Naturalite(TM) Skylight Systems Oldcastle Glass® Engineered Products 750 Airport Road, P.O. Box 629 Terrell, TX 75160 (800) 527-4018 (972) 551-6400 fax: (972) 551-6420 This MANU-SPEC(TM) utilizes the Construction Specifications Institute (CSI) Manual of Practice, including MasterFormat(c), SectionFormat(c) and PageFormat(c). A MANU-SPEC is a manufacturer specific proprietary product specification using the proprietary method of specifying applicable to project specifications and master guide specifications. Optional text indicated by brackets []; delete optional text in final copy of specification. This MANU-SPEC specifies plastic unit skylights, as manufactured by Naturalite(TM) Skylights Systems, Oldcastle Glass® Engineered Products. Revise MANU-SPEC section number and title below to suit project requirements, specification practices and section content. Refer to CSI MasterFormat for other section numbers and titles. SECTION 08620 UNIT SKYLIGHTS (PLASTIC UNIT SKYLIGHTS) PART 1 - GENERAL 1.01 SUMMARY A. The work of this Section includes unit skylights. Note: Edit paragraph below for type of unit skylights to suit project requirements. Types: Types of unit skylights include: Curb-mounted skylights. Insulated curb skylights - double wall. Insulated curb skylights - single wall with a wood nailer. Insulated curb skylights - single wall, wood nailer, with removable counter flashing Ridge type skylights. Circular skylights. In-Tandem skylights. Cluster skylights. Vertex™ curb-mounted skylights. Vertex™ self-flashing skylights. Vertex2™ curb-mounted skylights. Vertex2™ self-flashing skylights Continuous Vaulted non-thermalized skylights Continuous Vaulted thermalized skylights Versalite™ Pre-glazed skylights. Versaridge™ Pre-glazed skylights. Tubular skylights. Hurricane Resistant skylights (curb mount). Hurricane Resistant skylights (self-flashing). A. Specifier Note: Revise paragraph below to suit project requirements. Add section numbers and titles per CSI Master-Format and specifier’s practice. B. Related Sections: Section(s) related to this section include: 1. 2. 3. 4. 5. Built-Up Bituminous Roofing: Division 7 Built-Up Roofing Sections. Modified Bituminous Sheet Roofing: Division 7 Modified Bituminous Roofing Sections. Single Ply Membrane Roofing: Division 7 Single Ply Roofing Sections. Flashing and Sheet Metal: Division 7 Flashing and Sheet Metal Section. Sheet Metal Roofing: Division 7 Sheet Metal Roof Section. Specifier Note: Article below may be omitted when specifying manufacturer's proprietary products and recommended installation. Retain Reference Article when specifying products and installation by an industry reference standard. If retained, list standard(s) referenced in this section. Indicate issuing authority name, acronym, standard designation and title. Establish policy for indicating edition date of standard referenced. Conditions of the Contract or Division 1 References Section may establish the edition date of standards. This article does not require compliance with standard, but is merely a listing of references used. Article below should list only those industry standards referenced in this section. 1.02 REFERENCES A. General: Standards listed by reference, including revisions by issuing authority, form a part of this specification section to extent indicated. Standards listed are identified by issuing authority, authority abbreviation, designation number, title or other designation established by issuing authority. Standards subsequently referenced herein are referred to by issuing authority abbreviation and standard designation. B. Aluminum Association (AA): 1. C. Specifications for Aluminum Structures. American Architectural Manufacturers Association (AAMA): 1. 2603-98 Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels. 2. 2604-98 Voluntary Specification for High Performance Organic Coatings on Architectural Extrusions and Panels. 3. 611-98 Specification for Anodized Architectural Aluminum. D. American Society for Testing and Materials, ASTM: D4802 Specification for Poly (Methyl Methacrylate) Acrylic Plastic Sheet. ASTM E283 Test Method for Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors. ASTM E330 Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference. E331 Test Method for Water Penetration of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference. E. National Roofing Contractors Association (NRCA): 1. Roofing and Waterproofing Manual. Specifier Note: Article below should be restricted to statements describing design or performance requirements and functional (not dimensional) tolerances of a complete system. Limit descriptions to composite and operational properties to extent necessary to link multiple components of a system, and to interface with other systems. 1.03 SYSTEM DESCRIPTION A. Performance Requirements: Provide roof accessories which have been manufactured, fabricated and installed to withstand loads from [Specify code/standard reference.] and to maintain [Specify performance criteria.] performance criteria stated by manufacturer without defects, damage or failure. B. Unit Skylight Performance Requirements: Specifier Note: Edit Performance Requirements paragraph below for loads to suit project requirements. Roof accessories are commonly used in low-rise construction where roof elevations do not exceed 60 feet above grade. Plastic glazing materials are not designed to support live loads or concentrated impact type loads. "Risk of fall" label is applied to each dome to warn of potential danger. (1) Performance Requirements: Referenced standards establish the level of quality of unit skylights available from quality manufacturers conforming to industry standards. (2) Condensation: Under certain conditions of high humidity and/or large inside to outside temperature differentials, condensation may occur on the aluminum framing and plastic glazing material. Thermally broken frames can be specified to help control compensation on aluminum framing. Double glazing will usually reduce the occurrence of condensation on the plastic, but will not totally eliminate it. The condensation that forms between the double layers of plastic will normally dissipate as the airspace is heated by the sun. Sealed domes are more resistant to the formation of condensation and will reduce accumulation of dust and foreign matter. Sealed domes are available for most dome glazed unit skylights at additional cost. Specifier Note: Edit paragraph below. Specify values, minimum 20 psf recommended. 