application should be supplied in electronic format and uploaded via our FTP site. To access our upload site,
you must have a registered user name and password. If you are an existing customer who already has a username
and password there is no further action necessary. If you do not have a user name and password you will be
required to register. To do so log on to our web site at www.timcoengr.com and select “Register” in the top right
corner of the page. Complete all fields and submit the registration. Your registration will be processed and your
user name and password is active immediately.
Acceptable file formats are Adobe PDF and Microsoft Word! File sizes should be less than 6.0 Mega Bytes.
6.
The Certification Process
6.1
Technical Brief RSP 100
On receipt of your application, the application will be logged in and given a unique job number. The
application/technical brief s will be reviewed.
If information is missing then a Problem on Hold Letter will be started before the test report is given to the reviewer.
After review the Problem on Hold (POH) will be emailed to you.
Only on receipt of all documentation and payment will the certification process be commenced. At this stage the
application fee becomes non-refundable.
6.2
Service Level
Timco Engineering, Inc. strives to provide the highest level of customer service possible to ensure that our
customers get prompt certification whilst still ensuring that our integrity is maintained. In view of this we have set
ourselves service levels with respect to our certification activities.
As our customer you should expect form us the following levels of service:
A Project Letter Email will be sent to you upon receipt of the application.
Notification of certification decision within 5 additional working days.
This may be to request additional information prior to a certification being granted or to inform you that the
application was successful.
You will be notified on completion of the preliminary evaluation if there are any delays foreseen due to workload.
We will keep you informed to ensure that your expectations can be met.
After certification is granted by Timco, product information will be provided to Industry Canada for inclusion on the
Radio Equipment List (REL). You must not make your product available to the Canadian marketplace until the
apparatus is listed on the REL. The time frame for including the apparatus on the REL is based on Industry
Canada’s workload and is outside of Timco’s control.
During the technical evaluation it may be necessary for more documentation or test data to be provided. Again, you
will be contacted in writing to notify you of the additional information required. Please note that applications that
have been inactive for more than 30 days will be closed. A new application must be made should this situation
occur. A new application fee will also be required.
Page 12 of 15
D:\106735552.doc
____________________________________________________________________________
6.3
Confidentiality
The certification scheme being used involves close contact with Industry Canada in their capacity as regulator.
During the course of our operations for this scheme it may be necessary to supply, or make available for inspection,
records relating to your product as evidence of compliance to applicable standards.
Confidentiality for all other third parties will be maintained unless written permission from the certificate holder is
received.
7.
Certification Number Format
All certified equipment must be labeled with a unique certification number. The certification number should be
preceded by the terms “IC:” then the applicant’s Company Number (CN) and Unique Product Number (UPN).
The CN is assigned by Industry Canada and the UPN by the Certificate holder.
How do I obtain a Company Number (CN)?
Company Numbers must be obtained by electronically filing a request through IC’s website, prior to applying for
equipment certification. Provide the full company name, mailing address, telephone number, fax number, contact
name and email address to Timco. Timco will then submit the request for IC Company Number electronically to IC.
Please request a company number before sending your submission. A CN can only be obtained via the certification
and engineering bureau.
The certification number shall appear as follows:
IC: XXXXXX – YYYYYYYY
Where
The letters IC have no other meaning or purpose than to identify that Industry Canada Certification Number
XXXXXX – YYYYYYYY is the certification number
XXXXXX is the company number (CN) made up of at most 6 alpha-numeric characters
(A – Z, 0 – 9) assigned by Industry Canada
YYYYYYYY is the Unique Product Number (UPN) made up of at most 11 alpha-numeric characters
(A – Z, 0 – 9) assigned by the applicant
The alpha-numeric characters are limited to capital letters (A – Z) and digits (0 – 9). Other characters, such as #, / or
– shall not be used. An example of a certification label is as follows:
IC: 21A – A3
Where 21A is the CN and A3 is the UPN
Page 13 of 15
D:\106735552.doc
____________________________________________________________________________
8.
Modification of certified equipment
Certain Modifications made to previously certified apparatus may affect the validity of the certification. It is the
responsibility of the certificate holder to ensure that a product continues to comply. We therefore require that the
certificate holder inform Timco Engineering, Inc. or Industry Canada to determine whether modifications require recertification.
9.
Certification retention and audits
9.1
Continuing compliance
It is a requirement that the certificate holder ensure that all production units of certified equipment continue to
comply with all requirements relating to the original certification. Receipt by Timco Engineering, Inc. of a signed
application form signifies acceptance of these conditions.
The adherence of subsequent production units to the technical quality and characteristics under which certification
was originally issued is implicit. To this end, periodic testing shall be carried out by certificate holders to ensure
continuing compliance with the technical standards.
ISO / IEC 17065 and the Industry Canada certifications requirements detailed in CB-01, CB-02 and CB-03 require
that a certification body performs surveillance activities to ensure continuing compliance of certified products.
Timco Engineering, Inc. employs a system of performing random audits to monitor continuing compliance. This
random audit procedure will mean that a production sample of a certified product may be requested form the
certificate holder and be subjected to some additional testing. This sample should be provided at no cost to Timco
Engineering, Inc. Refer to section 4 for detail costs associated with the audit program.
Note: In accordance with Industry Canada document CB-03 section 10.3, Industry Canada may request, from
certificate holders, random radio apparatus samples at the certificate holders expense for post-certificate audit testing
or as a result of radio interference complaints. This request is independent from any that Timco may make to uphold
a certificate.
If any non-compliances are noted then corrective action will be required from the certificate holder.
9.2
Transfer of certificates
Industry Canada requires that all certified products have a current certificate from a recognized CB. If for any
reason you have certificates from a CB which has ceased to operate or has had recognition withdrawn then you must
have the certification transferred to another Certification Body.
Timco Engineering, Inc. offers a transfer service to aid you with this requirement. However, a full application
package must be submitted. Please contact the certification department prior to submitting such an application to
further discuss the requirements.
10.
Withdrawal of certification
Withdrawal of certification can occur if non-compliance with the certification requirements has been identified and
suitable corrective action has not been implemented.
On withdrawal of certification by Timco Engineering, Inc. Industry Canada, the applicant, and the customer will be
notified that the certification is being withdrawn and that the equipment will be removed from the Radio Equipment
Page 14 of 15
D:\106735552.doc
____________________________________________________________________________
List (REL). All offending equipment must be removed from service and the equipment must NOT be made
available for sale in Canada. The Applicant and the Customer will be notified by email.
11.
Appeals
Timco Engineering, Inc. maintains and operates procedures to effectively handle appeals from its customers. All
appeals should be made in writing to the:
Quality Manager
Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669 USA
Industry Canada is the final arbiter on disputes relating to technical decisions with respect to Canadian regulations.
You may contact Industry Canada at:
Certification and Engineering Bureau
Industry Canada
PO Box 11490 Station H
3701 Carling Avenue
Building 94
Ottawa, Ontario K2H 8S2
Canada
Email: certification.bureau@ic.gc.ca
12.
References
The following documents have been used in creating this Guide for Applicants:
RSP-100 Issue 11, Draft
Radio Equipment Certification Procedure
CB-01 Issue 4, October 2011
Requirements for Certification Bodies
CB-02 Issue 6, October 2011
Recognition Criteria, and Administrative and Operational Requirements
Applicable to Certification Bodies for the Certification of Radio Apparatus to
Industry Canada’s Standards and Specifications
CB-03 Issue 2, June 2007
Requirements for the Certification of Radio Apparatus to Industry Canada’s
Standards and Specifications
Page 15 of 15
D:\106735552.doc