ELTRY251 Chap 11 Quiz 05 Practice Please Print Name: KEY Electrical Integration Describe the following Item 1 Description PV Electrical Installation should be done by and Inspected by 1. Licensed Technician or Contractor 2. Authority Having Jurisdiction (AHJ) 2 Majority of Rules and Regulations are Govern by 3 What is A PV Power Source? 4 What is a PV A circuit which connect a group of modules together and to the Source Circuit? common connection point of the DC system 5 What is a PV Circuit which connect PV Power Source to the rest of the Output Circuit? system NEC An array or collection of arrays that generates DC power 6 What is the maximum PV system Voltage? Array’s Open Circuit Voltage at Lowest temperature 7 What is the maximum Residential PV system Voltage? 600 VDC C:\PCC\Eltry251\Quizzes\ Page 1 of 5 ELTRY251 Chap 11 Quiz 05 Practice Please Print Name: 8 9 10 What is the Maximum PV system Current? # 12 AWG and #10 AWG, Which one has larger Diameter? # 12 AWG and #10 AWG, Which one has larger Ampacity? KEY Electrical Integration 125% of Array’s Short Circuit Current 125% is for variation in Irradiance # 10 AWG # 10 AWG 11 What is NEC Recommended Voltage Drop? 12 What should be the color of White or Gray Grounded Conductor? 13 What should be the color of Bare, Green, green with Yellow Strips Grounding Conductor? 14 What should be Any Color other than, White, Gray, and Green the color of DC Red or Black Ungrounded AC Black, Red, Blue Conductor? 15 All connection except Module connections should be within a 3% Junction Box C:\PCC\Eltry251\Quizzes\ Page 2 of 5 ELTRY251 Chap 11 Quiz 05 Practice Please Print Name: KEY Electrical Integration 16 What are the characteristics of the module connectors? 1. 2. 3. 4. 5. 17 What are NEC requirements for DC Plugs and Receptacles? 1. Must be rated and marked for DC with min 15 A rating 2. Must have a grounding terminal 3. Must be different than all other plugs in the location 18 When Conduits When Conductors are accessible and voltage is over 30 V are required? 19 What is the function of Over-current Protection Devices? 20 What are causes of Overcurrent 21 22 23 Can same type of Fuse be used for both AC and DC Circuits? Can Automotive fuses be used in PV DC Circuits? What is current rating of the Over-current protection devices? Must be polarized Must have Locking mechanism must protect against accidental contact with person Must use a tool to disconnect and have marking Grounding conductor must connect 1st and break last Prevents conductors and devices form excessive temperature due to high current 1. Over Load 2. Ground Fault 3. Short Circuit No No 125% of Maximum Current This is in addition to 125% conductor rating C:\PCC\Eltry251\Quizzes\ Page 3 of 5 ELTRY251 Chap 11 Quiz 05 Practice Please Print Name: KEY Electrical Integration 24 What is Interrupting Current? Maximum current that an over-current protection device can handle without arcing or shorting 25 What is the function of Disconnect? To isolate conductors and equipment from the source 26 27 28 Describe the Conductors connections in the DC Disconnect. Describe the Conductors connections in the AC Disconnect. What type of circuit breaker is used for inverter/utility connection? 1. Only Positive (+) conductor (RED) will be connected to Line side of Disconnect. 2. Negative (-) conductor (WHITE) and Grounding Conductor (GREEN) are neither switched nor connected to each other 1. Conductors (2) from Inverter will be connected to the Load side of disconnect 2. Conductors (2) to the Service panel will be connected to the Line side of disconnect Back-fed 29 What are the functions of grounding? 1. Provides a safe pass for fault currents and lightning 2. Provides protection foe people and equipment 30 Which PV Systems require grounding? Any system with a maximum voltage of 50 V or more. This is the adjusted voltage for low temperature. 31 What is Grounding Electrode? What is its Function? 1. A conductive rod or bare wire buried under ground 2. Provides a low resistance to ground C:\PCC\Eltry251\Quizzes\ Page 4 of 5 Please Print Name: KEY ELTRY251 Chap 11 Quiz 05 Practice Electrical Integration 32 What is Ground Fault and typically caused by what? 33 What is Ground The automatic opening of the conductors involved with Ground Fault Fault Protection? 34 What are 2 different types of Ground Fault Protections? 35 What are the functions of GFDI and GFCI? 1. Undesirable current flowing through the grounding conductor it could cause significant shock or fire hazard 2. Typically caused by damage to the protective insulation of the current carrying conductor 1. Ground Fault Detection and Interrupter (GFDI) 2. Ground Fault Circuit Interrupter (GFCI) 1. GFDI Protect equipment 2. GFCI Protect people C:\PCC\Eltry251\Quizzes\ Page 5 of 5