Progetto Trieste 2011, 1st round, Veterinary Drug Residues Proficiency Testing Service by Test Veritas S.r.l. TEST MATERIAL: U1111-1A and U1111-2A (confirmatory) RAL’s IN BOVINE URINE - incurred 2011, 1st round Test material A are two different samples: 1A and 2A - please test both materials! LABORATORY: … ANALYST: ... COMPOUNDS U1111-1A RESULTS CONCENTRATION CORRECTED FOR RECOVERY* (g/l) RECOVERY % DATE: ... SPECIFICATIONS DECISION DETECTION LIMIT ISO CAPABILITY 17025** CC or CC cut-off yes/no (g/l) (g/l) ZERANOL TALERANOL COMPOUNDS U1111-2A RESULTS CONCENTRATION CORRECTED FOR RECOVERY* (g/l) RECOVERY % SPECIFICATIONS DECISION DETECTION LIMIT ISO CAPABILITY CC or 17025** CC cut-off yes/no (g/l) (g/l) ZERANOL TALERANOL Please indicate the concentration in relation to liquid urine sample (not of the powder) Comments: * Please indicate: estimated concentration corrected with recovery if the compound is detected; "< of…" if the compound is not detected; "NS" if the compound is not searched (see example above reported). **Please indicate whether the method used is in the scope of accreditation (choose “yes” if the methods is already accreditated). Example: COMPOUNDS Compound 1 Compound 2 Compound 3 RESULTS SPECIFICATIONS CONCENTRATION CORRECTED FOR RECOVERY* (g/l) RECOVERY % 3.2 NS < 0.5 80 - DECISION LIMIT CC or cut-off (g/l) 1.0 0.5 DETECTION CAPABILITY CC (g/l) ISO 17025** yes/no 1.5 1.0 y n TEST MATERIAL: U1111-1A and U1111-2A (confirmatory) PAGINA 1 di 5 REVISIONE DATA DELLA REVISIONE N. 0 03/01/2011 The data of your analyses will be preserved for 5 years and then will be destroyed. D:\106745372.doc DOCUMENTO AGGIORNATO IL 01/03/11 Progetto Trieste 2011, 1st round, Veterinary Drug Residues Proficiency Testing Service by Test Veritas S.r.l. RAL’s IN BOVINE URINE - incurred 2011, 1st round LABORATORY: … ANALYST: … MARK YOUR CHOICE Analytical methods used by participants Methods GC/MS GC/MS/MS Other (specify) HPLC/MS HPLC/MS/MS UPLC/MS/MS Is the analytical method a routine one? No Yes Source of standards for chromatographyc analysis ZER TAL Sigma, Aldrich, Fluka Riedel-de Haen RIVM Steraloids NARL dr. Ehrenstorfer Other (specify) Sample preparation Amount of test sample for the extraction Sample volume (ml) 5 10 Other (specify) 1.5 2 3 Sample treatment C18 C18 + NH2 Liq-Liq extraction (n-hexan) Liq-Liq extraction (dichloromethane) Liq-Liq extraction (TBME) Liq-Liq extraction (ether) -glucoronidase -gluc-aryl sulfatase Extraction (SPE or other) SPE extraction OASIS® HLB Other (specify) Other extraction pentane „Detectabuse® “ column Other (specify) Digestion Other (specify) TEST MATERIAL: U1111-1A and U1111-2A (confirmatory) RAL’s IN BOVINE URINE - incurred PAGINA 2 di 5 REVISIONE DATA DELLA REVISIONE N. 0 03/01/2011 The data of your analyses will be preserved for 5 years and then will be destroyed. D:\106745372.doc DOCUMENTO AGGIORNATO IL 01/03/11 Progetto Trieste 2011, 1st round, Veterinary Drug Residues Proficiency Testing Service by Test Veritas S.r.l. 2011, 1st round LABORATORY: … C18 C18+ NH2 OASIS® OASIS® HLB Immunoaffinity chromatography Liq-Liq extraction (TBME) Liq-Liq extraction (n-hexane) ANALYST: … Clean up (SPE or other) SPE clean up Nexus + NH2 Strata® - X Envi Chrom P+NH2+SiOH Other (specify) Other clean up Liq-Liq extraction (ether) Liq-Liq extraction (diethyl ether) Other (specify) HPLC methodology and conditions HPLC Isocratic Column phase Other (specify) Column length (cm) 15 Other (specify) Column diameter (mm) 3 Other (specify) Particle size (m) 3.5 5 Other (specify) Cromatographyc column (type) Prodigy® Symmetry® Synergi® Superspher® SupelcosilTM Ultrabase® X-BridgeTM X-terra® YMCTM Zebron® Zorbax® Other (specify) Gradient C18 5 10 2 2.1 1.7 2.5 3 AcquityTM AscentisTM AtlantisTM Beckman Betasil GeminiTM Hypersil® Hypercab® HyPURITY Lichrospher® Luna® Novapak® Nucleodur® water / methanol water / acetonitrile water / methanol / acetonitrile acetonitrile / water / acetic acid acetic acid / acetonitrile Mobil phase formic acid / acetonitrile formic acid / water / acetonitrile ammonium / water / acetonitrile ammonium acetate / methanol Other (specify) TEST MATERIAL: U1111-1A and U1111-2A (confirmatory) RAL’s IN BOVINE URINE - incurred 2011, 1st round PAGINA 3 di 5 REVISIONE DATA DELLA REVISIONE N. 0 03/01/2011 The data of your analyses will be preserved for 5 years and then will be destroyed. D:\106745372.doc DOCUMENTO AGGIORNATO IL 01/03/11 Progetto Trieste 2011, 1st round, Veterinary Drug Residues Proficiency Testing Service by Test Veritas S.r.l. LABORATORY: … x<5 5<x<6 6 < x < 6.5 x < 0.2 0.2 < x < 0.3 0.3 < x < 0.4 ANALYST: … HPLC pH of mobile phase 6.5 < x < 7 x>7 Other (specify) Flow rate (ml/min) 0.4 < x < 0.5 x > 0.5 Other (specify) Post column reagent ... (specify) 5 < x < 10 10 < x < 20 20 < x < 30 Injection volume (l) 30 < x < 40 40 < x < 50 Other (specify) UV(nm) … (specify) GC methodology GC Capillary column length (m) Other (specify) 25 30 0.25 CP-SIL 8 CB/MS DB-1MS DB-5MS HP-5MS J&W 1 2 240 250 Splitless Pulsed splitless 80-300 80-320 95-295 Film thickness (m) Other (specify) Cromatographyc column Perking Elmer Elite 5MS OPTIMA-5-MS WCOT Fused silica Zebron® ZB-1 Other (specify) Injection volume (l) 4 Other (specify) Injection temperature (°C) 280 Other (specify) Injection procedure Split Other (specify) Oven temperature (°C) 120-130 120-300 Other (specify) TEST MATERIAL: U1111-1A and U1111-2A (confirmatory) RAL’s IN BOVINE URINE - incurred 2011, 1st round PAGINA 4 di 5 REVISIONE DATA DELLA REVISIONE N. 0 03/01/2011 The data of your analyses will be preserved for 5 years and then will be destroyed. D:\106745372.doc DOCUMENTO AGGIORNATO IL 01/03/11 Progetto Trieste 2011, 1st round, Veterinary Drug Residues Proficiency Testing Service by Test Veritas S.r.l. LABORATORY: … ANALYST: … Number of replicates (1 replicates = 1 extracion) 1 2 Number of extraction Other (specify) Recovery (HPLC and GC) Internal standard Spiked sample In-house Reference Material (RM) Recovery calculated by Matrix matched calibration Other (specify) Quality (HPLC and GC) Quality control implemented Control chart with in-house Reference Material (RM) Control chart with Certified Reference Material (CRM) Regular partecipation to proficency test (PT) Blank sample Duplicate analyses Spiked sample Other (specify) Reference (HPLC and GC) Internal method PAGINA 5 di 5 Reference Other (specify) REVISIONE DATA DELLA REVISIONE N. 0 03/01/2011 The data of your analyses will be preserved for 5 years and then will be destroyed. D:\106745372.doc DOCUMENTO AGGIORNATO IL 01/03/11