SN110 Shownet Ethernet Nodes

advertisement
Strand Lighting Specification
I.
SHOWNET ETHERNET SIGNAL DISTRIBUTION
A. GENERAL
1. The Strand Lighting ShowNet network shall provide data distribution over a TCP/IP ethernet
Network. Systems using proprietary formats or formats other than TCP/IP shall not be
accepted.
2. Furnish and install complete with all accessories an EIA/TIA 568A, Category 5, Structured
Cabling System (SCS). The SCS system shall serve as a vehicle for transport of lighting
data, video, and console communication signals throughout the building from designated
demarcation points to outlets located at various desk, workstation and other locations as
indicated on the contract drawings and described herein. Application standards supported
should include, but be not limited to, 10Base5, 10BASE-T, and100 Base-T and 52/155
Mbps ATM.
3. Data pairs shall be extended between the station location and it's associated IDF. The cable
shall consist of 4 pair 24 gauge, solid copper conductors, U.L. verified to Category 5
standards. Cables shall be terminated on each of the RJ-45 jacks provided at each outlet.
Voice jacks shall also utilize this cable type.
4. Installing contractors shall provide full test and certification documents on all network wiring.
A wire map, Near End Cross Talk, attenuation, and the installed length shall be recorded for
each category 5 cables. No cable run shall exceed 250 feet.
B. CAPACITIES
1. The Network shall provide DMX routing and patching for up to 18,432 DMX addresses and
DMX data may be output in a variety of output formats to any DMX node in the system. DMX
input, routing and output shall be specifically supported on the system from multiple sources
and locations.
2. The system shall support multiple consoles, computers, file servers, printers with discrete
command lines and control. The ShowNet system may support multiple facilities within a
complex.
3. System configuration shall be via Strand ShowNet Windows software or where applicable
any Web browser and permit simple point and click connection between Consoles and
Nodes, Consoles and Consoles, and Consoles and File Servers. The software shall permit
complete user flexibility allowing the system operator to define DMX data groups, Node
Names and console names for easy identification. Each node shall have a specific user
selectable IP address. Systems that do not support simple Windows operation shall not be
acceptable.
4. Outputs may be created from multiple overlapping sources with up to 3 levels of patch
priority.
5. DMX data streams may consist of any range of 512 numbers from the available system
capacity allowing complex number ranges to be created using “and” and “thru” command
structures.
Page 1
Strand Lighting Specification
6. All configuration data for each Network device shall be held at the device and system
operation shall not require continuous on line operation of the Network configuration
software.
7. ShowNet Interface List
The following interfaces shall be provided on each network:
a.
b.
c.
d.
e.
f.
g.
h.
i.
Remote Handheld Control
Serial Data (Remote Dimmer Supervisor)
Multiple Remote Printers
Serial Data (Spare)
Universal DMX512 Dimmer Mux up to 18,432 outputs (36 standard DMX Universes)
Remote Faders and Switches
MIDI Input
MIDI Through
MIDI Output
C. OPERATIONAL FEATURES
1. The video monitor outputs at any video node shall be able to monitor the video output of any
300 or 500 series console connected to the Ethernet with Networker software. Each Video
node shall have discrete display access to any console and any console display.
2. Each Node shall control up to 1024 DMX addresses, within the confines of an up to a 36
DMX (18,432 DMX addresses) “universe” system. The specific DMX data input or output by
the Node shall be freely configurable by the user. Duplicate outputs of DMX lines (DMX
splitter) and discrete outputs shall be fully supported.
3. Any number of DMX lines may be configured with any length up to 512 addresses as long as
the total does not exceed 18,432. Any range of DMX addresses may be selected for each
feed and may be any set of 512 numbers from the total available on the network. Numbers
may be selected in any order and the use of “and” plus “thru” commands shall be supported
with ShowNet Professional software. Multiple sources may be combined on any node output
and a priority may be assigned to each source. Each DMX output on each node may have its
own label and start address for ease of use.
4. DMX ports shall be configurable for either input or output. Multiple DMX signal routing
patches and multiple facilities shall be specifically supported and limited only by the file
storage capacity of the computer with ShowNet software installed.
5. The Network shall support Parallel, Remote and Tracking Back up operation of 300 and 500
series control consoles.