1. Design framing and dome infill assembly to support the following load requirements: a. b. load. [30] [40]-psf snow load plus dead load. [30] [40]-psf negative wind or uplift load plus dead 2. Fabrication and installation of unit skylights shall comply with governing building code. Specifier Note: Article below includes submittal of relevant data to be furnished by Contractor either before, during, or after construction. Coordinate this article with Architect's and Contractor's duties and responsibilities in Conditions of the Contract and Division 1 Submittal Procedures Section. 1.04 SUBMITTALS A. General: Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal Procedures Section. B. Product Data: Submit product data, for specified products. C. Shop Drawings: Submit shop drawings showing layout, profiles, and product components, including anchorage, accessories, finishes and colors. 1. Submit shop drawings for approval prior to fabrication. Include details of framing members, glazing materials where applicable, sealants, fasteners, anchors and thicknesses and types of formed flashing and closures. D. Samples: Submit selection and verification samples for finishes, colors and textures. 1. Glazing Samples: Submit a verification sample of plastic glazing material in specified color. 2. Finish Samples: Submit a verification sample of aluminum finish in specified color. E. Quality Assurance Submittlas: Submit the following: 1. Test Reports: Certified test reports showing compliance with specified performance characteristics and physical properties. 2. Certificates: Product certificates signed by manufacturer certifying materials comply with specified performance characteristics and criteria, and physical requirements 3. Manufacturer’s Instructions: Manufacturer’s installation instructions. 4. Specifier Note: Coordinate paragraph below with Part 3 Field Quality Requirements Article herein. Retain or delete as applicable. 5. Manufacturer’s Field Reports: Manufacturer’s field reports specified herein. F. Closeout Submittals: Submit the following: 1. Operation and Maintenance Data: Operation and maintenance data for installed products in accordance with Division 1 Closeout Submittals (Maintenance Data and Operation Data) Section. Include methods for maintaining installed products, and precautions against cleaning materials and methods detrimental to finishes and performance. 2. Warranty: Warranty documents specified herein. Specifier Note: Article below should include prerequisites, standards, limitations and criteria which establish an overall level of quality for products and workmanship for this section. Coordinate below article with Division 1 Quality Assurance Section. 1.05 A. QUALITY ASSURANCE Qualifications: Installer Qualifications: Installer experienced in performing work of this section who has specialized in installation of work similar to that required for this project. Installer: Unit skylights shall be installed by workmen with a minimum of 2 years experience in installation of similar units. Manufacturer Qualifications: Manufacturer capable of providing field service representation during construction, approving acceptable installer and approving application method. Manufacturer: Unit skylights shall be manufactured by a firm with a minimum of 10 years experience in the fabrication and installation of plastic unit skylights. Manufacturers proposed for use, which are not named in this Section, shall submit evidence of ability to meet performance and fabrication requirements specified not less than 10 days prior to bid date, and shall include a list of projects of similar design and complexity completed within the past five years. Specifier Note: Paragraph below should list obligations for compliance with specific code requirements particular to this section. General statements to comply with a particular code are typically addressed in Conditions of the Contract and Division 1 Regulatory Requirements Section. Repetitive statements should be avoided. B. Regulatory Requirements: [Specify applicable requirements of regulatory agencies] Specifier Note: Retain paragraph below for erected assemblies (either onsite or offsite) required for review of construction, coordination of work of several sections, testing, or observation of operation. Mock-ups, when accepted or approved, establish standards by which work will be judged. Coordinate below with Division 1 Quality Control (Mock-Up Requirements) Section. Specifier Note: Article below should include special and unique requirements. Coordinate article below with Division 1 Product Requirements Section. 1.06 DELIVERY, STORAGE & HANDLING A. General: Comply with Division 1 Product Requirements Sections. B. Ordering: Comply with manufacturer's ordering instructions and lead time requirements to avoid construction delays. C. Delivery: Deliver materials in manufacturer's original, unopened, undamaged containers with identification labels intact. Sequence deliveries to avoid delays, but minimize on site storage. D. Storage and Protection: Store materials protected from exposure to harmful weather conditions and at temperature and humidity conditions recommended by manufacturer. 1. Protect from damage from sunlight, weather, excessive temperatures and construction operations. 1.07 A. PROJECT CONDITIONS Field Measurements: Verify actual measurements/openings by field measurements before fabrication; show recorded measurements on shop drawings. Coordinate field measurements and fabrication schedule with construction progress to avoid construction delays. 