List of test equipment for IEC 60950 3rd ed.

advertisement
COMMITTEE OF TESTING LABORATORIES
IEC SYSTEM FOR CONFIRMITY TESTING AND
CERTIFICATION OF ELECTRICAL EQUIPMENT
TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING
IEC 60309-2:1999-04, Edition 4.0 + A1:2005
Plugs, socket-outlets and couplers for industrial purposes Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories
R=Required by Lab
S=May be subcontracted
3PPS=Three Phase Power Supply required
Clause
7.6
8
Measurement/testing
Check of markings
Dimensions
9.1
10.2
11.2.1
11.3.1
11.3.8
Protection against electric shock
Measurement of contact resistance
Test of insertability of conductors
Test of insertability of conductors
Bending test
11.5.1
11.5.2
11.6
11.7.1
Mechanical test
Pull test
Votage drop test
Temperature-cycling test
February 2007
Testing / measuring equipment / material needed
Water, petroleum spirit, piece of close
Gauges according to Fig. 101,102,107,108, 110, 112, 109, 113, 104,
111, 105, 114, dynamometer, caliper
Figure 2: Standard test finger
AC source, measuring instruments
Figure 13: Gauges
Figure 13: Gauges
Figure 19: Test device incl. current source and measuring
instruments
Figure 15: Test device incl. weights and torquemeter
Weights and torquemeter
Heating cabinet, current source, measuring instruments
Heating cabinet, current source, measuring instruments
1/3
Subcontracting
R
R
R
R
R
R
R
R
R
R
R
IEC 60309-2
COMMITTEE OF TESTING LABORATORIES
IEC SYSTEM FOR CONFIRMITY TESTING AND
CERTIFICATION OF ELECTRICAL EQUIPMENT
Clause
11.7.2
13
15.1
15.2
Measurement/testing
Short-time withstand current test
Resistance to ageing
Contact pressure test
Check of withdrawal force
16.101
17.102
18.2
18.5
19.2
19.3
19.4
20
Check of phase inverting means
Check of phase inverting means
Test of degrees of protection
Humidity treatment
Insulation resistance test
Electric strenght test
Check with gauges
Breaking capacity test
21
Normal operation test
22
23.3
Temperature rise test
Cord anchorage test
24.1
24.2
24.3
24.4
24.5
25.1
26.1
27.2
27.3
Cold treatment
Impact test
Mechanical strenght test
Flexing test
Torque test at screwed glands
Torque test at screws
Creepage distances, clearances
Heat treatment
Ball-pressure test
February 2007
Testing / measuring equipment / material needed
Current source, measuring instruments
Heating cabinet
Gauges according to table 110, dynamometer
Test apparatus according to Fig. 115, gauges according to table 111,
dynamometer
Appropriate test apparatus
Appropriate test apparatus
Test equipment according to IEC 60529 and torquemeter
Humidity chamber
Insulation test equipment
High voltage test equipment
Gauges according to Fig. 104, 109, 111, 113, dynamometer
Appropriate test apparatus, power source, adjustable load (resistors
and inductors), measuring instruments
Appropriate test apparatus, power source, adjustable load (resistors
and inductors), measuring instruments
AC source, measuring instruments, temperature measuring device
Torquemeter, test apparatus according to Fig. 6 incl. weights
Apparatus for torque test
Refrigerator
Figure 7: impact test apparatus
Arrangement according to Fig. 8
Apparatus according to Fig. 9
Appropriate test arrangement incl. metal rods
Torquemeter
Caliper, appropriate gauges
Heating cabinet
Heating cabinet, apparatus according to Fig. 10, caliper
2/3
Subcontracting
S
R
R
R
R
R
R
R
R
R
R
S
3PPS
S
3PPS
S
R
R
R
R
R
R
R
R
R
R
IEC 60309-2
COMMITTEE OF TESTING LABORATORIES
IEC SYSTEM FOR CONFIRMITY TESTING AND
CERTIFICATION OF ELECTRICAL EQUIPMENT
Clause
27.4
27.5
28
29
Measurement/testing
Glow-wire test
Tracking test
Corrosion test
Short-circuit current withstand test
Testing / measuring equipment / material needed
Test apparatus according to IEC 60695-2-10
Test apparatus according to IEC 60112
Chemicals, humidity cabinet, heating cabinet
Short-circuit testing arrangement according to Fig. 16, 17, 18 incl.
appropriate measuring devices
Subcontracting
R
R
R
S
3PPS
Note: The presence of equipment alone does not indicate a satisfactory situation. Assessors must evaluate the equipment design, calibration, uncertainty and
documentation to ensure compliance with the directions of the standard. The requirements of ISO Guide 25 regarding validation are applicable, as the tests of this
standard are not standardized tests.