6. File transmission, synchronization and access to File Servers using Microsoft XP server
software shall be specifically supported.
7. All Network configuration information shall be available as a system printout. Specific
printouts shall be available to assist in the addressing of DMX devices on the network.
Page 2
Strand Lighting Specification
II.
SN110 DMX ETHERNET NODE
A. GENERAL
1. The SN110 Node shall be an intelligent, wall mounting, Ethernet node providing DMX and
Reporter Dimmer data distribution.
2. Connections shall be made between nodes over standard Ethernet distribution systems
using 10BaseT or 100BaseTX wiring or a combination of systems. Each Node shall be
supplied with an integral LCD display for labeling and status monitoring. It shall incorporate
an external low voltage power supply generated by a standard power supply or by an
Ethernet Hub conforming to the IEEE802.3af standard. It shall be designed and
manufactured by a company operating a quality system approved to ISO9001.
B. PHYSICAL
1. The Node electronics shall be supplied with a back box suitable for flush or surface mounting
and finished in powder coat blue. There shall be no visible fasteners.
2. The Node shall be designed for use in Power over Ethernet applications.
3. The Node shall feature a total of 2 XLR connectors on the front panel.
a. There shall 2 DMX512 (512 dimmers per port, selectable In/Out), 5 pin female XLR connectors
standard.
b. It shall be possible to factory configure the connectors to be male or female and 5 pin to meet
project requirements.
4. An LCD display shall be provided to dynamically label each node and receptacle. The display
shall be user configurable using a standard Web Browser or Strand ShowNet software.
C. ELECTRONICS
1. The node processor shall be an industry standard 32-bit microprocessor with integral
10/100BT Ethernet support.
2. Configuration of the Node shall be stored in non volatile memory.
D. OPERATIONAL FEATURES
1. The Node shall be remotely configured via the network system wiring using either Strand
ShowNet software or a standard Web Browser.
2. The Node shall control up to 1024 DMX channels, within the confines of an up to 36 DMX
“universe” system. The specific DMX channels input or output by the Node shall be freely
configurable by the user.
3. Outputs may be created from multiple overlapping sources with up to 3 levels of patch
priority.
4. All ports may be configured as a DMX input or output. Ports may also be configured as an
RS 485 data input onto the network to support dimmer status reporting.
E. ENVIRONMENTAL
1. The ambient operating temperature shall be 0° to 40°C (32° to 104°F).
2. The storage temperature shall be -40° to 70°C (-40° to 158°F).
3. The operating humidity shall be 5% - 95% non-condensing.
Page 3
Strand Lighting Specification
F. STANDARDS COMPLIANCE
1. EMC emissions to EN50081-1, EN55014; EMC immunity to EN50082-1, IEC1000-2-2;
Safety: EN60950, EN60439 Part 1 (also part 12 BS5486); design & build: ISO9000, UL1950.
Ethernet IEEE
2. The Node shall be CE UL & cUL listed.
III. Strand xConnect Designer Remote Software
A. GENERAL
1. The Strand xConnect Designer remote USB drive assembly shall allow users of any
Windows XP or Mac OS/X computer to connect to any Strand Lighting 300 or 500 series
console over a ShowNet Ethernet network.
2. Each drive shall include Strand Designer Remote Software and complete console operators
manuals in both HTML and PDF format.
3. The software shall be supplied on a standard USB memory drive.
B. OPERATIONAL FEATURES
1. The software shall allow a user to connect to any Strand 300 or 500 series console as a
remote user and receive console video display information. Each console display shall
appear in a separate window and up to four windows/screens may be displayed. The
standard display shall be two windows/screens, four screens shall be available only with
consoles equipped for four displays.
2. Users may log in using one of two modes for system access. Monitor mode shall allow a
user to view screens only. The full log in mode shall allow the operator full control access to
the lighting system and support record and playback operation as well as level setting.
3. A simple set up option shall be provided to allow a user to select one of three on screen
buttons for instant access to any control console within a system. Console connections shall
be made by entering the IP address of the desired console, the user number (1-5) and the
desired number of console display windows.
4. Each 300 console shall support one remote user. All 500 series consoles with I build
software shall support up to 4 remote users.
5. The system shall support both wired and wireless Ethernet access allowing the user to
access console displays anywhere within a theatre or studio. A single wireless WiFi access
point shall support multiple users and will support Wireless Handheld remote access
simultaneously.