1. Measurements: Take accurate field measurements before fabrication. Do not delay job progress; allow for field tolerances if taking field measurements before fabrication is not possible. Specifier Note: Coordinate article below with Conditions of the Contract and with Division 1 Closeout Submittals (Warranty) Section. 1.08 A. WARRANTY Project Warranty: Refer to Conditions of the Contract for project warranty provisions. Specifier Note: Coordinate paragraph below with manufacturer's warranty requirements. Manufacturer offers the Following: Plastic Unit Skylight Warranty: Provide written five-year warranty signed by manufacturer, agreeing to repair or replace work which exhibits defects in materials or workmanship and guaranteeing weathertight and leak free performance. "Defects" is defined as uncontrolled leakage of water and abnormal aging or deterioration. B. Manufacturer’s Warranty: Provide written warranty signed by manufacturer, agreeing to repair or replace work which exhibits defects in materials or workmanship and guaranteeing weather tight and leak free performance. "Defects" is defined as uncontrolled leakage of water and abnormal aging or deterioration. 1. Skylight Warranty: Provide written warranty signed by manufacturer, agreeing to repair or replace work, which exhibits defects in materials or workmanship and guaranteeing weather tight, and leak free performance. "Defects" is defined as uncontrolled leakage of water and abnormal aging or deterioration. 2. Warranty Period: 5 years commencing on date of invoice. C. Finish Warranty: Provide written warranty signed by manufacturer and finisher, agreeing to repair or replace work that exhibits defects in finish. "Defects" is defined as peeling, chipping, chalking, fading, abnormal aging or deterioration, and failure to perform as required. 1. Warranty Period for Anodized Finish: One year from date of application for film integrity. 2. Warranty Period for Baked Enamel Finish: One year from date of application for film integrity. 3. Warranty Period for Fluoropolymer Finish: Five years from date of application for color and film integrity. PART 2 - PRODUCTS Specifier Note: Retain article below for proprietary method specification. Add product attributes, performance characteristics, material standards, and descriptions as applicable. Use of such phrases as "or equal" or "or approved equal," or similar phrases may cause ambiguity in specifications. Such phrases require verification (procedural, legal and regulatory) and assignment of responsibility for determining "or equal" products. 2.01 A. B. UNIT SKYLIGHTS Manufacturer: Naturalite Skylight Systems, Oldcastle Glass® Engineered Products. 1. Specifier Note: Paragraph below is an addition to CSI SectionFormat and a supplement to MANU-SPEC. Retain or delete paragraph below per project requirements and specifier's practice. 1. Contact: P.O. Box 629, 750 Airport Road, Terrell, TX 75160; Telephone: (800) 527-4018, (972) 551-6400; Fax (972) 551-6420 Proprietary Product(s)/System(s): Naturalite Plastic Unit Skylights 1. Materials: For each type of material required for the work of this Section, provide primary materials which are the products of one manufacturer. Provide secondary materials which are acceptable to the manufacturers of the primary materials. Specifier Note: Edit article below to suit project requirements. If substitutions are permitted, edit text below. Add text to refer to Division 1 Project Requirements (Product Substitutions Procedures) Section. 2.02 A. 2.03 PRODUCT SUBSTITUTIONS Substitutions: No substitutions permitted. MANUFACTURED UNITS Specifier Note: Edit paragraphs below. Select options applicable for project and delete options not required. (1) Typical glazing is acrylic and can be provided colorless, or in white, bronze, or grey colors. Single and double dome units are available. Double domes are recommended for energy conservation. Acrylic is the most common and economical material. Polycarbonate may be required for greater impact resistance or to meet some fire code requirements. Refer to the local building code for acceptable types and possible square foot area restrictions. Do not specify abrasion resistant acrylic or polycarbonate plastic glazing materials for use in domes in roof accessories. Sheet materials with abrasion resistant coatings should not be thermoformed for use in domes. (2) Finishes: Aluminum framing components are normally supplied in a natural mill finish. For more information and costs regarding architectural finishes, contact your nearest representative. A. Curb-Mounted Skylights: Factory assembled units consisting of plastic dome, 0.062" extruded aluminum frame and 0.062" extruded aluminum dome retaining angle. Skylight frame shall have an integral condensate gutter with weep slots. Weep slots shall be protected from weather and air-borne debris. Curb frame shall be predrilled for anchorage to curbs. 1. Type: [Model NL single dome] [Model NLDD double dome] [Model PNL pyramid single dome] [Model PNLDD pyramid double dome] [Model NTL thermalized sealed double dome] [Model PNTL thermalized sealed pyramid double dome] 2. Glazing: Acrylic plastic glazing 3. Outer [Single] Dome Color: [Colorless] [White # 2447] [Bronze # 2412] [Gray # 2064]. 4. Inner Dome Color: [Colorless] [White # 2447]. 5. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 6. Condensation Control: [Non-thermalized type shall have sufficient drainage slots to carry all moisture to the outside.] [Thermalized type shall have poured and debridged polyurethane thermal break; corners shall be factory sealed]. 7. Size: [Insert outside curb dimensions here if not indicated on drawings]. 