Release Highlights for CAM350 Product Version 7.6 Release, December 2002 Copyright 1994-2002, DownStream Technologies, LLC Introduction to CAM350 Version 7.6 Version 7.6 is the follow-on update to Versions 7.0 and 7.5. Version 7.6 introduces the new Fast Array Module option allowing for both the PCB Fabricator and the PCB Designer to access standard panelization tools. Version 7.6 also updates the PCAD 2001 and PCAD 2002 CAD interface. Version 7.6 allows you to automate your sub-panel process with the Fast Array Module. You can create panel templates, which can be used and stored for reuse. You can populate panels in either an automatic stepping mode or use spreadsheet mode for total control. With the Fast Array Module in automatic mode, you pick the assembly panel size, and we populate with best utilization based on your spacing requirements. You can also use the spreadsheet mode, which allows placing and rotation of individual boards to meet your specific subpanel requirements. With Version 7.5 from DownStream Technologies, the FabFactory product line and the CAM350 product line are merged back into a single product line which will retain the CAM350 name. The focus of DownStream Technologies remains to provide leading edge CAM tools to both the PCB Design and PCB Fabrication markets. However, this merger of the two product lines provides all customers with access to powerful modules previously only available in the high-end FabFactory product line. This allows both the PCB Fabricator and the PCB Designer to access tools for DFF analysis, MRC and Quote Agents, Advanced Panel and NC Editors, ODB++ Input and Output, and many other features. Version 7.5 also contains a number of software corrections made since the release of Version 7.0. Version 7.0 was the first major release of CAM350 with special focus specifically to the Printed Circuit Board Fabricators. The ODB++ Interface and Panelization Editor are the most significant fabrication technologies to be applied within 7.x. However, Version 7.0 was focused on more than just the PCB Fabricators. The Latium architecture, representing a significant technological breakthrough in EDA system architecture, was integrated into this release. Through Latium all users benefit from 10 times, to as much as 100 times, performance improvement in critical design and manufacturing analysis areas. Acid trap detection processes that use to take minutes now take seconds. Sliver detections that took hours now run in seconds as well. Latium was also applied to some of the key data optimization functions, like Netlist Extraction, in order to help increase throughput and reduce overall processing times. A secondary benefit to migrating to the Latium architecture is accuracy. Prior to using Latium the DFF Audits where processed using a “Raster” technique, which meant that the user had to define a resolution. Ultimately the accuracy of the test that was being performed was then bound by the resolution the user picked – if they didn’t choose a tight enough resolution the check would fail to find all the problems that might exist on the PCB. Since Latium is a “Contour” based environment it has eliminated the need for any raster processing and has improved the accuracy by as much as 50 times, since we now have an exact edge representation of all the objects within a PCB. Listed below you will find the Version 7.6 CAM350 Configuration Matrix, and the Transition Map for mapping customers from CAM350/FabFactory Version 7.0 configurations to CAM350 Version 7.6 configurations. This updated transition map from DownStream Technologies is for a product line with a long and bright future ahead of it. DownStream Technologies CAM350 Version 7.6 Design Family Configurations CAM350 Fabrication Modules C350-750 C350-500 C350-450 C350-255 C350-100 C350-050 Imp ort Information Exp ort M odification Op timization M RC/DRC DirectCAD Interface In Basic NC Editor Quote Agent Fast Array M odule DXF Interface DFF Audit M RC Agent M acro Debugger Panel Editor Advanced NC Editor ODB++ Imp ort ODB++ Exp ort DirectCAD Interface Out Reverse Engineering Fly ing Probe Editor Bed of Nails Editor Camtek AOI X X X X X X X X X X X X X X X X X X X X X X Opt. X X X X X X X X X X X X X X X X X X X X Opt. Opt. Opt. X X X X X X X X X X X X X X X X Opt. Opt. Opt. Opt. Opt. Opt. Opt. X X X X X X X X X X X X X X Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. X X X X X X X X X Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. X X Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Mapping for CAM350 Customers CAM350 V7.5 Maps to CAM350 V7.6 Configuration Configuration CAM350-250 CAM350-255 plus: Fast Array Module Mapping for CAM350 Customers CAM350 V7.0 Maps to CAM350 V7.6 Configuration Configuration CAM350-050 CAM350-100 CAM350-250 CAM350-500 DownStream Technologies CAM350-050 CAM350-100 plus: Quote Agent CAM350-255 plus: Quote Agent Fast Array Module Macro Debugger CAM350-500 plus: Panel Editor Advanced NC-Editor Page 2 Mapping for FabFactory Customers FabFactory V7.0 Maps to CAM350 V7.6 Configuration Configuration FF-050 FF-100 FF-125 CAM350-050 CAM350-100 plus: Export Direct CAD Interface (Import) Basic NC Editor CAM350-255 plus: Quote Agent DFF Audit DXF Interface Direct CAD Interface (Import) Fast Array Module FF-250 FF-500 DownStream Technologies CAM350-450 plus: Quote Agent MRC Agent Direct CAD Interface (Import) CAM350-750 plus: Reverse Engineering Direct CAD Interface (Import) Page 3 Customer Reported Software Corrections Some of the customer reported issues were addressed in CAM350 7.6 include: IMPORT ----9971,10286,10905,11035 – AccelEDA (PCAD) files for PCAD 2001 version files are now supported. 10792,10929 – The ODB++ Import command no longer drops drills for certain designs. 10818 – The Gerber Import command no longer drops voids for certain cutline polygons. 10836 – The Gerber Import command no longer fails for designs with certain polygon definitions with arcs. 10921 – The Gerber Import command performance is improved for cutline polygon import. 10975 – The PADS Import command now correctly handles certain designs with certain padstack definitions. ANALYSIS ----10762 – Pad to Solder Mask DRC check displays a negative clearance to report the annular ring size for solder mask that overlaps a pad. UTILITIES ----10906 – The Composite To Layer command no longer fails for designs with certain polygon definitions. 10909 – Remove Redundant Data command no longer removes certain thermals for certain positive plane designs. 10950 – The Camtek AOI interface properly translates certain polygon outlines for certain designs with positive planes. 10961 - Netlist extract for MCM designs no longer drops insulator layer pads (10443,10751,11032) 10976 – The Camtek properly works for certain Camtek.INI files. 11022 - Netlist extract now properly merges nets for MCM designs PRINTING ----10708 – Printing to a file can now be reset to another printer properly. INFORMATION ----11026 – Measuring distance between objects and an asymmetric custom aperture is correct. PANEL EDITOR ----10864 – Deleting Pinholes now works properly for the Setup dialog in the Panel Editor. FLYING PROBE EDITOR ----10874 – SMT pads are now properly totaled for Info->Report->Test Points output. NC EDITOR ----10962 - Gerber to Mill now longer fails for certain designs. EXPORT ----10948 - IPCD356A output is correct for drills with size greater than 4.2 mm. 10969 – The Mill Path is no longer incorrect after exporting Mill Data. P-CAD 2001 and P-CAD 2002 are registered trademarks of Accel Technologies, Inc. DownStream Technologies Page 4