C. INCLUDED FURNISHINGS
1. USB memory key with system software installed
2. Keyboard short cut template
a. A keyboard short cut template shall be provided to allow users to cross reference 300 or 500 series
console commands and displays to a standard computer keyboard.
3. Operators instruction sheet for Mac OS/X and Windows XP installation and operations.
4. Lanyard and key chain
Page 4
Strand Lighting Specification
IV. Strand Designer Remote Notebook
A. GENERAL
1. The Strand xConnect Designer remote Notebook computer and USB drive assembly shall
allow users to connect to any Strand Lighting 300 or 500 series console over a ShowNet
Ethernet network and receive console video displays.
2. Each system shall include Strand Designer Remote Software and complete console
operators manuals in both HTML and PDF format.
3. The system shall include built in WiFi wireless Ethernet and shall allow the operator to
access the lighting system from any location in the theatre or studio.
B. OPERATIONAL FEATURES
1. The system shall allow a user to connect to any Strand 300 or 500 series console as a
remote user and receive console video display information. Each console display shall
appear in a separate window and up to four windows/screens may be displayed. The
standard display shall be two windows/screens, four screens shall be available only with
consoles equipped for four displays.
2. Users may log in using one of two modes for system access. Monitor mode shall allow a
user to view screens only. The full log in mode shall allow the operator full control access to
the lighting system and support record and playback operation as well as level setting.
3. A simple set up option shall be provided to allow a user to select one of three on screen
buttons for instant access to any control console within a system. Console connections shall
be made by entering the IP address of the desired console, the user number (1-5) and the
desired number of console display windows.
4. Each 300 console shall support one remote user. All 500 series consoles with I build
software shall support up to 4 remote users.
5. The system shall support both wired and wireless Ethernet access allowing the user to
access console displays anywhere within a theatre or studio. A single wireless WiFi access
point shall support multiple users and will support Wireless Handheld remote access
simultaneously.
6. The system Web browser shall allow the operator to access and configure all SN110 nodes
and other browser enabled network devices including hubs and wireless access points.
C. INCLUDED FURNISHINGS
1. One portable notebook computer with Windows XP operating system and USB memory key
with system software installed. System shall include 30GB harddrive, integral WiFi and wired
Ethernet access, 512MB ram and 15 inch XGA display
2. One wireless access point for remote system connectivity
3. Keyboard short cut template
a. A keyboard short cut template shall be provided to allow users to cross reference 300 or 500 series
console commands and displays to a standard computer keyboard.
4. Operators instruction sheet for Mac OS/X and Windows XP installation and operations.
Page 5
Strand Lighting Specification
D. OPTIONS
1. Reporter Pro for Windows XP software shall be an available option to allow users to
remotely configure and monitor dimmer system operation
2. A MAC OS/X notebook computer shall be available as an alternate to the base Windows XP
notebook
V.
Wireless Focus Remote
A. GENERAL
1. The wireless focus remote shall be based on a standard Handheld PDA operating with
Windows Pocket PC software.
2. Each remote shall included integral WiFI 802.11B wireless electronics for communication
with a standard WiFi access point.
B. OPERATIONAL FEATURES
1. Each remote shall be capable of connecting to any Strand 300 or 500 series console or
showcontroller using a simple IP address selection system
2. Each 500 series consoles shall accept inputs from up to 4 wireless remotes and each 300
series console shall accept inputs from up to 2 remotes simultaneously.
3. The remote software shall offer the following facilities
a.
b.
c.
d.
Direct dimmer access for patching and focusing lights
The ability to record cues, groups, submasters, preset focus data, and patch information
Full access to all channel control commands and remote call up of submasters
Playback access to all console playbacks with go stop and go to cue commands
4. The remotes shall include a standard Web browser which shall permit users to remotely
access and configure all SN110 series nodes. The Browser shall also allow users to access
and configure suitably equipped Ethernet Hubs, Switches and Access points for complete
network management.
C. INCLUDED FURNISHINGS
1. Each remote shall be shipped with all standard accessories including:
a.
b.
c.
d.
e.
f.
System set up and configuration disks
Console software disk
Battery Charger and USB cables
Belt holster
System operation Instructions
Smart Digital Card with system restore software
Page 6
Download