8. Performance Minimums: Air Infiltration per ASTM E283 shall be < .01 CFM/ Cu. Ft. @ 6.25-psf negative pressure. Water Penetration per ASTM E331 shall pass at a negative pressure of 15-psf. These units are designed for built up roof applications B. Insulated Curb Skylights: Factory assembled self-flashing units consisting of plastic domes, 0.062" extruded aluminum curb frame, 0.062" extruded aluminum retaining angle, double wall insulated curb. Skylight frame shall have an integral condensate gutter with weep slots. Weep slots shall be protected from weather and air-borne debris. The curb shall have a 3" roof flange and house a 3/4" layer of insulation. Curbs shall be thermally broken. 1. Type: [Model NA single dome] [Model PNA pyramid single dome] [Model NADD double dome] [Model PNADD pyramid double dome] [Model NTLA thermalized sealed double dome] [Model PNTLA thermalized sealed pyramid double dome]. 2. Curb Height: [9"] [12"]. 3. Glazing: Acrylic plastic glazing. 4. Outer [Single] Dome Color: [Colorless] [White # 2447] [Bronze # 2412] [Gray # 2064]. 5. Inner Dome Color: [Colorless] [White # 2447]. 6. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 7. Condensation Control: [Non-thermalized type shall have sufficient drainage slots to carry all moisture to the outside.] [Thermalized type shall have poured and debridged polyurethane thermal break; corners shall be factory sealed.] 8. Size: [Insert inside curb dimensions here if not indicated on drawings]. 9. Performance Minimums: Air Infiltration per ASTM E283 shall be < .01 CFM/ Cu. Ft. @ 6.25-psf negative pressure. Water Penetration per ASTM E331 shall pass at a negative pressure of 15-psf. C. Plastic Dome Skylights with NSC Curb: Factory assembled units, each consisting of a plastic dome. The 0.062” extruded aluminum frame shall have an integral condensate gutter and sufficient drainage slots to carry all moisture to the outside. The curb shall consist of an aluminum wall, 1" x 4" treated wood nailer and 3/4" thick polyisocyanurate insulation (FEO spec. HH-I-1972/2 class 2) adhered to metal curb. Units are to be designed with removable tops for installation of roofing and then reattachment of the tops. 1. Type: [Model NSC Single Dome] [Model NSCDD Double Dome] [Model PNSC Pyramid Single Dome] [Model PNSCADD Pyramid Double Dome] [Model NSCTL Thermalized Double Dome] [Model PNSCTL Pyramid Double Dome]. 2. Curb Height: [9”] [12”] 3. Glazing: Acrylic plastic glazing 4. Outer [Single] Dome Color: [Colorless] [White # 2447] [Bronze # 2412] [Gray # 2064]. 5. Inner Dome Color: [Colorless] [White # 2447] 6. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 7. Condensation Control: [Non-thermalized type shall have sufficient drainage slots to carry all moisture to the outside.] [Thermalized type shall have poured and debridged polyurethane thermal break without weep holes; corners shall be factory sealed.] 8. Size: [Insert inside curb dimensions here if not indicated on drawings]. 9. These units are designed for single ply roof applications D. Plastic Dome Skylights with SFA Curb: Factory assembled units, each consisting of a plastic dome. The 0.062” extruded aluminum frame shall have an integral condensate gutter and sufficient drainage slots to carry all moisture to the outside. The curb shall consist of an aluminum wall, 1" x 4" treated wood nailer and 3/4" thick polyisocyanurate insulation (FEO spec. HH-I-1972/2 class 2) adhered to metal curb. Curbs shall be supplied with .062" extruded aluminum cap flashing and snap in place corner covers. 1. Type: [Model SFA Single Dome] [Model SFADD Double Dome] [Model PSFA Pyramid Single Dome] [Model PSFADD Pyramid Double Dome]. 2. Curb Height: [9”] [12”] 3. Glazing: Acrylic plastic glazing 4. Outer [Single] Dome Color: [Colorless] [White # 2447] [Bronze # 2412] [Gray # 2064]. 5. Inner Dome Color: [Colorless] [White # 2447]. 6. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 7. Size: [Insert inside curb dimensions here if not indicated on drawings]. E. Ridge Type Skylights: Curb-mounted units consisting of plastic glazing, 0.062" extruded aluminum outer retainer, and 0.078" extruded aluminum frame and condensate gutter. Rafters shall be tubular extruded aluminum with manufacturer's standard glazing seals. Units shall have weep holes to carry all moisture to the outside. 1. Type: [Model RT single glazed] [Model RTDD double glazed]. 2. Glazing: [Acrylic] [Polycarbonate] plastic glazing. 3. Outer [Single] Glazing Color: [Acrylic: [Colorless] [White # 2447] [Bronze # 2412] [Gray # 2064]] [Polycarbonate: [Colorless] [White #4571] [Bronze # 2556]] 4. Inner Glazing Color: [Acrylic: [Colorless] [White # 2447]] [Polycarbonate: [Colorless] [White #4571]] 5. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 6. Size: [Insert dimensions here if not indicated on drawings]. F. Circular Skylights (C): Factory-assembled units, each consisting of plastic glazing, 0.062" extruded aluminum retaining channel, 0.032" aluminum curb walls, 3" mounting flange and condensate gutter. Units shall have weep holes to carry all moisture to the outside. 1. Type: [Model C single dome] [Model CDD double dome]. 2. Curb Height: [4"] [9"]. 3. Glazing: Acrylic plastic glazing 4. Outer [Single] Dome Color: [Colorless] [White # 2447] [Bronze # 2412] [Gray # 2064] 5. Inner Dome Color: [Colorless] [White # 2447]. 6. Frame Finish: Manufacturer's standard [mill finish] [polyester baked enamel color to be [white] or [bronze]]. 7. Size: [Insert inside curb dimensions here if not indicated on drawings]. G. In-Tandem Skylights (LIT): Curb-mounted units, each consisting of plastic glazing, 0.062" extruded aluminum retaining angle, 0.078" extruded aluminum frame and condensate gutter. Intermediate mullions shall be 0.080" extruded aluminum with manufacturer's standard glazing seals. Units shall have weep holes to carry all moisture to the outside. Support structure by others to be provided under all framing and mullions. 1. Type: [Model LIT single dome] [Model LIT-DD double dome] [Model PLIT pyramid single dome] [Model PLIT-DD pyramid double dome]. 2. Glazing: Acrylic plastic glazing 3. Outer [Single] Dome Color: [Colorless] [White # 2447] [Bronze # 2412] [Gray # 2064]. 