PD110 Signal Surge Protection Device PD110 Signal Surge Protection Device Features ·Multi-level protection ·Lower residual voltage ·Good transmitting ability ·Short response time ·Long lifetime Introduction PD110 signal surge protection device has aluminum-alloy housing, with easy installation, wiring and convenient maintenance, the product can be used in rugged environment for a long time. It is used with twisted-pair connection instrument or network data system electronic equipment, in order to prevent induction voltage produced by lightning or industrial noise, overcurrent and other system or equipment damage or breakoff caused by moment surge voltage. The product is generally used for data transmitting wire, monitoring circuitry, equipment circuitry and other audio signal transmitting wire. Specifications Working Type PD110 Transmitting Inserting voltage rate wastage (V) (bit/s) (db) 24 200K ≤0.5 Turnover 8/20us(kA) ≤5 Limited voltage 10/700us(V) ≤40 Interface Protected type core wire Wiring A pair of terminal wire Outline dimension L×W×H(mm) 73×25×35 Environment 1. Operation temperature: -25℃~+70℃; 2. Storage temperature: -40℃~+85℃; 3. Relative humidity: ≤95%; 4. Used in the room or the places where is no rain and snow; Installation Wiring chart 1 st signal wire 1 st signal wire Inputing terminal Pd110signal surge protection device 2nd signal wire Outing terminal equipment 2nd signal wire grounding collection board -1- http: //www.microsensor.cn Add: No.18,Yingda Road Baoji,P.R.China, Tel: +86 917 3600739/3600832 721006 Fax:3609977 PD110 Signal Surge Protection Device Note 1. Please pay attention that the protection device should be series connected between signal channel and protected instrument; 2. Protection device input and output sides are terminals; input “IN” connects with signal channel; output “OUT” connects with protected instrument. Please connect the connector reliably, do not connect conversed. 3. If the protection device bottom is grounding side, please do grounding stably; There is the wiring connector on GND wire screw to connect grounding collection line and signal SPD earth wire. please screw down certainly after grounding,. The grounding wire had better be copper wire (diameter more than 4mm2 ). The distance between grounding wire and collection line should be less than 1m and as shorter and thicker as possible; grounding resistor should be less than 10Ω. -2- http: //www.microsensor.cn Add: No.18,Yingda Road Baoji,P.R.China, Tel: +86 917 3600739/3600832 721006 Fax:3609977