4. Inner Dome Color: [Colorless] [White # 2447]. 5. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering]] 6. Size: [Insert outside curb dimensions here if not indicated on drawings]. H. Cluster Skylights (CLS): Curb mounted units, each consisting of plastic glazing, 0.094”extruded aluminum retaining angle, 0.093" extruded aluminum frame and condensate gutter. Main and cross gutters shall be 0.093" extruded aluminum with manufacturer's standard glazing seals. EPDM glazing seals required above and below all glazing. Units shall have baffled weep holes to control air infiltration and allow all moisture to the outside. Support structure, by others, must slope a minimum of 1/4" per foot in one direction. Support structure by others required at perimeter and all framing members parallel to the slope (main gutter). Cross gutters shall be self-supporting. (Note: at spans not to exceed 6’ at positive loads not to exceed 40-psf). Cross caps shall not rise above the glazing flange more than 3/16” so as not to inhibit the flow of water off the unit. Independent certified testing required indicating performance levels listed below. 1. Air Infiltration per ASTM E 283: .1 CFM/ Sq. Ft. allowable at a negative pressure of 6.24-psf. Water Penetration per ASTM E 331: No uncontrolled water at a negative pressure of 10-psf. 2. Type: [Model CLS single dome] [Model CLSDD double dome] [Model PCLS pyramid single dome] [Model PCLSDD pyramid double dome]. 3. Glazing: Acrylic plastic glazing 4. Outer [Single] Dome Color: [Colorless] [White # 2447] [Bronze # 2412] [Gray # 2064]. 5. Inner Dome Color: [Colorless] [White # 2447]. 6. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 7. Size: [Insert outside curb dimensions here if not indicated on drawings]. I. VertexTM Curb Mount Skylights (PTLP): Skylights shall be factory-assembled units, each consisting of two sealed pyramid domes of polycarbonate. They shall have a .078" extruded aluminum frame with polyurethane thermal break to prevent condensation on interior portions of aluminum frame and .062" extruded aluminum dome retaining angle. The skylights are to be completely sealed with neoprene gaskets between domes and frame members, with no weep holes, eliminating air infiltration and ex-filtration. Uniform design load capability of composite dome and frame to meet or exceeds 40-psf snow load. No breakage or disengagement of dome from the frame shall occur upon impact of up to 1,000 ft. lbs. 1. Type: Model PTLP. 2. Glazing: Lexan XL10 polycarbonate glazing. 3. Outer Dome Color: [Colorless] [White #4571] [Bronze # 2556] 4. Inner Dome Color: [Colorless] [White #4571] 5. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2-coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 6. Size: [Insert outside curb dimensions here if not indicated on drawings]. J. VertexTM Self Flashing Skylights (PTLAP): Skylights shall be factory-assembled units, each consisting of two sealed pyramid domes of polycarbonate. They shall have a .078" extruded aluminum frame with polyurethane thermal break to prevent condensation on interior portions of aluminum frame and .062" extruded aluminum dome retaining angle. The skylights are to be completely sealed with neoprene gaskets between domes and frame members, with no weep holes, eliminating air infiltration and ex-filtration. Insulated curbs shall be constructed with an aluminum inner and outer wall isolated at the top and bottom by PVC thermal barriers. Insulation material between walls is to be polyisocyanurate. Uniform design load capability of composite dome and frame to meet or exceed 40-psf snow load. No breakage or disengagement of dome from the frame shall occur upon impact of up to 1000 ft. lbs. 1. Type: Model PTLAP. 2. Curb Height: [9”] [12”] 3. Glazing: Lexan XL10 polycarbonate glazing. 4. Outer Dome Color: [Colorless] [White #4571] [Bronze # 2556] 5. Inner Dome Color: [Colorless] [White #4571] 6. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2-coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 7. Size: [Insert inside curb dimensions here if not indicated on drawings]. K. Vertex2TM Curb-Mounted Skylights: Factory assembled units consisting of impact modified plastic dome, 0.062" extruded aluminum frame and 0.062" extruded aluminum dome retaining angle. Skylight frame shall have an integral condensate gutter with weep slots. Weep slots shall be protected from weather and air-borne debris. Curb frame shall be predrilled for anchorage to curbs. No breakage or disengagement of dome from frame shall occur upon impact of up to 1000 ft. lbs. 1. 2. 3. 4. 5. Type: [Model FNL single dome] [Model FNLDD double dome] [Model FPNL pyramid single dome] [Model FPNLDD pyramid double dome] [Model FNTL thermalized sealed double dome] [Model FPNTL thermalized sealed pyramid double dome] Glazing: Impact modified plastic glazing. Outer [Single] Dome Color: [Colorless] [White # 2447] Inner Dome Color: [Colorless] [White # 2447]. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2-coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 6. 7. 8. L. Condensation Control: [Non-thermalized type shall have sufficient drainage slots to carry all moisture to the outside.] [Thermalized type shall have poured and debridged polyurethane thermal break; corners shall be factory sealed.] Size: [Insert outside curb dimensions here if not indicated on drawings]. Performance Minimums: Air Infiltration per ASTM E283 shall be < .01 CFM/ Cu. Ft. @ 6.25-psf negative pressure. Water Penetration per ASTM E331 shall pass at a negative pressure of 15-psf. Vertex2TM Insulated Curb Skylights: Factory assembled self-flashing units consisting of impact modified plastic domes, 0.062" extruded aluminum curb frame, 0.062" extruded aluminum retaining angle, double wall insulated curb. Skylight frame shall have an integral condensate gutter with weep slots. Weep slots shall be protected from weather and air-borne debris. Insulated curbs shall be constructed with an aluminum inner and outer wall isolated at the top and bottom by PVC thermal barriers. Insulation material between walls is to be polyisocyanurate. No breakage or disengagement of dome from frame shall occur upon impact of up to 1000 ft. lbs. 1. Type: [Model FNA single dome] [Model FPNA pyramid single dome] [Model FNADD double dome] [Model FPNADD pyramid double dome] [Model FNTLA thermalized sealed double dome] [Model FPNTLA thermalized sealed pyramid double dome]. 2. Curb Height: [9"] [12"]. 3. Glazing: Impact modified plastic glazing. 4. Outer [Single] Dome Color: [Colorless] [White # 2447]. 5. Inner Dome Color: [Colorless] [White # 2447]. 6. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2-coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 7. Condensation Control: [Non-thermalized type shall have sufficient drainage slots to carry all moisture to the outside.] [Thermalized type shall have poured and debridged polyurethane thermal break; corners shall be factory sealed.] 8. Size: [Insert inside curb dimensions here if not indicated on drawings]. 9. Performance Minimums: Air Infiltration per ASTM E283 shall be < .01 CFM/ Cu. Ft. @ 6.25-psf negative pressure. Water Penetration per ASTM E331 shall pass at a negative pressure of 15-psf M. Continuous vaulted skylights non-thermalized: Curb-mounted units consisting of extruded aluminum frame. Sill members shall collect and weep water to the exterior. Factory slot sill members at anchor locations for thermal movement. Rafter members shall be spaced [4’0” on center for uniform snow load not exceeding 30-psf] [3’0” on center for uniform snow load not exceeding 40-psf]. All continuous gaskets above and below plastic glazing material shall be black EPDM. Factory-assemble units in sections not to exceed 20 lineal feet for outside curb spans of 87 inches or less. All units over 85 inches shall be shipped unassembled for access to anchors from roof level. Submit test report showing: systems performance when tested for Air Infiltration per ASTM E-283, 6.24-psf static water resistance when tested per ASTM E331, Structural Performance when tested to ASTM E-330. 1. 2. Type: [Model CV single glazed vault] [Model CVR single glazed ridge]. Ends: [Vertical] [Domed] [Wall Abutment]. 3. 4. 5. 6. N. Glazing: [Acrylic] [Lexan XL10 polycarbonate] plastic glazing. Glazing Color: [Acrylic: [Colorless] [White # 2447] [Bronze # 2412] [Gray # 2064]] [Lexan XL10 Polycarbonate: [Colorless] [White #4571] [Bronze # 2556]] Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2-coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] Size: [Insert outside curb dimensions here if not indicated on drawings]. Provide [standard] [custom] spacing and widths as indicated on the Drawings. Continuous vaulted skylights with thermalized frame: Curb-mounted units consisting of extruded aluminum frame with polyurethane thermal break to minimize condensation on interior portions of aluminum frame as shown on the drawings. Sill members shall collect and weep water infiltration that occurs on the exterior side of the thermal barrier to the outside, however weep holes shall not penetrate through the thermal barrier. Factory slot sill members at anchor locations for thermal movement. Rafter members shall be spaced [4’0” on center for uniform snow load not exceeding 30-psf] [3’0” on center for uniform snow load not exceeding 40-psf]. All continuous gaskets above and below plastic glazing material shall be black EPDM. Factory-assemble units in sections not to exceed 20 lineal feet for outside curb spans of 87 inches or less. All units over 85 inches shall be shipped unassembled for access to anchors from roof level. Submit test report showing: systems performance when tested for Air Infiltration per ASTM E-283, 6.24-psf static water resistance when tested per ASTM E331, Structural Performance when tested to ASTM E-330. 1. 2. 3. 4. 5. Type: [Model CVTL double glazed vault] [Model CVTLR double glazed ridge]. Ends: [Vertical] [Domed] [Wall Abutment]. Glazing: [Acrylic] [Lexan XL10 polycarbonate] plastic glazing. Outer Glazing Color: [Acrylic: [Colorless] [White # 2447] [Bronze # 2412] [Gray # 2064]] [Lexan XL10 Polycarbonate: [Colorless] [White #4571] [Bronze # 2556]] Inner Glazing Color: [Acrylic: [Colorless] [White # 2447]] [Polycarbonate: [Colorless] [White #4571]]. 6. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 7. Size: [Insert outside curb dimensions here if not indicated on drawings]. Provide [standard] [custom] spacing and widths as indicated on the Drawings. O. Versalite™ Pre-glazed skylights: Pyramid style skylights. Skylight framing members to be fabricated from 6063-T5 extruded aluminum. Include an integral gutter system to control water infiltration and condensation. Provide “Versalite” framing system that will collect and channel condensation and water infiltration to the exterior through weep holes. System shall be cap glazed and shall be secured with thermally broken glazing clips. Glazing system shall include a “positive stop” to control compression in the glazing rabbet. Apply cap seal at corner intersections. Provide continuous cushion below glazing materials with extruded, dense EPDM black rubber gasket with 60 plus or minus 5 Shore A durometer complying with ASTM C864. Provide continuous spacer above glazing materials with extruded, closed-cell, sponge EPDM black rubber gasket complying with ASTM C509. Fabricate gaskets of material to withstand one part per million ozone for 500 hours at 20 percent elongation at 100 degrees F when tested in accordance with ASTM D1149. 1. Type: [Model VLG glass skylight] [Model VLP polycarbonate skylight]. 2. Glazing: [Model VLG: Insulating glass 1” thick: Exterior lite: ¼” [clear] [tinted] heat-strengthened glass ½” air space Interior lite: ¼” laminated glass comprised of 2 plies of 1/8” clear [heatstrengthened] glass [Low E #3] with a 0.030” clear polyvinyl butyl interlayer.] [Model VLP: Polycarbonate 25mm [clear][white] multi-wall polycarbonate sheet]. 3. Framing System: Provide thermally broken framing system to include integral gutter to control water infiltration and condensation. System to be cap glazed with concealed fasteners. System to include a “positive” stop to control compression in the glazing rabbet. 4. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2-coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 5. Size: [Insert outside curb dimensions here if not indicated on drawings]. 6. Test Reports: Provide test reports showing allowable air infiltration not exceeding 0.5 CFM/ Sq. Ft. of total glazed surface when system is tested in accordance with ASTM E283 at a static pressure of 6.24-psf. Provide test reports showing no uncontrolled water leakage occurring when system is tested in accordance with ASTM E331 at a static pressure of 12psf. P. Versaridge™ Pre-glazed skylights: Ridge style skylights with vertical ends. Skylight framing members to be fabricated from 6063-T5 extruded aluminum. Include an integral gutter system to control water infiltration and condensation. Provide “Versaridge” framing system that will collect and channel condensation and water infiltration to the exterior through weep holes. System shall be cap glazed and shall be secured with thermally broken glazing clips. Glazing system shall include a “positive stop” to control compression in the glazing rabbet. Apply cap seal at corner intersections. Provide continuous cushion below glazing materials with extruded, dense EPDM black rubber gasket with 60 plus or minus 5 Shore A durometer complying with ASTM C864. Provide continuous spacer above glazing materials with extruded, closed-cell, sponge EPDM black rubber gasket complying with ASTM C509. Fabricate gaskets of material to withstand one part per million ozone for 500 hours at 20 percent elongation at 100 degrees F when tested in accordance with ASTM D1149. 1. Type: [Model VRG glass skylight] [Model VRP polycarbonate skylight]. 2. Glazing: [Model VRG: Insulating glass 1” thick: Exterior lite: ¼” [clear] [tinted] heat-strengthened glass ½” air space Interior lite: ¼” laminated glass comprised of 2 plies of 1/8” clear [heat- strengthened] glass [Low E #3] with a 0.030” clear polyvinyl butyl interlayer.] [Model VRP: Polycarbonate 25mm [clear][white] multi-wall polycarbonate sheet]. 3. Framing System: Provide thermally broken framing system to include integral gutter to control water infiltration and condensation. System to be cap glazed with concealed fasteners. System to include a “positive” stop to control compression in the glazing rabbet. 4. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2-coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 5. Size: [Insert outside curb dimensions here if not indicated on drawings]. 6. Test Reports: Provide test reports showing allowable air infiltration not exceeding 0.06 CFM/ Sq. Ft. of total glazed surface when system is tested in accordance with ASTM E283 at a static pressure of 6.24-psf. Provide test reports showing no uncontrolled water leakage occurring when system is tested in accordance with ASTM E331 at a static pressure of 12-psf. Q. Tubular Skylights: Light Collecting Aperture: Shall be a factory assembled self-flashing skylight comprised of a self flashing curb constructed with an aluminum inner and outer wall isolated at the top and bottom by PVC thermal barriers. The curb shall have a 3" roof flange and house a layer of polyisocyanurate insulation. The skylight frame shall be extruded aluminum with a polyurethane thermal break to prevent condensation on interior portions of aluminum frame and 0.062" extruded aluminum dome retaining angle, glazed with a polycarbonate dome, and sealed to a .030 thick radial lens film. [Optional: Curb mounted skylight, omit self flashing curb above.] Extension Shafts: The extension tubes shall be formed from .020 thick high reflective aluminum, having a specular reflectance of 95% and a total reflectance of 97%. Ceiling Diffuser: Shall be comprised of a .030 thick polycarbonate radial lens film that shall be sealed to the bottom of the bottom extender tube. The lens film shall contain optical quality circular prisms on one side and a smooth finish on the other. 1. Type: [Self Flashing Tubular][Curb Mount Tubular] 2. Glazing: Polycarbonate glazing, Radial Lens film. 3. Frame Finish: (Skylight frame and Retaining angle only) Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2-coat, 50% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 4. Condensation Control: Thermalized type skylight frame shall have poured and debridged polyurethane thermal break without weep holes; corners shall be factory sealed. 5. Size: [2 x 2 at Ceiling Grid or 4 x 4 at Ceiling Grid]. R. Hurricane Resistant Curb-Mounted Skylights: Factory assembled units consisting of impact resistant plastic glazing, 0.078" extruded aluminum frame and 0.062" min. extruded aluminum dome retaining angle. Skylight frame shall have an integral condensate gutter with weep holes. Units shall be approved by Miami-Dade County for Protocol PA 201 (Large Missile Impact), Protocol 203 (Cycle), and Protocol 202 (Air, Water, Structural) and bear a current NOA number. 1. 2. 3. 4. 5. Type: [Model HRL single dome] [Model HRLDD double dome] Glazing: Impact modified acrylic plastic glazing. Outer or [Single] Dome Color: [Colorless] [White # 2447]. Inner Dome Color: [Colorless] [White # 2447]. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2-coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 6. Condensation Control: Drainage slots to carry all moisture to the outside as described on the tested units. 7. Acceptance #: 04-0302.01 8. Size: Not to exceed 83” x 99” outside curb dimensions. S. Hurricane Resistant Self Flashing Skylights: Factory assembled self-flashing units consisting of impact resistant plastic glazing, 0.062" extruded aluminum curb frame, 0.062" min. extruded aluminum retaining angle, double wall insulated curb comprised of, 063” thick aluminum inner and outer wall, housing a ¾” thick rigid insulation. The curb shall have a 3" roof flange and house a 3/4" layer of polyisocyanurate insulation. Skylight frame shall have an integral condensate gutter with weep holes. Units shall be approved by Miami-Dade County for Protocol PA 201 (Large Missile Impact), Protocol 203 (Cycle), and Protocol 202 (Air, Water, Structural) and bear a current NOA number. Skylight frame and self-flashing curb shall have been tested as a complete unit 1. 2. 3. 4. 5. Type: [Model HRA single dome] [Model HRADD double dome] Glazing: Impact modified acrylic plastic glazing. Outer or [Single] Dome Color: [Colorless] [White # 2447]. Inner Dome Color: [Colorless] [White # 2447]. Frame Finish: Manufacturer's standard [mill finish] [A31 clear anodized coating complying with AAMA 611-98, 0.4-0.7 mil thick minimum] [A44 dark bronze anodized coating complying with AAMA 611-98, 0.7 mil thick minimum] [Fluoropolymer 2-coat, 70% Kynar 500/Hylar 5000 resin base coating complying with AAMA 2604-98, color to be [ ] as selected from manufacturers standard color offering] 6. Condensation Control: Drainage slots to carry all moisture to the outside as described on the tested units. 7. Acceptance #: 04-0302.01 8. Size: Not to exceed 80” x 96” inside curb dimensions. 2.04 ACCESSORIES A. Saf-T-Guard Fall Protection Screen: Fall protection screen shall be of welded wire construction using 5 gauge galvanized wire with a 4” x 4” grid pattern. Protective screens shall comply with OSHA General Industry Standards 1910.23(e)(8). B. Burglar Bars/Security Grill: Burglar Bars shall be ½” diameter steel bars at [8” x 8” O.C] [8” x 12” O.C.] [12” x 12” O.C.] with steel angle 1½” x 2” x 1/8” on 2 sides and are prime painted white. 2.05 A. 2.06 A. RELATED MATERIALS Related Materials: Refer to other sections listed in Related Section paragraph herein for related materials. SOURCE QUALITY Source Quality: Obtain unit skylights from a single manufacturer. PART 3 - EXECUTION Specifier Note: Article below is an addition to the CSI SectionFormat and a supplement to MANU-SPEC. Revise article below to suit project requirements and specifier's practice. 3.01 A. 3.02 A. MANUFACTURER'S INSTRUCTIONS Compliance: Comply with manufacturer's product data, including product technical bulletins, product catalog installation instructions and product carton instructions for installation. EXAMINATION Site Verification of Conditions: Verify substrate conditions, which have been previously installed under other sections, are acceptable for product installation in accordance with manufacturer's instructions. 1. Take field dimensions and examine conditions of substrates, supports, and other conditions under which work is to be performed and notify Contractor, in writing, of circumstances detrimental to proper completion of work. Do not proceed with work until unsatisfactory conditions are corrected. 3.03 A. PREPARATION Adjacent Surfaces Protection: Protect adjacent work areas and finish surfaces from damage during product installation. Specifier Note: Coordinate article below with manufacturer's recommended installation details and requirements. 3.04 A. INSTALLATION Unit Skylight Installation: 1. Match profiles, sizes and spacings indicated on approved shop drawings. 2. Coordinate installation with adjacent work such as roofing, sheet metal and other work to ensure creation of a complete weatherproof assembly. Anchor work securely to supporting structure, but allow for differential and thermal movement. 3. Isolate between aluminum and dissimilar metals with a protective coating or plastic strip to prevent electrolytic corrosion. B. Related Products Installation: Refer to other sections listed in Related Section paragraph herein for related products installation. Specifier Note: Coordinate article below with Division 1 Execution Requirements (Starting And Adjusting, Cleaning, and Protecting Installed Construction) Section. 3.05 FIELD QUALITY REQUIREMENTS A. 3.06 Site Tests (Installation and Post Installation Testing): [Specify applicable test requirements to be performed during and/or after product installation.] ADJUSTING A. Adjusting: After installation, remove shipping clips from components. Do not remove "risk-offall" labels from units. Touch-up and repair minor damage to eliminate all evidence of repair. Remove and replace work which cannot be satisfactorily repaired. Specifier Note: Coordinate article below with Division 1 Execution Requirements (Cleaning) Section. 3.07 A. CLEANING Cleaning: Remove temporary coverings and protection of adjacent work areas. Repair or replace damaged installed products. Clean installed products in accordance with manufacturer's instructions prior to owner's acceptance. Remove construction debris from project site and legally dispose of debris. 1. Clean all exposed surfaces including metal and glazing using non-abrasive materials and methods recommended by manufacturer of material or product being cleaned. Remove and replace work that cannot be successfully cleaned. 2. Reclean as necessary to prevent damage. Protect completed work from damage and deterioration and inspect immediately before final acceptance of project. Specifier Note: Coordinate article below with Division 1 Execution Requirements Section. 3.08 A. PROTECTION Protection: Protect installed product and finish surfaces from damage during construction. END OF SECTION 08620 Conditions of Use: Guide specifications must be modified for use on individual projects. Naturalite® Skylight Systems, its agents, and employees make no warranties express or implied by operation of law or otherwise made with respect to the cover sheet or specifications, including any implied warranties of merchantability or fitness for a particular purpose. © 2006 Naturalite® Skylight Systems. All Rights Reserved. A copyright license to reproduce this specification is hereby granted to non-manufacturing architects, specification writers, and designers.